Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | V.C. RESIDENCE BUILDING WORKEarth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating nos deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m |
| 3 | Diluting and injecting chemical emulsion for PRE- CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 4 | Supplying and filling in plinth with sand under floors,including watering, ramming, consolidating and dressing complete. |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - Allwork up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone- III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 6 | Providing centering & shuttering including strutting, propping etc. & removal of form including all materials, labour and T & P etc. required for proper completion of work all completeFoundation, Footing, base of columns and plinth beam in any shape and size upto plinth level. |
| 7 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 8 | Lintels, beams, plinth beams, girders, bressumers andcantilevers |
| 9 | Suspended floors, roofs, landings, balconies and accessplatform |
| 10 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cumAll works up to Plinth level. |
| 11 | All works AbovePlinth level & upto Floor V Level |
| 12 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D ormore. |
| 13 | Brick work with common burnt clay modular bricks of classdesignation 7.5 in foundation and plinth in: Cement Mortar 1:4(1 cement : 4 coarse sand) |
| 14 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 15 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1cement :3 coarse sand) |
| 16 | 15 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) |
| 17 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) |
| 18 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) |
| 19 | Making grooves 10 to 12mmwidex 8mm deep in plaster of the wallor in ceiling vertically or horizontally as required. |
| 20 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid forseparately).Second class teak wood |
| 21 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 22 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). |
| 23 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 24 | French spirit polishing :Two or more coats on new worksincluding a coat of wood filler |
| 25 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface evenand smooth complete. |
| 26 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnablepriming coat with cement primer |
| 27 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @2.20kg/10 sqm |
| 28 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smoothcomplete. |
| 29 | Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. (Make Hilti/ Fisher/ Helifix)Frame anchor HRD-C 10x140 |
| 30 | Providing and fixing aluminium sliding door bolts, ISI marked anodised anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm |
| 31 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, withnecessary screws etc. complete : 200x10 mm |
| 32 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, withnecessary screws etc. complete : 125 mm |
| 33 | Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement..(40mm thick with20 mm nominal aggregate). |
| 34 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. IN : toilet Block |
| 35 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shadesexcept burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 36 | Providing and laying Italian marble of 18 mm thickness (polished finish) over prepared screed/substrate with polymer-modified thin-set adhesive, jointing with matching grout, polishing, sealing, and finishing, complete as per manufacturer’s specifications and Architect’s direction. |
| 37 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete Double charged Vitrified Tile Polish finish Size 1200x600 mm |
| 38 | Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red Area of slab over 0.50 sqm |
| 39 | Stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) Make Stonex or Equivellent |
| 40 | 25 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with Second classteak wood |
| 41 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 42 | Providingandlayingintegralcementbasedwaterproofing treatmentincludingpreparationofsurfaceasrequiredfor treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using2.75kg/sqmofcementadmixedwithwaterproofing compound conforming to IS. 2645 and approved by Engineer- in-chargeovertheRCCslabincludingadjoiningwallsupto300 mm height including cleaning the surface before treatment.b)Layingbrickbatswithmortarusingbroken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar1:5(1cement:5coarsesand)admixedwithwater proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar ofmix1:5(1cement:5coarsesand)admixedwithwater proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to requiredslope and treating similarly the adjoining walls upto 300 mm heightincludingroundingofjunctionsofwallsandslabsc) Aftertwodaysofpropercuringapplyingasecondcoatof cement slurry using 2.75 kg/ sqm of cement admixed jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed withwaterproofingcompoundconformingtoIS :2645and |
| 43 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm nos having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats ofprimer suitable for board, all as per manufacturer\"s specification and also |
| 44 | Providing & Fixing of (Armstrong / USG Boral / Hunterdouglous) Soft Fibre Acoustical Suspended Ceiling System with Optra Beveled Tegular Edge Tiles With Armstrong Suprafine 15mm Exposed Grid.The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9 - 1.0, Colour Black, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600x600x15mm, suitable for Green Building application, with Recycled content of 66% GW & 74% RW.The tile shall be laid on Armstrong Suprafine 32 with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 32mm& pull out strength of 100Kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system of Armstrong make. INSTALLATION: To comprise main runner spaced at 1200mm securely fixed to the structural soffit using Armstrong suspension system (specifications below) at 1200mm maximum. The First/Last Armstrong suspension system at the end of nos main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm to form 1200 x 600 mm module.Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be Armstrong wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum. Installation to be carried out by Armstrong Trained Installation team & Installation should be carried out as per Armstrong recommendedprocedure. ARMSTRONG SUSPENSION SYSTEM accessories |
| 45 | Providing and installing a fully modular, high-end kitchen setup including base units, wall units, tall units, and integrated accessories. The carcass shall be made of 18 mm BWP (Boiling Water Proof) grade plywood (IS 710), laminated internally with 1 mm white laminate and all edges sealed with matching PVC edge banding. Shutters shall be finished in high-gloss PU paint / acrylic laminate / veneer with PUpolish or lacquered glass, mounted on soft-close hinges (Hettich/Blum), with drawers fitted with soft-close tandem channels. Lift-up systems shall be provided in overhead cabinets where applicable. Handle-less profile or designer handles shall be used as per the approved design. The countertop shall be made of premium 18–20 mm thick Quartz / Granite or large format porcelain slab with matching backsplash up to the overhead cabinets. A double bowl under-mount sink in stainless steel (Franke/Nirali/Blanco) with a designer pull-out faucet shall be provided. The under-sink cabinet shall have a waterproof base and built-in cleaning tray. Accessories include modular cutlery trays, bottle pull-outs, corner carousels or magic corners, pull-out pantry units, and dual-bin waste segregation systems. |
| 46 | Supplying, installing, testing, and commissioning of kitchen chimney of wall-mounted / island type as per layout, with suction capacity not less than [900–1200 m³/hr], auto-clean technology, stainless steel or glass finish, baffle filters / filterless, complete with ducting (PVC/Aluminium flexible), clamps, wall sleeve, exhaust cap, electrical connection, and all accessories for proper functioning, including making cut-outs in masonry/plywood for ducts and making good the same, all complete as per approved make, technical specifications, and instructions of the Engineer-in-Charge |
| 47 | Providing and fixing mica laminate finish (decorative high-pressure laminate) of approved make, shade, and thickness (typically 1.0 mm) on furniture surfaces / wall paneling / partitions / doors, etc., using approved synthetic resin adhesive (Fevicol SH or equivalent) over prepared surface (e.g., BWP grade plywood, MDF, blockboard), including edge finishing, trimming, cleaning, and all tools, adhesives, materials, labour and incidentals, complete in all respects as per drawings and instructions of the Engineer-in-ChargeMake Greenply/ sylivan/Austin) |
| 48 | Providing and fixing Vineer On Flush Doors As per Architect approval Make Greenply/ sylivan/Austin) |
| 49 | High-Pressure Laminate (HPL) exterior façade includes supply and installation of weather-resistant HPL panels (typically 6-8mm thick) fixed on an aluminum or galvanized steel subframe. Panels are UV- stabilized, fire-rated, and come in various finishes. The scope covers mechanical fasteners, EPDM gaskets, sealants, and necessary support brackets, ensuring proper ventilation and thermal movement allowance. Rates generally range from ₹750 to ₹1,400 per sq. meter, including materials and labor, with a recommended 5-10% wastage. Final costs depend on panel brand, façade area, and site conditions. Make Fundermax/ New Mica /Skydecore |
| 50 | Providing 7 Fixing Material: Aluminum Composite Panel (typically 4mm thickness)Finish: PVDF or Polyester coated, weather and UV resistantSub-frame: Aluminum or GI framing with brackets and fastenersTypical Rate: ₹900 to ₹1,600 per sqm (including supply, fabrication, and installation)Includes: ACP panels, substructure, fixings, sealants, and labor Note: Rates vary depending on brand, panel thickness, coating type, and site conditions Make Fundermax/ New Mica /Skydecore |
| 51 | Providing and fixing exterior-grade thin brick veneer tiles (approx. 2¼\" x 7⅝\", thickness ½\"–¾\"), of approved make, size, color, and texture, in [running bond / herringbone / stack bond] pattern, laid over prepared substrate with polymer-modified thin-set mortar or Type N/S cement mortar, including surface preparation, corner units, control joints, pointing, cleaning, and necessary scaffolding, all complete as per drawings, specifications, and instructions of the Engineer-in-Charge |
| 52 | Providing & fixingsystem Profile Aniodised Aluminium Window all complte as per direction of enginner in charge Fixed part (Tostom , Schuco) |
| 53 | Providing & fixingsystem Profile Aniodised Aluminium Window all complte as per direction of enginner in charge Casement window with top pin(Tostom , Schuco) |
| 54 | Providing & fixingsystem Profile Aniodised Aluminium Window all complte as per direction of enginner in charge Slider 3T 3P Triple track (Tostom , Schuco) |
| 55 | ELECTRICALINSTALLATIONSWIRING POINTS AND SUBMAINSPoint wiring in PVC ConduitWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copperconductorsinglecorecableinsurface/ recessedmediumclassPVCconduit,with modularswitch,modularplate,suitableGIbox and earthing the point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable etc.Group C |
| 56 | Power plug wiring in PVC conduit (2 x 4sqmm.) :-Wiringforlight/powerplugwith2X4sq.mm FRLS PVCinsulatedcopperconductorsinglecorecablein surface/ recessed medium class PVC conduit alongwith1No.4sq.mmFRLSPVCinsulated copper conductor single core cable for loopearthing as required. |
| 57 | Circuit / Sub main wiring in PVC conduit :-Wiringfor circuit/submain wiringalongwith earth wire with the following sizes of FRLS PVC insulatedcopperconductor,singlecorecablein surface/recessedmediumclass PVCconduit asrequired.2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. Earth wire |
| 58 | 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire |
| 59 | 4 x 6 sq.mm. + 2 x 6 sq.mm. Earth wire |
| 60 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 61 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 62 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessedconduit as required20 mm. |
| 63 | 25 mm. |
| 64 | 32 mm. |
| 65 | S/F light plug point modular type accessories :-SupplyingandfixingsuitablesizeGIboxwith modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modularsocketoutletand5/6Amodularswitch,connections etc. as required |
| 66 | S/F power plug point modular type accessories :-SupplyingandfixingsuitablesizeGIboxwith modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 67 | S/F modular type electronic fan regulator :-Supplyingandfixingtwomodulesteppedtype electronicfanregulatorontheexistingmodular plateswitchboxincludingconnectionsbutexcluding modular plate etc. as required. |
| 68 | S/F modular type blanking plate :-Supplyingandfixingmodularblankingplateon the existing modular plate & switch box excludingmodular plate as required. |
| 69 | TELEPHONE, TELEVISION AND DATA NETWORKTELEPHONE WIRING IN EXISTING CONDUIT :-Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmoredtelephonecableintheexisting surface/ recessed steel/ PVC conduit as required2 Pair |
| 70 | S/F MODULAR BOXES, BASE & COVER PLATE :-Supplyingandfixing followingsize /modules, GI boxalongwithmodularbase&coverplatefor modular switches inrecessetc as required 1 or 2 Module (75 mm x 75 mm) |
| 71 | S/F MODULAR TYPE SWITCH / SOCKET :-Supplyingandfixingfollowingmodularswitch/ socket on the existing modular plate & switch box including connections but excluding modular plateetc as required Telephone Socket outlet |
| 72 | DISTRIBUTIONBOARDS,MCB\"s, MCCB\"sANDSFU\"sSupplying and fixing following way, horizontal type threepoleandneutral,sheetsteel,MCB distribution board, 415V,onsurface/recess, complete with tinned copper bus bar, neutral bus bar,earthbar,dinbar,interconnections,powder paintedincludingearthingetc.asrequired.(Butwithout MCB/RCCB/Isolator)4 way (4 + 12), Double door, horizontal type |
| 73 | 6 way (4 + 18), Double door, horizontal type |
| 74 | Supplying andfixing 5A to32 A rating, 240/415 V,10kA,\"C\"curve,miniaturecircuitbreaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as requiredsingle pole |
| 75 | Supplyingandfixingfollowingrating,fourpole, 415 V, isolator in the existing MCB DB complete with connections,testing andcommissioning etc.as required40 amps. |
| 76 | 63 amps. |
| 77 | Supplying& fixing singlepole, blankingplate in the existing MCBDBcomplete etc. as required. |
| 78 | Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, TPMCB, in sheet steel enclosure,onsurfaceorinrecess,withchained metalcoverforthesocketoutletandcomplete with connections,testing andcommissioning etc. as required. |
| 79 | G.I.EARTHINGEarthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with coverplate having lockingarrangementandwateringpipeof2.7 metrelongetc.withcharcoal/cokeandsaltasrequired. |
| 80 | Supplying and laying 25 mm X 5 mm G.I strip at0.50 metre below ground as strip earth electrode, includingconnection/terminatingwithG.I.nut, bolt,spring,washeretc.asrequired.(Jointing shallbedonebyoverlappingandwith2setsofG.I. nut bolt & spring washer spaced at 50mm) |
| 81 | Providingandfixing25mmX 5mmG.I.strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 82 | ERECTIONOFLIGHTINGFIXTURESANDFANSInstallation,testingandcommissioningofceiling fan,includingwiringthedownrodsofstandard length(upto30cm)with1.5sq.mmFRLS PVC insulated,copperconductor,singlecorecable, includingprovidingandfixingphenoliclaminated sheet cover on the fan box etc. as required. |
| 83 | Installation of exhaust fan in the existing opening, includingmakinggoodthedamage,connection, testing, commissioning etc. as required. Upto 450mm sweep |
| 84 | SupplyandfixingofLEDTubeLightwithbatten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect.CAT- AAA |
| 85 | Supplyandfixingof12Wattto15Wattindoor RecessmountingLEDSquareFittingfor Armstrong Ceiling having Powder coated die cast aluminium housing with extended heat sink, diffuserofPolycarbonatemeterialanddriversetcomplete in all respect. CAT- AAA |
| 86 | Supplyandfixingofrecess/Surface/Pendent mounting round 6 Watt 8 Watt LED Down Lighter havingPowdercoateddiecastaluminium housingwithheatsink,diffuser/Reflectorand driver set complete in all respect. CAT- AAA |
| 87 | Supply and fixing of recess mounting round 15 to 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflectoranddriversetcompleteinallrespect. CAT- AAA |
| 88 | Supply and fixing of sqaure Light 40-60Watt LED DownLight(600x600)mmhavingPowder coated die cast aluminium housing with heat sink, diffuser/Reflectoranddriversetcompleteinallrespect. |
| 89 | Providing & Fixing of modular plate type white RJ 45CAT6Dataoutlet/informationoutletsETL verifiedtomeetorexceedTIA/EIAcategory6 requirements,universalwiringlabelpermittingto eitherT568AorT568B,ULlisted, forcomputer networking completeinallrespectwithcover plate, grid plate, screws, MS box, etc withconnections as required.1 Nos RJ 45 Data Outlet |
| 90 | Supply,Installation,TestingandCommissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan withBrushLessDirectCurrent(BLDC)Motor, class of insulation: B, 3 Nosblades,30cmlongdownrod,2Noscanopies, shacklekit,safetyrope,copperwinding,Power Factor not less than 0.9, Service Value (CMM/W) minimum6.85,Airdeliveryminimum215CMM, 350 RPM (tolerance as per IS : 374-2019),THDlessthan10%,remoteorelectronic regulator unit for speed control and all remaining accessoriesincludingsafetypin,nutbolts, washers, temperaturerise=75degreeC(max.),insulationresistance more than 2 mega ohm, suitable for 230 V, 50 Hz, singlephaseACSupply,earthingetc.complete as required.1200 mm sweep |
| 91 | Supply of AC230/250 volts, 50 HZ exhaust fansincludingproviding nuts,bolts,mountingframe and other accessories etc.Complete300 mm sweep 900 rpm |
| 92 | Supply,installation, testing and commissioning ofMainDistribution Boardsuitableforupto 125ampFPMCCBincomerandsingle/three phaseoutgoingMCB\"s,IP43protection,double metal door, factory fabricated, wall mounting type insurface/recess,powdercoated,415V/200 amp copper Bus Bar, earth and neutral bar, removableglandplates,cableglandsincluding connection with outgoing feeders completeinall respect. DB\"s shall be original factory fabricated of approvedmake.Theratesshallbeexcludingall incoming and outgoing circuit breakers.8 Way TPN |
| 93 | ProvidingandfixingoffollowingratingFourpole MCCB\"sattheincomerofMain/subdistribution boardswith connectionsetc.completeasrequired.100 Amp FP MCCB(16 KA) |
| 94 | Supplying, fixing, connecting, testing and commissioning of followingrating, ISI marked (IS 8828) 240 / 415 volts, 10 KA, Miniature Circuit Breaker(MCB) ofsingle/double/three/ four polesintheexistingMCBDBorinexistingMS enclosure complete in all respects.25 Amp. TP MCB |
| 95 | 40 Amp.TP MCB |
| 96 | Supply, installation, testing and commissioning of electrical pane, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection. Thepanelsheetstructureshallundergo seventank pre-treatmentprocess beforepainting. The sheet steel shall be all of 2.2mm thick CRCA sheet.All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers.The panel height shall not exceed 2200mmandthemaximumoperatingheightforany switchgear shall not be more than 1700mm.The panel shallbeprovidedwithminimum75mmbasechannel frame fabricated from ISMC sections.All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable. Continuousearthbusshallrunalroundthe panel with earthingstudsprovidedatminimum2places. The control wiring shall be carried out with minimum1.5/2.5 sqmm copper wires and adequatenumberofNO/NC,potentialfreecontacts incorporated for remote operation of the starters. Propersizedcableterminationglandplatesshallbe provided oncable alleys and knockouts for same shall beprovidedduringfabricationstage itself. The panel shallbeprovidedwithathermostaticallycontrolled heatingarrangement(200W)totakecareofhigh humidity conditions.A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel.Panel shall be so designed at to have minimum 20% spare feeders/space.Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement. All cable terminations shall be from top. The complete panel shall be fuse less type,for control circuits 2A/6A MCB\"s to be used. Allbusbarsshallbeofaluminium,electrolyticgrade only. Maximumdesigndensityshallnotexceed1 Amps/Sqmm. Allbusbarsshallbeinsulatedwith colouredheatshrinkablePVCsleeved. Allbusbar supports shall be non hygroscopic DMC/SMC supports. Thepanelshallbemanufacturedinconformanceto requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. The minimum clearances between bus bars shall be as follows : Phase to phase - minimum 20mm Phase to neutral-minimum 15mm Main L.T. Panel -G.F. Incoming : One (1) No 300Amp. 4 pole 1 NO. Metering : One(1)No.(0-500V)96x96Sqmmvoltmeterwith control fuse & selector switch. One(1)No.(0-300A)96x96SqmmCToperated Ammeter with selector switch, CTs etc. One (1) Set of Phase Indication Lamp. Bus Bar : One (1) No. 300 Amp. TPN aluminimum bus bar of suitable length. Outgoing : Phase indication lamps on nos outgoing to be provided. 100 Amps TPN-1No. OR outgoing as per site requirment |
| 97 | ProvidingandLayingunplastisizedrigidPVCpipe conformingtoIS:13592typeAincludingjointing, cutting andmakinggoodthewalls&floorsasper requirement. 150mm |
| 98 | PLUMBING WORKSProvidingandfixingwhitevitreouschina extended wall mounting water closet of size 780x370x690mmofapprovedshape includingproviding&fixingwhitevitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4litre/8litres),includingseatcover,and cisternfittings,nuts,boltsandgasketetccomplete. |
| 99 | Providing & fixing white vitreous china wash basin with C.I. brackets painted white,15mmC.P.brasspillartaps,C.P.brass chainwithrubberplug,32mmC.P.brass waste of standerd pattern including cutting & making good the walls wherever required.a)White Vitreous China Wash basin size 630x450mmwithapairof15mmC.P.brass pillar taps |
| 100 | ProvidingandfixingP.V.C.wastepipefor sinkorwashbasinincludingP.V.C.wastefittings complete.Semi rigid pipe32 mm dia |
| 101 | Providingandfixing600x450mmbevelled edgemirrorofsuperiorglass(ofapproved quality) complete with 6mm thick hard board groundfixedtowoodencleatswithC.P.brass screws and washers complete. |
| 102 | RangeofTwohalfstallurinalswith5litre PV.C. automatic flushing cistern. |
| 103 | Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitionsbycuttingachaseofappropriate widthwithchasecutterandembeddingthe stone in the chase withepoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size)asperdirectionofEngineer-in-chargeand finished smooth.Granite Stone of approved shade |
| 104 | CP Brass fittingsProviding and fixing unplasticised PVC connection pipe with brass unions45 cm length15 mm nominal bore |
| 105 | Providingandfixing C.P.brass bibcock of approved quality conforming to IS:8931a) 15 mm nominal bore |
| 106 | ProvidingandfixingC.P.brasslongbody bibcockofapprovedquality conformingto IS standards andweighing not less than 690gms.a) 15 mm nominal bore |
| 107 | ProvidingandfixingC.P.brassanglevalve for basin mixer and gyser points of approved quality conforming to IS:8931a) 15 mm nominal bore |
| 108 | Providing and fixing unplasticised-PVC pipe clipsofapproveddesigntounplasticised- PVC pipes by means of 50x50x50 mm hard woodplugs,screwedwithMSscrewsof required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarsesand)andmakinggoodthewall etc. complete.110mm |
| 109 | 90mm |
| 110 | Providingandlayingcementconcrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size)aroundP.V.CSoilandwastepipeincludingbed concrete as per standard design(embedded in the flooring / ground)110 mm dia |
| 111 | 90 mm dia |
| 112 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conformingtoIS:13592TypeAincluding jointingwithsealringconformingtoIS: 5382leaving10mmgapforthermalexpansion.110 mm |
| 113 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVCrainwaterpipesconformingto IS:13592 TypeAincludingjointingwith seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.Bend 87.5 degree110 mm Bend |
| 114 | Shoe (Plain)110 mm Shoe |
| 115 | Providingandfixingtotheinletmouthof rain water pipe cast iron grating 15 cm diameterandweighingnotlessthan440grams. |
| 116 | Providing and fixing unplasticised-PVC pipe clipsofapproveddesigntounplasticised- PVC rain water pipes by means of 50x50x50 mmhard wood plugs,screwed withMS screwsofrequiredlengthincludingcutting brickworkandfixingincementmortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 117 | Providingandfixing15cm wide45cm over all semi circular plain G.S. sheet gutter with ironbrackets40x3mmsize,bolts,nutsand washers etc. including making necessary connections with rain water pipes complete.0.80mm thick with zinc coating not less than275 gm/m2 |
| 118 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4(1cement:2coarsesand:4graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,roundingtheedgesand making and finishing the outlet complete. |
| 119 | ProvidingandfixingChlorinatedPolyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply includingallCPVCplain&brassthreaded fittingsi/cfixingthepipewithclampsat 1.00mspacing. Thisincludesjointingof pipes & fittings with one step CPVC solvent cementandthecostofcuttingchasesand making good thesame includingtestiang of joints complete as per directionof Engineerin Charge.Concealed work including cutting chases andmaking good the walls etc.20mm dia nominal outer dia pipes |
| 120 | 25mm dia nominal outer dia pipes |
| 121 | 32mm dia nominal outer dia pipes |
| 122 | Providingandfixinggunmetalgatevalvewith wheel of approved quality.25mm dia nominal bore |
| 123 | 32mm dia nominal bore |
| 124 | 40mm dia nominal bore |
| 125 | Providing and placing on terrace (at all floor levels)polyethylenewaterstoragetankISI: 12701markedindicatingtheBISLicense No.withcoverandsuitablelocking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent havingvalid ISI license].Capcity in Per Liters |
| 126 | Excavatingtrenchesofrequiredwidthfor pipes,cablesetc.includingexcavationfor socketsanddressingofsides,rammingof bottoms,depthupto1.5mincludinggetting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cmindepthincludingconsolidatingnos depositedlayerbyramming,wateringetc. anddisposingofsurplusexcavatedsoilasdirected, within a lead of 50m.All kinds of soilPipes,cablesetc.exceeding80mmdiabutnot exceeding 300mm. |
| 127 | Providing,layingandjointingglazed stonewarepipes grade\"A\" withstiff mixture of cement mortar in the proportion of 1:1 (1 cement:1finesand)includingtestingof joints etc. complete.100mm diameter |
| 128 | Providing and laying cement concrete 1:5:10 (1cement:5coarsesand:10gradedstone aggregate 40mm nominal size) all roundS.W.pipesincludingbedconcreteasper100mm dia SW pipe |
| 129 | ProvidingandlayingNon pressure NP2 class(lightduty)RCCpipewithcollars jointed withstiffmixtureofcement mortar intheproportionof1:2(1cement:2fine sand ) includingtestingof joints etc.150 mm.dia. RCCPipes |
| 130 | Providing and laying cement concrete 1:5:10 (1cement:5coarsesand:10gradedstone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design150 mm.dia. RCCPipes |
| 131 | Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating,brickmasonrychamberwithwater tight C.I. cover with frame of 300 x300 mm size(inside)theweightofcovertobenot lessthan4.50kgandframetobenotless than 2.70 kg as per standard design150 x 100 mm size P type With Sewer bricks conforming to IS : 4885 |
| 132 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand)RCCtopslabwith1:2:4mix(1cement:2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1cement:4coarsesand:8gradedstone aggregate40mmnominalsize)inside plastering12mmthickwithcementmortar 1:3(1cement:3coarsesand)finishedwith floatingcoatfoneatcementandmaking channels in cement concrete 1:2:4 (1 cement:2coarsesand:4gradedstoneaggregate 20mmnminalsize)finishedwithafloating coat of neat cement complete as per standard design.Inside size 90x80cms and 45cms deep includingCIcoverwithframe(lightduty) 455x610mminternaldiamensionstotal weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight offrame 15kg).With FPS bricks of class designation 75(i) For Sewer Line Extra for depth for manholes: |
| 133 | Size 90X80 cm with FPS bricks (class I ). |
| 134 | Providing M.S. foot rests including fixing in manholes with20x20x10 cmcement concreteblocks1:3:6(1 cement:3coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar |
| 135 | Providing and fixing on wall face unplasticised Rigid PVC soil and waste water pipes conforming to IS : 13592 Type B including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes.a) 110mm dia P.V.C. pipe |
| 136 | b) 90mm dia P.V.C. pipe |
| 137 | Providing & fixing UPVC Floor trap of self cleansingdesign withCPJali completein allrespects.(Make:Supreme/Finolex/Prince)P-Trap type Floor Trap 110 x 110mm |
| 138 | Providing and fixingterminal guard. a) 110mm |
| 139 | b) 90mm |
| 140 | Providing and fixing on wall face unplasticised-PVCmoulded fittings/accessories for unplasticised Rigid PVCpipes includingjointingwithseal ring leaving 10 mm gap for thermal expansion.110mm bend |
| 141 | 90 mm bend |
| 142 | 110mm |
| 143 | 90mm |
| 144 | 90x90x90 mm |
| 145 | 110x110x110 mm |
| 146 | Providing & fixing Towel Rail 300mm Long For Wash Basin Area |
| 147 | Providing & fixing Soap Dispenser with MetallicbottleJAQUARACN-CHR-1137N |
| 148 | Providing&fixingBottleTrap(With InternalPartition)32mmSizeWith250mm &190mmLongWallConnectionPipes& Wall Flange JAQUAR ALD-CHR-769 |
| 149 | ProvidingandfixingHandShower(Health Faucet) with 8mm Dia, 1 Meter Long FlexibleTube&WallHook(forE.W.C.) JAQUAR ALD-CHR-573 |
| 150 | ProvidingandfixingC.P.brassTwo-way anglevalveforEWCpoints&forfixing AblutionHealthFauctofapprovedquality conforming to15 mm nominal bore |
| 151 | Providing and fixing clean out plug110 mm dia. |
| 152 | TUBE WELL AND INSTALLATION OF SUBMERSIBLE PUMP (90 M. DEPTH)Boring/drillingborewellofrequireddiaforcasing/ strainer pipe,bysuitablemethodprescribedinIS:2800(partI), includingcollectingsamplesfrom differentstrata,preparing and submitting strata chart/ bore log, including hire & runningchargesofallequipments,tools,plants& machineries required for the job, all complete as per direction ofEngineer-in-charge,upto90metredepthbelowgroundlevel.300 mm dia |
| 153 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessoriesetc.all complete,for all depths, asper directionof Engineer -in-charge.100 mm nominal size dia |
| 154 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS)pipeswithribs,conformingtoIS:12818,including hire & labour charges, fittings & accessories etc. allcomplete,foralldepths,asperdirectionofEngineer-in-100 mm nominal size dia |
| 155 | Gravelpackingintubewellconstructioninaccordancewith IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, allcomplete as per direction of Engineer-in-charge. |
| 156 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable wateryield without sand content (beyond permissible limit)withrequiredcapacityaircompressor,runningthe compressorforrequiredtimetillwellisfullydeveloped, measuringyieldofwellby“V”notchmethodoranyother approved method, measuring static level & draw down etc. by stepdraw down method, collectingwater samples& getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and directionof Engineer-in-charge. |
| 157 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of :100 mm dia |
| 158 | Providing and fixing M.S. clamp of required dia to the top of casing/housingpipeoftubewellasperIS:2800(partI), includingnecessarybolts&nutsofrequiredsizecomplete.100 mm clamp. |
| 159 | Providing and fixing Bail plug/ Bottom plug ofrequired dia tothebottomofpipeassemblyoftubewellasperIS:2800(part I). 100 mm dia. |
| 160 | SupplyofsubmersiblepumpofmakeKSB2.0 HPwithcontrol panel, support wire etc. complete. |
| 161 | Providing2corePVCinsulatedsubmersibblecablefrompump panel to submersible pump |
| 162 | ProvidingandfixingG.I.pipescompletewithG.I.fittingsincluding trenching and refilling etc. 32 mm dia nominal bore |
| 163 | Providing and fixing gun metal gate valve with C.I. wheel ofapprovedquality (screwed end) |
| 164 | Supply of 100mm dia Johnson screen. |
| 165 | Servant RoomEarth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-incharge.All kinds of soil |
| 166 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 167 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M25 grade with minimum cementcontent of 330 kg /cum |
| 168 | All works above plinth level upto floor V level, As in item 3 but for the lighter beams i.e.having spans upto 6 m. (Using 1:1.5:3 Mix concrete) |
| 169 | All works above plinth level upto floor V level, As in item 3 above but forslabs (Using 1:1.5:3 Mix concrete) |
| 170 | All works upto plinth level, As in item 3 but for the Footing (Using 1:1.5:3 Mix concrete) |
| 171 | All works above plinth level upto floor V level, As in item 3 but for the Column(Using 1:1.5:3 Mix concrete) |
| 172 | Reinforcement for RCC work including straightening, cutting,bending, placing in position complete. -Thermo-Mechanically Treated |
| 173 | Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete |
| 174 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc |
| 175 | Diluting and injecting chemical emulsion for POST- CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 176 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 177 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse |
| 178 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse |
| 179 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hingeswith necessary screws |
| 180 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Sal wood |
| 181 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 182 | Providing and fixing bright finished brass nos butt nos with necessary screws etc. complete125x85x5.5mm(heavy type) |
| 183 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :250x10 mm |
| 184 | Providing and fixing bright finished brass door latch with necessary screws etc. complete.300x16x5 mm |
| 185 | Providing and fixing bright finished brass handles with screws etc. complete.125 mm |
| 186 | Providing and fixing bright finished brass hangging type floor door stoper with necessary screws etc. compelte. |
| 187 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) |
| 188 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) |
| 189 | 12 mm cement plaster 1:3( 1 cement: 3 coarse sand) finished with a floating coat of near cement |
| 190 | Add for plaster drip course/ groove in plastered surface or moulding toR.C.C. projections. |
| 191 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 192 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shadeArea of slab over 0.50 sqm |
| 193 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/ 10 sqm) over and including priming |
| 194 | Finishing with Deluxe Multi surface paint system for interiors and exteriorsusing Primer as per manufacturers specifications :Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.80 ltr/10 sqm of approved brand and manufacture |
| 195 | Wall painting with acrylic emulsion paint, having VOC (Volatile OrganicCompound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to |
| 196 | French spirit polishing : Two or more coats on new works including a coat ofwood filler |
| 197 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured |
| 198 | Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete. |
| 199 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass |
| 200 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and |
| 201 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access |
| 202 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 203 | Servant Room ELECTRICALINSTALLATIONSWIRING POINTS AND SUBMAINSPoint wiring in PVC ConduitWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed mediumclass PVC conduit, with modularswitch,modularplate,suitableGIboxandearthingthe point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 204 | Power plug wiring in PVC conduit (2 x 4 sqmm.) :-Wiring for light/ power plug with 2X4 sq. mm FRLS PVCinsulatedcopperconductorsinglecorecableinsurface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulatedcopperconductorsinglecorecableforloopearthingas required. |
| 205 | Circuit / Sub main wiring in PVC conduit :-Wiringforcircuit/submainwiringalongwithearthwirewiththe followingsizesofFRLSPVCinsulatedcopperconductor,single corecableinsurface/recessedmediumclassPVCconduitas2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. Earth wire |
| 206 | 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire |
| 207 | 4 x 6 sq.mm. + 2 x 6 sq.mm. Earth wire |
| 208 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 209 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 210 | SupplyingandfixingoffollowingsizesofmediumclassPVC conduitalongwithaccessoriesinsurface/recessincludingcutting the wall and making good the same in case of recessed conduit as20 mm. |
| 211 | 25 mm. |
| 212 | 32 mm. |
| 213 | S/F light plug point modular type accessories :-Supplying andfixing suitable size GI boxwith modularplate and coverinfrontonsurfaceorinrecess,includingprovidingand fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required |
| 214 | S/F power plug point modular type accessories :-Supplying andfixing suitable size GI boxwith modularplate and coverinfrontonsurfaceorinrecess,includingprovidingand fixing6pin5/6&15/16Amodularsocketoutletand15/16A modular switch, connections etc. as required. |
| 215 | S/F modular type electronic fan regulator :-Supplyingandfixingtwomodulesteppedtypeelectronicfan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 216 | S/F modular type blanking plate :-Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 217 | S/F MODULAR BOXES, BASE & COVER PLATE :-Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular switches inrecessetc as required1 or 2 Module (75 mm x 75 mm) |
| 218 | DISTRIBUTIONBOARDS,MCB\"s, MCCB\"sANDSFU\"sSupplying and fixing following way, horizontal type three pole and neutral,sheetsteel,MCBdistributionboard,415V,onsurface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,dinbar,interconnections,powderpaintedincludingearthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door, horizontal type |
| 219 | 6 way (4 + 18), Double door, horizontal type |
| 220 | Supplying andfixing 5A to32A rating, 240/415V, 10kA, \"C\" curve,miniaturecircuit breakersuitableforinductive loadof followingpolesintheexistingMCBDBcompletewith connections, testing and commissioning etc. as required single pole |
| 221 | Supplying and fixing following rating, four pole, 415 V, isolator in theexistingMCBDBcompletewithconnections,testingand commissioning etc. as required40 amps. |
| 222 | 63 amps. |
| 223 | Supplying&fixingsinglepole,blankingplateintheexisting MCBDBcomplete etc. as required. |
| 224 | Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug topalongwith20A\"C\"curve,TPMCB,insheetsteelenclosure,on surface or in recess, with chained metal cover for the socket out let andcomplete with connections, testing and commissioning etc. as required. |
| 225 | G.I.EARTHINGEarthingwithG.I.earthplate600mm X600mm X6mm thick including accessories, and providing masonry enclosure with cover platehavinglockingarrangementandwateringpipeof2.7metre long etc. with charcoal/ coke and salt as required. |
| 226 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below groundasstripearthelectrode,includingconnection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be donebyoverlappingandwith2setsofG.I.nutbolt&spring washer spaced at 50mm) |
| 227 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 228 | ERECTIONOFLIGHTINGFIXTURESANDFANSInstallation,testingandcommissioningofceilingfan,including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mmFRLSPVCinsulated,copperconductor,singlecorecable, includingprovidingandfixingphenoliclaminatedsheetcoveron the fan box etc. as required. |
| 229 | Supply and fixing of LED Tube Light with batten suitable for up to1X22wattLEDtubelightfittingincludingtubeonSurface complete in all respect. CAT- AAA |
| 230 | Supply and fixing of 12 Watt to 15 Watt indoor Recess mounting LEDSquare Fittingfor ArmstrongCeiling havingPowder coated diecastaluminiumhousingwithextendedheatsink,diffuserof Polycarbonate meterial and driver set complete in all respect. CAT-AAA |
| 231 | Supplyandfixingofrecess/Surface/Pendentmountinground6 Watt8WattLEDDownLighterhavingPowdercoateddiecast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA |
| 232 | Supplyandfixingofrecessmountinground15to18WattLED DownLighterhavingPowdercoateddiecastaluminiumhousing withheatsink,diffuser/Reflectoranddriversetcompleteinall respect. CAT- AAA |
| 233 | PART (B) -- NON SCHEDULED ITEMS (AS PER MARKET RATES)Supply,Installation,Testingand Commissioningof 1200mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)Motor,classofinsulation:B,3Nosblades,30cm long down rod, 2 Nos canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum6.85, Air deliveryminimum215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speedcontrolandallremainingaccessoriesincludingsafetypin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.1200 mm sweep |
| 234 | Providing and fixing of following rating Four poleMCCB\"s at the incomerofMain/subdistributionboardswith connectionsetc. complete as required.100 Amp FP MCCB(16 KA) |
| 235 | Supplying, fixing, connecting, testing and commissioning of following rating,ISImarked(IS8828)240/415volts,10KA, MiniatureCircuitBreaker(MCB) ofsingle/double/three / fourpolesintheexistingMCBDBorinexistingMSenclosure complete in all respects.25 Amp. TP MCB |
| 236 | GUARD ROOMEarth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-incharge.All kinds of soil |
| 237 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 238 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M25 grade with minimum cementcontent of 330 kg /cum |
| 239 | All works above plinth level upto floor V level, As in item 3 but for the lighter beams i.e.having spans upto 6 m. (Using 1:1.5:3 Mix concrete) |
| 240 | All works above plinth level upto floor V level, As in item 3 above but forslabs (Using 1:1.5:3 Mix concrete) |
| 241 | All works upto plinth level, As in item 3 but for the Footing (Using 1:1.5:3 Mix concrete) |
| 242 | All works above plinth level upto floor V level, As in item 3 but for the Column(Using 1:1.5:3 Mix concrete) |
| 243 | Reinforcement for RCC work including straightening, cutting, bending, placing in position complete. -Thermo-Mechanically |
| 244 | Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete |
| 245 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc |
| 246 | Diluting and injecting chemical emulsion for POST- CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 247 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 248 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse |
| 249 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse |
| 250 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hingeswith necessary screws |
| 251 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Sal wood |
| 252 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 253 | Providing and fixing bright finished brass nos butt nos with necessary screws etc. complete125x85x5.5mm(heavy type) |
| 254 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :250x10 mm |
| 255 | Providing and fixing bright finished brass door latch with necessary screws etc. complete.300x16x5 mm |
| 256 | Providing and fixing bright finished brass handles with screws etc. complete.125 mm |
| 257 | Providing and fixing bright finished brass hangging type floor door stoper with necessary screws etc. compelte. |
| 258 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) |
| 259 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) |
| 260 | 12 mm cement plaster 1:3( 1 cement: 3 coarse sand) finished with a floating coat of near cement |
| 261 | Add for plaster drip course/ groove in plastered surface or moulding toR.C.C. projections. |
| 262 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 263 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with whitecement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shadeArea of slab over 0.50 sqm |
| 264 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/ 10 sqm) over and including priming |
| 265 | Finishing with Deluxe Multi surface paint system for interiors and exteriorsusing Primer as per manufacturers specifications :Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.80 ltr/10 sqm of approved brand and manufacture |
| 266 | Wall painting with acrylic emulsion paint, having VOC (Volatile OrganicCompound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to |
| 267 | French spirit polishing : Two or more coats on new works including a coat ofwood filler |
| 268 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured |
| 269 | Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete. |
| 270 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for |
| 271 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers |
| 272 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and |
| 273 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and |
| 274 | Gaurd Room ELECTRICALINSTALLATIONSWIRING POINTS AND SUBMAINSPoint wiring in PVC ConduitWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed mediumclass PVC conduit, with modularswitch,modularplate,suitableGIboxandearthingthe point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 275 | Power plug wiring in PVC conduit (2 x 4 sqmm.) :-Wiring for light/ power plug with 2X4 sq. mm FRLS PVCinsulatedcopperconductorsinglecorecableinsurface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulatedcopperconductorsinglecorecableforloopearthingas required. |
| 276 | Circuit / Sub main wiring in PVC conduit :-Wiringforcircuit/submainwiringalongwithearthwirewiththe followingsizesofFRLSPVCinsulatedcopperconductor,single corecableinsurface/recessedmediumclassPVCconduitas2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. Earth wire |
| 277 | 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire |
| 278 | 4 x 6 sq.mm. + 2 x 6 sq.mm. Earth wire |
| 279 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 280 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 281 | SupplyingandfixingoffollowingsizesofmediumclassPVC conduitalongwithaccessoriesinsurface/recessincludingcutting the wall and making good the same in case of recessed conduit as20 mm. |
| 282 | 25 mm. |
| 283 | 32 mm. |
| 284 | S/F light plug point modular type accessories :-Supplying andfixing suitable size GI boxwith modularplate and coverinfrontonsurfaceorinrecess,includingprovidingand fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required |
| 285 | S/F power plug point modular type accessories :-Supplying andfixing suitable size GI boxwith modularplate and coverinfrontonsurfaceorinrecess,includingprovidingand fixing6pin5/6&15/16Amodularsocketoutletand15/16A modular switch, connections etc. as required. |
| 286 | S/F modular type electronic fan regulator :-Supplyingandfixingtwomodulesteppedtypeelectronicfan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 287 | S/F modular type blanking plate :-Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 288 | S/F MODULAR BOXES, BASE & COVER PLATE :-Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular switches inrecessetc as required1 or 2 Module (75 mm x 75 mm) |
| 289 | DISTRIBUTIONBOARDS,MCB\"s, MCCB\"sANDSFU\"sSupplying and fixing following way, horizontal type three pole and neutral,sheetsteel,MCBdistributionboard,415V,onsurface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,dinbar,interconnections,powderpaintedincludingearthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door, horizontal type |
| 290 | 6 way (4 + 18), Double door, horizontal type |
| 291 | Supplying andfixing 5A to32A rating, 240/415V, 10kA, \"C\" curve,miniaturecircuit breakersuitableforinductive loadof followingpolesintheexistingMCBDBcompletewith connections, testing and commissioning etc. as required single pole |
| 292 | Supplying and fixing following rating, four pole, 415 V, isolator in theexistingMCBDBcompletewithconnections,testingand commissioning etc. as required40 amps. |
| 293 | 63 amps. |
| 294 | Supplying&fixingsinglepole,blankingplateintheexisting MCBDBcomplete etc. as required. |
| 295 | Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug topalongwith20A\"C\"curve,TPMCB,insheetsteelenclosure,on surface or in recess, with chained metal cover for the socket out let andcomplete with connections, testing and commissioning etc. as required. |
| 296 | G.I.EARTHINGEarthingwithG.I.earthplate600mm X600mm X6mm thick including accessories, and providing masonry enclosure with cover platehavinglockingarrangementandwateringpipeof2.7metre long etc. with charcoal/ coke and salt as required. |
| 297 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below groundasstripearthelectrode,includingconnection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be donebyoverlappingandwith2setsofG.I.nutbolt&spring washer spaced at 50mm) |
| 298 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 299 | ERECTIONOFLIGHTINGFIXTURESANDFANSInstallation,testingandcommissioningofceilingfan,including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mmFRLSPVCinsulated,copperconductor,singlecorecable, includingprovidingandfixingphenoliclaminatedsheetcoveron the fan box etc. as required. |
| 300 | Supply and fixing of LED Tube Light with batten suitable for up to1X22wattLEDtubelightfittingincludingtubeonSurface complete in all respect. CAT- AAA |
| 301 | Supply and fixing of 12 Watt to 15 Watt indoor Recess mounting LEDSquare Fittingfor ArmstrongCeiling havingPowder coated diecastaluminiumhousingwithextendedheatsink,diffuserof Polycarbonate meterial and driver set complete in all respect. CAT-AAA |
| 302 | Supplyandfixingofrecess/Surface/Pendentmountinground6 Watt8WattLEDDownLighterhavingPowdercoateddiecast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA |
| 303 | Supplyandfixingofrecessmountinground15to18WattLED DownLighterhavingPowdercoateddiecastaluminiumhousing withheatsink,diffuser/Reflectoranddriversetcompleteinall respect. CAT- AAA |
| 304 | PART (B) -- NON SCHEDULED ITEMS (AS PER MARKET RATES)Supply,Installation,Testingand Commissioningof 1200mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)Motor,classofinsulation:B,3Nosblades,30cm long down rod, 2 Nos canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum6.85, Air deliveryminimum215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speedcontrolandallremainingaccessoriesincludingsafetypin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.1200 mm sweep |
| 305 | Providing and fixing of following rating Four poleMCCB\"s at the incomerofMain/subdistributionboardswith connectionsetc. complete as required.100 Amp FP MCCB(16 KA) |
| 306 | Supplying, fixing, connecting, testing and commissioning of following rating,ISImarked(IS8828)240/415volts,10KA, MiniatureCircuitBreaker(MCB) ofsingle/double/three / fourpolesintheexistingMCBDBorinexistingMSenclosure complete in all respects.25 Amp. TP MCB |
| 307 | UNDER GROUND WATER TANKEarth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil |
| 308 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement: 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derivedfrom natural sources) |
| 309 | Providing and laying in position speccific grade of reincorced cement concreteexcluding the cost of centering and shuttering - All work up to plinth level : 1:1.5:3(1 Cement : 1.5coarse sand:3 graded stone aggregatederived from natural sources |
| 310 | Reinfoced Cement Concrete work in walls (of any thickness ) including,pillasters buttresses plinth and string courses 1:1.5:3(1 Cement : 1.5coarse sand:3 graded stone aggregatederivedfrom natural sources |
| 311 | Reinfoced Cement Concrete work in beams, suspended floor 1:1.5:3(1 Cement : 1.5coarse sand:3 graded stone aggregatederived from natural sources |
| 312 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 313 | Centring &shuttering of walls (any thickness) including attaches pillasters , buttresses,plinth and string courses |
| 314 | Providing and fixing in position pre cast RCCMain holecover of required shapeand approved qualityRectangular shape 600x450mm internaldimesnions |
| 315 | Boundry Wall(V.C. Residence)Contsruction of Boundry wall as per drawing with all complete. As per direction of Engineer In Charge |
| 316 | EXTERNAL ELECTRIFICATION & LANDSCAPE LIGHTINGSupply & Fixingof’ 5mtr long Antique designed pole with castaluminium/ironbasewithgalvanized steelpipeand decorativetoppaintedwithprimerthenpaintedwithdull finished polyurethane paint fitted with MCB and connector withdecorativebracketsinglearmformountingof1nos drop down lantern with body made out ofspun aluminium and fitted with poly carbonate diffuser in 110W with built in surge protector and lumn output>110lmn/watt. Design as perArchitectincharge. (Make-Twinklelite/wipro/K Lite/ Luster) |
| 317 | Supplying Testing & Installation of Led Flood Light Luminaire50W PhilipsMakeModel-BVP140Led50 CW PSU WH/ Wipro/ Luster etc all complete of directionof engineer in charge. |
| 318 | Supplying Testing & Installation ofLed Flood Light Luminaire 100WV Philips Make Model- BVP 142 Led 100 CW PSU WH / Wipro/ Lusteretc all complete of direction of engineer in charge. |
| 319 | Supply and fixing of decorative16 Watt LEDbollard luminaire with driver set confirming to IP 65 protection complete in all respect. |
| 320 | Earthingwithcopperearthplate 600mm X600mm X 3 mmthickincludingaccessories,andprovidingmasonry enclosure with cover plate having locking arrangement and wateringpipeof2.7metrelongetc.withcharcoal/cokeand salt as required |
| 321 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 322 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metrebelowgroundasstripearthelectrode,including connection/terminatingwithnut,bolt,spring,washeretc. as required. (Jointing shall be done by overlapping and with 2 sets of brassn nut bolt & spring washer spaced at 50mm) |
| 323 | Supply and layingofaluminium conductorPVCinsulated armouredservedsheathedcables1100Voltsgradeata depth of 750 mm below ground level over a cushion of 75mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S.clampsetc.ofsuitablesizeorasdirectedby the Engineer-Incharge ,complete in all respect. The armouring ofthecableshallbeproperlyconnectedwiththeearth conductor by clamps etc.6.00 Sqmm 4 Core |
| 324 | 25.00 Sqmm 3.5 Core |
| 325 | 70.00 Sqmm 3.5 Core |
| 326 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect.40 A TPN |
| 327 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench,complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 328 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 329 | LANDSCAPE & HORTICULTUREProvidingandstackingofBottlepalmofht.270-300 cm bottom girth 40-50cm well developed in big HDPE bags as per diection of the officer-in-charge. |
| 330 | ProvidingandstackingofFicusbenjamina(green)of height150-165cm.,bushywithhealthybranchesand lush green foliage in big size HDPE bags as perdirection of the officer-in-charge. |
| 331 | Providing and stacking of Ficus bengalensis krishna of height 75-90 cm., multibranched in earthen pots of size 30 cm as per direction of the officer-in-charge |
| 332 | ProvidingandstackingofTectonagrandis(Teak)of height 150-165 cm. in big polybags of size 25 cm as perdirection of the officer-in-charge. |
| 333 | ProvidingandstackingofWashingtoniafilifeapalm stem ht. 90-105cm with6-7healthy leaveslushgreen leaveswelldevelopedinbigsizeHDPEBagsasperdirection of the officer-in-charge. |
| 334 | Providing and Displaying Sunflower hybrid well developed 15 to 20 cm ht. with fresh & healthy foliage at blooming stage in 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge. |
| 335 | Providing and Displaying Creeper Rose variety 3 to 4 healthy branch 60 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer-in-charge. |
| 336 | Providing and Displaying Standard Rose (H.T. variety) 3 to 4 healthy branch 90 cm and above ht. well developed with one and above flowers in 25 Earthen Pot, as per direction of the officer-in-charge. |
| 337 | Providing and Displaying Bamboo Buddha vally variety with umbrella shape having 120 to 135 ht. with fresh & healthyfoliagewelldevelopedin40cmCementpot multy branch,bushy asperdirectionoftheofficer-in- charge. |
| 338 | Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per directionof the officer-in-charge. |
| 339 | Providing and stacking of Plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. |
| 340 | Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushty shape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & asper direction of the officer-in-charge.. |
| 341 | Trenchinginordinarysoiluptorequireddepth including removal and stacking of serviceable materialsandthendisposingofasdirectedand spreadingearth&neatly levelling,breakingclods etc.andmakingthetrenchedareawithdesigned mounds,pathsandsittingspacesetc.toproper levelsbyfillingwithearthorearthmixedwith manureandproperlywateringcompleteworkin required topography as per drawing &specifications. |
| 342 | Supplying and stacking of good earth at site including royalty but including carriage1km (earth measusredinstackswillbereducedby20%for |
| 343 | Supplying andstacking atsitedumpmanure from approved source,includingcarriageupto1km (manure measured in stacks will be reduced by8%for payment) |
| 344 | Mixing earth and manure in specified proportion oras directed. |
| 345 | Rough dressing the trenched ground includingbreaking the clods. |
| 346 | Fine dressing the ground |
| 347 | Spreadingof mixedgoodearthandmanurein specified proportions as aboveand inrequiredthickness. |
| 348 | Uprooting weeds from the trenched area after 10 to15 days after flooding with water including disposal of uprooted vegetation. |
| 349 | Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness on existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface withlightrollermakethesurfacesmoothenand light watering the same, as per direction of officerin charge |
| 350 | Preparation of mounds of various size and shape by availableexcavated/suppliedearthinlayersnot exceeding 20 cm in depth, breaking clods, watering of nos layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge. |
| 351 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering |
| 352 | TREMIX PARKINGExcavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 353 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 354 | Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete. |
| 355 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 356 | Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete. |
| 357 | Mildsteel or ironinplainworksuchas reinforcedconcrete orreinforced ,brick work (when not includedin anover all rates )wrought to required shapeas necessary including bendingforproper completion of theworkand includingsupplyof steelitswastage bendhooksand authorised overlapping shallbe measured upto floor two level. |
| 358 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 359 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of jointsexcept at sharp curve shall not to more than 5mm), including making drainage opening whereverrequired complete etc. as per direction of Engineer- in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 360 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 361 | PATHWAYEarth workin excavation bymechanicalmeans (Hydraulicexcavator)/manualmeansoverareas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto1.5m,asdirectedbyEngineer-incharge.Allkinds of soil |
| 362 | Providing and laying in position cement concrete of specified grade excluding the cost ofcentering and shuttering-Allworkuptoplinthlevel:1:4:8(1 Cement:4coarsesand(zone-III)derivedfrom naturalsources:8gradedstoneaggregate40mmnominal size derived from natural sources) |
| 363 | Providing and laying factory made chamferededge CementConcretepaverblocksinfootpath,parks, lawns,drivewaysorlighttrafficparkingetc,of required strength, thickness & size/ shape, made by tablevibratorymethodusingPUmould,laidin requiredcolour&patternover50mmthick compacted bed of sand, compacting andproper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per requiredsizeandpattern,finishingandsweeping extra sand. complete all as per direction of Engineer in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 364 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in positiontotherequiredline,levelandcurvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves(thicknessofjointsexceptatsharpcurve shallnottomorethan5mm),includingmaking drainageopeningwhereverrequiredcompleteetc. asperdirectionofEngineer-in-charge(lengthof finished kerb edging shallbe measured for payment). (Precast C.C. kerb stone shall be approvedby Engineer-in-charge). |
| 365 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil |
| 366 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominalsize) |
| 367 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cementcontent, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Concrete of M25 grade with minimum cement content of 330 kg /cum All works above plinth level upto floor V level |
| 368 | As in item 4 above but forslabs |
| 369 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-MechanicallyTreated bars |
| 370 | GATEProviding and fixing M.S. grills of required pattern in frames of windows / Gate etc. withM.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 371 | RAIN WATER HARVESTING PITSEarthworkinexcavationbymechanical means (Hydraulic excavator) / manual meansinfoundationtrenchesordrains (notexceeding1.5minwidthor10sqm onplan),includingdressingofsidesand ramming of bottoms, lift upto 1.5 m, includinggettingouttheexcavatedsoil anddisposalofsurplusexcavatedsoilas directed, within a lead of 50 m.All kinds of soil |
| 372 | Brick work with common burnt clay F.P.S. (nonmodular)bricksofclassdesignation7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cementmortar1:6(1cement:6coarsesand) |
| 373 | CEMENTPLASTERWITHAFLOATINGCOAT OF NEAT CEMENT12mmcementplasterfinished withafloating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand) |
| 374 | Reinforcedcementconcreteworkin beams, suspended floors, roofs having slopeupto15°landings,balconies, shelves,chajjas,lintels,bands,plain window sills, staircases and spiral stair casesaboveplinthleveluptofloorfive level, excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3(1cement:1.5coarsesand (zone-III):3gradedstoneaggregate20 mm nominal size). RCC(1cement:1.5corasesand:3stoneaggregate) |
| 375 | FORM WORKCenteringandshutteringincluding strutting, propping etc.and removal of form for all heights :Centeringandshutteringincluding strutting, propping etc.and removal of form for all heights : Suspended floors, roofs, landings,balconies and access platform |
| 376 | STEEL REINFORCEMENTSteel reinforcement for R.C.C.work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. Hot rolled deformed bars |
| 377 | Boring/drillingborewellofrequireddia forcasing/strainerpipe,bysuitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/borelog,includinghire&running charges of all equipments, tools,plants & machineriesrequiredforthejob,all completeasperdirectionofEngineer-in- charge,upto90metredepthbelow ground level.All types of soil300mm dia |
| 378 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM)pipeofrequireddia,conformingto IS: 12818, including required hire and labourcharges,fittings&accessoriesetc. allcomplete,foralldepths,asper direction of Engineer -in-charge.150 mm nominal size dia |
| 379 | Supplying, filling, spreading & leveling stonebouldersofsizerange5cmto20 cm,inrechargepit, inthe required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 380 | Supplying, filling, spreading & leveling gravelsofsizerange5mmto10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 381 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all completeasperdirectionofEngineer-incharge |
| 382 | Gravel packing in tubewell construction in accordancewithIS:4097,including providinggravelfine/medium/coarse,in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 383 | ProvidingandfixingM.S.clampof required dia to the top of casing/ housing pipeoftubewellasperIS:2800(partI), includingnecessarybolts&nutsof required size complete.150 mm clamp |
| 384 | Providing and fixing Bail plug/ Bottom plug of required dia to thebottomofpipeassemblyoftubewellas per IS:2800 (part I).150mm dia |
| 385 | Providing,fixinginpositionofISImarked UVstabilizedUPVCpipes forventing, Type-B as per IS : 13592 suitable for rubberringjointsforverticalpipesand solvent cement joints for horizontal pipes, includingallneccessaryspecialsand fittings (Make : Finalex/ Astral / Ashirwad) 75mmdia(WallThickness-3.2to3.8mm) |
| 386 | Providingandfixinginpositionpre-castR.C.C. manhole cover andframe of required shape and approved quality Rectangularshape600x450mminternaldimensions |
| 387 | Providingorangecoloursafetyfootrest of minimum 6 mm thick plastic encapsulatedasperIS:10910,on12mm dia. Steel bar conforming to IS:1786, having minimum cross section as 23mm x 25mmandoverallminimumlength263 mm and width as 165 mm with minimum112 mm space between protruded leg having 2 mm tread on top surface by ribbingorchequeringbesidesnecessary andadequatedanchoringprojectionson taillengthon138mmasperstandard drawingandsuitabletowithstandthe bendtestandchemicalresistancetestas per spaecifications and having manufacture\"spermanentidentification mark to be visible even after fixing, includingfixinginmanholeswith 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate20mmnominalsize)complete as per design. |
| 388 | DG SET, SOLER PLANT,CCTV AND VRV/VRF SYSTEM ACSupplying, installation, testing and commissioning of silent type DG sets, AMF panel, bus ducting/ cables from DG sets to. essential panel, synchronizing panel where réquired, DG set enclosure room sound insulation/ventilation/smoke exhaust as required, earthing of DG set system, control cabling, fuel tank/piping, DG set exhaust piping/ exhaust chimney as per CPCB norms, civil works connected with DG sets including foundation as required. |
| 389 | Supplying, installation, testing and commissioning of VRV/VRF system including indoor/outdoor units, piping, electrical power distribution/wiring, electrical panel, treated fresh air system etc. |
| 390 | Supplying, installation, testing and commissioning of grid interactive roof Top solar photo voltaic power generation system including space frame |
| 391 | Supplying, installation, testing and commissioning of IP based CCTV system for building security comprising of PTZ / fixed camera, cabling, recording, display system and hard ware software support - for indoors only {Rate applicable on total plinth area). |
| 392 | Supplying, installation, testing and commissioning of lift for 08 person JOHNSON, OTIS OR ANY APPROVED BRAND |
| 393 | SECRETARY RESIDENCEBUILDING WORKEarth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil |
| 394 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating nos deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m |
| 395 | Diluting and injecting chemical emulsion for PRE- CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 396 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 397 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 398 | Providing centering & shuttering including strutting, propping etc. & removal of form including all materials, labour and T & P etc. required for proper completion of work all completeFoundation, Footing, base of columns and plinth beam in any shape and size upto plinth level. |
| 399 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 400 | Lintels, beams, plinth beams, girders, bressumers andcantilevers |
| 401 | Suspended floors, roofs, landings, balconies and accessplatform |
| 402 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in- charge; for the following grades of concrete. Note: Extracement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cumAll works up to Plinth level. |
| 403 | All works AbovePlinth level & upto Floor V Level |
| 404 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 405 | Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement Mortar 1:4 (1 cement : 4 coarse sand) |
| 406 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 407 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement :3coarse sand) |
| 408 | 15 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) |
| 409 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) |
| 410 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) |
| 411 | Making grooves 10 to 12mmwidex 8mm deep in plaster of the wallor in ceiling vertically or horizontally as required. |
| 412 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).Second class teak wood |
| 413 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 414 | Providing & fixingsystem Profile Aniodised Aluminium Window all complte as per direction of enginner in chargeFixed part |
| 415 | Providing & fixingsystem Profile Aniodised Aluminium Window all complte as per direction of enginner in chargeCasement window with top pin |
| 416 | Providing & fixingsystem Profile Aniodised Aluminium Window all complte as per direction of enginner in charge Slider 3T 3P Triple track (Tostom , Schuco) |
| 417 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc |
| 418 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). |
| 419 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 420 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacture\"s specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work |
| 421 | French spirit polishing :Two or more coats on new worksincluding a coat of wood filler |
| 422 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coatwith cement primer |
| 423 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @2.20kg/10 sqm |
| 424 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smoothcomplete. |
| 425 | Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. (Make Hilti/ Fisher/ Helifix)Frame anchor HRD-C 10x140 |
| 426 | Providing and fixing aluminium sliding door bolts, ISI marked anodised anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm |
| 427 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, withnecessary screws etc. complete : 200x10 mm |
| 428 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessaryscrews etc. complete : 125 mm |
| 429 | Cement concrete flooring with cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement..(40mm thick with 20 mm nominal aggregate). |
| 430 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. IN : toilet Block |
| 431 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 432 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete Double charged Vitrified Tile Polish finish Size 1200x600 mm |
| 433 | Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red Area of slab over 0.50 sqm |
| 434 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarsesand) : 25 mm thick |
| 435 | Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shapedwashers etc. complete. |
| 436 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 437 | Providingandlayingintegralcementbasedwaterproofing treatment including preparation of surfaceas required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using2.75kg/sqmofcementadmixedwithwaterproofing compound conforming to IS. 2645 and approved by Engineer- in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conformingtoIS: 2645andapprovedby Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement:5coarsesand)admixed withwater proofingcompound conforming to IS : 2645 and approved by Engineer-in-charge to requiredslopeandtreatingsimilarlytheadjoiningwallsupto300mm heightincludingroundingofjunctionsofwallsandslabsc) Aftertwodaysofpropercuringapplyingasecondcoatof cement slurry using 2.75 kg/ sqm of cement admixed jointless cementmortarofmix1:4(1cement :4coarse sand) admixed withwaterproofingcompoundconformingtoIS:2645and |
| 438 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm nos having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips madeout of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and alsoincluding the cost of making openings for light fittings, grills, diffusers, |
| 439 | Providing and fixing a wooden false ceiling including frame, cladding, finishing, and necessary hardware, complete as per design, drawing, and direction of Engineer-in-Charge Material: Seasoned hardwood or commercial-grade pine wood Size: 50 x 25 mm or as specified Treatment: Anti-termite and fire-retardant treatmentSpacing: 600 mm c/c both ways or as per design requiremen |
| 440 | Providing and fixing Murga Jali-type false ceiling (wire mesh ceiling) with steel framework, suspended from the main ceiling, including finishing, suspension, framing, painting (if any), complete as per drawing and instructions of Engineer-in-Charge. |
| 441 | Providing and fixing of PVC‐laminated false ceiling / panels manufactured by Skydecor (or equivalent), including frame, accessories, finish, cutouts & openings, complete as per drawings, manufacturer’s instructions, and direction of Engineer‐in‐Charge. (Skydecor or equivalent) |
| 442 | Providing and laying Italian marble of 18 mm thickness (polished finish) over prepared screed/substrate with polymer-modified thin-set adhesive, jointing with matching grout, polishing, sealing, and finishing, complete as per manufacturer’s specifications and Architect’s direction. |
| 443 | 25mm wooden planking , toungue and grooved in flooring, including fixing with screws with second class teak wood |
| 444 | Providing, supplying, and laying Stonex paving slabs / driveway stones over prepared base, with bedding, jointing, finishing, and all associated works, for vehicle traffic, complete as per drawings, manufacturer’s instructions, and Engineer‑in‑Charge directions |
| 445 | Providing and installing a fully modular, high-end kitchen setup including base units, wall units, tall units, and integrated accessories. The carcass shall be made of 18 mm BWP (Boiling Water Proof) grade plywood (IS 710), laminated internally with 1 mm white laminate and all edges sealed with matching PVC edge banding. Shutters shall be finished in high-gloss PU paint / acrylic laminate / veneer with PU polish or lacquered glass, mounted on soft-close hinges (Hettich/Blum), with drawers fitted with soft-close tandem channels. Lift-up systems shall be provided in overhead cabinets where applicable. Handle-less profile or designer handles shall be used as per the approved design. The countertop shall be made of premium 18–20 mm thick Quartz / Granite or large format porcelain slab with matching backsplash up to the overhead cabinets. A double bowl under-mount sink in stainless steel (Franke/Nirali/Blanco) with a designer pull-out faucet shall be provided. The under-sink cabinet shall have a waterproof base and built-in cleaning tray. Accessories include modular cutlery trays, bottle pull-outs, corner carousels or magic corners, pull-out pantry units, and dual-bin waste segregation systems. |
| 446 | Supplying, installing, testing, and commissioning of kitchen chimney of wall-mounted / island type as per layout, with suction capacity not less than [900–1200 m³/hr], auto-clean technology, stainless steel or glass finish, baffle filters / filterless, complete with ducting (PVC/Aluminium flexible), clamps, wall sleeve, exhaust cap, electrical connection, and all accessories for proper functioning, including making cut-outs in masonry/plywood for ducts and making good the same, all complete as per approved make, technical specifications, and instructions of the Engineer-in-Charge |
| 447 | High-Pressure Laminate (HPL) exterior façade includes supply and installation of weather-resistant HPL panels (typically 6-8mm thick) fixed on an aluminum or galvanized steel subframe. Panels are UV-stabilized, fire-rated, and come in various finishes. The scope covers mechanical fasteners, EPDM gaskets, sealants, and necessary support brackets, ensuring proper ventilation and thermal movement allowance. Rates generally range from ₹750 to ₹1,400 per sq. meter, including materials and labor, with a recommended 5-10% wastage. Final costs depend on panel brand, façade area, and site conditions. (Findermax or equiavlent ) |
| 448 | Material: Aluminum Composite Panel (typically 4mm thickness) Finish: PVDF or Polyester coated, weather and UV resistantSub-frame: Aluminum or GI framing with brackets and fastenersTypical Rate: ₹900 to ₹1,600 per sqm (including supply, fabrication, and installation)Includes: ACP panels, substructure, fixings, sealants, andlabor Note: Rates vary depending on brand, panel thickness, coating type, and site conditions |
| 449 | Providing and fixing exterior-grade thin brick veneer tiles (approx. 2¼\" x 7⅝\", thickness ½\"–¾\"), of approved make, size, color, and texture, in [running bond / herringbone / stack bond] pattern, laid over prepared substrate with polymer-modified thin-set mortar or Type N/S cement mortar, including surface preparation, corner units, control joints, pointing, cleaning, and necessary scaffolding, all complete as per drawings, specifications, and instructions of the Engineer-in-Charge |
| 450 | Providing and fixing mica laminate finish (decorative high-pressure laminate) of approved make, shade, and thickness (typically 1.0 mm) on furniture surfaces / wall paneling / partitions / doors, etc., using approved synthetic resin adhesive (Fevicol SH or equivalent) over prepared surface (e.g., BWP grade plywood, MDF, blockboard), including edge finishing, trimming, cleaning, and all tools, adhesives, materials, labour and incidentals, complete in all respects as per drawings and instructions of the Engineer-in-Charge (Sylvan , Green ply, Austin ) |
| 451 | ELECTRICALINSTALLATIONSWIRING POINTS AND SUBMAINSPoint wiring in PVC ConduitWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copperconductorsinglecorecableinsurface/ recessedmediumclassPVCconduit,with modularswitch,modularplate,suitableGIbox and earthing the point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable etc.Group C |
| 452 | Power plug wiring in PVC conduit (2 x 4sqmm.) :-Wiringforlight/powerplugwith2X4sq.mm FRLS PVCinsulatedcopperconductorsinglecorecablein surface/ recessed medium class PVC conduit alongwith1No.4sq.mmFRLSPVCinsulated copper conductor single core cable for loopearthing as required. |
| 453 | Circuit / Sub main wiring in PVC conduit :-Wiringfor circuit/submain wiringalongwith earth wire with the following sizes of FRLS PVC insulatedcopperconductor,singlecorecablein surface/recessedmediumclass PVCconduit asrequired.2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. Earth wire |
| 454 | 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire |
| 455 | 4 x 6 sq.mm. + 2 x 6 sq.mm. Earth wire |
| 456 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 457 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 458 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessedconduit as required20 mm. |
| 459 | 25 mm. |
| 460 | 32 mm. |
| 461 | S/F light plug point modular type accessories :-SupplyingandfixingsuitablesizeGIboxwith modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modularsocketoutletand5/6Amodularswitch,connections etc. as required |
| 462 | S/F power plug point modular type accessories :-SupplyingandfixingsuitablesizeGIboxwith modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 463 | S/F modular type electronic fan regulator :-Supplyingandfixingtwomodulesteppedtype electronicfanregulatorontheexistingmodular plateswitchboxincludingconnectionsbutexcluding modular plate etc. as required. |
| 464 | S/F modular type blanking plate :-Supplyingandfixingmodularblankingplateon the existing modular plate & switch box excludingmodular plate as required. |
| 465 | TELEPHONE, TELEVISION AND DATA NETWORKTELEPHONE WIRING IN EXISTING CONDUIT :-Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmoredtelephonecableintheexisting surface/ recessed steel/ PVC conduit as required2 Pair |
| 466 | S/F MODULAR BOXES, BASE & COVER PLATE :-Supplyingandfixing followingsize /modules, GI boxalongwithmodularbase&coverplatefor modular switches inrecessetc as required1 or 2 Module (75 mm x 75 mm) |
| 467 | S/F MODULAR TYPE SWITCH / SOCKET :-Supplyingandfixingfollowingmodularswitch/ socket on the existing modular plate & switch box including connections but excluding modular plateetc as requiredTelephone Socket outlet |
| 468 | DISTRIBUTIONBOARDS,MCB\"s, MCCB\"sANDSFU\"sSupplying and fixing following way, horizontal type threepoleandneutral,sheetsteel,MCB distribution board, 415V,onsurface/recess, complete with tinned copper bus bar, neutral bus bar,earthbar,dinbar,interconnections,powder paintedincludingearthingetc.asrequired.(Butwithout MCB/RCCB/Isolator)4 way (4 + 12), Double door, horizontal type |
| 469 | 6 way (4 + 18), Double door, horizontal type |
| 470 | Supplying andfixing 5A to32 A rating, 240/415 V,10kA,\"C\"curve,miniaturecircuitbreaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as requiredsingle pole |
| 471 | Supplyingandfixingfollowingrating,fourpole, 415 V, isolator in the existing MCB DB complete with connections,testing andcommissioning etc.as required40 amps. |
| 472 | 63 amps. |
| 473 | Supplying& fixing singlepole, blankingplate in the existing MCBDBcomplete etc. as required. |
| 474 | Supplying and fixing 20 A, 415 V, TPN Industrial type socketoutlet, with 4 pole and earth, metal enclosed plug topalongwith 20 A \"C\" curve, TPMCB, in sheet steel enclosure,onsurfaceorinrecess,withchained metalcoverforthesocketoutletandcomplete with connections,testing andcommissioning etc.as required. |
| 475 | G.I.EARTHINGEarthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with coverplate having lockingarrangementandwateringpipeof2.7 metrelongetc.withcharcoal/cokeandsaltasrequired. |
| 476 | Supplying and laying 25 mm X 5 mm G.I strip at0.50 metre below ground as strip earth electrode, includingconnection/terminatingwithG.I.nut, bolt,spring,washeretc.asrequired.(Jointing shallbedonebyoverlappingandwith2setsofG.I. nut bolt & spring washer spaced at 50mm) |
| 477 | Providingandfixing25mmX 5mmG.I.strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 478 | ERECTIONOFLIGHTINGFIXTURESANDFANSInstallation,testingandcommissioningofceiling fan,includingwiringthedownrodsofstandard length(upto30cm)with1.5sq.mmFRLS PVC insulated,copperconductor,singlecorecable, includingprovidingandfixingphenoliclaminated sheet cover on the fan box etc. as required. |
| 479 | Installation of exhaust fan in the existing opening, includingmakinggoodthedamage,connection, testing, commissioning etc. as required. Upto 450mm sweep |
| 480 | SupplyandfixingofLEDTubeLightwithbatten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect.CAT- AAA |
| 481 | Supplyandfixingof12Wattto15Wattindoor RecessmountingLEDSquareFittingfor Armstrong Ceiling having Powder coated die cast aluminium housing with extended heat sink, diffuserofPolycarbonatemeterialanddriversetcomplete in all respect. CAT- AAA |
| 482 | Supplyandfixingofrecess/Surface/Pendent mounting round 6 Watt 8 Watt LED Down Lighter havingPowdercoateddiecastaluminium housingwithheatsink,diffuser/Reflectorand driver set complete in all respect. CAT- AAA |
| 483 | Supply and fixing of recess mounting round 15 to 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflectoranddriversetcompleteinallrespect. CAT- AAA |
| 484 | Supply and fixing of sqaure Light 40-60Watt LED DownLight(600x600)mmhavingPowder coated die cast aluminium housing with heat sink, diffuser/Reflectoranddriversetcompleteinallrespect. |
| 485 | Providing & Fixing of modular plate type white RJ 45CAT6Dataoutlet/informationoutletsETL verifiedtomeetorexceedTIA/EIAcategory6 requirements,universalwiringlabelpermittingto eitherT568AorT568B,ULlisted, forcomputer networking completeinallrespectwithcover plate, grid plate, screws, MS box, etc withconnections as required.1 Nos RJ 45 Data Outlet |
| 486 | Supply,Installation,TestingandCommissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan withBrushLessDirectCurrent(BLDC)Motor, class of insulation: B, 3 Nosblades,30cmlongdownrod,2Noscanopies, shacklekit,safetyrope,copperwinding,Power Factor not less than 0.9, Service Value (CMM/W) minimum6.85,Airdeliveryminimum215CMM, 350 RPM (tolerance as per IS : 374-2019),THDlessthan10%,remoteorelectronic regulator unit for speed control and all remaining accessoriesincludingsafetypin,nutbolts, washers, temperaturerise=75degreeC(max.),insulationresistance more than 2 mega ohm, suitable for 230 V, 50 Hz, singlephaseACSupply,earthingetc.complete as required.1200 mm sweep |
| 487 | Supply of AC230/250 volts, 50 HZ exhaust fansincludingproviding nuts,bolts,mountingframe and other accessories etc.Complete300 mm sweep 900 rpm |
| 488 | Supply,installation, testing and commissioning ofMainDistribution Boardsuitableforupto 125ampFPMCCBincomerandsingle/three phaseoutgoingMCB\"s,IP43protection,double metal door, factory fabricated, wall mounting type insurface/recess,powdercoated,415V/200 amp copper Bus Bar, earth and neutral bar, removableglandplates,cableglandsincluding connection with outgoing feeders completeinall respect. DB\"s shall be original factory fabricated of approvedmake.Theratesshallbeexcludingall incoming and outgoing circuit breakers.8 Way TPN |
| 489 | ProvidingandfixingoffollowingratingFourpole MCCB\"sattheincomerofMain/subdistribution boardswith connectionsetc.completeasrequired.100 Amp FP MCCB(16 KA) |
| 490 | Supplying, fixing, connecting, testing and commissioning of followingrating, ISI marked (IS 8828) 240 / 415 volts, 10 KA, Miniature Circuit Breaker(MCB) ofsingle/double/three/ four polesintheexistingMCBDBorinexistingMS enclosure complete in all respects25 Amp. TP MCB |
| 491 | 40 Amp.TP MCB |
| 492 | Supply, installation, testing and commissioning of electrical pane, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection. Thepanelsheetstructureshallundergo seventank pre-treatmentprocess beforepainting. The sheet steel shall be all of 2.2mm thick CRCA sheet.All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers.The panel height shall not exceed 2200mmandthemaximumoperatingheightforany switchgear shall not be more than 1700mm.The panel shallbeprovidedwithminimum75mmbasechannel frame fabricated from ISMC sections.All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable. Continuousearthbusshallrunalroundthe panel with earthingstudsprovidedatminimum2places. The control wiring shall be carried out with minimum1.5/2.5 sqmm copper wires and adequatenumberofNO/NC,potentialfreecontacts incorporated for remote operation of the starters. Propersizedcableterminationglandplatesshallbe provided oncable alleys and knockouts for same shall beprovidedduringfabricationstage itself. The panel shallbeprovidedwithathermostaticallycontrolled heatingarrangement(200W)totakecareofhigh humidity conditions.A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel.Panel shall be so designed at to have minimum 20% spare feeders/space.Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement. All cable terminations shall be from top. The complete panel shall be fuse less type,for control circuits 2A/6A MCB\"s to be used. Allbusbarsshallbeofaluminium,electrolyticgrade only. Maximumdesigndensityshallnotexceed1 Amps/Sqmm. Allbusbarsshallbeinsulatedwith colouredheatshrinkablePVCsleeved. Allbusbar supports shall be non hygroscopic DMC/SMC supports. Thepanelshallbemanufacturedinconformanceto requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. The minimum clearances between bus bars shall be as follows : Phase to phase - minimum 20mm Phase to neutral-minimum 15mm Main L.T. Panel -G.F. Incoming : One (1) No 300Amp. 4 pole 1 NO. Metering : One(1)No.(0-500V)96x96Sqmmvoltmeterwith control fuse & selector switch. One(1)No.(0-300A)96x96SqmmCToperated Ammeter with selector switch, CTs etc. One (1) Set of Phase Indication Lamp. Bus Bar : One (1) No. 300 Amp. TPN aluminimum bus bar of suitable length. Outgoing : Phase indication lamps on nos outgoing to be provided. 100 Amps TPN-1No. OR outgoing as per site requirment |
| 493 | ProvidingandLayingunplastisizedrigidPVCpipe conformingtoIS:13592typeAincludingjointing, cutting andmakinggoodthewalls&floorsasper requirement.150mm |
| 494 | PLUMBING WORKSProvidingandfixingwhitevitreouschina extended wall mounting water closet of size 780x370x690mmofapprovedshape includingproviding&fixingwhitevitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4litre/8litres),includingseatcover,and cisternfittings,nuts,boltsandgasketetccomplete. |
| 495 | Providing & fixing white vitreous china wash basin with C.I. brackets painted white,15mmC.P.brasspillartaps,C.P.brass chainwithrubberplug,32mmC.P.brass waste of standerd pattern including cutting & making good the walls wherever required.a)White Vitreous China Wash basin size 630x450mmwithapairof15mmC.P.brass pillar taps |
| 496 | ProvidingandfixingP.V.C.wastepipefor sinkorwashbasinincludingP.V.C.wastefittings complete. Semi rigid pipe32 mm dia |
| 497 | Providingandfixing600x450mmbevelled edgemirrorofsuperiorglass(ofapproved quality) complete with 6mm thick hard board groundfixedtowoodencleatswithC.P.brass screws and washers complete. |
| 498 | Providingandfixingwhitevitreouschina flat back half stall urinal of size 580*380*350mm with white PVC automatic flushingcistern,withfittings,standardsizeC.P. brass flush pipe, spreaders with unions andclamps(allinD.P.brass)withwaste fitting as per IS : 2556, C.I. trap with outlet gratingandothercouplingsinC.P.brass including painting of fittings and cutting and makinggoodthewallsandfloorswhereverrequired:RangeofTwohalfstallurinalswith5litre PV.C. automatic flushing cistern. |
| 499 | Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitionsbycuttingachaseofappropriate widthwithchasecutterandembeddingthe stone in the chase withepoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size)asperdirectionofEngineer-in-chargeand finished smooth.Granite Stone of approved shade |
| 500 | CP Brass fittingsProviding and fixing unplasticised PVC connection pipe with brass unions45 cm length15 mm nominal bore |
| 501 | Providingandfixing C.P.brass bibcock of approved quality conforming to IS:8931a) 15 mm nominal bore |
| 502 | ProvidingandfixingC.P.brasslongbody bibcockofapprovedquality conformingto IS standards andweighing not less than 690gms.a) 15 mm nominal bore |
| 503 | ProvidingandfixingC.P.brassanglevalve for basin mixer and gyser points of approved quality conforming to IS:8931a) 15 mm nominal bore |
| 504 | Providing and fixing unplasticised-PVC pipe clipsofapproveddesigntounplasticised- PVC pipes by means of 50x50x50 mm hard woodplugs,screwedwithMSscrewsof required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarsesand)andmakinggoodthewall etc.complete.110mm |
| 505 | 90mm |
| 506 | Providingandlayingcementconcrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size)aroundP.V.CSoilandwastepipeincludingbed concrete as per standard design(embedded in the flooring / ground)110 mm dia |
| 507 | 90 mm dia |
| 508 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conformingtoIS:13592TypeAincluding jointingwithsealringconformingtoIS: 5382leaving10mmgapforthermalexpansion.110 mm |
| 509 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVCrainwaterpipesconformingto IS:13592 TypeAincludingjointingwith seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.Bend 87.5 degree110 mm Bend |
| 510 | Shoe (Plain)110 mm Shoe |
| 511 | Providingandfixingtotheinletmouthof rain water pipe cast iron grating 15 cm diameterandweighingnotlessthan440grams. |
| 512 | Providing and fixing unplasticised-PVC pipe clipsofapproveddesigntounplasticised- PVC rain water pipes by means of 50x50x50 mmhard wood plugs,screwed withMS screwsofrequiredlengthincludingcutting brickworkandfixingincementmortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 513 | Providingandfixing15cm wide45cm over all semi circular plain G.S. sheet gutter with ironbrackets40x3mmsize,bolts,nutsand washers etc. including making necessary connections with rain water pipes complete.0.80mm thick with zinc coating not less than275 gm/m2 |
| 514 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4(1cement:2coarsesand:4graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,roundingtheedgesand making and finishing the outlet complete. |
| 515 | ProvidingandfixingChlorinatedPolyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply includingallCPVCplain&brassthreaded fittingsi/cfixingthepipewithclampsat 1.00mspacing. Thisincludesjointingof pipes & fittings with one step CPVC solvent cementandthecostofcuttingchasesand making good thesame includingtestiang of joints complete as per directionof Engineerin Charge.Concealed work including cutting chases andmaking good the walls etc.20mm dia nominal outer dia pipes |
| 516 | 25mm dia nominal outer dia pipes |
| 517 | 32mm dia nominal outer dia pipes |
| 518 | Providingandfixinggunmetalgatevalvewith wheel of approved quality.25mm dia nominal bore |
| 519 | 32mm dia nominal bore |
| 520 | 40mm dia nominal bore |
| 521 | Providing and placing on terrace (at all floor levels)polyethylenewaterstoragetankISI: 12701markedindicatingtheBISLicense No.withcoverandsuitablelocking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent havingvalid ISI license]. Capcity in Per Liters |
| 522 | Providing and placing on terrace (at all floor levels)polyethylenewaterstoragetankISI: 12701markedindicatingtheBISLicense No.withcoverandsuitablelocking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent havingvalid ISI license]. Capcity in Per Liters Pipes,cablesetc.exceeding80mmdiabutnot exceeding 300mm. |
| 523 | Providing,layingandjointingglazed stonewarepipes grade\"A\" withstiff mixture of cement mortar in the proportion of 1:1 (1 cement:1finesand)includingtestingof joints etc. complete. 100mm diameter |
| 524 | Providing and laying cement concrete 1:5:10 (1cement:5coarsesand:10gradedstone aggregate 40mm nominal size) all roundS.W.pipesincludingbedconcreteasper 100mm dia SW pipe |
| 525 | ProvidingandlayingNon pressure NP2 class(lightduty)RCCpipewithcollars jointed withstiffmixtureofcement mortar intheproportionof1:2(1cement:2fine sand ) includingtestingof joints etc. 150 mm.dia. RCCPipes |
| 526 | Providing and laying cement concrete 1:5:10 (1cement:5coarsesand:10gradedstone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design150 mm.dia. RCCPipes |
| 527 | Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating,brickmasonrychamberwithwater tight C.I. cover with frame of 300 x300 mm size(inside)theweightofcovertobenot lessthan4.50kgandframetobenotless than 2.70 kg as per standard design150 x 100 mm size P type With Sewer bricks conforming to IS : 4885 |
| 528 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand)RCCtopslabwith1:2:4mix(1cement:2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1cement:4coarsesand:8gradedstone aggregate40mmnominalsize)inside plastering12mmthickwithcementmortar 1:3(1cement:3coarsesand)finishedwith floatingcoatfoneatcementandmaking channels in cement concrete 1:2:4 (1 cement:2coarsesand:4gradedstoneaggregate 20mmnminalsize)finishedwithafloating coat of neat cement complete as per standard design.Inside size 90x80cms and 45cms deep includingCIcoverwithframe(lightduty) 455x610mminternaldiamensionstotal weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight offrame 15kg). With FPS bricks of class designation 75(i) For Sewer Line Extra for depth for manholes: |
| 529 | Size 90X80 cm with FPS bricks (class I ). |
| 530 | Providing M.S. foot rests including fixing in manholes with20x20x10 cmcement concreteblocks1:3:6(1 cement:3coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar |
| 531 | Providing and fixing on wall face unplasticised Rigid PVC soil and waste water pipes conforming to IS : 13592 Type B including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes.a) 110mm dia P.V.C. pipe |
| 532 | b) 90mm dia P.V.C. pipe |
| 533 | Providing & fixing UPVC Floor trap of self cleansingdesign withCPJali completein allrespects.(Make:Supreme/Finolex/Prince)P-Trap type Floor Trap 110 x 110mm |
| 534 | Providing and fixingterminal guard. a) 110mm |
| 535 | b) 90mm |
| 536 | Providing and fixing on wall face unplasticised-PVCmoulded fittings/accessories for unplasticised Rigid PVCpipes includingjointingwithseal ring leaving 10 mm gap for thermal expansion.110mm bend |
| 537 | 90 mm bend |
| 538 | Coupler 110mm |
| 539 | 90mm |
| 540 | Single tee with door 90x90x90 mm |
| 541 | 110x110x110 mm |
| 542 | Providing & fixing Towel Rail 300mm Long For Wash Basin Area |
| 543 | Providing & fixing Soap Dispenser with MetallicbottleJAQUARACN-CHR-1137N |
| 544 | Providing&fixingBottleTrap(With InternalPartition)32mmSizeWith250mm &190mmLongWallConnectionPipes& Wall Flange JAQUAR ALD-CHR-769 |
| 545 | ProvidingandfixingHandShower(Health Faucet) with 8mm Dia, 1 Meter Long FlexibleTube&WallHook(forE.W.C.) JAQUAR ALD-CHR-573 |
| 546 | ProvidingandfixingC.P.brassTwo-way anglevalveforEWCpoints&forfixing AblutionHealthFauctofapprovedquality conforming to15 mm nominal bore |
| 547 | Providing and fixing clean out plug 110 mm dia. |
| 548 | TUBE WELL AND INSTALLATION OF SUBMERSIBLE PUMP (90 M. DEPTH)Boring/drillingborewellofrequireddiaforcasing/ strainer pipe,bysuitablemethodprescribedinIS:2800(partI), includingcollectingsamplesfrom differentstrata,preparing and submitting strata chart/ bore log, including hire & runningchargesofallequipments,tools,plants& machineries required for the job, all complete as per direction ofEngineer-in-charge,upto90metredepthbelowgroundlevel.300 mm dia |
| 549 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessoriesetc.all complete,for all depths, asper directionof Engineer -in-charge.100 mm nominal size dia |
| 550 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS)pipeswithribs,conformingtoIS:12818,including hire & labour charges, fittings & accessories etc. allcomplete,foralldepths,asperdirectionofEngineer-in-100 mm nominal size dia |
| 551 | Gravelpackingintubewellconstructioninaccordancewith IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, allcomplete as per direction of Engineer-in-charge. |
| 552 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable wateryield without sand content (beyond permissible limit)withrequiredcapacityaircompressor,runningthe compressorforrequiredtimetillwellisfullydeveloped, measuringyieldofwellby“V”notchmethodoranyother approved method, measuring static level & draw down etc. by stepdraw down method, collectingwater samples& getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and directionof Engineer-in-charge. |
| 553 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of :100 mm dia |
| 554 | Providing and fixing M.S. clamp of required dia to the top of casing/housingpipeoftubewellasperIS:2800(partI), includingnecessarybolts&nutsofrequiredsizecomplete.100 mm clamp. |
| 555 | Providing and fixing Bail plug/ Bottom plug ofrequired dia tothebottomofpipeassemblyoftubewellasperIS:2800(part I). 100 mm dia. |
| 556 | SupplyofsubmersiblepumpofmakeKSB2.0 HPwithcontrol panel, support wire etc. complete. |
| 557 | Providing2corePVCinsulatedsubmersibblecablefrompump panel to submersible pump |
| 558 | ProvidingandfixingG.I.pipescompletewithG.I.fittingsincluding trenching and refilling etc. 32 mm dia nominal bore |
| 559 | Providing and fixing gun metal gate valve with C.I. wheel ofapprovedquality (screwed end) |
| 560 | Supply of 100mm dia Johnson screen. |
| 561 | Servant RoomEarth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-incharge.All kinds of soil |
| 562 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 563 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M25 grade with minimum cementcontent of 330 kg /cum |
| 564 | All works above plinth level upto floor V level, As in item 3 but for the lighter beams i.e.having spans upto 6 m. (Using 1:1.5:3 Mix concrete) |
| 565 | All works above plinth level upto floor V level, As in item 3 above but forslabs (Using 1:1.5:3 Mix concrete) |
| 566 | All works upto plinth level, As in item 3 but for the Footing (Using 1:1.5:3 Mix concrete) |
| 567 | All works above plinth level upto floor V level, As in item 3 but for the Column(Using 1:1.5:3 Mix concrete) |
| 568 | Reinforcement for RCC work including straightening, cutting,bending, placing in position complete. -Thermo-Mechanically Treated |
| 569 | Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete |
| 570 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc |
| 571 | Diluting and injecting chemical emulsion for POST- CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 572 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 573 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse |
| 574 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse |
| 575 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hingeswith necessary screws |
| 576 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Sal wood |
| 577 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 578 | Providing and fixing bright finished brass nos butt nos with necessary screws etc. complete125x85x5.5mm(heavy type) |
| 579 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :250x10 mm |
| 580 | Providing and fixing bright finished brass door latch with necessary screws etc. complete.300x16x5 mm |
| 581 | Providing and fixing bright finished brass handles with screws etc. complete.125 mm |
| 582 | Providing and fixing bright finished brass hangging type floor door stoper with necessary screws etc. compelte. |
| 583 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) |
| 584 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) |
| 585 | 12 mm cement plaster 1:3( 1 cement: 3 coarse sand) finished with a floating coat of near cement |
| 586 | Add for plaster drip course/ groove in plastered surface or moulding toR.C.C. projections. |
| 587 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 588 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shadeArea of slab over 0.50 sqm |
| 589 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/ 10 sqm) over and including priming |
| 590 | Finishing with Deluxe Multi surface paint system for interiors and exteriorsusing Primer as per manufacturers specifications :Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.80 ltr/10 sqm of approved brand and manufacture |
| 591 | Wall painting with acrylic emulsion paint, having VOC (Volatile OrganicCompound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to |
| 592 | French spirit polishing : Two or more coats on new works including a coat ofwood filler |
| 593 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured |
| 594 | Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete. |
| 595 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass |
| 596 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and |
| 597 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access |
| 598 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 599 | Servant Room ELECTRICALINSTALLATIONSWIRING POINTS AND SUBMAINSPoint wiring in PVC ConduitWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed mediumclass PVC conduit, with modularswitch,modularplate,suitableGIboxandearthingthe point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 600 | Power plug wiring in PVC conduit (2 x 4 sqmm.) :-Wiring for light/ power plug with 2X4 sq. mm FRLS PVCinsulatedcopperconductorsinglecorecableinsurface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulatedcopperconductorsinglecorecableforloopearthingas required. |
| 601 | Circuit / Sub main wiring in PVC conduit :-Wiringforcircuit/submainwiringalongwithearthwirewiththe followingsizesofFRLSPVCinsulatedcopperconductor,single corecableinsurface/recessedmediumclassPVCconduitas2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. Earth wire |
| 602 | 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire |
| 603 | 4 x 6 sq.mm. + 2 x 6 sq.mm. Earth wire |
| 604 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 605 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 606 | SupplyingandfixingoffollowingsizesofmediumclassPVC conduitalongwithaccessoriesinsurface/recessincludingcutting the wall and making good the same in case of recessed conduit as20 mm. |
| 607 | 25 mm. |
| 608 | 32 mm. |
| 609 | S/F light plug point modular type accessories :-Supplying andfixing suitable size GI boxwith modularplate and coverinfrontonsurfaceorinrecess,includingprovidingand fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required |
| 610 | S/F power plug point modular type accessories :-Supplying andfixing suitable size GI boxwith modularplate and coverinfrontonsurfaceorinrecess,includingprovidingand fixing6pin5/6&15/16Amodularsocketoutletand15/16A modular switch, connections etc. as required. |
| 611 | S/F modular type electronic fan regulator :-Supplyingandfixingtwomodulesteppedtypeelectronicfan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 612 | S/F modular type blanking plate :-Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 613 | S/F MODULAR BOXES, BASE & COVER PLATE :-Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular switches inrecessetc as required1 or 2 Module (75 mm x 75 mm) |
| 614 | DISTRIBUTIONBOARDS,MCB\"s, MCCB\"sANDSFU\"sSupplying and fixing following way, horizontal type three pole and neutral,sheetsteel,MCBdistributionboard,415V,onsurface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,dinbar,interconnections,powderpaintedincludingearthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door, horizontal type |
| 615 | 6 way (4 + 18), Double door, horizontal type |
| 616 | Supplying andfixing 5A to32A rating, 240/415V, 10kA, \"C\" curve,miniaturecircuit breakersuitableforinductive loadof followingpolesintheexistingMCBDBcompletewith connections, testing and commissioning etc. as required single pole |
| 617 | Supplying and fixing following rating, four pole, 415 V, isolator in theexistingMCBDBcompletewithconnections,testingand commissioning etc. as required40 amps. |
| 618 | 63 amps. |
| 619 | Supplying&fixingsinglepole,blankingplateintheexisting MCBDBcomplete etc. as required. |
| 620 | Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug topalongwith20A\"C\"curve,TPMCB,insheetsteelenclosure,on surface or in recess, with chained metal cover for the socket out let andcomplete with connections, testing and commissioning etc. as required. |
| 621 | G.I.EARTHINGEarthingwithG.I.earthplate600mm X600mm X6mm thick including accessories, and providing masonry enclosure with cover platehavinglockingarrangementandwateringpipeof2.7metre long etc. with charcoal/ coke and salt as required. |
| 622 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below groundasstripearthelectrode,includingconnection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be donebyoverlappingandwith2setsofG.I.nutbolt&spring washer spaced at 50mm) |
| 623 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 624 | ERECTIONOFLIGHTINGFIXTURESANDFANSInstallation,testingandcommissioningofceilingfan,including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mmFRLSPVCinsulated,copperconductor,singlecorecable, includingprovidingandfixingphenoliclaminatedsheetcoveron the fan box etc. as required. |
| 625 | Supply and fixing of LED Tube Light with batten suitable for up to1X22wattLEDtubelightfittingincludingtubeonSurface complete in all respect. CAT- AAA |
| 626 | Supply and fixing of 12 Watt to 15 Watt indoor Recess mounting LEDSquare Fittingfor ArmstrongCeiling havingPowder coated diecastaluminiumhousingwithextendedheatsink,diffuserof Polycarbonate meterial and driver set complete in all respect. CAT-AAA |
| 627 | Supplyandfixingofrecess/Surface/Pendentmountinground6 Watt8WattLEDDownLighterhavingPowdercoateddiecast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA |
| 628 | Supplyandfixingofrecessmountinground15to18WattLED DownLighterhavingPowdercoateddiecastaluminiumhousing withheatsink,diffuser/Reflectoranddriversetcompleteinall respect. CAT- AAA |
| 629 | PART (B) -- NON SCHEDULED ITEMS (AS PER MARKET RATES)Supply,Installation,Testingand Commissioningof 1200mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)Motor,classofinsulation:B,3Nosblades,30cm long down rod, 2 Nos canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum6.85, Air deliveryminimum215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speedcontrolandallremainingaccessoriesincludingsafetypin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.1200 mm sweep |
| 630 | Providing and fixing of following rating Four poleMCCB\"s at the incomerofMain/subdistributionboardswith connectionsetc. complete as required.100 Amp FP MCCB(16 KA) |
| 631 | Supplying, fixing, connecting, testing and commissioning of following rating,ISImarked(IS8828)240/415volts,10KA, MiniatureCircuitBreaker(MCB) ofsingle/double/three / fourpolesintheexistingMCBDBorinexistingMSenclosure complete in all respects.25 Amp. TP MCB |
| 632 | GUARD ROOMEarth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-incharge.All kinds of soil |
| 633 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 634 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M25 grade with minimum cementcontent of 330 kg /cum |
| 635 | All works above plinth level upto floor V level, As in item 3 but for the lighter beams i.e.having spans upto 6 m. (Using 1:1.5:3 Mix concrete) |
| 636 | All works above plinth level upto floor V level, As in item 3 above but forslabs (Using 1:1.5:3 Mix concrete) |
| 637 | All works upto plinth level, As in item 3 but for the Footing (Using 1:1.5:3 Mix concrete) |
| 638 | All works above plinth level upto floor V level, As in item 3 but for the Column(Using 1:1.5:3 Mix concrete) |
| 639 | Reinforcement for RCC work including straightening, cutting, bending, placing in position complete. -Thermo-Mechanically |
| 640 | Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete |
| 641 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc |
| 642 | Diluting and injecting chemical emulsion for POST- CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 643 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 644 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse |
| 645 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse |
| 646 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hingeswith necessary screws |
| 647 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Sal wood |
| 648 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 649 | Providing and fixing bright finished brass nos butt nos with necessary screws etc. complete125x85x5.5mm(heavy type) |
| 650 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :250x10 mm |
| 651 | Providing and fixing bright finished brass door latch with necessary screws etc. complete.300x16x5 mm |
| 652 | Providing and fixing bright finished brass handles with screws etc. complete.125 mm |
| 653 | Providing and fixing bright finished brass hangging type floor door stoper with necessary screws etc. compelte. |
| 654 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) |
| 655 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) |
| 656 | 12 mm cement plaster 1:3( 1 cement: 3 coarse sand) finished with a floating coat of near cement |
| 657 | Add for plaster drip course/ groove in plastered surface or moulding toR.C.C. projections. |
| 658 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 659 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with whitecement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shadeArea of slab over 0.50 sqm |
| 660 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/ 10 sqm) over and including priming |
| 661 | Finishing with Deluxe Multi surface paint system for interiors and exteriorsusing Primer as per manufacturers specifications :Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.80 ltr/10 sqm of approved brand and manufacture |
| 662 | Wall painting with acrylic emulsion paint, having VOC (Volatile OrganicCompound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to |
| 663 | French spirit polishing : Two or more coats on new works including a coat ofwood filler |
| 664 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured |
| 665 | Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete. |
| 666 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for |
| 667 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers |
| 668 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and |
| 669 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and |
| 670 | Gaurd Room ELECTRICALINSTALLATIONSWIRING POINTS AND SUBMAINSPoint wiring in PVC ConduitWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed mediumclass PVC conduit, with modularswitch,modularplate,suitableGIboxandearthingthe point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 671 | Power plug wiring in PVC conduit (2 x 4 sqmm.) :-Wiring for light/ power plug with 2X4 sq. mm FRLS PVCinsulatedcopperconductorsinglecorecableinsurface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulatedcopperconductorsinglecorecableforloopearthingas required. |
| 672 | Circuit / Sub main wiring in PVC conduit :-Wiringforcircuit/submainwiringalongwithearthwirewiththe followingsizesofFRLSPVCinsulatedcopperconductor,single corecableinsurface/recessedmediumclassPVCconduitas2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. Earth wire |
| 673 | 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire |
| 674 | 4 x 6 sq.mm. + 2 x 6 sq.mm. Earth wire |
| 675 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 676 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 677 | SupplyingandfixingoffollowingsizesofmediumclassPVC conduitalongwithaccessoriesinsurface/recessincludingcutting the wall and making good the same in case of recessed conduit as20 mm. |
| 678 | 25 mm. |
| 679 | 32 mm. |
| 680 | S/F light plug point modular type accessories :-Supplying andfixing suitable size GI boxwith modularplate and coverinfrontonsurfaceorinrecess,includingprovidingand fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required |
| 681 | S/F power plug point modular type accessories :-Supplying andfixing suitable size GI boxwith modularplate and coverinfrontonsurfaceorinrecess,includingprovidingand fixing6pin5/6&15/16Amodularsocketoutletand15/16A modular switch, connections etc. as required. |
| 682 | S/F modular type electronic fan regulator :-Supplyingandfixingtwomodulesteppedtypeelectronicfan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 683 | S/F modular type blanking plate :-Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 684 | S/F MODULAR BOXES, BASE & COVER PLATE :-Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular switches inrecessetc as required1 or 2 Module (75 mm x 75 mm) |
| 685 | DISTRIBUTIONBOARDS,MCB\"s, MCCB\"sANDSFU\"sSupplying and fixing following way, horizontal type three pole and neutral,sheetsteel,MCBdistributionboard,415V,onsurface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,dinbar,interconnections,powderpaintedincludingearthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door, horizontal type |
| 686 | 6 way (4 + 18), Double door, horizontal type |
| 687 | Supplying andfixing 5A to32A rating, 240/415V, 10kA, \"C\" curve,miniaturecircuit breakersuitableforinductive loadof followingpolesintheexistingMCBDBcompletewith connections, testing and commissioning etc. as required single pole |
| 688 | Supplying and fixing following rating, four pole, 415 V, isolator in theexistingMCBDBcompletewithconnections,testingand commissioning etc. as required40 amps. |
| 689 | 63 amps. |
| 690 | Supplying&fixingsinglepole,blankingplateintheexisting MCBDBcomplete etc. as required. |
| 691 | Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug topalongwith20A\"C\"curve,TPMCB,insheetsteelenclosure,on surface or in recess, with chained metal cover for the socket out let andcomplete with connections, testing and commissioning etc. as required. |
| 692 | G.I.EARTHINGEarthingwithG.I.earthplate600mm X600mm X6mm thick including accessories, and providing masonry enclosure with cover platehavinglockingarrangementandwateringpipeof2.7metre long etc. with charcoal/ coke and salt as required. |
| 693 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below groundasstripearthelectrode,includingconnection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be donebyoverlappingandwith2setsofG.I.nutbolt&spring washer spaced at 50mm) |
| 694 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 695 | ERECTIONOFLIGHTINGFIXTURESANDFANSInstallation,testingandcommissioningofceilingfan,including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mmFRLSPVCinsulated,copperconductor,singlecorecable, includingprovidingandfixingphenoliclaminatedsheetcoveron the fan box etc. as required. |
| 696 | Supply and fixing of LED Tube Light with batten suitable for up to1X22wattLEDtubelightfittingincludingtubeonSurface complete in all respect. CAT- AAA |
| 697 | Supply and fixing of 12 Watt to 15 Watt indoor Recess mounting LEDSquare Fittingfor ArmstrongCeiling havingPowder coated diecastaluminiumhousingwithextendedheatsink,diffuserof Polycarbonate meterial and driver set complete in all respect. CAT-AAA |
| 698 | Supplyandfixingofrecess/Surface/Pendentmountinground6 Watt8WattLEDDownLighterhavingPowdercoateddiecast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA |
| 699 | Supplyandfixingofrecessmountinground15to18WattLED DownLighterhavingPowdercoateddiecastaluminiumhousing withheatsink,diffuser/Reflectoranddriversetcompleteinall respect. CAT- AAA |
| 700 | PART (B) -- NON SCHEDULED ITEMS (AS PER MARKET RATES)Supply,Installation,Testingand Commissioningof 1200mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)Motor,classofinsulation:B,3Nosblades,30cm long down rod, 2 Nos canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum6.85, Air deliveryminimum215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speedcontrolandallremainingaccessoriesincludingsafetypin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.1200 mm sweep |
| 701 | Providing and fixing of following rating Four poleMCCB\"s at the incomerofMain/subdistributionboardswith connectionsetc. complete as required.100 Amp FP MCCB(16 KA) |
| 702 | Supplying, fixing, connecting, testing and commissioning of following rating,ISImarked(IS8828)240/415volts,10KA, MiniatureCircuitBreaker(MCB) ofsingle/double/three / fourpolesintheexistingMCBDBorinexistingMSenclosure complete in all respects.25 Amp. TP MCB |
| 703 | UNDER GROUND WATER TANKEarth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil |
| 704 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement: 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derivedfrom natural sources) |
| 705 | Providing and laying in position speccific grade of reincorced cement concreteexcluding the cost of centering and shuttering - All work up to plinth level : 1:1.5:3(1 Cement : 1.5coarse sand:3 graded stone aggregatederived from natural sources |
| 706 | Reinfoced Cement Concrete work in walls (of any thickness ) including,pillasters buttresses plinth and string courses 1:1.5:3(1 Cement : 1.5coarse sand:3 graded stone aggregatederivedfrom natural sources |
| 707 | Reinfoced Cement Concrete work in beams, suspended floor 1:1.5:3(1 Cement : 1.5coarse sand:3 graded stone aggregatederived from natural sources |
| 708 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 709 | Centring &shuttering of walls (any thickness) including attaches pillasters , buttresses,plinth and string courses |
| 710 | Providing and fixing in position pre cast RCCMain holecover of required shapeand approved qualityRectangular shape 600x450mm internaldimesnions |
| 711 | Boundry Wall (Secretary Residence)Contsruction of Boundry wall as per drawing with all complete. As per direction of Engineer In Charge |
| 712 | EXTERNAL ELECTRIFICATION & LANDSCAPE LIGHTINGSupply & Fixingof’ 5mtr long Antique designed pole with castaluminium/ironbasewithgalvanized steelpipeand decorativetoppaintedwithprimerthenpaintedwithdull finished polyurethane paint fitted with MCB and connector withdecorativebracketsinglearmformountingof1nos drop down lantern with body made out ofspun aluminium and fitted with poly carbonate diffuser in 110W with built in surge protector and lumn output>110lmn/watt. Design as perArchitectincharge. (Make-Twinklelite/wipro/K Lite/ Luster) |
| 713 | Supplying Testing & Installation of Led Flood Light Luminaire50W PhilipsMakeModel-BVP140Led50 CW PSU WH/ Wipro/ Luster etc all complete of directionof engineer in charge. |
| 714 | Supplying Testing & Installation ofLed Flood Light Luminaire 100WV Philips Make Model- BVP 142 Led 100 CW PSU WH / Wipro/ Lusteretc all complete of direction of engineer in charge. |
| 715 | Supply and fixing of decorative16 Watt LEDbollard luminaire with driver set confirming to IP 65 protection complete in all respect. |
| 716 | Earthingwithcopperearthplate 600mm X600mm X 3 mmthickincludingaccessories,andprovidingmasonry enclosure with cover plate having locking arrangement and wateringpipeof2.7metrelongetc.withcharcoal/cokeand salt as required |
| 717 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 718 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metrebelowgroundasstripearthelectrode,including connection/terminatingwithnut,bolt,spring,washeretc. as required. (Jointing shall be done by overlapping and with 2 sets of brassn nut bolt & spring washer spaced at 50mm) |
| 719 | Supply and layingofaluminium conductorPVCinsulated armouredservedsheathedcables1100Voltsgradeata depth of 750 mm below ground level over a cushion of 75mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S.clampsetc.ofsuitablesizeorasdirectedby the Engineer-Incharge ,complete in all respect. The armouring ofthecableshallbeproperlyconnectedwiththeearth conductor by clamps etc.6.00 Sqmm 4 Core |
| 720 | 25.00 Sqmm 3.5 Core |
| 721 | 70.00 Sqmm 3.5 Core |
| 722 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect.40 A TPN |
| 723 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench,complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 724 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 725 | LANDSCAPE & HORTICULTUREProvidingandstackingofBottlepalmofht.270-300 cm bottom girth 40-50cm well developed in big HDPE bags as per diection of the officer-in-charge. |
| 726 | ProvidingandstackingofFicusbenjamina(green)of height150-165cm.,bushywithhealthybranchesand lush green foliage in big size HDPE bags as perdirection of the officer-in-charge. |
| 727 | Providing and stacking of Ficus bengalensis krishna of height 75-90 cm., multibranched in earthen pots of size 30 cm as per direction of the officer-in-charge |
| 728 | ProvidingandstackingofTectonagrandis(Teak)of height 150-165 cm. in big polybags of size 25 cm as perdirection of the officer-in-charge. |
| 729 | ProvidingandstackingofWashingtoniafilifeapalm stem ht. 90-105cm with6-7healthy leaveslushgreen leaveswelldevelopedinbigsizeHDPEBagsasperdirection of the officer-in-charge. |
| 730 | Providing and Displaying Sunflower hybrid well developed 15 to 20 cm ht. with fresh & healthy foliage at blooming stage in 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge. |
| 731 | Providing and Displaying Creeper Rose variety 3 to 4 healthy branch 60 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer-in-charge. |
| 732 | Providing and Displaying Standard Rose (H.T. variety) 3 to 4 healthy branch 90 cm and above ht. well developed with one and above flowers in 25 Earthen Pot, as per direction of the officer-in-charge. |
| 733 | Providing and Displaying Bamboo Buddha vally variety with umbrella shape having 120 to 135 ht. with fresh & healthyfoliagewelldevelopedin40cmCementpot multy branch,bushy asperdirectionoftheofficer-in- charge. |
| 734 | Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per directionof the officer-in-charge. |
| 735 | Providing and stacking of Plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. |
| 736 | Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushty shape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & asper direction of the officer-in-charge.. |
| 737 | Trenchinginordinarysoiluptorequireddepth including removal and stacking of serviceable materialsandthendisposingofasdirectedand spreadingearth&neatly levelling,breakingclods etc.andmakingthetrenchedareawithdesigned mounds,pathsandsittingspacesetc.toproper levelsbyfillingwithearthorearthmixedwith manureandproperlywateringcompleteworkin required topography as per drawing &specifications. |
| 738 | Supplying and stacking of good earth at site including royalty but including carriage1km (earth measusredinstackswillbereducedby20%for |
| 739 | Supplying andstacking atsitedumpmanure from approved source,includingcarriageupto1km (manure measured in stacks will be reduced by8%for payment) |
| 740 | Mixing earth and manure in specified proportion oras directed. |
| 741 | Rough dressing the trenched ground includingbreaking the clods. |
| 742 | Fine dressing the ground |
| 743 | Spreadingof mixedgoodearthandmanurein specified proportions as aboveand inrequiredthickness. |
| 744 | Uprooting weeds from the trenched area after 10 to15 days after flooding with water including disposal of uprooted vegetation. |
| 745 | Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness on existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface withlightrollermakethesurfacesmoothenand light watering the same, as per direction of officerin charge |
| 746 | Preparation of mounds of various size and shape by availableexcavated/suppliedearthinlayersnot exceeding 20 cm in depth, breaking clods, watering of nos layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge. |
| 747 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering |
| 748 | TREMIX PARKINGExcavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 749 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 750 | Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete. |
| 751 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 752 | Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete. |
| 753 | Mildsteel or ironinplainworksuchas reinforcedconcrete orreinforced ,brick work (when not includedin anover all rates )wrought to required shapeas necessary including bendingforproper completion of theworkand includingsupplyof steelitswastage bendhooksand authorised overlapping shallbe measured upto floor two level. |
| 754 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 755 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of jointsexcept at sharp curve shall not to more than 5mm), including making drainage opening whereverrequired complete etc. as per direction of Engineer- in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 756 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 757 | PATHWAYEarth workin excavation bymechanicalmeans (Hydraulicexcavator)/manualmeansoverareas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto1.5m,asdirectedbyEngineer-incharge.Allkinds of soil |
| 758 | Providing and laying in position cement concrete of specified grade excluding the cost ofcentering and shuttering-Allworkuptoplinthlevel:1:4:8(1 Cement:4coarsesand(zone-III)derivedfrom naturalsources:8gradedstoneaggregate40mmnominal size derived from natural sources) |
| 759 | Providing and laying factory made chamferededge CementConcretepaverblocksinfootpath,parks, lawns,drivewaysorlighttrafficparkingetc,of required strength, thickness & size/ shape, made by tablevibratorymethodusingPUmould,laidin requiredcolour&patternover50mmthick compacted bed of sand, compacting andproper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per requiredsizeandpattern,finishingandsweeping extra sand. complete all as per direction of Engineer in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 760 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in positiontotherequiredline,levelandcurvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves(thicknessofjointsexceptatsharpcurve shallnottomorethan5mm),includingmaking drainageopeningwhereverrequiredcompleteetc. asperdirectionofEngineer-in-charge(lengthof finished kerb edging shallbe measured for payment). (Precast C.C. kerb stone shall be approvedby Engineer-in-charge). |
| 761 | DrainEarth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil |
| 762 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominalsize) |
| 763 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cementcontent, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Concrete of M25 grade with minimum cement content of 330 kg /cum All works above plinth level upto floor V level |
| 764 | As in item 4 above but forslabs |
| 765 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-MechanicallyTreated bars |
| 766 | GATEProviding and fixing M.S. grills of required pattern in frames of windows / Gate etc. withM.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 767 | RAIN WATER HARVESTING PITSEarthworkinexcavationbymechanical means (Hydraulic excavator) / manual meansinfoundationtrenchesordrains (notexceeding1.5minwidthor10sqm onplan),includingdressingofsidesand ramming of bottoms, lift upto 1.5 m, includinggettingouttheexcavatedsoil anddisposalofsurplusexcavatedsoilas directed, within a lead of 50 m.All kinds of soil |
| 768 | Brick work with common burnt clay F.P.S. (nonmodular)bricksofclassdesignation7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cementmortar1:6(1cement:6coarsesand) |
| 769 | CEMENTPLASTERWITHAFLOATINGCOAT OF NEAT CEMENT12mmcementplasterfinished withafloating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand) |
| 770 | Reinforcedcementconcreteworkin beams, suspended floors, roofs having slopeupto15°landings,balconies, shelves,chajjas,lintels,bands,plain window sills, staircases and spiral stair casesaboveplinthleveluptofloorfive level, excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3(1cement:1.5coarsesand (zone-III):3gradedstoneaggregate20 mm nominal size). RCC(1cement:1.5corasesand:3stoneaggregate) |
| 771 | FORM WORKCenteringandshutteringincluding strutting, propping etc.and removal of form for all heights :Centeringandshutteringincluding strutting, propping etc.and removal of form for all heights : Suspended floors, roofs, landings,balconies and access platform |
| 772 | STEEL REINFORCEMENTSteel reinforcement for R.C.C.work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. Hot rolled deformed bars |
| 773 | Boring/drillingborewellofrequireddia forcasing/strainerpipe,bysuitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/borelog,includinghire&running charges of all equipments, tools,plants & machineriesrequiredforthejob,all completeasperdirectionofEngineer-in- charge,upto90metredepthbelow ground level.All types of soil300mm dia |
| 774 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM)pipeofrequireddia,conformingto IS: 12818, including required hire and labourcharges,fittings&accessoriesetc. allcomplete,foralldepths,asper direction of Engineer -in-charge.150 mm nominal size dia |
| 775 | Supplying, filling, spreading & leveling stonebouldersofsizerange5cmto20 cm,inrechargepit, inthe required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 776 | Supplying, filling, spreading & leveling gravelsofsizerange5mmto10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 777 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all completeasperdirectionofEngineer-incharge |
| 778 | Gravel packing in tubewell construction in accordancewithIS:4097,including providinggravelfine/medium/coarse,in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 779 | ProvidingandfixingM.S.clampof required dia to the top of casing/ housing pipeoftubewellasperIS:2800(partI), includingnecessarybolts&nutsof required size complete.150 mm clamp |
| 780 | Providing and fixing Bail plug/ Bottom plug of required dia to thebottomofpipeassemblyoftubewellas per IS:2800 (part I).150mm dia |
| 781 | Providing,fixinginpositionofISImarked UVstabilizedUPVCpipes forventing, Type-B as per IS : 13592 suitable for rubberringjointsforverticalpipesand solvent cement joints for horizontal pipes, includingallneccessaryspecialsand fittings (Make : Finalex/ Astral / Ashirwad) 75mmdia(WallThickness-3.2to3.8mm) |
| 782 | Providingandfixinginpositionpre-castR.C.C. manhole cover andframe of required shape and approved quality Rectangularshape600x450mminternaldimensions |
| 783 | Providingorangecoloursafetyfootrest of minimum 6 mm thick plastic encapsulatedasperIS:10910,on12mm dia. Steel bar conforming to IS:1786, having minimum cross section as 23mm x 25mmandoverallminimumlength263 mm and width as 165 mm with minimum112 mm space between protruded leg having 2 mm tread on top surface by ribbingorchequeringbesidesnecessary andadequatedanchoringprojectionson taillengthon138mmasperstandard drawingandsuitabletowithstandthe bendtestandchemicalresistancetestas per spaecifications and having manufacture\"spermanentidentification mark to be visible even after fixing, includingfixinginmanholeswith 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate20mmnominalsize)complete as per design. |
| 784 | DG SET, SOLER PLANT,CCTV AND VRV/VRF SYSTEM ACSupplying, installation, testing and commissioning of silent type DG sets, AMF panel, bus ducting/ cables from DG sets to. essential panel, synchronizing panel where réquired, DG set enclosure room sound insulation/ventilation/smoke exhaust as required, earthing of DG set system, control cabling, fuel tank/piping, DG set exhaust piping/ exhaust chimney as per CPCB norms, civil works connected with DG sets including foundation as required. |
| 785 | Supplying, installation, testing and commissioning of VRV/VRF system including indoor/outdoor units, piping, electrical power distribution/wiring, electrical panel, treated fresh air system etc. |
| 786 | Supplying, installation, testing and commissioning of grid interactive roof Top solar photo voltaic power generation system including space frame |
| 787 | Supplying, installation, testing and commissioning of IP based CCTV system for building security comprising of PTZ / fixed camera, cabling, recording, display system and hard ware software support - for indoors only {Rate applicable on total plinth area). |
| 788 | CE, CTP and CAO RSIDENCEBUILDING WORKEarth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil |
| 789 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating nos deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m |
| 790 | Diluting and injecting chemical emulsion for PRE- CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 791 | Supplying and filling in plinth with sand under floors,including watering, ramming, consolidating and dressing complete. |
| 792 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 793 | Providing centering & shuttering including strutting, propping etc. & removal of form including all materials, labour and T & P etc. required for proper completion of work all completeFoundation, Footing, base of columns and plinth beam in any shape and size upto plinth level. |
| 794 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 795 | Lintels, beams, plinth beams, girders, bressumers andcantilevers |
| 796 | Suspended floors, roofs, landings, balconies and accessplatform |
| 797 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cumAll works up to Plinth level. |
| 798 | All works AbovePlinth level & upto Floor V Level |
| 799 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D ormore. |
| 800 | Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement Mortar1:4 (1 cement : 4 coarse sand) |
| 801 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 802 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1cement :3 coarse sand) |
| 803 | 15 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) |
| 804 | 12 mm cement plaster of mix : 1:4 (1 cement:4 coarse sand) |
| 805 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) |
| 806 | Making grooves 10 to 12mmwidex 8mm deep in plasterof the wallor in ceiling vertically or horizontally as required. |
| 807 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall bepaid for separately).Second class teak wood |
| 808 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hingeswith necessary screws |
| 809 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugsscrews etc |
| 810 | Providing & fixingsystem Profile Aniodised Aluminium Window all complte as per direction of enginner in chargeFixed part |
| 811 | Providing & fixingsystem Profile Aniodised Aluminium Window all complte as per direction of enginner in chargeCasement window with top pin |
| 812 | Providing & fixingsystem Profile Aniodised Aluminium Window all complte as per direction of enginner in charge Slider 3T 3P Triple track (Tostom , Schuco) |
| 813 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). |
| 814 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand andmanufacture |
| 815 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacture\"s specifications including appropriate priming coat, preparationof surface, etc. complete. On steel work |
| 816 | French spirit polishing :Two or more coats on new worksincluding a coat of wood filler |
| 817 | Providing and applying plaster of paris putty of 2 mmthickness over plastered surface to prepare the surface even and smooth complete. |
| 818 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnablepriming coat with cement primer |
| 819 | Finishing walls with textured exterior paint of required shade: New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 820 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even andsmooth complete. |
| 821 | Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. (Make Hilti/ Fisher/Helifix)Frame anchor HRD-C 10x140 |
| 822 | Providing and fixing aluminium sliding door bolts, ISI marked anodised anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm |
| 823 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868 ) transparent or dyed to required colour or shade, withnecessary screws etc. complete : 200x10 mm |
| 824 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, withnecessary screws etc. complete : 125 mm |
| 825 | Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement..(40mm thickwith 20 mm nominal aggregate). |
| 826 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. IN : toilet Block |
| 827 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 828 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete Double charged Vitrified Tile Polish finish Size 1200x600mm |
| 829 | Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red Area of slab over 0.50 sqm |
| 830 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1cement : 4 coarse sand) : 25 mm thick |
| 831 | 25 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with Second classteak wood |
| 832 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 833 | Providingandlayingintegralcementbasedwaterproofing treatmentincludingpreparationofsurfaceasrequiredfor treatment ofroofs,balconies, terraces etcconsisting of followingoperations:a)Applyingaslurrycoatofneat cementusing2.75kg/sqmofcementadmixedwithwater proofing compound conforming to IS. 2645 and approved by Engineer-in-chargeovertheRCCslabincludingadjoining wallsupto300mmheightincludingcleaningthesurface beforetreatment.b)Layingbrickbatswithmortarusing broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with waterproofingcompoundconformingtoIS:2645and approvedby Engineer-in-chargeover20mmthicklayerof cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to requiredslope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) Aftertwodaysofpropercuringapplyingasecondcoatof cement slurryusing 2.75 kg/ sqm of cement admixed jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conformingto IS: |
| 834 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed fromM.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm nos having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm onboth sides of joint and two coats of primer suitable for board, all as per |
| 835 | Providing & Fixing of (Armstrong / USG Boral / Hunterdouglous) Soft Fibre Acoustical Suspended Ceiling System with Optra Beveled Tegular Edge Tiles With Armstrong Suprafine 15mm Exposed Grid. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9 - 1.0, Colour Black, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600x600x15mm, suitable for Green Building application, with Recycled content of 66% GW & 74% RW.The tile shall be laid on Armstrong Suprafine 32 with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 32mm& pull out strength of 100Kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system of Armstrong make. INSTALLATION: To comprise main runner spaced at 1200mm securely fixed to the structural soffit using Armstrong suspension system (specifications below) at 1200mm maximum. The First/Last Armstrong suspension system at the end of nos main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm to form 1200 x 600 mm module.Cut cross tees longer than 600mm require independentsupport. 600 x 600mm module to be formed by fitting 600mm long |
| 836 | Providing and laying Italian marble of 18 mm thickness (polished finish) over prepared screed/substrate with polymer-modified thin-set adhesive, jointing with matching grout, polishing, sealing, andfinishing, complete as per manufacturer’s specifications and Architect’sdirection. |
| 837 | Providing, supplying, and laying Stonex paving slabs / driveway stones over prepared base, with bedding, jointing, finishing, and all associated works, for vehicle traffic, complete as per drawings, manufacturer’s instructions, and Engineer‑in‑Charge directions |
| 838 | Providing and installing a fully modular, high-end kitchen setup including base units, wall units, tall units, and integrated accessories. The carcass shall be made of 18 mm BWP (Boiling Water Proof) grade plywood (IS 710), laminated internally with 1 mm white laminate and all edges sealed with matching PVC edge banding. Shutters shall be finished in high-gloss PU paint / acrylic laminate / veneer with PU polish or lacquered glass, mounted on soft-close hinges (Hettich/Blum), with drawers fitted with soft-close tandem channels. Lift-up systems shall be provided in overhead cabinets where applicable. Handle-less profile or designer handles shall be used as per the approved design.The countertop shall be made of premium 18–20 mm thick Quartz / Granite or large format porcelain slab with matching backsplash up to the overhead cabinets. A double bowl under-mount sink in stainlesssteel (Franke/Nirali/Blanco) with a designer pull-out faucet shall be provided. The under-sink cabinet shall have a waterproof base and built- in cleaning tray. Accessories include modular cutlery trays, bottle pull- outs, corner carousels or magic corners, pull-out pantry units, and dual- bin waste segregation systems. |
| 839 | Supplying, installing, testing, and commissioning of kitchen chimney of wall-mounted / island type as per layout, with suction capacity not less than [900–1200 m³/hr], auto-clean technology, stainless steel or glass finish, baffle filters / filterless, complete with ducting (PVC/Aluminium flexible), clamps, wall sleeve, exhaust cap, electrical connection, and all accessories for proper functioning, including making cut-outs in masonry/plywood for ducts and making good the same, all complete as per approved make, technical specifications, and instructions of the Engineer-in-Charge |
| 840 | High-Pressure Laminate (HPL) exterior façade includes supply and installation of weather-resistant HPL panels (typically 6-8mm thick) fixed on an aluminum or galvanized steel subframe. Panels are UV- stabilized, fire-rated, and come in various finishes. The scope covers mechanical fasteners, EPDM gaskets, sealants, and necessary support brackets, ensuring proper ventilation and thermal movement allowance. Rates generally range from ₹750 to ₹1,400 per sq. meter, including materials and labor, with a recommended 5-10% wastage. Final costs depend on panel brand, façade area, and site conditions. (Findermax or equiavlent ) |
| 841 | Material: Aluminum Composite Panel (typically 4mm thickness) Finish: PVDF or Polyester coated, weather and UV resistantSub-frame: Aluminum or GI framing with brackets and fasteners Typical Rate: ₹900 to ₹1,600 per sqm (including supply, fabrication, and installation)Includes: ACP panels, substructure, fixings, sealants, and labor Note: Rates vary depending on brand, panel thickness, coating type, and site conditions |
| 842 | Providing and fixing exterior-grade thin brick veneer tiles (approx. 2¼\" x 7⅝\", thickness ½\"–¾\"), of approved make, size, color, and texture, in [running bond / herringbone / stack bond] pattern, laid over prepared substrate with polymer-modified thin-set mortar or Type N/S cement mortar, including surface preparation, corner units, control joints, pointing, cleaning, and necessary scaffolding, all complete as per drawings, specifications, and instructions of the Engineer-in-Charge |
| 843 | Providing and fixing mica laminate finish (decorative high-pressure laminate) of approved make, shade, and thickness (typically 1.0 mm) on furniture surfaces / wall paneling / partitions / doors, etc., using approved synthetic resin adhesive (Fevicol SH or equivalent) over prepared surface (e.g., BWP grade plywood, MDF, blockboard), including edge finishing, trimming, cleaning, and all tools, adhesives, materials, labour and incidentals, complete in all respects as per drawings and instructions of the Engineer-in-Charge (Sylvan , Green ply, Austin ) |
| 844 | ELECTRICALINSTALLATIONSWIRING POINTS AND SUBMAINSPoint wiring in PVC ConduitWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copperconductorsinglecorecableinsurface/ recessedmediumclassPVCconduit,with modularswitch,modularplate,suitableGIbox and earthing the point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable etc.Group C |
| 845 | Power plug wiring in PVC conduit (2 x 4sqmm.) :-Wiringforlight/powerplugwith2X4sq.mm FRLS PVCinsulatedcopperconductorsinglecorecablein surface/ recessed medium class PVC conduit alongwith1No.4sq.mmFRLSPVCinsulated copper conductor single core cable for loopearthing as required. |
| 846 | Circuit / Sub main wiring in PVC conduit :-Wiringfor circuit/submain wiringalongwith earth wire with the following sizes of FRLS PVC insulatedcopperconductor,singlecorecablein surface/recessedmediumclass PVCconduit asrequired.2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. Earth wire |
| 847 | 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire |
| 848 | 4 x 6 sq.mm. + 2 x 6 sq.mm. Earth wire |
| 849 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 850 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 851 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessedconduit as required20 mm. |
| 852 | 25 mm. |
| 853 | 32 mm. |
| 854 | S/F light plug point modular type accessories :-SupplyingandfixingsuitablesizeGIboxwith modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modularsocketoutletand5/6Amodularswitch,connections etc. as required |
| 855 | S/F power plug point modular type accessories :-SupplyingandfixingsuitablesizeGIboxwith modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 856 | S/F modular type electronic fan regulator :-Supplyingandfixingtwomodulesteppedtype electronicfanregulatorontheexistingmodular plateswitchboxincludingconnectionsbutexcluding modular plate etc. as required. |
| 857 | S/F modular type blanking plate :-Supplyingandfixingmodularblankingplateon the existing modular plate & switch box excludingmodular plate as required. |
| 858 | TELEPHONE, TELEVISION AND DATA NETWORKTELEPHONE WIRING IN EXISTING CONDUIT :-Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmoredtelephonecableintheexisting surface/ recessed steel/ PVC conduit as required2 Pair |
| 859 | S/F MODULAR BOXES, BASE & COVER PLATE :-Supplyingandfixing followingsize /modules, GI boxalongwithmodularbase&coverplatefor modular switches inrecessetc as required1 or 2 Module (75 mm x 75 mm) |
| 860 | S/F MODULAR TYPE SWITCH / SOCKET :-Supplyingandfixingfollowingmodularswitch/ socket on the existing modular plate & switch box including connections but excluding modular plateetc as requiredTelephone Socket outlet |
| 861 | DISTRIBUTIONBOARDS,MCB\"s, MCCB\"sANDSFU\"sSupplying and fixing following way, horizontal type threepoleandneutral,sheetsteel,MCB distribution board, 415V,onsurface/recess, complete with tinned copper bus bar, neutral bus bar,earthbar,dinbar,interconnections,powder paintedincludingearthingetc.asrequired.(Butwithout MCB/RCCB/Isolator)4 way (4 + 12), Double door, horizontal type |
| 862 | 6 way (4 + 18), Double door, horizontal type |
| 863 | Supplying andfixing 5A to32 A rating, 240/415 V,10kA,\"C\"curve,miniaturecircuitbreaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as requiredsingle pole |
| 864 | Supplyingandfixingfollowingrating,fourpole, 415 V, isolator in the existing MCB DB complete with connections,testing andcommissioning etc.as required40 amps. |
| 865 | 63 amps. |
| 866 | Supplying& fixing singlepole, blankingplate in the existing MCBDBcomplete etc. as required. |
| 867 | Supplying and fixing 20 A, 415 V, TPN Industrial type socketoutlet, with 4 pole and earth, metal enclosed plug topalongwith 20 A \"C\" curve, TPMCB, in sheet steel enclosure,onsurfaceorinrecess,withchained metalcoverforthesocketoutletandcomplete with connections,testing andcommissioning etc.as required. |
| 868 | G.I.EARTHINGEarthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with coverplate having lockingarrangementandwateringpipeof2.7 metrelongetc.withcharcoal/cokeandsaltasrequired. |
| 869 | Supplying and laying 25 mm X 5 mm G.I strip at0.50 metre below ground as strip earth electrode, includingconnection/terminatingwithG.I.nut, bolt,spring,washeretc.asrequired.(Jointing shallbedonebyoverlappingandwith2setsofG.I. nut bolt & spring washer spaced at 50mm) |
| 870 | Providingandfixing25mmX 5mmG.I.strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 871 | ERECTIONOFLIGHTINGFIXTURESANDFANSInstallation,testingandcommissioningofceiling fan,includingwiringthedownrodsofstandard length(upto30cm)with1.5sq.mmFRLS PVC insulated,copperconductor,singlecorecable, includingprovidingandfixingphenoliclaminated sheet cover on the fan box etc. as required. |
| 872 | Installation of exhaust fan in the existing opening, includingmakinggoodthedamage,connection, testing, commissioning etc. as required. Upto 450mm sweep |
| 873 | SupplyandfixingofLEDTubeLightwithbatten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect.CAT- AAA |
| 874 | Supplyandfixingof12Wattto15Wattindoor RecessmountingLEDSquareFittingfor Armstrong Ceiling having Powder coated die cast aluminium housing with extended heat sink, diffuserofPolycarbonatemeterialanddriversetcomplete in all respect. CAT- AAA |
| 875 | Supplyandfixingofrecess/Surface/Pendent mounting round 6 Watt 8 Watt LED Down Lighter havingPowdercoateddiecastaluminium housingwithheatsink,diffuser/Reflectorand driver set complete in all respect. CAT- AAA |
| 876 | Supply and fixing of recess mounting round 15 to 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflectoranddriversetcompleteinallrespect. CAT- AAA |
| 877 | Supply and fixing of sqaure Light 40-60Watt LED DownLight(600x600)mmhavingPowder coated die cast aluminium housing with heat sink, diffuser/Reflectoranddriversetcompleteinallrespect. |
| 878 | Providing & Fixing of modular plate type white RJ 45CAT6Dataoutlet/informationoutletsETL verifiedtomeetorexceedTIA/EIAcategory6 requirements,universalwiringlabelpermittingto eitherT568AorT568B,ULlisted, forcomputer networking completeinallrespectwithcover plate, grid plate, screws, MS box, etc withconnections as required.1 Nos RJ 45 Data Outlet |
| 879 | Supply,Installation,TestingandCommissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan withBrushLessDirectCurrent(BLDC)Motor, class of insulation: B, 3 Nosblades,30cmlongdownrod,2Noscanopies, shacklekit,safetyrope,copperwinding,Power Factor not less than 0.9, Service Value (CMM/W) minimum6.85,Airdeliveryminimum215CMM, 350 RPM (tolerance as per IS : 374-2019),THDlessthan10%,remoteorelectronic regulator unit for speed control and all remaining accessoriesincludingsafetypin,nutbolts, washers, temperaturerise=75degreeC(max.),insulationresistance more than 2 mega ohm, suitable for 230 V, 50 Hz, singlephaseACSupply,earthingetc.complete as required.1200 mm sweep |
| 880 | Supply of AC230/250 volts, 50 HZ exhaust fansincludingproviding nuts,bolts,mountingframe and other accessories etc.Complete300 mm sweep 900 rpm |
| 881 | Supply,installation, testing and commissioning ofMainDistribution Boardsuitableforupto 125ampFPMCCBincomerandsingle/three phaseoutgoingMCB\"s,IP43protection,double metal door, factory fabricated, wall mounting type insurface/recess,powdercoated,415V/200 amp copper Bus Bar, earth and neutral bar, removableglandplates,cableglandsincluding connection with outgoing feeders completeinall respect. DB\"s shall be original factory fabricated of approvedmake.Theratesshallbeexcludingall incoming and outgoing circuit breakers.8 Way TPN |
| 882 | ProvidingandfixingoffollowingratingFourpole MCCB\"sattheincomerofMain/subdistribution boardswith connectionsetc.completeasrequired.100 Amp FP MCCB(16 KA) |
| 883 | Supplying, fixing, connecting, testing and commissioning of followingrating, ISI marked (IS 8828) 240 / 415 volts, 10 KA, Miniature Circuit Breaker(MCB) ofsingle/double/three/ four polesintheexistingMCBDBorinexistingMS enclosure complete in all respects25 Amp. TP MCB |
| 884 | 40 Amp.TP MCB |
| 885 | Supply, installation, testing and commissioning of electrical pane, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection. Thepanelsheetstructureshallundergo seventank pre-treatmentprocess beforepainting. The sheet steel shall be all of 2.2mm thick CRCA sheet.All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers.The panel height shall not exceed 2200mmandthemaximumoperatingheightforany switchgear shall not be more than 1700mm.The panel shallbeprovidedwithminimum75mmbasechannel frame fabricated from ISMC sections.All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable. Continuousearthbusshallrunalroundthe panel with earthingstudsprovidedatminimum2places. The control wiring shall be carried out with minimum1.5/2.5 sqmm copper wires and adequatenumberofNO/NC,potentialfreecontacts incorporated for remote operation of the starters. Propersizedcableterminationglandplatesshallbe provided oncable alleys and knockouts for same shall beprovidedduringfabricationstage itself. The panel shallbeprovidedwithathermostaticallycontrolled heatingarrangement(200W)totakecareofhigh humidity conditions.A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel.Panel shall be so designed at to have minimum 20% spare feeders/space.Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement. All cable terminations shall be from top. The complete panel shall be fuse less type,for control circuits 2A/6A MCB\"s to be used. Allbusbarsshallbeofaluminium,electrolyticgrade only. Maximumdesigndensityshallnotexceed1 Amps/Sqmm. Allbusbarsshallbeinsulatedwith colouredheatshrinkablePVCsleeved. Allbusbar supports shall be non hygroscopic DMC/SMC supports. Thepanelshallbemanufacturedinconformanceto requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. The minimum clearances between bus bars shall be as follows : Phase to phase - minimum 20mm Phase to neutral-minimum 15mm Main L.T. Panel -G.F. Incoming : One (1) No 300Amp. 4 pole 1 NO. Metering : One(1)No.(0-500V)96x96Sqmmvoltmeterwith control fuse & selector switch. One(1)No.(0-300A)96x96SqmmCToperated Ammeter with selector switch, CTs etc. One (1) Set of Phase Indication Lamp. Bus Bar : One (1) No. 300 Amp. TPN aluminimum bus bar of suitable length. Outgoing : Phase indication lamps on nos outgoing to be provided. 100 Amps TPN-1No. OR outgoing as per site requirment |
| 886 | ProvidingandLayingunplastisizedrigidPVCpipe conformingtoIS:13592typeAincludingjointing, cutting andmakinggoodthewalls&floorsasper requirement.150mm |
| 887 | PLUMBING WORKSProvidingandfixingwhitevitreouschina extended wall mounting water closet of size 780x370x690mmofapprovedshape includingproviding&fixingwhitevitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4litre/8litres),includingseatcover,and cisternfittings,nuts,boltsandgasketetccomplete. |
| 888 | Providing & fixing white vitreous china wash basin with C.I. brackets painted white,15mmC.P.brasspillartaps,C.P.brass chainwithrubberplug,32mmC.P.brass waste of standerd pattern including cutting & making good the walls wherever required.a)White Vitreous China Wash basin size 630x450mmwithapairof15mmC.P.brass pillar taps |
| 889 | ProvidingandfixingP.V.C.wastepipefor sinkorwashbasinincludingP.V.C.wastefittings complete. Semi rigid pipe32 mm dia |
| 890 | Providingandfixing600x450mmbevelled edgemirrorofsuperiorglass(ofapproved quality) complete with 6mm thick hard board groundfixedtowoodencleatswithC.P.brass screws and washers complete. |
| 891 | Providingandfixingwhitevitreouschina flat back half stall urinal of size 580*380*350mm with white PVC automatic flushingcistern,withfittings,standardsizeC.P. brass flush pipe, spreaders with unions andclamps(allinD.P.brass)withwaste fitting as per IS : 2556, C.I. trap with outlet gratingandothercouplingsinC.P.brass including painting of fittings and cutting and makinggoodthewallsandfloorswhereverrequired:RangeofTwohalfstallurinalswith5litre PV.C. automatic flushing cistern. |
| 892 | Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitionsbycuttingachaseofappropriate widthwithchasecutterandembeddingthe stone in the chase withepoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size)asperdirectionofEngineer-in-chargeand finished smooth.Granite Stone of approved shade |
| 893 | CP Brass fittingsProviding and fixing unplasticised PVC connection pipe with brass unions45 cm length15 mm nominal bore |
| 894 | Providingandfixing C.P.brass bibcock of approved quality conforming to IS:8931a) 15 mm nominal bore |
| 895 | ProvidingandfixingC.P.brasslongbody bibcockofapprovedquality conformingto IS standards andweighing not less than 690gms.a) 15 mm nominal bore |
| 896 | ProvidingandfixingC.P.brassanglevalve for basin mixer and gyser points of approved quality conforming to IS:8931a) 15 mm nominal bore |
| 897 | Providing and fixing unplasticised-PVC pipe clipsofapproveddesigntounplasticised- PVC pipes by means of 50x50x50 mm hard woodplugs,screwedwithMSscrewsof required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarsesand)andmakinggoodthewall etc.complete.110mm |
| 898 | 90mm |
| 899 | Providingandlayingcementconcrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size)aroundP.V.CSoilandwastepipeincludingbed concrete as per standard design(embedded in the flooring / ground)110 mm dia |
| 900 | 90 mm dia |
| 901 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conformingtoIS:13592TypeAincluding jointingwithsealringconformingtoIS: 5382leaving10mmgapforthermalexpansion.110 mm |
| 902 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVCrainwaterpipesconformingto IS:13592 TypeAincludingjointingwith seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.Bend 87.5 degree110 mm Bend |
| 903 | Shoe (Plain)110 mm Shoe |
| 904 | Providingandfixingtotheinletmouthof rain water pipe cast iron grating 15 cm diameterandweighingnotlessthan440grams. |
| 905 | Providing and fixing unplasticised-PVC pipe clipsofapproveddesigntounplasticised- PVC rain water pipes by means of 50x50x50 mmhard wood plugs,screwed withMS screwsofrequiredlengthincludingcutting brickworkandfixingincementmortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 906 | Providingandfixing15cm wide45cm over all semi circular plain G.S. sheet gutter with ironbrackets40x3mmsize,bolts,nutsand washers etc. including making necessary connections with rain water pipes complete.0.80mm thick with zinc coating not less than275 gm/m2 |
| 907 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4(1cement:2coarsesand:4graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,roundingtheedgesand making and finishing the outlet complete. |
| 908 | ProvidingandfixingChlorinatedPolyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply includingallCPVCplain&brassthreaded fittingsi/cfixingthepipewithclampsat 1.00mspacing. Thisincludesjointingof pipes & fittings with one step CPVC solvent cementandthecostofcuttingchasesand making good thesame includingtestiang of joints complete as per directionof Engineerin Charge.Concealed work including cutting chases andmaking good the walls etc.20mm dia nominal outer dia pipes |
| 909 | 25mm dia nominal outer dia pipes |
| 910 | 32mm dia nominal outer dia pipes |
| 911 | Providingandfixinggunmetalgatevalvewith wheel of approved quality.25mm dia nominal bore |
| 912 | 32mm dia nominal bore |
| 913 | 40mm dia nominal bore |
| 914 | Providing and placing on terrace (at all floor levels)polyethylenewaterstoragetankISI: 12701markedindicatingtheBISLicense No.withcoverandsuitablelocking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent havingvalid ISI license]. Capcity in Per Liters |
| 915 | Providing and placing on terrace (at all floor levels)polyethylenewaterstoragetankISI: 12701markedindicatingtheBISLicense No.withcoverandsuitablelocking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent havingvalid ISI license]. Capcity in Per Liters Pipes,cablesetc.exceeding80mmdiabutnot exceeding 300mm. |
| 916 | Providing,layingandjointingglazed stonewarepipes grade\"A\" withstiff mixture of cement mortar in the proportion of 1:1 (1 cement:1finesand)includingtestingof joints etc. complete. 100mm diameter |
| 917 | Providing and laying cement concrete 1:5:10 (1cement:5coarsesand:10gradedstone aggregate 40mm nominal size) all roundS.W.pipesincludingbedconcreteasper 100mm dia SW pipe |
| 918 | ProvidingandlayingNon pressure NP2 class(lightduty)RCCpipewithcollars jointed withstiffmixtureofcement mortar intheproportionof1:2(1cement:2fine sand ) includingtestingof joints etc. 150 mm.dia. RCCPipes |
| 919 | Providing and laying cement concrete 1:5:10 (1cement:5coarsesand:10gradedstone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design150 mm.dia. RCCPipes |
| 920 | Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating,brickmasonrychamberwithwater tight C.I. cover with frame of 300 x300 mm size(inside)theweightofcovertobenot lessthan4.50kgandframetobenotless than 2.70 kg as per standard design150 x 100 mm size P type With Sewer bricks conforming to IS : 4885 |
| 921 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand)RCCtopslabwith1:2:4mix(1cement:2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1cement:4coarsesand:8gradedstone aggregate40mmnominalsize)inside plastering12mmthickwithcementmortar 1:3(1cement:3coarsesand)finishedwith floatingcoatfoneatcementandmaking channels in cement concrete 1:2:4 (1 cement:2coarsesand:4gradedstoneaggregate 20mmnminalsize)finishedwithafloating coat of neat cement complete as per standard design.Inside size 90x80cms and 45cms deep includingCIcoverwithframe(lightduty) 455x610mminternaldiamensionstotal weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight offrame 15kg). With FPS bricks of class designation 75(i) For Sewer Line Extra for depth for manholes: |
| 922 | Size 90X80 cm with FPS bricks (class I ). |
| 923 | Providing M.S. foot rests including fixing in manholes with20x20x10 cmcement concreteblocks1:3:6(1 cement:3coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar |
| 924 | Providing and fixing on wall face unplasticised Rigid PVC soil and waste water pipes conforming to IS : 13592 Type B including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes.a) 110mm dia P.V.C. pipe |
| 925 | b) 90mm dia P.V.C. pipe |
| 926 | Providing & fixing UPVC Floor trap of self cleansingdesign withCPJali completein allrespects.(Make:Supreme/Finolex/Prince)P-Trap type Floor Trap 110 x 110mm |
| 927 | Providing and fixingterminal guard. a) 110mm |
| 928 | b) 90mm |
| 929 | Providing and fixing on wall face unplasticised-PVCmoulded fittings/accessories for unplasticised Rigid PVCpipes includingjointingwithseal ring leaving 10 mm gap for thermal expansion.110mm bend |
| 930 | 90 mm bend |
| 931 | Coupler 110mm |
| 932 | 90mm |
| 933 | Single tee with door 90x90x90 mm |
| 934 | 110x110x110 mm |
| 935 | Providing & fixing Towel Rail 300mm Long For Wash Basin Area |
| 936 | Providing & fixing Soap Dispenser with MetallicbottleJAQUARACN-CHR-1137N |
| 937 | Providing&fixingBottleTrap(With InternalPartition)32mmSizeWith250mm &190mmLongWallConnectionPipes& Wall Flange JAQUAR ALD-CHR-769 |
| 938 | ProvidingandfixingHandShower(Health Faucet) with 8mm Dia, 1 Meter Long FlexibleTube&WallHook(forE.W.C.) JAQUAR ALD-CHR-573 |
| 939 | ProvidingandfixingC.P.brassTwo-way anglevalveforEWCpoints&forfixing AblutionHealthFauctofapprovedquality conforming to15 mm nominal bore |
| 940 | Providing and fixing clean out plug 110 mm dia. |
| 941 | TUBE WELL AND INSTALLATION OF SUBMERSIBLE PUMP (90 M. DEPTH)Boring/drillingborewellofrequireddiaforcasing/ strainer pipe,bysuitablemethodprescribedinIS:2800(partI), includingcollectingsamplesfrom differentstrata,preparing and submitting strata chart/ bore log, including hire & runningchargesofallequipments,tools,plants& machineries required for the job, all complete as per direction ofEngineer-in-charge,upto90metredepthbelowgroundlevel.300 mm dia |
| 942 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessoriesetc.all complete,for all depths, asper directionof Engineer -in-charge.100 mm nominal size dia |
| 943 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS)pipeswithribs,conformingtoIS:12818,including hire & labour charges, fittings & accessories etc. allcomplete,foralldepths,asperdirectionofEngineer-in-100 mm nominal size dia |
| 944 | Gravelpackingintubewellconstructioninaccordancewith IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, allcomplete as per direction of Engineer-in-charge. |
| 945 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable wateryield without sand content (beyond permissible limit)withrequiredcapacityaircompressor,runningthe compressorforrequiredtimetillwellisfullydeveloped, measuringyieldofwellby“V”notchmethodoranyother approved method, measuring static level & draw down etc. by stepdraw down method, collectingwater samples& getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and directionof Engineer-in-charge. |
| 946 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of :100 mm dia |
| 947 | Providing and fixing M.S. clamp of required dia to the top of casing/housingpipeoftubewellasperIS:2800(partI), includingnecessarybolts&nutsofrequiredsizecomplete.100 mm clamp. |
| 948 | Providing and fixing Bail plug/ Bottom plug ofrequired dia tothebottomofpipeassemblyoftubewellasperIS:2800(part I). 100 mm dia. |
| 949 | SupplyofsubmersiblepumpofmakeKSB2.0 HPwithcontrol panel, support wire etc. complete. |
| 950 | Providing2corePVCinsulatedsubmersibblecablefrompump panel to submersible pump |
| 951 | ProvidingandfixingG.I.pipescompletewithG.I.fittingsincluding trenching and refilling etc. 32 mm dia nominal bore |
| 952 | Providing and fixing gun metal gate valve with C.I. wheel ofapprovedquality (screwed end) |
| 953 | Supply of 100mm dia Johnson screen. |
| 954 | Servant RoomEarth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-incharge.All kinds of soil |
| 955 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 956 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M25 grade with minimum cementcontent of 330 kg /cum |
| 957 | All works above plinth level upto floor V level, As in item 3 but for the lighter beams i.e.having spans upto 6 m. (Using 1:1.5:3 Mix concrete) |
| 958 | All works above plinth level upto floor V level, As in item 3 above but forslabs (Using 1:1.5:3 Mix concrete) |
| 959 | All works upto plinth level, As in item 3 but for the Footing (Using 1:1.5:3 Mix concrete) |
| 960 | All works above plinth level upto floor V level, As in item 3 but for the Column(Using 1:1.5:3 Mix concrete) |
| 961 | Reinforcement for RCC work including straightening, cutting,bending, placing in position complete. -Thermo-Mechanically Treated |
| 962 | Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete |
| 963 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc |
| 964 | Diluting and injecting chemical emulsion for POST- CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 965 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 966 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse |
| 967 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse |
| 968 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hingeswith necessary screws |
| 969 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Sal wood |
| 970 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 971 | Providing and fixing bright finished brass nos butt nos with necessary screws etc. complete125x85x5.5mm(heavy type) |
| 972 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :250x10 mm |
| 973 | Providing and fixing bright finished brass door latch with necessary screws etc. complete.300x16x5 mm |
| 974 | Providing and fixing bright finished brass handles with screws etc. complete.125 mm |
| 975 | Providing and fixing bright finished brass hangging type floor door stoper with necessary screws etc. compelte. |
| 976 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) |
| 977 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) |
| 978 | 12 mm cement plaster 1:3( 1 cement: 3 coarse sand) finished with a floating coat of near cement |
| 979 | Add for plaster drip course/ groove in plastered surface or moulding toR.C.C. projections. |
| 980 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 981 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shadeArea of slab over 0.50 sqm |
| 982 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/ 10 sqm) over and including priming |
| 983 | Finishing with Deluxe Multi surface paint system for interiors and exteriorsusing Primer as per manufacturers specifications :Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.80 ltr/10 sqm of approved brand and manufacture |
| 984 | Wall painting with acrylic emulsion paint, having VOC (Volatile OrganicCompound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to |
| 985 | French spirit polishing : Two or more coats on new works including a coat ofwood filler |
| 986 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured |
| 987 | Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete. |
| 988 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass |
| 989 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and |
| 990 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access |
| 991 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 992 | Servant Room ELECTRICALINSTALLATIONSWIRING POINTS AND SUBMAINSPoint wiring in PVC ConduitWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed mediumclass PVC conduit, with modularswitch,modularplate,suitableGIboxandearthingthe point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 993 | Power plug wiring in PVC conduit (2 x 4 sqmm.) :-Wiring for light/ power plug with 2X4 sq. mm FRLS PVCinsulatedcopperconductorsinglecorecableinsurface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulatedcopperconductorsinglecorecableforloopearthingas required. |
| 994 | Circuit / Sub main wiring in PVC conduit :-Wiringforcircuit/submainwiringalongwithearthwirewiththe followingsizesofFRLSPVCinsulatedcopperconductor,single corecableinsurface/recessedmediumclassPVCconduitas2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. Earth wire |
| 995 | 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire |
| 996 | 4 x 6 sq.mm. + 2 x 6 sq.mm. Earth wire |
| 997 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 998 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 999 | SupplyingandfixingoffollowingsizesofmediumclassPVC conduitalongwithaccessoriesinsurface/recessincludingcutting the wall and making good the same in case of recessed conduit as20 mm. |
| 1000 | 25 mm. |
| 1001 | 32 mm. |
| 1002 | S/F light plug point modular type accessories :-Supplying andfixing suitable size GI boxwith modularplate and coverinfrontonsurfaceorinrecess,includingprovidingand fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required |
| 1003 | S/F power plug point modular type accessories :-Supplying andfixing suitable size GI boxwith modularplate and coverinfrontonsurfaceorinrecess,includingprovidingand fixing6pin5/6&15/16Amodularsocketoutletand15/16A modular switch, connections etc. as required. |
| 1004 | S/F modular type electronic fan regulator :-Supplyingandfixingtwomodulesteppedtypeelectronicfan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 1005 | S/F modular type blanking plate :-Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 1006 | S/F MODULAR BOXES, BASE & COVER PLATE :-Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular switches inrecessetc as required1 or 2 Module (75 mm x 75 mm) |
| 1007 | DISTRIBUTIONBOARDS,MCB\"s, MCCB\"sANDSFU\"sSupplying and fixing following way, horizontal type three pole and neutral,sheetsteel,MCBdistributionboard,415V,onsurface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,dinbar,interconnections,powderpaintedincludingearthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door, horizontal type |
| 1008 | 6 way (4 + 18), Double door, horizontal type |
| 1009 | Supplying andfixing 5A to32A rating, 240/415V, 10kA, \"C\" curve,miniaturecircuit breakersuitableforinductive loadof followingpolesintheexistingMCBDBcompletewith connections, testing and commissioning etc. as required single pole |
| 1010 | Supplying and fixing following rating, four pole, 415 V, isolator in theexistingMCBDBcompletewithconnections,testingand commissioning etc. as required40 amps. |
| 1011 | 63 amps. |
| 1012 | Supplying&fixingsinglepole,blankingplateintheexisting MCBDBcomplete etc. as required. |
| 1013 | Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug topalongwith20A\"C\"curve,TPMCB,insheetsteelenclosure,on surface or in recess, with chained metal cover for the socket out let andcomplete with connections, testing and commissioning etc. as required. |
| 1014 | G.I.EARTHINGEarthingwithG.I.earthplate600mm X600mm X6mm thick including accessories, and providing masonry enclosure with cover platehavinglockingarrangementandwateringpipeof2.7metre long etc. with charcoal/ coke and salt as required. |
| 1015 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below groundasstripearthelectrode,includingconnection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be donebyoverlappingandwith2setsofG.I.nutbolt&spring washer spaced at 50mm) |
| 1016 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 1017 | ERECTIONOFLIGHTINGFIXTURESANDFANSInstallation,testingandcommissioningofceilingfan,including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mmFRLSPVCinsulated,copperconductor,singlecorecable, includingprovidingandfixingphenoliclaminatedsheetcoveron the fan box etc. as required. |
| 1018 | Supply and fixing of LED Tube Light with batten suitable for up to1X22wattLEDtubelightfittingincludingtubeonSurface complete in all respect. CAT- AAA |
| 1019 | Supply and fixing of 12 Watt to 15 Watt indoor Recess mounting LEDSquare Fittingfor ArmstrongCeiling havingPowder coated diecastaluminiumhousingwithextendedheatsink,diffuserof Polycarbonate meterial and driver set complete in all respect. CAT-AAA |
| 1020 | Supplyandfixingofrecess/Surface/Pendentmountinground6 Watt8WattLEDDownLighterhavingPowdercoateddiecast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA |
| 1021 | Supplyandfixingofrecessmountinground15to18WattLED DownLighterhavingPowdercoateddiecastaluminiumhousing withheatsink,diffuser/Reflectoranddriversetcompleteinall respect. CAT- AAA |
| 1022 | PART (B) -- NON SCHEDULED ITEMS (AS PER MARKET RATES)Supply,Installation,Testingand Commissioningof 1200mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)Motor,classofinsulation:B,3Nosblades,30cm long down rod, 2 Nos canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum6.85, Air deliveryminimum215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speedcontrolandallremainingaccessoriesincludingsafetypin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.1200 mm sweep |
| 1023 | Providing and fixing of following rating Four poleMCCB\"s at the incomerofMain/subdistributionboardswith connectionsetc. complete as required.100 Amp FP MCCB(16 KA) |
| 1024 | Supplying, fixing, connecting, testing and commissioning of following rating,ISImarked(IS8828)240/415volts,10KA, MiniatureCircuitBreaker(MCB) ofsingle/double/three / fourpolesintheexistingMCBDBorinexistingMSenclosure complete in all respects.25 Amp. TP MCB |
| 1025 | Boundry Wall (CE, CTP & CAO Residence)Contsruction of Boundry wall as per drawing with all complete. As per direction of Engineer In Charge |
| 1026 | EXTERNAL ELECTRIFICATION & LANDSCAPE LIGHTINGSupply & Fixingof’ 5mtr long Antique designed pole with castaluminium/ironbasewithgalvanized steelpipeand decorativetoppaintedwithprimerthenpaintedwithdull finished polyurethane paint fitted with MCB and connector withdecorativebracketsinglearmformountingof1nos drop down lantern with body made out ofspun aluminium and fitted with poly carbonate diffuser in 110W with built in surge protector and lumn output>110lmn/watt. Design as perArchitectincharge. (Make-Twinklelite/wipro/K Lite/ Luster) |
| 1027 | Supplying Testing & Installation of Led Flood Light Luminaire50W PhilipsMakeModel-BVP140Led50 CW PSU WH/ Wipro/ Luster etc all complete of directionof engineer in charge. |
| 1028 | Supplying Testing & Installation ofLed Flood Light Luminaire 100WV Philips Make Model- BVP 142 Led 100 CW PSU WH / Wipro/ Lusteretc all complete of direction of engineer in charge. |
| 1029 | Supply and fixing of decorative16 Watt LEDbollard luminaire with driver set confirming to IP 65 protection complete in all respect. |
| 1030 | Earthingwithcopperearthplate 600mm X600mm X 3 mmthickincludingaccessories,andprovidingmasonry enclosure with cover plate having locking arrangement and wateringpipeof2.7metrelongetc.withcharcoal/cokeand salt as required |
| 1031 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 1032 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metrebelowgroundasstripearthelectrode,including connection/terminatingwithnut,bolt,spring,washeretc. as required. (Jointing shall be done by overlapping and with 2 sets of brassn nut bolt & spring washer spaced at 50mm) |
| 1033 | Supply and layingofaluminium conductorPVCinsulated armouredservedsheathedcables1100Voltsgradeata depth of 750 mm below ground level over a cushion of 75mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S.clampsetc.ofsuitablesizeorasdirectedby the Engineer-Incharge ,complete in all respect. The armouring ofthecableshallbeproperlyconnectedwiththeearth conductor by clamps etc.6.00 Sqmm 4 Core |
| 1034 | 25.00 Sqmm 3.5 Core |
| 1035 | 70.00 Sqmm 3.5 Core |
| 1036 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect.40 A TPN |
| 1037 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench,complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 1038 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 1039 | LANDSCAPE & HORTICULTUREProvidingandstackingofBottlepalmofht.270-300 cm bottom girth 40-50cm well developed in big HDPE bags as per diection of the officer-in-charge. |
| 1040 | ProvidingandstackingofFicusbenjamina(green)of height150-165cm.,bushywithhealthybranchesand lush green foliage in big size HDPE bags as perdirection of the officer-in-charge. |
| 1041 | Providing and stacking of Ficus bengalensis krishna of height 75-90 cm., multibranched in earthen pots of size 30 cm as per direction of the officer-in-charge |
| 1042 | ProvidingandstackingofTectonagrandis(Teak)of height 150-165 cm. in big polybags of size 25 cm as perdirection of the officer-in-charge. |
| 1043 | ProvidingandstackingofWashingtoniafilifeapalm stem ht. 90-105cm with6-7healthy leaveslushgreen leaveswelldevelopedinbigsizeHDPEBagsasperdirection of the officer-in-charge. |
| 1044 | Providing and Displaying Sunflower hybrid well developed 15 to 20 cm ht. with fresh & healthy foliage at blooming stage in 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge. |
| 1045 | Providing and Displaying Creeper Rose variety 3 to 4 healthy branch 60 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer-in-charge. |
| 1046 | Providing and Displaying Standard Rose (H.T. variety) 3 to 4 healthy branch 90 cm and above ht. well developed with one and above flowers in 25 Earthen Pot, as per direction of the officer-in-charge. |
| 1047 | Providing and Displaying Bamboo Buddha vally variety with umbrella shape having 120 to 135 ht. with fresh & healthyfoliagewelldevelopedin40cmCementpot multy branch,bushy asperdirectionoftheofficer-in- charge. |
| 1048 | Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per directionof the officer-in-charge. |
| 1049 | Providing and stacking of Plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. |
| 1050 | Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushty shape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & asper direction of the officer-in-charge.. |
| 1051 | Trenchinginordinarysoiluptorequireddepth including removal and stacking of serviceable materialsandthendisposingofasdirectedand spreadingearth&neatly levelling,breakingclods etc.andmakingthetrenchedareawithdesigned mounds,pathsandsittingspacesetc.toproper levelsbyfillingwithearthorearthmixedwith manureandproperlywateringcompleteworkin required topography as per drawing &specifications. |
| 1052 | Supplying and stacking of good earth at site including royalty but including carriage1km (earth measusredinstackswillbereducedby20%for |
| 1053 | Supplying andstacking atsitedumpmanure from approved source,includingcarriageupto1km (manure measured in stacks will be reduced by8%for payment) |
| 1054 | Mixing earth and manure in specified proportion oras directed. |
| 1055 | Rough dressing the trenched ground includingbreaking the clods. |
| 1056 | Fine dressing the ground |
| 1057 | Spreadingof mixedgoodearthandmanurein specified proportions as aboveand inrequiredthickness. |
| 1058 | Uprooting weeds from the trenched area after 10 to15 days after flooding with water including disposal of uprooted vegetation. |
| 1059 | Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness on existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface withlightrollermakethesurfacesmoothenand light watering the same, as per direction of officerin charge |
| 1060 | Preparation of mounds of various size and shape by availableexcavated/suppliedearthinlayersnot exceeding 20 cm in depth, breaking clods, watering of nos layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge. |
| 1061 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering |
| 1062 | TREMIX PARKINGExcavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 1063 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 1064 | Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete. |
| 1065 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 1066 | Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete. |
| 1067 | Mildsteel or ironinplainworksuchas reinforcedconcrete orreinforced ,brick work (when not includedin anover all rates )wrought to required shapeas necessary including bendingforproper completion of theworkand includingsupplyof steelitswastage bendhooksand authorised overlapping shallbe measured upto floor two level. |
| 1068 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 1069 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of jointsexcept at sharp curve shall not to more than 5mm), including making drainage opening whereverrequired complete etc. as per direction of Engineer- in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 1070 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 1071 | DrainEarth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil |
| 1072 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominalsize) |
| 1073 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cementcontent, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Concrete of M25 grade with minimum cement content of 330 kg /cum All works above plinth level upto floor V level |
| 1074 | As in item 4 above but forslabs |
| 1075 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-MechanicallyTreated bars |
| 1076 | RAIN WATER HARVESTING PITSEarthworkinexcavationbymechanical means (Hydraulic excavator) / manual meansinfoundationtrenchesordrains (notexceeding1.5minwidthor10sqm onplan),includingdressingofsidesand ramming of bottoms, lift upto 1.5 m, includinggettingouttheexcavatedsoil anddisposalofsurplusexcavatedsoilas directed, within a lead of 50 m.All kinds of soil |
| 1077 | Brick work with common burnt clay F.P.S. (nonmodular)bricksofclassdesignation7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cementmortar1:6(1cement:6coarsesand) |
| 1078 | CEMENTPLASTERWITHAFLOATINGCOAT OF NEAT CEMENT12mmcementplasterfinished withafloating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand) |
| 1079 | Reinforcedcementconcreteworkin beams, suspended floors, roofs having slopeupto15°landings,balconies, shelves,chajjas,lintels,bands,plain window sills, staircases and spiral stair casesaboveplinthleveluptofloorfive level, excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3(1cement:1.5coarsesand (zone-III):3gradedstoneaggregate20 mm nominal size). RCC(1cement:1.5corasesand:3stoneaggregate) |
| 1080 | FORM WORKCenteringandshutteringincluding strutting, propping etc.and removal of form for all heights :Centeringandshutteringincluding strutting, propping etc.and removal of form for all heights : Suspended floors, roofs, landings,balconies and access platform |
| 1081 | STEEL REINFORCEMENTSteel reinforcement for R.C.C.work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. Hot rolled deformed bars |
| 1082 | Boring/drillingborewellofrequireddia forcasing/strainerpipe,bysuitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/borelog,includinghire&running charges of all equipments, tools,plants & machineriesrequiredforthejob,all completeasperdirectionofEngineer-in- charge,upto90metredepthbelow ground level.All types of soil300mm dia |
| 1083 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM)pipeofrequireddia,conformingto IS: 12818, including required hire and labourcharges,fittings&accessoriesetc. allcomplete,foralldepths,asper direction of Engineer -in-charge.150 mm nominal size dia |
| 1084 | Supplying, filling, spreading & leveling stonebouldersofsizerange5cmto20 cm,inrechargepit, inthe required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 1085 | Supplying, filling, spreading & leveling gravelsofsizerange5mmto10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 1086 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all completeasperdirectionofEngineer-incharge |
| 1087 | Gravel packing in tubewell construction in accordancewithIS:4097,including providinggravelfine/medium/coarse,in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 1088 | ProvidingandfixingM.S.clampof required dia to the top of casing/ housing pipeoftubewellasperIS:2800(partI), includingnecessarybolts&nutsof required size complete.150 mm clamp |
| 1089 | Providing and fixing Bail plug/ Bottom plug of required dia to thebottomofpipeassemblyoftubewellas per IS:2800 (part I).150mm dia |
| 1090 | Providing,fixinginpositionofISImarked UVstabilizedUPVCpipes forventing, Type-B as per IS : 13592 suitable for rubberringjointsforverticalpipesand solvent cement joints for horizontal pipes, includingallneccessaryspecialsand fittings (Make : Finalex/ Astral / Ashirwad) 75mmdia(WallThickness-3.2to3.8mm) |
| 1091 | Providingandfixinginpositionpre-castR.C.C. manhole cover andframe of required shape and approved quality Rectangularshape600x450mminternaldimensions |
| 1092 | Providingorangecoloursafetyfootrest of minimum 6 mm thick plastic encapsulatedasperIS:10910,on12mm dia. Steel bar conforming to IS:1786, having minimum cross section as 23mm x 25mmandoverallminimumlength263 mm and width as 165 mm with minimum112 mm space between protruded leg having 2 mm tread on top surface by ribbingorchequeringbesidesnecessary andadequatedanchoringprojectionson taillengthon138mmasperstandard drawingandsuitabletowithstandthe bendtestandchemicalresistancetestas per spaecifications and having manufacture\"spermanentidentification mark to be visible even after fixing, includingfixinginmanholeswith 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate20mmnominalsize)complete as per design. |
| 1093 | DG SET, SOLER PLANT,CCTV AND VRV/VRF SYSTEM ACSupplying, installation, testing and commissioning of silent type DG sets, AMF panel, bus ducting/ cables from DG sets to. essential panel, synchronizing panel where réquired, DG set enclosure room sound insulation/ventilation/smoke exhaust as required, earthing of DG set system, control cabling, fuel tank/piping, DG set exhaust piping/ exhaust chimney as per CPCB norms, civil works connected with DG sets including foundation as required. |
| 1094 | Supplying, installation, testing and commissioning of grid interactive roof Top solar photo voltaic power generation system including space frame |
| 1095 | EE, SE, OSD and JSBUILDING WORKEarth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil |
| 1096 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating nos deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m |
| 1097 | Diluting and injecting chemical emulsion for PRE- CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 1098 | Supplying and filling in plinth with sand under floors,including watering, ramming, consolidating and dressing complete. |
| 1099 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 1100 | Providing centering & shuttering including strutting, propping etc. & removal of form including all materials, labour and T & P etc. required for proper completion of work all completeFoundation, Footing, base of columns and plinth beam in any shape and size upto plinth level. |
| 1101 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 1102 | Lintels, beams, plinth beams, girders, bressumers andcantilevers |
| 1103 | Suspended floors, roofs, landings, balconies and accessplatform |
| 1104 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for thefollowing grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement contentof 330 kg /cumAll works up to Plinth level. |
| 1105 | All works AbovePlinth level & upto Floor V Level |
| 1106 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D ormore. |
| 1107 | Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement Mortar1:4 (1 cement :4 coarse sand) |
| 1108 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement :4 coarse sand) |
| 1109 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1cement :3 coarse sand) |
| 1110 | 15 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) |
| 1111 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) |
| 1112 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) |
| 1113 | Making grooves 10 to 12mmwidex8mm deep in plaster of the wallor in ceiling vertically or horizontally as required. |
| 1114 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).Second class teak wood |
| 1115 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 1116 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugsscrews etc |
| 1117 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). |
| 1118 | Providing & fixingsystem Profile Aniodised AluminiumWindow all complte as per direction of enginner in charge Fixed part |
| 1119 | Providing & fixingsystem Profile Aniodised Aluminium Window all complte as per direction of enginner in chargeCasement window with top pin |
| 1120 | Providing & fixingsystem Profile Aniodised Aluminium Window all complte as per direction of enginner in charge Slider 3T 3P Triple track (Tostom , Schuco) |
| 1121 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 1122 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacture\"s specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work |
| 1123 | French spirit polishing :Two or more coats on new worksincluding a coat of wood filler |
| 1124 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface evenand smooth complete. |
| 1125 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnablepriming coat with cement primer |
| 1126 | Finishing walls with textured exterior paint of required shade: New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 1127 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 1128 | Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. (Make Hilti/ Fisher/ Helifix)Frame anchor HRD-C 10x140 |
| 1129 | Providing and fixing aluminium sliding door bolts, ISImarked anodised anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm |
| 1130 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, withnecessary screws etc. complete : 200x10 mm |
| 1131 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, withnecessary screws etc. complete : 125 mm |
| 1132 | Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement..(40mm thickwith 20 mm nominal aggregate). |
| 1133 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. IN : toilet Block |
| 1134 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shadesexcept burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 1135 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete Double charged Vitrified Tile Polish finish Size 1200x600 mm |
| 1136 | Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red Area of slab over 0.50 sqm |
| 1137 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 1138 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 1139 | Providingandlayingintegralcementbasedwaterproofing treatmentincludingpreparationofsurfaceasrequiredfor treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using2.75kg/sqmofcementadmixedwithwaterproofing compound conforming to IS. 2645 and approved by Engineer- in-chargeovertheRCCslabincludingadjoiningwallsupto300 mm height including cleaning the surface before treatment.b)Layingbrickbatswithmortarusingbroken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar1:5(1cement:5coarsesand)admixedwithwater proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar ofmix1:5(1cement:5coarsesand)admixedwithwater proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoiningwallsupto300mmheightincludingroundingof junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed jointless cement mortar of mix 1:4 (1 cement:4 coarse sand) admixed with water proofing compoundconforming to IS : 2645 and approved by Engineer-in-charge |
| 1140 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm nos having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I.wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm longdry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum moisture resistant board |
| 1141 | Providing & Fixing of (Armstrong / USG Boral / Hunterdouglous) Soft Fibre Acoustical Suspended Ceiling System with Optra Beveled Tegular Edge Tiles With Armstrong Suprafine 15mm Exposed Grid.The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9 - 1.0, Colour Black, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in modulesize of 600x600x15mm, suitable for Green Building application, with Recycled content of 66% GW & 74% RW.The tile shall be laid on Armstrong Suprafine 32 with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 32mm& pull out strength of 100Kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system of Armstrong make. INSTALLATION: To comprise main runnerspaced at 1200mm securely fixed to the structural soffit using Armstrong suspension system (specifications below) at 1200mm maximum. The First/Last Armstrong suspension system at the end of nos main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm to form 1200 x 600 mm module.Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be Armstrong wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum.Installation to be carried out by Armstrong Trained Installation team &Installation should be carried out as per Armstrong recommended procedure. |
| 1142 | Providing and fixing Murga Jali-type false ceiling (wire mesh ceiling) with steel framework, suspended from the main ceiling, including finishing, suspension, framing, painting (if any), complete as per drawing and instructions of Engineer-in-Charge. |
| 1143 | Providing, supplying, and laying Stonex paving slabs / driveway stones over prepared base, with bedding, jointing, finishing, and all associated works, for vehicle traffic, complete as per drawings, manufacturer’s instructions, and Engineer‑in‑Charge directions |
| 1144 | High-Pressure Laminate (HPL) exterior façade includes supply and installation of weather-resistant HPL panels (typically 6-8mm thick) fixed on an aluminum or galvanized steel subframe. Panels are UV- stabilized, fire-rated, and come in various finishes. The scope covers mechanical fasteners, EPDM gaskets, sealants, and necessary support brackets, ensuring proper ventilation and thermal movement allowance. Rates generally range from ₹750 to ₹1,400 per sq. meter, including materials and labor, with a recommended 5-10% wastage. Final costs depend on panel brand, façade area, and site conditions. (Findermax or equiavlent ) |
| 1145 | Material: Aluminum Composite Panel (typically 4mm thickness) Finish: PVDF or Polyester coated, weather and UV resistantSub-frame: Aluminum or GI framing with brackets and fasteners Typical Rate: ₹900 to ₹1,600 per sqm (including supply, fabrication, and installation)Includes: ACP panels, substructure, fixings, sealants, and labor Note: Rates vary depending on brand, panel thickness, coating type, and site conditions |
| 1146 | Providing and fixing exterior-grade thin brick veneer tiles (approx. 2¼\" x 7⅝\", thickness ½\"–¾\"), of approved make, size, color, and texture, in [running bond / herringbone / stack bond] pattern, laid over prepared substrate with polymer-modified thin-set mortar or Type N/S cement mortar, including surface preparation, corner units, control joints, pointing, cleaning, and necessary scaffolding, all complete as per drawings, specifications, and instructions of the Engineer-in-Charge |
| 1147 | Providing and fixing mica laminate finish (decorative high-pressure laminate) of approved make, shade, and thickness (typically 1.0 mm) on furniture surfaces / wall paneling / partitions / doors, etc., using approved synthetic resin adhesive (Fevicol SH or equivalent) over prepared surface (e.g., BWP grade plywood, MDF, blockboard), including edge finishing, trimming, cleaning, and all tools, adhesives, materials, labour and incidentals, complete in all respects as per drawings and instructions of the Engineer-in-Charge (Sylvan , Green ply, Austin ) |
| 1148 | ELECTRICALINSTALLATIONSWIRING POINTS AND SUBMAINSPoint wiring in PVC ConduitWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copperconductorsinglecorecableinsurface/ recessedmediumclassPVCconduit,with modularswitch,modularplate,suitableGIbox and earthing the point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable etc.Group C |
| 1149 | Power plug wiring in PVC conduit (2 x 4sqmm.) :-Wiringforlight/powerplugwith2X4sq.mm FRLS PVCinsulatedcopperconductorsinglecorecablein surface/ recessed medium class PVC conduit alongwith1No.4sq.mmFRLSPVCinsulated copper conductor single core cable for loopearthing as required. |
| 1150 | Circuit / Sub main wiring in PVC conduit :-Wiringfor circuit/submain wiringalongwith earth wire with the following sizes of FRLS PVC insulatedcopperconductor,singlecorecablein surface/recessedmediumclass PVCconduit asrequired.2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. Earth wire |
| 1151 | 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire |
| 1152 | 4 x 6 sq.mm. + 2 x 6 sq.mm. Earth wire |
| 1153 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 1154 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 1155 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessedconduit as required20 mm. |
| 1156 | 25 mm. |
| 1157 | 32 mm. |
| 1158 | S/F light plug point modular type accessories :-SupplyingandfixingsuitablesizeGIboxwith modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modularsocketoutletand5/6Amodularswitch,connections etc. as required |
| 1159 | S/F power plug point modular type accessories :-SupplyingandfixingsuitablesizeGIboxwith modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 1160 | S/F modular type electronic fan regulator :-Supplyingandfixingtwomodulesteppedtype electronicfanregulatorontheexistingmodular plateswitchboxincludingconnectionsbutexcluding modular plate etc. as required. |
| 1161 | S/F modular type blanking plate :-Supplyingandfixingmodularblankingplateon the existing modular plate & switch box excludingmodular plate as required. |
| 1162 | TELEPHONE, TELEVISION AND DATA NETWORKTELEPHONE WIRING IN EXISTING CONDUIT :-Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmoredtelephonecableintheexisting surface/ recessed steel/ PVC conduit as required2 Pair |
| 1163 | S/F MODULAR BOXES, BASE & COVER PLATE :-Supplyingandfixing followingsize /modules, GI boxalongwithmodularbase&coverplatefor modular switches inrecessetc as required1 or 2 Module (75 mm x 75 mm) |
| 1164 | S/F MODULAR TYPE SWITCH / SOCKET :-Supplyingandfixingfollowingmodularswitch/ socket on the existing modular plate & switch box including connections but excluding modular plateetc as requiredTelephone Socket outlet |
| 1165 | DISTRIBUTIONBOARDS,MCB\"s, MCCB\"sANDSFU\"sSupplying and fixing following way, horizontal type threepoleandneutral,sheetsteel,MCB distribution board, 415V,onsurface/recess, complete with tinned copper bus bar, neutral bus bar,earthbar,dinbar,interconnections,powder paintedincludingearthingetc.asrequired.(Butwithout MCB/RCCB/Isolator)4 way (4 + 12), Double door, horizontal type |
| 1166 | 6 way (4 + 18), Double door, horizontal type |
| 1167 | Supplying andfixing 5A to32 A rating, 240/415 V,10kA,\"C\"curve,miniaturecircuitbreaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as requiredsingle pole |
| 1168 | Supplyingandfixingfollowingrating,fourpole, 415 V, isolator in the existing MCB DB complete with connections,testing andcommissioning etc.as required40 amps. |
| 1169 | 63 amps. |
| 1170 | Supplying& fixing singlepole, blankingplate in the existing MCBDBcomplete etc. as required. |
| 1171 | Supplying and fixing 20 A, 415 V, TPN Industrial type socketoutlet, with 4 pole and earth, metal enclosed plug topalongwith 20 A \"C\" curve, TPMCB, in sheet steel enclosure,onsurfaceorinrecess,withchained metalcoverforthesocketoutletandcomplete with connections,testing andcommissioning etc.as required. |
| 1172 | G.I.EARTHINGEarthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with coverplate having lockingarrangementandwateringpipeof2.7 metrelongetc.withcharcoal/cokeandsaltasrequired. |
| 1173 | Supplying and laying 25 mm X 5 mm G.I strip at0.50 metre below ground as strip earth electrode, includingconnection/terminatingwithG.I.nut, bolt,spring,washeretc.asrequired.(Jointing shallbedonebyoverlappingandwith2setsofG.I. nut bolt & spring washer spaced at 50mm) |
| 1174 | Providingandfixing25mmX 5mmG.I.strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 1175 | ERECTIONOFLIGHTINGFIXTURESANDFANSInstallation,testingandcommissioningofceiling fan,includingwiringthedownrodsofstandard length(upto30cm)with1.5sq.mmFRLS PVC insulated,copperconductor,singlecorecable, includingprovidingandfixingphenoliclaminated sheet cover on the fan box etc. as required. |
| 1176 | Installation of exhaust fan in the existing opening, includingmakinggoodthedamage,connection, testing, commissioning etc. as required. Upto 450mm sweep |
| 1177 | SupplyandfixingofLEDTubeLightwithbatten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect.CAT- AAA |
| 1178 | Supplyandfixingof12Wattto15Wattindoor RecessmountingLEDSquareFittingfor Armstrong Ceiling having Powder coated die cast aluminium housing with extended heat sink, diffuserofPolycarbonatemeterialanddriversetcomplete in all respect. CAT- AAA |
| 1179 | Supplyandfixingofrecess/Surface/Pendent mounting round 6 Watt 8 Watt LED Down Lighter havingPowdercoateddiecastaluminium housingwithheatsink,diffuser/Reflectorand driver set complete in all respect. CAT- AAA |
| 1180 | Supply and fixing of recess mounting round 15 to 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflectoranddriversetcompleteinallrespect. CAT- AAA |
| 1181 | Supply and fixing of sqaure Light 40-60Watt LED DownLight(600x600)mmhavingPowder coated die cast aluminium housing with heat sink, diffuser/Reflectoranddriversetcompleteinallrespect. |
| 1182 | Providing & Fixing of modular plate type white RJ 45CAT6Dataoutlet/informationoutletsETL verifiedtomeetorexceedTIA/EIAcategory6 requirements,universalwiringlabelpermittingto eitherT568AorT568B,ULlisted, forcomputer networking completeinallrespectwithcover plate, grid plate, screws, MS box, etc withconnections as required.1 Nos RJ 45 Data Outlet |
| 1183 | Supply,Installation,TestingandCommissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan withBrushLessDirectCurrent(BLDC)Motor, class of insulation: B, 3 Nosblades,30cmlongdownrod,2Noscanopies, shacklekit,safetyrope,copperwinding,Power Factor not less than 0.9, Service Value (CMM/W) minimum6.85,Airdeliveryminimum215CMM, 350 RPM (tolerance as per IS : 374-2019),THDlessthan10%,remoteorelectronic regulator unit for speed control and all remaining accessoriesincludingsafetypin,nutbolts, washers, temperaturerise=75degreeC(max.),insulationresistance more than 2 mega ohm, suitable for 230 V, 50 Hz, singlephaseACSupply,earthingetc.complete as required.1200 mm sweep |
| 1184 | Supply of AC230/250 volts, 50 HZ exhaust fansincludingproviding nuts,bolts,mountingframe and other accessories etc.Complete300 mm sweep 900 rpm |
| 1185 | Supply,installation, testing and commissioning ofMainDistribution Boardsuitableforupto 125ampFPMCCBincomerandsingle/three phaseoutgoingMCB\"s,IP43protection,double metal door, factory fabricated, wall mounting type insurface/recess,powdercoated,415V/200 amp copper Bus Bar, earth and neutral bar, removableglandplates,cableglandsincluding connection with outgoing feeders completeinall respect. DB\"s shall be original factory fabricated of approvedmake.Theratesshallbeexcludingall incoming and outgoing circuit breakers.8 Way TPN |
| 1186 | ProvidingandfixingoffollowingratingFourpole MCCB\"sattheincomerofMain/subdistribution boardswith connectionsetc.completeasrequired.100 Amp FP MCCB(16 KA) |
| 1187 | Supplying, fixing, connecting, testing and commissioning of followingrating, ISI marked (IS 8828) 240 / 415 volts, 10 KA, Miniature Circuit Breaker(MCB) ofsingle/double/three/ four polesintheexistingMCBDBorinexistingMS enclosure complete in all respects25 Amp. TP MCB |
| 1188 | 40 Amp.TP MCB |
| 1189 | Supply, installation, testing and commissioning of electrical pane, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection. Thepanelsheetstructureshallundergo seventank pre-treatmentprocess beforepainting. The sheet steel shall be all of 2.2mm thick CRCA sheet.All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers.The panel height shall not exceed 2200mmandthemaximumoperatingheightforany switchgear shall not be more than 1700mm.The panel shallbeprovidedwithminimum75mmbasechannel frame fabricated from ISMC sections.All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable. Continuousearthbusshallrunalroundthe panel with earthingstudsprovidedatminimum2places. The control wiring shall be carried out with minimum1.5/2.5 sqmm copper wires and adequatenumberofNO/NC,potentialfreecontacts incorporated for remote operation of the starters. Propersizedcableterminationglandplatesshallbe provided oncable alleys and knockouts for same shall beprovidedduringfabricationstage itself. The panel shallbeprovidedwithathermostaticallycontrolled heatingarrangement(200W)totakecareofhigh humidity conditions.A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel.Panel shall be so designed at to have minimum 20% spare feeders/space.Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement. All cable terminations shall be from top. The complete panel shall be fuse less type,for control circuits 2A/6A MCB\"s to be used. Allbusbarsshallbeofaluminium,electrolyticgrade only. Maximumdesigndensityshallnotexceed1 Amps/Sqmm. Allbusbarsshallbeinsulatedwith colouredheatshrinkablePVCsleeved. Allbusbar supports shall be non hygroscopic DMC/SMC supports. Thepanelshallbemanufacturedinconformanceto requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. The minimum clearances between bus bars shall be as follows : Phase to phase - minimum 20mm Phase to neutral-minimum 15mm Main L.T. Panel -G.F. Incoming : One (1) No 300Amp. 4 pole 1 NO. Metering : One(1)No.(0-500V)96x96Sqmmvoltmeterwith control fuse & selector switch. One(1)No.(0-300A)96x96SqmmCToperated Ammeter with selector switch, CTs etc. One (1) Set of Phase Indication Lamp. Bus Bar : One (1) No. 300 Amp. TPN aluminimum bus bar of suitable length. Outgoing : Phase indication lamps on nos outgoing to be provided. 100 Amps TPN-1No. OR outgoing as per site requirment |
| 1190 | ProvidingandLayingunplastisizedrigidPVCpipe conformingtoIS:13592typeAincludingjointing, cutting andmakinggoodthewalls&floorsasper requirement.150mm |
| 1191 | PLUMBING WORKSProvidingandfixingwhitevitreouschina extended wall mounting water closet of size 780x370x690mmofapprovedshape includingproviding&fixingwhitevitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4litre/8litres),includingseatcover,and cisternfittings,nuts,boltsandgasketetccomplete. |
| 1192 | Providing & fixing white vitreous china wash basin with C.I. brackets painted white,15mmC.P.brasspillartaps,C.P.brass chainwithrubberplug,32mmC.P.brass waste of standerd pattern including cutting & making good the walls wherever required.a)White Vitreous China Wash basin size 630x450mmwithapairof15mmC.P.brass pillar taps |
| 1193 | ProvidingandfixingP.V.C.wastepipefor sinkorwashbasinincludingP.V.C.wastefittings complete. Semi rigid pipe32 mm dia |
| 1194 | Providingandfixing600x450mmbevelled edgemirrorofsuperiorglass(ofapproved quality) complete with 6mm thick hard board groundfixedtowoodencleatswithC.P.brass screws and washers complete. |
| 1195 | Providingandfixingwhitevitreouschina flat back half stall urinal of size 580*380*350mm with white PVC automatic flushingcistern,withfittings,standardsizeC.P. brass flush pipe, spreaders with unions andclamps(allinD.P.brass)withwaste fitting as per IS : 2556, C.I. trap with outlet gratingandothercouplingsinC.P.brass including painting of fittings and cutting and makinggoodthewallsandfloorswhereverrequired:RangeofTwohalfstallurinalswith5litre PV.C. automatic flushing cistern. |
| 1196 | Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitionsbycuttingachaseofappropriate widthwithchasecutterandembeddingthe stone in the chase withepoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size)asperdirectionofEngineer-in-chargeand finished smooth.Granite Stone of approved shade |
| 1197 | CP Brass fittingsProviding and fixing unplasticised PVC connection pipe with brass unions45 cm length15 mm nominal bore |
| 1198 | Providingandfixing C.P.brass bibcock of approved quality conforming to IS:8931a) 15 mm nominal bore |
| 1199 | ProvidingandfixingC.P.brasslongbody bibcockofapprovedquality conformingto IS standards andweighing not less than 690gms.a) 15 mm nominal bore |
| 1200 | ProvidingandfixingC.P.brassanglevalve for basin mixer and gyser points of approved quality conforming to IS:8931a) 15 mm nominal bore |
| 1201 | Providing and fixing unplasticised-PVC pipe clipsofapproveddesigntounplasticised- PVC pipes by means of 50x50x50 mm hard woodplugs,screwedwithMSscrewsof required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarsesand)andmakinggoodthewall etc.complete.110mm |
| 1202 | 90mm |
| 1203 | Providingandlayingcementconcrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size)aroundP.V.CSoilandwastepipeincludingbed concrete as per standard design(embedded in the flooring / ground)110 mm dia |
| 1204 | 90 mm dia |
| 1205 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conformingtoIS:13592TypeAincluding jointingwithsealringconformingtoIS: 5382leaving10mmgapforthermalexpansion.110 mm |
| 1206 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVCrainwaterpipesconformingto IS:13592 TypeAincludingjointingwith seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.Bend 87.5 degree110 mm Bend |
| 1207 | Shoe (Plain)110 mm Shoe |
| 1208 | Providingandfixingtotheinletmouthof rain water pipe cast iron grating 15 cm diameterandweighingnotlessthan440grams. |
| 1209 | Providing and fixing unplasticised-PVC pipe clipsofapproveddesigntounplasticised- PVC rain water pipes by means of 50x50x50 mmhard wood plugs,screwed withMS screwsofrequiredlengthincludingcutting brickworkandfixingincementmortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 1210 | Providingandfixing15cm wide45cm over all semi circular plain G.S. sheet gutter with ironbrackets40x3mmsize,bolts,nutsand washers etc. including making necessary connections with rain water pipes complete.0.80mm thick with zinc coating not less than275 gm/m2 |
| 1211 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4(1cement:2coarsesand:4graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,roundingtheedgesand making and finishing the outlet complete. |
| 1212 | ProvidingandfixingChlorinatedPolyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply includingallCPVCplain&brassthreaded fittingsi/cfixingthepipewithclampsat 1.00mspacing. Thisincludesjointingof pipes & fittings with one step CPVC solvent cementandthecostofcuttingchasesand making good thesame includingtestiang of joints complete as per directionof Engineerin Charge.Concealed work including cutting chases andmaking good the walls etc.20mm dia nominal outer dia pipes |
| 1213 | 25mm dia nominal outer dia pipes |
| 1214 | 32mm dia nominal outer dia pipes |
| 1215 | Providingandfixinggunmetalgatevalvewith wheel of approved quality.25mm dia nominal bore |
| 1216 | 32mm dia nominal bore |
| 1217 | 40mm dia nominal bore |
| 1218 | Providing and placing on terrace (at all floor levels)polyethylenewaterstoragetankISI: 12701markedindicatingtheBISLicense No.withcoverandsuitablelocking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent havingvalid ISI license]. Capcity in Per Liters |
| 1219 | Providing and placing on terrace (at all floor levels)polyethylenewaterstoragetankISI: 12701markedindicatingtheBISLicense No.withcoverandsuitablelocking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent havingvalid ISI license]. Capcity in Per Liters Pipes,cablesetc.exceeding80mmdiabutnot exceeding 300mm. |
| 1220 | Providing,layingandjointingglazed stonewarepipes grade\"A\" withstiff mixture of cement mortar in the proportion of 1:1 (1 cement:1finesand)includingtestingof joints etc. complete. 100mm diameter |
| 1221 | Providing and laying cement concrete 1:5:10 (1cement:5coarsesand:10gradedstone aggregate 40mm nominal size) all roundS.W.pipesincludingbedconcreteasper 100mm dia SW pipe |
| 1222 | ProvidingandlayingNon pressure NP2 class(lightduty)RCCpipewithcollars jointed withstiffmixtureofcement mortar intheproportionof1:2(1cement:2fine sand ) includingtestingof joints etc. 150 mm.dia. RCCPipes |
| 1223 | Providing and laying cement concrete 1:5:10 (1cement:5coarsesand:10gradedstone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design150 mm.dia. RCCPipes |
| 1224 | Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating,brickmasonrychamberwithwater tight C.I. cover with frame of 300 x300 mm size(inside)theweightofcovertobenot lessthan4.50kgandframetobenotless than 2.70 kg as per standard design150 x 100 mm size P type With Sewer bricks conforming to IS : 4885 |
| 1225 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand)RCCtopslabwith1:2:4mix(1cement:2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1cement:4coarsesand:8gradedstone aggregate40mmnominalsize)inside plastering12mmthickwithcementmortar 1:3(1cement:3coarsesand)finishedwith floatingcoatfoneatcementandmaking channels in cement concrete 1:2:4 (1 cement:2coarsesand:4gradedstoneaggregate 20mmnminalsize)finishedwithafloating coat of neat cement complete as per standard design.Inside size 90x80cms and 45cms deep includingCIcoverwithframe(lightduty) 455x610mminternaldiamensionstotal weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight offrame 15kg). With FPS bricks of class designation 75(i) For Sewer Line Extra for depth for manholes: |
| 1226 | Size 90X80 cm with FPS bricks (class I ). |
| 1227 | Providing M.S. foot rests including fixing in manholes with20x20x10 cmcement concreteblocks1:3:6(1 cement:3coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar |
| 1228 | Providing and fixing on wall face unplasticised Rigid PVC soil and waste water pipes conforming to IS : 13592 Type B including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes.a) 110mm dia P.V.C. pipe |
| 1229 | b) 90mm dia P.V.C. pipe |
| 1230 | Providing & fixing UPVC Floor trap of self cleansingdesign withCPJali completein allrespects.(Make:Supreme/Finolex/Prince)P-Trap type Floor Trap 110 x 110mm |
| 1231 | Providing and fixingterminal guard. a) 110mm |
| 1232 | b) 90mm |
| 1233 | Providing and fixing on wall face unplasticised-PVCmoulded fittings/accessories for unplasticised Rigid PVCpipes includingjointingwithseal ring leaving 10 mm gap for thermal expansion.110mm bend |
| 1234 | 90 mm bend |
| 1235 | Coupler 110mm |
| 1236 | 90mm |
| 1237 | Single tee with door 90x90x90 mm |
| 1238 | 110x110x110 mm |
| 1239 | Providing & fixing Towel Rail 300mm Long For Wash Basin Area |
| 1240 | Providing & fixing Soap Dispenser with MetallicbottleJAQUARACN-CHR-1137N |
| 1241 | Providing&fixingBottleTrap(With InternalPartition)32mmSizeWith250mm &190mmLongWallConnectionPipes& Wall Flange JAQUAR ALD-CHR-769 |
| 1242 | ProvidingandfixingHandShower(Health Faucet) with 8mm Dia, 1 Meter Long FlexibleTube&WallHook(forE.W.C.) JAQUAR ALD-CHR-573 |
| 1243 | ProvidingandfixingC.P.brassTwo-way anglevalveforEWCpoints&forfixing AblutionHealthFauctofapprovedquality conforming to15 mm nominal bore |
| 1244 | Providing and fixing clean out plug 110 mm dia. |
| 1245 | TUBE WELL AND INSTALLATION OF SUBMERSIBLE PUMP (90 M. DEPTH)Boring/drillingborewellofrequireddiaforcasing/ strainer pipe,bysuitablemethodprescribedinIS:2800(partI), includingcollectingsamplesfrom differentstrata,preparing and submitting strata chart/ bore log, including hire & runningchargesofallequipments,tools,plants& machineries required for the job, all complete as per direction ofEngineer-in-charge,upto90metredepthbelowgroundlevel.300 mm dia |
| 1246 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessoriesetc.all complete,for all depths, asper directionof Engineer -in-charge.100 mm nominal size dia |
| 1247 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS)pipeswithribs,conformingtoIS:12818,including hire & labour charges, fittings & accessories etc. allcomplete,foralldepths,asperdirectionofEngineer-in-100 mm nominal size dia |
| 1248 | Gravelpackingintubewellconstructioninaccordancewith IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, allcomplete as per direction of Engineer-in-charge. |
| 1249 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable wateryield without sand content (beyond permissible limit)withrequiredcapacityaircompressor,runningthe compressorforrequiredtimetillwellisfullydeveloped, measuringyieldofwellby“V”notchmethodoranyother approved method, measuring static level & draw down etc. by stepdraw down method, collectingwater samples& getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and directionof Engineer-in-charge. |
| 1250 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of :100 mm dia |
| 1251 | Providing and fixing M.S. clamp of required dia to the top of casing/housingpipeoftubewellasperIS:2800(partI), includingnecessarybolts&nutsofrequiredsizecomplete.100 mm clamp. |
| 1252 | Providing and fixing Bail plug/ Bottom plug ofrequired dia tothebottomofpipeassemblyoftubewellasperIS:2800(part I). 100 mm dia. |
| 1253 | SupplyofsubmersiblepumpofmakeKSB2.0 HPwithcontrol panel, support wire etc. complete. |
| 1254 | Providing2corePVCinsulatedsubmersibblecablefrompump panel to submersible pump |
| 1255 | ProvidingandfixingG.I.pipescompletewithG.I.fittingsincluding trenching and refilling etc. 32 mm dia nominal bore |
| 1256 | Providing and fixing gun metal gate valve with C.I. wheel ofapprovedquality (screwed end) |
| 1257 | Supply of 100mm dia Johnson screen. |
| 1258 | Servant RoomEarth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-incharge.All kinds of soil |
| 1259 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 1260 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M25 grade with minimum cementcontent of 330 kg /cum |
| 1261 | All works above plinth level upto floor V level, As in item 3 but for the lighter beams i.e.having spans upto 6 m. (Using 1:1.5:3 Mix concrete) |
| 1262 | All works above plinth level upto floor V level, As in item 3 above but forslabs (Using 1:1.5:3 Mix concrete) |
| 1263 | All works upto plinth level, As in item 3 but for the Footing (Using 1:1.5:3 Mix concrete) |
| 1264 | All works above plinth level upto floor V level, As in item 3 but for the Column(Using 1:1.5:3 Mix concrete) |
| 1265 | Reinforcement for RCC work including straightening, cutting,bending, placing in position complete. -Thermo-Mechanically Treated |
| 1266 | Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete |
| 1267 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc |
| 1268 | Diluting and injecting chemical emulsion for POST- CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 1269 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 1270 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse |
| 1271 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse |
| 1272 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hingeswith necessary screws |
| 1273 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Sal wood |
| 1274 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 1275 | Providing and fixing bright finished brass nos butt nos with necessary screws etc. complete125x85x5.5mm(heavy type) |
| 1276 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :250x10 mm |
| 1277 | Providing and fixing bright finished brass door latch with necessary screws etc. complete.300x16x5 mm |
| 1278 | Providing and fixing bright finished brass handles with screws etc. complete.125 mm |
| 1279 | Providing and fixing bright finished brass hangging type floor door stoper with necessary screws etc. compelte. |
| 1280 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) |
| 1281 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) |
| 1282 | 12 mm cement plaster 1:3( 1 cement: 3 coarse sand) finished with a floating coat of near cement |
| 1283 | Add for plaster drip course/ groove in plastered surface or moulding toR.C.C. projections. |
| 1284 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 1285 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shadeArea of slab over 0.50 sqm |
| 1286 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/ 10 sqm) over and including priming |
| 1287 | Finishing with Deluxe Multi surface paint system for interiors and exteriorsusing Primer as per manufacturers specifications :Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.80 ltr/10 sqm of approved brand and manufacture |
| 1288 | Wall painting with acrylic emulsion paint, having VOC (Volatile OrganicCompound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to |
| 1289 | French spirit polishing : Two or more coats on new works including a coat ofwood filler |
| 1290 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured |
| 1291 | Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete. |
| 1292 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass |
| 1293 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and |
| 1294 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access |
| 1295 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 1296 | Servant Room ELECTRICALINSTALLATIONSWIRING POINTS AND SUBMAINSPoint wiring in PVC ConduitWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed mediumclass PVC conduit, with modularswitch,modularplate,suitableGIboxandearthingthe point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 1297 | Power plug wiring in PVC conduit (2 x 4 sqmm.) :-Wiring for light/ power plug with 2X4 sq. mm FRLS PVCinsulatedcopperconductorsinglecorecableinsurface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulatedcopperconductorsinglecorecableforloopearthingas required. |
| 1298 | Circuit / Sub main wiring in PVC conduit :-Wiringforcircuit/submainwiringalongwithearthwirewiththe followingsizesofFRLSPVCinsulatedcopperconductor,single corecableinsurface/recessedmediumclassPVCconduitas2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. Earth wire |
| 1299 | 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire |
| 1300 | 4 x 6 sq.mm. + 2 x 6 sq.mm. Earth wire |
| 1301 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 1302 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 1303 | SupplyingandfixingoffollowingsizesofmediumclassPVC conduitalongwithaccessoriesinsurface/recessincludingcutting the wall and making good the same in case of recessed conduit as20 mm. |
| 1304 | 25 mm. |
| 1305 | 32 mm. |
| 1306 | S/F light plug point modular type accessories :-Supplying andfixing suitable size GI boxwith modularplate and coverinfrontonsurfaceorinrecess,includingprovidingand fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required |
| 1307 | S/F power plug point modular type accessories :-Supplying andfixing suitable size GI boxwith modularplate and coverinfrontonsurfaceorinrecess,includingprovidingand fixing6pin5/6&15/16Amodularsocketoutletand15/16A modular switch, connections etc. as required. |
| 1308 | S/F modular type electronic fan regulator :-Supplyingandfixingtwomodulesteppedtypeelectronicfan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 1309 | S/F modular type blanking plate :-Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 1310 | S/F MODULAR BOXES, BASE & COVER PLATE :-Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular switches inrecessetc as required1 or 2 Module (75 mm x 75 mm) |
| 1311 | DISTRIBUTIONBOARDS,MCB\"s, MCCB\"sANDSFU\"sSupplying and fixing following way, horizontal type three pole and neutral,sheetsteel,MCBdistributionboard,415V,onsurface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,dinbar,interconnections,powderpaintedincludingearthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door, horizontal type |
| 1312 | 6 way (4 + 18), Double door, horizontal type |
| 1313 | Supplying andfixing 5A to32A rating, 240/415V, 10kA, \"C\" curve,miniaturecircuit breakersuitableforinductive loadof followingpolesintheexistingMCBDBcompletewith connections, testing and commissioning etc. as required single pole |
| 1314 | Supplying and fixing following rating, four pole, 415 V, isolator in theexistingMCBDBcompletewithconnections,testingand commissioning etc. as required40 amps. |
| 1315 | 63 amps. |
| 1316 | Supplying&fixingsinglepole,blankingplateintheexisting MCBDBcomplete etc. as required. |
| 1317 | Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug topalongwith20A\"C\"curve,TPMCB,insheetsteelenclosure,on surface or in recess, with chained metal cover for the socket out let andcomplete with connections, testing and commissioning etc. as required. |
| 1318 | G.I.EARTHINGEarthingwithG.I.earthplate600mm X600mm X6mm thick including accessories, and providing masonry enclosure with cover platehavinglockingarrangementandwateringpipeof2.7metre long etc. with charcoal/ coke and salt as required. |
| 1319 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below groundasstripearthelectrode,includingconnection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be donebyoverlappingandwith2setsofG.I.nutbolt&spring washer spaced at 50mm) |
| 1320 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 1321 | ERECTIONOFLIGHTINGFIXTURESANDFANSInstallation,testingandcommissioningofceilingfan,including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mmFRLSPVCinsulated,copperconductor,singlecorecable, includingprovidingandfixingphenoliclaminatedsheetcoveron the fan box etc. as required. |
| 1322 | Supply and fixing of LED Tube Light with batten suitable for up to1X22wattLEDtubelightfittingincludingtubeonSurface complete in all respect. CAT- AAA |
| 1323 | Supply and fixing of 12 Watt to 15 Watt indoor Recess mounting LEDSquare Fittingfor ArmstrongCeiling havingPowder coated diecastaluminiumhousingwithextendedheatsink,diffuserof Polycarbonate meterial and driver set complete in all respect. CAT-AAA |
| 1324 | Supplyandfixingofrecess/Surface/Pendentmountinground6 Watt8WattLEDDownLighterhavingPowdercoateddiecast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA |
| 1325 | Supplyandfixingofrecessmountinground15to18WattLED DownLighterhavingPowdercoateddiecastaluminiumhousing withheatsink,diffuser/Reflectoranddriversetcompleteinall respect. CAT- AAA |
| 1326 | PART (B) -- NON SCHEDULED ITEMS (AS PER MARKET RATES)Supply,Installation,Testingand Commissioningof 1200mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)Motor,classofinsulation:B,3Nosblades,30cm long down rod, 2 Nos canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum6.85, Air deliveryminimum215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speedcontrolandallremainingaccessoriesincludingsafetypin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.1200 mm sweep |
| 1327 | Providing and fixing of following rating Four poleMCCB\"s at the incomerofMain/subdistributionboardswith connectionsetc. complete as required.100 Amp FP MCCB(16 KA) |
| 1328 | Supplying, fixing, connecting, testing and commissioning of following rating,ISImarked(IS8828)240/415volts,10KA, MiniatureCircuitBreaker(MCB) ofsingle/double/three / fourpolesintheexistingMCBDBorinexistingMSenclosure complete in all respects.25 Amp. TP MCB |
| 1329 | Boundry WallContsruction of Boundry wall as per drawing with all complete. As per direction of Engineer In Charge |
| 1330 | EXTERNAL ELECTRIFICATION & LANDSCAPE LIGHTINGSupply & Fixingof’ 5mtr long Antique designed pole with castaluminium/ironbasewithgalvanized steelpipeand decorativetoppaintedwithprimerthenpaintedwithdull finished polyurethane paint fitted with MCB and connector withdecorativebracketsinglearmformountingof1nos drop down lantern with body made out ofspun aluminium and fitted with poly carbonate diffuser in 110W with built in surge protector and lumn output>110lmn/watt. Design as perArchitectincharge. (Make-Twinklelite/wipro/K Lite/ Luster) |
| 1331 | Supplying Testing & Installation of Led Flood Light Luminaire50W PhilipsMakeModel-BVP140Led50 CW PSU WH/ Wipro/ Luster etc all complete of directionof engineer in charge. |
| 1332 | Supplying Testing & Installation ofLed Flood Light Luminaire 100WV Philips Make Model- BVP 142 Led 100 CW PSU WH / Wipro/ Lusteretc all complete of direction of engineer in charge. |
| 1333 | Supply and fixing of decorative16 Watt LEDbollard luminaire with driver set confirming to IP 65 protection complete in all respect. |
| 1334 | Earthingwithcopperearthplate 600mm X600mm X 3 mmthickincludingaccessories,andprovidingmasonry enclosure with cover plate having locking arrangement and wateringpipeof2.7metrelongetc.withcharcoal/cokeand salt as required |
| 1335 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 1336 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metrebelowgroundasstripearthelectrode,including connection/terminatingwithnut,bolt,spring,washeretc. as required. (Jointing shall be done by overlapping and with 2 sets of brassn nut bolt & spring washer spaced at 50mm) |
| 1337 | Supply and layingofaluminium conductorPVCinsulated armouredservedsheathedcables1100Voltsgradeata depth of 750 mm below ground level over a cushion of 75mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S.clampsetc.ofsuitablesizeorasdirectedby the Engineer-Incharge ,complete in all respect. The armouring ofthecableshallbeproperlyconnectedwiththeearth conductor by clamps etc.6.00 Sqmm 4 Core |
| 1338 | 25.00 Sqmm 3.5 Core |
| 1339 | 70.00 Sqmm 3.5 Core |
| 1340 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect.40 A TPN |
| 1341 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench,complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 1342 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 1343 | LANDSCAPE & HORTICULTUREProvidingandstackingofBottlepalmofht.270-300 cm bottom girth 40-50cm well developed in big HDPE bags as per diection of the officer-in-charge. |
| 1344 | ProvidingandstackingofFicusbenjamina(green)of height150-165cm.,bushywithhealthybranchesand lush green foliage in big size HDPE bags as perdirection of the officer-in-charge. |
| 1345 | Providing and stacking of Ficus bengalensis krishna of height 75-90 cm., multibranched in earthen pots of size 30 cm as per direction of the officer-in-charge |
| 1346 | ProvidingandstackingofTectonagrandis(Teak)of height 150-165 cm. in big polybags of size 25 cm as perdirection of the officer-in-charge. |
| 1347 | ProvidingandstackingofWashingtoniafilifeapalm stem ht. 90-105cm with6-7healthy leaveslushgreen leaveswelldevelopedinbigsizeHDPEBagsasperdirection of the officer-in-charge. |
| 1348 | Providing and Displaying Sunflower hybrid well developed 15 to 20 cm ht. with fresh & healthy foliage at blooming stage in 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge. |
| 1349 | Providing and Displaying Creeper Rose variety 3 to 4 healthy branch 60 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer-in-charge. |
| 1350 | Providing and Displaying Standard Rose (H.T. variety) 3 to 4 healthy branch 90 cm and above ht. well developed with one and above flowers in 25 Earthen Pot, as per direction of the officer-in-charge. |
| 1351 | Providing and Displaying Bamboo Buddha vally variety with umbrella shape having 120 to 135 ht. with fresh & healthyfoliagewelldevelopedin40cmCementpot multy branch,bushy asperdirectionoftheofficer-in- charge. |
| 1352 | Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per directionof the officer-in-charge. |
| 1353 | Providing and stacking of Plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. |
| 1354 | Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushty shape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & asper direction of the officer-in-charge.. |
| 1355 | Trenchinginordinarysoiluptorequireddepth including removal and stacking of serviceable materialsandthendisposingofasdirectedand spreadingearth&neatly levelling,breakingclods etc.andmakingthetrenchedareawithdesigned mounds,pathsandsittingspacesetc.toproper levelsbyfillingwithearthorearthmixedwith manureandproperlywateringcompleteworkin required topography as per drawing &specifications. |
| 1356 | Supplying and stacking of good earth at site including royalty but including carriage1km (earth measusredinstackswillbereducedby20%for |
| 1357 | Supplying andstacking atsitedumpmanure from approved source,includingcarriageupto1km (manure measured in stacks will be reduced by8%for payment) |
| 1358 | Mixing earth and manure in specified proportion oras directed. |
| 1359 | Rough dressing the trenched ground includingbreaking the clods. |
| 1360 | Fine dressing the ground |
| 1361 | Spreadingof mixedgoodearthandmanurein specified proportions as aboveand inrequiredthickness. |
| 1362 | Uprooting weeds from the trenched area after 10 to15 days after flooding with water including disposal of uprooted vegetation. |
| 1363 | Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness on existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface withlightrollermakethesurfacesmoothenand light watering the same, as per direction of officerin charge |
| 1364 | Preparation of mounds of various size and shape by availableexcavated/suppliedearthinlayersnot exceeding 20 cm in depth, breaking clods, watering of nos layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge. |
| 1365 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering |
| 1366 | TREMIX PARKINGExcavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 1367 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 1368 | Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete. |
| 1369 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 1370 | Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete. |
| 1371 | Mildsteel or ironinplainworksuchas reinforcedconcrete orreinforced ,brick work (when not includedin anover all rates )wrought to required shapeas necessary including bendingforproper completion of theworkand includingsupplyof steelitswastage bendhooksand authorised overlapping shallbe measured upto floor two level. |
| 1372 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 1373 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of jointsexcept at sharp curve shall not to more than 5mm), including making drainage opening whereverrequired complete etc. as per direction of Engineer- in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 1374 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 1375 | DrainEarth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil |
| 1376 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominalsize) |
| 1377 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cementcontent, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Concrete of M25 grade with minimum cement content of 330 kg /cum All works above plinth level upto floor V level |
| 1378 | As in item 4 above but forslabs |
| 1379 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-MechanicallyTreated bars |
| 1380 | RAIN WATER HARVESTING PITSEarthworkinexcavationbymechanical means (Hydraulic excavator) / manual meansinfoundationtrenchesordrains (notexceeding1.5minwidthor10sqm onplan),includingdressingofsidesand ramming of bottoms, lift upto 1.5 m, includinggettingouttheexcavatedsoil anddisposalofsurplusexcavatedsoilas directed, within a lead of 50 m.All kinds of soil |
| 1381 | Brick work with common burnt clay F.P.S. (nonmodular)bricksofclassdesignation7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cementmortar1:6(1cement:6coarsesand) |
| 1382 | CEMENTPLASTERWITHAFLOATINGCOAT OF NEAT CEMENT12mmcementplasterfinished withafloating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand) |
| 1383 | Reinforcedcementconcreteworkin beams, suspended floors, roofs having slopeupto15°landings,balconies, shelves,chajjas,lintels,bands,plain window sills, staircases and spiral stair casesaboveplinthleveluptofloorfive level, excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3(1cement:1.5coarsesand (zone-III):3gradedstoneaggregate20 mm nominal size). RCC(1cement:1.5corasesand:3stoneaggregate) |
| 1384 | FORM WORKCenteringandshutteringincluding strutting, propping etc.and removal of form for all heights :Centeringandshutteringincluding strutting, propping etc.and removal of form for all heights : Suspended floors, roofs, landings,balconies and access platform |
| 1385 | STEEL REINFORCEMENTSteel reinforcement for R.C.C.work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. Hot rolled deformed bars |
| 1386 | Boring/drillingborewellofrequireddia forcasing/strainerpipe,bysuitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/borelog,includinghire&running charges of all equipments, tools,plants & machineriesrequiredforthejob,all completeasperdirectionofEngineer-in- charge,upto90metredepthbelow ground level.All types of soil300mm dia |
| 1387 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM)pipeofrequireddia,conformingto IS: 12818, including required hire and labourcharges,fittings&accessoriesetc. allcomplete,foralldepths,asper direction of Engineer -in-charge.150 mm nominal size dia |
| 1388 | Supplying, filling, spreading & leveling stonebouldersofsizerange5cmto20 cm,inrechargepit, inthe required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 1389 | Supplying, filling, spreading & leveling gravelsofsizerange5mmto10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 1390 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all completeasperdirectionofEngineer-incharge |
| 1391 | Gravel packing in tubewell construction in accordancewithIS:4097,including providinggravelfine/medium/coarse,in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 1392 | ProvidingandfixingM.S.clampof required dia to the top of casing/ housing pipeoftubewellasperIS:2800(partI), includingnecessarybolts&nutsof required size complete.150 mm clamp |
| 1393 | Providing and fixing Bail plug/ Bottom plug of required dia to thebottomofpipeassemblyoftubewellas per IS:2800 (part I).150mm dia |
| 1394 | Providing,fixinginpositionofISImarked UVstabilizedUPVCpipes forventing, Type-B as per IS : 13592 suitable for rubberringjointsforverticalpipesand solvent cement joints for horizontal pipes, includingallneccessaryspecialsand fittings (Make : Finalex/ Astral / Ashirwad) 75mmdia(WallThickness-3.2to3.8mm) |
| 1395 | Providingandfixinginpositionpre-castR.C.C. manhole cover andframe of required shape and approved quality Rectangularshape600x450mminternaldimensions |
| 1396 | Providingorangecoloursafetyfootrest of minimum 6 mm thick plastic encapsulatedasperIS:10910,on12mm dia. Steel bar conforming to IS:1786, having minimum cross section as 23mm x 25mmandoverallminimumlength263 mm and width as 165 mm with minimum112 mm space between protruded leg having 2 mm tread on top surface by ribbingorchequeringbesidesnecessary andadequatedanchoringprojectionson taillengthon138mmasperstandard drawingandsuitabletowithstandthe bendtestandchemicalresistancetestas per spaecifications and having manufacture\"spermanentidentification mark to be visible even after fixing, includingfixinginmanholeswith 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate20mmnominalsize)complete as per design. |
| 1397 | DG SET, SOLER PLANT,CCTV AND VRV/VRF SYSTEM ACSupplying, installation, testing and commissioning of silent type DG sets, AMF panel, bus ducting/ cables from DG sets to. essential panel, synchronizing panel where réquired, DG set enclosure room sound insulation/ventilation/smoke exhaust as required, earthing of DG set system, control cabling, fuel tank/piping, DG set exhaust piping/ exhaust chimney as per CPCB norms, civil works connected with DG sets including foundation as required. |
| 1398 | Supplying, installation, testing and commissioning of grid interactive roof Top solar photo voltaic power generation system including space frame |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail