Tender For Improvement Of Electrical Installations In Nicu At Mrs Glm Hospital Under Cspz, Delhi-Delhi

Tender Notice

52148827
Tender For Improvement Of Electrical Installations In Nicu At Mrs Glm Hospital Under Cspz
Tender
Indian
Delhi
Delhi
12-11-2025

Tender Details

Tender For Improvement Of Electrical Installations In Nicu At Mrs Glm Hospital Under Cspz; 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. (a) Group C 2 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required Group C 3 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 4 b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 5 c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 6 d) 4 X 4 sq.mm + 2 X 4 sq.mm earth wire 7 e) 4 X 6 sq.mm + 2X 6 sq.mm earth wire 8 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 15/16 amp switch 9 b) 3 pin 5/6 amp socket outlet 10 c) 6 pin 15/16 amp socket outlet 11 d) 5/6 Amps switch 12 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 13 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. (a) 3 Module (100mmX75mm) 14 b) 4 Module (125mm X 75 mm) 15 c) 6 Module (200mmX75mm) 16 d) 8 Module (125mm X 125mm) 17 e) 12 Module (200mm X 150mm) 18 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 6 way (4 + 18), Double door 19 b) 8 way (4+24), Double door 20 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single Pole 21 Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps C curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 22 Laying & fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the on cable tray as reqd. (a) Above 35 sq.mm and upto 95 sq.mm (clamped with 25X3mm MS Flat Clamp) 23 Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required.(a) Upto 35 sq. mm (clamped with 1mm thick saddle) 24 SITC of metal clad, powder coated, compartmentalized cubical panel board as per CPWD electrical specifications including insulated aluminum bus bars, supports, interconnection, erection of switchgears with depth 30 cm to 60 cm and making provisions for termination of incoming/ outgoing cables/ bus ducting and making foundation etc as required. (Suitable for 400 Amp TP & N) 25 Providing & Fixing following rating and breaking capacity MCCB in the existing cubical panel board including drilling the hole in cubical panel making the connection etc. as required. (a) 200 Amp, 25KA, TPMCCB 26 (b) 250 Amp, 25KA, TPMCCB 27 Supply of XLPE insulated PVC sheathed Al. Cond. Armoured cable of 1.1kV grade conforming to IS-7098 Part-I of following size:-4 x 50 sqmm 28 SITC of wall mounted fan 400mm sweep rated voltage 220-230 V AC ratedfrequency 50Hz speed 1280-1350 RPM with desired colour 29 Supply of 12 (300 mm)sweep 1400 rpm exhaust fan Fresh Air Type complete with shutter blades etc. as required. 30 Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit,safety rope, copper winding, steel/Al body Power Factor not less than 0.9,Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS :374-2019), THD (Total Harmonic Distortion) less than 10%, remote(preferably mobile app based) for speed control and all remainingaccessories including safety pin, nut bolts, washers, temperature rise=75degree C (max.), insulation resistance more than 2 mega ohm, suitable for230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan i/c external connection with 1.5 sw. mm FLRS/HFFR PVC insulated copper conductor single core cable and earthing etc.as req. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min(Minimum) 31 Supplying, installation, Testing & Commissioning of LED surface mountedBatten light of following body material and construction as per IS : 10322 withdriver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short &Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flickerfree (flicker should be below 5 %), life time (LED,Driver & electrical circuitry),of minimum 50000 Burning Hours with , 70% of initial Lumenmaintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching)<3, Maximum power consumption should not more than the specified ratingand Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screenprinting on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy>=105 ,120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast/ extruded aluminum body (thickness.1.20mm) 18-22 Watt 32 Supplying and fixing following rating, four pole, 415 V, isolatorin the existing MCB DB complete with connections, testing andcommissioning etc. as required. (a) 63 Amp 33 Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator) (a) 12 way, Double door 34 Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator) (a)8 way, Double door 35 (b) 12 way, Double door 36 Supplying and fixing following rating, double pole, 240 V,isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required. 63 Amp

Key Value

Document Fees
INR 590 /-
Tender Value
INR 5.81 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail