Tender For Provision Of Otm Accommodation Agniveer At Army Air Defense Centre Gopalpur; 2 Item No 01 A : Design and construction of 180 ORs SM Barrack, Gp of Building II(iii),Storrey D/S, (Plinth Area: 2.0 Sqm) with permanent specification, RCC Framed Construction, Provn of ATT, M-30 Concrete, Provn of Mosquito proofing, Provn of Roof Treatment, exterior emulsion (emulsion paint/ weather coat in External surface finish), OBD in lieu of dry distemper Complete allspecified in soil bearing capacity report, design basis report drawings and tender documents. 3 Item No 01 B: Design and construction of Dinning Hall, Gp of Building III(i),Storrey S/S, (Plinth Area: 2.0 Sqm) with permanent specification, RCC Framed Construction, Provn of ATT, M-30 Concrete, Provn of Mosquito proofing, Provn of Roof Treatment, exterior emulsion (emulsion paint/ weather coat in External surface finish), OBD in lieu of dry distemper Complete allspecified in soil bearing capacity report, design basis report drawings and tender documents. 4 Item No 01C : Design and construction of Cook House, Gp of Building IV(vi),Storrey S/S, (Plinth Area: 2.0 Sqm) with permanent specification, RCC Framed Construction, Provn of ATT, M-30 Concrete, Provn of Mosquito proofing, Provn of Roof Treatment, exterior emulsion (emulsion paint/ weather coat in External surface finish), OBD in lieu of dry distemper Complete allspecified in soil bearing capacity report, design basis report drawings and tender documents.. 5 Sch A Part-II (Internal Electrification)Lump sum price worked out by the contractor for (Internal Electrification) as listed in Schedule A Part-II against the lump sum price inserted by the MES. 6 Sch A Part-III (External Electric Supply)Lump sum price worked out by the contractor for (External Electric Supply) as listed in Schedule A Part-III against the lump sum price inserted by the MES. 7 Sch A Part-IV(External Water supply)Lump sum price worked out by the contractor for (External Water supply) as listed in Schedule A Part-IV against the lump sum price inserted by the MES. 8 Sch A Part-V(Road, Path Curvert)Lump sum price worked out by the contractor for (Road, Path Curvert)as listed in Schedule A Part-V against the lump sum price inserted by the MES. 9 Sch A Part-VI (Fire Fighting)Lump sum price worked out by the contractor for (Fire Fighting) as listed in Schedule A Part-VI against the lump sum price inserted by the MES. 10 Sch A Part-VII(Water Cooler)Lump sum price worked out by the contractor for (Water Cooler) as listed in Schedule A Part-VII against the lump sum price inserted by the MES. 11 Sch A Part-VIII(Hot water supply & Solar Hot water)Lump sum price worked out by the contractor for (Hot water supply & Solar Hot water) as listed in Schedule A Part-VIII against the lump sum price inserted by the MES. 12 Sch A Part-IX(Sewage Disposal) Lump sum price worked out by the contractor for (Sewage Disposal)as listed in Schedule A Part-IX against the lump sum priceinserted by the MES. 13 Sch A Part-X(Area Drainage)Lump sum price worked out by the contractor for (Area Drainage) as listed in Schedule A Part-X against the lump sum price inserted by the MES. 14 Sch A Part-XI(Site Clearance) Lump sum price worked out by the contractor for (Site Clearance)as listed in Schedule A Part-XI against the lump sum priceinserted by the MES. 15 Note for Srl No 2 to 14The percentage above / below the SSR -2020 (part-II) rates shall be derived from the amount quoted by the contractor against Srl No. 2 to 14by comparing it with the amount inserted / pre- priced by the department and the same shall be applicable for the items of respective schedule 16 Schedule A Part-XII (Miscellaneous items of works) 17 INTERNALELECTRIFICATION 18 Item No 02 : Materialand labour for point wiring complete with 1.5 sqmm PVC insulated, FRLSH type, ISI marked,conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCConduit 20 mm dia medium grade(MMS/HMS) andincluding cutting, chasing work at any height and all accessoriesconcealedinwalls / roofs / floors / ceiling etc. 19 flush mountingMS box with top,bottom,side/back wall knockout for conduitentry from any direction made out of 1.60mm thick suitable for fixing of andincludingwhite/Silver/Dark bronzecolour modular blankingplate as per number of switch modules flush mountedfor fixing of modular switches,sockets,fan regulators, blank plate etc and including above mentioned colourmodular plate cover of required modules andincluding 1.5 Sqmm PVC insulated multistranded FRLSH type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade with putty for smooth finishing complete all as specified and directedfor the following:- 20 (a) One light point controlled by one switch. 21 (b) Onefan point controlled by one switch and oneregulator. 22 (c) Oneexhaust fan point controlled by one switch . 23 (d) One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board . 24 (e) One 5 pin 6 amps socket point controlled by one 6 amps switch on same board . 25 (f) One bell/buzzer point controlled by one bell push. 26 (g) One light point controlled by two 2 way switches. 27 Item No 02 : All as per item No.1(d) & (e) above,but point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm complete all as specified and directed for the following:- 28 (a) One 6 pin 16/6 amps socket outlet point controlled by one 16 amps switchon independent board. 29 (b) One 6 pin 16/6 amps socket outlet point controlled by one 16 amps switch on same board. 30 Item No 04 :All as per item No.1 (d) above ,but point wiring with 4.0 sqmm and earth conductor of size 4 sqmm complete all as specified and directed. 31 Item No 05 : Supply & fixingand sheet metal enclosurewith acrylic door type, double door ,415 volts AC,VTPNDB, 4 way,8+12 modules, flush mounting with 200amps copper busbar, 2 neutral/earth bars links and MCCB incomer,and MCB SPN/SP/TPNas outgoing and complete forIP43&54 DBs protection complete all as specified and as directed. Note for item No.22 to 32- MCCB/MCB DBs and MCBs/MCCBs both are used same make only 32 Item No 06 : Material and labour for Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres belowground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipeof 15 mm diafrom earth electrode up to test point or up to 7.5mtr whichever is less by means of GIbolts, nuts, check nuts and washersall as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45 CM,RCC cover 1:2:4 type B1 of size 45X45X6CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required valueincluding removing old item completeall as specified and directed. 33 External Water supply 34 Item No 07 : Supply, laying, jointing & testing of 100 mm dia DI Type K-7 pipe with socket & spigot ends, with cement morter zinc coated out side as per IS 8329/2000 in standard length suitable for and including push on tyton joints with rubber rings, laid in trenches all specified & directed. ( Excavation and earth work, DI Specials will be measured and paid seperately) 35 Item No 08 : M & L for Construction of Brick masonry valve chamberof size 600x600x900mm(internal dimension)chamber depth to be reckoned from the top ofPCC foundation to top of brick wall, includingPCC1:4:8 type D2 in foundation PCC 1:2:4 typeB1 in coping, brick work in cm 1:4, plaster 15 mmthick in CM 1:4 flush pointing externally as thework proceeds, MS Sheet cover 3.00 mm thick with handle and locking arranging and angle ironframe of size (25 x 25 x 5 mm) including paintingwith two coats of synthetic enameled paint over acoat of red oxide primer complete all as specified and directed 36 External Electric supply 37 Item No 09 :Supply, install and commissioning of LT panel board outdoor type,factory fabricated prewired, CPRI aproved, cubical type of appropriate size 1200mm x 1200 mm x 400 mm 9Over all dimension) in door, dust and vermin proof,made out of 50x50x6mm angle iron frame/legs and 3,15 mm thick CRCA sheet with openable shutters on both sides (front & rear), and painting to all steel surfaces internally and externally with two coats of powder coated paint over a coat of red oxide zinc chrome primer suitable for 440 volts, 3 phase 4 wire system enclosed with copper bus bar of 400 amp for R,Y,B phases and 200 amps for neutral, having locking arangementmounted on four legs90cm high (30 cm below ground level and 60 cm aboveground level),embedded in PCC (1:2:4 ) type B2 block each of size 200x200x300mmcomplete all as specified & directed by the Engr-in-Charge to accommodate the following accessories and the panel should have arrangement sufficient space to work easily:- 38 Incomming:- (a)Copper bus bar 350 A for three phase and neutral duly insulated with sleeves of different colour RYB.(b) MCCB 4 Pole 160A 25 KA- 1 Nos. (c) Digital multi functional Panel meter showing V/I.Fq, PF along with CTs ,- 01 Set(d)Indicators lamp LED type RYB 240 volts- 01 Set. Outgoing :-(e) MCCB 4 Pole 125 A 25 KA - 1 Nos (e) MCCB 4 Pole 100 A 25 KA - 1 Nos (f) MCCB4 Pole 40 Amp 25KA- 1Nos (Note : (i)Incoming and outgoing cable shall be fixed with appropriate size of copper thimble.(ii)Apron shall be providedat bottom for protection of cable to avoid entry of vermins, reptiles. (iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands. 39 Item No 10 :Earthing of machinery/equipment Installed at power house/substation, using 32 x 6 mm galvanized MS strip and MS galvanized plate of size 600 x 600 x 6 mm ,as earth electrode 40 Water Cooler 41 Item No 11 : Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for inpur variation between 170 volts to 250 volts with out put voltage stablized at 230 volts with accuracy of + 2.5% and capacity 2 KVA suitable for above water cooler 42 Refrigeration 43 Item No 12 : Supply and installation, commissioning of refrigerator electric driven single phase having capacity 460 ltrs frost free working with non CFC refrigrient and BEE 5 star rating 44 Item No 13 : Supply and installation commissioning of deep freezer glass top electric deiven single phase having capacity 320 ltrs having doubledoor working with non CFC refrigirent and BEE 3 star rating 45 Item No 14 : Supply and fix voltage stablizer for automatic operation, single phase naturally air cooled indoor type and designed for inpur variation between 170 volts to 250 volts with out put voltage stablizer at 230 volts with accuracy of + 2.5 % and capacity 1.0 KVA suitable for Refrigerator 46 Fire Extinguishers system 47 Item No 15 : Supply only if fire extinguiser ISI marked CO2 type Fire Extinguisher 4.5 KG capacity conforming to IS : 15683 : 2006 (old IS : 2878) made from seamless cylinder conforming to IS : 7285 duly approved by chief controller of explosive, Nagpur fitted with ISI Marked controlled valve conforming to IS : 3224, high pressure 1 mtr long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting bracket, suitable for operating between 30 degree centrigrade to 55 dgree centigratem Fire rating class - 138 48 Item No 16 : Supply only of stored pressure fire extinguiser ISI marked powder type fire extinguisher 4 KG capacity suitable for class A, B, C fire consisiting with discharge hose and nozzle of welded cylinder, squeeze lever discharge valve fitted with pressure indicating guage, internal discharge tube, discharge nozzle suspension bracket conforming to IS : 15683 : 2006 (old IS : 2878) duly charged with ISI marked mono ammoniumphosphate base ABC powder conforming to IS : 14609 and pressurized with Nitrogen Gas, suitable for operating between 30 degree centrigade to + 55 degree centigrate, Fire rating class - 1A & 3B 49 Item No 17 : Supply only of fire bucket iron body red colour 10 L capacity for dry sand stored type ISI marked IS : 2546 : 206, complete all as specified and as directed 50 Item No 18 : Supplyonly of fire etinguisher mechanical foam type ISI marked foam (AFFF) type fire extinguisher 9 ltrs capacity fitted with forged brass squeexe lever discharge valve, conforming to IS : 15683 : 2006 complete with initial refill consisiting of ISI marked CO gas cartridge of 60 gms capacity conforming to IS 4647 and ISI marked AFFF conforming to IS : 4989 suitabke for operating between + 50 degree centrigrade, fire rating class - 3A & 34B 51 Thescrew threads at the inlet connection shall match with the threading on the branch pipe,the inlet end shall have a hexagonal head to facilitate screwing of the nozzle on to thebranch pipe with nozzle spanner.End couplings, branch pipes, and nozzles shall conform to IS:903-1985, two hoses of 15 mtr. Lengths with couplings shall be provided with each external (yard) hydrant. One nozzle and one branch pipe with coupling shall be provided with each yard hudrant complete all as specified and directed. 52 Sewage Disposal 53 Item No 19 : Supply and laying DWCPE (SN8) drain pipes 150 mm inner dia (160 mm OD) as per IS 16098 (Part-II) laid in trenches to required slope including all accessories / fittings/ jointing rings , jointing and testing complete all as specified and as directed by Engineer-in - Charge. Note :- Excavation and earthwork for trenches shall be measured and paid seperately under respective items.