| 1 | BUILDING CIVIL WORKS |
| 2 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, fillets, columns, pillars, posts and struts, etc., above plinth level up to first floor level, excluding the cost of centering, shuttering, finishing and reinforcement. b. M20 or 1:11/2:3 (1 Cement: 11/2 Coarse sand: 3 graded stone aggregate 20mm nominal size. |
| 3 | Reinforced cement concrete work in beams, slabs, roofs having slope up to 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to first floor level, excluding the cost of centering, shuttering, finishing and reinforcement.b. M20 or 1:11/2:3 (1 Cement: 11/2 Coarse sand: 3 graded stone aggregate 20mm nominal size. |
| 4 | Supplying, fitting and fixing in position reinforcement bars upto 1st floor level, conforming to relevant I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurements for the same is required) (c) Thermo-Mechanically Treated bars. |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge.Columns, Pillars, Piers, Abutments, Posts and Struts (using steel) |
| 6 | (a) Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick |
| 7 | (b)Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick. |
| 8 | Brick work in cement mortar with first class brick in super structure above plinth level up to first floor level in all shapes and sizes:(a) cement mortar 1:4 (1 cement : 4coarse sand) |
| 9 | 12 mm cement plaster of mix (a)1:4(1 -cement4 fine sand) |
| 10 | 15mmCement plaster on rough side of single or half brick wall of mix (a) 1:4 (1 -cement : 4 fine sand) |
| 11 | Finishing wall with premium acrylic smooth exterior paint with silicone additives of requiered shade including scaffolding New work two or more coats applied @1.43 ltr/10sqm over and including priming coat of exterior primer applied @ 2.20 kg/10sqm |
| 12 | Distempering with oil bound washable distemper of approved brand and manufacture to give a shade. New work (two or more coats) over and including water thinable priming coat with cement primer. |
| 13 | Providing and laying Ceramic glazed floor tiles of size 300 x 300 mm thickness to be specified by the manufacturer of 1st quality conforming to is 15622 of approved make, laid on 20 mm thickcement mortar 1:4 (1 cement : 4 coarse sand)jointing with grey cement slurry @ 3.3 kg/sqm including poiting the joints with white cement and matching pigments etc complete. |
| 14 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours and shades of any size approved by Enginineer-in- Charge, in walls, skirting, risers of steps and dados over 12 mm thick bed of cement mortar1:3 (1 cement : 3 coarse sand)and jointing with grey cement slurry @ 3.3 kg/sqm, including pointing in white cement mixed with pigment of matching shade complete. (b) premium range |
| 15 | Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including structural steel etc. as required.(b) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 16 | Providing, fitting and fixing steel windows (including ventilators) of standard rolled steel sections as per relevant I.S. Code, joints mitred and welded with 15mmx3mmx100mm lugs embedded in cement concrete block of M-10 grade including providing and fixing of projecting hinges (not more than 65mm and not less than 15mm wide) bolting device, steel handles, pegs, stays of 300mm long etc. complete including providing 12mmx12mm sq. bars duly welded to steel frame at not more than 12cm c/c applying a priming coat of red-lead paint etc. complete as per drawing. (a) Openable |
| 17 | Providing and fixing glass panes with putty and glazing clip in steel window / doors /cleastory windows all complete with(a) 4.00 mm thick glass panes |
| 18 | Providing wood work in frame of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold hold fast lugs or with dash fasteners of required diameter & length. (c) With 1st Class Local wood(ii )Champa/Diengrai |
| 19 | Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part-I) decorative type , core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:(a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 20 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanished steel sections (galvanished @ 120 grams/sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm madefrom 0.30 mm thick (m9nimum) sheet, spaced at 1200 mm centre to centre and cross \"T\" od size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between \"T\" at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27x37x25x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanished butterfly level clips of size 85x30x0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposedwidth of 24 mm of all T-sections shall be pre- painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in charge.12.5 mm thick square edge PVC laminated Gypsum Tile of size 595x595 mm, made Gypsum Plaster board, manufactured from natural gypsum as per IS:2095 I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. |
| 21 | Providing and fixing to existing door frames.(b) 30 mm thick Fibre glass Reinforced Plastic (FRP) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/ Polystyrene foam to be used as filler material througout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table -3 of IS: 14856, complete as per direction of Engineer-in-charge. |
| 22 | Providingand fixing bright finished brass 100mm mortise latch and lock, ISI marked with six levers and a pair of anodised (anodic coating no less than grade AC 10 as per IS 1868) ALUMNIIUMlever handles of approved quality with necessary screws etc complete. |
| 23 | Grading roof for water proofing treatment with(C ) Cement mortar 1: 4(1 cement : 4coarse sand) |
| 24 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade. (a) new work (two or more coats over an undercoat of suitable shade with ordinary paint of approved brand and manufacture) |
| 25 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete:(b) 200xI0 mm |
| 26 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete:(a) 125 mm |
| 27 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion, (i) Single soceted pipes.(b) 110 mm diameter |
| 28 | Extra for carriage including loading and unloading and all charges complete beyond the initial lead of 5 Km |
| 29 | Carriage of Sand Distance = (65-5)=60 Kms (from Kynshi) |
| 30 | (i) For 5-10 km |
| 31 | (ii) For 10-20 km |
| 32 | (iii) For beyond 20 km |
| 33 | Carriage of Stone aggregates = (25-5)=20 Kms (from Laitkor) |
| 34 | (i) For 5-10 km |
| 35 | (ii) For 10-20 km |
| 36 | (iii) For beyond 20 km |
| 37 | Carriage of Steel (Distance = 15-5 =10 Kms (from Shillong) |
| 38 | (i) For 5-10 km |
| 39 | (ii) For 10-20 km |
| 40 | Providing & fixing Dura board HD-100 pre-moulded compessible filler board at all heights and depths of minimun density 95Kg/cum, non-staining having less than 1% water absorption, compression recovery of 93% (minimun) as per manufactured specification with polysulphide sealant to seal the expansion joint including preparation of surface, Polymer Modified Mortar(PMM) (Proportion 1cement: 3sand: 1 acrylic polymer) nosing, carriage of materials, cutting and placing to the required size complete at all levels as per drawings and direction of Engineer - in - Charge.(d) 50mm thick |
| 41 | WATER SUPPLY & SANITARY |
| 42 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:(a) White Vitreous China Wash basin size 630mm x450mm with a pair of 15 mm C.P. brass pillar taps |
| 43 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 44 | Providing and fixing PTMT soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 45 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.(a) 450 mm |
| 46 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand Cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors whereverrequired:(a) White Vitreous china Orissa pattern W .C. pan of size 580x440 mm with integral type foot rests |
| 47 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:(a) W.C. pan with ISI marked white solid plastic seat and lid. |
| 48 | Providing and fixing toilet paper holder: C.P. brass |
| 49 | Providing and fixing mirror Of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing:(d) Rectangular shape 1500x450 mm |
| 50 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.(a) 75 mm diameter |
| 51 | (b) 110 mm diameter |
| 52 | Providing and fixing G.l. pipes complete with G.l. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall(i) 15 mm diameter nominal bore |
| 53 | (ii) 25 mm diameter nominal bore |
| 54 | Providing and fixing brass bib cock of approved quality:(a) 15 mm nominal bore |
| 55 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.(a) 15 mm nominal bore |
| 56 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:(a) 15 mm nominal bore |
| 57 | Providing and fixing white vitreous China flat back all wall corner type lipped front Urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cisterns with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting and fittings and brackets, cutting and making good the walls and floors wherever required:(a) One urinal basin with 5 litre white P.V.C. automatic flushing cirterns |
| 58 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |