Tender For Provision Of Fire Exit Ramp From Icu At Second Floor Of Main Hospital Bldg At Command Hospital (Wc) Chandimandir, chandimandir-Haryana

Tender Notice

52090587
Tender For Provision Of Fire Exit Ramp From Icu At Second Floor Of Main Hospital Bldg At Command Hospital (Wc) Chandimandir
Tender
Indian
Haryana
Chandimandir
17-11-2025

Tender Details

Tender For Provision Of Fire Exit Ramp From Icu At Second Floor Of Main Hospital Bldg At Command Hospital (Wc) Chandimandir; 1 Earth work in excavation by mechanical means in any type of soil (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) includinggetting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in charge 2 Earth work in excavation by mechanical means in any type of soil (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) includinggetting out and disposal of excavated earth lead upto 50 m and lift exceeding 1.5m but not exceeding 3.0m, as directed by Engineer-in charge 3 Earth work in excavation by mechanical means in any type of soil (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) includinggetting out and disposal of excavated earth lead upto 50 m and lift exceeding 3.0m but not exceeding 4.5m, as directed by Engineer-in charge 4 Returning, filling in, including spreading, levelling, watering and well ramming in layersof any type of soil not exceeding 25cm thick all as specified and directed by Engineer - in - Charge. 5 M&L Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete and sub base all as specified and directed by Engineer - in - Charge 6 M & L Reinforced cement concrete M-30 design mix using 20mm graded stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete and the like complete all as specified and directed. 7 M & L Reinforced cement concrete M-30 design mix using 20mm graded stone aggregate as in columns, pillars, piers, posts and struts all as specified and directed by Engineer - in - Charge. 8 M & L Reinforced cement concrete M-30 design mix using 20mm graded stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5mtr clear span etc complete all as specified and directed. 9 M & L Reinforced cement concrete M-30 design mix using 20mm graded stone aggregate as in slabs supported on walls, beams, columns and in shelves, ramp slabs, the like all as specified and directed by Engineer - in - Charge . 10 M & L Reinforced cement concrete M-30 design mix as in chajjas, fins, fascias, louvers, parapets and railing etc and the like all as specified and directed by Engineer - in - Charge. 11 M & L pre-cast RCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in landing, chajjas, shelves, cover slabs and similar articles of any thickness, size or shape including necessary from work, finishing the concrete surfaces fair and even in cement mortar and setting in cement Mortar 1:4complete all as specified and directed by Engineer - in - Charge. 12 M & L form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces of concrete all as specified and directed by Engineer - in - Charge. 13 M & L form work to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surface of concrete all as specified and directed by Engineer - in - Charge. 14 Form work to sides and soffits of floor or roof beams, lintels cantilevers, shelves including supports, over hangs and the like for rough finished surfaces complete all as specified and directed by Engineer – in – Charge. 15 M & L form work to soffits of suspended slabs such as roof slab, ramp slabs, and similar work not exceeding 200mm thick for rough finished surfaces of concrete all as specified and directed by Engineer - in - Charge . 16 Form work to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and directed by Engineer – in – Charge. 17 M & L form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide for rough finished surfaces of concrete all as specified and directed by Engineer - in - Charge. 18 M&L Brick work with sub class B old size burnt bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 all as specified and directed by Engineer - in - Charge . 19 M & L mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia all as specified and directed by Engineer - in - Charge. 20 All as per Srl item No. 19 here in before but 5mm and overfor as in stirrups, spacers and binders all as specified and directed by Engineer - in - Charge. 21 M & L rendering 10mm thick on fair facesof brick work or concrete surfacesin CM 1:6 finished even & fair without using extra cement all as specified and directed by Engineer - in - Charge . 22 M & L 5mm thick rendering in Cement Mortar 1:3 on fair facesof brick work or concrete surfaces finished even and fair without using extra cement complete all as specified and directed by Engineer - in - Charge . 23 M & L rendering 15mm thick on fair facesof brick work or concrete surfacesin CM 1:4 finished even & fair without using extra cement all as specified and directed by Engineer - in - Charge .Note:- The rates do not include for the supply of integral water proofing compound, which shall be paid for in addition at “supplied only rates separately, as applicable. 24 Supply only integral water proofing compound. 25 M & L Sand filling under floors or in foundations including watering and consolidation all as specified and directed by Engineer - in - Charge. 26 M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over plastered or unplastered or concrete surfaces including water proof putty and preparation of new surfaces complete all as specified and as directed by Engineer-in-Charge. 27 M & L three coats ofwhite wash including preparing new plastered or unplastered surfaces of ceiling complete all as specified and directed by Engineer - in - Charge. 28 S & FPVC pipes (SWR) single socketedwith rubber ring joints 110mm dia fixed to wall complete all as specified and directed by Engineer - in - Charge . 29 S&F PVC (SWR) bends any radius bore of 110 mm with access doorall as specified and directed by Engineer - in - Charge 30 Demolition of Reinforced cement concrete (reinforcement cut as required to facilitate demolition) in floors / pavings, (below or above ground level) and of any description and in any position not otherwise specifically provided for all as specified and directed by Engineer - in - Charge . 31 Point wiring complete with 1.5 sq.mm PVC insulated unsheathed multi-stranded FRLSH grade copper conductor 1100 V grade drawn throughand includingnon-metallic rigid 25 mm dia PVC conduit, medium grade, including conduit accessories, concealed in walls/ ceiling and terminated to and including provisionof modular metal flush boxes (made out of 1.6 mm thick MS sheet),modular metal frame plate and white coverfor switches, sockets / regulators etc., including 1.5 Sq.mm PVC insulated unsheathed multi-stranded FRLSH grade copper conductor cable as earth continuity conductor and connecting to common earth dolly with brass screws, washers etc., complete all as specified and directed for one light point controlled by modular switch 6 Amp, single pole, one way, one module, 240V, complete all as specified.Note:-(i) The quoted rate shall deemed to include the cutting chases and making good to match with the existing surfaces. (ii)Modular metal boxes and modular white cover with frame etc is included in quoted rates.(iii) Provn of blank plates as per site requirement. 32 All as per Srl item No. 31 here-in-before but one 05 Amp socket outlet point on independent board controlled by modular switch, 6 Amp, single pole, one way, 240V, complete all as specified and directed. 33 All as per Srl item No. 31 here-in-before but one 05 Amp socket outlet point on same board controlled by modular switch, 6 Amp, single pole, one way, 240V, complete all as specified and directed. 34 S&F modular switch 1 way 6 Amp, 1 module, one way complete all as specified. 35 S&F modular socket 6 Amp, 2/3 pin combined, 2 module complete all as specified. 36 S & F surface mounted (As per site requirement) slim square/roundtype LED panel with die cast aluminium housing and smooth powder coated finish with antiglare UV stabilized diffuser and separate energy efficient eletronic driver having wattage 15 watt LED panel light having dimensions 120x120mm and making connection accessories complete all as specified and directed by Engineer - in – Charge. 37 S & F LED Beacon step light CRCA housing, powder coating with PC diffuser inbuilt IP 65 protection for outdoor appllication, wattage 06 watt rated luminaire efficiancy 110 lm/W, suitable for concealed into surface wall/floor, its super bright LED life span not less than 50000 hours, including LED strip/CDL, driver efficiency > 85% and others accessories as per manufactures recommendation including fixing arrangement complete all as specified and directed by Engineer - in – Charge. 38 S & F MCB distribution board of sheet metal single pole and neutral 8 way, double door, with 200 Amp rated bus bar 240 volt all as specified and directed by Engineer-in- Charge. 39 S&F as in repairs MCB Single Pole and Neutral (SPN) 32-40 Amps, 240 Volt, C Curve with rupturing capacity not less than 10 KA all as specified and directed by Engineer– in– Charge. 40 S&F MCB Single Pole 06-32 Amps, 240 Volt, B Curve with rupturing capacity not less than 10 KA all as specified and directed by Engineer– in– Charge. 41 S & F submain wiring with two single core cables PVC FRLSH insulatedunsheathed 4 Sqmm stranded copper conductor drawn in and including PVC conduitwith and including PVC insulated 4 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in - Charge.Note :PVC cables two single coreand one single core of sizesas mentioned will considered as one unit.

Key Value

Document Fees
INR 500 /-
Tender Value
INR 48.06 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail