| 1 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removingtheexcavatedmaterialuptoadistanceof50m.beyondthebuildingareaand stackingandspreadingasdirected,dewatering,preparingthebedforthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means 21.02 |
| 2 | Excavationforfoundationinhardmurum includingremovingtheexcavatedmaterialupto distanceof50metresbeyondthebuildingareaandstackingandspreadingasdirected, dewatering,preparingthebedforthefoundationandnecessarybackfilling,ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Manual Means 21.05 |
| 3 | Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc)item no 24.01 |
| 4 | Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. Item no 21.38 |
| 5 | Providing and laying in situ /Ready Mixcement concreteM-20of trap / granite /quartzite/ gneiss metalforR.C.C.work infoundationslikeraft,stripfoundations,grillageand footingsofR.C.C.columnsandsteelstanchions etc.includingbailingoutwater, Steel centeringformwork,laying/pumpingcoverblocks,compactionandcuring roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 25.11 |
| 6 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)25.31 |
| 7 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or asdirectedincludingsteelcentering,formwork,coverblocks,laying/pumping, compactionandrougheningthesurfaceifspecialfinishistobeprovidedandcuringetc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 25.50 |
| 8 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite/ quartzite/ gneiss metal for R.C.C.slabs andlandingsasper detaileddesigns anddrawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 25.70 |
| 9 | ProvidingandlayingCastinsitu/ReadyMixcementconcretein M-20oftrap/quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawingsorasdirectedincludingsteelcentering, formwork,steelprops,laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 26.25 |
| 10 | Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting androughening the surface ifspecial finish is to be provided and curing complete. (Excluding reinforcement and structural steel). withfullyautomaticmicroprocessorbasedPLCwithSCADA enabledreversibleDrum Typemixer/concreteBatchmixplant(Panmixer)etc.complete.Withfineaggregate (Crushed sand VSI Grade) 26.05 |
| 11 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Item no 26.33 Bd.F.17, Page No. 306 |
| 12 | Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructureincludingstrikingjoints,rakingoutjoints,wateringandscaffoldingetc. Complete 27.13 |
| 13 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positionsincludingbasecoatof15mmthickincementmortar1:4usingwaterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping thesurfaceofthebasecoatroughtoreceivethesandfacedtreatment6to8mm thickin cementmortar1:4finishingthesurfacebytakingoutgrainsandcuringforfourteendays scaffolding etc.complete. 32.11 |
| 14 | Providinginternalcementplaster12mm thickinsinglecoatincementmortar1:5without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.32.03 |
| 15 | Providing waterproof plaster in W.C. and bath12 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing etc. complete.(Excluding Tiles) (As directed by Engineer in Charge) 31.06 |
| 16 | Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete. 32.15 |
| 17 | Providing and applying white-wash in two coats on old / new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete.36.03 |
| 18 | 36.20 Providing and applying interior wall finish luster of approved make on internal wall surface as detailed below Scrapping the surface with emery paper andwipe clean wall primer with brush withmineralturpentinewithbrush8to10%andoil15to20%withrollerand allowingtodryforaperiod6to8hours.wallputtywithappropriateproportionofwater allowing to dry forperiod4to 6hours.Scrapping withEmerypaper180andwipe clean. Applyingwall primer withbrushwithmineral turpentine 8 to 10% andoil 15 to 20% with rollerScrappingEmerypaper320andwipeclean,interiorwallfinishluster1stcoatwith brush/rubber/spraywithmineralturpentine 7to 9%andOilwithroller19 to 21% After8 hours of activity Applying 2nd coat or wall finish Lustre with mineral turpentine 7 to 9% withbrushandOil withroller 19 to 21% after allowing dry for the period of 6 to 8 hours activity.(With prior approval of S.E.) |
| 19 | Providingandapplying2Coatsofhighqualityacryliccopolymermattapprovedlow VOC emulsion paint of approved shadethat gives smooth, flat and washable and durable finishing of approvedmake. Paint should have good flow levelling property with good colour retention andincanantibacterialproperty.Painthastobeappliedonsmoothanduniformsurface prepared by an acrylic copolymer low VOC & Odour putty. This surface should be primed with water based low VOC acrylic copolymer based primer sealer that has incan antibacterial property.Theworkactivityshouldcoverallaspectsofapplyingpaintsfromsurface preparation,fillingtoerectinganddismantlingofscaffolding,finishingthesurfaceetcas directed by Engineer in charge.48.13 |
| 20 | Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick andrequiredwidthinplain/diamondpatternonbedof1:6C.M.including cementfloat, filling joints with neat cement slurry, curing, polishing and cleaningetc. complete.33.06 |
| 21 | Providing and laying vitrified matt fininsh tileshaving size 590 mm to 605 mm x to 605 mm of8to10mmthicknessandconfirmingIS.15622-2006(GroupBla)ofapprovedmake, shadeandpatternforflooringinrequiredpositionlaidonabedof1:4cementmorar including neat cement float, filling joints, curing and cleaning etc. complete.33.42 |
| 22 | Providing and laying vitrified matt finish tileshaving size 590 mm to 605 mm x to 605 mm of8to10mmthicknessandconfirmingIS.15622-2006(GroupBla)ofapprovedmake, shadeandpatternfordadoandskirtinginrequiredpositionfixedin1:4cementmortar including neat cement float, filling joints, curing and cleaning etc. complete.33.43 |
| 23 | Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade withfullmoulding and three grooved line forthetreadsonbedof1:4Cementmortarincludingfloatfilling jointswithneatcement slurry curing polishing and cleaningetc. complete.33.35 |
| 24 | Providingsillsofrequiredmaterial20mmto25mmthick,onabedofcementmortar1:4 includingcementfloat,fillingjointswithneatcementslurry,curing, mouldingedges, polishing,cleaning complete.b) Granite 33.22 |
| 25 | Providing andfixing frame with/without ventilatorof size as specifiedwithCountrynon teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete.39.02 |
| 26 | Providing and fixing mild steel grill work for windows, ventilators etc. 20 kg/sqm as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Itemno 40.01 |
| 27 | Providing and fixing single or double leaf panelled door shutter excluding frame with glazed openablefanlightshutter35mmthickasperdetaileddrawing consisting panelledvertical styles 100 mm x 35 mm and lock and bottom rail 200 mm x 35 mm and panels 12 mm thick both side commercial ply faced particle board including stainless steel fixtures and fastening and T.W. beading at junctions of panel insertsandasinstructedbytheEngineerinchargeincluding3coatsofoilpaintingetc. complete.39.07 |
| 28 | Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixedwithapprovedwaterproofingcompound.Markingfinishedsurfacewithfalse squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for requiredheight,withdripmouldatthejunctionofplasterandparapetandcuringand covering10yearsGuaranteeagainstleakproofnessonCourtfeestamppaperofRs.500/- including ponding test etc. complete.31.04 |
| 29 | Providing and fixing board displaying information, such as \"Name of work, Tender cost, Name of Contractor, Work completion and liability period etc\", having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge 6.36 |
| 30 | ProvidingandfixingOrissatypewhiteglazedearthenware575mmwaterclosetpan including S trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories etc. complete. 42.33 |
| 31 | Providingandlayingintrenches40mmdai.CPVCpipeincludingnecessaryexcavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line ifnecessary and conveying and stacking the same in PWD chowky or as directed etc. complete.42.65 |
| 32 | Providingandlayingintrenches25mmdai.CPVCpipeincludingnecessaryexcavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line ifnecessary and conveying and stacking the same in PWD chowky or as directed etc. complete.42.63 |
| 33 | Providingandfixing100mmdiastabiliserpipe/P.V.C.soilvent/wastepipeandwith necessary fixtures andfitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.42.52 |
| 34 | Providing and fixing 10 cm PVC nahani trap with grating etc. complete.42.67 |
| 35 | Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. |
| 36 | Providing and fixing H.D.P container one piece moulded water tank made out oflowdensitypolythylerandbuiltcorrugationincludingofdeliveryuptodestination hoisting andfixing of accessories such as inlet, outlet overflow of alltanks capacityabove 1000 to 20,000 litres 42.54 |
| 37 | Royalty Charges For Other Material |
| 38 | Material Testing Charges |
| 39 | Insurance @ 0.5% |