| Sl. No. | Item Description |
| 1 | M & L Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out In Hard/dense soil. Complete all as specified and directed by Engineer-in-charge. |
| 2 | Excavating in trenches, by mechanical means(hydraulic excavator) n exc 1.5 m wide and n exc 1.5 m in depth; for footing, Plinth Beam & Dwarf Wall, etc. n exc 10 sq m on plan and getting out in Hard/dense soil. Completed all as specified and directed by Engineer-in-charge. |
| 3 | Excavating in trenches, by mechanical means(hydraulic excavator) exc 1.5 m wide and n exc 3.0 m in depth; for footing, Plinth Beam & Dwarf Wall, etc. n exc 10 sq m on plan and getting out in Hard/dense soil. Completed all as specified and directed by Engineer-in-charge. |
| 4 | M & L Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface Completed all as specified and directed by Engineer-in-charge. |
| 5 | M & L Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface. Completed all as specified and directed by Engineer-in-charge. Note:- Area of the sub structure in contact with backfill to be measured. |
| 6 | M & L Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall Completed all as specified and directed by Engineer-in-charge. |
| 7 | M & L Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area Completed all as specified and directed by Engineer-in-charge. |
| 8 | M & L Cement concrete in foundations, filling and mass concrete 1:4:8 using 40 mm graded aggregate (For Foundation) Completed all as specified and directed by Engineer-in-charge. |
| 9 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in Hard/dense soil. Completed all as specified and directed by Engineer-in-charge. |
| 10 | Removing excavated material in Hard/dense Soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point Completed all as specified and directed by Engineer-in-charge. |
| 11 | M & L RCC- M-30 (Design Mix) using 20mm graded aggregate For Footing and plinth beams. Completed all as specified and directed by Engineer-in-charge. |
| 12 | M & L RCC- M30 (Design Mix) using 20mm graded aggregate for Column complete all as specified and directed |
| 13 | M & L RCC- M30 (Design Mix) using 20mm graded aggregate for beams and lintels Completed all as specified and directed by Engineer-in-charge. |
| 14 | M & L RCC- M30 (Design Mix) using 20mm graded aggregatefor RCC Slab Completed all as specified and directed by Engineer-in-charge. |
| 15 | M & L RCC- M30 (Design Mix) using 20mm graded aggregatefor RCC parapet wall/drops/RCC Chajjas Completed all as specified and directed by Engineer-in-charge. |
| 16 | M & L RCC- M30 (Design Mix) using 20mm graded aggregate) for Chullah hoods; stairways(except spiral staircases)including steps (square or spandril), string pieces, carriages, etc., complete, anysection straight or winding, butexcluding landings; RCCwater tanks upto 1500 litres Completed all as specified and directed by Engineer-in-charge. |
| 17 | S & F TMT bars 10mm dia & over of Grade Fe 500 incl cutting, bending, binding & placing in position with binding wirefor footings Slab beams roof slab etc complete al as specified and directed Completed all as specified and directed by Engineer-in-charge. |
| 18 | All as per item No 17 but 5 to 10mm dia in stirrups, spacers & binders. Completed all as specified and directed by Engineer-in-charge. |
| 19 | M & L Form workfor rough finished surfaces of concrete measured flat for For Footing. Completed all as specified and directed by Engineer-in-charge. |
| 20 | M & L Form workfor rough finished surfaces of concrete measured flat for Column. Completed all as specified and directed by Engineer-in-charge. |
| 21 | M & L use & waste Form workfor rough finished surfaces of concrete measured flat for Plinth Beam. Completed all as specified and directed by Engineer-in-charge. |
| 22 | M & L use & waste Form workfor rough finished surfaces of concrete measured flat for RCCbeams sides and soffits Completed all as specified and directed by Engineer-in-charge. |
| 23 | M & L use & waste Form workfor rough finished surfaces of concrete measured flat for RCCSlab Completed all as specified and directed by Engineer-in-charge. |
| 24 | M & L use & waste Formwork to spiral staircaseof square/ rectangular with sloping or stepped soffits, including risers and stringers(excluding landing) Completed all as specified and directed by Engineer-in-charge. |
| 25 | M & L use & waste Form workfor rough finished surfaces of concrete measured flat for RCCdrops/Chajjas Completed all as specified and directed by Engineer-in-charge. |
| 26 | M & L Pre-cast cement concrete block masonary with solid blocks Type C1 1:3:6, exc. 10 cm in width and setting in Cement mortar (1:6) mortar, Completed all as specified and directed by Engineer-in-charge. |
| 27 | S& Ffactory made WPC solid door frames of size 65x100mm including fixing to walls using three numbers dash through bolt on each side Completed all as specified and directed by Engineer-in-charge. |
| 28 | S& Ffactory made single extruded WPC solid door shutters decorative type flush door of size 35mm Completed all as specified and directed by Engineer-in-charge. |
| 29 | S&F extruded aluminum alloy handles (150mm ) fabricated type anodised Completed all as specified and directed by Engineer-in-charge.Make :- Shalimar / jyoti/ Classic/ Ashoka |
| 30 | S&F hinges (150 mm)stainless steel medium weight Completed all as specified and directed by Engineer-in-charge. |
| 31 | S&F aluminum anodised barrel tower bolts (150 mm ) of extruded section Completed all as specified and directed by Engineer-in-charge. |
| 32 | S&F 300 mmAluminium alloy , anodised , sliding door bolt with hasp, staple (bolt type ) and fixing clips of sheet , cast , exctruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed Completed all as specified and directed by Engineer-in-charge. |
| 33 | M&L for Ready mix plaster 10mm thickonfaces of bricks or concrete surface includingincluding preparation of wall surfaces etc Completed all as specified and directed by Engineer-in-charge. |
| 34 | M&L for rendering 5mm thick in ready mix plaster on ceiling surface and finishing the surfaces even and smooth without using extra cement including scrapping down and preparation of ceiling surfaces to receive plaster, scaffolding as reqd etc, Completed all as specified and directed by Engineer-in-charge. |
| 35 | M&L for Ready mix polimer modified cement based plaster 15mm thick on new bricks or concrete surface including preparation of wall surfaces etc Completed all as specified and directed by Engineer-in-charge. |
| 36 | Material & Labour for applying two Coats Of Oil Bound Distemper Over One Coat Of Primer on Internal Wall Completed all as specified and directed by Engineer-in-charge. |
| 37 | Material & Labour for applyingtwo Coats Of Oil Bound Distemper Over One Coat Of Primer on ceiling Completed all as specified and directed by Engineer-in-charge. |
| 38 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additivesM @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. Completed all as specified and directed by Engineer-in-charge. |
| 39 | M & L Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface Completed all as specified and directed by Engineer-in-charge. |
| 40 | M & L 75mm Thick Cement concrete ( 1:4:8 )type D-2 (40mm graded aggregate) Completed all as specified and directed by Engineer-in-charge. |
| 41 | Screed bed or bedding layer of mortar CM(1:6) 15 mm thick for laying floor finishes Completed all as specified and directed by Engineer-in-charge. |
| 42 | M&L non-skidcoloured joint free ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 Sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurryover and including provision of bedding layer 15 mm thick in CM 1 : 4 Completed all as specified and directed by Engineer-in-charge. |
| 43 | M & L for Coloured Glazed ceramic tiles in vertical surface 350 x 250 mmx 7 mm / 450 x350x 7 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match. Completed all as specified and directed by Engineer-in-charge. |
| 44 | M & L for machine cut kota stone slab flooring, 20mm thick over cement screed bas laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror finish polishing all as specified and directed complete |
| 45 | All as per items No44 above but asin skirting Completed all as specified and directed by Engineer-in-charge. |
| 46 | M & L 75mm thick Plinth Protection PCC (1:3:6) using 20mm graded aggregate (0.75 m wide). Completed all as specified and directed by Engineer-in-charge. |
| 47 | M & l for 3mm APP based polymeric membrane minimum weighing 3.5 kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid on primed surface by torched application complete and finally finished as per manufacturers instructions Completed all as specified and directed by Engineer-in-charge. |
| 48 | Screed bed or bedding layer of mortar CM(1:3) 10 mm thickCompleted all as specified and directed by Engineer-in-charge. |
| 49 | Supply only Water Proofing compound |
| 50 | S&F extruded Powder coated aluminiumsection as in window, ventilation,door (powder coated 50 micron in blackcolour) with movable, openable or fixed type shutter or any pattern as directed, aluminumsection medium weight of series B or size as directed by the Engr in charge cut to size , jointed toghter including rubber beading and all necessary fitting Completed all as specified and directed by Engineer-in-charge.(Make: Jindal/Hindalco) Note:- (i) Only aluminum sections measured and paid in this item. (ii) Rate quoted by the contractor shall deemed to be inclusive of all neecssary fittings and fixture such as roller,handle,locks etc (iii) Glass pane and XPM jali measured and paid under supply only rate. |
| 51 | S&Faluminum anodised grill DG- 202 ( 10 mm x 5.2mm ) of Deco grill or equivalent fixed with \"F\" section size not less than 20.60 x 15.20 x 1.5mm thick of approved make.Completed all as specified and directed by Engineer-in-charge.Note:- (i)Make shall be of M/s Decogrille of M/s Associated Groups or equivalent as approved by the GE.(ii) Minimum thickness of anodizing shall be 15 microns. |
| 52 | Supply only 4mm thick sheet figured glass, pin head type and glazing with oil putty in square not exceeding 0.5 Sqm in each pane etccomplete all as specified and directed Completed all as specified and directed by Engineer-in-charge. |
| 53 | Supply only stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of aperture 1.40 mm , fixed in aluminium windows Completed all as specified and directed by Engineer-in-charge. |
| 54 | S&F inGodrej night latch 4 lever for entrance door with fittings Completed all as specified and directed by Engineer-in-charge. |
| 55 | S&F pvc cabinet mirror in repairs of size 600X450 mm Completed all as specified and directed by Engineer-in-charge. Make: poly tuf or Prayag polymers pvt ltd. |
| 56 | M&L Mirror 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plughs with chromium plated brass screws and cup washers in repairs Completed all as specified and directed by Engineer-in-charge.Make-Modiquard/Atul |
| 57 | M&L tubes medium grade galvanised, with all fittings and fixed complete to walls or ceiling or laid in floors 15mm bore dia. Completed all as specified and directed by Engineer-in-charge. |
| 58 | All as per item no.109 above but 20mm bore dia Completed all as specified and directed by Engineer-in-charge. |
| 59 | S&F EWC wall hung WC With in built jet pp soft close silm seat hinges hind ware wall hanging type with plastic sheet cover all as specified and directed of size (H x W x P) 365 x 525 x 400 mm with ‘P’ trap distance 22.5 cm Completed all as specified and directed by Engineer-in-charge. Make: Cera Cat No 92051 (ESSENCE) , Jaquar ;- SLS-WHT-6951 JPPSMor equivalent. |
| 60 | M&L PVC valveless, syphonic action type, 10 ltrs cap flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and flush pipe 32mm dia and fixed in repairs Completed all as specified and directed by Engineer-in-charge. |
| 61 | Supply only PVC connector 15mm size with PTMT nuts of length 450mm |
| 62 | S&Fin repairs for providing and fixing stainless steel (Grade 304)stainless steel hinges, handles, Stainless steel baskets, stainless steel rollers, Stainless steel hinge Italian patter suitable for cabinet and shelves opening / closing operation , Stainless steel perforated cutlery basket of suitable for cabinet,drawers and shelves opening / closing operation. Stainless steel steel Cup and Saucer basket suitable size of cabinet,drawers and shelves opening / closing operation. Stainless steel designer basket suitable size of cabinet,drawers and shelves opening / closing operation.Stainless steel designer basket suitable size of cabinet,drawers and shelves opening / closing operation Stainless steel designer basket suitable size of cabinet,drawers and shelves opening / closing operation stainless steel roller of size25mm x 12mm,505mm lenth suitable for baskets stainless steel vent perforated 1mm thick of size 150mm x 100mm Make-Syntex Plasto board and equivalent approved by Engr in charge. including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts hing roller ext. and bolts complete,stainless steel bolts etc., of required size. Completed all as specified and directed by Engineer-in-charge. |
| 63 | M&L Wash basin, Vitreous China white (Flat back) 630 x 450mmincluding fixinggranite top with ceramic under counter basinpinning in ends of brackets or erecting stand including fixing of waste pipe andetc ( Suppy of pillar tap and waste pipe shall be measured separately) complete all as specified and directed. |
| 64 | S &F15 mm Pillar taps, castcopper alloy, withcapstan heads,chromium plated, screwed down highpressure, with orwithout lettered\"Hot\" or \"Cold\" withlong screwedshanks and fly-nuts, screwed for ironpipe and fixed. Completed all as specified and directed by Engineer-in-charge. |
| 65 | S & F15.00 mm Angle stop valve ofPTMTanycolourhigh pressure screwedfor iron pipe andfixed, (Minimum weight15mm-90gms) Completed all as specified and directed by Engineer-in-charge. |
| 66 | S &F 32 mm bore low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 PVC bends including all necessaryfixed complete to walls, ceilings or in floors etc. Completed all as specified and directed by Engineer-in-charge. |
| 67 | S&F Bib taps, castcopper alloy withcrutch orbutterflyhandle, screweddown, screwed foriron pipe or forbrass ferrule andfixedCompleted all as specified and directed by Engineer-in-charge. |
| 68 | S&F in repair 25 mm fancy type decorative stainless steel double curtain road with doublebracket suitable hanging multiple sets curtains togetherfor window and doorincluding 02 nosedoublebracket and04 nosefancytype rod for each window make- Vist,Marvel,mac decor ,declor equivalent Completed all as specified and directed by Engineer-in-charge. |
| 69 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position Completed all as specified and directed by Engineer-in-charge. |
| 70 | S&F in repairs brass chromium plated towel rail 20mm dia, \"D\" type, 600mm long between flanges. Completed all as specified and directed by Engineer-in-charge. |
| 71 | S&F stainless steel soap dishes approximate size 160mm x 160mm x90mm as Completed all as specified and directed by Engineer-in-charge. |
| 72 | S&F Glass Assembly sheet glass consisting of 5.5mm thick sheet glass 12cm wide with chromium plated bracked guard and railing 60cm long in repairs complete all as specified and directed.. |
| 73 | S&F Brass chromium plated shower rose 125mm size including fixing to steel pipe or union in repairsCompleted all as specified and directed by Engineer-in-charge. |
| 74 | S&F20 mm Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed Completed all as specified and directed by Engineer-in-charge. |
| 75 | S&F 25 mm Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed Completed all as specified and directed by Engineer-in-charge. |
| 76 | M&L for 110 mm dia PVC (SWR)pipe singlesocketed (ISI marked) fixed fixed to wallwith mild steel clampsCompleted all as specified and directed by Engineer-in-charge. |
| 77 | M&L PVC (SWR) 110mmbends any radiusequal Completed all as specified and directed by Engineer-in-charge. |
| 78 | S & F 110 mm bore PVC (SWR) Branch piece, single (single Y) equal or unequal of any radius with access door. Completed all as specified and directed by Engineer-in-charge. |
| 79 | S&F75mm bore PVC soil waste pipepipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps8mm dia with two nuts wall nails etc including taking down of any type Completed all as specified and directed by Engineer-in-charge. |
| 80 | S & F75 mm bore PVC (SWR) Branch piece, single (single Y) equal or unequal of any radius with access door. Completed all as specified and directed by Engineer-in-charge. |
| 81 | M&L 75 mm,PVC (SWR) floor trap, plain with grating including jointing with solvent cement Completed all as specified and directed by Engineer-in-charge. |
| 82 | M&L Rotational moulded polyethylene water storage tanks (Cylindrical verticval with closed top) hoisted & fixed in position in repairs all as specified of 500 ltrs capacity Completed all as specified and directed by Engineer-in-charge. |
| 83 | S/Fin repair 15mm size PVC connection with PTMT nuts 450mm length.Completed all as specified and directed by Engineer-in-charge. |
| 84 | S&F stainless steel grating in ground shape 100mm dia complete all as specified and directed. |
| 85 | Surface exvcavation n exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil Completed all as specified and directed by Engineer-in-charge. |
| 86 | Hardcore of broken stoneguageexc 63mmbut n.exc 100mm deposited spreqad and levelled in layers n exc 15cm thick, watered and rolled/rammed to a true surface using broken stone or boulders Completed all as specified and directed by Engineer-in-charge. |
| 87 | Removing excavated material n exc 50m and depositing where directed at a level n exc 1.50 m above the starting point. |
| 88 | M&L 100 mm thick Cement concrete type D2 1:4:8 (40mm graded aggregates)as in sub baseetc finished surface even and roughwithout using extra cement, Completed all as specified and directed by Engineer-in-charge. |
| 89 | M&L for sand filling under floor or in foundations including watering and cosolidation. Completed all as specified and directed by Engineer-in-charge. |
| 90 | S&F 60 mm machine pressed precast concrete interlocking paver blocks with white cement and color pigment, any shape and size conforming to IS 15658:2006 Completed all as specified and directed by Engineer-in-charge. |
| 91 | M&L PCC 1:2:4 type B2 using 40mm graded crushed stone aggregates as inmass concrete in foundation concrete, sidesand making fair round/ chamfering the edge all as specified and directed by Engineer-in-Charge |
| 92 | Excavation in trenches n.exc 1.50m wide and n.exc 1.50m in depth for fdn etc n.exc 10 sqm on plan and getting out in any type of soil Completed all as specified and directed by Engineer-in-charge.. |
| 93 | Excavating over areas, n exc 1.5 m deep and getting out in soft / disintegrated rock and getting out as specified and directed by Engineer-in-charge. |
| 94 | Excavating over areas,exc 1.5 m deep but not exceeding 3.00mand getting out in soft / disintegrated rock and getting out as specified and directed by Engineer-in-charge. |
| 95 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm in any type of soil Completed all as specified and directed by Engineer-in-charge. |
| 96 | M&L for cement concrete 1:4:8 type D-2 as in concrete bed to drain pipes including packing under, and haunching against the sides of pipes of 150mm dia pipes after they are laid and tested Completed all as specified and directed by Engineer-in-charge. |
| 97 | M&L for 150mm dia Salt glazed stoneware drain pipes laid in trenched and jointed as specified and directed by Engineer-in-charge. |
| 98 | M&L Brick work with sub class \"B\" bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:4. Completed all as specified and directed by Engineer-in-charge. |
| 99 | M&L Rendering 15mm thick on fair faces of brick work or concrete work, finished even and smooth without using extra cement. Completed all as specified and directed by Engineer-in-charge. |
| 100 | M&Lreinfornced cement concrete with design Mix M-30 (using 20mm graded stone aggregate) inslab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like Completed all as specified and directed by Engineer-in-charge. |
| 101 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) flat Completed all as specified and directed by Engineer-in-charge. |
| 102 | S&F TMT bars, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hoopinbg for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips all as specified and directed by Engineer-in-charge. |
| 103 | M&L for Providing precast cement concrete 1:2:4, type B1(20 mm graded aggregate) set in CM 1:6, as in cover slabs (for manholes etc) with plain fair faces, including necessary form work as specified and directed by Engineer-in-charge. |
| 104 | Material and Labour for point wiring using approved colour coding as per IS ,with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade ISI-694 marked drawn through PVC/ Steel concealed conduitwith and includingconcealed GI metal boxes 1.2 mm thick,(18 Guage)50mm deep, with earth dolly, covered with modular white cover plate & frame of suitable module for mounting modular switches, sockets, regulators etcand also including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed for the following:- (a) One light point/ exhaust fan pointcontrolled by one, one way switch 6 Amps Complete all as specified andas directed by Engineer-in-charge. |
| 105 | (b) All as per item No 104 but One5 pin socket outlet plug point, 6 Amps, controlledby one, switchon same boardComplete all as specified andas directed by Engineer-in-charge. |
| 106 | (c) All as per item No 104 but One5 pin socket outlet plug point, 6 Amps, controlledby one, switchon independentboardComplete all as specified andas directed by Engineer-in-charge. |
| 107 | (d) All as per item No 104 but One two way light point controlled by two nos. two way 6A switches Complete all as specified andas directed by Engineer-in-charge. |
| 108 | (e) All as per item No 104 but One ceiling fan point & regulator controlled by one, one way switch 6 Amps Complete all as specified andas directed by Engineer-in-charge. |
| 109 | Description all as per Item No- 104 here-in before but using 2.5 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for one 6 pin socket outlet plug point, 6 Amps independentincluding necessary running of 2.5 Sqmm PVC insulatedmultistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly complete all as specified andas directed by Engineer-in-charge. |
| 110 | Description all as per Item No-104 here-in before but using 4.0 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for 6/16 Amps power point including necessary running of 4.0 Sqmm PVC insulatedmultistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly as specified andas directed by Engineer-in-charge.Note for Item Ser No 104 to 110: (i) Cutting chases for conduits and sinking\"s for GI metalswitch boxes and making good to walls in cement mortar 1:3 to match with existing surfaces shall be carried out by the contractor without any extra cost from the department. |
| 111 | Supply and fixingModular switch, one way6 A, one module, 230 Voltscomplete all as specified andas directed by Engineer-in-charge. |
| 112 | Supply and fixingModular switch, Two way 6 A, onemodule,230 Voltscomplete all as specified andas directed by Engineer-in-charge. |
| 113 | Supply and fixingModular switch, one way 16 A, onemodule, 230 Voltscomplete all as specified andas directed by Engineer-in-charge. |
| 114 | Supply and fixing Modular socket outlet multipurpose, 6A - 2/3 pin combined 2 module, 230 Voltscomplete all as specified andas directed by Engineer-in-charge. |
| 115 | Supply and fixing Modular socket outlet multipurpose,6A/16A - 2/3 pin combined 2 module, 230 VoltsComplete all as specified andas directed by Engineer-in-charge. |
| 116 | Supply and fixing Modular socket outlet multipurpose,6A/16A - 2/3 pin combined with 16 Amps MCB 4 module, 230 Voltscomplete all as specified andas directed by Engineer-in-charge. |
| 117 | Supply and fixing LED flood light 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. Complete all as specified andas directed by Engineer-in-charge. |
| 118 | Supply and fixing USB Charger - 3000mA/15 Watts - Type A + C -1 Module Complete all as specified andas directed by Engineer-in-charge.Make- Legrand Cat No- 5716 88 or Equivalent in Havells, |
| 119 | Supply and fixing Energy efficient, Twinglow 25-Watt+25-Watt Led Up-Down Batten(Warm White + Cool White), polycarbonate material,4\" Tubelight fitting, 2500 Lumen complete with standard warranty of manufacturer from date of purchase/ installationComplete all as specified andas directed by Engineer-in-charge.Make-Philips (Product SKU : 919515813875) or equivalent in Jaquar, crompton |
| 120 | Supply and fixing wall/ surface mounted, LED- 35W ± 10% watt Power consumption, AL. Extruded Housing, 230 VAC, 50Hz batten fitting complete with standard warranty of manufacturer from date of purchase/ installationComplete all as specified andas directed by Engineer-in-charge.Make Jaquar Cat No- HBT-WHT-LKBU4KVS35XC or equivalent in Philips,crompton |
| 121 | Supply and fixing wall/ surface mounted, LED-10 W watt Power consumption, AL. Extruded Housing, Input Voltage 140 V AC - 270 V AC,50Hz, IP 20, batten fitting complete with standard warranty of manufacturer from date of purchase/ installationComplete all as specified andas directed by Engineer-in-charge.Make-Havells Cat No- LHEXACP7IN1W010 or Equivalent in Philips, Jaquar. Cat No- BTI-WHT-LGLZ01X010XW |
| 122 | Supply and fixing energy saving, Full Glow LED Surface Light luminaire complete with Motion Sensor, Power consumption 15 Watt, Round Shape, single Phase 230 Volt. fitting and standard warranty of manufacturer from date of purchase/ installationComplete all as specified andas directed by Engineer-in-charge.Make Philiphs ( Product SKU : 929003671501) or equivalent in Jaquar, Crompton. |
| 123 | Supply and fix for energy saving new generation environmentalfriendly long life versatile pressure die aluminium IP-66 for security light fitting luminaire of capacity 30 watt with high power LEDs as light source and electronic driver , necessary mounting arrangements and provision of 1.0 Sqmm 3 core copper conductor cable multistranded fromceiling rose to light fitting including1.5 metres long GI pipe medium grade bracket of suitable size & shape to light fitting mounting dia, secured and fixed with clamps made out of MS flat iron ofsize 25mm x 5mm, nuts, bolts etc , as approved, Complete all as specified andas directed by Engineer-in-charge.Make- Jaquar Cat No LPCRSRT30WXW or equivalent in Philips, Havells |
| 124 | Supply and fixing,fresh air (exhaust) fan plastic body of200mm sweep, AC single phase, 240V, 50 Hz, Input Voltage, 140-285, , withlouvers and including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to PVC connector block of fan and taking down old exhaust fan carrying to deposit in AGE E/Mstore yard Hamla Complete all as specified andas directed by Engineer-in-charge. |
| 125 | Supply and fixingEnergy Efficientwall mountedfan , Power-32 W consumption on high speed,Input voltage 90-245 V-AC single phase, Speed: 1350 RPM ,50 Hz , 400 mm sweep, 3 blade,and making connections Complete all as specified andas directed by Engineer-in-charge. Make- Atomberg (EFFICIO +) |
| 126 | Supply and fixing ceiling fansworking on single phaseinput voltage 140-285 , Sweep- 1200 mm, Power 32 W,345 RPM ,with232 Air delivery CMM (m3 /min), complete with compact BLDC Motor,blades, down rods, electronic regulator and accessories, including making connections with provision of flexible wire 23 /0.0076 twin core copper conductor from ceiling rose/connector to fan Complete all as specified andas directed by Engineer-in-charge. Make- Atomberg (Renesa Alpha) or Equivalent in Havells Model -Trinity |
| 127 | Supply and fix electric water heater, storage type shock proofwith Glass line inner tank (rust proof) and heating element upto 2 KW capacity 15 litre,temperature display, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV,shock safe safety plug connected with 3 core cable of suitable size / length, including 04 Nos of hold fastener nuts of required suitable size fixed in brick / stone wall complete all as specified and as directed. Make Havells Cat No- GHWAMJSWH015Note- Minimum 02 Years warranty on Inner tank and 01 Years on heating element shall be provided by manufacturer from date of purchase. Firm should obtain warranty/ gurantee from the manufacturer & submit the same to the department. |
| 128 | M & L for PVC connection pipe (copper) chromium plated 8 mm dia both end threaded incl brass coupling bolt cone washer complete , length of pipe is not less than 450 mm suitable for Hot/ cold water system Complete all as specified andas directed by Engineer-in-charge. |
| 129 | Supply and fixing amp rating 240V, 10KA \"C\" curve, IP 20 protected terminals, miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.(a) SP 5 To 32 AMP |
| 130 | (b) All as per item No 129 but SPN 32 AMP |
| 131 | Supply and fixing 415V 10KA \"C\" curve, IP 20 protected terminals,miniature circuit breaker (MCB) TPN 40and current carrying capacity in the DB complete with connection testing and commissioning. |
| 132 | S & F sheet metal enclosure suitable for Flush / Surface Mounting, MCB DBTPN 4 Way with 100 Amps rated bus bar for each phase, Fully insulated & shrouded Neutral bars, Earthbar and Cable ties for Cable management, &provision for FP MCB / Isolator / RCCB / RCBO as incomer and SP MCB\"s as outgoing ,415Volts, IP 43 - #IK 09 with metal double door & magnetic locking system includinginserting the DBs in wall by cutting the brick/ stone masonary etc and making good of disturbed surface in cement mortar to match the existing surface &colour to wall Complete all as specified andas directed by Engineer-in-charge. (Make Legrand Cat No -5076 80 or equivalent.) |
| 133 | M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 4 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty conduit and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 4 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed. Note- Three run of 4 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directedComplete all as specified andas directed by Engineer-in-charge. |
| 134 | M&L Cross-arms, Bracings, Supports, Clamps and Back Plates fabricated from Structural Steel Sections including Nuts, Bolts, Washer, welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated/ directed and inclusive of one coat of Aluminium Primerone Under Coat and One Finishing Coat of Aluminium Paint, complete all as specified and as directed. |
| 135 | M&L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried vertically directly in ground (Earth pit not less than 2.25mtr deep below normal ground level andtop edge of the plate not less than 1.5 mtr below ground level),connected to and including galvanized steel eathing lead wire 4 mm dia by means of bolts nuts check nuts and washers etcGI pipe 15mm dia medium grade for protection of GI strip both to be provided to the extent of 7.5 meters, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/ plinths or fixed on walls oe concealed in walls etc with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate , including PCC (1:2:4) type B-1 earth pit with MS angle iron frame , cast iron cover with locking arrangement, with GI pipe 20mm dia medium grade pipe and MS funnel with wire mesh for watering arrangement including necessary excavation and earth work in any type of strata and testing on completion. Complete all as specified andas directed by Engineer-in-charge.Note:- GI wire 4.0 mm dia and GI pipe 20 mm bore medium grade for encasing GI wire 4.0 mm dia beyond 7.50 M length per earthing if so required at site shall be measured and paid for seperately under relevant items. |
| 136 | Excavation in Trenches not exc 1.50 Metre wide and not exc 1.50 Metre depth for laying of UG Cable etc and getting out in Soft/Loose Soil, Complete all as specified andas directed by Engineer-in-charge. |
| 137 | Excavation in Trenches not exc 1.50 Metre wide and not exc 1.50 Metre depth for laying of UG Cable etc and getting out in Hard Dense Soil, Complete all as specified andas directed by Engineer-in-charge. |
| 138 | Material and labour forcable route marker made of Pre-cast cement concrete block masonry Type C1 1:3:6 (20mm graded aggregrate)with solid blocks, exc. 10 cm in width and settingin cement concrete mortar 1:6, includingembosing DANGER/ LT CABLE / MESon cable route marker and properly painting with approved colour,size of cable route marker 900x300x100mm completeburied in ground for a depth of 45 cm & necessary earth work Complete all as specified andas directed by Engineer-in-charge. |
| 139 | Supply and layingHDPE Pipe PN 10 Size 50mm laid in trenches along with accessories such as couplerfor electrical applications as in cable protection pipe from physical damageComplete all as specified andas directed by Engineer-in-charge. |
| 140 | Supply and laying across road crossing reinforced concrete pipes, class NP2, laid and jointed complete with collars of size 150 mm Complete all as specified andas directed by Engineer-in-charge. |
| 141 | Material and Labour Soling (or sub base) 150 mm spread thickness with broken boulders or quarried stone, inter stices filled, surface formed and rolled and consolidated to required gradient and camber complete all as specified and directed. |
| 142 | M&L Cement Concrete Type B2-1:2:4 (40mm graded aggregate) as in Foundation filling and mass concretefor grounting of panel and making good disturbed road surfaces including necessary Formwork (as/if required) Complete all as specified andas directed by Engineer-in-charge. |
| 143 | Supply & laying LTAluminium Conductor Power Cables, Stranded Conductor, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Armoured galvanised steel strip,Extruded PVC Type ST2 Outer Sheathed, 1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments. cross-sectional area 16 Sqmm 4 Core, passing in HDPE Pipe laid in trenches/ fixing on surface of Wall in cable tray securing with GI Cable clampsincluding Brass Cable Glands at termination end points Mild Steel Flat Iron Clamps of adequate size, etc. and Testing Complete all as specified andas directed by Engineer-in-charge. |
| 144 | Supply and fixing DPX³ 160 MCCB with O/L & S/Cthermal magnetic protection unit, 25 KA breaking Capacity, 4 Pole , 63 Amps, of Make Legrand Cat No 4200 53 or Equivalent in L&T |
| 145 | Material and labour forPipe route marker made of Pre-cast cement concrete block masonry Type C1 1:3:6 (20mm graded aggregrate)with solid blocks, exc. 10 cm in width and settingin cement concrete mortar 1:6, includingembosing WATER PIPE / MESon Pipe route marker and properly painting with approved colour,size of cable route marker 900x300x100mm completeburied in ground for a depth of 45 cm & necessary earth work Complete all as specified andas directed by Engineer-in-charge. |
| 146 | Supply and fixing Unplasticised PVC (UPVC) pipes of pressure rating 10 kgf / cm2 with all fitting and fixed complete to walls with clips, wall hooks, wooden plugs, and ceilings or laid in floors complete all as specified and as directed bore of pipe .(a) Bore of pipe 25 mm |
| 147 | Supply and fixing Unplasticised PVC (UPVC) pipes of pressure rating 10 kgf / cm2 with all fittings and fixed complete, together with Pipe,laid in trenchescomplete all as specified and as directed bore of pipe .(a) Bore of pipe 32 mm |
| 148 | (b) All as per item No 157 but Bore of pipe 40 mm |
| 149 | (c) All as per item No 157 but Bore of pipe 50 mm |
| 150 | (d) All as per item No 157 but Bore of pipe 65 mm |
| 151 | (e) All as per item No 157 but Bore of pipe 75 mm |
| 152 | S & F UPVC Ball valve 25mm Outer dia heavy weightas per pre requirement of the site with handle screwed both ends for UPVC Pipes or for unions Complete all as specified andas directed by Engineer-in-charge. |
| 153 | S & F UPVC Ball valve 65mm Outer dia heavy weightas per pre requirement of the site with handle screwed both ends for UPVC Pipes or for unions Complete all as specified andas directed by Engineer-in-charge. |
| 154 | S & F UPVC Ball valve 75mm Outer dia heavy weightas per pre requirement of the site with handle screwed both ends for UPVC Pipes or for unions Complete all as specified andas directed by Engineer-in-charge. |
| 155 | M & L for construction bricks masonery for valves pitsize 60X60X60 CM (internal dimesion)constructed complete with MS angle iron frame work (angle size 40X40X 6mm )MS sheet 3 mm thick top cover openable through hingesand locking arrangement rendering in CM 1:4 and paintaing steel surface with two coats of bituminous paint inside and on exposed surfaces Complete all as specified andas directed by Engineer-in-charge. |
| 156 | Deduct Credit for Demolished/ Dismantled material Rs. (-) 0.00 (Minus) as listed in Schedule of Credit.Note 1:- Tenderers will not quote against this item being a tentative amount to be considered to arrive at the \"Contract Sum\"Note 2:- The tenderer must keep in mind when quoting rates against items out in multiple store house having height 4 mts to 7 mts. Necessary scaffolding and saftey measures required during execution of work are including in this items. Note 3:-If the contractor quotes different rates for similar/ same items, the lowest quoted rate will be considered for the said item. |