Tender For Provision Of One Additional Room In Ao (R&D) Office At Defence Laboratory, Jodhpur; 1 Surface Excavation not exceeding 30 Cm deep and averaging 15 Cm deep and getting out in Soft/ Loose soil 2 Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes,etc. not exc. 10 Sqm on plan and getting out in any type of soil complete all as specified and directed. 3 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed. 4 Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed. 5 M & L broken stone hard core of gauge n. exc. 63 mm deposited, spread and levelled in layers n. exc. 15 cm thick, watered and rolled / rammed to a true surfaces complete. 6 M&L of earth filling under floor well ramming including watering as required Spreading & leveling in layers n.exc. 25cm thick 7 M&L plain cement concrete (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in foundation, filling and mass concrete all as specified & directed. 8 M&L 40 mm thick Cement concrete type B-1 using 1:2:4 (20mm graded stone aggregate) as in floor complete all as specified and directed. 9 M&L for RCC(1:11/2:3) (Nominal Mix) (using 20 mm graded aggregate) as in foundations , including rafts , footings , foundation beams, Plinth beams,bases for columns etc , basement slabs , under reamed piles and mass concrete. 10 M&L for RCC (1:11/2:3) (Nominal Mix) (using 20mm graded aggregate) as in columns, pillars, piers, posts and struts 11 M&L for RCC (1:11/2:3) (Nominal Mix) (Using 20 mm graded aggregate) as in beams, cantilvers, bressummers, lintels over 1.5m span. 12 M&L for RCC (1:11/2:3) (Nominal Mix) (using 20mm graded aggregate) as in chajjas 13 M&L for RCC (1:11/2:3) (Nominal Mix) (20 mm graded aggregate) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like. 14 Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter. 15 Use and waste of formwork to sides of pillars posts, struts, piers, columns and stanchions finished the suface rough. 16 Use and waste of formwork to sides and soffits of floors or roof beams, beams haunchings, girders,bressummers lintels, cantilevers, shelves including supports overhangs etc also splays between floors and beams etc. 17 Use and waste of formwork to chajjas, troughts and similar items including edges. 18 M&L form work with fair finished to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work nexc 200mm thick (horizontal or sloping) 19 M&L for Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including rubbing and polishing i/c screed bed or bedding layer 20 mm thick in CM 1:6 complete all as specified and directed. 20 M&L for Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm as in skirting & dado and jointed with grey cement slurry mixed with pigments to match the shade including 10 mm thick screed /rendering in CM 1:4complete. 21 M&L for20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of granite complete all as specified and directed. 22 S&F Mild steel TMT bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality . 23 Ditto, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders 24 M&L for Walling of random rubble,uncoursed, well bonded, bedded and solidly hearted, built in, built in CM(1:6) complete as specified & directed. 25 M&L Pre-cast cement concrete block masonry with solid blocks type C1 (1:3:6) , exc. 10 cm in width and setting in CM 1:6 , complete 26 M&L for rendering 15 mm thick plaster in CM 1:6 on stone masonry surfaces or faces other than fair faces of brick or concrete work finished the surface fair and even without using extra cement. 27 M & L for finishing 2 mm thick birla white wall putty over new plaster surfaces of wall all as specified and directed. 28 M&L two coat of oil bound distemper emulsion over a coat of primer on finished surfaces of wall incl preparing of surfaces complete all as specified and directed. 29 M&L rendering 10 mm thick on ceiling surfaces of concrete in CM 1:3 including finishing the surface even and smooth without using extra cement complete all as specified and directed. 30 M&Lpreparing newly plastered or previously untreated ceiling surface and applying two coats of distemper oil emulsion of any tint over a coat of primer complete all as specified and directed. 31 M&L for rendering 15mm thick plaster in CM 1:4 mixed with water proofing compound @ 3% by weight of cement on fair faces of brick or concrete work finished the surface even and smooth without using extra cement. 32 M&L for preparation of new plastered surfaces/ Stone Surfaces and applying two coats ofcement base paint over a coat of alkali resistant primer on walls all as specified & directed. 33 M&L cement concrete 1:3:6 type C-2 (using 40mm graded aggregate) 75 mm thick as in plinth protection/paths surface finished even and smooth without using extra cement. 34 S&F Powder coated (minimum thickness of powder coating 50 micron) aluminium frame for doors,windows,ventilators with one or more rebated including jointing cleat for fixing etc complete all as specified and directed by Engineer in charge. 35 S&F Powder coated (minimum thickness of powder coating 50 micron) Aluminium door shutters,aluminium section weighting 0.55Kg/m including necessary joint cleats,glazing clips,rubber neoprene packing,handles 2 Nos in each door,hinges, powder coated aluminium snap beading screws etccomplete all as specified and directed. 36 S&F Powder coated (minimum thickness of powder coating 50 micron) aluminium window and ventilator shutters,side hung type without sash bars,aluminium sections weight not less than 0.55 Kg/Rm including jointing cleats aluminium snap beading/screws, powder coated aluminium fittings such as peg stays 150mm long (1 Nos),hinges type B-21 100 mm long(2Nos) suitable handle (1 Nos)complete all as specified and directed. 37 Providing and fixing Powder coated (minimum thickness of powder coating 50 micron) aluminium grill of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved powder coated aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge. (Only weight of grill to be measured for payment). 38 Providing and fixing 4 mm thick Metal Composite Panel fixed in aluminum doors and partition frames with EPDM rubber / neoprene gasket etc. (Cost of aluminium snap beading shall be paid in basic item) MCP (Metal Composite Panel) Product Description(a) Panel Thickness 4 mm thick(b) Top/Bottom Aluminium Sheet 0.25 mm(c) Core Thickness 5.5 mm(d) Core Type LDPE(e) Minimum Weight Kg/m2 6.8 Kg/Sqm 39 S&F 4.80 mm thick sheet glass, ordinary quality and glazing in squares area not exceeding 0.5 Sqm in each pane for aluminium door/window shutterscomplete all as specified & directed. 40 S&F 4.80 mm thick sheet glass, ordinary quality and glazing in squares area exceeding 0.5 Sqm in each pane for aluminium door/window shutterscomplete all as specified & directed. 41 S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples 42 M&L Double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box,main body with stainless steel cover,governing pivot made of brass,other parts made of mild steel heavy duty and fixed including taking old unserviceable floor door spring complete all as specified and directed. 43 S&F aluminium anodised handles 150 mm long fixed to doors all as specified and directed. 44 S&F aluminium anodised tower bolts200 mm long fixed to doors all as spescified and directed. 45 S&F 250mm long alluminium alloy anodised, sliding door bolt with hasp,staple (bolt type) and fix clips of sheet,cast of extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy all as specified and directed. 46 S&F 140mm floor door stoper of aluminium alloy body and tongue, anodised, fixed in floor. 47 M&L for 10 mm thick screed bed or bedding layer in CM 1:3 mixed with water proofing compound @ 3 % by weight of cement on concrete roof surface finished fair and even to maintain the proper slope of roof surface etc complete all as specified and directed. 48 (i) Surface prepration :The surface to be treated should be sound and free from all types of dirt, dust and debris. Clean surface by brushing, scraping or chipping to eliminate all defective materials and foreign matter. Proper surface preparation needs dry mechanical grinding to expose base Substrate. Making of angle fillets(75mm*75mm) all around the periphery of the wall with polymer modified mortar using SBR Latex Plus.(ii) Construction joints :All construction joints and cracks >1mm shall be treated by cutting V groove and filling with polymer modified SBR Latex and reinforced with geotextile membrane dipped in PU liquid Membrane before the 1st coat application.(iii) Water proofing membrane : S&F Waterproofingmembrane:Supplying and applying water-based ,single component UV resistant elastomeric PU liquid membrane coatingapplied with brush/roller having SRI >109 with an elongation of >400% and tensile strength of 1.4 MPa as per ASTM D 412, 80 % Solid Content, shore A Hardness of min. 50 as per ASTM D 2240. The system includes final base preparation as per note given below, applying Home Sheild PU ELASTOSEAL BTD or approved equivalent in three coats at 2.8 kg per Sqm providing 1.5 mm DFT , complete as per Manufacturer specifications. Waterproofing membrane to be terminated on parapet wall in a V groove of size 25 mm x 25 mm atleast 300mm aboveFFL whichshould be sealed with Polymer Mortar Complete all as specified and directed. The application will be executed by company authorised applicator upon verification from the company.Make : Berger, Sika, Fosroc. 49 Supply only Liquid water proofing compound 50 Material and labour for concealed point wiring for modular fittings complete with 1.5 sq mm single core multistranded copper conductor PVC FRLS FRinsulated unsheathed 1100 Volt grade cable in and incl concealed PVC Conduit (ISI Marked) with accessories including modular MS sunken box with plate cover with 1.50 sq mm insulated unsheathed PVC FRLS multistranded covered copper conductor for common earth and connecting to earth dolly for :- 51 (a)One light point controlled by one switch one way 52 (b)One fan point controlled by one switch one way 53 (c)One socket out let 5 Amps 5 Pin on same board with other switch 54 (d)One socket out let 5 Amps 5 pin on independent board 55 All as per item No 1 here in before but with cable size 4.0 Sq mm for one 6 pin 16 Amps socket out let on independent board for geyser with multistrand insulated copper earth continuity conductor of size 4.0 sqmm all as specified and directed by Engr-in-Charge.( circuit to be laid seperatly ) 56 Supply and fixing modular switch 6 Amps single module one way. 57 Supply and fixing modular socket 6 Amps 5 pin double module. 58 Supply and fixing modular switch 16 Amps double module 59 Supply and fixing modular socket 6&16 Amps 5 pin double module. 60 Supply and fixing for ceiling rose , 3 pin/pvc/polycarbonate, isolated body complete all as specified and directed by engineer-in-charge. 61 Supply and fixing modular fan regulator, step type, two module 62 S&F LED Tube light1 X 20 watt (04 feet), decorative ultra slim type, with inegral driver, complete with all accessories and making necessary electric connection from ceiling rose to fitting terminal, complete all as specified and directed. 63 Supply and fix ceiling fan of 1200 mm sweep, BEE 5 star rated, 3 nos blades, 30 cm long down rod, 2 nos. canopies, copper winding, all remaining accessories including safety pin, nut bolts, washers, suitable for 230 V, 50 Hz, single phase AC complete all as specified and directed by engineer-in-charge. 64 Supply, fixing, connecting & testing sheet metal enclosures double door, single pole and neutral, 08 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating with IP-42 protection complete, all as specifiedanddirectedby engineer-in-charge. 65 Supply and fixing SP 6 to 32 Amp rating 240V, 10KA C curve MCB inthe MCB DBwith connection testing and commissioning complete all as specified and directed by Engr-in-Charge. 66 S&F MCB 240 volts SPN 32 amp 10KA breaking, capacity, ISI marked, complete all as specifiedanddirectedby engineer-in-charge. 67 M&L for sub main / circuit wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 6 Sqmm and one run of 6 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and includingnon metallic PVC conduit of suitable size (external) with wall thickness not less than 1.8 mm, ISI marked concealedin wall includingaccessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge. NOTE: Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length. 68 Earthing complete with GI earth plate 600mmx600mmx6mm thick buried directly in ground vertically to a depth not less than 2.25 mtrs below ground level with top edge of earth plate to a depth not less than 1.5 mtrs below ground level, connected to and including GI wire 4 MM dia with GI protection pipe 15 mm dia light grade connected upto DBs by means ofbolts, nuts, check nuts and washers made of copper, galvanised iron medium grade 20 mm dia bore for watering and including funnel, wire mesh, RCC 1:2:4 cover slab 50 mm thick with re-inforcement of 8 mm TMT bars @ 100 mm C/C both directions and PCC chamber with PCC 1:3;6 type C2 including excavation and earth work, disposal of Surplus soil to a distance not exceeding 50 m, charcoal, lugs,common salt complete all as specified and as shown on plate No-3 of SSR part-I.