}

Construction Of Modern Workshop, Training Room Etc. At Govt. I.T.I. Fatehpur Chaurasi District-Unnao (U.P.) - Construction Of Modern Workshop, Training Room Etc. At Govt. I.T.I. Fatehpur Chaurasi District-Unnao (U.P.) 2 Civil Works 3 Earth Work In Exc, fatehpur-Uttar Pradesh

Tender Notice

52106439
Construction Of Modern Workshop, Training Room Etc. At Govt. I.T.I. Fatehpur Chaurasi District-Unnao (U.P.) - Construction Of Modern Workshop, Training Room Etc. At Govt. I.T.I. Fatehpur Chaurasi District-Unnao (U.P.) 2 Civil Works 3 Earth Work In Exc
Tender
Indian
Uttar Pradesh
Fatehpur
07-11-2025

Tender Details

Construction Of Modern Workshop, Training Room Etc. At Govt. I.T.I. Fatehpur Chaurasi District-Unnao (U.P.) - Construction of Modern workshop, Training room etc. at Govt. I.T.I. Fatehpur Chaurasi District-Unnao (U.P.) 2 CIVIL WORKS 3 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil 4 Supplying and filling in plinth with coarse sand under floors, including watering, ramming, consolidating and dressing complete. 5 Supply and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 6 Providing and injecting chemical emulsion for preconstruction ant termite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete(plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows :(3) Treatment of top surface of plinth filling 5 liters/sqm . 7 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 8 Providing and laying in position machine battched and machine mixed design mix M- 25 grade cement concrete for RCC work using cement content as per approved design mix. Including pumping of concrete to site of laying but including the cost of centreing, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impaaining strenght and durability as per direction of Engineer - In - Charge 9 All works upto plinth level 10 Footing 11 column 12 Grade beam 13 Slab on floor 14 All works above plinth level upto floor V level 15 Lintel 16 Slab/Chhajja 17 Column 18 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 19 Centering and shuttering including strutting, propping etc. and removal of form for 20 Foundations, footings, bases of columns, etc. for mass concrete 21 Columns, Pillars, Piers, Abutments, Posts and Struts 22 Lintels, beams, plinth beams, girders, bressumers and cantilevers 23 Suspended floors, roofs, landings, balconies and access platform 24 Lintels, beams, plinth beams, girders, bressumers and cantilevers 25 Suspended floors, roofs, landings, balconies and access platform 26 Columns, Pillars, Piers, Abutments, Posts and Struts 27 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 28 Providing and laying damp proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 Coarse sand : 4 graded stone aggregate 12.5mm nominal size) 29 Providing and applying a coat of residual petroleum bitumen of grade of VG - 10 of approved quality using 1.7 kg per sqm. On DPCafter cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 30 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 31 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation M-150 in Superstructure above plinth level up to floor V level. : Cement Mortar 1:4 (1 Cement : 4 Coarse sand) 32 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. 33 Providing & applying 3mm High build solvent free, self-levelling, epoxy flooring. Grinding and Scrubbing of allocated surface for the removal of dirt, oil, Grease & other contamination Surface. Blowing/Vacuumcleaning of surface, Repair the surface up to where ever required, Application of two part Epoxy Primer,Application of High build EpoxySelf levelling Screed Base coat followed by Application of hard wearing Epoxy Self levelling top Coat.Make: Asian Paints, Ucoat etc 34 Providing & Laying trimix vaccum dewatering the concrete floors using Tremix .including curing ,providing and mixing of hardening compound @ 2 kg/sqm ,cutting of VDF floor 100-150mm thick with diamond saw system as per specification including filling of colpor of fosroc make etc .complete as per specification and drawing . 35 Providing and laying Vitrified tiles in floor in different sizes(thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm includinggrouting the joints with white cement and matching pigments etc. The tiles must be cut withthe zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel,plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size Size of Tile 600 x 600 mm 36 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 37 Providing and fixing rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm. Including grouting the joints with white cement and matching pigments etc, complete. 38 12 mm cement plaster of mix : 1 : 6 (1 cement : 6 coarse sand) including cost of all labour, material T&P etc complete. 39 Engraving line in the plaster of the outer face wall vertically and horizontally to display the surface as s directed by the engineer -in-charges including labour and T&P etc. required for completion of work in the proportion recommended by themanufacture. 40 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections 41 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 42 Finishing walls with Acrylic Smooth exterior paint(APEX)of required shade : New work (Two or more coat applied @ 1.25 ltr/10 sqm over and including priming coat of exterior primer applied @.75 LTR/10 sqm) 43 Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work.Applying one coat of water thinnable cement primer of approved brand and manufacture on wallsurface : 44 Painting with synthetic enamel paint or approved band and manufacture of required colour to give an even shade. Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 45 Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. 46 After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profiledimension in higher side shall be accepted but no extra payment on this account shall be made. Ventilator Casement window single panel with or without fixed panel with S.S. 304 friction hinges as per size and weight of sash, single point locking zinc alloy (zamak) powder coatedhandles. 47 Using R2 series with frame (39mm & above ) x (39mm& above) & sash /mullion (39mm & above) x (60mm & above). (Height upto 1.2 metre) 48 Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads ofappropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. 49 Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Fixed window / ventilator without mullion / transom.Using R1 series with frame (33mm & above ) x (35mm& above). (Height upto 0.90 metre) 50 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener,including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. 40X40X5 51 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete..Fixed to steel windows by welding 52 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) nondecorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 53 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architecttural drawings and the directins of engineer-in-charge (Cost of aluminium snap beadingg shall be paid in basic item) With float glass panes of 5 mm thicness/weight not less than 12.50kg/sqm) 54 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestorywindows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. With 12 mm mild steel U beading 55 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). 56 Providing and fixing of stainless steel 304 grade handle for door.32mmx 600 mm long sss.(Ozone make) 57 Providing and fixing of Ozone make locks for toughened door including cost of all material labour etc complete . 58 Providing and fixing ISI marked S.S Sliding door bolts with nuts and screws etc. complete 300x16 mm 59 Providing and fixing ISI marked S.S.. Tower bolt black finish, (Barrel type) with necessary screws etc. complete 300x10 mm 60 Providing and fixing S.S. handles with screws etc. complete: 125 mm 61 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 62 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required andmaking good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-incharge. With stainless steel cover plate minimum 1.25 mm thickness 63 Supplying and fixing rolling shutters of approved make made of required size of M.S. laths interlocked together througgh their intire length and jointed together at the end by end locks mounted on specially designed pipe shall with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS:4454 part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25m M.S. Laths with 1.25mm thick top cover 64 Providing and fixing ball bearingg for rolling shutters 65 Extra for providingg mechanical device chain and crank operration for operating rollingg shutters. Exceeding 10.00 sqm and upto 16.80 sqm in area (say average 14 sqm) 66 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes 67 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be suppliedin single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 68 Thermal Insulation of roofing with Expanded polystyrene fixed with suitable adhesive to the false ceiling as per the directions of the Engineer-in-charge: With Type N - Normal 50 mm thick 69 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete (Ridges plain (500 - 600mm) 70 Providing & fixingGE plastic 600mm dia Turbo vents of approved make and laying in position as per drawing or as per directed by Engineer in charge 71 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Gutter (600 mm over all girth) 72 Providing and fixing of UPVC SWR pipe type -B confirming to IS -13592 including jointing the pipe with rubbing ring ,lubricant and UPVC SWR cupler confirming to IS -14735 ,ALSO Including excavation of trenches cutting of walls and holes and repairing the walls ,floors and refiling the trenches as before but excluding supply and cost of other fitting such as elbow bead ,tee and Y -tee including supply of all materials labour and t&p .Required for proper completion of the work . 150 mm dia 73 Providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595 mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7) in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm ) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32 mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised @80 gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25 x 2 mm, spaced at 1200 mm centre to centre along main ‘T’. 74 The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size 24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre& 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) 75 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the costof nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate (RATE=614.20/ SQM) FOR 250MM THICK 76 Appron Drain (150x150 ) sizewith M-150 Class brick workin 1:3 cement and coarse sandmortar F.M.2.5along appron including supply of all materials labour and t&Petc.required for proper completion of work. 77 INTERNAL SANITARY AND WATER SUPPLY WORK 78 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests 79 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked black solid plastic seat and lid 80 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 81 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: a)White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps 82 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. 83 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 32 mm dia 84 Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 85 Providing and fixing white vitreous china flat back half stall urinal of size 580*380*350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in D.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required: Range of Single half stall urinals with 5 litre PV.C. automatic flushing cistern. 86 Providing and fixing PTMT Bottle Trap for Wash basin and sink Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms 87 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 88 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 89 Providing and fixing unplasticised PVC connection pipe with brass unions 45 cm length 15 mm nominal bore 90 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore 91 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore 92 Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm (Rainwater+soil+waste) 93 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. 110 mm diameter 94 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 95 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 96 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 97 110 mm bend 98 110 mm Shoe 99 Providing and fixing of UPVC SWR pipe type -B confirming to IS -13592 including jointing the pipe with rubbing ring ,lubricant and UPVC SWR cupler confirming to IS -14735 ,ALSO Including excavation of trenches cutting of walls and holes and repairing the walls ,floors and refiling the trenches as before but excluding supply and cost of other fitting such as elbow bead ,tee and Y -tee including supply of all materials labour and t&p .Required for proper completion of the work . 100 a) 110mm dia P.V.C. pipe 101 b) 75mm dia P.V.C. pipe 102 Providing and fixing of UPVC SWR door bend confirming to IS-14735. 103 75MM 104 110MM 105 Providing and fixing of UPVC Nahani trap size 100/75mm ,100/90 mm confirming to IS -14735 self cleaning design fixed in pcc 1:2:4 and supply and fixing of 125mm dia heavt duty cp brass jali. 106 Providing and fixing of UPVC SWR cowl confirming to IS-14735. 110MM 107 Providing and fixing of UPVC Plain TEE confirming to IS-14735. 108 75X75X75MM 109 110X110X110MM 110 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 111 15mm dia nominal outer dia pipes 112 20mm dia nominal outer dia pipes 113 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Internal work-Exposed on wall 114 25mm dia nominal bore 115 32mm dia nominal bore 116 Providing and fixing gun metal gate valve with wheel of approved quality. 117 25mm dia nominal bore 118 32mm dia nominal bore 119 Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license]. 120 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete: 25 mm nominal bore 121 EXTERNAL SEWAGE AND WATER SUPPLY PIPE LINE SYSTEM 122 Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required,in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. Pipes, cables etc. exceeding 80 mm dia. But not exceeding 300 mm dia 123 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand :10 graded stone aggregate 40 mm nominal size) up to haunches of S.W.pipes including bed concrete as per standard design. 150 mm diameter S.W. pipe 124 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. 150 mm dia. R.C.C. pipe 125 Providing and fixing square-mouth S.W. gully trap class SP-1 completewith C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be notless than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 150x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 126 Constructing brick masonry manhole with 75 class designation F.P.S. bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4graded stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix 127 (1 cement :4coarse sand: 8 graded stone aggregate 40mm nominal size) inside plasstering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 128 (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. 129 a) Inside size 90x80 cm & 500cm deep including C.I. cover with frame (light duty) total wt. of cover & frame to be not less than 38 Kg (wt. of cover 23 Kg & wt. of frame 15 Kg. 130 Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacturess permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design. 131 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm dia nominal bore 132 Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc.32mm 133 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design With common burnt clay M-150.(non modular) bricks of class designation. 134 SEPTIC TANK 135 Excavation in Foundation in ordinary soil (Loam clay, or sand) including lift upto 1.5 metre (5 fts.) and lead upto 30m (100 fts) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in-charge upto a distance of 30 m. (100 fts) from the foundation trenches. (Rate is including Royality). 136 From 0.00 mt to 1.50 mt 137 1.50mt to 3.0 mt 138 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 139 Brick work common burnt clay F.P.S.(non modular) bricks of class designationM-150 in foundation and plinth in: Cement mortar 1 : 4(1 cement : 4 coarse sand) 140 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttring, finishing and reinforcement- All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 141 Centering & Shuttering for Suspended floors, roofs, landings, balconies and access platform 142 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level: Thermo-Mechanically Treated bars of grade Fe-500D or more. 143 15mm cement plaster on rough side of mix 1:4 (1 cement : 4 coarse sand) including cost of all labour, material T&P etc complete. 144 Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. 145 Providing and fixing C.I. tee at the inlet and outlet of septic tank. 146 Providing & fixing 75mm dia vent pipes. 147 Providing & fixing of 75mm dia cast iron terminal guard. 148 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter 149 SOAK PIT 150 Excavation in Foundation in ordinary soil (Loam clay, or sand) including lift upto 1.5 metre (5 fts.) and lead upto 30m (100 fts) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in-charge upto a distance of 30 m. (100 fts) from the foundation trenches. (Rate is including Royality). 151 From 0.00 mt to 1.50 mt 152 1.50mt to 3.0 mt 153 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 154 Brick work common burnt clay F.P.S.(non modular) bricks of class designationM-150 in foundation and plinth in: Cement mortar 1 : 4(1 cement : 4 coarse sand) 155 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttring, finishing and reinforcement- All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 156 Centering & Shuttering for Suspended floors, roofs, landings, balconies and access platform 157 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level: Thermo-Mechanically Treated bars of grade Fe-500D or more. 158 15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall. 159 Providing & fixing 75mm dia vent pipes. 160 Providing & fixing 100mm dia Drain pipes. 161 Providing & fixing of 75mm dia cast iron terminal guard. 162 Supplying and stacking at site. Over burnt (Jhama) brick aggregate 120 mm to 40 mm 163 ELECTRIFICATION WORKS 164 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 165 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 166 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 167 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 168 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 169 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 170 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 171 4 X 16 sq. mm + 2 X 16 sq. mm earth wire 172 Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 173 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). 174 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 175 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required. 176 Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. 177 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep 178 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 179 4 way (4 + 12), Double door 180 8 way (4 + 24), Double door 181 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 182 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps 183 Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 184 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. 185 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. 186 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 187 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit,safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (toleranceas per IS : 374-2019), THD less than 10%, remote or electronic regulator unit forspeed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 188 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 189 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 190 100 mm wide x 50 mm depth x 1.6 mm thickness. 191 150 mm wide x 50 mm depth x 1.6 mm thickness. 192 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray bends (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 193 100 mm wide x 50 mm depth x 1.6 mm thickness. 194 150 mm wide x 50 mm depth x 1.6 mm thickness. 195 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray Tee (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 196 100 mm wide x 50 mm depth x 1.6 mm thickness. 197 150 mm wide x 50 mm depth x 1.6 mm thickness. 198 Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc)in each phase withtouch type selector switches for different readings,instrument fuses, current transformer etc. 199 The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. 200 Main L.T.Panel 201 Incoming : 202 400 Amp. MCCB-1 No 203 Outgoing : 204 200 Amp. MCCB-1 Nos,100 Amp MCCB- 2 No, & 63 Amp MCCB-1 No 205 Cat. B. Pannel Cubicle Type 206 40 Amp Four pole 207 63 Amp Four pole 208 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way, Double door 209 Supplying and fixing 63 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 63amps C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 210 Supplying and fixing 32-40 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 40 amps C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 211 Supplying and fixing 16-20 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 amps C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 212 Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps C curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 213 Supply and fixing of danger board fabricated from 10 gauge M.S. sheet as per I.E.rules. 214 Supply and laying of 1800mm x 900mm x 12mm thick chequered rubber matting of tested quality. 215 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cablerun shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 216 35 sq. mm 3-1/2 core 217 50 sqmm 3.5 core 218 70 sqmm 3.5 core 219 185 sq. mm 3-1/2 core 220 Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire 221 35 sq. mm 3-1/2 core 222 50 sq. mm 3-1/2 core 223 70sqmm 3.5 core 224 185 sq. mm 3-1/2 core 225 Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. 226 35 sqmm 227 50 sqmm 228 70 sqmm 229 185 sq. mm 3-1/2 core 230 Supply and fixing of 40 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing with body with extended heat sink, diffuser of Polycarbonate meterial and driver set complete in all respect.. Make;-Havells 231 Supply and fixing of recess/ Surface/ Pendent mounting round 10 to 15 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. Cat. AAA 232 Supply & fixing of LED Tube Light with batten suitable for up to 2x22 watt Led tube light fitting including tube Suraface complete in all respect. Cat. AAA 233 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 100 Watt. Confirming to IP 66 protection complete in all respect.Outer sideMake;-Havells 234 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 50 Watt. Confirming to IP 66 protection complete in all respect.Inner sideMake;-Havells 235 Orient electric Exhaust Fan 600 mm Orient electricR (Crompton600MM/900 RPM HEAVY EXHAUST FAN CLASS E) 236 Supply and erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required Exhaust Fan (Havells) 237 Supply and erection of AC 230/250 Volts, 50 Hz Wallfans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required WallFan (Havells) 238 DATA & NETWORKING 239 Supply & laying charges of D-link CAT-6 UTP cable 240 Patch cord D-Link 5m 241 Patch cord D-Link 2m 242 RJ-45 I/O with single module face plate-2NO 243 24 ports network switch D-link 244 24 ports patch panel 245 Cable manager 246 PVC conduct pipe 50MM 247 Floor cutting 248 24 U network rack 249 Termination of CAT-6 cable on I/O and oatch panel(48+48) 250 FIRE FIGHTINGEXTINGUISHER CYLINDER 251 Supply and fixing of fire extinguiser ,ABC Type 4.0 kg capacity (ISI Marked IS : 15683 & TAC approved (complete with initial charge and wall bracket ,along with supply of all materials and labour for proper completion of work 252 Supply and fixing of fire extinguiser ,CO2 Type 4.5 kg capacity (ISI Marked IS : 2878 & TAC approved (complete with initial charge and wall bracket ,along with supply of all materials and labour for proper completion of work. 253 Supply and fixing of fire bucket 9-11 litres capacity with river sand fill supply of all materials and labour for proper completion of work. 254 RAIN WATER HARVESTING 255 Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m. 256 In all kind of soil upto 1.5m depth 257 In all kind of soil upto 1.5m to 3.0m. Depth 258 Providing and laying in cement concrete in 1:4:8 (1 cement :4 coarse sand :8 stone aggregate 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors 259 Brick work with common burnt clay F.P.S. (non modularbrick)bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4coarse sand) 260 Reinforced cement concrete work in beams, suspended floor, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands,plain window sills, staircases and spiral stair cases above plinth level up to the floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1cement: 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregrate 20mm nominal size derived from natural sources). RCC Work in Slab 261 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level thermo-mechnically treated bars 262 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) 263 Supply and stacking of graded stone aggregate of 45-90mm size 264 Supply and stacking ofstone chippings of 11.20mm size 265 Supply and stacking ofmoorum at site 266 Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacturess permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design 267 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter 268 100 mm S.C.I. trap with 100 mm inlet and 100 mm outlet 269 Stoneware pipes grade A (60 cm long) 150 mm dia 270 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m Pipes 80mm to 300mm diameter. 271 Providing, laying and joining glazed stone ware pipes grade Awith stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 272 150mm diameter 273 200mm diameter 274 Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) upto haunches of S.W. Pipes including bed concrete as per standard design. 275 150mm diameterS.W. Pipe 276 200mm diameter 277 Constructing brick masonry chamber for underground C.I. inspectionchamber and bends with bricks in cement mortar 1:4 (1 cement : 4coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slabwith 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 finesand : 10 graded stone aggregate 40 mm nominal size), inside Plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarsesand), finished smooth with a floating coat of neat cement on wallsand bed concrete etc. complete as per standard design :Inside dimensions 455x610 mm and 45 cm deep forsingle pipe line : With common burnt clay F.P.S. (non modular) bricks ofclass designation M-150 278 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitablemethod prescribed in IS: 2800 (part I), including collecting samples fromdifferent strata, preparing and submitting strata chart/ bore log, includinghire & running charges of all equipments, tools, plants & machineriesrequired for the job, all complete as per direction of Engineer -in-charge,beyond 90 metre & upto 150 metre depth below ground level.All types of soil 300 mm dia 279 Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia,conforming to IS: 12818, including required hire and labour charges, fittings& accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia 280 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mmto 2 mm in recharge pit, in required thickness over gravel layer, for all leads& lifts, all complete as per direction of Engineer -in-charge. 281 C.C. ROAD 282 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width aswell as 10 sqm on plan) including disposal of excavated earth, leadupto 50m and lift upto 1.5m, disposed earth to be levelled and neatlyy 283 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 284 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications anddirections of Engineer-in-charge. (The panel shuttering work shall be paid for separately). 285 Brick work with common burnt clay F.P.S. (non modularbrick)bricks of class designation M-150 Cement mortar 1:4 (1 cement : 4 coarse sand) 286 Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads/ pavements all complete as per directionof the Engineer-In-Charge. 287 12 MM thick plaster (1:3) with coarse sand including cost of all labour, material T&P etc complete. 288 CARTED EARTH FILLING 289 Filling of carted earth under floors, including watering, ramming, consolidating and dressing complete. 290 C.C.TV CAMERA 291 Camera and accessories 292 Camera Max 2M 1920 x 1080 resolution 3 point 8mm fixed lens H dot 264 MJPEG dual codec Multiple streaming Day and Night ICR WDR 120dB Enhanced DIS Defog SD SDHC SDXC memory slot Multi crop streaming IR LED, CertificationFCC,YL listed, CE (for installation at indoor areas like court, offices, etc.) 293 5 MP Outdoor Bullet CCTV Ethernet Camera with inbuilt Audio Mic IP67 1080p 294 5MP IR Dome Camera | 3.6mm Fixed Lens up to 20 M IR Distance | Max. 25fps@5MP (16:9 Video Output), White - CP-USC-DC51PL2-V3 MAKE;-Hikvision/CP PLUS 295 Switch 296 Industrial grade Gigabit Switch 16 port-D Link 297 Hardware- Server Room 298 Network Rack 18 U 299 32 LCD screen Smart TV IP Enabled-Make:LG 300 8 TB Hard disk 301 CCTV Software 302 Network Video Software 303 Cables 304 Power Cable 305 Fiber Optic Cable (2Core) 306 CAT5 Cable 307 Project Services and Installation Services 308 REFLECTIVE SIGN BOARD 309 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. 310 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 311 Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulatedlens type heat activated retro reflective sheeting conforming to type - III of ASTM-D-4956-01 as approved by Engineer-in-charge, letters, borders etc. as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineerin- charge.(Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment). Overhead informatory road signage 312 Writing text 313 DG SETPLATFORM 314 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil 315 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 316 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. 317 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) SLAB 318 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 319 Centering and shuttering including strutting, propping etc. and removal of form for Raft Foundation. 320 Brick work with common burnt clay F.P.S. (non modularbrick)bricks of class designation M-150Cement mortar 1:4 (1 cement : 4 coarse sand) 321 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 322 Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 323 V SETSAFETY CAGE/MONKEY CAGE 324 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil 325 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 326 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. 327 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)For Slab 328 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 329 Centering and shuttering including strutting, propping etc. and removal of form for Raft Foundation. 330 Brick work with common burnt clay F.P.S. (non modularbrick)bricks of class designation M-150 . Cement mortar 1:4 (1 cement : 4 coarse sand) 331 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 332 Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 333 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. 334 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 335 SPLIT AIRCONDITIONING SYSTEM 1.5TR 336 Supply & installation of split direct expansion Air conditioners suitable for operation on A/C Supply single phase 50 HZ 230 Volts with hermetically sealed compressor with air cooled condenser ,motor capacitor and startrun capacitor .relay and over load protector internal unit ,with one indoor and one outdoor unit.The condenser unit will be placed outside the room on the terrace to avoid noise including standard lenght of suitable size copper tubing covered with insulation tube .(hIGH WALL CHORDED /CORDLESS ) SUITABLE CAPACITY 3 CORE SHEATHED /PVC COPPER CABLE AND A BATTERY OPERATED WIRELESS REMOTE.VOLTAS /HITACHI /SAMSUNG ETC. Bee star rated :5 star ,EER3.4 337 GST Extra as applicable

Key Value

Document Fees
INR 17700 /-
EMD
INR 584000.0 /-
Tender Value
INR 2.91 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail