}

Tender For 2. Construction Of One Room At Abkari Office Campus. - Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5 M In Width As Well As 10 Sqm On Plan Including Getting Out And Disposal Of Excavated Earth Upto 50 M And Lift, Muzaffarnagar-Uttar Pradesh

Tender Notice

52064778
Tender For 2. Construction Of One Room At Abkari Office Campus. - Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5 M In Width As Well As 10 Sqm On Plan Including Getting Out And Disposal Of Excavated Earth Upto 50 M And Lift
Tender
Indian
Uttar Pradesh
Muzaffarnagar
06-11-2025

Tender Details

Tender For 2. Construction Of One Room At Abkari Office Campus. - Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by engineer in charge. All kinds of soil 0 to 0.30 m As per DSR No 2.6.1 But Excluding G.S.T. 2 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. As per DSR No 2.27 But Excluding G.S.T. 3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) As per DSR No 4.1.8 But Excluding G.S.T. 4 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). As per DSR No 5.1.2 But Excluding G.S.T. 5 Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete. As per DSR No 5.9.1 But Excluding G.S.T. 6 Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform. As per DSR No 5.9.3 But Excluding G.S.T. 7 Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers. As per DSR No 5.9.5 But Excluding G.S.T. 8 Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts. As per DSR No 5.9.6 But Excluding G.S.T. 9 Centering and shuttering including strutting, propping etc. and removal of form for :Weather shade, Chajjas, corbels etc., including edges. As per DSR No 5.9.19 But Excluding G.S.T. 10 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement: 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. As per DSR No 2.35.3.1 But Excluding G.S.T. 11 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). As per DSR No 5.2.2 But Excluding G.S.T. 12 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).As per DSR No 5.3 But Excluding G.S.T. 13 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.As per DSR No 5.22A.6 But Excluding G.S.T. 14 Brick Work with common burnt clay ( non modular) bricks of class - 150 in foundation and plinth in: Cement mortar 1:6 ( 1 cement : 6 coarse sand). As per DSR No 6.1.2 But Excluding G.S.T. 15 Brick Work with common burnt clay ( non modular) bricks of class - 150 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:6 ( 1 cement : 6 coarse sand)As per DSR No 6.4.2 But Excluding G.S.T. 16 2.50 cm thick Damp Proof Course with Cement and approved coarse sand 1:2 with and including water proofing compound (1 Ltr. to 1 bag of cement of 50 Kg.) as ordered by the Engineer incharge in the proportion as specified by the manufacturer including supply of all materials, labour, Tools & plants etc. required for proper completion of the work and including proper curing & shutterings as necessary. As per SOR No 361 But Excluding G.S.T. 17 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.As per DSR No 4.13 But Excluding G.S.T. 18 12 mm thick plaster with cement mortar in consisting of 1:6 cement and approved coarse sand. On smooth surface of wall.As per DSR No 13.4.2 But Excluding G.S.T. 19 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.As per DSR No 4.17 But Excluding G.S.T. 20 Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile E Fixing with adjustable lugs with split end tail to each jamb. As per DSR No 10.14.1.1 But Excluding G.S.T. 21 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats,square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding. As per DSR No 9.48.1 But Excluding G.S.T. 22 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately)35mm thick sutter. As per DSR No 9.5.1.1 But Excluding G.S.T. 23 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm. As per DSR No 11.41A.3.1 But Excluding G.S.T. 24 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.As per DSR No 8.31 But Excluding G.S.T. 25 Providing and fixing aluminium tee channels (heavy duty) with rollers & stop end in pelmets as curtain rod.As per DSR No 9.104 But Excluding G.S.T. 26 Providing and fixing aluminium sliding door bolts lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete:300x16 mm As per DSR No 9.96.1 But Excluding G.S.T. 27 Providing and fixing aluminium tower bolts lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:200x10 mm. As per DSR No 9.97.3 But Excluding G.S.T. 28 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.125 mm. As per DSR No 9.81.1 But Excluding G.S.T. 29 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.100 mm As per DSR No 9.82 But Excluding G.S.T. 30 Providing and applying of plaster of paris puty of2mm thick over plastered surface i/c asper DSR 13.26 As per DSR No 13.26 But Excluding G.S.T. 31 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.As per DSR No 13.80 But Excluding G.S.T. 32 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). As per DSR No 13.47.1 But Excluding G.S.T. 33 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. As per DSR No 13.48.3 But Excluding G.S.T. 34 Pdg. gola 75x75 mm in cement concrete 1:2:4including finishing with cement mortar 1:3.: In 75x75mm deep chase. As per DSR No 12.21.1 But Excluding G.S.T. 35 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm.As per DSR No 22.7.1 But Excluding G.S.T. As per DSR No 22.7 But Excluding G.S.T. 36 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.As per DSR No 12.22 But Excluding G.S.T. 37 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required Group C As Per DSR No 1.10 But Excluding G.S.T. 38 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium.class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required As Per DSR No 1.5 But Excluding G.S.T. 39 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. As Per DSR No 1.7.1 But Excluding G.S.T. 40 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 2 X 4 sq. mm earth wire As Per DSR No 1.7.3 But Excluding G.S.T. 41 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making| good the same in case of recessed conduit as required. 25 mm As Per DSR No 1.21.2 But Excluding G.S.T. 42 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required75 mm X 75 mm X 60 mm deep As per DSR No 1.22.1 But Excluding G.S.T. 43 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required180 mm X 100 mm X 60 mm deep As per DSR No 1.22.5 But Excluding G.S.T. 44 Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch. As per DSR No 1.24.1 But Excluding G.S.T. 45 Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amps Socket As per DSR No 1.24.3 But Excluding G.S.T. 46 Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amps Socket. As per DSR No 1.24.4. But Excluding G.S.T. 47 Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 A socket outlet As per DSR No 1.24.5 But Excluding G.S.T. 48 Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plateAs per DSR No 1.25 But Excluding G.S.T. 49 Supplying and flxing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. As PerDSR No 1.26 Excluding GST 50 Supplying and fixing following size/ modules, Gl alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mm x 75mm). As Per DSR NO 1.27.1Excluding GST 51 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole. As Per DSR NO 2.10.1Excluding GST 52 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4+12), Double door. As per DSR No 2.4.1 But Excluding G.S.T. 53 Supplying and fixing following rating, Two pole, 240 V, isolator in theexisting MCB DB complete withconnections, testing andcommissioninQ etc. as required 40 amp. As per DSR No 2.12.1 But Excluding G.S.T. 54 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speedcontrol and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. As per DSR No 19.10 But Excluding G.S.T. 55 SF of LED tube light batten fitting suitable for UP to 1 X 22 watt LED Tube light complete including tube etc on surface complete in all respect SI No. 1413 A Cat AAA

Key Value

Document Fees
INR 857 /-
EMD
INR 102000.0 /-
Tender Value
INR 10.20 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail