Tender For Provision Of Station Sainik Institute At Bikaner;  1 Lump sum price worked out by the tenderer for“BUILDING WORK as listed in Schedule ‘A’ Part - I  2 Subtotal  3 Lump sum price worked out by the tenderer for“INTERNAL ELECTRIFICATION WORK as listed in Schedule ‘A’ Part - II  4 Subtotal  5 Lump sum price worked out by the tenderer for“INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part - III  6 Subtotal  7 Lump sum price worked out by the tenderer for“ROAD , PATH & CULVERTS WORKS as listed in Schedule ‘A’ Part - IV  8 Subtotal  9 Lump sum price worked out by the tenderer for“AREA DRAINAGE WORKS as listed in Schedule ‘A’ Part -V  10 Subtotal  11 Lump sum price worked out by the tenderer for“SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’ Part VI  12 Subtotal  13 Lump sum price worked out by the tenderer for“COMPOUND WALL, FENCING & GATE as listed in Schedule ‘A’ Part -VII  14 Subtotal  15 Lump sum price worked out by the tenderer for“EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part -VIII  16 Subtotal  17 Lump sum price worked out by the tenderer for“SUMMAR APPLIANCE as listed in Schedule ‘A’ Part -IX  18 Subtotal  19 Lump sum price worked out by the tenderer for“SITE CLEARANCE AND EARTHWORK as listed in Schedule ‘A’ Part -X  20 Subtotal  21 Lump sum price worked out by the tenderer for“ARBOURICULTURE WORK as listed in Schedule ‘A’ Part -XI  22 Subtotal  23 Lump sum price worked out by the tenderer for“RAIN WATER HARVESTING as listed in Schedule ‘A’ Part -XII  24 Subtotal  25 Lump sum price worked out by the tenderer for“REFRIGERATOR AND DEEP FREEZER as listed in Schedule ‘A’ Part -XIII  26 Subtotal  27 Lump sum price worked out by the tenderer for“HOT WATER SUPPLY (SPL WORK) as listed in Schedule ‘A’ Part -XIV  28 Lump sum price worked out by the tenderer for“EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A Part -XV  29 Subtotal  30 Schedule ‘A’ Part- XVI (Misc)  31 Supply and fixing Pop-Up Impact sprinkler of heavy duty Plastic, adjustable to full-circle or Part circle with diffuser screw for fine drop lets and throw control, inlet size 3/4, having dia of throw up to12 mtrs at pressure 2-4 kg/cm² having discharge 456-1192 Ltr/Hrs complete all as specified and directed by engineer -In-Charge. Make Aquaturf.  32 Supply and fixing Swing joint full three way adjustability including height for Pop-Up Impact Sprinkler, bush with connected accessories, durable polyethylene construction for 3/4 size. Complete all as specified and directed by Engineer -In-Charge.Make Aquaturf/Elitech Drip  33 Supply and fixing PP Service saddle size 63mmx20mm with steel reinforced to be fixed over 63mm dia pipe for jointing of swing joint to PVC Pipe for Pop-up Sprinkler complete all as specified and directed.  34 Supply, install , testing and commissioning of horizontal open well submersible pump electric driven motor 3.0 HP/2.25 KW capacity, with supply voltage 415V, 3 Phase, 50Hz suitable for operation with operating head 10-28 Mtr and having capacity to discharge water 11.9-2 LPS with suction and discharge flanged suction 65 X 50mm with suction and delivery water line including flat Submercible copper conductor cable of size 4 Sqmm 3 Core from panel to motor as per manufacturer instructions including all connected accessories complete all as specified and directed by Engineer - In - Charge..(Make : CG /Kirloskar/MBH Pumps/KSB/Mather or eaquivalent).(For EP)  35 Supply anf fix Rotational moulded HDPE water (storage) tank of 5000 Ltrs capacity (Cylindrical vertical tank with closed top) hoisted on roof/ loweredunderground and fixed in position including making necessary arrangements for fixing inlet, outlet overflow pipe and provision of washout pipe with and including circular platform of height 30Cmbelow the tank and base 25Cm more than the external dia of tank casted into two layers of PCC wth first layer of 15Cm thickness of PCC 1:2:4 type B2 using with 40 mm graded aggregate and second top layer 15Cm thickness in PCC 1:3:6 type C1 using with 20 mm graded aggregate with smooth finish to exposed concrete surfaces including necessary form work etc complete all as specified and as directed by Engineer-In-Charge. Note :- (i) The water storage tank shall be tripple layer, HDPE tank moulded to seemless perfection of rotation moulding process.The tanks shall be manufactured only from FDA approved special grade poly ethelene and shall be certified fit for portable water including necessary foundation for placing the water tank.complete all as specified and directed. (Make :- Polycon/ Modi/Ganga/Sintex or eaquivalent).(ii) HDPE storage tank shall be as per IS- 12701.(iii) Necessary Earth work shall be meaasured and paid sepaerately.  36 Supply, install , testing and commissioning of horizontal open well submersible pump electric driven motor 7.5HP, 5.60 KW capacity, with supply voltage 415V, 3 Phase, 50Hz suitable for operation with operating head 20 - 30 Mtr and having capacity to discharge water 880-825 LPM with suction and discharge flanged suction 65 X 50mm with suction and delivery water line including flat Submercible copper conductor cable of size 6 Sqmm 3 Core from panel to motor as per manufacturer instructions including all connected accessories complete all as specified and directed by Engineer - In - Charge..(Make : CG /Kirloskar/MBH Pumps/KSB/Mather or eaquivalent  37 Angular jet fountain nozzel of gun metal with crome plated size inner dia 10 mm outer dia 12 mm Make: Raj, Aroma, creative or eaquivalent complete all as specified and directed.  38 Air jet fountain nozzel of gun metal with crome plated size inner dia 10 mm outer dia 12 mm Make: Raj, Aroma, creativeor equivalent complete all as specified and directed.  39 Supply and fix heavy dutyclass BGI Pipe and Fittings of Dia 50 mm Bore including valve, Cutting connection, fabrication with all connected accessories for making arrangement for supply of water from pump to nozzles (Inner and Outer ring of foundain) suitable for foundain of 1.5 mtr dia complete all as specified and directed.  40 LED base water proof programmable colour changing lights as per site requirement ABS, PVC Body, RGB Colour, operating voltage 18V DC colour programmable complete all as specified and directed.  41 Supply and fixing DMX controller for changing colour of light, micro processing controller with 18 V transformer as per site requirement having contrast show, medium fast or fading of colourmode.Make : Creative or equivalent. complete all as specified and directed. (One for Inner ring of fontain and one for Outer ring of Fountain)  42 Construction of valve chamber size 600x600x600 mm in PCC block of (1:4:8) built in CM (1:6) with MS cover 3mm thick double door type fixed to MS angle Iron frame using 50mm x 50mm x 6mm with locking arrangement including excavationand earth work in any type of soil, PCC (1:4:8) type D2 as in foundation, PCC (1:3:6) type CI using 20 mm graded stone aggregate as in bed, plastering 15 mm thick in CM (1:4) finished even & smooth without using extra cementand painting with one coat of red oxide primer and two coats synthetic enamel paint on all steel surfaces complete all as specified and directed by Engr-in-Charge. (For Foundain)  43 Supply, installing, commissioning and testing LT panel board (out door type) cubical type made out of CRCA sheet 3.15 mm thick dust and vermin proof and angle iron of suitable size , pedestal frame grouted in PCC (1:2:4) type B-1 20mm graded stone aggregated thimble and cable entry boxes with cable glands. Panel should covered from all sides with front and back lockable door and hinges complete with aluminum bush bar of capacity 50 Amps, TPN, three phase, 04 wire (In separate chamber) including painting with two coats synthetic enameled paint over a coat of red oxide primer and consisting of the following :-  44 (a)    Supply and fix 4 Pole MCCB 32 Amp, 50 Hz, 415 V with rupturing capacity, Thermal megnatic relay adjustable type 16/18 KA.– 01 Nos (Incomer)  45 (b)     Supply and fixMCB 3 Pole (TP), 20 Amp, 10kA, C Curve ratingsuitable for 415 Volts (Out going ). – 01 Nos  46 (c)     Supply and fixMCB 3 Pole (TP), 16 Amp, 10kA, C Curve ratingsuitable for 415 Volts (Out going ). – 01 Nos  47 (d)     Supply and fixMCB 2 Pole (DP), 16 Amp, 10kA, C Curve ratingsuitable for 240 Volts (Out going ). – 02 Nos  48 (e) DOL Starter for 7.5 HP/5.5KW with contractor (AC-3) and overlaod relay - 01 Nos  49 (f) DOL Starter for 3 HP/2.2KW with contractor (AC-3) and overlaod relay - 01 Nos  50 (g)Space for MCCB of- 01 Nos (Spare )  51 (h)Space for MCB SPN of- 04 No (Spare)  52 (k)     Digital Voltmeter with built in selector switch 0-500Volts -1No  53 (k)     Digital Ammeter with built in selector switch 0-50 amps with suitable CTs -1No  54 (l) LED Indicated Lamp (R,Y,B)  55 M&L for Earthing complete with galvanized iron slotted pipe of dia 40mm bore, 3 mtr long (earth pit not less than 10 mtr deep below normal ground level) surrounded by adequate quantity of charcoal, dust and salt to packed thickness of 15 cm on all sides, connected to GI Strip 32X6 mmby means of bolts, nuts check nuts and washers of galvanized iron and steel earth and rivetted/welded to earth plate at one end and other end of strip connected to equipemnent body/ test point with two nos nuts , bolts including 32X6 mm flat iron clamp. nuts bolts and washers and also watering pipe 20mm bore GI pipe medium garde from earth p[it to top electrode including funnel, wire mesh,copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregateand 40 mm thick PCC 1:2:4 type B1 cover complete all asshown in electrical plate No 3 of SSR Part-Iincluding necessary excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50 mtr complete all as specified and as directed. Note :-PCC Chamber shall be constructedatleast 1.5 Mtr away from the earthing electrode and pipe for watering shall be provided in stanting manner.  56 Supply ,installation ,testing and commissioningof Compact Sub – Station (CSS) comprising of 11 KV, 630 Amp VCB, 100 KVA Copper Wound Oil type Cooled Off-Circuit Transformer & one set of LT Panel as under : (a) HT section(i)11 kV, 630 Amp, Indoor Type, VCB Horizontal DrawoutHorizontal isolation floor mounting motorized panel with 230v motor mechanism & 24v DCShunt/Close coil with CT, PT, IDMT Relay, 8 Window Annunciator Model No. SI-801, BatteryPower Pack with 7AH Battery & in built charger for 24V Circuit and other fittings &accessories -01 Nos  57 (ii)Potential Transformer – 3 Phase cast resin of ratio 11kV/110V, Class-0.5, 100VA with HTPrimary -03 Nos  58 (iii)Current Transformer –Cast resin Ratio: 60-30/5+5A, Core1:Cl.0.5, 15VA, Core2:Cl.5P10,15VA -01 Nos  59 (iv)Protection Numerical 2OC + 1EF Relay and auxiliary relay -01 Nos  60 (v)Micro Processed based Non-Directional IDMT -1 Nos  61 (vi)Indication LampsVCB off / on / auto trip/ Trip circuit healthy/spring charge indication -01 Nos  62 (vii) Metering multifunction meter -01 Nos  63 (b) Transformer section :-100 KVA, 11/0.433 KV, 3 Phase, 50HZ, ONAN Cooled Oilimmersed Copper Wound Step Down “BIS Marked & BEE Star Labelled” TransformerComplete with first filling of IS:335 ISI Marked Filtered & Dehydrated Transformer Oil,having 7 position Off-Circuit tap changer with tapping range +7.5% in steps of 2.5% eachwith all standard fittings & accessories including OTI, WTI & Marshalling Box.Transformer as per IS-1180(Part-1)-2014 EEL- 3 with amendment no.- 4Losses @50% Load - 392WLosses @100% Load - 1365W  64 ©LT panel section :-LT Panel comprising of LV Side Incomer – 01 no. -250A 4P 415V 35 KA MCCB with thermal magnetic based release with O/L & S/C protection.RYB Indication ,Ammeter 250A/5A LTCT Cl:1.0 andVoltmeter  65 (d) Enclosure section:-(i)Space Heater with ON/OFF Switch and Thermostat, Single phase switch with socket, LTCubical illumination Lamp with Door Limit switch and MCB’s for AC / DC Control -01 set  66 (ii)MS Steel Sheet enclosure suitable for Outdoor Installation with MS base channel,Provision for receiving Incoming cables thro Bottom entry and out going ,through Bus bar to Trf panel, Excluding Termination Kit & Glands and Provision for receiving Incoming through bus duct by bus bar and Outgoing thro cable boxbottom entry Excluding Termination Kit & Glands -01 set  67 (iii) Busbar Aluminium and earth bus bar aluminium -01 set  68 (iv)Paint shade: Siemens Grey ( RAL 7032) -01 set  69 Supply and erect factory made 7 mtr long hot dip galvanized ( as per relevant IS with average coating thickness 65 micron) octagonal poles confiorm to IS-2062/BSEN 10025 with 130mm dia at bottom and 70 mm dia at top A/F made up of 3 mm thick HT sheet alongwith foundation type base plate of size 220X220X12 mm foundation bolt 04 Nos of M20X600 mm high J type EN8 grade, including 1 mtr long hot dip galvanized single arm (swan neck) bracket made up of 40mm dia GI pipecomplete all as specified and as directed.  70 M&L for Earthing complete with galvanized iron slotted pipe of dia 40mm bore, 3 mtr long (earth pit not less than 10 mtr deep below normal ground level) surrounded by adequate quantity of charcoal, dust and salt to packed thickness of 15 cm on all sides, connected to GI Strip 32X6 mmby means of bolts, nuts check nuts and washers of galvanized iron and steel earth and rivetted/welded to earth plate at one end and other end of strip connected to equipemnent body/ test point with two nos nuts , bolts including 32X6 mm flat iron clamp. nuts bolts and washers and also watering pipe 20mm bore GI pipe medium garde from earth p[it to top electrode including funnel, wire mesh,copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregateand 40 mm thick PCC 1:2:4 type B1 cover complete all asshown in electrical plate No 3 of SSR Part-Iincluding necessary excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50 mtr complete all as specified and as directed. Note :-PCC Chamber shall be constructedatleast 1.5 Mtr away from the earthing electrode and pipe for watering shall be provided in stanting manner.  71 Supply, installing, commissioning and testing LT panel board (out door type) cubical type made out of CRCA sheet 3.15 mm thick dust and vermin proof and angle iron of suitable size , pedestal frame grouted in PCC (1:2:4) type B-1 20mm graded stone aggregated thimble with minimum depth of 750 mm and cable entry boxes with cable glands. Panel should covered from all sides with front and back lockable door and hinges complete with aluminum bush bar of capacity 240 Amps, TPN, three phase, 04 wire (In separate chamber) including painting with two coats synthetic enameled paint over a coat of red oxide primer and consisting of the following :-(LT Panel No 4)  72 (a)    Supply and fix 4 Pole MCCB 160 Amp, 50 Hz, 415 V with rupturing capacity, Thermal megnatic relay adjustable type 25 KA.– 01 Nos (Incomer)  73 (b)    Supply and fix 4 Pole MCCB 125 Amp, 50 Hz, 415 V with rupturing capacity, Thermal megnatic relay adjustable type 16/18 KA.– 01 Nos( Outcoming)  74 (c)    Supply and fix 4 Pole MCCB 25 Amp, 50 Hz, 250 V with rupturing capacity,16/18 KA.– 01 Nos( Outcoming)  75 (d)     Supply and fixMCB 2 Pole (SPN), 25 Amp, 10kA, B Curve ratingsuitable for 240 Volts (Out going ). – 04 Nos  76 (e)Space for MCCB of- 01 Nos (Spare )  77 (f)Space for MCB SPN of- 02 No (Spare)  78 (g)     Digital Voltmeter with built in selector switch 0-500Volts -1No  79 (h)     Digital Ammeter with built in selector switch 0-200 amps with suitable CTs -1No  80 (j) LED Indicated Lamp (R,Y,B)  81 M&L Cable route / path indicators made out of 40x40x4mm angle iron 1.2 mtr long and plate of size 100x150x6mm welded only on one side end havinng embossed on plate as cable HT including PCC 1:4:8 of size 30cmx30cmx 30cm duly embedded the angle iron in PCC including excavation / earth work complete all as specified and directed.( each 40 RM)  82 Supply laying of double wall corrigated pipe of outer dia 63 mm and inner dia 50mm for cable protection complete all as specified and as directed  83 Supply laying of double wall corrigated pipe of outer dia 90 mm and inner dia 76mm for cable protection complete all as specified and as directed  84 Supply ,installation ,testing and commissioningof 11KV, 630 Amp,21KA ,Ring Main Unit, , ManualOperated,Non Extensible, Outdoor Type with one incomer and one outgoing with following specification :-STANDARD- IEC 62271-200RMU TYPE -11kV,630A,21KA/3SEC, VD NE MANUAL OUTDOOR SAFELINK RMURATED VOLTAGE-12 KVRATED BUSBAR CURRENT- 630 Amp RATED FREQUENCY- 50 Hz, POWER FREQUENCY WITHSTAND VOLTAGE / BIL -38 KV/98 KVp ,RATED SHORT CIRCUIT CURRENT-21KA ,RATED SHORT CIRCUIT CURRENT DURATION - 3sec ,DEGREE OF PROTECTION-TANK -IP67 ,DEGREE OF PROTECTION-SWITCHGEAR-IP54 ,BUS BAR MATERIAL -Copper ,AMBIENT TEMPERATURE(-)25 to 40degree C ,RMU FRONT COVER PAINT SHADE -RAl7035 ,RMU ENCLOSURE PAINT SHADE -DA GREY 632 OF IS5 ,ALTITUDE - <1000m ,BUSBAR INSULATING GAS -SF6 ,NOMINAL OPERATING GAS PRESSURE -1.2 Bar @20 deg C and Gas leakgae/annum -0.1% incl all foundation work all as specified and as direted .  85 Supplying and laying of CPVC pipes of dia 80mm SCH 40 in trenches including all fitting complete all as specified.  86 Supply and fixing Ductile ironsluice valve 80 mm dia with flanged ends class I PN 1.0(heavy duty ISI marked) confirming to IS:14846-2000, drilled type, gun metal spindle non raising type,with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed.  87 Cutting existing CI/DI pipe line of 150 mm and inserting tee of size 150x150mm for taping complete all as specified and directed.NOTE:- Necessary earth work, CI fitting/lead joints etc reqd to complete the job deemed to be included in the quoted rate.  88 Construction of Valve pit size 100cm X 100cm x 100cm of brick masonary from the top of surface including cover of MS Sheet 3.15 m thick and angle iron 40mm x40mm x 6 mm with hinges and locking arrangement including painting with two coat of synthetic ernamelled paint over a coat of red oxide and grouting to PCC 1:2:4 plastering in cement morter 1:3 foundation concrete 1:3:6 including necessary earthwork complete all as specified and directed .  89 Construction of Valve pit size 75cm X 75cm x 75cm of brick masonary from the top of surface including cover of MS Sheet 3.15 m thick and angle iron 40mm x40mm x 6 mm with hinges and locking arrangement including painting with two coat of synthetic ernamelled paint over a coat of red oxide and grouting to PCC 1:2:4 plastering in cement morter 1:3 foundation concrete 1:3:6 including necessary earthwork complete all as specified and directed .  90 Material and labour for cutting of Bituminus road/hard standing/ dismantling of interlocking paver blocks from pathways including excavation and earth work upto required depth and make the surface as old complete all as specified and as directed.Note :Rate for Bituminus road/PCC/interlocking tiles as required for making good disturbed surface are deemed to be included in the quoted rates. No extra payment will be made against above item.  91 Supply and Installationof Desert cooler electric driven single phase 230 voltsSteelbody having nominal air flow capacity of 4000 Cu M per hours with necessary inlet connection with HDPE/Flexible pipe both ends CP brass complete including electric connection complete all as specified and as directed.  92 Supply & installation of voltage stabilizer of capacity 1 KVA for automatic operation, single phase naturally air cooled indoor type & Design for input voltage variation between 170V to 250 V with output voltage stabilizer at 230 V with accuracy of +/- 2.5% complete as specified and as directed.  93 Supply, install, testing and commissioning of room air conditioner inverter type unit hot and cold typewith minimum 5 star rating and latest EER capacity 2TR (split type unit comprising of indoor and outdoor unit) electric driven (single phase 230 volt, 50 Hz) including necessary fixing arrangement for connecting copper tubing, wiring connection, insulated piping complete (indoor unit at suitable place and height inside the room and outdoor unit at suitable place outside the room) including metallic bracket with fixing nut bolts for outdoor unit etc. complete as specified and as directed.Note:- (a) Suitable piping shall be provided of adequate length of size 5/8 for draining of condensate water from indoor unit. Cost of same shall deemed to be included in quoted rate. (b) Suitable Copper tubing in addition if required extra as per site requirement from indoor unit to outdoor unit shall be provided and cost of same shall to be included in quoted rate. (c) Cost for Metallic bracket and nut bolt for fixing indoor and outdoor unit including necessarycutting / grouting in walls by cutter and making good the surface in CM 1:3 and to the original finishes (white wash/colour wash/Distemper) shall deemed to be included in quoted rate. (d) Gas for priming/charging in addition if reqd for Air conditioner unit shall be provided and cost of same shall to be included in quoted rate.  94 Supply installation commissioning of Voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of 2.5% and of capacity 5KVA.  95 Supply andfixing ,testing, commissioning frost free doubledoor refrigerator electric driven single phase 230 volts, AC 50 Hz of Capacity 310 Ltr with BEE 5 star rated complete all as specified and as directed.  96 Supply & fix Voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of 2.5% and of capacity 1KVA.  97 S&L for DWCPE (SN8) confirming to IS-16098,150mm nominal bore (160mm OD) complete laid in trenches on and including bed 100 mm thick bedding compressing of well compected clean poorly graded gravel,gravel/sand mixture with little or no fines to required slope,including all accessorries/fitting/jointed and testing complete all as specified and directed.  98 S&L for DWCPE (SN8) confirming to IS-16098,200mm nominal bore (238mm OD) complete laid in trenches on and including bed 100 mm thick bedding compressing of well compected clean poorly graded gravel,gravel/sand mixture with little or no fines to required slope,including all accessorries/fitting/jointed and testing complete all as specified and directed.  99 M&L for loose filling with broken stone or boulder aggregate of gauge 20 as in filter bed complete all as specied.  100 Material and labour for preparation of ground and plantation of grass with ‘Carpet’ grass (Selection-1)including watering and maintenance of the lawntill the grass forms a thick lawn free from weeds and fit for mowing including supplying good earth if needed including supplying and spreading of Neem oil cakes, manure or sludge and chemical required for preparation of the ground for plantation of grass. The preparation of ground include surface dressing, uprooting vegetation, shurbs etc, removing boulders, pebbles and leveling the surface flat or in slope complete all as specified and as directed by Engr-in-Charge.  101 Supply and planting of Hedge (of golden duranta) as directed by Engineer-in-Charge including creation of beds by excavating 60 cm deep and 60 cm wide trenching the excavated base to a further depth of 30 cm refilling the excavated earth after breaking clods and mixing with manure in the ratio 8:1 (8 part of stacked volume of earth after reduction of 20% with 1 part of stacked volume of manure after reduction by 8%) and flooding with water filling with earth if necessary, watering and finally fine dressing levelling etc inclding stacking and disposal of material decleared unserviceable and surplus earth by spreading and levelling as directed within a lead of 50 m and lift upto 1.5 m complete all as specified and as directed.  102 Supply and planting of following plants in 0.25m to 0.30 poly bags with height as mentioned belowincluding digging holes 1.2m dia x 1.20m deep in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio 2:1 (2 parts of stacked volume of earth after reduction of 20% with 1 part of stacked volume of sludge or manure after reduction by 8%) flooding with water and removal of surplus soil, with & including antitermite treatment using suitable chemicals as required and making Thaola complete all as specified.  103 Note :-  104 The contractors quoted rates shall be deemed to include for necessary excavation and earth work, necessary manure of sludge and antitermite treatment of soil including necessary chemicals etc.  105 The excavated earth if found suitable and approved by GE shall be used for filling in the holes after planting of trees/plants.However, in case the excavated earth is not found suitable for refilling and not approved by GE, contractor shall arrange suitable goods earth from his own sources as approved by GE and contractors quoted rates shall be deemed to include for arranging and transporting of food earth including filling in the holes and nothing extra shall be admissible on this account.  106 Bottle Palm ( Minimum height 4 to 5 feet above ground)  107 Bogounvillia ( Minimum height 3 to 4 feet above ground)  108 Tikoma ( Minimum height 3 to 4 feet above ground)  109 Kaner of white or yellow flower ( Minimum height 3 to 4 feet above ground)  110 Neem ( Minimum height 4 to 5 feet above ground)  111 Ashoka Plant ( Minimum height 4 to 5 feet above ground)  112 M&L for maintenance of all plants and Grass by weeding, hosing, saucer making once in every month for plants/hedge, once in every 15 days for Carpet Grass / Country Grass / Doob Grass, Burmuda Grass, pruning dried branches once in every week, depositing the material at places as directed by Engineer-in-charge and planting the new plants in place of dead plants of same species and height turing with doods wherever required by replacing the dead plants of grass of any type with same grass as required without any extra cost to the department including water pump operation on daily basis (minimum two hours daily) for watering the plants, Hedges, Shrubbery and Grass and cleaning the filters in irrigation system whenever required complete all as specified and as directed.  113 Supply and instalation of modular kitchen setup for below the granite top kitchen otta. Framing of partition in powder coated aluminium pipe of 25x50mmx1mm thickness for fixing shutters and drawers units. Teak wood pattern pipe frame fixed with L-shaped ss angles. All drawers units must be of Hitech make raft clossing system. All the facia for drawers units and shutters should be made of 18mm thick prelaminated WPC board with highglass laminate 1mm thick on outside and 0.8mm thick highglass laminate at innerside. Edge Should be fitted with 1.30mm thick high glass edge band on all shutters and drawers facia incl all fittings and water proofing sheet below granite all as specified and directed.  114 Supply and fixed Overhead cabinate should be of 600mm height made from 18mm thick prelaminated WPC board. Outside it should be fitted with 1.0mm thick high glass laminate and inside surface should be fixed with 0.8mm thick high glass laminate.All edges should be fixed with 0.8mm thick high glass edge band length of the cabinate should be divided with partition of plywood as per requirement. Overhead cabinate shutters should be ope on top with auto closing hinges and gas lift make Hitech Length of overhead cabinate can be extended to any length as per requirement. Note: V -channel handle must be provided to all over head cabinate shutter, openable shutter and drawer units below otta level as specified and directed  115 Chair Easy(FD-229)  116 Table Office clerk (FD-1004)  117 Stool Steel (FD-409)  118 Ladder Aluminium (FD-1025)  119 Durrie 15x12(TP)  120 Table900x900mm Steel (FD-1009)  121 Table 900x600mm with Drawer Steel (FD-1008)  122 Table 900x600mm without Drawer Steel (FD- 1007)  123 Teapoy (FD-278)  124 Receptacle PVC (FD/E6/MAP/13)  125 Chair Multi Seater Steel , Make Superq, Make: Godrej, Model: MATRIX (FUMTX3XS402SXTRD)/ Make: Durian, Model: TTRACK3/ Make Superq, Model: Three Seater Settee Indian (SS-304 Grade) (TP)  126 Table Serving 6x3(FD-411)  127 Chair Writing Cushion (FD/E6/MAP/12)  128 Restaurant Chair Make :Durian Model :Lister or equivalent model in Godrej/ Geeken (TP)  129 Chair Verandah (FD_256)  130 Teapoy Verandah MAP(FD/E6/MAP/17)  131 Supply & fixing Long body Bib tap Suitable for 15 mm bore pipe, cast copper alloy, fancy type chromium plated, screwed down high presure, with crutch of butterfly handle, screwed both ends for iron pipe or for brass ferrule & fixed, complete all as specified and as directed  132 S & F Urinal spreader of cast copper alloy, fancy type chromium plated, screwed down high presure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions and fixed suitable for 15 mm bore of pipe including necessary fittings & fixed complete all as specified and as directed and shown on drawing.  133 Supply & fixing PVC connection 15 mm size with cast copper alloy nuts of length 450 mm & fixed complete all as specified and as directed and shown on drawing  134 Supply & fixing Stainless steel Solid body fancy type peg set of six and fixed in position with steel with steel screws,complete all as specified and as directed and shown on drawing