| 1 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 2 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone shingle 20 mm nominal size) excluding the cost of centring and shuttering in : |
| 3 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in :a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 4 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 5 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 6 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size). |
| 7 | Reinforcement of RCC work including bending, binding and placing in position complete. |
| 8 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete. |
| 9 | Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand). |
| 10 | Half brickmasonry wall with best available local bricks in cement mortar 1:4 |
| 11 | Extra for brick work with best available local brick in superstructure above plinth level |
| 12 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 13 | Centring and shuttering including strutting, propping etc and removal of form work for: |
| 14 | a) Foundation, footings, bases of columns etc. and mass concrete. |
| 15 | b) Column, pillars, posts and struts etc. |
| 16 | C) Lintels, beams, girders, bressumers and cantilevers etc. |
| 17 | d Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). |
| 18 | 75 mm thick cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) finished with a floating coat of neat cement. |
| 19 | Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position. |
| 20 | Providing best available local wood (Class - B II) work in frames of false ceiling, partitions and trusses etc, sawn and put up in position. |
| 21 | Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including necessary iron butt hinges with necessary screws. a) 38 mm thick best available local wood, class - B I |
| 22 | 12 mm cement plaster 1 : 3 (1 cement :3 fine sand). |
| 23 | Providing and fixing MS round or square bars at required spacing in wooden frames of windows and clerestory windows. |
| 24 | Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc. |
| 25 | Providing GI .sheet roofing fixed with galvanised iron J or L hooks, bolts & nuts 8 mm dia with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete, excluding the cost of purlins, rafters and trusses. |
| 26 | Providing and fixing 2.50 cm thick approved local wood eaves boards 23 cm wide with necessary mouldings etc. |
| 27 | Providing & fixing 4.0 mm thick asbestor plain sheet ceiling pa approved quality with necessary nail etc complete |
| 28 | 25mm thick wooden shelves supported on 40 x 4 0 x 6 mm \"T\" or \"L\" iron brackets fixed at suitable distance but not exceding 75 cm apart in 7.5 x 7.5 x 15 cm block of cement concrete mix 1 : 3 : 6 ( 1cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) with :a) Approved local wood best available class - B. |
| 29 | Providing and fixing Aluminum sliding door bolts, bright finished or and black enamelled with nuts and screws etc complete.a) 250 x 16 mm. |
| 30 | Providing and fixing Aluminum tower bolts (barrel type) with necessary screws etc complete. |
| 31 | a) 250 x 10 mm |
| 32 | b) 200 x 10 mm |
| 33 | c) 150 x 10 mm |
| 34 | Providing and fixing Aluminum handles with necessary screws etc complete |
| 35 | a) 125mm |
| 36 | b) 100 mm |
| 37 | Applying priming coat with ready mixed primer of approved brand and manufacture on wood work. |
| 38 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade. |
| 39 | Finishing walls with water proofing cement paint of approved brand and manufacture and of required shade on New work (three or more coats) to give an even shade. |
| 40 | Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10mmdia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size). |
| 41 | Making plinth protection 50 mm thick of Cement Concrete 1:3:6 ( 1 Cement, 3 Sand, 6 Stone Aggregate using 20 mm nominal size) over 75 mm bed of stone balast 40 mm nominal size well rammed & consolidated and grouted with fine sand including finishing the top smooth |
| 42 | Construction of cement concrete drain 15 cm wide and 15 cm deep in cement concrete 1:3:6 ( 1 Cement, 3 Sand, 6 hard graded stone chips/shingle of 40 mm down grade) 8 cm thick on side & bottom & plastering on all exposed surfaces with 12 mm thick cement mortar 1:3 ( 1 Cement, 3 Coarse Sand) including shuttering complete |
| 43 | Wiring for light Point/fan point /exhaust fan point/call bell point with 1.5sqmm FR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate suitable GI works and earthingthe point with 1.5sqmm FR PVC insulated copper Conductor single core cable etc. as required. |
| 44 | a) Group-A |
| 45 | Wiring for light/Power Plug with 2x4 sqmm FR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit along with 2 No. 4sqmm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 46 | Wiring for Circuit/Submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 47 | a) 2x4sqmm + 1x4 sqmm earth wire |
| 48 | b) 2x2.5sqmm + 1x2.5sqmm Earth Wire. |
| 49 | Supplying and fixing of following sizes of medium class PVC conduit alongwith accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 50 | a) 20mm |
| 51 | b) 25 mm |
| 52 | Supplying and fixing following modularswitch/socket on the existing modular pleate and switch box including connections but excluding modular plate etc. as required. |
| 53 | a) 15/16 amp switch & Socekt combined. |
| 54 | b) 3 Pin 5/6 amp socket outlet |
| 55 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc./ as required. |
| 56 | Supplying and fixing of AC Ceiling fan 1200 mm Sweep |
| 57 | Supplying and fixing of 4ft. Tube fitting with flourscent tube |
| 58 | Supplying and fiixing 3 Pin, 5 amp ceilling rose on the existing junction box/wooden block including connection etc. as required. |
| 59 | Supplyingof Flexible wire |
| 60 | Supplying of PVC Tape |
| 61 | Erection of wall bracket/ceiling fittings of all sizes and shapes containing upto two GLS lamps per fitting, complete with all accessories including connection etc. as required. |
| 62 | Supplying and fixing call bell/buzzer suitable for single phase 230 volts, complete as required. |
| 63 | Installation, testing and commissioning of pre-wired, fluorescent fitting/compact fluorescent fitting of all types, wth all accessories and tube etc/ directly on ceiling/wall, including connection with 1.5sqmm FR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 64 | Insatallation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30cm) with 1.5sq.mm FR PVC insulated, copper conductor, single core cable, including providing and fixing p[henolic laminated sheet cover on the fan box etc. as required. |
| 65 | Supplying & fixing of Energy meter 1 phase & neutral (5-30 A) |
| 66 | Laying of 3 1/2 x 35 sqmm UG Cable in the trences and refilling |
| 67 | Supply of copper earthing plate of size 600x600x4mm |
| 68 | Supply of Cupper Strip of size 25x4mm |