Construction Of Machinery Shed 91.00 Sqm- 1 Construction Of Machinery Shed 91.00SQM 2 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means....(INo21-02, PgNo 153) (STATE SSR ) Item Spec: (Bd.A.1 Page No. 259) 3 Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Mean....(INo 21-06, PgNo 153) (STATE SSR ) Item Spec: (Bd.A.2 Page No. 259) 4 Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granitel quartzitel gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc)....(INo24-01, PgNo 226) ( STATE SSR ) Item Spec: (Bd. E. 1 Page No. 287) 5 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc 6 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks compacting and roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) 7 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc).... (INo25-50, PgNo 234) (STATE SSR ) Item Spec: (Bd.F.6 Page No. 300 and B.7, Page No.38) 8 Providing and casting in situ cement concrete M20 of trap/Granite / quartzite/ gneiss metal for R.C.C. slabs and landings canopy as per detailed designs and drawings including centering, formwork, cover blocks compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).With fully automatic micro processor based PLC with SCADA enabled reversible drum type concrete mixer With natural sand.Bd.F.8 Page No.302 and B.7,Page No.38 9 Providing and laying in situ cement concrete M-20 with tremix treatment for 100 mm thickness for flooring with groove cutting of 4 mm wide and 20 mm deep with necessary refilling with bitumenetc. complete.SSR 2019-20 Item No. 33.30. 10 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, linteis pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bass, binding with wires or tack welding and supporting as required complete ..... (INo26-33, PgNo 245) (STATE SSR ) Item Spec: (Bd.F.17, Page No. 306) 11 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. 12 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. CompleteBd.G.5 Page No.315 13 Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15cm, to 20cm, including watering and compaction etc. complete.....(IN021-37, PgNo 201) (STATE SSR ) Item Spec. (Bd. A.11 Page No. 283) 14 Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. Complete 15 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete....(INo32-04. PgNo 268) ( STATE SSR ) Item Spec: (Bd. L.2 Page No. 368) 16 Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.....(INo32-11, PgNo 269) ( STATE SSR ) Item Spec: (Bd.L.7 Page No. 369) 17 Providing & applying washable oil-bound distemper of approved colour and shade to old & new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete.....(INo36-11, PgNo 291) (STATE SSR ) Item Spec: (Bd.P.5 Page No. 413 18 Providing and applying three coats of water proof cement paint of approved manufacture and of approved colour to oldplastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete.Spec.No.: Bd.O.8/Page No.406 19 Providing structural steel work in trusses, other similar trussed purlins and members with allbracing, gusset plates etc. as per detailed designs and drawings or as directed includingcutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ weldedconnection and one coat of anticorrosive paint and over it 2 coats of oil painting approvedquality and shade etc. complete 20 Providing and fixing colour coated Zincalume (R) AZ150 ( min 150 gms/sq.mt. Total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness (BMT) (0.5 mm TCT), Hi-strength steel with min.550 Mpa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) váth COLORBOND (R) steel quality with thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10coat on back surface. Profile sheet shall have nom. 950-1050 mm width and nominal 25-30 mm deep ribs with subtle square fluting in shall be designed for anti-capillary groove. & return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. Fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. Complete. (weight of profile 4.52 kg/sqm)..(As directed by Engineer in charge.) 21 Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angie section fitted with Sliding bolts and handles for both sides, deep M. S. channel section of respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 6248-1979) (Without mechanical gear)....(INo39-24 , PgNo 318) ( STATE SSR) Item Spec: (Bd.T.55, Page No. 510) 22 Providing and fixing steel ventilator fully glazed partly fixed as per detailed drawing without hot dip zinc coating includingfabricating glazing with plain / obscured glass panes and approved type and quality and iron oxidized fixtures andfastening oil paint 2 coats etc. complete.Bd. T. 53, Page No. 509 & As directed by Engineer in charge. 23 ROYALTY 24 Sand 25 Rubble& Murum 26 MATERIALS LAB TESTS 27 Cement :- Fineness,Standard Consistency, Setting Time (Initial & Final ), Compressive strength, Soundness 28 M10 i)Concrete cube compressive strength (Set of 3 Cubes) 29 M20-i)Concrete Mix Design (With all Tests on basic materials) ii)Concrete cube compressive strength (Set of 3 Cubes) 30 Sand-Fineness Modulus,Silt Content 31 BRICKS-Water Absorption (Set of 5 Bricks), Compressive Strength( Set of 5 Bricks), Efflorescence (Set of 5 Bricks). 32 Murum In PlinthPlasticity Index 33 STEEL :- Tensile strength Yield stress, ultimate tensile stress. %elongation, weight per running meter,Bend/Rebend test. (Set of 3 Bars)UP to 16mm 34 Crushed metal for concrete :- i)Water absorption, Specific gravity,Impact value,Crushing value 35 ESHS Compliance 36 Management Strategies andImplementation Plan (MSIP) to manage Environmental, Social , Health and Safety (ESHS) Risk and ESHS Code of Conduct