Tender For Construction Of Ctvs Transplant Ward In Aiims Raipur;  1 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)  2 Centering and shuttering including strutting, propping etc. and removal of form for  3 Lintels, beams, plinth beams, girders, bressumers and cantilevers  4 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.  5 Thermo-Mechanically Treated bars of grade Fe-500D or more.  6 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.  7 Half brick masonry with non modular fly ash bricks of class designation 10, conformingio IS :12894, in super structure above plinth and upto floor V level.  8 Cement mortar 1 : 3 (1 cement : 3 coarse sand)  9 Providing and fixing 15-17 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias, skirtings and similar locations of required size, approved shade, colour and texture laid with epoxy resin based adhesive, joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, cleaning, moulding and polishing to edges to give high gloss finish etc. complete at all levels: Granite stone slab colour black, Cherry/Ruby red and any size:  10 Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete.  11 40 mm  12 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.  13 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :  14 250x16 mm  15 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :  16 200x10 mm  17 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.  18 Twin rubber stopper  19 Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete.  20 Double strip (horizontal type)  21 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.  22 Providing and fixing to existing door frames.  23 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.  24 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.  25 100mm  26 Providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineerin- charge.(Payment of providing and fixing auto closing hinges shall be paid separately)  27 Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge  28 200 mm  29 Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approved make 500 mm long with screws etc. complete as per directions of Engineer- in-charge.  30 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.  31 Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).  32 Size of Tile 600x600 mm  33 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.  34 110 mm diameter  35 Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mmmade out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, lightfittings, fixtures, smoke detectors etc., wherever required.  36 Main ‘T’ runners to be suspended from ceilingusing G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dashfasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted withpolyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.  37 12 mm cement plaster of mix :  38 1:6 (1 cement: 6 fine sand)  39 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.  40 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.  41 Two coats  42 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge  43 In cement mortar  44 Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.  45 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.  46 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :  47 W.C. pan with ISI marked white solid plastic seat and lid  48 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:  49 White Vitreous China Angle back wash basin size 400 x 400 mm with single 15 mm C.P. brass pillar tap  50 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :  51 Size 600x450x200 mm  52 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.  53 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.  54 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.  55 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.  56 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints completeas per direction of Engineer in Charge.  57 50 mm nominal dia Pipes  58 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.  59 20 mm nominal dia Pipes  60 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :  61 25 to 40 mm nominal bore  62 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :  63 20 mm nominal bore  64 Providing and fixing uplasticised PVC connection pipe with brass unions :  65 45 cm length, 15 mm nominal bore  66 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.  67 15 mm nominal bore  68 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931  69 15mm nominal bore  70 Providing and fixing PTMT grating of approved quality and colour.  71 Circular type 100 mm nominal dia  72 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :  73 For fixed portion.Powder coated aluminium (minimum thickness of powder coating 50 micron)  74 For shutters of doors, windows & ventilators includingproviding and fixing hinges/ pivots and making provisionfor fixing of fittings wherever required including the costof EPDM rubber / neoprene gasket required (Fittingsshall be paid for separately)Powder coated aluminium (minimumthickness of powder coating 50 micron)  75 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin- charge.  76 Pre-laminated particle board with decorative laminationon both sides  77 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasketn etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):  78 With float glass panes of 5 mm thickness (weight notless than 12.50 kg/sqm)  79 Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.  80 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixedm with water proofing cement compound @ 0.126 kg/sqm. Thislayer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.  81 Providing and fixing concealed hinge of approved quality for 19-20mm thick door with stainless steel screws complete :  82 Providing and fixing in position Double bay stainless steel (304 grade) scrub station of size 1220x610x1500 mm with automatic sensor & foot operated tap with hot and cold water temperature controller valve and foot operated soap dispenser arrangement of approved make and quality as per the direction of engineer in charge.  83 Providing and fixing 44 mm thick HPL (Hinge Pressure Laminate ) Hermetic Hinge single Leaf Door for civil opening 1800(W)x2100 (H) with S.S. Ball bearing hinges , D Handles , both side key operation dead lock ,View window size 300x300 mm ,sealing gasket, Automatic Drop seal ,door seal and one door closer etc. all complete as per instructions of Engineer In charge.  84 Providing and fixing frosted film of make 3M/Avery/Oracal and of thickness not less than 1 mm over the glass of windows, glass partition etc including cutting of film in a certain design, shape all complete as per the instructions of Engineer In charge.  85 Providing and applying anti microbial epoxy PU flooring of thickness not less than 3 mm, in required colour, patterns etc. having anti skid properties,corners should be uniformly curved, final surface should be non corrosive to biological fluids, detergents etc. all complete as per the instructions of Engineer In charge. The execution of item shall involve activities of cleaning the surface, grinding of the cleaned surface by manual or mechanical means, applying PU flooring primer on the complete surface followed by screed activity to level the complete surface and then followed by applying PU Topcoat. The items to be used shall be of make BASF/ENDURA/MYK failing which the make approved by Engineer-in Charge shall be used. The work is to be executed and completed all as per manufacturers specification and as per direction of Engineer-in Charge.  86 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.  87 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.  88 Using M.S. angels 40x40x6 mm for diagonal braces  89 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.  90 In stringers, treads, landings etc. of stair cases, includinguse of chequered plate wherever required, all complete  91 Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge.  92 10 x 120 mm  93 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :  94 1:2:4 (1 cement : 2 coarse sand (zone-III) derived fromnatural sources : 4 graded stone aggregate 20 mmnominal size derived from natural sources)  95 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately.  96 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :  97 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture  98 Providing and fixing 50 mm thick galvanised Puf panel of make Jindal/Tata/JSW on the walls and roof (size, shape and pitch of corrugation as approved by Engineer-in-charge) . The sheet shall be fixed using self drilling /self tapping screws of required size with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces,including cutting to size and shape wherever required, Fixing operations of roof/wall panels shall be completed in all respect as per drawings and manufacturers specifications and under the overall direction of the Engineer-in-charge.Drawing and Layout of Puf Panel is to be submitted by the contractor for the approval of Engineer-in Charge. No separate amount is to be paid by the department to the contractor for drawing/layout  99 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit & accessories as required.  100 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire  101 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire  102 2 X 4 sq. mm + 1 X 4 sq. mm earth wire  103 4 X 4 sq. mm + 2 X 4 sq. mm earth wire  104 4 X 10 sq. mm + 2 X 6 sq. mm earth wire  105 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.  106 5/6 A switch  107 15/16 A switch  108 3 pin 5/6 A socket outlet  109 6 pin 15/16 A socket outlet  110 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.  111 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.  112 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.  113 1 or 2 Module (75mmX75mm)  114 3 Module (100mmX75mm)  115 4 Module (125mmX75mm)  116 6 Module (200mmX75mm)  117 8 Module  118 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.  119 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required  120 1 run of cable  121 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.  122 100 A,30KA,FPMCCB  123 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).  124 6 way (4 + 18), Double door  125 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.  126 Single pole  127 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.  128 63 A  129 Supplying and fixing TP&N MCB,440 volts, C curve, suitable for inductive load of following poles in the existing MCB DBcomplete with connections, testing and commissioning & accessories etc. as required.  130 63 A TP&N MCB  131 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required.  132 For 6 way, Double door TPN MCBDB  133 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.  134 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm).  135 Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as required.  136 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)  137 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.  138 Supplying and fixing TP&N MCB,440 volts, C curve, suitable for inductive load of following poles in the existing MCB DBcomplete with connections, testing and commissioning & accessories etc. as required.  139 40 A  140 Supply and laying of3.5*50 Sqmm 1.1 kV grade PVC Sheathed XLPE insulated aluminium armoured cable.  141 Supply and Installation of Exhaust fan suitable for single phase, 230 volts, 50 Hz, AC supply having RPM 1100or better , 300 mm sweep, power input = 35W or less, Air delievery ≥ 700 CFM complete with motor, louvers/ shutters etc. as required in the existing window, includes dismembering of window glass, providing and fixing ACP panel (6mm thickness Aluminium composite panel) framing in place of glass, connection, testing, commissioning etc. as required.  142 Supplying, installation, Testing & Commissioning of LED Recessed /surface Down lighter (Round / square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C)  143 18 watt  144 Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin),CM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).  145 36 watt  146 Supplying and Installation of clean room recess mounted 600X600 mm, 30-34 watt LED luminaries with lumen efficiancy of >100 lm/W, dimming option, highly specular anodized aluminum reflectors, optical antiglare system, high effiency polycarbonate diffuser with EMC/EMI compliant electronic driver having PF>0.9, THD < 10%, & minimum of 3kV surge/burst protection, complete with 50000 hrs burning for lifetime with supporting data sheet LM-79 & LM-80. Luminaries cover should be made of highly resistant, disinfectant proof laminated, safety glass/acrylic with stylish fine-grained surface. The reflectors should be of high quality, cleanable and non-deteriorating. The Recess frames should be gas tight. The white luminaries body should be made of sheet steel, perfectly powder coated, supplied ready for connection optionally for individual or series circuit with digital electronic control gear in multilamp technology. The Light fitting should be flush with the ceiling and should be removable from top or bottom. Optional pre-set color temperatures or adjust to any CCT in the Productivity Range 3000 K - 5700 K, Dimming Range 10%-100%The LED used in the luminaire shall be only Lumileds, Nichia, Cree, osram & LGIT and hanging with necessary chain etc as required.  147 Supply and Installation of 10 litre capacity Water Geysers in required locationequivalent to Jaquar model- EPM-WHT-V010* 10 liter capacity* Temperature Range:- 25-70ºC or better* Wattage:- 2KW or less* 5 star rating* suitable for single phase, 230 volts, 50 Hz, AC supply.  148 Supplying and Installation of 60 mm thick hermetically sealed single sliding door of ( 2.1 m (H) x 1.5m (W))/(2.1 m (H) x 1.8m (W)). The controller should be capable of being operated by elbow switches/ foot switches as well as touch less sensor. The track should be of Stainless steel/ Aluminum and the running surface for the top rollers should be suitably angled to reduce resistance to movement. The door material should be of HPL colour should match the interior and care should be taken to make the leaf strong and light weight.The door leaf should be hung by means of hard plastic rollers of high quality with double bearing at the top. Rollers should be provided under the stainless steel/ Aluminum track to enable smooth and noiseless movement. Opening and closing of the door should be microprocessor controlled electromechanical movement. One should be able to open and close the door effortlessly in case of failure of automatic mechanism. Door opening handle should be of SS (gloss finish), i/c high quality cylindrical lock. Door leaf should have high quality synthetic rubber gasket with long life to ensure hermetic sealing, Air tightness 99.99% at a pressure of 100KPa. The finished floor on either side of the door should be perfectly level (maximum permissible difference +1mm). The overall thickness of the finished door should be of 60mm. The inner part of the door should be filled with CFC free polyurethane foam. (Sealed airtight to prevent further ingress of any microbial organism). The door and controls should comply with IEE regulation. All motors used should be DC brushless motors with essential isolation from mains. All motors used should be DC brushless motors with essentíal isolation from mains. Door should be with vision window 300 mm x 300 mm with double glazed panels and hermetically sealed motorized roller blind inside. The starting time after receiving the signal shauld be adjustable between 0.5 to 20 seconds. The complete door assembly should be BIS/ European CE marked/ US FDA approved. Test certificate for hermetically sealed door frame (factory test certificate) should be enclosed with the pre dispatch documents.Hermatically Sealed HPL finish DOOR - Automatic with automation,Supply, Installation, Testing of automatic sliding hermatically OT door size of with Double sided wall frame with HPL Plank 400mm.1- Door Profiles- Aluminium Alloy, Grade 6063, Temper T6. Natural Anodized 20 μm.2-PIR. Dimensional stability at +100°C & -25°C (2%max).Density 41Kg/M3 with max deviation of 2kg/m3 as perDIN53420.3- Door Skin- HPL (4mm) both side of door4- Sealing Gasket (Sides and Top)- Replaceable Bulb and Lip design EPDM gasket.5- Sealing Gasket(Bottom)- .Replaceable Special lower sealing EPDM gasket.6-. Vision Panel- Double Glazed IG unit with 5mm tempered glass on both sides. Size = 300 mm x 300 mm x 60mm.7-Lever Handle- Solid AISI 304 Grade Stainless Steel with rubber spring system.8- Rail System- 6mm deep indentations with ‘down and in’ movement at the angle of 45⁰.9- Rollers- Special Grade Self-lubricating PA Bearings: 2X per roller.10-Wall Frame- Aluminium Alloy, Grade 6063, Temper T6 Natural Anodized 20 μm.11- Planks- HPL Planks finished with compact laminates are used to cover the door opening.12- Noise Insulation-28 dB.13- Air Permeability- Air Leakage at ± 100 Pa (pressure difference) = 0.07 m³/h.m. 1-Microprocessor Based controller. (230 Vac, 750 W (max),2- motor, IP65 protection Class, 20 Nm, 3Øx230V. (CE Marked).3- If an obstruction is present and prevents the door from closing, the intelligent automation sense with self reversal function thus eliminatingthe need for an ugly safety strip.4- Additional safety is provided by means of a photo cell fitted across the door opening.5- Variable options for the opening and closing speeds, time delay closing and part opening for pedestrian use and are easy to adjust.6- A self diagnostic coded system makes fault finding simple, reducing expensive down time.7- Magic (Hand) Switch- The spread of infection is controlled by automating the doors with touch less sensors allowing hands free operation.8- Foot switch or Elbow Switch- AISI 304 grade Stainless Steel Foot Switches with high quality inductive sensors.Control: Microprocessor-controlled with Deceleration Measurement System sliding door drive.Power supply: 230 Vac +10% / -15%. Frequency: 47-63Hz . Power Consumption -Maximum : 750 W.Drive :STG motor. Nominal Motor power:90 W, High Torque Motor -20Nm.Microprocessor controlled motor driver. Max. door weight : 350 Kg.Adjustable Speed Control level: 1-9 . Slow speed (V slow) :20(Threshold speed) - 120 mm. / sec.Starting speed (V start) :20(Threshold spped) - 220 mm. / sec. Opening speed (V open) :Threshold speed to 800 mm. / sec. Closing speed (Vclose):Threshold speed to 400 mm. / sec.Pedestrian opening (Half Opening width) :10% - 99% of the available door opening.  149 Supply ,Installation,Testing & Commissioning of factory built cabinet type unit withAl anodised thermal break frame structure injected with minimum 45+-5 mm thick PUFinsulation, GIPanelshallbepowdercoatedfrombothinnerandouterside,evaporationDxcoil expansion valve and corded remote ,Fan section with double width double inlet (DIDW backwards curved) centrifugal fan with Variable speed Fan Motor with VFD, prefilter section with EU3 / G4 class filters & EU-7 Filter(As per Approval of Engineer Incharge ) Dx coil.units shall be with a remote controller as per site requirement. Rating for the AHUs shall be as under - Motor selection (IE-3) to suit the below capacity AHU ratings. AHU shall be mounted on floor/Ceiling Mounted with vibration isolatorsUnit shall be with factory fitted inlet/outlet aluminium Aerofoil dampers. ,Temperature controller ,Door open switch ,pressure drop across filters ,Fan motor over load protector ,Suitable UV System Chamber complete with cable /wiring etc. will be part of this AHU Unit. AHUShouldhave1setofSpareFiltersapartfromCommissioningfiltersfixedinAHU. SuitableCommunication cable from indoor to outdoor is in the scope of agency .Double Skin Heater Bank Chamber comprising of SS 304 spiral strip heaters fitted with Porcelene blocks, Safety air stat & access door for heater rating , UVGI Lamp etc. As per per approved design from Engineer Incharge. AHU connection Kit with Control box (expansion valve ), Control Box,Nitrogen Testing ,Vaccuming , Green Refrigerant Top up .It should be equiped with Controler to control humidity up to 55 % (+-5%).AHU Machine should be Equipped withmotorised Fire Dampers .F.M./S.A Fan 4000 CFM /18 TR(24 HP) X 2 Numbers Coils / 6 ROW coil Full Copper , with two Stage Filter level 10 micron + 5 Micron,ESP-150 MM in WC. Design parameter- Temp.-21+-3 Degree Centigrade , Relative Humidity -55+-5%  150 Supply, Installation, Testing & Commissioning of 22 HP modular type variable refrigerant flow / Variable regrigerant Volume air cooled outdoor units suitable for cooling and heating having all hermatically sealed inverter type scroll compressor, minimum two compressor for above 14 HP modules, microprocessor based controller,top discharge type condensing units, with R410 A refrigerant, Vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI conditions and work even at 50 degree Celcius ambient temperature without tripping. The unit shall be suitable to work on 400+/-10%, 3phase , 50 Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required with suitable communication cable. The COP at AHRI Conditions shall not be less than 3.1 and IEER not less than 6.5.  151 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :  152 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm  153 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm  154 Supplying and installing 225 mm width X 50 mm depth X 1.6 mm thickness size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.  155 Supply, installation, balancing and commissioning of Site fabricated Aluminium 0.80 mm rectangular/Circularducting as requiredwith supports as per IS 655-2006 complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following gauges (Galvanizing shall be with zinc nominal 120 gm/sqmtr) includes cutting/ dismanteling of wall (if required) and make good the same.Note: Fabrication and jointing of duct shall be as per IS standard and hanging shall be as per SMACNA.  156 Thickness 0.80 mm sheet  157 Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.  158 Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.  159 Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.  160 Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.  161 Fire Damper  162 Actuator  163 Supply and fixing of acoustic lining of AHU wall and ceiling with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to wall and ceiling with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications.  164 Supplying and fixing of 19 mm thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class O) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.  165 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge for Drainage.  166 32 mm nominal dia.  167 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit,fitting as required.  168 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire  169 Supply ,Fixing and erection of Duct rexin Fire Retardent Canvass Connections with Vibration & Isolation Pad complete as required .  170 Supplying and fixing of MS of (40X40X5)mm stand for condensing (Outdoor) with epoxy painting, unit Size - 1040 mm(L)*440mm(W)*300(H)} .  171 8 SWG (Copper ) Earthing Cable Supply & Fixing complete as required .  172 Supply and fixing of 10 mm Open cellacoustic insulation of supply air duct and plenum with fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per direction of Engineer Incharge AIIMS Raipur.  173 Supplying, fixing, testing and commissioning of Hepa Filter of required Specification withincluding making arrangement for fixing complete as required and as per direction of Engineer-in-charge.Class-14,Efficiency -99.97  174 Supplying, fixing, testing and commissioning of 1 Tile Membrane Surgeon Control Panel of following Specification including making arrangement for fixing with necessary acessaries ,Cable etc. complete as required and as per direction of Engineer-in-charge.  175 Supplying, fixing, testing and commissioningofmotorised damper as required Specification withnecessaryarrangementas per direction of Engineer-in-charge.  176 Supply and fixing ofinsulation work with 6 mm nitrile rubber on existing CPVC drain pipe(32 MM) properly as required.  177 Supply, Installation and Testing of G I Sheet with Galvanized Coating cable tray cover for 225 mm powder coating M.S. cable trays it is highly durable and robust , corrosion and can sustain high load andincluding bolts & nutsall accessories as per specifications etc. as required.  178 Supplying, installation, testing and commissioning of M.V/LT. cubical type totally enclosed dust and vermin proof Floor/Wall mounted Sub Main Distribution Boards suitable for use on 430 V 3 phase 4 wire 50 Hz AC supply, having compartmentalized construction for different incoming/outgoing MCCBs from Approved Make, and separate bus bar & cable alleys , fabricated from min 1.6mm thick CRCA sheet steel of uniform width complete with copper bus bars , MV/LT danger notice plate, Digital type ammeter with Ammeter selector switch , voltmeter with Voltmeter selector switch , LED indicating lamps, cast resin CTs , Confirms to IEC-61439-2, IP-43, Interconnection with suitable capacity copper strips / rods, connection of incoming and outgoing cables with thimbles , smoke/Siemens grey colour stove enamelled painted and having following incoming and outgoing switchgears, 2 earth bolt, removable cable gland plate with spare suitable hole, wall/floor mounted, lockable using hollow standard LT Panel lock key complete as per site required or as approved by Engineer In-charge. A. INCOMER 01 nos. 250amps 35kA TPNL MCCB from Approved Make Thermo-magnetic release type with rotary handle. 01 nos. Digital type single function volt meter to show 0-500V voltage with phase selector switch01 nos. Digital type single function ameter to show amperage with phase selector switch 03 Nos Energy Meter 03 Nos CTs 125/5 ratio 03 LED Indication Light with toggle switches B. OUTGOING 08nos. 40A TPNL MCCB (25 KA) Thermo-magnetic release type.  179 Dismentlingwork of Existing installed duct, FCU, HVAC Pipelines, Starter Panelincluding Welding, Cutting as required as per direction of Engineer Incharge AIIMS Raipur.  180 Supplying, installation, testing & commissioning of smokedetector with builtin LED and mounting base complete with all connections etc. as required.  181 Supplying,installation,testing&commissioningofmanualcallboxesofMS constructionin surface/recesswithstainlesssteelchain&hammerassembly complete with glass and push button etc. as required.  182 Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required.  183 Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.  184 Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered along with battery arrangement for power backup complete with all connections, interconnections as required.  185 4 Zone  186 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.  187 Supply and fixing of 4 kg clean agent (HCFC) portable fire extinguisher having pressure guage indicator and arrangement for wall hangingand with warranty for 5 years on complete product.  188 Providing and fixing you are here sign board near entrance and fire reflective sign board, reflective stickers signage for indication at fire doors, fire extinguisher, fire exit with suitable size as per requirement and as per instruction from Engineer In-charge.