}

Tender For Special Repair To Bldg No. Bk-120, Bk-142, Bk-132, And Bk-133 (Or Md Accn) At Sfts Bakloh, bakloh-Himachal Pradesh

Tender Notice

52136088
Tender For Special Repair To Bldg No. Bk-120, Bk-142, Bk-132, And Bk-133 (Or Md Accn) At Sfts Bakloh
Tender
Indian
Himachal Pradesh
Bakloh
01-12-2025

Tender Details

Special Repair To Bldg No. Bk-120, Bk-142, Bk-132, And Bk-133 (Or Md Accn) At Sfts Bakloh; 1 Demolition of cement concrete (un-reinforced) in ground floor and pavingn.exc 15 cm thick above or below ground level complete and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed. 2 Demolition of cementconcrete (reinforced) of any description and in any position not otherwise specifically provided for complete and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed. 3 Demolition of brick workor stonework built in cement mortar including allquoins, arches pillars etc but excluding ashlar facings ,dressed stonework and precast concrete articles and stacking the serviceable materials within 100m and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed. 4 Taking down cement plaster including backing etc from brick/stone walls / concrete surfaces including raking out joints,hacking for key , scrubbing down with water etc complete all as specified and directed 5 Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubish off the premises. complete all as specified and as directed. 6 Dismantling plain or corrugatedsteel sheetsany gaugethickness including Nanital or similar pattern roof covering including ridges complete all as specified and directed. 7 Taking downand removing chowkats with shutters (withouttaking off shutters from chowkat)not exceeding 1.50 Sqmeach complete all as specified and directed. 8 Taking down and removing chowkats with shutters (withouttaking off shutters from chowkat)exc 1.50 Sqmbut not exc 4.00 Sqm each complete all as specified and directed. 9 Dismantling wrought iron or mild steel work of any description not otherwise provided forcomplete all as specified and directed. 10 Demolition of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed. 11 Demolition of Stone slabsand tiles ( laid , bedded and pointed in any mortar) of any description or thickness in floors, aprons etc., complete all as specified. 12 Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in soft/loosesoil, complete all as specified and directed. 13 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm, complete all as specified and directed. 14 Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed. 15 PCC 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified. 16 PCC 1:2:4( nominal mix) type B-2 (using 40mm graded crushed stone aggregates) as in surface channel and drain all as specified and directed. 17 RCCType B-1, 1:2:4 (20mm graded crushed stone aggregate)as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. 18 Use & waste of form work to suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for fair finished surfaces of flat concrete, complete all as specified & directed. 19 Use & waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter forrough finished surface of flatconcrete complete all as specified and directed. 20 Use & waste of form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work not exc 10cmwide for rough finished surfaces of concrete, complete all as specified & directed. 21 Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth, complete all as specified. 22 Brickwork with old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in built incement mortar 1:6 all as specified & directed. 23 Walling of random rubble stone masonry,uncoarsed, well bonded, bedded and soilidly hearted,built in CM 1:6, complete all as specified and directed. 24 Pre-cast cement concrete , type C-1, 1:3:6 , using 20mm graded crushed stone aggregate block masonry with solid blocks, exc. 10 cm in width and setting in mortar 1:6,complete all as specified. 25 2nd class hardwood (Sal) plain solid straight chowkats and frames wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed. 26 35mm thickFlush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. 27 Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing as shown on page No176 to 183 of MES SSR 2020 Part-II compete all as specified and directed.(Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life) 28 Powder coated (minimum thickness of powder coating 50 micron), Anodised aluminium framefor doors, windows, ventilators with one or more rebates including joining cleat for fixing of glass, particle board,aluminium frame etc complete all as specified and directed. 29 Factory Made Solid PVC Moulded Door Shutter (Woood free EPS) , 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing, complete as shown on page No176 to 183 of MES SSR 2020 Part-II compete all as specified and directed. 30 35 mm thick2nd class hard wood (Sal/Hollock) glazed & skeleton factory made shutters, open rebated and prepared to receive glass, gauze etc (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass, etc, sizes of members ofdoor shutters as specified in SSR- 2009Part-I Section 8.24(a) complete all as specified and directed. 31 Powder coated (minimum thickness of powder coating 50 micron) aluminium window andventilators shutter side hung type without sash bars,without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mmlong (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1no.) complete all as specified 32 Aluminium handles, cast type, anodised of size 150 mm complete all as specified and directed. 33 Aluminium anodizedbarrel tower bolt of extruded section of size 200 mm and fixed complete all as specified and directed. 34 Mild steel butt hinges of size 100mm medium weight cold rolledcomplete all as specified and directed. 35 250mm longaluminium alloy, anodized, sliding door bolt with hasp, staple(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed. 36 300mm, Mild Steel, ordinary rat tail rod pattern springs including roller and roller plate completeall as specified and directed. 37 20mm dia Curtain rod/Harrison rails, anodised aluminium alloy, chromium plated with fixing brackets, stops, rollers etc, complete all as specified. 38 Sheet glass, 4.8mm thick ordinary quality and glazing with oil putty in squares n.exc 0.5 sqm each pane complete all as specified and directed. 39 100mm size, Hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed. 40 18/19mm thick Block boards, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work, complete all as specified. 41 Aluminium anodised snap grid frame (Powder Coated) work of size of size 605 mm X 605 mm as in false ceiling, flat or sloping (pattern as per manufacturers catalogue/ instructions), cuttingholes for electrical fittings fixed on and including aluminium tee of size 24mmX38mmX1.50 mm as main runner, aluminium tee of size 24mmX28mmX1.50 mm as cross runner and aluminium angle of size 24mmX24mmX1.50mm at the perimeter suspended from soffit at approx 900 mm centre to centre with hangers 6 mm dia galvanised (length as per site requirement) adjusting level fixed to roof by means of ceiling cleats made out of galvanised iron flat 40 mm X 3 mm size, 60 mm long and expansion hold fasteners 12.5 mm dia, 40 mm long including perforated particle board/tile 12mm thick for insulation and acoustic purpose as in ceiling flat or sloping 60cmx60cm in sizeincluding necessary scaffoldingall as specified and directed. 42 Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified, all as specified and directed. 43 Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. 44 Rolled mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to grade Fe 410 -W (Gde-E- 250) quality-B, complete all as specified and as directed. 45 Rolled Mild Steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe-410-W (Gde- E-250) quality-A complete all as specified and directed. 46 Mild steel TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed. 47 Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. 48 Plain cement concrete 1:3:6, nominal mix, type C-1, using 20mm graded mechanically crushed stone aggregate, 75mmthick as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen and two parts of heated coarse sand (by volume), all as specified. Note:- The unit rate include for use of form work (straight or curved). 49 75mm thick PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregates) as in sub base complete all as specified and directed. . 50 40 mm thick PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregates)as in levelling course,surface finished even andrough to receive topfinish complete all as specified and directed. 51 Mat finish, premium quality, joint free (edge cut), coloured/ printed Non-skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floors etc. set and jointed in neat cement slurry and including 15mm thick bedding layer in cement mortar (1:6) including necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed. Size/Shade/Colour of tile shall be approved by the AGE(I). 52 20mm thick, Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. 53 Cutting, rubbing/grinding& mirror finish ,rounding of edges of marble/ kota stone/ granite stonecomplete all as specified and directed. 54 Glazed ceramic colouredtilesof size350x 250x 7 mm/ 450X 350X 7mm mm thick as in vertical surfaces , set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tile over and including 10 mm thick cement screed in cement mortar 1:3 complete all as specified and directed. Size/Shade/Colour of tile shall be approved by the AGE(I). 55 Chequered cement concrete colouredtiles, homogenious texture glossy finished, chemically coated machine pressed 30 cm x 30cm x 25mm thick set, jointed and pointed in near cement slurry in floor with gray cement and pigment and including 20 mm thick cement screed in cement mortar 1:4 complete all as specified and directed. Shade/Colour of tile shall be approved by the AGE(I). 56 Rendering cement plaster 15mm thick in cement mortar 1:4 on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified. 57 Rendering cement plaster 15mm thick in cement mortar 1:6 on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified. 58 Rendering cement plaster 5mm thick in cement mortar 1:3 on fair faces of brick or on concrete surfaces, as in ceiling , surface finished even and smooth without using extra cement, all as specified. 59 Raised pointing to random or polygonal rubble, uncoursed or brought upto courses in cement mortar 1:4, complete all as specified. 60 Supply only intergal water proofing compound, complte all as specified. 61 Preparation of new wooden surfaces of any description, not otherwise described, over 10cm in width or girthand applying two coats of synthetic enamel paintover a coat of pinkprimer complete all as specified and directed. 62 Preparation of new steel surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paintover a coat of red oxideprimer complete all as specified and directed. 63 Preparation of old steel surfaces of any description, not otherwise described, over 10cm in width or girthand applying one coat of synthetic enamel paintcomplete all as specified and directed. 64 Preparation of old wooden surfaces of any description, not otherwise described, over 10cm in width or girthand applying one coat of synthetic enamel paintcomplete all as specified and directed. 65 Preperation of old plastered surfaces including complete removal of existing treatment and applying applying two coats of 100% acrylic smooth emulsion exterior grade with silicon additives and anti-algal properties Exterior over one coat of water proof primer on walls and chajjas with 10% dilution of water including smoothingthe surface with wall putty @ 2kg/ Sqm of average thickness 2mmwith silicon additives and sanding these surface for removal of loose particles , complete all as specified. 66 Preparation of old decorated plastered or unplastered surfaces including cleaning by brooming downor with steel wire brushing scraping down smoke soot, moulded moss and efflorescent salts and treating oil and greasy spotsand applying one coat of distemper oil emulsion on wallscomplete all as specified and directed.Note : Work shall be executed by mechnical means 67 Preparation of old decorated plastered or unplastered surfaces including cleaning by brooming downor with steel wire brushing scraping down smoke soot, moulded moss and efflorescent salts and treating oil and greasy spotsand applying one coat of white wash on ceiling complete all as specified and directed. 68 Preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over one coat of primer over complete, all as specified and as directed by Engr-in-ChargeNote : Work shall be executed by mechnical means 69 Preparation ofnewplastered surfaces or un plastered, previously undecorated ceiling surfaces and applyingthree coats of white wash, complete all as specified and directed. 70 Preperation of new plastered surfaces of walls and applying applying two coats of 100% acrylic smooth emulsion exterior grade with silicon additives and anti-algal properties Exterior over one coat of water proof primer on walls and chajjas with 10% dilution of water including smoothingthe surface with wall putty @ 2kg/ Sqm of average thickness 2mmwith silicon additives and sanding these surface for removal of loose particles , complete all as specified. 71 Wash basins, Vitreous China (Flat white type) size 550mmx400mm, with pedestal , crystal white with and including cutting for and pinning on ends of brackets, 450 mm long PVC connections 15mm size with PTMT coupling nuts at both ends, trap, grating and Union for discharge pipe, waste, chain and plug and porcelain stopper, waste pipe of polythylene of low or high density or PVC of 32mm dia ,and bedded in red lead cement and other end fixed, screwed for iron pipe and fixed, completeall as specified. Make: Cat Part No. 1008 of Cera or equivalent in makes mentioned in Appx 72 Bib tap, cast copper alloy ,chromium plated, fancy type , screwed for iron pipe or for brass ferrule of 15 mm bore, fixed in repair, complete all as specified and directed. 73 Stop valve/Angle Valve cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unionsfor 15mm bore iron pipe or for unions and fixed in repairs complete, all as specified. 74 Stop valve cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unionsfor 20mm bore iron pipe or for unions and fixed in repairs complete, all as specified. 75 Brass Chromium Plated, wall mixer for mixing hot & cold water screwed down for iron pipe and fixed 15 mm bore, fixed in repair, (Suitable for sink/bathroom) complete all as specified and directed. 76 Brass Chromium Plated, wall mixer for mixing hot & cold water screwed down for iron pipe and fixed 15 mm bore, fixed in repair, (Suitable for WHB) complete all as specified and directed. 77 PVC connections 15 mm size with PTMT nutsof length 450mm fixed in repair complete all as specified and directed. 78 Brass chromium plated tubular towel rail 20 mm dia, D type, 60 cms long between flanges fixed in repairs with and including chromium plated brass brackets, brass screws complete all as specified 79 Brass chromium plated shower rose 125mm sizewith or without swivel joints, including fixing to steel pipe or union.fixed in repair complete all as specified. 80 600x450 mm bevelled edge mirror of slected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plug with chromium plated brass screwed and cup washers. 81 PVC valve less, crystal white, syphonic action type flushing cistern 10 litre capacity, superior quality, plunger type, low level, with inlet, ball valve, float and handle, 32 mm dia PVC long bend flush pipe 90cm long and 15 mm dia 600 mm long PVC connection with CP brass coupling nuts and PVC washers at both ends fixed, fixed in repair, all as specified. Make: Cat Part No. 2602 ofCera or equivalent in makes mentioned in Appx . 82 Vitreous Chinaware squatting pan, ‘Orrisa pattern’ size 580 mm x 440 mm, crystal white, with cast iron ‘P’ or ‘S’ trap, front or back inlet, integral foot rest with provision of plain cement concrete M-15, type B-I using 20 mm graded crushed stone aggregate complete all as specified, incl making connections to trap and to flush pipe, etc and making good to floors to match existing, in repairs, all as specified. Make: Cat Part No. 2071 of Cera or equivalent makes mentioned in Appx C. 83 Sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm, complete all as specified. 84 G I tubingmedium gradeof 15 mm borewith all fittings and fixtures fixed to wall and ceiling or laid infloor/trenches, including taking down old GI tubing complete all as specified and directed. 85 G I tubingmedium gradeof 20 mm borewith all fittings and fixtures fixed to wall and ceiling or laid infloor/trenches, including taking down old GI tubing complete all as specified and directed. 86 110mm dia PVC(SWR)pipe single socketed with rubber ringjoints, laid/fixed to trenches or in floor or walls, fixed in repaircomplete all as specified and directed. 87 75mm dia PVC(SWR)pipe single socketed with rubber ringjoints, laid/fixed to trenches or in floor or walls, fixed in repaircomplete all as specified and directed. 88 PVC (SWR) 110mm bore (dia), Bends any type, with disminishing pieces or tapers and Jointing with Solvent Cement, complete all as specified and as directed. 89 PVC (SWR) 75mm bore (dia), Bends any type, with disminishing pieces or tapers and Jointing with Solvent Cement, complete all as specified and as directed. 90 75 mm dia PVC(SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. 91 Rotational moulded polyethylene water storage tank 500 Ltrs capacity four layered (ISI Marked) cylinderical vertical with closed top, hoisted and fixed in position with ball brass valve, high pressure with PVC float valve 20mm dia with polythene float and fly nut, tank nipples with check nuts and washers complete and making connections with existing water supply line, including dismantling old tank any type,complete all as specified. 92 Taking down point wiring with aluminium/ copper conductor for light point, socket point/ power point etc. in PVC casing and caping, surface pvc/ steel conduits, wood batten with clips including taking down board any type and size complete with any type of switches, sockets, holders, (batten or pendent type), ceiling rose etc. The light fittings (any type), main switches, distribution board with MCB’s of any capacity and make are to be removed/ replaced if required and all as specified and directed. NOTE: - Existing fan regulator any type (Where required) and electric meters are to be refixed and connected properly where required. 93 Point wiring for one light/fan/call bell point controlled by one 5/6 Amp switch with 1.5 Sqmm two single core multistranded copper conductor FRLSH, PVC insulated (unsheathed) heavy duty cable 1100 volts including continuous earth wire of size 1.5 Sqmm copper conductor multistrand FRLSH, PVC insulated (unsheathed) drawn into concealed rigid non-metallic PVC conduit Med Grade ISI marked not less than 20mm wide of 1.8mm wall thickness ISI marked including modular GI sunken flush box (Pressed steel powder coated Modular GI sunken flush boxes and cover plates of any way i.e. 1 to 8 way as per site requirement suitable for modular switch/socket) for mounting switches, sockets, fan regulators etc & making good to disturbed surfaces as well as matching with existing whitewash colour/surface complete all as specified and as directed for the following:- (a)Wiring shall be done by using proper colour coding(b)Earth wire shall be of green colour(c)On RCC roof/ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed. 94 All as per serial item No 93 above, but for one 3 pin 5 Ampssocket outlet on the same board all as specified and directed. 95 All as per serial item No 93 above, but for one 3 pin 5 Ampssocket outlet, independent all as specified and directed. 96 All as per serial item No 93 above, but for one light point controlled by two way switch all as specified and directed. 97 All as per serial item No. 93 above but for 3 pin 15 Amps socket out letindependentwith 2.5 Sqmm PVC copper conductor cable and and PVC insulated, unsheathed 2.5 Sqmm stranded copper conductor cable as continuous earth wire, all as specified. 98 Modular switch 1 way 6A, 1 module, all as specified. 99 Modular switch 1 way 16A, 1 module, all as specified. 100 Modular switch 2 way 6A, 1 module, all as specified. 101 Modular Bell push 6A 1 module, all as specified. 102 Modular Socket 6A/16A - 2/3 pin combined 2 module, all as specified. 103 Modular Socket, 6A - 2/3 pin combined 2 module, all as specified and directed. 104 Bell, AC, 230 volts, single pole all as specified. 105 Ceiling rose, 65 mm to 50 mm, two to three terminals, PVC/ Polycarbonate, insulated body fixed on PVC block, all as specified. 106 Modular fan regulator, step type, 2 module, all as specified. 107 LED type tube light, 1x20 watt 230 volts wall mounted Inverter LED batten with square profile and polycarbonate channel. Lithium Ion battery with charging time 8hours-10 hours and back up time upto 4 hours,internely pre wired and including connecting up with three core twisted flexible copper conductor cable of suitable size. Make: Havells cat part No. LHEXACP7FN1W020 or equivalent in Appx 108 Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack , 10 watt LED,6500k, two feet long, with all acessoreis internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable sizeincluding dismantling of unserviceable tube light all as specified and directed.Make: Havells Cat Part No. LHEXACP7IN1W010 ofHavells or equivalent in makes mentioned in Appendix 109 35Watt New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08. connecting with PVC insulated three core flexible copper conductor of suitable sizeto fitting including bracketmade up of 32mm dia GI pipe light grade 1.5 metre long and bent to shape required, complete all as specifiedMake: Havells cat part No. ENDURASUNDOWNSL35WLED765PASYBOPC or equivalent in Appx 110 Replacement of Sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 8 way, double door, 240 volts with 200 Amp rated bus bar completed all as specified. 111 Replacement of Sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 4 way, double door, 240 volts with 200 Amp rated bus bar completed all as specified. 112 MCB SPN32 Amp, 240 Volts, B Curve , 10 KA all as specified. 113 MCB SP 6 to 32 Amp, 240 Volts, B Curve , 10 KA all as specified. 114 Sub main wiring with two single core PVC insulated cable1100 volts grade with copper strandedRLS conductor of size 6 Sqmm (2 single run) with one continuous FRLS copper earthing lead wire ofsize 6 Sqmm and drawn into PVC conduit/ casing & capping with all fittings/ accessories, junction boxes1 to 4 way 20mm dia, cutting chases, making good in cement mortar (1:3), finishing surfaces to match with existing and connected to common earth dolly including taking down old unservicable submain wiring, complete and as directed. Note :- Two run (each run of 1 RM) of 6 sqmm copper conductor andone RM of earth wire of 6 Sqmm,shall be measured as one RM). 115 Meter box consisting space to fix MCCB as incomer and 04 Nos meter and providing 05 Nos MCB SPN 40 Amps 100mA, METER box double door fixed type wall mounted CRCA approved FACTORY MADE, 2 mm thick sheet enclosure outdoor type. The rates including taking down old DB and connecting in new panel with required wires with out any extra cost complete all as specified and directed. The panel should consists of the following :-INCOMING :-(1) MCCB 63 AMP 4 P 16 kA thermal magnetic based with o/c, s/c protection & ROH-01 No (2) Indicatinglamps RYB -03 NosOUTGOING :-(1) 40 Amp MCB SPN 100mA with enclosure -04 Nos (2) Space for refixing existing electrical meter -04 Nos. The internal wiring of panel should be of 6 sqmm from busbar to electric meter and electric meter to RCBO including a suitable size of thimbles NOTE:- (i) Contractor should visit the site and to prepare panel as per size required to fit below staircase of the bldg complete all as specified and directed by Engr-in-Charge.(ii) The rate also includes for taking down existing meter and refixing the same in Meter Panel 116 Supply and installing of Electric Water storage heater of ABS body type25 Litre Capacity with rated power 2 KW, 5 star rated, vertical type, thermally insulated Mild steel tank with, glass line coating inside he tank alongwith glass line incoloy heating element with anti corrosive magnesium anode, NRV, theremostate, indicators and temperature adjustable knob including steel braided flxible connection for pipe of size 15mm dia bore GI hexagonal adopeters./ Nuts on both sides of inlet (Cold water supply) & outlet (hot water supply) and including provision of wall mouting arrangement and mounting on wall with suitable size of anchor bolts with complete connection of water including testing after installation complete all as specified and as dierected by Engr-in-Charge. Note : (i)Old geyser shall be deposited in MES store yard. 117 Ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor(BLDC) , complete all as specified. 118 Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm, includin gtaking down old fan, complete allas specified.Note : Old exhaust fan shall be deposited in MES store yard. 119 Mild steel galvanised iron tubing light grade for fixed on both end of wall for fixing of fan hook including cutting on wall and making good the surface , complete all as specified and directed. 120 Aluminum strip 25x3.15mm fixed with porcelain/PVC saddlesand fixing screws etc including PVC gutties in each one metre length , for roof conductors and down conductors above ground, fixed in reapir , complete all as specified. 121 Air termination single pointed aluminum rod 12mm dia and 300mm long, complete all as specified. 122 Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexognal .head screw all as specified. 123 Sheet metal enclosurewith socket plug top and MCBs having single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20Amp 240V complete all as specified and as directed. 124 XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 6 Sqmm, 2 core, laid in trenches or passing through pipes, including making necessary connections at both ends, complete all as specified and directed. 125 Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC M-15, type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC M-15, type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixingarrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electricalplate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. 126 Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron strip 25X4 mm size (as earth lead strip), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 40 mm bore including provn of concrete pit in plain cement concrete M-15 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete M-15 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixingarrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electricalplate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. 127 Deduct Credit Amount as per Schedule of credit as details given on Srl Page No 30 of tender doucments.

Key Value

Document Fees
INR 1000 /-
EMD
INR 156940.0 /-
Tender Value
INR 87.96 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail