Tender For Repair Work Of Residential Type Iv Buildings Part I - Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes inCement mortar 1:6 (1 cement : 4 coarse sand) DSR no 6.4.2 2 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1 :2:4 (1 cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)DSR 4.1.3 3 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete uptoor above plinth level. DSR 5.22.1 4 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.DSR 15.56 5 12 mm cement plaster of mix :DSR 13.1.2 1:6 (1 cement: 6 fine sand) DSR 6 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc.complete DSR No 13.88 7 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surfac eto prepare the surface even and smooth complete. DSR 13.80 8 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. DSR 13.85.3 9 Distempering with 1st quality acrylic distemper (ready mixed) having VOC(Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour DSR 13.81.1 (two coats) 10 Finishing walls with water proofing cement paint of required shade : DSR 13.109.2 11 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade DSR 13.112.1 12 Cement concrete flooring 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement sluny, but excluding the cost of nosing of steps etc. complete. DSR 11.3.1 40 mm thick with 20 mm nominal size stone aggregate 13 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1 :4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. DSR 11.37 14 Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1 :4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. DSR 11.41.2 15 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platfonns, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1 :4 (1 cement: 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing of edges to give high gloss finish etc. complete at all levels.DSR 8.2.2 Granite stone slab of colour black, Cherry/Ruby red 16 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. DSR 10.25.1 17 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. D.S.R.9.135.1 18 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: D.S.R 14.5.1 19 Renewing glass panes, with wooden fillets wherever necessary:D.S.R 14.6.1 20 Supplying and fixing new wooden fillets wherever necessary: D.S.R 14.8.1 21 Renewal of old putty of glass panes (length) metre D.S.R 14.9 22 Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as perthe direction of the Engineer-in-charge.DSR 14.85 23 Providing and fixing ISi marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. DSR 9.21.1 35 mm thick including ISi marked Stainless Steel butt hingeswith necessary screws 24 Applying priming coat: With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood DSR 13.50.2 25 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : DSR 13.99 26 Providing and fixing ISi marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) DSR 9.62.1 27 Providing and fixing ISi marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) DSR 9.63 28 Providing and fixing ISi marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) DSR 9.66.1 29 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,DSR 12.41 (110 mm pvc pipe 30 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.DSR 18.7 (15 mm pvc pipe) 31 Providing and fixing brass bib cock of approved quality.DSR 18.15 32 Providing and fixing brass stop cock of approved quality .D.S.R.18.16 33 Providing and fixing uplasticised PVC connection pipe with brass unions : .D.S.R.18.21.1 34 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : DSR 17.25.2 35 Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete. DSR 17.28.1 36 Dismantling W.C. Pan of all sizes including disposal of dismantled materials including malba all complete as per directions of Engineer-in-Charge. DSR 14.82 37 Providing and fixing white vitreous china water closet squatting pan (Indian type) :17.13.2 Orissa pattern W.C. pan of size 580x440 mm DSR17.13 38 Providing and fixing white vitreous china pedestal type (European type/wash down type) water closet pan. DSR 17.15 39 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. DSR 17.16A 40 Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittingsand fixtures complete. DSR 17.18 41 Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. DSR 17.22 42 Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace includingshifting at ground level as per direction of Engineer-in-charge. DSR 14.79 43 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.D.S.R.18.48