Tender For Construction Of Fsb Over Lamang, District Shi-Yomi, Arunachal Pradesh.; 1 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. 2 Ordinary rock. 3 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each layer by ramming and watering, lead up to 50m and lift upto 1.5m 4 Supplying chemical emulsion in sealed containers including delivery as specified 5 (a) Chlorpyriphos Emulsifiable concentrate 20% @ 1.0 ltr per sqm of covered area 6 Stone soling under floors including watering, ramming consolidating and dressing complete: upto 5 km 7 CONCRETE WORK 8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering in footings and bases of columns (All work upto plinth level). 9 1:5:10 (1 Cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) 10 Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4graded stone aggregate 20 mm nominal size.) 11 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 12 R.C.C WORK 13 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement. 14 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 15 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 16 : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) All work from plinth level upto floor roof lvl 17 (a)Walls, columns, pillars, posts and struts 18 (b) Beams, plinth beams, girders, bressumers, cantilevers, suspended floors lintels roofs and staircases including spiral staircases, shelves etc. (refer beam column measurements) 19 FORMWORK 20 Centering and shuttering including strutting, propping etc. and removal of form for: 21 Foundations, footings, bases of columns, etc. for mass concrete. 22 Suspended floors, roofs, landings, balconies, shelves and access platform. 23 Lintels, beams, plinth beams, girders, bressummers and cantilevers. 24 Columns, Pillars, Piers, Abutments, Posts and Struts. 25 Ramps 26 Walls 27 STEEL REINFORCEMENT 28 Reinforcement of RCC work including straightening, cutting, bending, placing in position and binding all complete. Cold Twisted Bars 29 BRICK WORK 30 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V evel in all shapes and sizes in : 31 Cement mortar 1:4 (1 cement : 4 coarse sand) 32 FLOORING 33 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 34 40 mm thick with 20 mm nominal size stone 35 FINISHING 36 12 mm thk cement plaster 1: 4 (1 cement : 4 coarse sand) on walls. 37 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement :4 coarse sand) 38 6 mm thick cement plaster (1 cement : 3 fine sand) to ceiling. 39 Providing and applying white cement based putty of avg thickness 1.0 mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete 40 White washing with lime to give an even shade. 41 New work (three or more coats) 42 Finishing walls with water proofing cement paint of approved brand and manufacture and of required shade to give an even shade 43 Applying one coat of cement primer approved brand and manufacturer on wall surface : 44 WOOD WORK 45 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position : 46 Kiln seasoned and chemically treated hollow wood Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc. 47 Kiln seasoned and chemically treated hollock wood Wooden Partion of 75 mm thk provided internally 48 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part-I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 49 35 mm thick including ISI Marked Stainless 50 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) Transparent or dyed to required colour or shade, with necessary screws etc. complete: (a) 125 mm 51 Providing and fixing aluminum hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 52 Twin rubber stopper. 53 Providing and fixing aluminum hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. (a) 250x10 mm 54 Providing and fixing MS grills of required pattern in frames of windows etc. with MS Flats, square or round bars etc.including priming coat with approved steel primer all complete. 55 Fixed to steel windows by welding 56 STEEL WORK & ROOFING 57 Steel work in built up tubular trusses including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. Hot finished welded type tubes 58 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ 59 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self 60 drilling/ self tapping screws complete : 61 (a) Ridges plain (500 - 600mm) 62 (b)Gutter (600 mm over all girth) 63 Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Rockwool conforming to IS: 8183,density 48 kg/ m3, 50 mm thick, wrapped in 200 G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5mm false ceiling 64 Weight to be carried by head load from to work site. 65 Estimate - Internal Electrical Installations 66 POINT WIRING 67 Point wiring in PVC conduit, with modular type switch 68 Wiring for light point /fan point/exhaust fan point/call bell point with 1.5 Sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular switch, modular plate, suitable size GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc. as required 69 Group C 70 Circuit/sub-main wiring in PVC conduit:- 71 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor,single core cable in surface/recessed PVC 72 (a) 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire (for ckt wiring) 73 (b) 2 x 4 sq. mm + 1 x 4 sq. mm earth wire (for power plug) 74 (c) 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 75 (d) 2x10 sq.mm+ 1x10sq. Mm earth wire.(for Common Area DB) 76 (e) 4x10 sq.mm+ 2x10sq. Mm earth wire.(for DBs) 77 (f) 4x16 sq.mm+ 2x16sq. Mm earth wire.(for DBs) 78 Supplying & drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 79 (a) 3X4 Sq. mm 80 (b) 3X6 Sq.mm 81 TV Cable in existing Conduit 82 Supplying and drawing co-axial TV CableRG - 6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in thye existing surface/ recessed steel/ PVC conduit as required. 83 S/F PVC conduit : 84 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 85 S/F modular type switch/socket : 86 Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 87 (a)5/6 amps switch 88 (b)3 pin 5/6 amp socket outlet 89 (c)TV Antenna Socket Outlet 90 S/F modular type electronic fan regulator :- 91 Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 92 S/F modular boxes, base & cover plate :- 93 Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 94 (a) 1 or 2 Module (75 mm x 75 mm) 95 (b) 4 Module (125 mm x 75 mm) 96 S/F light plug point modular type accessories: 97 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc. as required. 98 S/F power plug point modular type accessories: 99 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 & 5/6 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required. 100 ITC ceiling fan : 101 Installation, testing and commissioning of ceiling fan including the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insualted, copper conductor, single core cable and earthing etc. as required. 102 ITC exhaust fan upto 450 mm sweep : 103 Installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, coonection, testing, commissioning etc. as required 104 Fixing louvers/shutters for exhaust fan 105 Extra for fixing louvers/shutters complete with frame for a exhaust fan of all sizes. 106 MCB DISTRIBUTION BOARDS 107 S/F prewired SP MCB DB :- 108 Supplying and fixing following way, single pole and neutral, prewired, sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with loose wire box, terminal blocks, duly prewired with suitble size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolator) 109 (2 +4) way Double door 110 S/F prewired TP MCB DB :- 111 Supplying and fixing following way prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/recess complete with loose wire box, terminal connectors for all incoming & outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc.as required.(But without MCB/RCCB/Isolator) 112 8 way (4+24), Double door 113 Vertical TPN DB 114 Supplying & fixing following ways surface/ recess mounted, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, with provision of 100 amps TP 16 KA MCCB as in comer, interconnection between incomer MCCB & busbars (but without MCBs/ MCCB) as required.( Note: Vertical type MCB TP DB is normally used where 3 Phase outlets are required.) 115 8 Way TP 116 Providing & fixing following rating & breaking capacity & pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connection, etc. as required. 117 100 Amp, 16 KA, TP MCCB 118 S/F C curve, SP MCB 119 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc.as required. 120 Single Pole 121 Supplying and fixing following rating ,double pole (single phase and neutral ),240 Volts, residual current circuit breaker (RCCB), having senstivity crrent up to 300 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 122 32 amps 123 S/F 20A SPN MCB Industrial Socket outlet 124 Supplying & Fixing 20 Amps, 240Volts, SPN Industrial Type Socket Outlet, with 2 Pole and earth, metal enclosed plug top alongwith 20 amps C curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing & commissioning as required. 125 Providing & fixing M.V danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red color on front side as required 126 EARTHING 127 Earthing with G.I earth pipe 4.5 mtr long , 40mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and water pipe etc.with charcoal and salt complete as required.( External Poles) 128 Earthing with G.I earth plate 600mm X 600 mm X 6 mm thick including accessories, & providing mansonary enclosure with cover plate having locking arrangement & watering pipe of 2.7 Metre long etc. with charcoal/ coke & salt as required( Equipments) 129 Earthing with copper earth plate 600mm X 600 mm X 3 mm thick including accessories, & providing mansonary enclosure with cover plate having locking arrangement & watering pipe of 2.7 Metre long etc. with charcoal/ coke & 130 Providing and fixing 25 mm x 5 mm G.I earth strip from earth electrode as required. 131 Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing as required 132 SUPPLY OF LIGHTING FIXTURES & FANS 133 Supplying the following Lighting fixtures including lamps at site. Rate shall include all taxes and duties, transportation etc. complete. Use all Philips Trulite/Osram lumilux plus Eco lamps in Fluorescent lamp fittings. ( 4000 K) Use Osram CFL lamp - Dulux L Lumilux in all CFL lamp fixtures (4000 K) (Samples of all light fixtures to be submitted to the client for approval prior to procurement of fixtures) 134 All Light Fixture shall be with H.F. electronic ballast ( THD less than 11% and P.F. 0.95 ) 135 (a)2 X 36 watts CFL recessed mounted light fixture as per Wipro Cat. No. WVP 74236 136 (b) 12 dia 1 phase exhaust fan, 1400 RPM 137 (c) 2x18 Watt CFL Light fixture as per Wipro Cat. No. WCP 36218 SGW or as equivalent 138 (d) 48 dia (1200 sweep) ceiling fan 139 SANITARY FIXTURES & ACCESSORIES 140 Providing and fixing white vitereous china pedestal type water closet (European type W.C. pan) with seat as lid,10 litre low level white P.V.C flushing cistern including flush pipe with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. 141 W.C pan with ISI marked white solid plastic seat and lid. 142 Providing and fixing wash basin with CI brackets,15mm brass pillar taps,32mm CP brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever required. 143 White Vitreous china Flat back Wash Basin size 550X400 mm with single 15mm C. P. brass pillar tap 144 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 145 (a)32 mm dia (for wash basin) 146 (b)40 mm dia (for sink and urinal) 147 Providing & Fixing 600 X 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 148 Providing & fixing viterous china toilet paper holder. 149 Providing & fixing stainless steel A ISI 304(18/8) kitchen sink as per I.S 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required: Kitchen sink with drain board. 150 510 x 1040 bowl depth 250 mm 151 WATER SUPPLY PIPES AND FITTINGS 152 Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This including jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. 153 Concealed work including cutting cheases and making good the walls etc. 154 (a) 15mm nominal outer dia pipes 155 (b) 20mm nominal outer dia pipes 156 (c) 25mm nominal outer dia pipes 157 Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings. This including jointing of pipes & fittings with one step CPVC solvent cement , trenching, refilling & testing of joints complete as per direction of Engineer in charge. 158 40mm Nominal outer dia pipes 159 Providing & fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 160 25 mm nominal bore 161 Providing & fixing unplasticised PVC connection pipe with brass unions. 15 mm nominal bore 45 cm long 162 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931. (15 mm nominal bore) 163 Providing and fixing C.P brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms (15 mm nominal bore). 164 Providing and fixing brass stop cock of approved quality: 15mm Nominal bore 165 Providing & fixing C.P brass shower rose with 15 mm inlet. (100 mm dia). 166 PART B (NON-SCHEDULED ITEMS - AS PER MARKET RATES) 167 Providing and fixing of C.P. Brass health faucet for ablution with 1 meter long PVC tube, hand shower, couplings, wall hook and other accessories. (Jaquar 573 or equivalent) 168 Providing and fixing of 32 mm dia. C.P.Brass bottle trap with 190 mm long wall connection pipe in place of P.V.C. waste pipe for wash basin discharge. (Jaquar 773 or equivalent) 169 Providing and fixing of 600 mm long C. P. brass towel rail complete with C.P. brass brackets. (Jaquar 1111 or equivalent) 170 Providing and fixing of 15 mm dia. inlet C.P. brass adjustable shower with 190 mm long shower arm complete with flange of approved quality. (Jaquar 477 + 493 or equivalent)