}

Tender For Provision Of Defi Md Accommodation For Offers, Jcos And Ors At Bambolim Under Ge Panaji Goa, panaji-Goa

Tender Notice

52089526
Tender For Provision Of Defi Md Accommodation For Offers, Jcos And Ors At Bambolim Under Ge Panaji Goa
Tender
Indian
Goa
Panaji
05-12-2025

Tender Details

Tender For Provision Of Defi Md Accommodation For Offers, Jcos And Ors At Bambolim Under Ge Panaji Goa; 1 SCH A PART-I: BUILDING AND STRUCTURESNote: This schedule ispre-priced by MES and the rate indicated as under Col 5 signifies this fact only 2 Total amount of Sch ‘A’ Part I (Building & Structures) 3 Total amount of Sch ‘A’ Part II (Internal Water supply) 4 Total amount of Sch ‘A’ Part III (Internal Electric Supply) 5 Total amount of Sch ‘A’ Part IV(Road, Path and Culverts) 6 Total amount of Sch ‘A’ Part V (Area Drainage) 7 Total amount of Sch ‘A’ Part VI (Sewage Disposal) 8 Total amount of Sch A Part-VII (Boundary Wall, Chain Link Fencing and Gate) 9 Total amount of Sch A Part-VIII(External Water Supply) 10 Total amount of Sch A Part-IX (External Electric Supply) 11 Total amount of Sch A Part-X(Site Clearance,Excavation and Earthwork) 12 BLANK 13 SCHEDULE A PART-XII (MISC B/R ANDE/M WORKS)Note: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 5 signifies this fact only. 14 S&F LED lights fitting 20 W, 220V, AC ,4 feet tube light fitting, extruded Polycarbonate housing and robust construction LED lighting with lumen output, environmental friendly, energy efficient CRI6500K, P.F. not less than 0.95, fixed on PVC square for mounting the fitting & electrically connecting with three core 23/0.0076 PVC insulated multi stranded copper flexible cable from ceiling rose to light fitting (connector of lamp fitting) and one for earthing complete all as specified and directed. 15 S&F Surface mounted 10 watts 12 feet tube light fitting, extruded Polycarbonate housing and robust construction LED lighting with lumen output, enviormental friendly, energy efficient CRI-6500K, PF not less than 0.95, fixed on PVC square for mounting the fitting & electrically connecting with three core 23/0.0076 PVC insulated multistanded copper flexible cable from ceiling rose to light fitting (connector of lamp fitting) and one for earthing complete all as specified and directed. 16 S&F MCB DB VTPN 6 way, metal double door load line powder coated IP 43 IK-09Protection With provision for 4 Pole MCCBs as incomer and SP/TP MCBS as outgoing complete Provided with insulated vertical phase bars neutral bars with shrouds, earth bars, sticking saddles, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identification labels, fixed on wall duly grouted in solid block wall and induding copper lugs/thimbles duly crimped for connection complete all as specified and directed.Note: (i) MCCB shall be measured & paid separately under appropriate items. 17 S&F Miniature circuit breaker (MCB) single poles and neutral (SPN)/DP current carrying capacity 6 to 32 Amp 240V, 10KA. C curve in and including Copper lugs/thimbles of size as per wire/cable including crimping with suitable size lugs for connection, testing and commissioning complete all as specified and directed. 18 S&F Miniature circuit breaker (MCB) single poles and neutral (SPN)/DP current carrying capacity 40 to 100 Amp 240V, 10KA. C curve in and including Copper lugs /thimbles of size as per wire/cable including crimping with suiable size lugs for connection, testing and commissioning complete all as specified and directed. 19 Supply, laying, testing & commissioning of DI pipe (class K9) 100mm dia spigot/socket ends complete with all fittings as Tee, Bends, tail piece, rubber tyton, joints etc in trenches all as per the direction. 20 Supply, laying, testing & commissioning of DI pipe (class K7) 150mm dia spigot/socket ends complete with all fittings as Tee, Bends, tail piece, rubber tyton, joints etc in trenches all as per the direction. 21 Supply, laying, testing & commissioning of DI pipe (class K7) 100mm dia spigot/socket ends complete with all fittings as Tee, Bends, tail piece, rubber tyton, joints etc in trenches all as per the direction. 22 S&F Ductile iron sluice valve of dia 150mm PN 1.6 conforming to IS 14846/2000, lSI marked with MS spindle and iron wheel head with both ends flanged including jointing material like new rubber gasket/ rubber ring, bolts, and nuts etc and testing after completion including sluice valve with stainless steel spindle and brass check nuts with iron wheel flanged type hole and drilled heavy duty lSI marked class PN-1.6 including rubber insertion 3mm thick, nut boIts gasket washer etc complete. 23 S&F Ductile iron sluice valve of dia 100mm PN 1.6 conforming to IS 14846/2000, lSI marked with MS spindle and iron wheel head with both ends flanged including jointing material like new rubber gasket/ rubber ring, bolts, and nuts etc and testing after completion including sluice valve with stainless steel spindle and brass check nuts with iron wheel flanged type hole and drilled heavy duty lSI marked class PN-1.6 including rubber insertion 3mm thick, nut boIts gasket washer etc complete. 24 S&F Cast Iron Air Valves with two air Outlets, 100 mm dia bore and fixing Up in cast iron water supply mains complete all as specified and directed. 25 M&L Valve chamber of any size, type and construction of brick masonry valve chamber of size 1.20m x 1.20m x 1.20m (internal dimension) with 15cm thick foundation using PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) over 15cm thick hardcore, 23cm thick brick wall built in cement and sand mortar (1:4), 15mm thick internal and external plaster including top of floor in cement and sand mortar 1:3 finished even and smooth, without using extra cement, 6mm thick MS sheet cover with, 50mm x 50mm x 6mm MS angle frame embedded in PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) coping having rectangular hinged opening of size with locking arrangements & handle made out of 25cm dia MS round bar, hold fasts etc applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surface including excavation and earth work in any type of soil and disposal of surplus soil to a distance n.exc 50m complete all as specified and directed. 26 M&L for valve chamber of any size, type and construction of brick masonry valve chamber of size 0.9m x 0.9m x 0.9m (internal dimension) with 15cm thick foundation using PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) over 15cm thick hardcore, 23cm thick brick wall built in cement and sand mortar (1:4), 15mm thick internal and external plaster including top of floor in cement and sand mortar 1 :3 finished even and smooth, without using extra cement, 6mm thick MS sheet cover with, 50mm x 50mm x 6mm MS angle frame embedded in PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) coping having rectangular hinged opening of size with locking arrangements & handle made out of 25cm dia MS round bar, hold fasts etc applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surface including excavation and earth work in any type of soil and disposal of surplus soil to a distance n.exc 50m complete all as specified and directed. 27 M&L Valve chamber of any size, type and construction of brick masonry valve chamber of size 0.6m x 0.6m x 0.6m (internal dimension) with 15cm thick foundation using PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) over 15cm thick hardcore, 23cm thick brick wall built in cement and sand mortar (1:4), 15mm thick internal and external plaster including top of floor in cement and sand mortar 1:3 finished even and smooth, without using extra cement, 6mm thick MS sheet cover with, 50mm x 50mm x 6mm MS angle frame embeded in PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) coping having rectangular hinged opening of size with locking arrangements & handle made out of 25cm dia MS round bar, hold fasts etc applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surface including excavation and earth wotk in any type of soil and disposal of surplus soil to a distance n.exc 50m complete all as specified and directed. 28 M&L Filling of riddle earth/ soil under floors or in foundations including watering and consolidation for bedding of underground cable complete all as specified and directed. 29 Design fabricating supply and erecting connecting,testingtotally enclosed LT cubicle panel board 3 Phase 4 wire system outdoor double door front and back opening type, sloped canopy (Hood) on top extended 100mm aII around, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cables in and out, incoming and outgoing feeders duly marked on reviled plates etc complete CPRI approved factory made fabricated out of 3mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour built in industrial type locking arrangement on front and back ,and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on Angle iron frame of suitable size duly painted and embedded in PCC 1:3:6 45 CM below ground level and 30 Cm above ground level and consisting of following;Location: Main Panel Offr Block. 30 INCOMING(a) MCCB 250 Amps 4 Pole, 25 KA 415 Volt Ics= 100% Icu, Adjustable short circuit setting type (Incoming) -01 No(b) Digital Ammeter 0-250 Amps with CT 250/5A rating - 01 Nos(c) Digital Voltmeter 0-500 volts - 01 Set(d) Indicating lamp (RYB)-01 No OUTGOINGBusbar Chamber: 1 Set (3 L + 1 N) Electrically grade Bus bar aluminium of capacity equal to 1.5 times of rated incoming control switch gear including interconnection of all switch gears duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size:-(a) MCCB 100 Amps 4 Pole, 35 KA, 415 Volt, Ics= 100% Icu, Adjustable short circuit setting type -04 No(b) MCB TPN 10 Amp - 01 No for Street light(c) MCB SP 230 Volts 50 Hz 6 Amps 10 KA - 01No (Timer)(d) Digital Astro Time switch 8A, 240 V AC - 01 No(e) Power contactor 3 pole, 9 A, AC 415 Volts - 01 No 31 Design fabricating supply and erecting, connecting,testingtotally enclosed LT cubicle panel board 3 Phase 4 wire system outdoor double door front and back opening type, sloped canopy (Hood) on top extended 100mm aII around, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cables in and out, incoming and outgoing feeders duly marked on reviled plates etc complete CPRI approved factory made fabricated out of 3mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour built in industrial type locking arrangement on front and back ,and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on Angle iron frame of suitable size duly painted and embedded in PCC 1:3:6 45 CM below ground level and 30 Cm above ground level and consisting of following; Location: (For 3 x Blocks (36 ORs Qtrs at 5 TTR). 32 INCOMING(a) MCCB 250 Amps 4 Pole, 25 KA 415 Volt Ics= 100% Icu, Adjustable short circuit setting type (Incoming) -01 No(b) Digital Ammeter 0-250 Amps with CT 250/5A rating - 01 Nos(c) Digital Voltmeter 0-500 volts - 01 Set(d) Indicating lamp (RYB)-01 No OUTGOINGBusbar Chamber: 1 Set (3 L + 1 N) Electrically grade Bus bar aluminium of capacity equal to 1.5 times of rated incoming control switch gear including interconnection of all switch gears duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size:-(a) MCCB 100 Amps 4 Pole, 35 KA, 415 Volt, Ics= 100% Icu, Adjustable short circuit setting type -03 No(b) Free Space require for MCCB in future - 01 No(c) MCB TPN 10 Amp - 01 No for Street light(d) MCB SP 230 Volts 50 Hz 6 Amps 10 KA - 01No (Timer)(d) Digital Astro Time switch 8A, 240 V AC - 01 No(f) Power contactor 3 pole, 9 A, AC 415 Volts - 01 No 33 Design Fabricating supply and erecting connecting and testing totally enclosed LT cubicle panel board 3 Phase 4 wire system outdoor double door front and back opening type, sloped canopy (Hood) on top extended100mm aII around, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cables in and out, incoming and outgoing feeders duly marked on reviled plates etc complete CPRI approved factory made fabricated out of 3mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour built in industrial type locking arrangement on front and back ,and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on Angle iron frame of suitable size duly painted and embedded in PCC 1:3:6 45 CM below ground level and 30 Cm above ground level and consisting of following; Location: Main Panel No 1 (For 4 x Blocks (64 ORs} and 1x JCOs Block (12 JCOs) at 3 TTR} 34 INCOMING(a) MCCB 630 Amp 4 Pole, 50 KA, 415 Volt, Ics= 100% Icu, Adjustable short circuit setting type -01 No(b) Digital Ammeter 0-600 Amps with CT 800/5 rating - 01 Nos(c) Digital Voltmeter 0-500 volts - 01 Set(d) Indicating lamp (RYB)-01 NoOUT GOINGBusbar Chamber: 1 Set (3 L + 1 N) Electrically grade Bus bar aluminium of capacity equal to 1.5 times of rated incoming control switch gear including interconnection of all switch gears duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size:-(a) MCCB 125 Amp, 4 Pole, 25 KA, 415 Volt, Ics=100% Icu, Adjustable short circuit setting type -05 No(b) MCCB 32 Amp, 4 Pole, 415 Volt, 16 KA, Adjustable short circuit setting type-01 No(c) MCCB 63 Amp, 4 Pole, 415 Volt, 16 KA, Adjustable short circuit setting type-01 No (AMF)(d) MCB TPN 10 Amp-01 No for Street light(e) MCB SP 230 Volts 50 Hz 6 Amps 10 KA-01No (Timer)(f) Free Space require for MCCB in future-01 No(g) Digital Astro Time switch 8A, 240 V AC-01 No(h) Power contactor 3 pole, 9A, AC 415 Volts-01 No 35 Design Fabricating supply and erecting connecting and testing totally enclosed LT cubicle panel board 3 Phase 4 wire system outdoor double door front and back opening type, sloped canopy (Hood) on top extended100mm aII around, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cables in and out, incoming and outgoing feeders duly marked on reviled plates etc complete CPRI approved factory made fabricated out of 3mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour built in industrial type locking arrangement on front and back ,and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on Angle iron frame of suitable size duly painted and embedded in PCC 1:3:6 45 CM below ground level and 30 Cm above ground level and consisting of following. Location: Main Panel No 2 (2x JCOs Block (12 JCOs) at 3 TTR). 36 INCOMING(a) MCCB 63 Amp. 4 Pole, 25 KA, 415 Volt, Ics= 100% Icu, Adjustable Short circuity setting type -01 No(b) Ammeter 0-100 Amps with CT 100/5A rating and selector switch - 01 Nos(c) Digital Voltmeter 0-500 volts - 01 Set(d) Indicating lamp (RYB) - 01 NoOUT GOINGBusbar Chamber: 1 Set (3 L + 1 N) Electrically grade Bus bar aluminium of capacity equal to 1.5 times of rated incoming control switch gear including interconnection of all switch gears duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size-(a) MCCB 32 Amp. 4 Pole, 16 KA, 415 Volt, Ics= 100% Icu. Adjustable short circuit setting type - 02 No(b) MCB TPN 10 Amp - 01 No for Street light(d) MCB SP 230 Volts 50 Hz 6 Amps 10 KA - 01No (Timer)(e) Digital Astro Time switch 8A, 240 VAC - 01 No(f) Power contactor 3 pole, 9A, AC 415 Volts - 01 No(g) Free Space require for MCCB in future - 01 No 37 Design fabricating, supply and erecting connecting and testing totally enclosed LT cubicle panel board 3 Phase 4 wire system outdoor double door front and back opening type, sloped canopy (Hood) on top extended100mm aII around, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cables in and out, incoming and outgoing feeders duly marked on reviled plates etc complete CPRI approved factory made fabricated out of 3mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour built in industrial type locking arrangement on front and back ,and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on Angle iron frame of suitable size duly painted and embedded in PCC 1:3:6 45 CM below ground level and 30 Cm above ground level and consisting of following. Location:Essential Panel for lift. 38 INCOMING(a) MCCB 63 Amp, 4 Pole, 25 KA, 415 Volt, Ics= 100% Icu, Adjustable Short circuity setting type -01 No(b) Ammeter 0-100 Amps with CT 100/5A rating and selector switch - 01 Nos(c) Digital Voltmeter :0-500 volts - 01 Set(d) Indicating lamp (RYB)-01 NoOUT GOINGBusbar Chamber. 1 Set (3L+1N) Electrically grade Bus bar aluminium of capacity equal to 1.5 times of rated incoming control switch gear including interconnection of all switch gears duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size:-(a) MCCB 32 Amp, 4 Pole, 16 KA, 415 Volt, Ics= 100% Icu, Adjustable short circuit setting type -02 No(b) MCB TPN 10 Amp-01 No for Street light(d) MCB SP 230 Volts 50 Hz 6 Amps 10 KA-01No (Timer)(e) Digital Astro Time switch 8A, 240 V AC-01 No(f) Power contactor 3 pole, 9 A, AC 415 Voits-01 No(g) Free Space require for MCCB in future-01 No 39 Supply and fix FRP Loop-in- box on street light pole with suitable bus bar porcelain connector with MCB SP 6 amps, complete all as specified and directed by Engineer in Charge. 40 Material and labour for bracket made out of Gl pipe 40 mm dia medium grade. 1.2 meter long bent to shape fixed with MS flat iron clamps made out of 40mm x 6mm thick nuts boults complete all as specified and directed. 41 Supply, installation, testing and commissioning of free-standing indoor, modular, extendable, 80 kVAr APFC Panel having maintenance friendly semi compartmentalize bolted construction, made out off 1.6 mm thick CRCA sheet and built upon rigid framework, having MPP- HD box type capacitor with 7% aluminium wound reactor units type tested in accordance with fully type tested at an Independent laboratory and conforming to IEC 61439-1&2 and IEC 61921 or IS 16636:2017 with contactor switching,IP 4X protection and including air system provided by axial flow fan or centrifugal fan, control wiring with FR-LSH copper wires complete as specified and directed.The APFC Panel (Capacitor Bank) shall compromise of the following.[i] 160 A, 415 V, Ics = 100% Icu = Icw (1 sec for total selectivity) = 36 kA, 50 Hz electrical draw-out type 3P ACB (with LSI protection), conforming to IS/IEC 60947-2 & 3, with inbuilt release protection, no derating up to 50 °C, microprocessor based trip & LED based display systems with thermal memory providing overload, short-circuit & instantaneous protection, zone selective interlocking, pre-trip alarm & individual fault indicating LEDs, 20 trip record, % loading, bar graph, max. & min. meter and pre-alarm function for Overload & short-circuit - 01 Nos.[ii] High performance microprocessor based APFC relay with 3 CT sensing auto / manual switch option-01 Nos.[iii] MPP-HD box capacitor of 80 (1 X 50 + 2 X 10 + 2 X 5) kVAr[iv] 50 kVAr, 525V - 01 STEP 42 a] 80 A, 415, Ics = 100% Icu = 16 KA, 50 Hz TP MCCB with fixed magnetic settings and adjustable thermal settings- 01 Nos.[b] 3P, 50 kVAr power contactor (capacitor duty), 415 V, 50 Hz 230 VAC coil-01 Nos.[c] 7% detuned reactor, 3- Ph, 50 kVAr, 440 V, 50 Hz- 01 Nos.[v] 10 kVAr, 525V - 02 STEP[a] 20 A, 415, Ics = 100% Icu = 16 KA, 50 Hz TP MCCB with fixed magnetic settings and adjustable thermal settings-01 Nos.[b] 3P, 10 kVAr power contactor (capacitor duty), 415 V, 50 Hz 230 VAC coil-01 Nos.[c] 7% detuned reactor, 3- Ph, 10 kVAr, 440 V, 50 Hz- 01 Nos.[vi] 5 kVAr, 525V - 01 STEP[a] 10 A, 415, Ics = 100% Icu = 16 KA, 50 Hz TP MCCBfixed with magnetic settings and adjustable thermal settings -01 Nos.[b] 3P, 5 kVAr power contactor (capacitor duty), 415 V, 50 Hz 230 VAC coil- 02 Nos.[c] 7% detuned reactor, 3-Ph, 5 kVAr, 440 V, 50 Hz- 02 Nos. 43 NOTES:[i] The APFC Panel shall be sourced directly from the OEM only. The APFC Panel described as above complete in all respect as per specification enclosed, up to the entire satisfaction of engineer-in-charge.[ii] To ensure safety, reliability and accountability of component coordination, all the major capacitor bank components such as capacitor units, de tuning reactors, PF controllers, circuit breakers, contactors and the enclosure system called for in this specification should preferably be from a single manufacturer.[iii] The OEM shall manufacturer APFC components and switchgear. The OEMs specified can not authorize any other partners / sub vendors to manufacture APFC Panels on their behalf. The APFC Panel manufactured by OEMs only will be accepted & factory acceptance test (FAT) will be carried out at OEMs plant only.[iv] The APFC Panel shall have 10% extra space for future expansion. 44 Supply, installation, testing and commissioning of free-standing indoor, modular, extendable, 150 kVAr APFC Panel having maintenance friendly semi compartmentalize bolted construction, made out off 1.6 mm thick CRCA sheet and built upon rigid framework, having MPP- HD box type capacitor with 7% aluminium wound reactor units type tested in accordance with fully type tested at an Independent laboratory and conforming to IEC 61439-1&2 and IEC 61921 or IS 16636:2017 with contactor switching,IP 4X protection and including air system provided by axial flow fan or centrifugal fan, control wiring with FR-LSH copper wires complete as specified and directed.The APFC Panel (Capacitor Bank) shall comprise of the following:[i] 200 A 415 V, 100% (1 sec for total selectivity) = 36 kA, 50 Hz: electrical draw-out type 3P ACB (with LSI protection), conforming to IS/IEC 60947-2 & 3, with inbuilt release protection, no derating up to 50 °C, microprocessor based trip & LED based display systems with thermal memory providing overload, short-circuit & instantaneous protection, zone selective interlocking, pre-trip alarm & individual fault indicating LEDs, 20 trip record, % loading, bar graph, max. & min. meter and pre-alarm function for overload & short-circuit – 01 Nos.[ii] High performance microprocessor based APFC relay: with 3 CT sensing auto/manual switch option – 01 Nos.[iii] MPF HD box capacitor of 150 (2 X 50 + 1 X 25 + 2 x 10 + 1 X 5) kVAr[iv] 50 kVAr, 525V – 02 STEP 45 (a) 80 A, 415 V, 100% Icu = 36 kA, 50 Hz TP MCCB with fixed magnetic settings and adjustable thermal settings – 02 Nos.(b) 3P, 50 kVAr power contactor (capacitor duty), 415 V, 50 Hz 230 VAC coil – 02 Nos.(c) 7% detuned reactor, 3-Ph, 50 kVAr, 440 V, 50 Hz – 02 Nos.[v] 25 kVAr, 525V – 01 STEP(a) 50 A, 415 V, 100% Icu = 25 kA, 50 Hz TP MCCB with fixed magnetic settings and adjustable thermal settings – 01 Nos.(b) 3P, 25 kVAr power contactor (capacitor duty), 415 V, 50 Hz 230 VAC coil – 01 Nos.(c) 7% detuned reactor, 3-Ph, 25 kVAr, 440 V, 50 Hz – 01 Nos.[vi] 10 kVAr, 525V – 02 STEP(a) 20 A, 415 V, 100% Icu = 15 kA, 50 Hz TP MCCB with fixed magnetic settings and adjustable thermal settings – 02 Nos.(b) 3P, 10 kVAr power contactor (capacitor duty), 415 V, 50 Hz 230 VAC coil – 02 Nos.(c) 7% detuned reactor, 3-Ph, 10 kVAr, 440 V, 50 Hz – 02 Nos.[vii] 5 kVAr, 525V – 02 STEP(a) 10 A, 415 V, 100% Icu = 15 kA, 50 Hz TP MCCB with fixed magnetic settings and adjustable thermal settings – 02 Nos.(b) 3P, 5 kVAr power contactor (capacitor duty), 415 V, 50 Hz 230 VAC coil – 02 Nos.(c) 7% detuned reactor, 3-Ph, 5 kVAr, 440 V, 50 Hz – 02 Nos. 46 NOTES:[i] The APFC Panel shall be sourced directly from the OEM only. The APFC Panel described as above complete in all respect as per specification enclosed, up to the entire satisfaction of engineer-in-charge.[ii] To ensure safety, reliability and accountability of component coordination, all the major capacitor bank components such as capacitor units, de tuning reactors, PF controllers, circuit breakers, contactors and the enclosure system called for in this specification should preferably be from a single manufacturer.[iii] The OEM shall manufacturer APFC components and switchgear. The OEMs specified cannot authorize any other partners / sub vendors to manufacture APFC Panels on their behalf. The APFC Panel manufactured by OEMs only will be accepted & factory acceptance test (FAT) will be carried out at OEMs plant only.[iv] The APFC Panel shall have 10% extra space for future expansion. Note: The scope of work in this Sch involves external electrification up to the incoming cable connection of Buildings i.e. up to incoming point of control switch gear. Any other work required for completion of the project which has not been catered in internal and external electrification needs to be completed by contractor without any financial effect. 47 Supply, install, testing & commissioning of silent type Diesel Engine Driven Generating set, 415 Volts, 30KVA/24KW, 3 Phase, 4 Wired, 0.8 Power Factor, 50 Hz, 1500 RPM, excitation screen protected drip proof IP64 enclosure suitable for ambient condition at Bambolim, Goa fully wired Alternator AC for output of 30 KVA continuously directly coupled with diesel engine water/liquid cooled, mounted on common base frame complete with acoustic line & accessories, control panel showing standard parameters of Engine and Alternator, AMF Panel with control cable of suitable size as per DG set capacity, exhaust pipe, fuel tank, anti vibration pads and other standard accessories, conforming to ISO - 8528, IS 1002, BS-5514, IS-4722, 13364, BS EN 60034-1, PCC foundation work as per manufacturers instructions including earth work and comprising of the following complete all as specified and directed: - 48 (A) ALTERNATOR: Standard design alternator rated capacity of 30 KVA/24 KW net output at site after considering derating as per site condition at 0.8 (lagging) power factor, AC, 3 phase, 4 wire, 415 Volts, 50 Hz 1500 RPM, self excited, self regulated with brushless excitation screen protected drip proof IP23 enclosure, brushless design with windings in pole faces, insulation class H, Temp rise Class - H and voltage regulation of +/- 1% at rated voltage from No load to Full load, directly coupled with diesel engine through flexible coupling. The alternator shall be suitable for tropical climate and shall confirm to IS 4722, 13364 and BS EN 60034-1 as amended upto date and shall be in position to generate supply with frequency regulation within +/- 1% tolerance.(B) DIESEL ENGINE: Adequate capacity of Diesel Engine as accepted by the accepting officer based on OEMs technical details water/liquid cooled Diesel Engine to drive independently above the alternator capacity and after considering drating as per site condition after generating and reducing power consumed by accessories directly coupled through flexible coupling, common rail direct injection (CRDI), conforming to BS 5514 and ISO 8528, the engine is prime rated with 10 % over load capacity for one hour in any 12 continuous hours of operation. The engine shall be provided with electrical starting arrangements and shall give the electrical output of 30 KVA at 0.8 power factor, 415 Volts including standard accessories all as specified and required for safe handling and operation. The accessories comprising of following:(i) Radiator with blower fan including guard.(ii) Pipe coupling for engine cooling system piping.(iii) Corrosion inhibitor coolant.(iv) Paper element filters for fuel, Lube oil, Bypass.(v) Flywheel housing and flywheel. 49 (vi) Engine bearing mechanism in flywheel housing.(vii) Dry type air cleaners.(viii) Flexible coupling.(ix) Residential silencer.(x) Stainless steel exhaust flexible bellows.(xi) Electric starter.(xii) Vacuum indicators.(xiii) 12/24 V battery of suitable AH Cap with copper lead, lugs and charging indicator.(xiv) Exhaust piping made out of heavy duty mild steel pipe ‘C’ class of length as per recommendations of OEM to meet CPCB - IV norms inclusive of all accessories and hardware, necessary support steel structure stack including mineral wool insulation 2 inch thick suitable for 400 degree celsius temperature cladded with aluminium sheet for the entire length of exhaust pipe.(xv) First fill lube oil, coolant and diesel during commissioning & testing.(xvi) Silencer: Residential type, Fuel Hoses, Lubricating oil pump, Air Cleaner Dry type, Electronic Governor/ as recommended by OEM.(xvii) Generator Monitoring Panel: comprising of standard items as per standard proactive ignition switch start & stop arrangement, indication for Engine parameters, run meter, RPM meter, Oil pressure indicator, water/ coolant temp indicator, Battery Volt display (State of the art Genset controller), AMF Panel suitable for outdoor installation with all required fixing and safety arrangements. 50 (xviii) Safety Controls: Engine low lub oil pressure, high water temp and over speed of engine.(xix) AVM pads built or separately mounted on manufacturers base frame or as recommended by OEM.(xx) Base Frame: made out of ISMC of sturdy design made of MS channel with necessary reinforcement and predetermined holes.(xxi) Fuel Tank: Daily service fuel tank (as recommended by OEM) with calibrated level indicator, stop cock, drain plug, complete on a common base inside the acoustic enclosure, inbuilt tank with the cap recommended by manufacturer.(xxii) Exhaust gas driven turbo charger and Diesel Exhaust Fluid (DEF) tank of optimized capacity.(xxiii) Fuel injection equipment with electronic governor.(xxiv) Rubber matting of LV grade 19mm thick of suitable size chequered type ISI marked to be laid in front of control panel shall be provided. 51 (xxv) Acoustic Enclosure shall be Powder coated after Pre treatment process, outer body and door made of CRCA sheet of 1.6mm thick, base frame painted with epoxy based black shade sound insulation as per OEM specification to confirm noise level as per CPCB-IV and GRIHA norms, illuminated with suitable cap LED lamp fitting with switch complete as recommended by OEM suitable for above mentioned DG Capacity.(xxvi) NAL approved as CPCB-IV and GRIHA Norms.(xxvii) Batteries and control panel shall be inside the enclosure and capacity should be as per OEM specification.(xxviii) External Emergency stop push button.(xxix) The Noise level shall be 75db max at 1 meter under free field condition.(xxx) The quoted rate shall be deemed to be inclusive of 12 Hrs test run with required qty of Diesel at site including of 1 hour run on 10% overload in presence of representative detailed by Accepting officer and all necessary arrangements are to be made by contractor for test such as artificial load, Fuel and lubricant oil until the successful test. Testing will be carried out till satisfaction of testing officer.(xxxi) Specification & Drawings for PCC foundation as recommended by OEM to be provided by the contractor within above quoted rates. 52 AMF PANEL CONSISTING OF FOLLOWING:(i) Fabricated with CRCA MS sheet, not less than 3.15mm thick with Powder coating, outdoor type panel.(ii) Aluminium Busbar rated for 200A suitable for 3 phase, 4 wire system - 01 Set(iii) Contactor, AC 1 duty, 240V AC coil with Aux contact, 50A, 4 Pole – 2 Nos(iv) MCCB 25KA, 63A, thermal magnetic release O/C, S/C protection with spreader link, 3 Pole – 02 Nos(v) Current transformer with CT ratio 200/5A, 5VA, CL-1.0 – 06 Nos(vi) Indicating Lamp, 240 V, AC/24V DC – 06 Nos(vii) Multifunction meter – 01 No.(viii) VAF meter – 02 No.(ix) DC Ammeter 0-10 A – 01 No.(x) DC Voltmeter 0-20V – 01 No.(xi) Hooter 24 V DC – 01 No.(xii) AMF Controller 3 Ph, 4 wire – 01 No.(xiii) Selector switches 6 A – 02 Nos(xiv) Selector Actuator – 01 No.(xv) EM. Stop with elements – 01 No(xvi) Control Fuse 6.3A – 09 No.(xvii) Control MCB, 10 A, DP – 08 Nos.(xviii) Aux relay 24 V DC, 240 V AC – 08 Nos(xix) Battery Charger as specified by OEM(xx) Neutral link – 01 Set(xxi) Control terminal block 2.5/4 Sqmm – 01 Set 53 (xxii) Control wire – 1/1.5/2.5 Sqmm – as per requirement for complete system to work properly.(xxiii) Gasket 25x3mm – 01 Set(xxiv) Lugs, Ferrules (control) 1/1.5/2.5 sqmm – 01 Set(xxv) Door knobs with open/close striker – 06 Nos(xxvi) PVC Channel Din rail channel 45x45/25x45 – 01 Set(xxvii) Name Plate, Labels & stickers – 01 Set(xxviii) Eye Bolt – 04 Nos(xxix) Bus bar sleeve – 01 Set 54 Design, Fabricate, supply and erecting, connecting and testing totally enclosed LT cubicle panel board 3 phase 4 wire system outdoor double door front and back opening type, sloped canopy (Hood) on top extended 100mm all around, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cables in and out, incoming and out going feeders duly marked on riveted plates etc complete CPRI approved factory made fabricated out of 3mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour, built in industrial type locking arrangement on front and back and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on Angle iron frame of suitable size duly painted and embedded in PCC 1:3:6, 45 CM below ground level and 30 cm above ground level and consisting of following:Location: Near Main Panel No. 1 (For 4 x Blocks (Lift) at 3 TRR) 55 Busbar Chamber: Electrically grade Bus Bar aluminium conductor of capacity equal to 1.5 times of rated incoming control switch gear including interconnection of all switch gears duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of F class insulators made of non-hygroscopic, non-combustible, track resistant high strength FRO insulators for phases and neutral set of 4 for RYB & N – 01 SetINCOMING:(a) MCCB 4 Pole 100 Amps, 415 Volts, 50 Hz, Thermal magnetic adjustable type, rupturing capacity 25 KA – 01 No.(b) Digital VAF multifunction meter including all accessories – 01 No.(c) RYB indicator lamp assembly including LED lamp – 01 No.OUTGOING:(a) MCCB 4 Pole 40 Amps, 415 Volts, 50 Hz, thermal magnetic adjustable type, rupturing capacity 16 KA – 04 Nos.(b) Space for MCCB suitable for 100 Amps 4 pole MCCB – 01 No. 56 Supply and Installation of Smart Single Phase Meter with the following specifications:(a) AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC standards with inbuilt 865-867 MHz Radio Frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry.(b) Meter should support sending the following data to the software: 15/30 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, monthly billing survey for Cumulative Energy and Max Demand.(c) Meter should have connect / disconnect functionality operable from prepaid billing software.(d) The meter should support open communication protocol DLMS with the software.MAKE: Secure, L&T, SchneiderNote:(a) would be possible to run the meter in both prepaid and postpaid mode(b) The meters would carry 5 year warranty.(c)The contractor shall supply weather proof meter protection box of suitable size, IP 65 thermoplastic PS polystyrene with multilevel kncokouts for cable glands of different sizes. The premoudledshall be avialable on the top bottom of the box to enable cable entries from both the directions.Makes:Hensel/Havells/C&S. 57 Supply and Installation of Smart Three Phase Meter with the following specifications:(i) AC Three Phase Four Wire, Tamper Proof, Static Meter of Class 1.0, 415 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC standards with inbuilt 865-867 MHz Radio Frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry.(ii) Meter Should support sending the following data to the software: 15/30 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, monthly billing survey for Cumulative Energy and Max Demand(iii) Meter should have connect / disconnect functionality operable from prepaid billing software(iv) The meter should support open communication protocol DLMS with the softwareMAKE: Secure, L&T, SchneiderNote: (a)The contractor shall supply weather proof meter protection box of suitable size, IP 65 thermoplastic PS polystyrene with multilevel kncokouts for cable glands of different sizes. The premouldedshall be avialable on the top and bottom of the box to enable cable entries from both the directions: Make: Hensel/ Havells/C&S(b) It would be possible to run the meter in both prepaid and postpaid mode(c) The meters would carry 5 year warranty. 58 Supply and Installation of IP-67 protection Data Concentrator Units (DCU) compatible for remote Automatic Metering Infrastructure (AMI) solution and capable of communicating with the smart energy Meter in the corresponding frequency band and with the data server through GPRS/Ethernet. It should have internal memory to store data of at least 200 modules, inbuilt battery back-up, IP-67 protection and should support auto discovery of the meters and self healing mechanism for the breaks in the RF network.Make: Secure, L&T, Schneider, CyanConnode 59 Supply and Configuration of the Web based Software with following modules:(i) Meter Data Management Module:The meter data management module would be responsible for collecting the data from the concentrator and make the data available to the billing system. The meter data management system would capture and provide the following data:(a) 30 min instantaneous data from all the meters for seven parameters – Cumulative Energy, Cumulative Apparent Energy (as applicable), Power, Current, Voltage, Power Factor and Frequency(b) Monthly billing survey data for cum energy and max demand(ii) Postpaid / Prepaid Billing Module:The billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data / billing data available to admin and end users. The billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. It would allow postpaid and prepaid functionality as required.(iii) Occupation and Vacation Module:The system would support occupation / vacation and billing reports.The software would be collecting data from DCU. The software would provide access to staff as well as the occupant for the data.(iv) Web site:There would be a dedicated website for the AGE and BSO team to view all the data and information. The designated users in MES would have the admin access to the application. The MES staff would also have the access of the key information on an android mobiles app (for admin use) 60 (v) Customer PortalThe system would include a customer portal for the resident / occupant to login and view their own energy / billing data. There would be android and iOS mobile apps for the user to monitor its own data and balance on regular basis.(vi) Energy Accounting ModuleThe system would include features of energy accounting. The system would be able to account total energy bloch wise, facility wise and would also allow calculations of unaccounted energy in case total energy meter is also available.(vii) Communication ModuleThe system would provide communication of energy data and bills via print, email and SMS methods.(viii) Meter Master DataThe system would support meter master data repository. The system would support meter replacement process.(ix) Excel ExportThe system would support export of metering and billing data in Excel format. 61 (x) Customer Care ModuleThe software would include a customer care module where the user would be log in any complaints. The service provider would monitor the complaints and carry out the necessary activities for the complaints resolution.(xi) Meter Installation ModuleThe software would include an app-based meter installation module where the meter installation or changes can be captured on the app itself and the readings may be demonstrated to the user if required on the app itself.(xii) Activities CommunicationThe software supports communication of the various activities such as occupation, vacation, meter change, personal detail change etc. with the user as well as the department on email.Make: Schneider, Innologix, SAPNote:The contractor shall supply weather proof meter protection box of suitable size, IP 65 thermoplastic PS polystyrene with multilevel kncokouts for cable glands of different sizes. The premoudledshall be avialable on the top bottom of the box to enable cable entries from both the directions: (a) The software would be hosted either on GCC Server or on MES Server. In case the software is hosted on GCC Server, it would be transferred to MES server whenever the same is made available. (b) The software would contain two year defect liability including all operating expenses such as GPRS charges, hosting charges etc.(c) GE Bank account and one payment gateway would be provided by the MES. The payment gateway would be integrated with the software. 62 Design, manufacture supply, install testing and commissioning 13 passengers lift (884 Kg), speed 1.5 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to As per IS: 14655 (5 parts) latest edition, suitable to serve G + 3 upper floors with AC Variable Voltage & Variable Frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 2D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door) complete all as specified.(i) Rise/Travel (m): Ground + 3 Level(ii) Type of lift: Passenger lift(iii) Load capacity: 884 Kg / 13 Passenger including operator.(iv) Speed: 1.5 Meter per second(v) Power supply: 415 Volts, 3 Phase AC, 50 Hz(vi) Type of drive & Machine: AC variable voltage & variable frequency (VVVF) (GEN2 series-Regenerative Drive) Gearless permanent magnet synchronous motor (including suitable capacity of electrical cabling FRLSH with PVC conduits of suitable size and control & MCB).(vii) Car size: 1100 mm wide X 2000 mm deep x 2200 mm height(viii) Car and landing doors: Center opening, sliding type, stainless steel 304 combination of interlock, mirror & hair line finish for car and landing at all floor. 63 (ix) Car Enclosures: Standard manufacturing with MS Sheet Platform & stainless steel 304 combination of interlock, mirror & hair line finish paneling of 1.2 mm thick (No cladding); with light fitting LED type of 05 watt -04 Nos, Cabin blower with auto start function (incl wiring with suitable stranded copper conductor cable FRLSH), stainless steel false ceiling of 1.2 mm thick, mirror finish, stainless steel hand rail, mirror etc.(x) Terminal buffers: Special PU buffers as per manufacturers design.(xi) Door opening: 900 mm wide x 2000 mm height Centre opening, doors should be of 120 min Fire rating.(xii) Car & CWT guide: Machined Tee for Car & CWT (As per OEM design)(xiii) Signal System: Combined luminous hall push button with (LCD) TFT hall position indicators (IP-55) in ground floor and LED Dot matrix in rest of the floors with stainless steel hairline face plate at all floors two sides.LCD COLOR display Car position indicator in car and over load warning in the car. One No. car operating panel with stainless steel hairline with etched borders and luminous button in car.Car direction indicator in car and landing. Battery operated Alarm bell and Emergency light along with inverter of suitable capacity having fireman switch at ground floor. All signal fixture and COP will have stainless steel face plate.2D infra red sensor safety edge of door for entire height. Built in announcing system without hand set.(xiv) Car indicator: Shall be provided with audio announcing system with music. (xv) Stop and Opening: 4 Stops and 4 Openings all on the same side. (xvi) Emergency services: Automatic Rescue Devices (ARD), to be operating with maintenance free batteries to bring the car to the nearest floor level and auto opening for evacuation of passengers in the event of power failure, Overload Relays, Contactor and Fuses, Electrical terminals of high quality, Limit switch with accessories on each floor, Gravity Counter weight as well as over hoisting/ over lowering limit switches to 64 top most position and Phase sequence corrector, Fire emergency operation, Emergency operation for power failure.(xvii) Traction Media: Flat coated steel belt(xviii) Service function:a. Mischievous call cancellationb. Automatic door time adjustmentc. Floor deselect functiond. Automatic return functione. Car floor button glowf. Interfacing with voice synthesizerg. Emergency battery operated power supply in the event of light failure, this emergency service allows operation of a fan, light and alarm/hooter bellh. Multi beam door sensorj. Nearest landing operationk. Maintenance operation(xix) Operation: Automatic, simplex, selective, Full Collective operation control system with group separation feature with and without attendant, through illuminated pushbutton station located inside the car with provision for locking control in Auto or attendant position. Auto fault detection, Auto fault recording, Next drive, Number of runs indication, Parking operation, overspeed protection, Full load bypass operation, 3 ways intercom.(xx) VVVFD Make: as per OEM(xxi) Control system: 3 precision microprocessor logic control(xxii) Door control: Multi beam door control 65 covering full length of car and landing door, safety door return system.(xxiii) Safety Features: Automatic Rescue Device, Governor safety, Belt Inspection Drive, Infrared door Protection, Emergency Rescue Operation, Overload Warning Device, Emergency alarm Button, Emergency Car light unit, Emergency fireman Service, 3-Way intercom.(xxiv) Advance/ Standard Features: Anti- Nuisance car call Protection, Full load Bypass, Nudging Hoist way access detection, Car call cancelation, Car arrival Chime, 3 Way intercom, Auto fan cut-off, Door time Protection, Door open & closed button, Voice announcement, overload device, Extra Door Time of Lobby & Parking, Manual rescue. 66 Excavation in trenches in soft/ disintegrated rocks not exeeding 1.50m wide and not exeeding 1.5m in depth manual means or mechanical means (hydraulic excavator)for foundation etc or for shafts, wells, cess pits, manholes, pier holes etc not exc 10 Sqm on plan and not exc 1.5 m in depth complete all as specified and directed. 67 Ditto as per item no 16.20 but exceeding 1.5 m and not exceeding 3.00 m deep complete all as specified and directed. 68 Excavation in trenches in any kind of soil not exeeding 1.5m wide and not exeeding 1.5m in depth by manual means or mechanical means (hydraulic excavator) complete all as directed and getting for laying of cable, foundation, pipesetc. 69 Excavation in trenches not exceeding 1.5 m wide and not exeeding 1.5 m depth by manual means or mechanical means (hydraulic excavator) and getting out in hard rock for removing/laying of cables, pipes etc as directed. 70 Excavation in trenches not exceeding 1.5 m wide and but exceeding 1.5 m but not exceeding 3 m in depth and getting out in hard rock for pole excavation as directed. 71 Supply, installation, testing and commissioning of step down transformer, outdoor type, and conforming to IS 1180:2014 (Part 1) amendment 4 of March 2021, plinth mounted HT 11 KV/433-volts, 3 phase 4 wire, 50 Hz, delta/star- connected, vector group DYN -11 double copper wound, ONAN cooling, manual type off load tap changing facility on HT side to vary secondary voltage from minus(-) 7.5% to plus(+) 7.5% in 7 steps of 2.5 %, continuous rating of capacity 160 KVA Level-3 including Cable entry box on HT Side and Cable entry box on LT side. The Transformer shall be completed with all standard fittings and accessories, gauges, first fill of transformer oil IS 335 lSI marked filtered & dehydrated oil etc, complete all as specified and directed and comprising of the following accessories.Note :- Transfomer shall be mounted on platform/plinth. [Loc at new site (Offr Block, 4 x Offrs Qtrs (G+1) & (For 3 x Blocks (36 ORs Qtrs at 5 TTR)].(a) One cable entry box on primary HV side having cable glands suitable for HT XLPE Cable (consisting of 3 Nos porcelain HT bushings with brass/gun metal bushing rods complete with nuts and washers).(b) One cable entry box on secondary (LV) side consisting of 4 Nos porcelain bushing with GM bushing rods complete with GM nuts, and washers with one No cable gland suitable for reception of outgoing LT armoured cables of suitable size.(c) Oil conservator tank with filter type, drain valve and oil level gauge.(d) Dehydrating breather with first fill of dehydrating agent.(e) Thermometer pocket on tank cover. 72 (f) One No 100mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade with temp reading pointer, max temp indicator and resetting device.(g) Rating plate with terminal markings.(h) Two earthing terminals on tank/tank cover to facilitate fixing of 32x6m Gl earth strip.(j) Oil Level gauge.(k) Oil drain and filter valves.(l) Oil filler hole with cap/plug with connections complete.(m) Lifting lugs.(n) Air relief valve plug.(o) Four plan solid cast steel detachable rollers.(p) First fill of fresh oil conforming to relevant IS and tested upto 50 KV dielectric strength upto top of core.(q) Extra bushing for neutral outside the LT cable box for providing independent earthing for neutral.(s) Any other fittings/accessories so as to confirm the whole transformer to IS 1180 Part-1:2014 and Amendment No 4 of Mar 2021, Level-3. 73 Supply, installation, testing and commissioning of step down transformer, outdoor type, and conforming to IS 1180:2014 (Part1) amendment No 4 of Mar 2021, plinth mounted, HT 11 KV, 3 phase 433 volts, 4 wire, 50 Hz, delta/star connected, vector group DYN -11 double copper wound, ONAN, manual type off load tap changing facility on HT side to vary secondary voltage from minus(-) 7.5% to plus (+) 7.5% in steps of 2.5 %, continuous rating of capacity 315 KVA Level-3 including Cable entry box on HT Side and Cable entry box on L T side. The Transformer shall be completed with all standard fittings and accessories, gauges, first fill of transformer oil IS 335 lSI marked filtered & dehydrated oil etc, complete all as specified and directed and comprising of the following accessories.Note :- Transfomer shall be mounted on platform/plinth. [ Loc: (at New Sub stn)(For 3 x JCOs.Blocks (G+1) and 4 x ORs block (G+3), Total12 Nos of JCO Qtr & 64 Nos of ORs Qtr at 3 TTR)].(a) One cable entry box on primary HV side having cable glands suitable for HT XLPE Cable (consisting of 3 Nos porcelain HT bushings with brass/gun metal bushing rods complete with nuts and washers).(b) One cable entry box on secondary (LV) side consisting of 4 Nos porcelain bushing with GM bushing rods complete with GM nuts, and washers with one No cable gland suitable for reception of outgoing LT armoured cables of suitable size.(c) Oil conservator tank with filter type, drain valve and oil level gauge.(d) Dehydrating breather with first fill of dehydrating agent.(e) Thermometer pocket on tank cover.(f) One No 100mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade with temp reading pointer, max temp indicator and resetting device. 74 (g) Rating plate with terminal markings.(h) Two earthing terminals on tank/tank cover to facilitate fixing of 32x6m Gl earth strip.(i) Oil Level gauge.(k) Oil drain and filter valves.(l) Oil filler hole with cap/plug with connections complete.(m) Lifting lugs.(n) Air relief valve plug.(o) Four plan solid cast steel detachable rollers.(p) First fill of fresh oil conforming to relevant IS and tested upto 50 KV dielectric strength upto top of core.(q) Extra bushing for neutral outside the LT cable box for providing independent earthing for neutral.(s) Any other fittings/accessories so as to confirm the whole transformer to IS-1180 Part-1:2014 and Amendment No 4 of 2021, Level-3. 75 S&F Electric chimney, filterless, auto clean type of size 90cm, wall mounted chimney of suction capacity 1250 m3/hr with motion sensor including expandable flexible aluminium duct pipe of 6-inch diameter of sufficient length to connect chimney vent to outside wall, aluminium tape, clamps, cow/cover and other accessories required for installation complete all as specified and as directed.Make: Glen/Faber/Elica/Hindware. 76 S&F Air flow Wave plus, 3 blade, speed level 3 Oscillating Wall Mounted Fan 400 mm sweep complete all as specified and directed. 77 M&L Earthing with 600 x 600 x 6 mm galvanised steel earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5 m below ground level, connected to and including G.l. strip of size 32 x 6 mm dia by means of bolts, nuts and check nuts and washers of galvanised steel, Gl pipe 15 mm dia light grade pipe for protection of Gl earth lead wire both to be provided to the extent of 7.5 metres as earthing lead and connecting to the eqpt/machinery etc. including charcoal dust and common salt packed all around the earth plate in alternate layer in the earth pit all as per electrical plate No. 3 of SSR Part 1-2009 including PCC chamber made up of PCC 1:3:6 type C1 & RCC Chamber cover of size 540 x 540 x 100 mm made with 1:2:4 type B1 using 6 mm round MS bar & 8 mm MS bar for handle , 20 mm dia medium grade G.l. watering pipe from top edge of the earth plate up to M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement including excavation and earth work in any type of soil and testing complete all as specified and directed. 78 Supply, install, testing and commissioning of solar water heater based of indirect transferring of heat of capacity 100 LPD FPC System and with electric backup of suitable wattage and thermostat with necessary wiring and suitable incoming cable, flat plate collectors for cloudy weather ISI marked, all as directed complete with making inlet and outlet water supply connectionas per SWH system 100 LPD FPC or equivalent complete all as specified and directed. Make: Racold/ Luminous/ V Guard or any other make as per Appendix C 79 M&L HDPE DWC Pipe for laying in trenches for cushioning of cable of size 40mm x 32mm complete all as specified and as directed. 80 M&L HDPE DWC Pipe for laying in trenches for cushioning of cable of size 50mm x 38mm complete all as specified and as directed. 81 M&L HDPE DWC Pipe for laying in trenches for cushioning of cable of size 77mm x 63mm complete all as specified and as directed. 82 M&L HDPE DWC Pipe for laying in trenches for cushioning of cable of size 120mm x 103mm complete all as specified and as directed. 83 S&F LED Building Solar street light fitting 20W lithium ferrous phosphate battery mono crystalline panel PIR inbuilt including necessary bracket complete all as specified and directed as per model no HLSSLINTH0901070621-20W-WOP-CWL. Make: Bajaj/ Halonix/ Philips/Crompton or equivalent makes as per Appendix C, 84 S&F TV Cable socket suitable for all types of TV cables complete all as specified and as directed. 85 Supply and install three phase electric meter 60 Amps digital shall comply following specifications.(a) The energy meters must be at least Class 1 with Class CTS/PTs, and should have an active RS-485 port, with industry standard Modbus protocol with publicly available register maps.(b) All water/British thermal unit meters should have an RS-485/RS-232 port with publicly available/industry standard protocol (Modbus, etc.) and register maps.(c) The metering and monitoring hardware and software should support compliance with the relevant requirements of IS/ISO 50001- Energy Management Systems-Requirements with Guidance for Use. 86 SCHEDULE A PART-XIII (Comprehensive Maintainence of Lifts for three years after expire of defects liability period.) Note: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 5 signifies this fact only. 87 Comprehensive maintenance and repair of Passenger lift having capacity 13 passengers (884 Kgs), Speed 1.5 meter per second, with single speed motor 415 Volts, 3 phase, AC 50 Hz supply, conforming to as per IS 14665 (5 parts) latest edition, suitable to serve G+3 upper floors and additional 06 upper floors with AC variable voltage and variable frequency drive (VVVF Drive) complete with all standard accessories, simplex automatic and manual dual controlled operation, with/without attendant, center opening doors with door drive (Electric motor driven mechanism), sliding stainless steel doors, Automatic rescue device (ARD) system, 2D infra red door sensor in full height of door and built in announcing system without handset (03 Nos. one each in car, machine room and near ground floor landing door) complete all as specified and directed. (Location:-BAMBOLIM, GOA) 88 First Year after expiry of defect liability period (i.e for 3rd year) 89 Second Year after expiry of defect liability period (i.e for 4th year) 90 Third Year after expiry of defect liability period (i.e for 5th year)

Key Value

Document Fees
INR 3000 /-
EMD
INR 1500000.0 /-
Tender Value
INR 45.14 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail