}

Tender For Special Repairs To Bldg No T 25 In B Zone Special Repairs To Bldg No T 27 Of Hq 3 Corps Core Mt At Rms, rangapahar-Nagaland

Tender Notice

52090252
Tender For Special Repairs To Bldg No T 25 In B Zone Special Repairs To Bldg No T 27 Of Hq 3 Corps Core Mt At Rms
Tender
Indian
Nagaland
Rangapahar
12-11-2025

Tender Details

Tender For Special Repairs To Bldg No T 25 In B Zone Special Repairs To Bldg No T 27 Of Hq 3 Corps Core Mt At Rms; 1 Demolition of plain cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. 2 M&L for second class hardwood as in scantlings clean sawn timberfixed with and including dismantling of old timber scantlings 40 sqcm and over in section, in unframed work in any position complete all as specified and as directed. 3 All as per Item No 3.00 (here-in-before) but except timber . 4 M & L for plain fillets, square, rectangular or triangular in section clean sawn, secured with nails made out of 2nd class hard wood exc 13and n.exc 25 sqcm complete all as specified and as directed. 5 Demolition of brick work or stone/boulder masonry, built in cement mortar including all quions, arches, pillars ,etc complete all as specified and as directed. 6 Dismantaling of wrought iron or mild steel work of any description complete all as specified and as directed. 7 M&L brick work with sub class B bricks(using old size burnt bricks) straight or curved on plan to any radius in half brick thick walls built in CM (1:4) complete all as specified and as directed. 8 S&Fpre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of old asbestos sheet/plain or corrugated steel sheet complete all as specified and as directed. 9 S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roofcovering /cladding to wall, fixed with self tapping screws including dismantling of old asbestos sheet/plain or corrugated steel sheet complete all as specified and as directed. 10 M&L 15mm thick plastering in CM (1:4) on one side of lathing in two separate layers without using extra cement using water proofing compound @ 3% by weight of cement for finished even and smooth including demolition of reed, lathing single or double, including battens and plaster or chicken wire lathing with and including M&L for GI wire netting 0.71 mm dia and 12 mm mesh lathing in to reed in walls incl all laps cutting and waste complete all as specified and as directed.Note:-WPC will be measured and paid separately. 11 M&L for rendering 12 mm thick in CM (1:6) on other side of lathing finished even and smooth without using extra cement complete all as specified and as directed. 12 S & F 0.71 mm dia wire netting of galvanised steel wire of size 12 mm mesh fixed with tinned tack of wire staple icluding dismantling of chicken wire lathing complete all as specified and as directed. 13 S&F for post of Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) confirming Fe 410 -W (Gde- E- 250) quality- A complete all as specified and as directed. 14 S & F plates (plain or chequered ) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment confirming Fe 410 -W (Gde- E- 250) quality- A complete all as specified and as directed. 15 S&F5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification complete all as specified and as directed. 16 S&F Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications including dismantling of old unsv wall panelling complete all as specified and as directed. 17 S&F anodised aluminium powder coated any colour window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/mincluding necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws complete all as specified and as directed. 18 S&F in repairs for 15mm dia stopvalves,fancy type and chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for Unions and fixed complete all as specified and as directed. 19 S&F in repairs PVC connection 15mm dia and 45cm long with two Nosof brass checknuts and washers complete all as specified and as directed. 20 S&F grating doom 125mm dia with waste hole of PTMT (Min wt 40 gms) complete all as specified and as directed. 21 M&L for applying two coats of oil bound distemper over one coat of primer over a coat of2mm thick wall care putty(in two layers) on new plastered surfaces of walls including preparation of newsurface complete all as specified and as directed. 22 M&L for complete removal of exisitng treatment of old decorated surfaces ofwall applying two coats of oil emulsion distemper over a coat of primer over coat of wall care putty(2mm thick in two layers) for obtained smoothness of wall surfaces complete all as specified andas directed. 23 M&L for factory made 30mm thick 2nd class hardwood plained framed shutter (any nomber of panel) with panel of timber flat on both side or of verneered particle board medium density wood particle board with commercialfaces verneer suplied and fitting to chawkhat complete all as specified and as directed. 24 S&F aluminium anodised grill with mesh size 75 mm and aluminium bar 6 mm XPM type including all accessories such as channels for fixing grill screws etc, aluminium section 15 micron thick anodizing complete all as specified and as directed. 25 S&F 4 mm thick anodised aluminium composite panel fixed in aluminium frame including necessary rubber beading, jointing cleats complete all necessary items to fix with frame and complete all as specified and as directed. 26 S&F Sheet glass 4.8mm thick clear/sun shade colour glass, ordinary quality and glazing with oil putty in squares exceeding 0.5sqm in each pane complete all as specified and as directed. 27 S&F in repair for aluminium (extruded section) bodydoor closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed. 28 S&F in repairsMortice lock,vertical type Brass 2 levers, size 100 mm complete all as specified and as directed. 29 S&F in repair 75 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to floor complete all as specified and as directed. 30 S & F in repairs vitreous china bowl urinal flat back size of 465x355x265 mm white (minimum) with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and as directed. 31 S&F 110mm dia PVC (SWR) bends complete all as specified and as directed. 32 S & F 75mm dia, PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed. 33 M&L for PCC (1:3:6), type C-1, (using 20mm graded stone aggregate) as in coping including necessary formwork complete all as specified and as directed. 34 S&F for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,exc10cm but n exc 15 cm long and 11 to 15 mm dia of neck complete all as specified and as directed. 35 M & L for 25mm thick and 200 mm wide second class hard wood boarding , plained one side with butt joints as ineaves boards including dismantling of old unsv boarding complete all as specified and as directed. 36 M&L for PCC (1:2:4) type B-2 (using 40mm graded stone aggregate) as in foundation, filling and mass concretecomplete all as specified and as directed. 37 S&F 15mm bore Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed. 38 M&L for complete removal of exisitng treatment of old decorated surfaces ofwall applying two coats of exterior weather paint over a coat of primerover a coat of 2mm thick wall care putty(in two layers) onwall surface upto 3 storeyed bldg complete all as specified and as directed. 39 M&L for preparation of new surfaces ofwall and applying two coats of exterior weather paint over a coat of primerover a coat of 2mm thick wall care putty(in two layers) onwall surface upto 3 storeyed bldge complete all as specified and as directed. 40 M&L for preparation of old decorative surfaces of wall by washing rubbing down andtopping of distemper surfaces and applying of one coat of OBD of approved shade/tint complete all as specified and as directed. 41 M&L for complete removal of existing treatment of old decorative surfaces applying two coats of synthetic enamel paint (1st grade)including preparation of old steel surfaces area over 10cm width & girth complete all as specified and as directed. 42 M&L for preparation of new untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink wood primer complete all as specified and as directed. 43 M&L for light shade/coloured vitrified ceramic tiles 9-10mm thick (Square / rectangular) of area exc 0.36 sqm but not exc 0.42 Sqm each, in floors laid over and including 15mm thick screed bedfor laying floor finishes in CM (1:6) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles includingdismantling/demolition of old floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. 44 All as per Item No. 43.00 (here-in-before) but on vertical surfaces such as skirting , dado risers to stepsover and including 10 mm thick bedding layer in CM (1:4). 45 M&L for Non Skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm,in floors laid over and including 15mm thick screed bedin CM (1:6) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles includingdismantling/demolition of old floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. 46 M&L for Glazed ceramic coloured tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tile laid over and including baking coat of 10 mm thick in CM (1:4)includingdismantling/demolition of old floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. 47 M&L for Non Skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm,in floors laid over and including 15mm thick screed bedin CM (1:6) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles includingdismantling/demolition of old floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. 48 All as per Item No. 47.00 (here-in-before) but on vertical surfaces such as skirting , dado risers to stepsover and including 10 mm thick bedding layer in CM (1:4). 49 M&L for Non Skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm,in floors laid over and including 15mm thick screed bedin CM (1:6) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles includingdismantling/demolition of old floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. 50 M & L for PCC 25 mm thick type B-0, (1:2:4) (using 12.5 mm graded stone aggregate)as in levelling course of floor complete all as specified and as directed. 51 M&L for 75 mm thick PCC (1:3:6) type C-2 , (using 40 mm graded stone aggregate) as in plinth protection laid to slope of 1:12, finished fair and even without using extra cement with and including all necessary formwork to divide that area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 10 mm wide joints throughout thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and as directed. 52 S & F for4 mm thick of size 600x600mmHSPC (high pressure Steam Cured) pre-Painted self embossed, textured designer boardE-Board Classic to be fixed Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. fixed in ceiling flat or Sloping including dismantling of old unsv ceiling boards (fibre, pulp, insulation, etc.) any thickness including cover fillets of any description and at any location complete all as specified and as directed. 53 Taking down chowkhat or frames not exc 1.5 Sqm each (without taking off shutter from the frame) complete all as specifed and directed. 54 Taking down chowkhat or frameexc 1.5 sqm not exc 4 sqm each (without taking off shutters from the frame) complete all as specifed and directed. 55 Taking Down shutter of any description exc 1.0 sqm n exc 2 Sqm complete all as specifed and directed. 56 M&L for 2nd class hard wood plain solid straight chowkats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pined joints complete all as specified and directed. 57 S&F factory made 30 mm thick flush shutter, solid core construction, with particle board core and plywood face panels, commercial type on both side fixed to chowkats complete all as specified and as directed. 58 M&L for factory made 30mm thick 2nd class hard woodGlazed and skeleton shutter, open rebated and prepared to receive glass, gauge etc. devided into squares with plain chamfered or rounded, mitred and rebated sash bars edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I Section-8 clause 8.24(a) complete all as specified and as directed. 59 S&F in repair mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 18mm, fixed with tinned tacks or galvanized wire staples complete all as specified and as directed. 60 S&F anodised aluminium powder coated any colour frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing complete all as specified and as directed. 61 S & F aluminium Window and ventilator shutters, without sash bars, aluminium sections weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws complete all as specified and as directed. 62 S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples and fixed with tinned tacks or galvanised wire staples complete all as specified and as directed. 63 S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification complete all as specified and as directed. 64 S&F Factory made solid panel pvc doorshutter 30 mm thick (style) con-sisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be cov-ered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement suppling & fixing at site as per specification complete all as specified and as directed. 65 S&F butt hinges medium grade cold rolled mild steel and fixed size of hinges 100 mm long size complete all as specified and as directed. 66 S&F Aluminium anodised barrel tower bolt of extruded section and fixed 100 mm long complete all as specified and as directed. 67 S&F Aluminium handle cast type anodised 150 mm long complete all as specified and as directed. 68 S&F Aluminium alloy anodised sliding door bolt with hasp and staple (bolt type fixing clips of sheet cast or extruxded section(300 mm long) complete all as specified and as directed. 69 S&F in repair 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate complete specified and directed 70 S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc .50 sqm in each panels complete all as specified and directed. 71 M & L rendering 15 mm thick in cement mortar (1:4) on fair faces of brick or concrete work even and smooth without using extra cement including taking down old plaster from its position complete all as specified and directed. 72 M & L rendering 15 mm thick in cement mortar (1:6) on fair faces of brick or concrete work even and smooth without using extra cement complete all as specified and directed. 73 M & L rendering 15 mm thick in cement mortar (1:4) on fair faces of brick or concrete work even and smooth without using extra cement. 74 M&L for preparation of new plastered surfaces and applying two coats ofcement base paint of approved shade on walls complete all as specified and as directed. 75 M&L for complete removal of existing treatment and applying two coats of distemper oil emulsiion over old treated plastered surface of wallcomplete all as specified and as directed. 76 M&L for complete removal of existing treatment and applying two coats of cement based paint over a coat of primer on old treated plastered surface of wall complete all as specified and as directed. 77 M&L for preparation of old painted wood and wood based surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint in any tintcomplete all as specified and as directed. 78 M&L for preparation of newsurfaces of steel and iron work of any description over 10 cm width or girth not otherwise described andapplying two coatS of synthetic enamel paint over a coat of red oxide primer on new surfaces in any tint complete all as specified and as directed. 79 M&L for preparation of old surfaces of steel and iron work of any description over 10 cm width or girth not otherwise described andapplying one coat of synthetic enamel paintin any tint complete all as specified and as directed. 80 S&F in repairs 15 mm bore GI tube medium grade, galvanised wih all fittings and fixed complete to walls and ceiling or laid on floors complete all as specified and as directed. 81 All as per item No 80.00 here-in-before but fixing only. 82 S&F in repairs 20 mm bore GI tube medium grade, galvanised wih all fittings and fixed complete to walls and ceiling or laid on floors complete all as specified and as directed. 83 All as per item No- 82.00 here-in-before but fixing only. 84 S&F PVC valveless, syphonic action type, flushing cistern, low level,white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed. 85 S&FVitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) and including EWC Seat cover complete all as specified and as directed. 86 Supply only flush pipe of polyethylene of low or high density of PVC 32mm dia for low level cistern complete all as specified and as directed. 87 S&F in repairs CP Health Faucet with 1 mtr metalic Expandable tube & hook complete all as specified and directed. 88 S& FPVCP or S trap of 100mm diacomplete all as specified and as directed. 89 S&F in repairs for 15mm dia of pipe bib tap cast copper alloy, fancy type, chromium plated with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule and fixed as approved by Garrrison Engineer complete all as specified and as directed. 90 S&F in repair soap dish chromium plated stell/stainless steel, approx size 160x160mm x 1mm thick, fixed to walls with plugs & CP brass screws complete all as specified and directed. 91 S&F in repairs 600mm long tubular tower rail brass chromium plated 20mm dia, D type 60cm long fixed with two plugs (Gutties) of 2nd class hard wood embeded in cement mortor 1:3 with MS screws complete all as specified. 92 S& F in repairs 600 mm x 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commerical plywood and fixed to wooden plugs with chromium plated brass screws and cup washers fancy type complete all as specified and as directed. 93 S&F in repairs CP toilet paper holdercomplete all as specified and as directed. 94 S&F in repairs corner glass shelf assembly 250mm radius made of 6mm thick craaylic glass, with CP railing, fixed with suitable rowal plug & screws complete all as specified and as directed. 95 S&F in repairs vitreous china fancy wash basin, size 550 x 400mm white including brackets, and waste coupling & pipe of 32mm dia, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other and fixed complete all as specified and as directed. 96 S&F PVC (SWR) 110 mm dia pipe fixed to wall or laid in floorcomplete all as specified and as directed. 97 S & FPVC (SWR) Bend with any radious of 110 mm diacomplete all as specified and as directed. 98 S & FPVC (SWR) Bend with access door any radious of 75 mm diacomplete all as specified and as directed. 99 M&L for cement concrete type B-1 (1:2:4) (using 20 mm graded stone aggregate) as in surface channels and drains complete all as specified and as directed. 100 M&L for chequered cement concrete tiles of size not less than 300x300x25mm thick laid over and including 15mm thick screed bedin cement mortar (1:6) etc, set, jointed and pointed in neat cement slurry with grey cement and pigments complete all as specified and directed. 101 M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms mouldscomplete all as specified and as directed. 102 M&L for brick work with sub class B bricks(using old size burnt bricks) straight or curved on plan exc 6 m mean radius in CM (1:6) complete all as specified and as directed. 103 S&F in repairs rotational moulded polyethylene 1000 Ltrs Capacity water storage tanksdouble layer (cylindrical vertical with closed top) hoisted and fixed in position in SSR Part-I including ball brass valve, with polythelene float and fly nut complete screwed down for iron pipe of 20 mm dia complete all as specified and as directed. 104 M&L for disconnecting existing tanks capacity exc 500 Ltr & n exc 1000 Ltr, setting asidee (or lowering if required) for repairs, cleaning, etc. and hositing if required reconnecting and re-fixing in position complete all as specified and as directed. 105 M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe 410 -W (Gde-E- 250) quality-A complete all as specified and as directed. 106 S&Fsteelworkintubulartrusses, post, purlinsincludingspecialshapedwasheretc.CompleteusingERWorinductionbuttweldedtubesconformingtoIS1161-1979gradest-240complete all as specified and directed by Engineer - in – Charge 107 M&L for vitreous china squatting pan, Orissa, pattern size 580 x 440 mm white with integral foot rests(excluding flushing cistern and flush pipe)including connection to trap and to flushing pipe, anti-syphonage pipe etc complete including making good to floor complete all as per specified and directed. 108 M&L RCC nominal mix (1:1.5:3) type A-1 (using 20mm graded stone aggregate) in Slabs supported on walls,beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like complete all as specified and directed. 109 Form work with fair finished to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work nexc 200mm thick (horizontal or sloping) complete all as specified and as directed. 110 M& L for 100mm thick PCC (1:4:8) type D-2, (using 40 mm graded stone aggregate ) as in sub base complete all as specified and as directed. 111 S&F in repairsfor Draperly rod /Harrison rails of CP of 20mm dia with fixing brackets , stops, rollers and ringscomplete all as specified and as directed. 112 Material and labour for point wiring in repairs (concealed type) on wall or ceiling forwith 1.5 sqmmPVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts gradecontrolled by one way switchincluding 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for earth continuitywire connected to common earth dolly drawn through and including PVC rigid conduit of adequate sizewith all accessories and the cables will terminate to modular GI box of suitable size and thickness includingModular typeBase / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc.complete all as specified and as directed. (Note: (i) Red, Yellow and Blue coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (ii) payment for cutting chases shall deemed to be included in the quoted rate.) 113 Onelight pointcontrolled by one, one way switch . 114 One Ceiling fan/ exhaust fan point controlled by one, one wayswitch. 115 One 3 pin socket outlet 5 Amps on the same board with other switches. 116 One 3 pin socket outlet 5 Amps on the Independent board. 117 One bell pointcontrolled by one, one way switch . 118 All as per item No- 112.00 here-in-before but with 2.5 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor connected to common earth dolly complete all as specified and as directed. 119 S&F Modular Switch 1 way 6A,1 module complete all as specified and as directed. 120 S&F modular switch 1 way 16A, 1 module complete all as specified and as directed. 121 S&F Modular Socket ,6A/2/3 pin combined 2 modulecomplete all as specified and as directed. 122 S&F Modular Socket ,6A/16A-2/3 pin combined 2 module complete all as specified and as directed. 123 S&F stepped type electronic fan regulator,120 W-2 module complete all as specified and as directed. 124 S&F Modular bell push switch 5 amps piano type flush type complete all as specified and as directed. 125 S&F replacement of Bell AC 230 volts musical type complete all as specified and as directed. 126 M&L for Point wiring in repairs complete with two runs of 1.5 sqmm single core PVC insulated FR-LSH cable1100 volts grade with multi-stranded copper conductors, drawn throughand including PVC double locked Casing & caping including provision of 1.5 sqmm, FR-LSH, PVC insulated copper cable as earth continuity conductor connected to common earth dolly, including PVC rectagular box for mounting switches / sockets / regulators etcof suitable size as required at site complete all as specified and as directed. 127 Onelight/Fan point controlled by one, one way switch . 128 One 3 pin socket outlet 5 Amps on the same board with other switches. 129 One 3 pin socket outlet 5 Amps on the switch socket combination. 130 All as per item No- 121.00 here-in-before but with 2.5 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor connected to common earth dolly complete all as specified and as directed. 131 S&F Switch piano flush type single pole, one way 5Acomplete all as specified and as directed. 132 S&F Socket outlet, 2 in 1, 5 pin 5A flush type complete all as specified and as directed. 133 S&F Switch Socket combination, 2 in 1, 5 pin 6A flush type complete all as specified and as directed. 134 S&F Switch Socket combination, 2 in 1, 5 pin 6A/16A flush type complete all as specified and as directed. 135 S&F stepped type electronic fan regulator 100 Watt socket size flush type on the existing phenolic laminated sheet complete all as specified and as directed. 136 S&F ceiling rose 3 terminal PVC/Polycarbonate isolated body with PVC round/squareblock complete all as specified and directed. 137 M&L for sub main wiring with two runs of4 Sq mm and one run of 4 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn throughand including PVC double locked Casing & caping including taking down old unsv one complete all as specified and as directed. NOTE:- two runs of 4 Sq mm + one run of 4 Sq mm and one run of PVC casing & capping and its accessories of suitable size shall be measured as one unit length 138 M&L for sub main wiring with two runs of 6.0 Sq mm and one run of 6.0 Sq mm for earth wire with multi standard copper conductors FRLSH quality, 1100 volts grade, drawn throughand including non metalic rigid PVC conduit with all conduit accessories (including concealing and making good to the disturbed surfaces of walls, ceiling,floors etc. including making good the disturbed surfaces and paint touch up to match with the existing surface) including taking down old unsv one complete all as specified and as directed. NOTE:- two runs of 6.0 Sq mm + one run of 6.0 Sq mm and one run of PVC Conduit and its accessories of suitable size shall be measured as one unit length. 139 S&F LED light fitting 1 x 20 W (4 FT), wall /surface mounted, integrated type with all accessories internally prewired and including connecting up with twin/three core twisted flexible copper conductor cable of suitable size,flexible hose from ceiling rose to fitting complete all as specified and as directed. 140 S&F LED light fitting 1 x 10 W (2 FT), wall /surface mounted, integrated type with all accessories internally prewired and including connecting up with twin/three core twisted flexible copper conductor cable of suitable size,flexible hose from ceiling rose to fitting complete all as specified and as directed. 141 S&F in repairs/replacement for decorative wall mounted light fitting made up of polycarbonate including 9 watt LED lampwith B-22 base complete all as specified and as directed. 142 Supply , fixing and testing of LED Bldg Security light fitting of capacity 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including 1.2 mtr GI bracket of 25mm bore light grade bent to shape and fixed on wall with metal fastners 2 Nos 10mm dia incl drilling of holes as reqd and connecting up with flexible copper cable of size 0.75 sqmm 3 core from ceiling rose to the light fitting complete all as specified and as directed. 143 Taking down Exh/Ceiling fan of any sweep carefully from its installed position, dismantling complete, cleaning all dust, applying grease for bearing, painting of fans complete with superior quality synthetic enamel paint by spraying including filling cavaties with filler, after cleaning all dust, reassembling the fan and blades,hanging/ fixing the fan in its original position and testing on completion complete all as specified and as directed. 144 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed. 145 Supply and fixing LED luminaire 600 mm x 600 mm, 40/42 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed. 146 Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. 147 S&F in repairs MCB Distribution board double door type SPN 12 way, sheet steel, powder painted, with bus bar neutral link & earth bar etc. and fixing MCBsmaking good the distrubed surfaces of various rating capacity complete all as specified and directed. 148 Supply and fixing for AC starter motor single pole 25 amps 230 volt flushtypecomplete all as specified and as directed. 149 S&F in repairs MCB SPN 40 to 63 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB C series complete all as specified and as directed. 150 S&F in repairs MCB SPN 32 Amp rating 240V, 10KA C curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning MCB DB complete all as specified and as directed. 151 S&F in repairs MCB SP 5-32 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB C series complete all as specified and as directed. 152 S&FDistribution board flush type for connection of cable TV socket including with PVC Conduit pipe andwall chasies cuttingmaking good the distrubed all accessorises etc complete all as specified and as directed. 153 S&F for Distribution board flush type for connection ofTelephone socket including with PVC Conduit pipe andwall chasies cuttingmaking good the distrubed all accessorises etc complete all as specified and as directed. 154 Taking down and refixing of Window/SplitAir conditioner units indoor/outdoor complete with cordless remote control and with inbuilt air ioniser and Plasma filter for better indoor air quality with twin rotary compresser three phase units 415 volts 50 Hz of capacity 1.5 TR With eco friendly refrigerent.Note :-(i) Cutting holes in walls/ Windowof any thickness for installation of AC etc, connection and making good the disturbed surface to match with the existing surface after work shall be done and rate is included in above rate .(iii) Electrical cable required to connect outdoor unit with indoor unit and indoor unit to voltage stabilizer are inclusive of quoted rates.(ii)copper piping/ drain piping are inclusive of quoted rates. 155 S&F in repairs Distribution board double door type (for incoming MCCB 100 Amps 4 Pole & out going MCBs) DPX 4 way, sheet steel, powder painted, with bus bar neutral link & earth bar etc. and fixing only incoming MCCB and MCBs of various rating capacity complete all as specified and as directed. 156 S&F in repairs MCCB 4P, 415 Volts, adjustable type, 100 Amps with breaking capacity 16 KA, suitable for fixing in MCB DB complete all as specified and as directed. 157 M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 35 sq mm, 3.5 core complete all as specified and as directed including taking out old unserviceable cable complete all as specified and as directed.. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items. 158 M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 25 sq mm, 2 core including taking out old unsv cable complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items. 159 Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft/ loose soil complete all as specified and as directed. 160 Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all complete all as specified and as directed. 161 Removing of excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all complete all as specified and as directed. 162 M&L for spread fine river sand in trenches complete all as specified and as directed.NOTE: Punned down thickness shall be measured and paid. 163 M&L for laying brick sub class B old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directed 164 Supply & laying tubes light grade galvanised, with all fittings, fixed complete to walls, poles, ceilings for protection of cables of size 40 mm dia bore including taking out unsv GI tubing complete all as specified and as directed. 165 Supply & laying tubes light grade galvanised, with all fittings, fixed complete to walls, poles, ceilings or laid in floors/ trenches/ road crossing for protection of cables of size 32 mm dia bore including taking out unsv GI tubing complete all as specified and as directed. 166 M&L for earthing complete with galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4 mm dia as earth lead connectd by means of bolts, nuts, washers and check nuts all as shown in electrical plate No 3 of MES SSR Part-I, including testing on completion complete all as specified and as directed. NOTE:- (i)The unit rate shall also included for earth work in hard/ dense soil, PCC (1:3:6) type C1 chamber, CI cover 10 m thick, funnel with GI watering pipe 20mm dia Medium grade, GI protection pipe light grade 15mm dia and wire mesh complete in addition to item No 1 (a) to (e) of preamble (notes) under sub heading earthing, specified on Sl Page No 441 of MES SSRPart-II. (ii)Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.

Key Value

Document Fees
INR 500 /-
Tender Value
INR 48 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail