Tender For Repair/ Maintenance To Internal Electrification, Fitting Fixture, Unsv Mcb’S, Building Earthing And Other Misc E/M Works Including Attending Day To Day E/M Complaints In Md & Otm Accns At Aftc, 2 Dc Area & Afs Jalahalli.;  1 Repair, maintenance and making the continuity of supply after rectifying the defects of the electrical items such as light point, fan point, call bell point, socket point 5A/15A, switches, sockets, regulator, lamp holder, brackets, bell, buzzer, push button, batten, ceiling rose, pendent, any type of MCBs, DBs any type of light fixtures, any type of lamp, ceiling fan, exhuast fan, geyser, capacitor, replacement of fuse wires and all elcectrical accessories in day to day/door to door maintenance including reconnection with S&Fsmall pieces of elctrical cable of size upto 10 Sqmm single core and length not exceeding 0.50m, complete all as specified and as directed.Note:(i)Any major items required to be repaired/replaced will be measured and paid under relevant items as supply only.(ii)Cost of labour for replacement/ attending five complaints in same building number will be treated as one job  2 Note for item No 1:- (a)The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be producedto Engr-in-Charge before commencement of work.  3 (b) All bldg light complaints including service connection, sub main & internal electric for entire OTM and Md accn at AFTC, 2 DC Area and AF Stn Jalahalli shall be attended  4 (c) Record of complaints/complaint slip showing qtr No, bldgs No, nature of job supported with users signature shall be prepared as per format as directed by Engr-in-charge & will be deposited to concerned JE E/M within 24 hrs.  5 (d)All sort of petty T&P items such as PVC insulation tape, ladder, galvanised screws, nuts, bolts, washers etc. required to accomplish the job shall be provided by the contractor without any extra cost to deptt.  6 (e)In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent complaints, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.  7 (f)The penalty shall be applicable to the contractor if the delay is noticed by the Engr-in-Cahrge more than twelve hrs after handing over works of urgent/ routine nature to the contractor. The Engr-in-Chargeshall handover the slip containing specification of work to the contractor by lodging the time and signature of contractor shall be obtained on slip.The contractor shall attend the complaint immediately and shall report to Engr-in-Charge with in 12 hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive.If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Chargeand the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay than penalty at the rate of Rs 50/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other than the condition 67 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.  8 (g) The decision of the Accepting Officer in this regard shall be final and binding.  9 Supply only switch piano flush type 5 Amps240 volts single pole one way, complete all as specified and directed. Make : Anchor, Havells, L&T, Indoasian  10 Supply only switch piano flush type 5 Amps240 volts single pole two way, complete all as specified and directed. Make :Anchor, Havells, L&T, Indoasian  11 Supply only switch piano flush type 15 Amps240 volts single pole one way, complete all as specified and directed. Make : Anchor, Havells, L&T, Indoasian  12 Supply only shuttered socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed Make :Anchor, Havells, L&T, Indoasian  13 Supply only shuttered socket outlet 2 in 1, 5 pin, 5 and 15 Amps, complete all as specified and directed Make :Anchor, Havells, L&T, Indoasian  14 Supply only switch socket combination out let 3 pin 5 Amps, flush type, complete all as specified and directed. Make :Anchor/Havells/L&T/ Indoasian  15 Supply only switch socket combination out let 2 in 1, 6 pin 5 and 15 Amps, flush type, complete all as specified and directed.Make :Anchor/Havells/L&T/ Indoasian  16 Supply only lamp holder, insulated body, cord grip pattern SP 230 volt, complete all as specified and as directed.  17 Supply only 7 watt LED lamp, complete all as specified and directed. Make : Philips/ Bajaj/ Crompton  18 Supply only rigid, non-metalic, PVC conduit pipe (ISI marked), 32 mm bore, including bends, saddles, accessories, complete all as specified and as directed. Make : Avon plast/ supreme/ Diplast  19 Supply onlyPVC insulated FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 4 Sqmmof single core, complete all as spcified and directed. Make : Havells/ Polycab/ Plaza.  20 Supply only 2.5 mfd condensor for ceiling fan, complete all as specified and directed. Make : Epcos/ Asian/ Tyton  21 Supply only PVC gang box suitable for 15Amp switch socket , complete all as specified and directed . Make. Cona/L&T/Anchor  22 Supply only plug top 3 pin 5 AmpsAC 230 volts, complete all as specified and directed. Make : Havells/ Cona/ Plaza  23 Supply onlyPVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 6 Sqmm single core, complete all as spcified and directed. Make : Havells/ Polycab/ Plaza.  24 Supply only Ceiling rose 3 phase/ PVC/ Polycarbonate, isolated body(ISI marked), complete all as specified and directed  25 Supply only electronic LED driver 36/40 W suitable for 2 x 2 ceiling light indoor fitting of make Philips/ crompton/ Bajaj, complete all as specified and directed .  26 Supply onlysinglepole MCB 6 to 32 Amps, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996, completeall as specified and directed.Make : Legrand/ L&T/ Indo Asian  27 Supply only rigid, non-metalic, PVC conduit pipe, ISI marked, 25 mm bore, including bends, saddles, accessories, complete all as specified and as directed. Make : Avon plast/ Supreme/ Diplast  28 Supply only electronicfan regulator modular type 230 volts, step type socket type, hum free 100/240 watt, complete all as specified and directed.Make :Havells / Anchor/ Crabtree.  29 Supply only PVC Casing & Cappingof 15 mm (width), complete all as specified and directed.  30 Supply only SPN MCB 40 Amp, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996, all as specified and directed. Make : Legrand/ L&T/ Indo Asian  31 Supply onlyPVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 1.5 Sqmm of 3 core, complete all as spcified and directed. Make : Havells/ Polycab/ Plaza.  32 Supply only switch socket combination outlet 3 in 1/ 3 pin 3 and 5 Amps flush type with box, complete all as specified and directed.  33 Supply only switch socket combination outlet 5 in 1/ 5 pin 5 and 15 Amps flush type with box, complete all as specified and directed.  34 Supply only insulation tape 25 mm width 10m long (ISI Marked), complete all as specified and directed.  35 Supply only electronic LED driver 10/12 W suitable for round ceiling light indoor fitting of make Philips/ crompton/ Bajaj, complete all as specified and directed .  36 Supply only PVC gang box suitable for 05 Amp switch socket, complete all as specified and directed . Make. Cona/L&T/Anchor  37 Supply only PVC Casing & Capping of 25 mm (width), complete all as specified and directed.  38 Supply onlymodular PVC box 2 module, complete all as specified and directed. Make : Legrand /Crabtree/ Anchor/Indoasian  39 Supply onlyTPN, MCB 40 to 63 Amp, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacitycomplete conforming to IS 8828 of 1996, all as specified Make : Legrand/ L&T/ Indo Asian  40 Supply only metal clad switch socket single pole and neutral enclosure withtwo pin and earth plug and socket complete with one single pole MCB 20A concealed in walls. Make : Legrand/ L&T/ Indo Asian  41 Supply only electronicfan regulator 230 volts, step type socket type, hum free 100/240 watt , complete all as specified and directedMake :Havells / Anchor/ crabtree/Indoasian  42 Supply onlymodular PVC box 3module, complete all as specified and directed. Make : Legrand /Crabtree/ Anchor  43 Supply only plug top 3 pin 15 AmpsAC 230 volts, complete all as specified and directed. Make : Havells/ Cona/ Plaza  44 Supply onlymodular switch1 way 6 Amp.1 module , complete all as specified and directed.. Make : Legrand/ Crab tree/ Anchor/ Indoasian  45 Supply onlymodular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.. Make : Legrand/ Crab tree/ Anchor/ Indoasian  46 Supply onlymodular switch1 way 16 Amp.1 module, complete all as specified and directed.. Make : Legrand/ Crab tree/ Anchor/ Indoasian  47 Supply only modular Socket, 16A - 3/5 pin combined 2 module, complete all as specified and directed.. Make : Legrand/ Crab tree/ Anchor/Indoasian  48 Supply onlymodular white cover plate with frame, 3 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian  49 Supply only modular white cover plate with frame, 4 module, complete all as specified and directed.. Make : Legrand /Crabtree/ Anchor/Indoasian  50 Supply onlymodular white cover plate with frame, 6 module, complete all as specified and directed.. Make : Legrand /Crabtree/ Anchor/Indoasian  51 Supply onlymodular white cover plate with frame, 8 module, complete all as specified and directed.. Make : Legrand /Crabtree/ Anchor/Indoasian  52 Supply onlymodular white cover plate with frame,12 module, complete all as specified and directed.. Make : Legrand/ Crabtree/ Anchor/Indoasian  53 Supply only TPN, MCB 20 to 32 Amp, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacitycomplete conforming to IS 8828 of 1996, all as specified Make : Legrand/ L&T/ Indo Asian  54 Supply only electric bell, AC 230 volt, single pole Ding Dong type complete all as specified and directed. Make :Anchor/Havells/L&T/ Indoasian  55 Supply only 4 mfd condensor for exhaust fan, complete all as specified and directed. Make : Epcos/ Asian/ Tyton  56 Supply only PVC Casing & Capping of 20 mm (width), complete all as specified and directed.  57 Supply onlymodular PVC box 4 module, complete all as specified and directed. Make : Legrand /Crabtree/ Anchor/Indoasian  58 Supply only bell push, piono type 5/6 Amp, complete all as specified and directed.Make : Anchor/ Cona/ Havells/ Indoasian  59 Supply onlyPVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 2.5 Sqmm 3 core,complete all as spcified and directed. Make : Havells/ Polycab/ Plaza  60 S & F in repairs 3.0 mm thick hylum sheetof size 4x 4 forfixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete all as specified and directed.  61 S & F in repairs 3.0 mm thick hylum sheetof size 6x 8 forfixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete all as specified and directed.  62 S & F in repairs Modular flush metal box 1/2 module in the existing wall complete all as directed. Note : Concealed the Modular flush metal box on wall all including making good and matching with existing surface included in the quoted rate.  63 S & F in repairs Modular flush metal box 3 module in the existing wall for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with screws complete all as specified and directed. Note : Concealed the Modular flush metal box on wall including making good and matching with existing surface included in the quoted rate.  64 S & F in repairs Modular flush PVC box 1/2 module in the existing wall for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with screwscomplete all as directed.  65 S & F in repairs Modular flush PVC box 3 module in the existing wall for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with screwscomplete all as specified and directed.  66 S&F in repairof new PVC conduit medium grade of size 25mm on wall /roofwith help of screw and GI shaddle including fixing of existingserviceable copper /aluminium conductorand all fitting fixture such as Tee, Elbow and lapping, completeall as specified and as directed. Make : Supreme/Diplast/Avon plast  67 S&F as in repair PVC casing capping medium grade of size 32 mm on wall /roofwith help of screw including serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping,completeall as specified and as directed. Make: Polycab/ Modi/ Presto Plast  68 M&L for Sub main wiring with PVC insulated unsheathedFRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 Sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 4 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size.Note: (a)2 runs of 4 Sqmm cable along with onerun of 4 Sqmm cable for earth conductor shall be measured as one length.Make:- Havells/ Polycab/ Plaza.  69 S&F in replacement factory madepowder coated distribution board SPN 12 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian  70 S & F MCB in repair ofSPN 240 volts 63 Amps including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian  71 Supply and Fixin repair ofsurface mounted Square/Roundfor LED 18 Watt downlights made of extruded Aluminium housing and high power LED light source withDriver clear diffuser with separate electronic driver with complete accessories all as specified and directed .Make : Philips/ Bajaj/ CG/Havells.  72 Supply & Fixing in replacement of electronic LED driver 18/20 W suitable for round ceiling light indoor fitting of make Philips/ crompton/ Bajaj, complete all as specified and directed .  73 Supply and Fix in repair switch piano flush type 5 Amps240 volts single pole one way, complete all as specified and directed. Make : Anchor/Havells/L&T/ Indoasian  74 Supply and Fix in repair shuttered socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian  75 Supply and Fix in repair shuttered switch socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian  76 Supply and Fix in repair shuttered switch socket outlet 2 in 1, 5 pin, 5 and 15 Amps, complete all as specified and directed. Make : Anchor/Havells/L&T/ Indoasian  77 S & F in repairs Modular flush metal box 4 module in the existing wall for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with screws complete all as specified and directed. Note : Concealed the Modular flush metal box on wall all including making good and matching with existing surface included in the quoted rate.  78 S & F in repairs Modular flush metal box 6 module in the existing wall for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with screws complete all as specified and directed. Note : Concealed the Modular flush metal box on wall all including making good and matching with existing surface included in the quoted rate.  79 S & F in repairs Modular flush PVC box 4 module in the existing wall for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with screws complete all as specified and directed.  80 S & F in repairs Modular flush PVC box 6 module in the existing wall for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with screws complete all as specified and directed.  81 M&L for cutting of hole through stone wall with the help of Core cutting machineincluding providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core,rubbish not exceeding 50 mtrs including fixing of exhaust fan of size 250-450 mm all as specified and as directed.  82 Supply and fixingExhaust fan250 mm sweep 230/ 240 volt AC single phase PVC body1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No. with synthetic enamel paint all specified and directed.Make : Havells/Bajaj/ Orient/USHA.Note:-Old Unserviceable Exhaust fan shall be deposited by the contractor to MES store yard.  83 M&L in repairfor stainless steel wire cloth 0.63 mm dia of wire and average width of aperture 1:40 mm for covering of exhaust fan hole in wall of size 450 mm X450 mm with PVC/woodenbeading fixed on wall including necessary fixing arrangement up to height 11 mtrcomplete all as specified and directed.Note : All safety measures shall be the responsibility of the contractor  84 S&F in repair of new PVC conduit medium grade of size 20 mm on wall /roofwith help of screw and GI shaddle including fixing of existingserviceable copper /alluminium conductorand all fitting fixture such as Tee, Elbow and lapping,completeall as specified and as directed. Make : Supreme/Diplast/Avon plast  85 S&F in repairs 36 W (WW/WH) LED surface mounted2x2 luminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) all as pecified and directedMake : Philips/ Bajaj/CG/Havells.  86 Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.  87 Taking down aluminium/copper point wiring & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete and making good the disturbed plaster surfaces of wall, floor, ceilingand painting 2 coat of white wash/distamber to match the existing surface, complete all as specified and directed.  88 M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn into and including concealedrigid non mettalic PVC conduit/casing caping medium grade not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including sunk in pressed steel chromium plated terminal boxes, concealed in wall/surface/roofs/floor/ceiling etc as per site requirement and making & maching the existing surface ) white bakelite sheet cover for mounting switches, Sockets, Fan regulators etc or modular cover plate with frame including sunken boxes suitableto fix modular cover plate with frame , concealed in wall and 1.5 sq mm multi stranded copper conductor cable as continuous earth wire drawn with wiring and connected to common earth dolly complete all as specified and directed for the following :- Make of wire: Polycab/Plaza/HavellsNote:Blanking plate,Modular cover plate ,Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely).  89 All as per item No. 88 here in before but for one light point/fan point controlled by one wayswitch.  90 All as per item No. 88here in before but for one light point controlled by twowayswitch.  91 All as per item No. 88here in before but for one bell point controlled by one bell push.  92 All as per item No. 88 here in before but for one 3 pin socket out 5 Ampon the same board  93 All as per item No. 88 here in before but for one switch socket outlet 3 pin 5 Amps on independent board  94 All as per Sl No 88 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor (FRLS) controlled by one 15A switch socket independently complete all as specified and directed.  95 Supply and Fix switch piano flush type 5 Amps240 volts single pole one way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian  96 Supply and Fix switch piano flush type 5 Amps240 volts single pole two way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian  97 Supply and Fix switch piano flush type 5 Amps240 volts bell push, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian  98 Supply and Fix shuttered socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian  99 Supply and Fix shuttered switch socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian  100 Supply and Fix shuttered socket outlet 2 in 1, 3 pin, 5 and 15 Amps, complete all as specified and directed.Make : Anchor/Havells/L&T/Indoasian  101 M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 Sqmm drawn through in and incl suitable size surface PVC Conduit/ existing concealed conduit and all accessories fixed to wall/floors along with 6 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size.Note: (a)2 runs of 6 Sqmm cable along with one run of 6 Sqmm cable for earth conductor shall be measured as one lengthMake:- Havells/ Polycab/ Plaza.  102 S&F in replacementfactory madepowder coated distribution board VTPN, 6 way double doorMCCB DB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as directed. Make : Indoasian/ Havells/ Legrand.  103 S&F in replacement distribution board MCCB four pole, 100 Amp ultimate breaking capacity 16 KAconforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian  104 Supply and Fixing in repairs of 4 feet surface mounted batten type luminaire , lumen output of 2000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability .The luminaire and driver shall be BIS approved, complete all as specified and directed.Make : Philips/ Bajaj / CG/Havells.  105 Supply & fix in repair decorative surfacemountedultra slim Square/Roundprofile 18 W LED(WW/WH) lighting fixture Square shape with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of18 Watt and includingcosidering material & labour forfixing ceiling hight upto 7.5 Mtr, complete all as per site requirementand directedMake : Philips/ Bajaj / CG/Havells.  106 S&F in replacementfactory madepowder coated distribution board TPN, 4 way double doorMCBDB includingbus bar, Neutral bar, standard DIN rail, earth bar including taking down unserviceable DBcomplete all as directed. Make : Indoasian/ Havells/ Legrand.  107 S & F in repair MCB single pole 240 volts 6 to 40 Amps complete including taking down unserviceable fitting complete all as specified and as directed. Make : Legrand/ L&T/ Indo Asian  108 Refixingexisting serviceable LED light fitting fixture any capacity and of any type complete with all accessories internally pre-wired and including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size after cleaning all dust etc. completeall as specified and as directed .  109 M&L for cutting of hole through brick wall with the help of Core cutting machineincluding providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core,rubbish not exceeding 50 mtrs including fixing of exhaust fan of size 250-450 mm all as specified and as directed.  110 Supply and fixingExhaust fan 300 mm sweep 230/ 240 volt AC single phase PVC body 1400 RPM including necessary nut, bolts / screws and taking down existing one, writing MES No. with synthetic enamel paint all specified and directed.Make : Havells/Bajaj/ Orient/USHA.Note:-Old Unserviceable Exhaust fan shall be deposited by the contractor to MES store yard without any extra cost to the deptt.  111 M&L forin repair louver made of steel suitable for 300 mm size exhaust fan, fixed on wall including necessary fixing arrengement up to height 11 mtrcomplete all as specified and directed.Note : All safety measures shall be the responsible of the contractor.  112 S&F in repairs LED bed side light /wall light/study lightenvironmentel friendly energy effcient of capacity3 W warm whiteetc,inbuilt drivercomplete with all accessories internally pre-wired swing type and including connecting up towith twin core twisted flexible copper conductor cable with suitable size complete all as directed . Make : Bajaj/ Philips / Wipro/CG  113 Supply & Fixing in replacement of electronic LED driver 2/3 W suitable for bed side light fitting as per site requirement complete all as specified and directed .  114 S & F in repairs 3.0 mm thick hylum sheetof size8x 8 forfixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete all as specified and directed.  115 S & F in repairs 3.0 mm thick hylum sheet of size 8x 12 forfixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete all as specified and directed.  116 S & F in repairs Modular flush metal box 8 module in the existing wall for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with screws complete all as specified and directed. Note : Concealed the Modular flush metal box on wall all including making good and matching with existing surface included in the quoted rate.  117 S & F in repairs Modular flush PVC box 8 module in the existing wall for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with screws complete all as specified and directed.  118 S & F in repairs Modular flush PVC box 12 module in the existing wall for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with screws complete all as specified and directed.  119 Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc 10 cm but not exc 20 cm girth complete all as specified and directed.  120 M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn through and including surface PVC conduit/existing concealed conduit/PVC casing-caping etc as per site requirement onwalls / roofs / floors / ceiling etc and including provision of 1.5 sqmm copper cable as earth continuity conductor and connected to common earth dolly with all fitting and fixing accessories including sunk in cast iron / pressed steel terminal boxes (duly painted with two coats of anti corrosive paint out side and two coats of aluminium paint inside ) with 3.0 mm thick hylum brand laminated white bakelite sheet cover for mounting switches, sockets, fans regulators etccomplete for the following :-Make of wire: Polycab/Plaza/HavellsNote: (a) Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely).  121 All as per item No. 120here in before but forOne light point/fan point controlled by one way 5 Amp switch.  122 All as per item No. 120here in before but forOne light point controlled by two way 5 Amp switch.  123 All as per item No. 120here in before but for one bell point controlled by one way bel push.  124 All as per item No. 120here in before but forOne 3 pin socket out let 5 Ampon the same board  125 All as per item No. 120here in before but for one switch socket outlet 3 pin 5 Amps on independent board  126 All as per item No. 120here in before but for Wiring with 4 Sqmm copper multistranded unsheathed cable and4 Sqmm copper cable (FRLS) for earth continuity conductor controlled by one 15A switch socket independently complete all as specified and directed.  127 Supply and Fixmodular switch1 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian  128 Supply and Fixmodular switch2 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor /Indoasian  129 Supply and Fixmodular switchbell push .1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor /Indoasian  130 Supply and Fixmodular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian  131 Supply and Fixmodular switch1 way 16 Amp.1 module, complete all as specified and directed. Make :Legrand/ Crabtree/ Anchor /Indoasian  132 Supply and Fix modular Socket, 16A - 3/5 pin combined 2 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian  133 Supply and fix White cover plate with frame,2/3 module  134 Supply and fix White cover plate with frame,4 module  135 Supply and fix White cover plate with frame,8 module  136 Supply and fix White cover plate with frame,6 module  137 Supply and fix White cover plate with frame,12 module  138 S & F ceiling rose 3 phase/ PVC/ Polycarbonate, isolated body(ISI marked) complete all as specified and directedMake : Anchor/Havells/L&T  139 S & Ffan regulator 120W,for ceiling fan complete all as specified and directed Make : Anchor/Havells/L&T  140 S & F2.5 mfd condensor for ceiling fan, complete all as specified and directed. Make : Epcos/ Asian/ Tyton  141 S & Felectric bell, AC 230 volt, single pole Ding Dong type complete all as specified and directed. Make :Anchor/Havells/L&T  142 S & F Modular fan regulator 120W, 2 Module for ceiling fan complete all as specified and directedMake : Legrand/ Crabtree/ Anchor  143 M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 Sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 6 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size.Note: (a)2 runs of 6 Sqmm cable along with one run of 6 Sqmm cable for earth conductor shall be measured as one lengthMake:- Havells/ Polycab/ Plaza.  144 S&F in replacementfactory madepowder coated distribution board VTPN, 4 way double doorMCCB DB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as directedMake : Indoasian/ Havells/ Legrand.  145 S&F in replacement on distribution board MCCB four pole, 63 Amp ultimate breaking capacity 16 KA conforming to IEC -61439-1, complete all as specified and directed.Make : Havells/ L&T/ Indoasian  146 Supply and Fixing in repairs of 2 feet surface mounted batten type luminaire , lumen output of 1000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability .The luminaire and driver shall be BIS approved, complete all as specified and directed.Make : Philips/ Bajaj / CG/Havells.  147 S & Fin replacement 9 watt LED lamp, complete all as specified and directed. Make : Philips/ Bajaj/ Crompton  148 S&F in replacement factory madepowder coated distribution board SPN 8 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar including taking down unserviceable DBconforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian  149 S & F MCB in repair and replacement ofSPN 240 volts 16 to 40 Amps including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian  150 Supply and fixing in repair building security/ LED street light fitting 36 Watt, 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal, management in multiple optics with IP 65/66 protection complete all as specified and directed. Make: Philips/Bajaj/CG  151 Supply and fix GI pipe 32 mm dia, medium grade for mounting bracket, bent to shape 1.5 meter length and fixing arrangement with two Nos ofclamps set, nut, bolts, washers, andincl taking down old unserviceable GI pipe complete all as specified and directed  152 Excavation in trenches not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth for laying of cables up to proper level and laying of pipelines etcinsoft/loose soil, complete all as specified and directed.  153 Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed.  154 Removing surplus excavated material (soil) not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point, complete all as specified and directed.  155 Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983, complete all as specified and directed.Note :- (i)Excavated approved soil shall be ribbed by using sieve to separate composite particles etc. as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness shall be considered for payment.  156 Material and labour for well burnt bricks ‘B’ class as mechanicalprotection to under ground cables laying with length of the bricks equal to the width of the trench, complete all as specified and directed.  157 Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earthwork, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :-The tenderer shall take into consideration for following points while quoting rate for this item andthe unit rate is deemed to be inclusive for :-(i) Earth work and excavation in any type of soil(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick ,complete all as specified and as directed.(iii) Removing excavated material out side MD land.(iv)Laying of any type/any bore of pipe in trenches including taking down existing unserviceable pipe. Supply of pipe shall be measured and paid separately(v)150 mm thickPCC 1:2:4 type B1 using 20mm graded stone aggregate as inroad to make good existing disturbed surfaces.  158 Supply only of GI pipe light grade for cable protection of size 50 mm bore with fittings, complete all as specified and directed.  159 Material and labour forBoring of holes under road, pavement hard standings by trenchless technology using ultra sound technique and necessary machine including supply of HDPE pipes upto 50 mm dia suitable for 0.4 Mpa working pressure, complete all as specified and directed.  160 Material and labour in repair for 3 ½ core 25 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian  161 Material and labour in repair for 4 core 16 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian  162 Material and labour in repair for 3 ½ core 35 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian  163 Material and labour in repair formaking straight through joint with suitablejointing kit consisting of water proof adhesivesfor UG cable of size 3.50 core 25 Sqmm to 35 Sqmm, complete all as specified and directed.  164 Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for thecable sizefrom 16Sqmmto 35 Sqmm 3.5 core of underground LT armoured cables.Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted.  165 Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS complaints & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure shall be above 200mm for air circulation & to minimize temp rise. Panel shall be fitted with one No.polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 150 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20 mm graded aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board of any size and description, reconnecting existing LT UG Cable with new panel board, complete all as specified and as directed :-  166 (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amp, 25 KA- 01 No. (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity40 Amp,10 KA- 04Nos(c) MCB SPNof 240 V of capacity 40 Amps 10 KA- 01No.(d) Multifunction Meter (V,I,PF) with suitable capacity of CTs- 01 No.(e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set(f) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).  167 M&L for Sub main wiring with PVC insulated unsheathedFRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 Sqmm drawn through in and incl suitable sizesurface PVC Conduit/ existing concealed conduit and all accessories fixed to wall/floors along with 4 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size.Note: (a)2 runs of 4 Sqmm cable along with onerun of 4 Sqmm cable for earth conductor shall be measured as one length.Make:- Havells/ Polycab/ Plaza.  168 S&F in replacement factory madepowder coated distribution board SPN 6 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBconforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian  169 S&F in repairs 36 W (WW/WH) LED recessed2x2 luminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens.Make : Philips/ Bajaj/CG/Havells.  170 S&F as in repair PVC casing capping medium grade of size 25 mm on wall /roofwith help of screw including serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping,completeall as specified and as directed. Make: Polycab/ Modi/ Presto Plast  171 S&F in replacement factory madepowder coated distribution board SPN 4 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar including taking down unserviceable DBconforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian  172 S & F in repairs Modular blank plate one modulecomplete all as specified and directed.  173 S & F in repairs Modular Switch 1 way 6 A, 1 Module complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian  174 S & F in repairs Modular Switch 1 way 16 A, 1 Module complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian  175 S & F in repairs Modular socket 6 A, - 2/3 pin combined 2 module complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian  176 S & F in repairs Modular socket 6/16 A, - 3/5 pin combined 2 module complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian  177 S & F in repairs modular White cover plate with frame, 1 module  178 S & F in repairs modular White cover plate with frame, 2 module  179 S & F in repairs modular White cover plate with frame, 3 module  180 S & F in repairs modular White cover plate with frame, 4 module  181 S & F in repairs modular White cover plate with frame, 6 module  182 S & F in repairs modular White cover plate with frame, 8 module  183 S & F in repairs modular White cover plate with frame, 12 module  184 Supply, installation, testing & commissioning of maintenance free chemicalearthing system comprising of 17mm dia copper bondedrod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducingliquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed..Make : Model HTSP 317 of safeTrode or equivalent in Snaga/ Cubes 6 Global  185 The quoted rate shall also deemed to be included the following :- (i)Prior toinstallation of maintenance free chemicalearthing, soil resistivity test to be carried out at the location where earthingwork to be donein presence of Engr-in- Charge/JE (E/M),user and the report has tosubmitto Garrison Engineer with recommendation of manufacturer, if required additional interconnection ofearthing (not more than 08 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testingandsubmission of report with recommendationdeemed to be included in the quoted rate.  186 (ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.  187 (iii) Rateofearth energizer compound of 25 Kg of 02 bags and earthresistance reducingliquid 10 litre per cane for each pit deemed to be included in the quoted rate.  188 (iv)Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor along with the sample approval  189 (v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.  190 (vi) Copper strip of size 20 x 3 mm shallbe fixed on proper post insulator at the instrument end (copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately).  191 (vii)Testing of earth shall be carriedout in presence ofdepartmental and user representativeand report shall be submitted to Garrison Engineer duly signed by all concerned.  192 (viii)Earth resistance tester will be provided by the contractor.Tester should be calibrated from authorised company/ lab.  193 (ix)Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned.After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.  194 (x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.  195 (xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.  196 (xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained.  197 (xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period.  198 (xiv) The electrode shallcarry manufacturers name .  199 (xv) The connection clamp shall be permanentlly welded to the copper boundedrodto avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.  200 (xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.  201 (xvii)Earth work such as auguring andmaking good the surrounding area shall carried out in any type of soil.  202 (xviii)The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material.  203 (xix) Sign boardof mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxideZinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge.  204 M&L in repair Earth pit cover madeof heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mmfor each electrode pit, including taking down old u/s earth pit cover, complete all as specified and directed.  205 S&F in repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing old unserviceable copper strip of any description, complete all as specified anddirected. Note : - All Joints should be joined by Exothermic Welding or Brazing.  206 Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS complaints & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure shall be above 200mm for air circulation & to minimize temp rise. Panel shall be fitted with one No.polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 400 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20 mm graded stone aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board of any size and description, reconnecting existing LT UG Cable with new panel board, complete all as specified and as directed :-  207 (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 250 Amp, 36 KA- 01 No. (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity200 Amp,25 KA- 01No.(c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity125 Amp,25 KA- 02 Nos.(d) Multifunction Meter (V,I,PF) with suitable capacity of CTs- 01 No(e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(f) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).