| Sl. No. | Item Description |
| 1 | Dismantling stone masonry in lime or cement mortar including stacking the materials as directed with all leads, lifts excetra complete. |
| 2 | Dismantling the reinforced cement concrete work 1:2:4 and sorting out the materials such as steel excetra as directed and stacking them within the specified lead as directed excetra complete. |
| 3 | Removing doors and windows with frames and stacking the materials as directed with all leads, lifts excetra complete. |
| 4 | Removing brick bat coba including stacking the spoils as directed with all leads, lifts excetra complete. |
| 5 | Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts excetra complete. |
| 6 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. - (Lift upto 1.5 metre) By Mechanical Means |
| 7 | Excavation for foundation in hard murum including removing the excavated material upto a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. (Lift upto 1.5 metre) By Mechanical Means |
| 8 | Excavation for foundation in hard murum and boulders including removing the excavated materials upto a distance of 50 metre beyond the building area and stacking and spreading as directed dewatering preparing the bed for the foundation and necessary back filling, ramming, watering including shoring the strutting excetra complete. (Lift upto 1.5 metre) By Mechanical Means |
| 9 | Excavation for foundation in soft rock and old cement and lime masonry foundations including removing the excavated materials upto a distance of 50 metre beyond the building area and stacking as directed including dewatering, preparing the bed for the foundation and necessary back filling, with available earth, murum, ramming, watering including shoring and strutting excetra complete. (Lift upto 1.5 metre) By Mechanical Means |
| 10 | Excavation for foundation in hard rock by chiselling wedging, line drilling excetra including trimming and levelling the bed, removing the excavated materials upto a distance of 50 metres beyond the building area and stacking as directed, dewatering and back filling with available earth / murum, ramming, watering complete. (Lift upto 1.5 metre) By Mechanical Means |
| 11 | Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the bottom surface and sides for excavation at the rate of 5 liters of emulsion concentrates of 1.0 percent of clorophyriphoas per square metre of surface area covering ten years guarantee on bond paper |
| 12 | Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the backfill in immidiate contact with foundation at the rate of 5 litres of emulsion concentrates of 1.0 percent of clorophyriphoas per square metre of vertical surface area covering ten years guarantee on bond paper. |
| 13 | Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyriphoas per square metre of surface area covering ten years guarantee on bond paper. |
| 14 | Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 centimetre to 1.5 centimetre diameter about 30 centimetre to 60 centimetre deep at 15 centimetre center to center as close to the wall as possible and to inject 0.5 percent of aldrin or clorophyrifos at the rate of 7.5 litres per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper. (For Ground Floor) |
| 15 | Providing dry trap/ granite/ quartzite/ gneiss rubble stone soiling 15 centimetre to 20 centimetre thick including hand packing and compacting, excetra complete. |
| 16 | Providing and laying Cast in situ / Ready Mix cement concrete M-15 of trap / granite / quartzite / gneiss metal for steps including steel centering, plywood / steel formwork, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing, excetra complete. The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin, excetra (Wooden centering will not be allowed.) with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). |
| 17 | Providing fly ash brick masonry with conventional / Indian Standard type fly ash bricks in cement mortar 1:6 in foundation and plinth including bailing out water manually, striking joints, racking out joints, watering and scaffolding, excetra complete. (using ARTIFICIAL SAND). |
| 18 | Filling in plinth and floors with approved excavated materials in 15 centimetre to 20 centimetre layers including watering and compacting, excetra complete. |
| 19 | Filling in plinth and floors with contractors material / brought from outside and approved by Engineer In-Charge, in 15 centimetre to 20 centimetre layers including watering and compaction, excetra complete. |
| 20 | Providing and laying in situ cement concrete M-20 with tremix treatment for 100 milimetre thickness for flooring with groove cutting of 4 milimetre wide 20 milimetre deep with necessary refilling with bitumen, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). |
| 21 | Providing and laying chequered tiles of approved quality of size 30 centimetre X 30 centimetre and confirming to indian standard for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). |
| 22 | Providing and laying Cast in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of reinforced cement concrete columns and steel stanchions, excetra including bailling out water, formwork, cover blocks, compaction, curing and roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel), excetra complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. with fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND). |
| 23 | Providing and laying cast in situ / Ready Mix Cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete pardi of required thickness including centering, formwork, cover blocks, compacting, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). |
| 24 | Providing and laying cast in situ / Ready Mix Cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete pardi of required thickness including centering, formwork, cover blocks, compacting, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For First Floor) (using ARTIFICIAL SAND). |
| 25 | Providing and laying cast in situ / Ready Mix Cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete pardi of required thickness including centering, formwork, cover blocks, compacting, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For 2nd Floor) (using ARTIFICIAL SAND). |
| 26 | Providing and laying cast in situ / Ready Mix Cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete pardi of required thickness including centering, formwork, cover blocks, compacting, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For 3rd Floor) (using ARTIFICIAL SAND). |
| 27 | Providing and laying cast in situ / Ready Mix Cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete pardi of required thickness including centering, formwork, cover blocks, compacting, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For 4th Floor) (using ARTIFICIAL SAND). |
| 28 | Providing and laying cast in situ / Ready Mix Cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete pardi of required thickness including centering, formwork, cover blocks, compacting, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For 5th Floor) (using ARTIFICIAL SAND). |
| 29 | Providing and laying cast in situ / Ready Mix Cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete pardi of required thickness including centering, formwork, cover blocks, compacting, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For 6th Floor) (using ARTIFICIAL SAND). |
| 30 | Providing and laying cast in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, compaction, roughening if special finish is to be provided and curing excetra completet (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). |
| 31 | Providing and laying cast in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, compaction, roughening if special finish is to be provided and curing excetra completet (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For First Floor) (using ARTIFICIAL SAND). |
| 32 | Providing and laying cast in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, compaction, roughening if special finish is to be provided and curing excetra completet (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For 2nd Floor) (using ARTIFICIAL SAND). |
| 33 | Providing and laying cast in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, compaction, roughening if special finish is to be provided and curing excetra completet (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For 3rd Floor) (using ARTIFICIAL SAND). |
| 34 | Providing and laying cast in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, compaction, roughening if special finish is to be provided and curing excetra completet (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For 4th Floor) (using ARTIFICIAL SAND). |
| 35 | Providing and laying cast in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, compaction, roughening if special finish is to be provided and curing excetra completet (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For 5th Floor) (using ARTIFICIAL SAND). |
| 36 | Providing and laying cast in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, compaction, roughening if special finish is to be provided and curing excetra completet (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For 6th Floor) (using ARTIFICIAL SAND). |
| 37 | Providing and laying cast in situ /Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). |
| 38 | Providing and laying cast in situ /Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For First Floor) (using ARTIFICIAL SAND). |
| 39 | Providing and laying cast in situ /Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For 2nd Floor) (using ARTIFICIAL SAND). |
| 40 | Providing and laying cast in situ /Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For 3rd Floor) (using ARTIFICIAL SAND). |
| 41 | Providing and laying cast in situ /Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For 4th Floor) (using ARTIFICIAL SAND). |
| 42 | Providing and laying cast in situ /Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For 5th Floor) (using ARTIFICIAL SAND). |
| 43 | Providing and laying cast in situ /Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For 6th Floor) (using ARTIFICIAL SAND). |
| 44 | Providing and laying cast in situ / Ready Mix cement concrete M-25 of Trap / granite /quartzite/ gneissmetal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand /Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). |
| 45 | Providing and laying cast in situ / Ready Mix cement concrete M-25 of Trap / granite /quartzite/ gneissmetal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand /Crushed sand VSI Grade finely washed etc) (For First Floor) (using ARTIFICIAL SAND). |
| 46 | Providing and laying cast in situ / Ready Mix cement concrete M-25 of Trap / granite /quartzite/ gneissmetal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand /Crushed sand VSI Grade finely washed etc) (For 2nd Floor) (using ARTIFICIAL SAND). |
| 47 | Providing and laying cast in situ / Ready Mix cement concrete M-25 of Trap / granite /quartzite/ gneissmetal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand /Crushed sand VSI Grade finely washed etc) (For 3rd Floor) (using ARTIFICIAL SAND). |
| 48 | Providing and laying cast in situ / Ready Mix cement concrete M-25 of Trap / granite /quartzite/ gneissmetal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand /Crushed sand VSI Grade finely washed etc) (For 4th Floor) (using ARTIFICIAL SAND). |
| 49 | Providing and laying cast in situ / Ready Mix cement concrete M-25 of Trap / granite /quartzite/ gneissmetal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand /Crushed sand VSI Grade finely washed etc) (For 5th Floor) (using ARTIFICIAL SAND). |
| 50 | Providing and laying cast in situ / Ready Mix cement concrete M-25 of Trap / granite /quartzite/ gneissmetal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand /Crushed sand VSI Grade finely washed etc) (For 6th Floor) (using ARTIFICIAL SAND). |
| 51 | Providing and laying cast in situ /Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete waist slab and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood / steel formwork, steel props, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). |
| 52 | Providing and laying cast in situ /Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete waist slab and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood / steel formwork, steel props, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For First Floor) (using ARTIFICIAL SAND). |
| 53 | Providing and laying cast in situ /Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete waist slab and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood / steel formwork, steel props, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For 2nd Floor) (using ARTIFICIAL SAND). |
| 54 | Providing and laying cast in situ /Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete waist slab and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood / steel formwork, steel props, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For 3rd Floor) (using ARTIFICIAL SAND). |
| 55 | Providing and laying cast in situ /Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete waist slab and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood / steel formwork, steel props, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For 4th Floor) (using ARTIFICIAL SAND). |
| 56 | Providing and laying cast in situ /Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete waist slab and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood / steel formwork, steel props, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For 5th Floor) (using ARTIFICIAL SAND). |
| 57 | Providing and laying cast in situ /Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete waist slab and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood / steel formwork, steel props, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For 6th Floor) (using ARTIFICIAL SAND). |
| 58 | Providing and laying cast in situ / Ready Mix cement concrete M-25 of trap metal for reinforced cement concrete chajja as per detailed design and drawings including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate natural sand/V.S.I. quality Artificial Sand (For Ground Floor) (using ARTIFICIAL SAND). |
| 59 | Providing and laying cast in situ / Ready Mix cement concrete M-25 of trap metal for reinforced cement concrete chajja as per detailed design and drawings including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate natural sand/V.S.I. quality Artificial Sand (For First Floor) (using ARTIFICIAL SAND). |
| 60 | Providing and laying cast in situ / Ready Mix cement concrete M-25 of trap metal for reinforced cement concrete chajja as per detailed design and drawings including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate natural sand/V.S.I. quality Artificial Sand (For 2nd Floor) (using ARTIFICIAL SAND). |
| 61 | Providing and laying cast in situ / Ready Mix cement concrete M-25 of trap metal for reinforced cement concrete chajja as per detailed design and drawings including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate natural sand/V.S.I. quality Artificial Sand (For 3rd Floor) (using ARTIFICIAL SAND). |
| 62 | Providing and laying cast in situ / Ready Mix cement concrete M-25 of trap metal for reinforced cement concrete chajja as per detailed design and drawings including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate natural sand/V.S.I. quality Artificial Sand (For 4th Floor) (using ARTIFICIAL SAND). |
| 63 | Providing and laying cast in situ / Ready Mix cement concrete M-25 of trap metal for reinforced cement concrete chajja as per detailed design and drawings including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate natural sand/V.S.I. quality Artificial Sand (For 5th Floor) (using ARTIFICIAL SAND). |
| 64 | Providing and laying cast in situ / Ready Mix cement concrete M-25 of trap metal for reinforced cement concrete chajja as per detailed design and drawings including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate natural sand/V.S.I. quality Artificial Sand (For 6th Floor) (using ARTIFICIAL SAND). |
| 65 | Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For Ground Floor) |
| 66 | Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For First Floor) |
| 67 | Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For 2nd Floor) |
| 68 | Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For 3rd Floor) |
| 69 | Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For 4th Floor) |
| 70 | Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For 5th Floor) |
| 71 | Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For 6th Floor) |
| 72 | Providing fly ash brick masonry with conventional / Indian Standard type fly ash bricks in cement mortar 1:6 in superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). |
| 73 | Providing fly ash brick masonry with conventional / Indian Standard type fly ash bricks in cement mortar 1:6 in superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For First Floor) (using ARTIFICIAL SAND). |
| 74 | Providing fly ash brick masonry with conventional / Indian Standard type fly ash bricks in cement mortar 1:6 in superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For 2nd Floor) (using ARTIFICIAL SAND). |
| 75 | Providing fly ash brick masonry with conventional / Indian Standard type fly ash bricks in cement mortar 1:6 in superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For 3rd Floor) (using ARTIFICIAL SAND). |
| 76 | Providing fly ash brick masonry with conventional / Indian Standard type fly ash bricks in cement mortar 1:6 in superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For 4th Floor) (using ARTIFICIAL SAND). |
| 77 | Providing fly ash brick masonry with conventional / Indian Standard type fly ash bricks in cement mortar 1:6 in superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For 5th Floor) (using ARTIFICIAL SAND). |
| 78 | Providing fly ash brick masonry with conventional / Indian Standard type fly ash bricks in cement mortar 1:6 in superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For 6th Floor) (using ARTIFICIAL SAND). |
| 79 | Providing second class fly ash Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 milimetre diameter / 2 hoop iron strips 25 milimetre X 1.6 milimetre at every third course, properly bent and bounded at ends, scaffolding, racking out joints and watering, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). |
| 80 | Providing second class fly ash Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 milimetre diameter / 2 hoop iron strips 25 milimetre X 1.6 milimetre at every third course, properly bent and bounded at ends, scaffolding, racking out joints and watering, excetra complete. (For First Floor) (using ARTIFICIAL SAND). |
| 81 | Providing second class fly ash Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 milimetre diameter / 2 hoop iron strips 25 milimetre X 1.6 milimetre at every third course, properly bent and bounded at ends, scaffolding, racking out joints and watering, excetra complete. (For 2nd Floor) (using ARTIFICIAL SAND). |
| 82 | Providing second class fly ash Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 milimetre diameter / 2 hoop iron strips 25 milimetre X 1.6 milimetre at every third course, properly bent and bounded at ends, scaffolding, racking out joints and watering, excetra complete. (For 3rd Floor) (using ARTIFICIAL SAND). |
| 83 | Providing second class fly ash Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 milimetre diameter / 2 hoop iron strips 25 milimetre X 1.6 milimetre at every third course, properly bent and bounded at ends, scaffolding, racking out joints and watering, excetra complete. (For 4th Floor) (using ARTIFICIAL SAND). |
| 84 | Providing second class fly ash Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 milimetre diameter / 2 hoop iron strips 25 milimetre X 1.6 milimetre at every third course, properly bent and bounded at ends, scaffolding, racking out joints and watering, excetra complete. (For 5th Floor) (using ARTIFICIAL SAND). |
| 85 | Providing second class fly ash Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 milimetre diameter / 2 hoop iron strips 25 milimetre X 1.6 milimetre at every third course, properly bent and bounded at ends, scaffolding, racking out joints and watering, excetra complete. (For 6th Floor) (using ARTIFICIAL SAND). |
| 86 | Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:4 without neeru finish to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). |
| 87 | Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:4 without neeru finish to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (For First Floor) (using ARTIFICIAL SAND). |
| 88 | Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:4 without neeru finish to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (For 2nd Floor) (using ARTIFICIAL SAND). |
| 89 | Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:4 without neeru finish to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (For 3rd Floor) (using ARTIFICIAL SAND). |
| 90 | Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:4 without neeru finish to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (For 4th Floor) (using ARTIFICIAL SAND). |
| 91 | Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:4 without neeru finish to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (For 5th Floor) (using ARTIFICIAL SAND). |
| 92 | Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:4 without neeru finish to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (For 6th Floor) (using ARTIFICIAL SAND). |
| 93 | Providing internal cement plaster 12 milimetre thick in a single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). |
| 94 | Providing internal cement plaster 12 milimetre thick in a single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For First Floor) (using ARTIFICIAL SAND). |
| 95 | Providing internal cement plaster 12 milimetre thick in a single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For 2nd Floor) (using ARTIFICIAL SAND). |
| 96 | Providing internal cement plaster 12 milimetre thick in a single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For 3rd Floor) (using ARTIFICIAL SAND). |
| 97 | Providing internal cement plaster 12 milimetre thick in a single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For 4th Floor) (using ARTIFICIAL SAND). |
| 98 | Providing internal cement plaster 12 milimetre thick in a single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For 5th Floor) (using ARTIFICIAL SAND). |
| 99 | Providing internal cement plaster 12 milimetre thick in a single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For 6th Floor) (using ARTIFICIAL SAND). |
| 100 | Providing and applying plaster with plaster of paris in 6 milimetre thickness to previously plastered surface in all positions including preparing the surface, scaffolding, excetra complete. (For Ground Floor) |
| 101 | Providing and applying plaster with plaster of paris in 6 milimetre thickness to previously plastered surface in all positions including preparing the surface, scaffolding, excetra complete. (For First Floor) |
| 102 | Providing and applying plaster with plaster of paris in 6 milimetre thickness to previously plastered surface in all positions including preparing the surface, scaffolding, excetra complete. (For 2nd Floor) |
| 103 | Providing and applying plaster with plaster of paris in 6 milimetre thickness to previously plastered surface in all positions including preparing the surface, scaffolding, excetra complete. (For 3rd Floor) |
| 104 | Providing and applying plaster with plaster of paris in 6 milimetre thickness to previously plastered surface in all positions including preparing the surface, scaffolding, excetra complete. (For 4th Floor) |
| 105 | Providing and applying plaster with plaster of paris in 6 milimetre thickness to previously plastered surface in all positions including preparing the surface, scaffolding, excetra complete. (For 5th Floor) |
| 106 | Providing and applying plaster with plaster of paris in 6 milimetre thickness to previously plastered surface in all positions including preparing the surface, scaffolding, excetra complete. (For 6th Floor) |
| 107 | Providing waterproof plaster in water closet and bath 12 milimetre thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of one kilogram per bag of cement of approved make and manufacturer and curing, excetra complete. (Excluding Tiles) (For Ground Floor) (using ARTIFICIAL SAND). |
| 108 | Providing waterproof plaster in water closet and bath 12 milimetre thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of one kilogram per bag of cement of approved make and manufacturer and curing, excetra complete. (Excluding Tiles) (For First Floor) (using ARTIFICIAL SAND). |
| 109 | Providing waterproof plaster in water closet and bath 12 milimetre thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of one kilogram per bag of cement of approved make and manufacturer and curing, excetra complete. (Excluding Tiles) (For 2nd Floor) (using ARTIFICIAL SAND). |
| 110 | Providing waterproof plaster in water closet and bath 12 milimetre thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of one kilogram per bag of cement of approved make and manufacturer and curing, excetra complete. (Excluding Tiles) (For 3rd Floor) (using ARTIFICIAL SAND). |
| 111 | Providing waterproof plaster in water closet and bath 12 milimetre thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of one kilogram per bag of cement of approved make and manufacturer and curing, excetra complete. (Excluding Tiles) (For 4th Floor) (using ARTIFICIAL SAND). |
| 112 | Providing waterproof plaster in water closet and bath 12 milimetre thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of one kilogram per bag of cement of approved make and manufacturer and curing, excetra complete. (Excluding Tiles) (For 5th Floor) (using ARTIFICIAL SAND). |
| 113 | Providing waterproof plaster in water closet and bath 12 milimetre thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of one kilogram per bag of cement of approved make and manufacturer and curing, excetra complete. (Excluding Tiles) (For 6th Floor) (using ARTIFICIAL SAND). |
| 114 | Providing and applying two coats of wall care putty on plastered surface and ceiling and walls to prepare surface even and smooth approved make excetra complete. (For Ground Floor) |
| 115 | Providing and applying two coats of wall care putty on plastered surface and ceiling and walls to prepare surface even and smooth approved make excetra complete. (For First Floor) |
| 116 | Providing and applying two coats of wall care putty on plastered surface and ceiling and walls to prepare surface even and smooth approved make excetra complete. (For 2nd Floor) |
| 117 | Providing and applying two coats of wall care putty on plastered surface and ceiling and walls to prepare surface even and smooth approved make excetra complete. (For 3rd Floor) |
| 118 | Providing and applying two coats of wall care putty on plastered surface and ceiling and walls to prepare surface even and smooth approved make excetra complete. (For 4th Floor) |
| 119 | Providing and applying two coats of wall care putty on plastered surface and ceiling and walls to prepare surface even and smooth approved make excetra complete. (For 5th Floor) |
| 120 | Providing and applying two coats of wall care putty on plastered surface and ceiling and walls to prepare surface even and smooth approved make excetra complete. (For 6th Floor) |
| 121 | Labour charges for providing groove in external plaster having width and spaced at as directed by Engineer in-charge, excetra complete. (For Ground Floor) |
| 122 | Labour charges for providing groove in external plaster having width and spaced at as directed by Engineer in-charge, excetra complete. (For First Floor) |
| 123 | Labour charges for providing groove in external plaster having width and spaced at as directed by Engineer in-charge, excetra complete. (For 2nd Floor) |
| 124 | Labour charges for providing groove in external plaster having width and spaced at as directed by Engineer in-charge, excetra complete. (For 3rd Floor) |
| 125 | Labour charges for providing groove in external plaster having width and spaced at as directed by Engineer in-charge, excetra complete. (For 4th Floor) |
| 126 | Labour charges for providing groove in external plaster having width and spaced at as directed by Engineer in-charge, excetra complete. (For 5th Floor) |
| 127 | Labour charges for providing groove in external plaster having width and spaced at as directed by Engineer in-charge, excetra complete. (For 6th Floor) |
| 128 | Providing neeru finish to plastered surfaces in all positions including scaffolding and curing, excetra complete. (For Ground Floor) |
| 129 | Providing neeru finish to plastered surfaces in all positions including scaffolding and curing, excetra complete. (For First Floor) |
| 130 | Providing neeru finish to plastered surfaces in all positions including scaffolding and curing, excetra complete. (For 2nd Floor) |
| 131 | Providing neeru finish to plastered surfaces in all positions including scaffolding and curing, excetra complete. (For 3rd Floor) |
| 132 | Providing neeru finish to plastered surfaces in all positions including scaffolding and curing, excetra complete. (For 4th Floor) |
| 133 | Providing neeru finish to plastered surfaces in all positions including scaffolding and curing, excetra complete. (For 5th Floor) |
| 134 | Providing neeru finish to plastered surfaces in all positions including scaffolding and curing, excetra complete. (For 6th Floor) |
| 135 | Providing and applying texture plaster with finishing with texture material approved make in 3 milimetre to 4 milimetre thickness on previously finished plastered surface including plaster groove 6 milimetre thickness or tape grooves 35 milimetre to 45 milimetre thickness or as required, in all positions including preparing and finishing the surface, scaffolding, excetra complete. (For Ground Floor) |
| 136 | Providing and applying texture plaster with finishing with texture material approved make in 3 milimetre to 4 milimetre thickness on previously finished plastered surface including plaster groove 6 milimetre thickness or tape grooves 35 milimetre to 45 milimetre thickness or as required, in all positions including preparing and finishing the surface, scaffolding, excetra complete. (For First Floor) |
| 137 | Providing and applying texture plaster with finishing with texture material approved make in 3 milimetre to 4 milimetre thickness on previously finished plastered surface including plaster groove 6 milimetre thickness or tape grooves 35 milimetre to 45 milimetre thickness or as required, in all positions including preparing and finishing the surface, scaffolding, excetra complete. (For 2nd Floor) |
| 138 | Providing and applying texture plaster with finishing with texture material approved make in 3 milimetre to 4 milimetre thickness on previously finished plastered surface including plaster groove 6 milimetre thickness or tape grooves 35 milimetre to 45 milimetre thickness or as required, in all positions including preparing and finishing the surface, scaffolding, excetra complete. (For 3rd Floor) |
| 139 | Providing and applying texture plaster with finishing with texture material approved make in 3 milimetre to 4 milimetre thickness on previously finished plastered surface including plaster groove 6 milimetre thickness or tape grooves 35 milimetre to 45 milimetre thickness or as required, in all positions including preparing and finishing the surface, scaffolding, excetra complete. (For 4th Floor) |
| 140 | Providing and applying texture plaster with finishing with texture material approved make in 3 milimetre to 4 milimetre thickness on previously finished plastered surface including plaster groove 6 milimetre thickness or tape grooves 35 milimetre to 45 milimetre thickness or as required, in all positions including preparing and finishing the surface, scaffolding, excetra complete. (For 5th Floor) |
| 141 | Providing and applying texture plaster with finishing with texture material approved make in 3 milimetre to 4 milimetre thickness on previously finished plastered surface including plaster groove 6 milimetre thickness or tape grooves 35 milimetre to 45 milimetre thickness or as required, in all positions including preparing and finishing the surface, scaffolding, excetra complete. (For 6th Floor) |
| 142 | Providing sand faced plaster externally in cement mortar using approved screened sand in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at one killogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment of 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days, scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). |
| 143 | Providing sand faced plaster externally in cement mortar using approved screened sand in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at one killogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment of 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days, scaffolding, excetra complete. (For First Floor) (using ARTIFICIAL SAND). |
| 144 | Providing sand faced plaster externally in cement mortar using approved screened sand in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at one killogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment of 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days, scaffolding, excetra complete. (For 2nd Floor) (using ARTIFICIAL SAND). |
| 145 | Providing sand faced plaster externally in cement mortar using approved screened sand in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at one killogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment of 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days, scaffolding, excetra complete. (For 3rd Floor) (using ARTIFICIAL SAND). |
| 146 | Providing sand faced plaster externally in cement mortar using approved screened sand in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at one killogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment of 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days, scaffolding, excetra complete. (For 4th Floor) (using ARTIFICIAL SAND). |
| 147 | Providing sand faced plaster externally in cement mortar using approved screened sand in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at one killogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment of 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days, scaffolding, excetra complete. (For 5th Floor) (using ARTIFICIAL SAND). |
| 148 | Providing sand faced plaster externally in cement mortar using approved screened sand in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at one killogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment of 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days, scaffolding, excetra complete. (For 6th Floor) (using ARTIFICIAL SAND). |
| 149 | Providing and applying two coats of exterior weather shield paint of approved manufacturer and of approved colour to the plastered surfaces including cleaning, preparing the plaster surfaces, applying primer coat, scaffolding, if necessary and watering the surface for two days, excetra complete. (For Ground Floor) |
| 150 | Providing and applying two coats of exterior weather shield paint of approved manufacturer and of approved colour to the plastered surfaces including cleaning, preparing the plaster surfaces, applying primer coat, scaffolding, if necessary and watering the surface for two days, excetra complete. (For First Floor) |
| 151 | Providing and applying two coats of exterior weather shield paint of approved manufacturer and of approved colour to the plastered surfaces including cleaning, preparing the plaster surfaces, applying primer coat, scaffolding, if necessary and watering the surface for two days, excetra complete. (For 2nd Floor) |
| 152 | Providing and applying two coats of exterior weather shield paint of approved manufacturer and of approved colour to the plastered surfaces including cleaning, preparing the plaster surfaces, applying primer coat, scaffolding, if necessary and watering the surface for two days, excetra complete. (For 3rd Floor) |
| 153 | Providing and applying two coats of exterior weather shield paint of approved manufacturer and of approved colour to the plastered surfaces including cleaning, preparing the plaster surfaces, applying primer coat, scaffolding, if necessary and watering the surface for two days, excetra complete. (For 4th Floor) |
| 154 | Providing and applying two coats of exterior weather shield paint of approved manufacturer and of approved colour to the plastered surfaces including cleaning, preparing the plaster surfaces, applying primer coat, scaffolding, if necessary and watering the surface for two days, excetra complete. (For 5th Floor) |
| 155 | Providing and applying two coats of exterior weather shield paint of approved manufacturer and of approved colour to the plastered surfaces including cleaning, preparing the plaster surfaces, applying primer coat, scaffolding, if necessary and watering the surface for two days, excetra complete. (For 6th Floor) |
| 156 | Providing and applying plaster / wall punning with Plaster of Paris (with Plaster of Paris material of approved make) in 10 milimetre to 13 milimetre thickness to previously plastered surface / or on new brick surface (excluding rough cast plaster) in all positions including preparing and finishing the surface, scaffolding, excetra complete. (For Ground Floor) |
| 157 | Providing and applying plaster / wall punning with Plaster of Paris (with Plaster of Paris material of approved make) in 10 milimetre to 13 milimetre thickness to previously plastered surface / or on new brick surface (excluding rough cast plaster) in all positions including preparing and finishing the surface, scaffolding, excetra complete. (For First Floor) |
| 158 | Providing and applying plaster / wall punning with Plaster of Paris (with Plaster of Paris material of approved make) in 10 milimetre to 13 milimetre thickness to previously plastered surface / or on new brick surface (excluding rough cast plaster) in all positions including preparing and finishing the surface, scaffolding, excetra complete. (For 2nd Floor) |
| 159 | Providing and applying plaster / wall punning with Plaster of Paris (with Plaster of Paris material of approved make) in 10 milimetre to 13 milimetre thickness to previously plastered surface / or on new brick surface (excluding rough cast plaster) in all positions including preparing and finishing the surface, scaffolding, excetra complete. (For 3rd Floor) |
| 160 | Providing and applying plaster / wall punning with Plaster of Paris (with Plaster of Paris material of approved make) in 10 milimetre to 13 milimetre thickness to previously plastered surface / or on new brick surface (excluding rough cast plaster) in all positions including preparing and finishing the surface, scaffolding, excetra complete. (For 4th Floor) |
| 161 | Providing and applying plaster / wall punning with Plaster of Paris (with Plaster of Paris material of approved make) in 10 milimetre to 13 milimetre thickness to previously plastered surface / or on new brick surface (excluding rough cast plaster) in all positions including preparing and finishing the surface, scaffolding, excetra complete. (For 5th Floor) |
| 162 | Providing and applying plaster / wall punning with Plaster of Paris (with Plaster of Paris material of approved make) in 10 milimetre to 13 milimetre thickness to previously plastered surface / or on new brick surface (excluding rough cast plaster) in all positions including preparing and finishing the surface, scaffolding, excetra complete. (For 6th Floor) |
| 163 | Providing patti / band 75 milimetre wide on plastered surface 12 milimetre to 15 milimetre thick in cement mortar 1:3 in line and level including neet finishing, scaffolding, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). |
| 164 | Providing patti / band 75 milimetre wide on plastered surface 12 milimetre to 15 milimetre thick in cement mortar 1:3 in line and level including neet finishing, scaffolding, curing, excetra complete. (For First Floor) (using ARTIFICIAL SAND). |
| 165 | Providing patti / band 75 milimetre wide on plastered surface 12 milimetre to 15 milimetre thick in cement mortar 1:3 in line and level including neet finishing, scaffolding, curing, excetra complete. (For 2nd Floor) (using ARTIFICIAL SAND). |
| 166 | Providing patti / band 75 milimetre wide on plastered surface 12 milimetre to 15 milimetre thick in cement mortar 1:3 in line and level including neet finishing, scaffolding, curing, excetra complete. (For 3rd Floor) (using ARTIFICIAL SAND). |
| 167 | Providing patti / band 75 milimetre wide on plastered surface 12 milimetre to 15 milimetre thick in cement mortar 1:3 in line and level including neet finishing, scaffolding, curing, excetra complete. (For 4th Floor) (using ARTIFICIAL SAND). |
| 168 | Providing patti / band 75 milimetre wide on plastered surface 12 milimetre to 15 milimetre thick in cement mortar 1:3 in line and level including neet finishing, scaffolding, curing, excetra complete. (For 5th Floor) (using ARTIFICIAL SAND). |
| 169 | Providing patti / band 75 milimetre wide on plastered surface 12 milimetre to 15 milimetre thick in cement mortar 1:3 in line and level including neet finishing, scaffolding, curing, excetra complete. (For 6th Floor) (using ARTIFICIAL SAND). |
| 170 | Providing water proof bedding for flooring of bath and water closet 25 milimetre thick in cement mortar 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs. 500/- including ponding test, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). |
| 171 | Providing water proof bedding for flooring of bath and water closet 25 milimetre thick in cement mortar 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs. 500/- including ponding test, excetra complete. (For First Floor) (using ARTIFICIAL SAND). |
| 172 | Providing water proof bedding for flooring of bath and water closet 25 milimetre thick in cement mortar 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs. 500/- including ponding test, excetra complete. (For 2nd Floor) (using ARTIFICIAL SAND). |
| 173 | Providing water proof bedding for flooring of bath and water closet 25 milimetre thick in cement mortar 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs. 500/- including ponding test, excetra complete. (For 3rd Floor) (using ARTIFICIAL SAND). |
| 174 | Providing water proof bedding for flooring of bath and water closet 25 milimetre thick in cement mortar 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs. 500/- including ponding test, excetra complete. (For 4th Floor) (using ARTIFICIAL SAND). |
| 175 | Providing water proof bedding for flooring of bath and water closet 25 milimetre thick in cement mortar 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs. 500/- including ponding test, excetra complete. (For 5th Floor) (using ARTIFICIAL SAND). |
| 176 | Providing water proof bedding for flooring of bath and water closet 25 milimetre thick in cement mortar 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs. 500/- including ponding test, excetra complete. (For 6th Floor) (using ARTIFICIAL SAND). |
| 177 | Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of reinforced cement concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / burnt brick masonry and or tying by binding wire, excetra complete. (For Ground Floor) |
| 178 | Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of reinforced cement concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / burnt brick masonry and or tying by binding wire, excetra complete. (For First Floor) |
| 179 | Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of reinforced cement concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / burnt brick masonry and or tying by binding wire, excetra complete. (For 2nd Floor) |
| 180 | Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of reinforced cement concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / burnt brick masonry and or tying by binding wire, excetra complete. (For 3rd Floor) |
| 181 | Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of reinforced cement concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / burnt brick masonry and or tying by binding wire, excetra complete. (For 4th Floor) |
| 182 | Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of reinforced cement concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / burnt brick masonry and or tying by binding wire, excetra complete. (For 5th Floor) |
| 183 | Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of reinforced cement concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / burnt brick masonry and or tying by binding wire, excetra complete. (For 6th Floor) |
| 184 | Providing and applying pearl / luster finish paint of approved colour and shade to the existing plastered surface including scaffolding, preparing the surface, applying the acrylic wall putti, excetra complete. (For Ground Floor) |
| 185 | Providing and applying pearl / luster finish paint of approved colour and shade to the existing plastered surface including scaffolding, preparing the surface, applying the acrylic wall putti, excetra complete. (For First Floor) |
| 186 | Providing and applying pearl / luster finish paint of approved colour and shade to the existing plastered surface including scaffolding, preparing the surface, applying the acrylic wall putti, excetra complete. (For 2nd Floor) |
| 187 | Providing and applying pearl / luster finish paint of approved colour and shade to the existing plastered surface including scaffolding, preparing the surface, applying the acrylic wall putti, excetra complete. (For 3rd Floor) |
| 188 | Providing and applying pearl / luster finish paint of approved colour and shade to the existing plastered surface including scaffolding, preparing the surface, applying the acrylic wall putti, excetra complete. (For 4th Floor) |
| 189 | Providing and applying pearl / luster finish paint of approved colour and shade to the existing plastered surface including scaffolding, preparing the surface, applying the acrylic wall putti, excetra complete. (For 5th Floor) |
| 190 | Providing and applying pearl / luster finish paint of approved colour and shade to the existing plastered surface including scaffolding, preparing the surface, applying the acrylic wall putti, excetra complete. (For 6th Floor) |
| 191 | Providing and laying ceramic tiles of having sizes 30 centimetre X 60 centimetre and confirming to corrosponding Indian Standard for dado and skirting in required position with ready made adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white / colour cement slurry, cleanding, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). |
| 192 | Providing and laying ceramic tiles of having sizes 30 centimetre X 60 centimetre and confirming to corrosponding Indian Standard for dado and skirting in required position with ready made adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white / colour cement slurry, cleanding, curing, excetra complete. (For First Floor) (using ARTIFICIAL SAND). |
| 193 | Providing and laying ceramic tiles of having sizes 30 centimetre X 60 centimetre and confirming to corrosponding Indian Standard for dado and skirting in required position with ready made adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white / colour cement slurry, cleanding, curing, excetra complete. (For 2nd Floor) (using ARTIFICIAL SAND). |
| 194 | Providing and laying ceramic tiles of having sizes 30 centimetre X 60 centimetre and confirming to corrosponding Indian Standard for dado and skirting in required position with ready made adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white / colour cement slurry, cleanding, curing, excetra complete. (For 3rd Floor) (using ARTIFICIAL SAND). |
| 195 | Providing and laying ceramic tiles of having sizes 30 centimetre X 60 centimetre and confirming to corrosponding Indian Standard for dado and skirting in required position with ready made adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white / colour cement slurry, cleanding, curing, excetra complete. (For 4th Floor) (using ARTIFICIAL SAND). |
| 196 | Providing and laying ceramic tiles of having sizes 30 centimetre X 60 centimetre and confirming to corrosponding Indian Standard for dado and skirting in required position with ready made adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white / colour cement slurry, cleanding, curing, excetra complete. (For 5th Floor) (using ARTIFICIAL SAND). |
| 197 | Providing and laying ceramic tiles of having sizes 30 centimetre X 60 centimetre and confirming to corrosponding Indian Standard for dado and skirting in required position with ready made adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white / colour cement slurry, cleanding, curing, excetra complete. (For 6th Floor) (using ARTIFICIAL SAND). |
| 198 | Providing and laying antiskid ceramic tiles of approved quality of size 30 centimetre X 30 centimetre and confirming to Indian Standard 15622:2006 (Group BIIa) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). |
| 199 | Providing and laying antiskid ceramic tiles of approved quality of size 30 centimetre X 30 centimetre and confirming to Indian Standard 15622:2006 (Group BIIa) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning, curing, excetra complete. (For First Floor) (using ARTIFICIAL SAND). |
| 200 | Providing and laying antiskid ceramic tiles of approved quality of size 30 centimetre X 30 centimetre and confirming to Indian Standard 15622:2006 (Group BIIa) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning, curing, excetra complete. (For 2nd Floor) (using ARTIFICIAL SAND). |
| 201 | Providing and laying antiskid ceramic tiles of approved quality of size 30 centimetre X 30 centimetre and confirming to Indian Standard 15622:2006 (Group BIIa) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning, curing, excetra complete. (For 3rd Floor) (using ARTIFICIAL SAND). |
| 202 | Providing and laying antiskid ceramic tiles of approved quality of size 30 centimetre X 30 centimetre and confirming to Indian Standard 15622:2006 (Group BIIa) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning, curing, excetra complete. (For 4th Floor) (using ARTIFICIAL SAND). |
| 203 | Providing and laying antiskid ceramic tiles of approved quality of size 30 centimetre X 30 centimetre and confirming to Indian Standard 15622:2006 (Group BIIa) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning, curing, excetra complete. (For 5th Floor) (using ARTIFICIAL SAND). |
| 204 | Providing and laying antiskid ceramic tiles of approved quality of size 30 centimetre X 30 centimetre and confirming to Indian Standard 15622:2006 (Group BIIa) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning, curing, excetra complete. (For 6th Floor) (using ARTIFICIAL SAND). |
| 205 | Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on a bed of 1:4 cement mortar including float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). |
| 206 | Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on a bed of 1:4 cement mortar including float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For First Floor) (using ARTIFICIAL SAND). |
| 207 | Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on a bed of 1:4 cement mortar including float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For 2nd Floor) (using ARTIFICIAL SAND). |
| 208 | Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on a bed of 1:4 cement mortar including float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For 3rd Floor) (using ARTIFICIAL SAND). |
| 209 | Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on a bed of 1:4 cement mortar including float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For 4th Floor) (using ARTIFICIAL SAND). |
| 210 | Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on a bed of 1:4 cement mortar including float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For 5th Floor) (using ARTIFICIAL SAND). |
| 211 | Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on a bed of 1:4 cement mortar including float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For 6th Floor) (using ARTIFICIAL SAND). |
| 212 | Providing and laying machine cut machine polished Kotah stone flooring 25 milimetre to 30 milimetre thick in required width in plain / diamond pattern on bed of 1:6 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). |
| 213 | Providing and laying machine cut machine polished Kotah stone flooring 25 milimetre to 30 milimetre thick in required width in plain / diamond pattern on bed of 1:6 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For First Floor) (using ARTIFICIAL SAND). |
| 214 | Providing and laying machine cut machine polished Kotah stone flooring 25 milimetre to 30 milimetre thick in required width in plain / diamond pattern on bed of 1:6 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For 2nd Floor) (using ARTIFICIAL SAND). |
| 215 | Providing and laying machine cut machine polished Kotah stone flooring 25 milimetre to 30 milimetre thick in required width in plain / diamond pattern on bed of 1:6 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For 3rd Floor) (using ARTIFICIAL SAND). |
| 216 | Providing and laying machine cut machine polished Kotah stone flooring 25 milimetre to 30 milimetre thick in required width in plain / diamond pattern on bed of 1:6 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For 4th Floor) (using ARTIFICIAL SAND). |
| 217 | Providing and laying machine cut machine polished Kotah stone flooring 25 milimetre to 30 milimetre thick in required width in plain / diamond pattern on bed of 1:6 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For 5th Floor) (using ARTIFICIAL SAND). |
| 218 | Providing and laying machine cut machine polished Kotah stone flooring 25 milimetre to 30 milimetre thick in required width in plain / diamond pattern on bed of 1:6 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For 6th Floor) (using ARTIFICIAL SAND). |
| 219 | Providing and preparing kitchen otta up to 75 centimetre width, made up from 30 milimetre thick and 75 centimetre high vertical support for Kadappa at one metre center to center of 25 milimetre thick both side polished Kadappa middle shelf and bottom of 20 milimetre thick one side polished Kadappa with facia patti of 20 milimetre X 50 milimetre Kadappa including all material, labour, cutting, fixing with cement mortar and araldite, all material labour cutting fixing with cement mortar and araldite curing polished and cleaning excetra complete. (For Ground Floor) |
| 220 | Providing leather finished polishing to granite stone slab by continuous grinding in four coats of different bits to receive rough and matty finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing, excetra complete. (For Ground Floor) |
| 221 | Providing leather finished polishing to granite stone slab by continuous grinding in four coats of different bits to receive rough and matty finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing, excetra complete. (For First Floor) |
| 222 | Providing leather finished polishing to granite stone slab by continuous grinding in four coats of different bits to receive rough and matty finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing, excetra complete. (For 2nd Floor) |
| 223 | Providing leather finished polishing to granite stone slab by continuous grinding in four coats of different bits to receive rough and matty finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing, excetra complete. (For 3rd Floor) |
| 224 | Providing leather finished polishing to granite stone slab by continuous grinding in four coats of different bits to receive rough and matty finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing, excetra complete. (For 4th Floor) |
| 225 | Providing leather finished polishing to granite stone slab by continuous grinding in four coats of different bits to receive rough and matty finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing, excetra complete. (For 5th Floor) |
| 226 | Providing leather finished polishing to granite stone slab by continuous grinding in four coats of different bits to receive rough and matty finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing, excetra complete. (For 6th Floor) |
| 227 | Providing and laying in position flooring of telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on a bed of 1:6 cement mortar including cement float, striking joints, pointing in cement mortar 1:3, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). |
| 228 | Providing and laying in position flooring of telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on a bed of 1:6 cement mortar including cement float, striking joints, pointing in cement mortar 1:3, curing and cleaning, excetra complete. (For First Floor) (using ARTIFICIAL SAND). |
| 229 | Providing and laying in position flooring of telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on a bed of 1:6 cement mortar including cement float, striking joints, pointing in cement mortar 1:3, curing and cleaning, excetra complete. (For 2nd Floor) (using ARTIFICIAL SAND). |
| 230 | Providing and laying in position flooring of telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on a bed of 1:6 cement mortar including cement float, striking joints, pointing in cement mortar 1:3, curing and cleaning, excetra complete. (For 3rd Floor) (using ARTIFICIAL SAND). |
| 231 | Providing and laying in position flooring of telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on a bed of 1:6 cement mortar including cement float, striking joints, pointing in cement mortar 1:3, curing and cleaning, excetra complete. (For 4th Floor) (using ARTIFICIAL SAND). |
| 232 | Providing and laying in position flooring of telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on a bed of 1:6 cement mortar including cement float, striking joints, pointing in cement mortar 1:3, curing and cleaning, excetra complete. (For 5th Floor) (using ARTIFICIAL SAND). |
| 233 | Providing and laying in position flooring of telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on a bed of 1:6 cement mortar including cement float, striking joints, pointing in cement mortar 1:3, curing and cleaning, excetra complete. (For 6th Floor) (using ARTIFICIAL SAND). |
| 234 | Providing and laying telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of 18 milimetre to 20 milimetre thick for door frame / dado / window boxing, excetra on cement mortar 1:6 including filling joints with polymer base filler, nosing the sharp edges wherever necessary, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). |
| 235 | Providing and laying telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of 18 milimetre to 20 milimetre thick for door frame / dado / window boxing, excetra on cement mortar 1:6 including filling joints with polymer base filler, nosing the sharp edges wherever necessary, curing, excetra complete. (For First Floor) (using ARTIFICIAL SAND). |
| 236 | Providing and laying telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of 18 milimetre to 20 milimetre thick for door frame / dado / window boxing, excetra on cement mortar 1:6 including filling joints with polymer base filler, nosing the sharp edges wherever necessary, curing, excetra complete. (For 2nd Floor) (using ARTIFICIAL SAND). |
| 237 | Providing and laying telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of 18 milimetre to 20 milimetre thick for door frame / dado / window boxing, excetra on cement mortar 1:6 including filling joints with polymer base filler, nosing the sharp edges wherever necessary, curing, excetra complete. (For 3rd Floor) (using ARTIFICIAL SAND). |
| 238 | Providing and laying telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of 18 milimetre to 20 milimetre thick for door frame / dado / window boxing, excetra on cement mortar 1:6 including filling joints with polymer base filler, nosing the sharp edges wherever necessary, curing, excetra complete. (For 4th Floor) (using ARTIFICIAL SAND). |
| 239 | Providing and laying telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of 18 milimetre to 20 milimetre thick for door frame / dado / window boxing, excetra on cement mortar 1:6 including filling joints with polymer base filler, nosing the sharp edges wherever necessary, curing, excetra complete. (For 5th Floor) (using ARTIFICIAL SAND). |
| 240 | Providing and laying telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of 18 milimetre to 20 milimetre thick for door frame / dado / window boxing, excetra on cement mortar 1:6 including filling joints with polymer base filler, nosing the sharp edges wherever necessary, curing, excetra complete. (For 6th Floor) (using ARTIFICIAL SAND). |
| 241 | Providing and fixing frame with / without ventilator of size as specified with country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 milimetre X 40 milimetre X 5 milimetre with oil painting, excetra complete. (For Ground Floor) |
| 242 | Providing and fixing frame with / without ventilator of size as specified with country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 milimetre X 40 milimetre X 5 milimetre with oil painting, excetra complete. (For First Floor) |
| 243 | Providing and fixing frame with / without ventilator of size as specified with country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 milimetre X 40 milimetre X 5 milimetre with oil painting, excetra complete. (For 2nd Floor) |
| 244 | Providing and fixing frame with / without ventilator of size as specified with country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 milimetre X 40 milimetre X 5 milimetre with oil painting, excetra complete. (For 3rd Floor) |
| 245 | Providing and fixing frame with / without ventilator of size as specified with country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 milimetre X 40 milimetre X 5 milimetre with oil painting, excetra complete. (For 4th Floor) |
| 246 | Providing and fixing frame with / without ventilator of size as specified with country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 milimetre X 40 milimetre X 5 milimetre with oil painting, excetra complete. (For 5th Floor) |
| 247 | Providing and fixing frame with / without ventilator of size as specified with country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 milimetre X 40 milimetre X 5 milimetre with oil painting, excetra complete. (For 6th Floor) |
| 248 | Providing and fixing country cut teak wood double or single leaf second class fully panelled door shutter with 35 milimetre thick and style and rail 25 milimetre thick pannels with openable fan light as per detailed drawings, excluding the door frame 60 milimetre X 100 milimetre including stainless steel fixrtures and fastening and finishing the wood work with oil painting three coats, excetra complete.(Excluding the door frame) (For Ground Floor) |
| 249 | Providing and fixing country cut teak wood double or single leaf second class fully panelled door shutter with 35 milimetre thick and style and rail 25 milimetre thick pannels with openable fan light as per detailed drawings, excluding the door frame 60 milimetre X 100 milimetre including stainless steel fixrtures and fastening and finishing the wood work with oil painting three coats, excetra complete.(Excluding the door frame) (For First Floor) |
| 250 | Providing and fixing country cut teak wood double or single leaf second class fully panelled door shutter with 35 milimetre thick and style and rail 25 milimetre thick pannels with openable fan light as per detailed drawings, excluding the door frame 60 milimetre X 100 milimetre including stainless steel fixrtures and fastening and finishing the wood work with oil painting three coats, excetra complete.(Excluding the door frame) (For 2nd Floor) |
| 251 | Providing and fixing country cut teak wood double or single leaf second class fully panelled door shutter with 35 milimetre thick and style and rail 25 milimetre thick pannels with openable fan light as per detailed drawings, excluding the door frame 60 milimetre X 100 milimetre including stainless steel fixrtures and fastening and finishing the wood work with oil painting three coats, excetra complete.(Excluding the door frame) (For 3rd Floor) |
| 252 | Providing and fixing country cut teak wood double or single leaf second class fully panelled door shutter with 35 milimetre thick and style and rail 25 milimetre thick pannels with openable fan light as per detailed drawings, excluding the door frame 60 milimetre X 100 milimetre including stainless steel fixrtures and fastening and finishing the wood work with oil painting three coats, excetra complete.(Excluding the door frame) (For 4th Floor) |
| 253 | Providing and fixing country cut teak wood double or single leaf second class fully panelled door shutter with 35 milimetre thick and style and rail 25 milimetre thick pannels with openable fan light as per detailed drawings, excluding the door frame 60 milimetre X 100 milimetre including stainless steel fixrtures and fastening and finishing the wood work with oil painting three coats, excetra complete.(Excluding the door frame) (For 5th Floor) |
| 254 | Providing and fixing country cut teak wood double or single leaf second class fully panelled door shutter with 35 milimetre thick and style and rail 25 milimetre thick pannels with openable fan light as per detailed drawings, excluding the door frame 60 milimetre X 100 milimetre including stainless steel fixrtures and fastening and finishing the wood work with oil painting three coats, excetra complete.(Excluding the door frame) (For 6th Floor) |
| 255 | Providing and fixing solid core flush door shutter in single leaf 32 milimetre thick decorative type of exterior grade as per detailed drawings, approved face veneers 3 milimetre thick on both faces or as directed, all necessary beeds, moulding and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides and finishing with french polish, excetra complete. (For Ground Floor) |
| 256 | Providing and fixing solid core flush door shutter in single leaf 32 milimetre thick decorative type of exterior grade as per detailed drawings, approved face veneers 3 milimetre thick on both faces or as directed, all necessary beeds, moulding and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides and finishing with french polish, excetra complete. (For First Floor) |
| 257 | Providing and fixing solid core flush door shutter in single leaf 32 milimetre thick decorative type of exterior grade as per detailed drawings, approved face veneers 3 milimetre thick on both faces or as directed, all necessary beeds, moulding and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides and finishing with french polish, excetra complete. (For 2nd Floor) |
| 258 | Providing and fixing solid core flush door shutter in single leaf 32 milimetre thick decorative type of exterior grade as per detailed drawings, approved face veneers 3 milimetre thick on both faces or as directed, all necessary beeds, moulding and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides and finishing with french polish, excetra complete. (For 3rd Floor) |
| 259 | Providing and fixing solid core flush door shutter in single leaf 32 milimetre thick decorative type of exterior grade as per detailed drawings, approved face veneers 3 milimetre thick on both faces or as directed, all necessary beeds, moulding and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides and finishing with french polish, excetra complete. (For 4th Floor) |
| 260 | Providing and fixing solid core flush door shutter in single leaf 32 milimetre thick decorative type of exterior grade as per detailed drawings, approved face veneers 3 milimetre thick on both faces or as directed, all necessary beeds, moulding and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides and finishing with french polish, excetra complete. (For 5th Floor) |
| 261 | Providing and fixing solid core flush door shutter in single leaf 32 milimetre thick decorative type of exterior grade as per detailed drawings, approved face veneers 3 milimetre thick on both faces or as directed, all necessary beeds, moulding and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides and finishing with french polish, excetra complete. (For 6th Floor) |
| 262 | Providing and fixing 30 milimetre thick both side prelaminated solid panel polyvinyl chloride door shutter consisting of frame made out of mild steel tube of 19 gauge thickness and size 19 milimetre X 19 milimetre for styles and 15 milimetre X 15 milimetre for top and bottom rails, mild steel frame shall have a coat of metel primer of approved make and manufacture. Mild steel frame shall be covered with heat mouled polyvinyl chloride \"C\" channel made from 5 milimetre (+/0.25) thick prelaminated sheet of density 600 kilogram per cubic metre, of size 30 milimetre thickness 70 milimetre width out of which 50 milimetre shall be flat and 20 milimetre shall be tapered in 45 degree angle on either side forming stiles; and 5 milimetre thick, 95 milimetre wide polyvinyl chloride sheet out of which 75 milimetre shall be flat and 20 milimetre shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 milimetre wide polyvinyl chloride sheet out of which 75 milimetre shall be flat and 20 milimetre shall be tapered on both sides to form lock rail. Top, bottom and lock rail shall be provided either side of the panel. An additional 5 milimetre (+/0.25) thick polyvinyl chloride strip of 20 milimetre width is to be stuck on the bottom side of the \"C\" channel prelaminated paneling of 5 milimetre (+/0.25) thick polyvinyl chloride sheet to be fitted inside the mild steel frame welded / sealed to the styles and rails with 5 milimetre (+/0.25) X 30 milimetre polyvinyl chloride sheet beading on either side and joined together with solvent cement adhesive, excetra 10 milimetre thickness (5 milimetre (+/0.25) X 2 numbers) 20 milimetre wide cross polyvinyl chloride sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 numbers mild steel powder coated butt hinges of size 100 milimetre X 25 milimetre X 2 milimetre using 32 milimetre long steel screws drilled suitable to pass through both the walls of the mild steel tube. Other hardwares should be fixed with 19 milimetre X 6 milimetre size steel screws including fixture fasting. Complete as per direction of Engineer in-charge. (For Ground Floor) |
| 263 | Providing and fixing 30 milimetre thick both side prelaminated solid panel polyvinyl chloride door shutter consisting of frame made out of mild steel tube of 19 gauge thickness and size 19 milimetre X 19 milimetre for styles and 15 milimetre X 15 milimetre for top and bottom rails, mild steel frame shall have a coat of metel primer of approved make and manufacture. Mild steel frame shall be covered with heat mouled polyvinyl chloride \"C\" channel made from 5 milimetre (+/0.25) thick prelaminated sheet of density 600 kilogram per cubic metre, of size 30 milimetre thickness 70 milimetre width out of which 50 milimetre shall be flat and 20 milimetre shall be tapered in 45 degree angle on either side forming stiles; and 5 milimetre thick, 95 milimetre wide polyvinyl chloride sheet out of which 75 milimetre shall be flat and 20 milimetre shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 milimetre wide polyvinyl chloride sheet out of which 75 milimetre shall be flat and 20 milimetre shall be tapered on both sides to form lock rail. Top, bottom and lock rail shall be provided either side of the panel. An additional 5 milimetre (+/0.25) thick polyvinyl chloride strip of 20 milimetre width is to be stuck on the bottom side of the \"C\" channel prelaminated paneling of 5 milimetre (+/0.25) thick polyvinyl chloride sheet to be fitted inside the mild steel frame welded / sealed to the styles and rails with 5 milimetre (+/0.25) X 30 milimetre polyvinyl chloride sheet beading on either side and joined together with solvent cement adhesive, excetra 10 milimetre thickness (5 milimetre (+/0.25) X 2 numbers) 20 milimetre wide cross polyvinyl chloride sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 numbers mild steel powder coated butt hinges of size 100 milimetre X 25 milimetre X 2 milimetre using 32 milimetre long steel screws drilled suitable to pass through both the walls of the mild steel tube. Other hardwares should be fixed with 19 milimetre X 6 milimetre size steel screws including fixture fasting. Complete as per direction of Engineer in-charge. (For First Floor) |
| 264 | Providing and fixing 30 milimetre thick both side prelaminated solid panel polyvinyl chloride door shutter consisting of frame made out of mild steel tube of 19 gauge thickness and size 19 milimetre X 19 milimetre for styles and 15 milimetre X 15 milimetre for top and bottom rails, mild steel frame shall have a coat of metel primer of approved make and manufacture. Mild steel frame shall be covered with heat mouled polyvinyl chloride \"C\" channel made from 5 milimetre (+/0.25) thick prelaminated sheet of density 600 kilogram per cubic metre, of size 30 milimetre thickness 70 milimetre width out of which 50 milimetre shall be flat and 20 milimetre shall be tapered in 45 degree angle on either side forming stiles; and 5 milimetre thick, 95 milimetre wide polyvinyl chloride sheet out of which 75 milimetre shall be flat and 20 milimetre shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 milimetre wide polyvinyl chloride sheet out of which 75 milimetre shall be flat and 20 milimetre shall be tapered on both sides to form lock rail. Top, bottom and lock rail shall be provided either side of the panel. An additional 5 milimetre (+/0.25) thick polyvinyl chloride strip of 20 milimetre width is to be stuck on the bottom side of the \"C\" channel prelaminated paneling of 5 milimetre (+/0.25) thick polyvinyl chloride sheet to be fitted inside the mild steel frame welded / sealed to the styles and rails with 5 milimetre (+/0.25) X 30 milimetre polyvinyl chloride sheet beading on either side and joined together with solvent cement adhesive, excetra 10 milimetre thickness (5 milimetre (+/0.25) X 2 numbers) 20 milimetre wide cross polyvinyl chloride sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 numbers mild steel powder coated butt hinges of size 100 milimetre X 25 milimetre X 2 milimetre using 32 milimetre long steel screws drilled suitable to pass through both the walls of the mild steel tube. Other hardwares should be fixed with 19 milimetre X 6 milimetre size steel screws including fixture fasting. Complete as per direction of Engineer in-charge. (For 2nd Floor) |
| 265 | Providing and fixing 30 milimetre thick both side prelaminated solid panel polyvinyl chloride door shutter consisting of frame made out of mild steel tube of 19 gauge thickness and size 19 milimetre X 19 milimetre for styles and 15 milimetre X 15 milimetre for top and bottom rails, mild steel frame shall have a coat of metel primer of approved make and manufacture. Mild steel frame shall be covered with heat mouled polyvinyl chloride \"C\" channel made from 5 milimetre (+/0.25) thick prelaminated sheet of density 600 kilogram per cubic metre, of size 30 milimetre thickness 70 milimetre width out of which 50 milimetre shall be flat and 20 milimetre shall be tapered in 45 degree angle on either side forming stiles; and 5 milimetre thick, 95 milimetre wide polyvinyl chloride sheet out of which 75 milimetre shall be flat and 20 milimetre shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 milimetre wide polyvinyl chloride sheet out of which 75 milimetre shall be flat and 20 milimetre shall be tapered on both sides to form lock rail. Top, bottom and lock rail shall be provided either side of the panel. An additional 5 milimetre (+/0.25) thick polyvinyl chloride strip of 20 milimetre width is to be stuck on the bottom side of the \"C\" channel prelaminated paneling of 5 milimetre (+/0.25) thick polyvinyl chloride sheet to be fitted inside the mild steel frame welded / sealed to the styles and rails with 5 milimetre (+/0.25) X 30 milimetre polyvinyl chloride sheet beading on either side and joined together with solvent cement adhesive, excetra 10 milimetre thickness (5 milimetre (+/0.25) X 2 numbers) 20 milimetre wide cross polyvinyl chloride sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 numbers mild steel powder coated butt hinges of size 100 milimetre X 25 milimetre X 2 milimetre using 32 milimetre long steel screws drilled suitable to pass through both the walls of the mild steel tube. Other hardwares should be fixed with 19 milimetre X 6 milimetre size steel screws including fixture fasting. Complete as per direction of Engineer in-charge. (For 3rd Floor) |
| 266 | Providing and fixing 30 milimetre thick both side prelaminated solid panel polyvinyl chloride door shutter consisting of frame made out of mild steel tube of 19 gauge thickness and size 19 milimetre X 19 milimetre for styles and 15 milimetre X 15 milimetre for top and bottom rails, mild steel frame shall have a coat of metel primer of approved make and manufacture. Mild steel frame shall be covered with heat mouled polyvinyl chloride \"C\" channel made from 5 milimetre (+/0.25) thick prelaminated sheet of density 600 kilogram per cubic metre, of size 30 milimetre thickness 70 milimetre width out of which 50 milimetre shall be flat and 20 milimetre shall be tapered in 45 degree angle on either side forming stiles; and 5 milimetre thick, 95 milimetre wide polyvinyl chloride sheet out of which 75 milimetre shall be flat and 20 milimetre shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 milimetre wide polyvinyl chloride sheet out of which 75 milimetre shall be flat and 20 milimetre shall be tapered on both sides to form lock rail. Top, bottom and lock rail shall be provided either side of the panel. An additional 5 milimetre (+/0.25) thick polyvinyl chloride strip of 20 milimetre width is to be stuck on the bottom side of the \"C\" channel prelaminated paneling of 5 milimetre (+/0.25) thick polyvinyl chloride sheet to be fitted inside the mild steel frame welded / sealed to the styles and rails with 5 milimetre (+/0.25) X 30 milimetre polyvinyl chloride sheet beading on either side and joined together with solvent cement adhesive, excetra 10 milimetre thickness (5 milimetre (+/0.25) X 2 numbers) 20 milimetre wide cross polyvinyl chloride sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 numbers mild steel powder coated butt hinges of size 100 milimetre X 25 milimetre X 2 milimetre using 32 milimetre long steel screws drilled suitable to pass through both the walls of the mild steel tube. Other hardwares should be fixed with 19 milimetre X 6 milimetre size steel screws including fixture fasting. Complete as per direction of Engineer in-charge. (For 4th Floor) |
| 267 | Providing and fixing 30 milimetre thick both side prelaminated solid panel polyvinyl chloride door shutter consisting of frame made out of mild steel tube of 19 gauge thickness and size 19 milimetre X 19 milimetre for styles and 15 milimetre X 15 milimetre for top and bottom rails, mild steel frame shall have a coat of metel primer of approved make and manufacture. Mild steel frame shall be covered with heat mouled polyvinyl chloride \"C\" channel made from 5 milimetre (+/0.25) thick prelaminated sheet of density 600 kilogram per cubic metre, of size 30 milimetre thickness 70 milimetre width out of which 50 milimetre shall be flat and 20 milimetre shall be tapered in 45 degree angle on either side forming stiles; and 5 milimetre thick, 95 milimetre wide polyvinyl chloride sheet out of which 75 milimetre shall be flat and 20 milimetre shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 milimetre wide polyvinyl chloride sheet out of which 75 milimetre shall be flat and 20 milimetre shall be tapered on both sides to form lock rail. Top, bottom and lock rail shall be provided either side of the panel. An additional 5 milimetre (+/0.25) thick polyvinyl chloride strip of 20 milimetre width is to be stuck on the bottom side of the \"C\" channel prelaminated paneling of 5 milimetre (+/0.25) thick polyvinyl chloride sheet to be fitted inside the mild steel frame welded / sealed to the styles and rails with 5 milimetre (+/0.25) X 30 milimetre polyvinyl chloride sheet beading on either side and joined together with solvent cement adhesive, excetra 10 milimetre thickness (5 milimetre (+/0.25) X 2 numbers) 20 milimetre wide cross polyvinyl chloride sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 numbers mild steel powder coated butt hinges of size 100 milimetre X 25 milimetre X 2 milimetre using 32 milimetre long steel screws drilled suitable to pass through both the walls of the mild steel tube. Other hardwares should be fixed with 19 milimetre X 6 milimetre size steel screws including fixture fasting. Complete as per direction of Engineer in-charge. (For 5th Floor) |
| 268 | Providing and fixing 30 milimetre thick both side prelaminated solid panel polyvinyl chloride door shutter consisting of frame made out of mild steel tube of 19 gauge thickness and size 19 milimetre X 19 milimetre for styles and 15 milimetre X 15 milimetre for top and bottom rails, mild steel frame shall have a coat of metel primer of approved make and manufacture. Mild steel frame shall be covered with heat mouled polyvinyl chloride \"C\" channel made from 5 milimetre (+/0.25) thick prelaminated sheet of density 600 kilogram per cubic metre, of size 30 milimetre thickness 70 milimetre width out of which 50 milimetre shall be flat and 20 milimetre shall be tapered in 45 degree angle on either side forming stiles; and 5 milimetre thick, 95 milimetre wide polyvinyl chloride sheet out of which 75 milimetre shall be flat and 20 milimetre shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 milimetre wide polyvinyl chloride sheet out of which 75 milimetre shall be flat and 20 milimetre shall be tapered on both sides to form lock rail. Top, bottom and lock rail shall be provided either side of the panel. An additional 5 milimetre (+/0.25) thick polyvinyl chloride strip of 20 milimetre width is to be stuck on the bottom side of the \"C\" channel prelaminated paneling of 5 milimetre (+/0.25) thick polyvinyl chloride sheet to be fitted inside the mild steel frame welded / sealed to the styles and rails with 5 milimetre (+/0.25) X 30 milimetre polyvinyl chloride sheet beading on either side and joined together with solvent cement adhesive, excetra 10 milimetre thickness (5 milimetre (+/0.25) X 2 numbers) 20 milimetre wide cross polyvinyl chloride sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 numbers mild steel powder coated butt hinges of size 100 milimetre X 25 milimetre X 2 milimetre using 32 milimetre long steel screws drilled suitable to pass through both the walls of the mild steel tube. Other hardwares should be fixed with 19 milimetre X 6 milimetre size steel screws including fixture fasting. Complete as per direction of Engineer in-charge. (For 6th Floor) |
| 269 | Providing and fixing mild steel grill door 24 kilogram per square metre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and three coats of oil painting, excetra complete. (For Ground Floor) |
| 270 | Providing and fixing mild steel grill door 24 kilogram per square metre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and three coats of oil painting, excetra complete. (For First Floor) |
| 271 | Providing and fixing mild steel grill door 24 kilogram per square metre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and three coats of oil painting, excetra complete. (For 2nd Floor) |
| 272 | Providing and fixing mild steel grill door 24 kilogram per square metre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and three coats of oil painting, excetra complete. (For 3rd Floor) |
| 273 | Providing and fixing mild steel grill door 24 kilogram per square metre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and three coats of oil painting, excetra complete. (For 4th Floor) |
| 274 | Providing and fixing mild steel grill door 24 kilogram per square metre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and three coats of oil painting, excetra complete. (For 5th Floor) |
| 275 | Providing and fixing mild steel grill door 24 kilogram per square metre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and three coats of oil painting, excetra complete. (For 6th Floor) |
| 276 | Providing and fixing collapsible steel gate in one / two leaves with hot rolled vertical channels of 18 milimetre X 9 milimetre X 3 milimetre minimum size, crossings of mild steel flats of size 18 milimetre X 5 milimetre T or E section for runner of minimum 40 milimetre X 6 milimetre size for flange, mild steel flat for top runner of minimum size 40 milimetre X 12 milimetre with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 milimetre, maximum spacing of vertical channels be 100 milimetre enclosed gate position and clear space of 150 milimetre between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer and oil painting, excetra complete. (Indian Standard : 10521-1983). (For Ground Floor) |
| 277 | Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of two tracks with rectangular pipe having overall dimentsions 63.50 milimetre X 38.10 milimetre X 1.02 milimetre at weight 0.547 kilogram per running metre and window frame bottom track section 61.85 milimetre X 31.75 milimetre X 1.20 milimetre at weight 0.695 kilogram per running metre. Top and side track section 61.85 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.659 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass with all required screws and nuts, excetra complete. - With colour anodising with box. (For Ground Floor) |
| 278 | Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of two tracks with rectangular pipe having overall dimentsions 63.50 milimetre X 38.10 milimetre X 1.02 milimetre at weight 0.547 kilogram per running metre and window frame bottom track section 61.85 milimetre X 31.75 milimetre X 1.20 milimetre at weight 0.695 kilogram per running metre. Top and side track section 61.85 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.659 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass with all required screws and nuts, excetra complete. - With colour anodising with box. (For First Floor) |
| 279 | Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of two tracks with rectangular pipe having overall dimentsions 63.50 milimetre X 38.10 milimetre X 1.02 milimetre at weight 0.547 kilogram per running metre and window frame bottom track section 61.85 milimetre X 31.75 milimetre X 1.20 milimetre at weight 0.695 kilogram per running metre. Top and side track section 61.85 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.659 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass with all required screws and nuts, excetra complete. - With colour anodising with box. (For 2nd Floor) |
| 280 | Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of two tracks with rectangular pipe having overall dimentsions 63.50 milimetre X 38.10 milimetre X 1.02 milimetre at weight 0.547 kilogram per running metre and window frame bottom track section 61.85 milimetre X 31.75 milimetre X 1.20 milimetre at weight 0.695 kilogram per running metre. Top and side track section 61.85 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.659 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass with all required screws and nuts, excetra complete. - With colour anodising with box. (For 3rd Floor) |
| 281 | Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of two tracks with rectangular pipe having overall dimentsions 63.50 milimetre X 38.10 milimetre X 1.02 milimetre at weight 0.547 kilogram per running metre and window frame bottom track section 61.85 milimetre X 31.75 milimetre X 1.20 milimetre at weight 0.695 kilogram per running metre. Top and side track section 61.85 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.659 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass with all required screws and nuts, excetra complete. - With colour anodising with box. (For 4th Floor) |
| 282 | Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of two tracks with rectangular pipe having overall dimentsions 63.50 milimetre X 38.10 milimetre X 1.02 milimetre at weight 0.547 kilogram per running metre and window frame bottom track section 61.85 milimetre X 31.75 milimetre X 1.20 milimetre at weight 0.695 kilogram per running metre. Top and side track section 61.85 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.659 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass with all required screws and nuts, excetra complete. - With colour anodising with box. (For 5th Floor) |
| 283 | Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of two tracks with rectangular pipe having overall dimentsions 63.50 milimetre X 38.10 milimetre X 1.02 milimetre at weight 0.547 kilogram per running metre and window frame bottom track section 61.85 milimetre X 31.75 milimetre X 1.20 milimetre at weight 0.695 kilogram per running metre. Top and side track section 61.85 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.659 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass with all required screws and nuts, excetra complete. - With colour anodising with box. (For 6th Floor) |
| 284 | Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of three tracks with rectangular pipe having overall dimentsions 95 milimetre X 38 milimetre X 0.90 milimetre at weight 0.637 kilogram per running metre and window frame bottom track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jali with all required screws and nuts excetra complete. - With colour anodising with box. (For Ground Floor) |
| 285 | Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of three tracks with rectangular pipe having overall dimentsions 95 milimetre X 38 milimetre X 0.90 milimetre at weight 0.637 kilogram per running metre and window frame bottom track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jali with all required screws and nuts excetra complete. - With colour anodising with box. (For First Floor) |
| 286 | Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of three tracks with rectangular pipe having overall dimentsions 95 milimetre X 38 milimetre X 0.90 milimetre at weight 0.637 kilogram per running metre and window frame bottom track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jali with all required screws and nuts excetra complete. - With colour anodising with box. (For 2nd Floor) |
| 287 | Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of three tracks with rectangular pipe having overall dimentsions 95 milimetre X 38 milimetre X 0.90 milimetre at weight 0.637 kilogram per running metre and window frame bottom track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jali with all required screws and nuts excetra complete. - With colour anodising with box. (For 3rd Floor) |
| 288 | Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of three tracks with rectangular pipe having overall dimentsions 95 milimetre X 38 milimetre X 0.90 milimetre at weight 0.637 kilogram per running metre and window frame bottom track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jali with all required screws and nuts excetra complete. - With colour anodising with box. (For 4th Floor) |
| 289 | Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of three tracks with rectangular pipe having overall dimentsions 95 milimetre X 38 milimetre X 0.90 milimetre at weight 0.637 kilogram per running metre and window frame bottom track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jali with all required screws and nuts excetra complete. - With colour anodising with box. (For 5th Floor) |
| 290 | Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of three tracks with rectangular pipe having overall dimentsions 95 milimetre X 38 milimetre X 0.90 milimetre at weight 0.637 kilogram per running metre and window frame bottom track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jali with all required screws and nuts excetra complete. - With colour anodising with box. (For 6th Floor) |
| 291 | Providing and fixing mild steel grill work for windows, ventilator, excetra 20 kilogram per square metre as per drawings including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting, excetra complete. (For Ground Floor) |
| 292 | Providing and fixing mild steel grill work for windows, ventilator, excetra 20 kilogram per square metre as per drawings including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting, excetra complete. (For First Floor) |
| 293 | Providing and fixing mild steel grill work for windows, ventilator, excetra 20 kilogram per square metre as per drawings including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting, excetra complete. (For 2nd Floor) |
| 294 | Providing and fixing mild steel grill work for windows, ventilator, excetra 20 kilogram per square metre as per drawings including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting, excetra complete. (For 3rd Floor) |
| 295 | Providing and fixing mild steel grill work for windows, ventilator, excetra 20 kilogram per square metre as per drawings including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting, excetra complete. (For 4th Floor) |
| 296 | Providing and fixing mild steel grill work for windows, ventilator, excetra 20 kilogram per square metre as per drawings including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting, excetra complete. (For 5th Floor) |
| 297 | Providing and fixing mild steel grill work for windows, ventilator, excetra 20 kilogram per square metre as per drawings including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting, excetra complete. (For 6th Floor) |
| 298 | Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 milimetre X 38 milimetre X 1.22 milimetre box type, 5 milimetre thick sheet glass louvers of approved quality, excetra complete. (For Ground Floor) |
| 299 | Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 milimetre X 38 milimetre X 1.22 milimetre box type, 5 milimetre thick sheet glass louvers of approved quality, excetra complete. (For First Floor) |
| 300 | Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 milimetre X 38 milimetre X 1.22 milimetre box type, 5 milimetre thick sheet glass louvers of approved quality, excetra complete. (For 2nd Floor) |
| 301 | Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 milimetre X 38 milimetre X 1.22 milimetre box type, 5 milimetre thick sheet glass louvers of approved quality, excetra complete. (For 3rd Floor) |
| 302 | Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 milimetre X 38 milimetre X 1.22 milimetre box type, 5 milimetre thick sheet glass louvers of approved quality, excetra complete. (For 4th Floor) |
| 303 | Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 milimetre X 38 milimetre X 1.22 milimetre box type, 5 milimetre thick sheet glass louvers of approved quality, excetra complete. (For 5th Floor) |
| 304 | Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 milimetre X 38 milimetre X 1.22 milimetre box type, 5 milimetre thick sheet glass louvers of approved quality, excetra complete. (For 6th Floor) |
| 305 | Providing and fixing mild steel grill railing weighing 15 kilogram per square metre with polyvinyl chloride handrail cover and newel post for staircases, including fabricating, fixtures, drilling holes in concrete / other surface, erecting the grill work, necessary welding, fixing by nuts and bolts, fixing polyvinyl chloride handrail cover, with one coat of anticorrosive paint and two coats of oil painting with approved colour and shade, remaking the damaged surface, cleaning, excetra complete. (For Ground Floor) |
| 306 | Providing and fixing mild steel grill railing weighing 15 kilogram per square metre with polyvinyl chloride handrail cover and newel post for staircases, including fabricating, fixtures, drilling holes in concrete / other surface, erecting the grill work, necessary welding, fixing by nuts and bolts, fixing polyvinyl chloride handrail cover, with one coat of anticorrosive paint and two coats of oil painting with approved colour and shade, remaking the damaged surface, cleaning, excetra complete. (For First Floor) |
| 307 | Providing and fixing mild steel grill railing weighing 15 kilogram per square metre with polyvinyl chloride handrail cover and newel post for staircases, including fabricating, fixtures, drilling holes in concrete / other surface, erecting the grill work, necessary welding, fixing by nuts and bolts, fixing polyvinyl chloride handrail cover, with one coat of anticorrosive paint and two coats of oil painting with approved colour and shade, remaking the damaged surface, cleaning, excetra complete. (For 2nd Floor) |
| 308 | Providing and fixing mild steel grill railing weighing 15 kilogram per square metre with polyvinyl chloride handrail cover and newel post for staircases, including fabricating, fixtures, drilling holes in concrete / other surface, erecting the grill work, necessary welding, fixing by nuts and bolts, fixing polyvinyl chloride handrail cover, with one coat of anticorrosive paint and two coats of oil painting with approved colour and shade, remaking the damaged surface, cleaning, excetra complete. (For 3rd Floor) |
| 309 | Providing and fixing mild steel grill railing weighing 15 kilogram per square metre with polyvinyl chloride handrail cover and newel post for staircases, including fabricating, fixtures, drilling holes in concrete / other surface, erecting the grill work, necessary welding, fixing by nuts and bolts, fixing polyvinyl chloride handrail cover, with one coat of anticorrosive paint and two coats of oil painting with approved colour and shade, remaking the damaged surface, cleaning, excetra complete. (For 4th Floor) |
| 310 | Providing and fixing mild steel grill railing weighing 15 kilogram per square metre with polyvinyl chloride handrail cover and newel post for staircases, including fabricating, fixtures, drilling holes in concrete / other surface, erecting the grill work, necessary welding, fixing by nuts and bolts, fixing polyvinyl chloride handrail cover, with one coat of anticorrosive paint and two coats of oil painting with approved colour and shade, remaking the damaged surface, cleaning, excetra complete. (For 5th Floor) |
| 311 | Providing and fixing mild steel grill railing weighing 15 kilogram per square metre with polyvinyl chloride handrail cover and newel post for staircases, including fabricating, fixtures, drilling holes in concrete / other surface, erecting the grill work, necessary welding, fixing by nuts and bolts, fixing polyvinyl chloride handrail cover, with one coat of anticorrosive paint and two coats of oil painting with approved colour and shade, remaking the damaged surface, cleaning, excetra complete. (For 6th Floor) |
| 312 | Providing and constructing brick masonry inspection chamber 60 centimetre X 45 centimetre X 90 centimetre including 1:4:8 cement concrete foundation, 1:2:4 cement concrete channels, half round glazed stoneware pipes, brick masonry, plastering from inside and airtight cast iron lid 75 kilogram with frame fixed in cement concrete, excetra complete. (using ARTIFICIAL SAND). |
| 313 | Providing and constructing brick masonry inspection chamber 90 centimetre X 45 centimetre X 90 centimetre including 1:4:8 cement concrete foundation, 1:2:4 cement concrete channels, half round glazed stoneware pipes, brick masonary, plastering from inside and cast iron lid cover 75 kilogram with frame fixed in cement concrete, excetra complete. (using ARTIFICIAL SAND). |
| 314 | Providing and laying concrete pipes of Indian Standard Non Pressure class of 300 milimetre diameter in proper line, level and slope including necessary collers, excavation, laying, fixing with collers in cement mortar 1:1 and refilling the trench excetra complete. |
| 315 | Providing and laying cement concrete pipe confirming to Indian Standard 458:2003 non pressure class-2 of 600 milimetre diameter in proper line, level and slope including providng and fixing collars in cement mortar 1:2 and curing, excetra complete. (using ARTIFICIAL SAND). |
| 316 | Providing and fixing on walls / celling / floor, 15 milimetre diameter chlorinated polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. (For Ground Floor) |
| 317 | Providing and fixing on walls / celling / floor, 20 milimetre diameter chlorinated poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. (For Ground Floor) |
| 318 | Providing and fixing on walls / celling / floor, 25 milimetre diameter chlorinated poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. (For Ground Floor) |
| 319 | Providing and fixing on walls / celling / floor, 32 milimetre diameter chlorinated poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. (For Ground Floor) |
| 320 | Providing and fixing on walls / celling / floor, 50 milimetre diameter chlorinated poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete. (For Ground Floor) |
| 321 | Providing and fixing White Glazed Earthenware Squatting plate (Ladies Urinal) with polyvinyl chloride flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 milimetre diameter P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connection up to the outside face of the wall. (For Ground Floor) |
| 322 | Providing and fixing white glazed earthenware full stall type urinal with poly vinyl chloride flushing cistern of 5 litres capacity with fitting inlet pipes and stop tap brackets for fixing the cistern 32 milimetre diameter poly vinyl chloride flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap soil pipe connection upto the outside face of the wall. (For Ground Floor) |
| 323 | Providing and fixing coloured glazed with bottle trap earthenware Wash Hand Basin of 55 centimetre X 40 centimetre size including cold water piller taps, brackets, rubber plugs and brass chain, stop tap, chromium plate bottle trap and necessary pipe connections including unplasticized polyvinyl chloride waste pipe and trap upto the outside face of the wall, making good the damaged surface, testing excetra complete. |
| 324 | Providing and fixing 10 centimetre cast iron nahani trap including cast iron grating, bend and piece of cast iron pipe upto the outside face of the wall complete. (For Ground Floor) |
| 325 | Providing and fixing 450 milimetre X 550 milimetre size superior type belgium mirror with 16 milimetre diameter nickel plated towel rod, excetra complete. (For Ground Floor) |
| 326 | Providing and fixing chromium plated towel rod 16 milimetre diameter and 75 centimetre in length including all accessories complete. (For Ground Floor) |
| 327 | Providing and fixing Orissa type colour glazed earthenware 625 milimetre X 450 milimetre water closet pan including trap, cast iron soil and vent pipe upto the out side face of wall including 100 milimetre diameter cast iron plug bend, 15 milimetre thick 10 litre polyvinyl chloride flushing cistern with all necessary pipe connection, excetra complete. (For Ground Floor) |
| 328 | Providing and fixing 75 milimetre diameter stabilliser pipe / polyvinyl chloride soil vent / waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps excetra complete. (For Ground Floor) |
| 329 | Providing and fixing 100 milimetre diameter stabilliser pipe / polyvinyl chloride soil vent / waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps, excetra complete. (For Ground Floor) |
| 330 | Providing and fixing on walls / celling / floor, 40 milimetre diameter chlorinated poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. (For Ground Floor) |
| 331 | Providing and laying in trenches 50 milimetre diameter chlorinated poly vinyl chloride pipe including necessary excavation, fittings, refilling trenches, excetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. |
| 332 | Providing and fixing chromium plated two way bib cock of approved make including necessary sockets / union nut, excetra complete. (For Ground Floor) |
| 333 | Providing and fixing chromium plated pillar cock long neck with aerator of approved make including necessary sockets / union nut, excetra complete. (For Ground Floor) |
| 334 | Providing and fixing oval type under counter wash hand basin of 16 inch X 22 inch size and of special colour shed having telephonic black / colour granite of 18 milimetre thick fixed on black kadapaa frame work, including cromium plated coupling, bottle-trap using approved make oval type wash basin as per detailed drawing or as directed by Engineer In-charge, excetra complete. (For Ground Floor) |
| 335 | Providing and fixing european type wall hung white water closet of approved make with push valve consealed type with cover plate 32 milimetre size of approved make including soil pipe, vent pipe upto outside face of wall, 100 milimetre diameter galvanised iron plug, bend, inlet pipe all fittings, cutting and making good walls, floors, excetra complete. (For Ground Floor) |
| 336 | Providing and fixing screw down for 20 milimetre diameter wheeled stop tap of brass including necessary sockets / union nut complete. (For Ground Floor) |
| 337 | Providing and fixing screw down for 25 milimetre diameter wheeled stop tap of brass including necessary sockets / union nut complete. (For Ground Floor) |
| 338 | Providing and fixing screw down 32 milimetre diameter wheeled stop tap of brass including necessary sockets / union nut complete. (For Ground Floor) |
| 339 | Providing and fixing screw down for 50 milimetre diameter wheeled stop tap of brass including necessary sockets / union nut complete. (For Ground Floor) |
| 340 | Providing and fixing poly vinyl chloride rain water pipes of 160 milimetre outer diameter and having wall thickness of 2.2 milimetre to 2.7 milimetre confirming to Indian Standard : 13592-1992 including proper rain water receiving recess with poly vinyl chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 milimetre to 40 milimetre from face of wall affixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on cement concrete or masonry blocks, including necessary scaffolding and maintenance for 3 years for any leakages or dislocations of pipes. All the poly vinyl chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge excetra complete. (For Ground Floor) |
| 341 | Providing and fixing stainless steel sink 600 milimetre X 510 milimetre X 200 milimetre of approved make including coupling, outlet pipe, elbo and other necessary fitting, finishing excetra complete. (For Ground Floor) |
| 342 | Providing and fixing of colour coated zincalume (R) AZ 150 (Minimum 150 grams per square metre total on each sides) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 milimetre base metal thickness (BMT) (0.5 milimetre TCT), Hi-strength steel with minium 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55 percent aluminium, 43.4 percent zinc, 1.6 percent silicon) with COLORBOND (R) steel quality super durable polyster paint coat (with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nominal 950-1050 milimetre effective cover width and nominal 25-30 milimetre deep ribs with subtle square fluting in the five pan at nominal 180-250 milimetre center to centre. The end rib shall be designed for anti capilary groove and return leg. The feed material should have coil manufacturer\"s product details marked at regular interval. Including fasteners with minium fatened with minium 25 um zinc-tin alloy coated, hex head, self-drilling screw, excetra complete. (Weight of profile 4.52 kilogram per square metre). (For Ground Floor) |
| 343 | Providing and fixing of colour coated zincalume (R) AZ 150 (Minimum 150 grams per square metre total on each sides) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 milimetre base metal thickness (BMT) (0.5 milimetre TCT), Hi-strength steel with minium 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55 percent aluminium, 43.4 percent zinc, 1.6 percent silicon) with COLORBOND (R) steel quality super durable polyster paint coat (with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nominal 950-1050 milimetre effective cover width and nominal 25-30 milimetre deep ribs with subtle square fluting in the five pan at nominal 180-250 milimetre center to centre. The end rib shall be designed for anti capilary groove and return leg. The feed material should have coil manufacturer\"s product details marked at regular interval. Including fasteners with minium fatened with minium 25 um zinc-tin alloy coated, hex head, self-drilling screw, excetra complete. (Weight of profile 4.52 kilogram per square metre). (For Terrace Floor) |
| 344 | Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates excetra as per detailed desings and drawings or as directed including cuting, fabricating, hoisting, erecting, fixing in position, making rivetted / bolted / welded connection and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade, excetra complete. (For Ground Floor) |
| 345 | Providing structural steel work of rectangular hollow steel section for steel trusses, other similar trussed items like purlin and members with all bracing, gusset plates, excetra as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade complete. (For Ground Floor) |
| 346 | Providing and applying french polishing to new wood work for required finish including kontting, preparing the surface, scaffolding, excetra complete as directed. (For Ground Floor) |
| 347 | Providing and applying french polishing to new wood work for required finish including kontting, preparing the surface, scaffolding, excetra complete as directed. (For First Floor) |
| 348 | Providing and applying french polishing to new wood work for required finish including kontting, preparing the surface, scaffolding, excetra complete as directed. (For 2nd Floor) |
| 349 | Providing and applying french polishing to new wood work for required finish including kontting, preparing the surface, scaffolding, excetra complete as directed. (For 3rd Floor) |
| 350 | Providing and applying french polishing to new wood work for required finish including kontting, preparing the surface, scaffolding, excetra complete as directed. (For 4th Floor) |
| 351 | Providing and applying french polishing to new wood work for required finish including kontting, preparing the surface, scaffolding, excetra complete as directed. (For 5th Floor) |
| 352 | Providing and applying french polishing to new wood work for required finish including kontting, preparing the surface, scaffolding, excetra complete as directed. (For 6th Floor) |
| 353 | Providing and applying malamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scrapping, applying french polishing, scaffolding, if required, excetra complete. (For Ground Floor) |
| 354 | Providing and applying malamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scrapping, applying french polishing, scaffolding, if required, excetra complete. (For First Floor) |
| 355 | Providing and applying malamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scrapping, applying french polishing, scaffolding, if required, excetra complete. (For 2nd Floor) |
| 356 | Providing and applying malamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scrapping, applying french polishing, scaffolding, if required, excetra complete. (For 3rd Floor) |
| 357 | Providing and applying malamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scrapping, applying french polishing, scaffolding, if required, excetra complete. (For 4th Floor) |
| 358 | Providing and applying malamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scrapping, applying french polishing, scaffolding, if required, excetra complete. (For 5th Floor) |
| 359 | Providing and applying malamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scrapping, applying french polishing, scaffolding, if required, excetra complete. (For 6th Floor) |
| 360 | Providing and applying two coats of synthetic enamel paint of approved colour to new / old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat), excetra complete. (For Ground Floor) |
| 361 | Providing and applying two coats of synthetic enamel paint of approved colour to new / old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat), excetra complete. (For First Floor) |
| 362 | Providing and applying two coats of synthetic enamel paint of approved colour to new / old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat), excetra complete. (For 2nd Floor) |
| 363 | Providing and applying two coats of synthetic enamel paint of approved colour to new / old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat), excetra complete. (For 3rd Floor) |
| 364 | Providing and applying two coats of synthetic enamel paint of approved colour to new / old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat), excetra complete. (For 4th Floor) |
| 365 | Providing and applying two coats of synthetic enamel paint of approved colour to new / old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat), excetra complete. (For 5th Floor) |
| 366 | Providing and applying two coats of synthetic enamel paint of approved colour to new / old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat), excetra complete. (For 6th Floor) |
| 367 | Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. reinforced cement concrete pardi/ Wall and all type of Interior, Exterior Compound wall and Gate excetra of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, glass fibre reinforced concrete admixtures, Colour pigments, Fiber up to thick of 230 milimetre / 25 milimetre including scaffolding,fixing of screw, excetra (As directed by Engineer in Charge) |
| 368 | Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. reinforced cement concrete pardi/ Wall and all type of Interior, Exterior Compound wall and Gate excetra of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, glass fibre reinforced concrete admixtures, Colour pigments, Fiber up to thick of 230 milimetre / 25 milimetre including scaffolding,fixing of screw, excetra (As directed by Engineer in Charge) |
| 369 | Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. reinforced cement concrete pardi/ Wall and all type of Interior, Exterior Compound wall and Gate excetra of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, glass fibre reinforced concrete admixtures, Colour pigments, Fiber up to thick of 230 milimetre / 25 milimetre including scaffolding,fixing of screw, excetra (As directed by Engineer in Charge) |
| 370 | Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. reinforced cement concrete pardi/ Wall and all type of Interior, Exterior Compound wall and Gate excetra of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, glass fibre reinforced concrete admixtures, Colour pigments, Fiber up to thick of 230 milimetre / 25 milimetre including scaffolding,fixing of screw, excetra (As directed by Engineer in Charge) |
| 371 | Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. reinforced cement concrete pardi/ Wall and all type of Interior, Exterior Compound wall and Gate excetra of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, glass fibre reinforced concrete admixtures, Colour pigments, Fiber up to thick of 230 milimetre / 25 milimetre including scaffolding,fixing of screw, excetra (As directed by Engineer in Charge) |
| 372 | Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. reinforced cement concrete pardi/ Wall and all type of Interior, Exterior Compound wall and Gate excetra of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, glass fibre reinforced concrete admixtures, Colour pigments, Fiber up to thick of 230 milimetre / 25 milimetre including scaffolding,fixing of screw, excetra (As directed by Engineer in Charge) |
| 373 | Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. reinforced cement concrete pardi/ Wall and all type of Interior, Exterior Compound wall and Gate excetra of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, glass fibre reinforced concrete admixtures, Colour pigments, Fiber up to thick of 230 milimetre / 25 milimetre including scaffolding,fixing of screw, excetra (As directed by Engineer in Charge) |
| 374 | Providing and fixing 900 milimetre high, stainless steel 304 grade stainless steel railing with 40 milimetre diameter and 1.5 milimetre thick at top, 40 milimetre diameter and 1.5 milimetre thick verticle supports spaced at 1.5 metre center to center and 8 milimetre thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe, excetra complete. (For Ground Floor) |
| 375 | Providing and fixing 900 milimetre high, stainless steel 304 grade stainless steel railing with 40 milimetre diameter and 1.5 milimetre thick at top, 40 milimetre diameter and 1.5 milimetre thick verticle supports spaced at 1.5 metre center to center and 8 milimetre thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe, excetra complete. (For First Floor) |
| 376 | Providing and fixing 900 milimetre high, stainless steel 304 grade stainless steel railing with 40 milimetre diameter and 1.5 milimetre thick at top, 40 milimetre diameter and 1.5 milimetre thick verticle supports spaced at 1.5 metre center to center and 8 milimetre thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe, excetra complete. (For 2nd Floor) |
| 377 | Providing and fixing 900 milimetre high, stainless steel 304 grade stainless steel railing with 40 milimetre diameter and 1.5 milimetre thick at top, 40 milimetre diameter and 1.5 milimetre thick verticle supports spaced at 1.5 metre center to center and 8 milimetre thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe, excetra complete. (For 3rd Floor) |
| 378 | Providing and fixing 900 milimetre high, stainless steel 304 grade stainless steel railing with 40 milimetre diameter and 1.5 milimetre thick at top, 40 milimetre diameter and 1.5 milimetre thick verticle supports spaced at 1.5 metre center to center and 8 milimetre thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe, excetra complete. (For 4th Floor) |
| 379 | Providing and fixing 900 milimetre high, stainless steel 304 grade stainless steel railing with 40 milimetre diameter and 1.5 milimetre thick at top, 40 milimetre diameter and 1.5 milimetre thick verticle supports spaced at 1.5 metre center to center and 8 milimetre thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe, excetra complete. (For 5th Floor) |
| 380 | Providing and fixing 900 milimetre high, stainless steel 304 grade stainless steel railing with 40 milimetre diameter and 1.5 milimetre thick at top, 40 milimetre diameter and 1.5 milimetre thick verticle supports spaced at 1.5 metre center to center and 8 milimetre thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe, excetra complete. (For 6th Floor) |
| 381 | Providing and fixing 20 milimetre to 25 milimetre thick rough shahabad box type waterproofing for basement or underground floor on a base of cement concrete 1:3:6, including sub-base of 2.50 centimetre thick cement mortar 1:3 with conceal, setcrete (RMW), Algeeproof or other alike water proofing liquids, raking of joints upto 35 milimetre depth, filling the joints with 6 milimetre size crushed metal, hand grouting with cement slurry, curing and cleaning, with seven years gaurantee on court fee stamp paper of Rs. 100/- with ponding test excetra complete. (excluding cement concrete 1:3:6 base concrete). |
| 382 | Providing and fixing 20 milimetre to 25 milimetre thick rough shahabad box type waterproofing treatment to vertical outside faces of reinforced cement concrete walls of basement or underground floor including filling the gap of 25 milimetre between rough shahabad and reinforced cement concrete walls with cement grout mixed with water proofing liquid Algeeproof or alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width of 30 milimetre to 35 milimetre and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with cement concrete 1:2:4 mixed with water proofing liquid, curing, with seven years gaurantee on court fee stamp paper of Rs. 100/- with ponding test, excetra complete. (excluding cement concrete 1:3:6 base concrete). |
| 383 | Providing and laying vitrified matt finish tiles of having size 590 milimetre to 605 milimetre X to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For First Floor) (using ARTIFICIAL SAND). |
| 384 | Providing and laying vitrified matt finish tiles of having size 590 milimetre to 605 milimetre X to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For 2nd Floor) (using ARTIFICIAL SAND). |
| 385 | Providing and laying vitrified matt finish tiles of having size 590 milimetre to 605 milimetre X to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For 3rd Floor) (using ARTIFICIAL SAND). |
| 386 | Providing and laying vitrified matt finish tiles of having size 590 milimetre to 605 milimetre X to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For 4th Floor) (using ARTIFICIAL SAND). |
| 387 | Providing and laying vitrified matt finish tiles of having size 590 milimetre to 605 milimetre X to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For 5th Floor) (using ARTIFICIAL SAND). |
| 388 | Providing and laying vitrified matt finish tiles of having size 590 milimetre to 605 milimetre X to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For 6th Floor) (using ARTIFICIAL SAND). |
| 389 | Providing and laying vitrified matt finish tiles having size 590 milimetre to 605 milimetre X to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for dado and skirtingin required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For First Floor) (using ARTIFICIAL SAND). |
| 390 | Providing and laying vitrified matt finish tiles having size 590 milimetre to 605 milimetre X to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for dado and skirtingin required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For 2nd Floor) (using ARTIFICIAL SAND). |
| 391 | Providing and laying vitrified matt finish tiles having size 590 milimetre to 605 milimetre X to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for dado and skirtingin required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For 3rd Floor) (using ARTIFICIAL SAND). |
| 392 | Providing and laying vitrified matt finish tiles having size 590 milimetre to 605 milimetre X to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for dado and skirtingin required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For 4th Floor) (using ARTIFICIAL SAND). |
| 393 | Providing and laying vitrified matt finish tiles having size 590 milimetre to 605 milimetre X to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for dado and skirtingin required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For 5th Floor) (using ARTIFICIAL SAND). |
| 394 | Providing and laying vitrified matt finish tiles having size 590 milimetre to 605 milimetre X to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for dado and skirtingin required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For 6th Floor) (using ARTIFICIAL SAND). |
| 395 | Providing and fixing machine cut mirror polished 18 milimetre to 20 milimetre thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone partition with rounding / moulding the edegs, excetra complete. - Both side polish (For First Floor) (using ARTIFICIAL SAND). |
| 396 | Providing and fixing machine cut mirror polished 18 milimetre to 20 milimetre thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone partition with rounding / moulding the edegs, excetra complete. - Both side polish (For 2nd Floor) (using ARTIFICIAL SAND). |
| 397 | Providing and fixing machine cut mirror polished 18 milimetre to 20 milimetre thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone partition with rounding / moulding the edegs, excetra complete. - Both side polish (For 3rd Floor) (using ARTIFICIAL SAND). |
| 398 | Providing and fixing machine cut mirror polished 18 milimetre to 20 milimetre thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone partition with rounding / moulding the edegs, excetra complete. - Both side polish (For 4th Floor) (using ARTIFICIAL SAND). |
| 399 | Providing and fixing machine cut mirror polished 18 milimetre to 20 milimetre thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone partition with rounding / moulding the edegs, excetra complete. - Both side polish (For 5th Floor) (using ARTIFICIAL SAND). |
| 400 | Providing and fixing machine cut mirror polished 18 milimetre to 20 milimetre thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone partition with rounding / moulding the edegs, excetra complete. - Both side polish (For 6th Floor) (using ARTIFICIAL SAND). |
| 401 | Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25 milimetre to 450 milimetre section as per Indian Standard : 4923 YST 310 grade produced from iron ore and blast furnace route, excetra as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and painting complete. (For First Floor) |
| 402 | Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25 milimetre to 450 milimetre section as per Indian Standard : 4923 YST 310 grade produced from iron ore and blast furnace route, excetra as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and painting complete. (For 2nd Floor) |
| 403 | Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25 milimetre to 450 milimetre section as per Indian Standard : 4923 YST 310 grade produced from iron ore and blast furnace route, excetra as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and painting complete. (For 3rd Floor) |
| 404 | Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25 milimetre to 450 milimetre section as per Indian Standard : 4923 YST 310 grade produced from iron ore and blast furnace route, excetra as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and painting complete. (For 4th Floor) |
| 405 | Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25 milimetre to 450 milimetre section as per Indian Standard : 4923 YST 310 grade produced from iron ore and blast furnace route, excetra as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and painting complete. (For 5th Floor) |
| 406 | Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25 milimetre to 450 milimetre section as per Indian Standard : 4923 YST 310 grade produced from iron ore and blast furnace route, excetra as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and painting complete. (For 6th Floor) |
| 407 | Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in cement mortar 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with cement mortar 1:3 admixed with approved water proofing compound and finally top finishing with average 20 milimetre thick layers of same mortar added with jute fiber at one kilogram per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 milimetre X 300 milimetre, making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test, excetra complete. (For Terrace Floor) (using ARTIFICIAL SAND). |
| 408 | Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in cement mortar 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with cement mortar 1:3 admixed with approved water proofing compound and finally top finishing with average 20 milimetre thick layers of same mortar added with jute fiber at one kilogram per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 milimetre X 300 milimetre, making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). |
| 409 | Providing and fabricting structural steel work in rolled sections like joists, channels, angles, tees, excetra as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted / welded connections without connecting plates, braces, excetra and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade, excetra complete. (For Terrace Floor) |
| 410 | Construction of dry lean cement concrete sub-base over a prepared sub-grade with coarse and fine aggregate (V.S.I. grade finely washed crushed sand) conforming to Indian Standard : 383, the size of coarse aggregate not exceeding 25 milimetre, cement content not to be less than 150 kilogram per cubic metre, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant / weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor / by suitable means as approved by Engineer in-charge, compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required, excetra complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. |
| 411 | Providing earth work in embankment with approved materials obtained from other sources upto lead of 50 metres including all lifts, laying in layers of 20 centimetre to 30 centimetre thickness, breaking clods, dressing to the required lines, curves, grade and section, watering and compaction with vibratory roller with V-Sat attachment to achive not less than 97 percent of standard proctor density, excetra complete. (Material obtained from Other sources) |
| 412 | Supplying hard murum / kankar at the road site, including conveying and stacking, excetra complete. |
| 413 | Spreading hard murum / soft murrum / gravel or kankar for side width, excetra complete. |
| 414 | Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering, excetra complete. |
| 415 | Providing and laying in situ cement concrete M-30 with tremix treatment for 200 milimetre thickness for concrete road including laying plastic sheet of 125 micron thickness with groove cutting of 4 milimetre wide and 20 milimetre deep with necessary refilling with bitumen (excluding reinforcement) with coarse and fine aggregate (V.S.I. grade finely washed crushed sand) excetra complete. |
| 416 | Providing and fixing heavy duty inter locking concrete rubber mould glossy paving blocks of 60 milimetre thickness of having a strength of 400 kilogram per square centimetre of approved quality and shape on a bed of crushed sand of 25 milimetre to 30 milimetre thick including striking joints and cleaning excetra complete.(using 100 per cent crushed sand), excetra complete. |
| 417 | Providing and casting in situ or precast tapering reinforced cement concrete M-20 Barrier type kerb with gutter (as per Indian Road Congress : 86-1983) embedded 125 milimetre below ground level over M-10 plain cement concrete finished neatly with cement mortar 1:2, setting the same in cement mortar 1:2, including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specified and directed by Engineer in-charge. Using concrete batching and mixing plant. |
| 418 | Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fiber glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 square metre per kilogram with two coats Using approved chemicals for masonry and concrete surface by brush, covering seven years gaurantee on stamp paper, excetra complete. (For Ground Floor) |
| 419 | Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance and thermal emittance tested as per ASTM) C 1549 and ASTM C 1371 respectively, VOC less than 10 cc/gm. The coating thickness and the methodology of application shall strctly as per manufacturer\"s specifitions and as approved by engineer in charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus, etc, washing with water all complete.The contractor shall give guarantee for the performance of SRI and also the durabitity of coating, all complete as per direction of Engineer - in- incharge. (For Ground Floor) |
| 420 | Providing, constructing 2.0 metre deep shallow depth percolation pit comprising of 1.0 metre diameter pre-cast reinforced cement concrete rings, 300 milimetre thick side filling around outside of reinforced cement concrete rings (annular space) with 40 milimetre size boulders including filling of percolation pit up to 0.5 metre depth (from bottom up) with 25-75 milimetre clean washed gravels followed by 0.5 metre depth of 10-25 milimetre of clean washed stones followed by 0.5 metre of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed excetra) including netlon mesh between each gravel / fine aggregate (natural sand/crushed sand VSI grade finely washed, excetra) media layer including covering with reinforced cement concrete slab, manhole frame and cover, polyvinyl chloride rungs, excetra including arrangement for inlet and outlet pipe, excavation and backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge |
| 421 | Providing and constructing recharge pit of 2.0 metre deep and 1.0 metre diameter of pre-cast reinforced cement concrete rings with 6.5 Inch diameter X 25 metre deep borewell at the floor of recharge pit including installation of combination of solid / perforated polyvinyl chloride casing pipe wrapped around with netlon mesh including 300 milimetre thick sidefilling around outside of reinforced cement concrete rings (annular space) with 40 milimetre size boulders including filling of recharge pit up to 0.5 metre depth with 25-75 milimetre clean washed gravels from bottom up followed by 0.5 metre depth of 10-25 milimetre of clean washed stones followed by 0.5 metre of washed river fine aggregate (natural sand / crushed sand VSI grade finely washed excetra) including netlon mesh between each gravel / fine aggregate (natural sand / crushed sand VSI grade finely washed, excetra) media layer including covering with reinforced cement concrete slab, manhole frame and cover, polyvinyl chloride rungs, polyvinyl chloride end-caps, fittings, excetra including arrangement for inlet and outlet pipe excavation and backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge. |
| 422 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized polyvinyl chloride medium well-casing pipe of 150 milimetre diameter, conforming to Indian Standard : 12818, including required hire and labour charges, fittings and accessories, excetra all complete, for all depths, as per the direction of Engineer in charge. |
| 423 | Supplying, filling, spreading and leveling stone boulders of size range 5 centimetre to 20 centimetre in recharge pit, in the required thickness, for all leads and lifts, all complete as per the direction of Engineer-in-charge. |
| 424 | Supplying, filling, spreading and leveling gravels of size range 5 milimetre to 10 milimetre, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads and lifts, all complete as per direction of Engineer-incharge. |
| 425 | Providing and fixing 90 centimetre X 60 centimetre granite name plate engraving 10 centimetre height letter, figures including painting the letters / figures with approved colour and shade complete. |
| 426 | Providing and laying polished handcut Kotah stone flooring 25 milimetre to 30 milimetre thick and 45 centimetre to 55 centimetre wide in plain / diamond pattern on a bed of 1:6 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). |
| 427 | Providing and fixing board displaying information, such as \"Name of work, Tender cost, Name of Contractor, Work completion and liability period etc\", having rectangular shape of 1.20 metre X 0.90 metre size made out 18 gauge (1.25 milimetre) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols excetra with approved colour shade paint complete, on M.S.angle of size 35 milimetre X 35 milimetre X 3 milimetre frame with properly cross braced mild steel angles of size 35 milimetre X 35 milimetre X 3 milimetre duly painted including two mild steel angle iron posts of size 65 milimetre X 65 milimetre X 6 milimetre, 3.65 metre long painted with alternate black and white bands of 25 centimetre width including all fixtures excetraand fixing the boards in 1:4:8 concrete block of size 60 centimetre X 60 centimetre X 75 centimetre including, excavation, refilling, transportation, and labour etc complete. Spec. number As directed by Engineer in Charge |
| 428 | Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 429 | Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 430 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 431 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 432 | Supplying and erecting Green colour earthwith 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW (with Note 3) |
| 433 | Supplying and erecting Green colour earthwith 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 434 | Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 435 | Supplying and erectingGreen colour earth with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(with note 3) |
| 436 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 437 | Supplying and erecting Green colour earth with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW (with note 3) |
| 438 | Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 439 | Supplying and erecting ISI mark modular type switch 16A duly erected on provided plate and box with wiring connections complete. |
| 440 | Supplying and erecting modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete. |
| 441 | Supplying and erecting ISI mark modular type 3 pin 6A multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 442 | Supplying and erecting modular type 3 pin 6 / 16Amultisocket with safety shutterISI mark approved make duly erected on provided plate and box with wiring connections complete. |
| 443 | Supplying and erecting ISI mark modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. |
| 444 | Supplying and erecting ISI mark modular type blanking plate one module, duly erected on provided plate & box. |
| 445 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 446 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 447 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 448 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 449 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 450 | Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW |
| 451 | Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+2E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW(With note 3)(Two Way Control) |
| 452 | Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW |
| 453 | Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/HW |
| 454 | Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW |
| 455 | Secondary point wiring for additional light/ bell point, concealed type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW |
| 456 | Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/CW |
| 457 | Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 770 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 458 | Supplying and erecting LED square / circular Max. 14 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 459 | Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 460 | Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty |
| 461 | Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 462 | Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete. |
| 463 | Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF |
| 464 | Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab. |
| 465 | Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. |
| 466 | Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 40 litres per hour and storage capacity 80 litres with partially stainless steel body As per specification no. APWCR/ WC |
| 467 | Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8W capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system. |
| 468 | Supplying, erecting, testing and commissioning of 3kVA capacity online pure sine wave with backup time of 0.30 hrs. PWM & IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS |
| 469 | Supplying, erecting, testing and commissioning of 6kVA capacity online pure sine wave with backup time of 0.30 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS |
| 470 | Supplying, erecting, testing and commissioning of 10kVA capacity online pure sine wave, with backup time of 0.5 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input & 3 phase output complete with all protections as per specification no. AP-UPS |
| 471 | Supplying and erecting 12V/17Ah -18Ah SMF battery with battery terminal wire, duly charged with 12 months warranty complete (For 3KVA UPS) |
| 472 | Supplying and erecting 12V/26Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete (For 6KVA UPS) |
| 473 | Supplying and erecting 12V/42Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete (For 10KVA UPS) |
| 474 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 475 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 476 | Supplying, erecting & marking SPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 477 | Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 478 | Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 479 | Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 480 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 481 | Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 482 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 483 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 484 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 485 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flushmounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB |
| 486 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, withdoor, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 487 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 488 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, oniron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 |
| 489 | Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB (With Note 1) |
| 490 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 491 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 492 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 493 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 494 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 495 | Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 300 mm width & 20 mm height complete with necessary hardware. |
| 496 | Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 500 mm width & 20 mm height complete with necessary hardware. |
| 497 | Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP |
| 498 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. |
| 499 | Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete. |
| 500 | Providing and back filling ground enhancing compound 25 kg bag complete. |
| 501 | Supplying and erecting aluminium raceway 100 X 40 X 2 mm on floor/wall/ceiling using C type clamps for fixing the raceways properly. Further raceways shall be earthed with each other / junction box with suitable size cu pvc coat wire & lugs to form a continues earth connection. The edges of raceways shall be smoothed at the cut section by file to avoid any damage to the wires while laying in raceway to the satisfaction of the engineer in charge |
| 502 | Supplying and erecting aluminium raceway 150 X 50 X 2 mm on floor/wall/ceiling using C type clamps for fixing the raceways properly. Further raceways shall be earthed with each other / junction box with suitable size cu pvc coat wire & lugs to form a continues earth connection. The edges of raceways shall be smoothed at the cut section by file to avoid any damage to the wires while laying in raceway to the satisfaction of the engineer in charge |
| 503 | Design, fabrication, assembling, supply,installation, testing and commissioning of cubicle type LT panels as per IEC 61439 -Part 1 & 2 suitable for 415 V 3 phase ,4 wire 50 Hz AC supply system fabricated in compartmentised design from CRCA sheet steel of 2 mm thick for frame work IP 52 and covers,3 mm thick for gland plates l/c cleaning and finishing complete 9 tank process for powder coating in approved shade RAL 7032, extendable type TPN aluminium alloy busbars of high conductivity,DMC/SMC busbar supports, with bottom base channel of MS section not less than 75mm X 50 mm x 5 mm thick, entire panel shall have a common copper earthbar of required size at the rear with 2 nos earth studs,solid connection from main busbar to switchgears with require size of aluminium busbar & control wiring with 2.5sqmm FRLS insulated copper conductor cable,cable alleys,cable gland plates i/c accessrories as per specification and providing switchgears, metering instruments etc. for follwing panels. Rate shall inclusive of all required all accessories circuting indication lamps, MFM & all other as shown in SLD. (Panel RA Seperataly Attached)MAIN LT PANEL - 1 INCOMER :400 A FP MCCB Feeder - 1 Nos.400 A FP MCCB Feeder - 1 Nos.400 A MCCB SPREADER LINK - 1 Nos.CT 400A/5A 10 VACl 0.5 - 1 Nos.Indicating lamp 240V AC R/Y - 2 Nos.Indicating lamp 240V AC B -1 Nos.Indicating lamp 240V AC On/Off/trip - 3 Nos.Indicating lamp 240V AC On/Off/trip - 3 Nos.Multifunction Meter - 1 Nos.2A SP MCB - 6 Nos.2A SP MCB - 6 Nos.2A SP MCB - 6 Nos.Bus Bar Support OUTGOING :100 A FP MCCB Feeder - 7 Nos.100 A MCCB SPREADER LINK - 7 Nos.Indicating Lamp 240 V ACOn/Off/trip - 21 Nos 63 A FP MCCB Feeder - 3 Nos.63 A MCCB SPREADER LINK - 3 Nos.Indicating Lamp 240 V AC On/Off/trip - 9 Nos.160 A FP MCCB Feeder - 4 Nos.160 A MCCB SPREADER LINK - 4 Nos.Indicating Lamp 240 V ACOn/Off/trip - 12 Nos.Aluminum Bus Bar Size with 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm.40 mm X 10 mm40 mm X 10 mm40 mm X 5 mm |
| 504 | Providing & erecting hot dipped galvanised ladder type cable traymanufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 100 mm height comprising all required standard accessories. |
| 505 | Providing & erecting hot dipped galvanised ladder type cable traymanufactured from 16 SWG (1.6 mm thick) GI sheet of 500 mm width & 100 mm height comprising all required standard accessories. |
| 506 | Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV (17 Pole x 4 mtr =68) |
| 507 | Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 508 | Supplying and erecting Gate/garden light fitting with 200mm dia. glass bowl suitable for upto 12W LED Lamp on provided pipe as per specification No. FGODF/GLT |
| 509 | Supplying & erecting 10-12W, 230V integral type LED Lamp suitable for B-22 / E-27 base. |
| 510 | Supplying & erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation. |
| 511 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 512 | Supplying, erecting, testing & commissioning 11kV, 630A, 21kA/3sec, 1 way Indoor/outdoor, extensible motorised SCADA compatible RMU, internal arc tested consisting of 1 no. feeder with 1 LBS compliant to IEC 62271 -100, 200 and 102, as per specification no. SW-HTS/RMU SCADA |
| 513 | Supplying, erecting, testing and commissioning 11KV HT metering cubical (compact / vertical type) approved by MSEDCL / licensee fabricated with 2 mm (14 SWG) M.S. sheets with supporting angle, painted with powder coating / epoxy paint of required shade, copper bus bar size 25 x 6 mm, heavy duty mechanical lock, with counter meter for measuring no of times the opening of meter door, top side cover (CT, PT cover) interlock with meter door, epoxy casted 3 nos. CT having required ratio between 50/5A to 200/5A, VA 10 or 15, Class 0.2S, epoxy casted 3 nos. PT having ratio 11000/V3/110/V3 VA 50, Class 0.2 suitable for provided trivector meter, and provision for incoming and outgoing cables complete duly tested by licensee with necessary test certificates and erected on provided plinth/ cc foundation. |
| 514 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 515 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 516 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 517 | Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT |
| 518 | Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable 3 x up to 95 sq. mm. with necessary material as per specification No. CB-JT/HT |
| 519 | Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 520 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 521 | Providing & erecting 4 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL |
| 522 | Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT |
| 523 | Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT |
| 524 | Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP |
| 525 | Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP |
| 526 | Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP |
| 527 | Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EAEP. |
| 528 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. |
| 529 | Supplying, installing, testing & commissioning 3 phase,11/0.433 kV, 50 Hz., 250 kVA, Mineral oil immersed and naturally cooled indoor type, Copper wound Non-sealed transformer delta/star connected with additional neutral brought out on load side, temperature rise should not Exceed 45℃ by thermometer in oil and 50℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5%, having 7 number of tap positions ,withstandard accessories complete with test certificate with losses below 980 Watts at 50% load, 2930 Watts at 100% load as per IS:1180 (part 1) : 2014, with necessary permissions of Electrical Inspector, as per specification no SS- TRNSL. |
| 530 | Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete of medium duty (100 Kilogram). |
| 531 | Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation, fixing provided nut bolts with the help of template, duly plastered as per design complete (for 3 to 5m octagonal / conical GI pole). |
| 532 | Makingtransformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick M- 10 PCC at the bottom and top and 250 mm. thick, burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. External surface duly plastered by 12 mm thick including watering etc complete. |
| 533 | Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. (as per note 2 - For drain piping refer rates of PVC pipes from chapter no. 1) |
| 534 | Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 5.00 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC |
| 535 | Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor. room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 5.0 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP-AC/WAC |
| 536 | Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 2.1TR to 2.3TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC |
| 537 | Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete. |
| 538 | Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete. |
| 539 | Carrying out core cutting of size 3\" to 5\" dia x 15\" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. (with note 2) |
| 540 | Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 12 mm for solar water heater/AC system. |
| 541 | Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 16 mm for solar water heater/AC system |
| 542 | Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. |
| 543 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 544 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 545 | Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 546 | Supplying and erecting modular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 547 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 548 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 549 | Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW |
| 550 | Supplying & erecting 10 pair, 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW |
| 551 | Supplying & erecting 20 pair, 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW |
| 552 | Supplying & erecting 50 pair, 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW |
| 553 | Supplying and erecting 15m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. |
| 554 | Supplying & erecting HDMI Extender Over RJ45 Ethernet Cable Cat 6, 60m/200ft complete |
| 555 | Supplying, erecting & commissioning MDF Box 150x150 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW |
| 556 | Supplying, erecting & commissioning 10 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW |
| 557 | Supplying, erecting & commissioning 20 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW |
| 558 | Supplying, erecting & commissioning 30 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW |
| 559 | Supplying, erecting & commissioning 40 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW |
| 560 | Supplying, Erecting and Commissioning of10 pair module for connection & disconnection of telephone cable as per specification no. WG-TW |
| 561 | Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of 6 x 32 extensions suitable upto 96 extensions complete.(Note: 1) 4nos. Add Rs. 38159.00 for additional 16 extension card for digital (hybrid) type EPABX) |
| 562 | Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of 6 x 32 extensions suitable upto 96 extensions complete.(Note : 2) 1nos Add Rs. 19032.00 for additional 8 extension card for digital (hybrid) type EPABX) |
| 563 | Supplying, installing, testing & commissioning push button telephone instrument desk top unit as per specification complete |
| 564 | Supplying, installing, testing & commissioning push button telephone instrument desk top/wall mount with caller ID & Speaker unit as per specification complete. |
| 565 | Supplying, installing, testing & commissioning IP telephone instrument as per specification complete. |
| 566 | Supplying and installing cat-6 LSZH cable suitable for networking as per specification no. WG-COC/NC |
| 567 | Supplying and installing armoured single mode optical fibre cable with 6 fiber, core dia 50/125μm (OS1/OS2) 10/40 GBPS speed in provided underground HDPE pipe complete |
| 568 | Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC |
| 569 | Supplying and fixing IP66 enclosure for fibre splicing complete. |
| 570 | Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS |
| 571 | Supplying, fixing, and configuring 24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WGNWC/GBS |
| 572 | Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. |
| 573 | Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO |
| 574 | Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP |
| 575 | Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK |
| 576 | Supplying & erecting of High definition 4/5 Megapixel IP IR Bullet Camera with following features Image Sensor : minimum 1/2.8\" Progressive Scan CMOS,Video Resolution : minimum 2592 x 1520 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream,Frame rate : minimum 25 fps at all resolutions,WDR : minimum 120 dB Wide Dynamic Range,ONVIF profile conformant,minimum IR distance : 50m,Lens Type : 2.8/4/6 mm Lens, fixed focal,Field of View : 2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129° 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65° Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m.Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°.Power Supply : Support 12VDC & PoE,IP67, IK10 - Vandal Resistant.Built in micro SD/SDHC/SDXC card slot of minimum 128 GB,Built in microphone.minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out× 1.Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance.Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection.Operating temperature ( -30 to 60° C ) .Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed,FTP disabled.Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol.RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified. duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM. |
| 577 | Supplying & erecting of High definition 4/5 Megapixel IP IR Dome Camera with following features Image Sensor : minimum 1/2.8\" Progressive Scan CMOS,Video Resolution : minimum 2592 x 1520 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream,Frame rate : minimum 25 fps at all resolutions,WDR : minimum 120 dB Wide Dynamic Range,ONVIF profile conformant,minimum IR distance : 50m,Lens Type : 2.8/4/6 mm Lens, fixed focal,Field of View : 2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129° 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65° Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m.Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°.Power Supply : Support 12VDC & PoE,IP67, IK10 - Vandal Resistant.Built in micro SD/SDHC/SDXC card slot of minimum 128 GB,Built in microphone.minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out× 1.Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance.Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection.Operating temperature ( -30 to 60° C ) .Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, |
| 578 | Supplying, installing, testing & commissioning of 64 Ch Network Video Recorder (NVR), suitable connect Min. 64 IP Cameras, up to 5 Megapixel Resolution, with HDMI 1/VGA 1 and HDMI 2/VGA 2 outputs provided, Atleast one HDMI output of 4K resolution, atleast one VGA output with output up to 1920 × 1080, Support H.265 or higher, H.264, MJPEG, Supports Redundant Dual Power, Incoming Bandwidth 320 Mbps with minimum 8 SATA Hard Disks, ANRTe chnology, 8 SATA interfaces for 8 HDDs and capacity of each HDD up to 8TB, minimum 02 USB port, Alarm I/O 16/4, RJ-45 10/100/ 1000 Mbps selfadaptive Ethernet interface, support multi brand network Cameras, ONVIF conformance, Multiple network monitoring: Web viewer .support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP™, HTTPS. RoHS, UL, CE, FCC certified. duly erected in provided U Rack with wiring connections, tagging and programming etc. |
| 579 | Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S, maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64, Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected in position in provided NVR |
| 580 | Supplying & erecting 55\" professional LED display with 1920 *1080 ( Full HD) Display, suitable for 32/64 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In,Built-in speakers maximum 10 W,Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON |
| 581 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 582 | Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP |
| 583 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. |
| 584 | Supply installation Testing & Commissioning of ‘Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of 180 KVA 415 volts at 1500 RPM 0.8 lagging power factor at 415 V suitable for 50 Hz 3 phase system & for 0.85 Load Factor including testing at factory and site with fuel load for test and other necessary arrangements Complete as per PWD specifications should have QR code which should contain drawing test report OEM manual Geo- Tag of manufacturing location rating plate as per relevant IS Code etc. and consisting of the followings (A) Diesel Engine Tourbocharged Diesel engine 4 stroke water cooled multi cylinder dynamically balanced fly wheel electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C 50% RH & at 1000 Meter MSL fuel consumption 30.90 Ltr/hr 75% loading capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor Dry type Air filter with service indicator first filling of engine fuel (after commissioning) lubricating OilCoolant and other consumables complete with all the required accessories the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514 BS 649 IS 10000 IS 10002 IS 13018 and as per PWD specifications.(B) Engine mounted Instrument Panel fitted with andhaving digital display for following (i) Start-stop switch with key (ii) Water temperature indication (iii) Lubrication oil pressure indication (iv) Lubrication oil temperature indication (v) Battery charging indication and Voltage indication (vi) RPM indication (vii) Over speed indication (viii) Low lubricantion Oil trip indication (ix) Engine Running Hours indication (x) Fuel Level (C) Alternator Synchronous alternator rated of 180 KVA 415 volts at 1500 RPM 3 phase 50 Hz AC supply with 0.8 lagging power factor at 40 Degree C 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23 brushless continuous duty dynamically balanced rotor capable of taking 10% over loading for one hour after 12 hours of continuous operation self cooled self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS 4722/BS 2613 suitable for tropical conditions and with class- H insulation. (D) Base Frame & Foundation Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.(E) FUEL TANK Daily service fuel tank of suitable liters capacity as per PWD Specifications fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves level indications & accessories as required as per specifications.(F) Exhaust System Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor. (G) Starting System 12V/24V DC starting system comprising of starter motors voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set. (H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine &alternator extraction discharging hot air in to the atmosphere and the temperature rise inside the enclosure noise level outside enclosure. The acoustic enclosure shall restrict the sound level upto 75 dB should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and provided with first filling of oil and diesel not less than 300 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG.[Non CSR] |
| 585 | Supplying, erecting, testing and commissioning of microprocessor based AMFpanel suitable for diesel generating set of above 140 kVA up to 180 kVAcapacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. [with note 1] |
| 586 | Excavating soft murum / soft soil road by chiselling for preparing pit for polesstay or earth plates or for laying cables, pipes & clearing the site by removingdebris & making the site good complete. (250KVA = 4.65m X 1.95m) |
| 587 | Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). (250KVA = 4.65m X 1.95m X 0.3m ) |
| 588 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 589 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete |
| 590 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module duly erected. |
| 591 | Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW (with Note 3)(Two way point) |
| 592 | Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. |
| 593 | Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 594 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 595 | Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 596 | Supplying and erecting single pole and neutral distribution board (SPNDB),with 2 ways for incoming and 2 ways (2 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 597 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. |
| 598 | Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 599 | Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 600 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 601 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 602 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cmcomplete with all materials, testing & recording the results as per specification no.EA-EP |
| 603 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. |
| 604 | SITC of Electric Traction Passenger Lift with · Rated capacity :- 8 Passenger/544Kg · Floors :- G+6 floor (7 Stops/7 Landings) · Travel :- 3 to 29 mtrs· Location of Lift Machine:- MR · Rated speed :- 1.0 mps VS · Car/Landing door clear opening of 800 mm wide x 2000 mm high· Clear Car size of 1300 mm wide x 1100 mm deep x 2250mm high · Lift shaft available having clear size of 1900 mm wide x 1900 mm deep, 1900 mm Pit depth, 4200 mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. ARD complete with necessary SMF VRLA batteries. Fireman controller having fireman switch at fire Landing. CCTV surveillance system comprises of 2 nos minimum 2.0 MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. Lift Machine ofGearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. Other mechanical parts such as \"T\" section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. Minor civil work such as alteration work if any necessary for erection of landing door frames and it\"s accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & \"License to Work the Lift\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.A2) For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid (non-cladded) landing door [Two panel], this includes all necessary accessories like LOP\"s with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, traveling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete.(Single floor add on.)B1) For Full Collective control system, add as below. For Lift travelling above First floor & up to Sixth floor ((Main Lift Rate + Add on upto sixth floor+ Collective control )=1087600+(137031*5)+27340) |
| 605 | SITC of Electric Traction Passenger Lift with · Rated capacity :- 16 Passenger/1088Kg · Floors :- G+6 floor (7 Stops/7 Landings) · Travel :- 3 to 29 mtrs · Location of Lift Machine:- MR/MRL · Rated speed :- 1.0mps VS· Car/Landing door clear opening of 1100 mm wide x 2000 mm high· Clear Car size of 1600mm wide x 1600mm deep x 2250mm high · Lift shaft available having clear size of 2300mm wide x 2300 deep,2300 mm Pit depth, 4200mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor.LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. ARD complete with necessary SMF VRLA batteries. Fireman controller having fireman switch at fire Landing. CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 20” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft wallscomplete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.Other mechanical parts such as \"T\" section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.Minor civil work such as alteration work if any necessary for erection of landing door frames and it\"s accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. General: - Job includes entire procedure of obtaining all necessary erection permissions & \"License to Work the Lift\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.A5) For Lift having 1100mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOP\"s with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete.B1) For Full Collective control system, add as below. For Lift travelling above First floor & up to Sixth floor ((Main Lift Rate + Add on upto sixth floor+ Collective control )=1669432+(150580*5)+27340) |
| 606 | Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 2280 to 2850 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 55kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP |
| 607 | Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 9.3 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP |
| 608 | Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP |
| 609 | Supplying, erecting, testing & commissioning of fire pump control panel (FCP) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories, wiring & cabling along with allied accessories with following incoming and outgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specifications the capacity of electric motor driven pump are as follows a. Main fire pump(MFP) having capacity of 22kW 1no (1 working) b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby, alternate run per start in auto mode) comprises of the following features & switchgears: 1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating. 2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU\"s, starters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connections, mounted on required no of epoxy or porcelain support insulators of suitable ratings etc. 3. Individual pump TPN SFU having rotary handle with HRC fuses of suitable rating.4. Digital voltmeter & ammeter & RYB indicating lamps & push buttons & SPP, O/L & phase reversal protection with emergency stop switch. 5. TPN SPD 100kA Type 1 +2 tested. 6. Required pressure transducer with pressure indication on panel with cabling required for monitoring & automatic operation of fire pumps. 7. System controller to control operation of main electric fire pump, jockey (pressurization) pumps in sequence with interlocking for operation of pumps as per specification with automatic/manual operation with selector switch & alternate run of standby Pumps consisting of relays, timers. sensors, annunciation window for fault indication, complete as per specification. 8.Suitable capacity electric motor starters for all individual pumps with necessary push buttons & indications. 9. Siren of required capacity to be activated when main pump starts & allied accessories as per requirements of local CFO or as directed by engineer in charge. 10. Danger board as per IS. 11. Spare HRC fuses minimum 2nos of each individual rating with required bakelite fuse holder for main & jockey fire pumps MFP=(1working), JP = (1working+1standby, alternate run per start in auto mode) complete panel, as per specification no. FF-MFP/ECP For addition of capacity of main electric motor driven fire pump MFP (1 working) for hydrant system is more than 22kW, add as follows in the basic cost of Item no 13-5-1 towards increased capacity switchgears and motor starters for main & jockey pumps along with necessary accessories for main & jockey fire pumps MFP=(1working), JP = (1working + 1standby, alternate run per start in auto mode)For main electric motor driven fire hydrant system pump of 55kW capacity & relevant capacity jockey pump add Rs…. (69004/-)For addition of fire sprinkler system to basic fire hydrant system control panel(FCP) which includes one main electric motor driven fire pump MFP (1working) having __kW capacity & relevant capacity jockey pumps, add as follows in the basic cost of Item no 13-5-1 towards increased capacity switchgears busbar and additional motor starters for main & jockey pumps along with necessary accessories with software & hardware for main & jockey fire pumps additional Sprinkler system FP=(1working)@22kW, JP = (1working+1standby, alternate run per start in auto mode) @relevant capacity For main electric motor driven fire sprinkler system pump of 55kW capacity (1Working) & relevant capacity jockey pumps (1working+1standby, alternate run per start in auto mode, add Rs…. (239209/-)For addition of standby main diesel engine driven fire pump (1 standby), add as follows in the basic cost of Item no 13-5-1 towards required 12/24 v battery charger and diesel engine starter along with necessary accessories, indicators etc. with necessary interlocking and updation of control logic with interlocking for operation of pumps MFP for main (1working+1standby mode) & jockey fire pumps (1working+1standby, alternate run per start in auto mode) , add Rs....... The control for diesel engine comprises of automatic/manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low Lub. oil pressure, high water temp and engine on indication battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC voltmeter, and 0-20 A DC ammeter with all standard relays and accessories required for automatic operation of diesel engine with interlocking for operation of main fire pumps. (68381/-) |
| 610 | Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP |
| 611 | Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP |
| 612 | Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings complete as per specification no. FF-PP |
| 613 | Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP |
| 614 | Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP |
| 615 | Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP |
| 616 | Supplying and erecting G.I. pipe ‘C’ class ERW 200 mm dia with necessary fittings complete as per specification no. FF-PP |
| 617 | Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system. |
| 618 | Supplying and erecting 100 mm dia cast iron foot valve ball type/flaptype with strainer for negative suction complete asper specification no. FF-VL/FV |
| 619 | Supplying and erecting 150 mm dia cast iron foot valve ball type/flaptype with strainer for negative suction complete asper specification no. FF-VL/FV |
| 620 | Supplying and erecting 100 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS |
| 621 | Supplying and erecting 50 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 622 | Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 623 | Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 624 | Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 625 | Supplying and erecting 200 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 626 | Supplying and erecting 75/80 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 627 | Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 628 | Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 629 | Supplying and erecting 200 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 630 | Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV |
| 631 | Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV |
| 632 | Supplying and installing one piece moulded HDPE/ fibre water tank for negative suction only, having capacity 1000 litres fitted with necessary accessories complete as per specification no. FF-FFA/PT |
| 633 | Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV |
| 634 | Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL |
| 635 | Supplying and erecting 19 mm dia high pressure poly propylene hose pipe complete asper specification no. FF-FFA/HOP |
| 636 | Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FFFFA/ NZ |
| 637 | Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC |
| 638 | Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FF FA/FMC |
| 639 | Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT |
| 640 | Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV |
| 641 | Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG |
| 642 | Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS |
| 643 | Supplying and erecting brass orifice plate having 6 mm. thickness, 140 mm outer dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP |
| 644 | Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8\"x6\") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) |
| 645 | Supplying, installing, testing and commissioning remote response indicators suitable to operate on 5- 28 V dc supply having FR Polymer ABS Housing complete as per specification no. FF-FAAS/RRI |
| 646 | Supplying, installing, testing and commissioning FRLS armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU |
| 647 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 4 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ- ACwith inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, ,IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP |
| 648 | Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than 175 x 275 x 65 mmconforming to EN 54 or UL approved with 3 years equipment replacement warranty FF-AFAS/RP |
| 649 | Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FF AFAS/SD . |
| 650 | Supplying, installing, testing and commissioning of intelligent addressable thermal/ heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from- 20°C to 38 °C for fixed-heat and rate-of-rise type detectors whereas 0°C to 90°C for high heat type detectors, in built isolation mode, suitable for industrial/ kitchen/ boiler room etc. with 3 years equipment replacement warranty, IS : 2175-1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD. |
| 651 | Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with \"Break Glass\" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP. |
| 652 | Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM |
| 653 | Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM |
| 654 | Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM |
| 655 | Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH. |
| 656 | Supplying, erecting, testing and commissioning 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR |
| 657 | Supplying, erecting, testing and commissioning 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC |
| 658 | Supplying, erecting, testing and commissioning stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity, impedance level limit 300 ohms and 50- 16000 Hz suitable to operate in-10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector, stereo jack complete as per specification no. FF-PA/MIC |
| 659 | Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC |
| 660 | Supplying, erecting, testing and commissioning of 1.5 sq. mm speaker wire complete. |
| 661 | Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15 mm(½\") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF SPR. |
| 662 | Supplying, erecting, testing and commissioning vane type water flow detector 75/80 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes. |
| 663 | Supplying and erecting fire resistant mortar (20 kg) with fire resistance class S90 as per National Electrical Code (NEC) SP30-2011 suitable to seal the openings of all kinds of cables, pipes and cable support system in steel, aluminium and plastic profiles ( except hollow core conductors). The residual openings shall be closed with filler, as per specification no FF-FRM. |
| 664 | Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. |
| 665 | Supplying and erecting 25mm dia. corrugated flexible polypropylene conduit |
| 666 | Supplying and erecting HMS PVC conduit FRLS grade 25mm dia. with PVC accessories on wall /ceiling as per specification No: WG-MA/CON. |
| 667 | Supplying and fixing 6U wall mount rack (Dimension-DxWxH– 500x600x367 mm) as per specification No. WG-NAS/RAK |
| 668 | Supplying and erecting 12V/7Ah-7.5Ah SMF battery with battery terminal wire, duly charged with 12 months warranty complete |
| 669 | Carrying out core cutting of size 3\" to 5\" dia x 15\" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. |
| 670 | Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. |
| 671 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 672 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 673 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core 400 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 674 | Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware. |
| 675 | Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware. |
| 676 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP |
| 677 | Supplying and erecting aluminium strip of high purity required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint with joints required as per specification no EA-EP. |
| 678 | Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete. |
| 679 | Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps). |
| 680 | Supplying and erecting non return valve 50 mm dia in position made of gun metal complete. |
| 681 | Providing Round bottom fire bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete. |
| 682 | Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete. |
| 683 | Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall. |
| 684 | SITC of self Luminous Exit Sign in accordance with BS5499as per sample approved by incharge (FIRE EXIT 300mm X 100mm) |
| 685 | Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPTmale thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets,center bracket, stockbar of following sizes complete as required. (1500 mm long) |
| 686 | Supply & Fixing of approved Type rosette plates for spriklers below false celling area The Rosette Shall be fabricated by M.S Plate of 2 mm Thick and the finish shall be powder coated. |
| 687 | Supply installation testing jointing and commissioning of support comprising of threaded suspention rod with bullet fastener, threaded at both ends. Flexible sleeve with supporting arrangement for spriklers piping of various diameters, complete in all respect |
| 688 | Supply, installation, testing and commissioning of 150 mm dia. Installation Wet Alarm Valve with Water Motor Gong, Pressure Gauges, Test Lines with Ball Valves with necessary GI (H) piping with threaded fittings of required sizes complete. |
| 689 | Supplying and erecting G.I. pipe ‘C’ class ERW 32 mm dia with necessary fittings complete as per specification no. FF-PP |
| 690 | Supplying and erecting G.I. pipe ‘C’ class ERW 40 mm dia with necessary fittings complete as per specification no. FF-PP |
| 691 | Providing coating of bitumen paint & 4mm thick wrapping for underground 100 mm ring main of fire fighting system. |