| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 17-11-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 24-11-2025 |
| Sl. No. | Item Description |
| 1 | Demolition of plain cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 2 | Demolition oftiles of any description or thickness in floors, aprons etc laid, bedded and pointed in mortar complete all as specified and directed. |
| 3 | M&L for second class hardwood as in scantlings clean sawn timberfixed with and including dismantling of old timber scantlings 40 sqcm and over in section, in unframed work in any position complete all as specified and as directed. |
| 4 | M & L for plain fillets, square, rectangular or triangular in section clean sawn, secured with nails made out of 2nd class hard wood exc 13and n.exc 25 sqcm complete all as specified and as directed. |
| 5 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quions, arches, pillars ,etc complete all as specified and as directed. |
| 6 | M&L for brick work with sub class \"B\" bricks (using old size burnt bricks) straight or curved on plan exc 6m mean radius in half brick thick wall built in cement mortar (1:4) complete all as specified and as directed. |
| 7 | S&FPre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed. |
| 8 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 9 | S&FPre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified with and including dismantling of old Plain or corrugated steel sheeting, any gauge, thickness, including Nainital orsimilarpattern roof coverings complete all as specified and as directed. |
| 10 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws asspecified with and including dismantling of old Plain or corrugated steel sheeting, any gauge, thickness, including Nainital orsimilarpattern roof coverings complete all as specified and as directed. |
| 11 | M&L for 15mm thick plastering in CM (1:4) on one side of lathing in two separate layers without using extra cement but using water proofing compound @ 3% by wt of cement for finished even and smooth including demolition of reed, lathing single or double, including battens and plaster or chicken wire lathing with and including GI wire netting 0.71 mm dia and 12 mm mesh lathing in to reed in walls incl all laps cutting and waste complete all as specified and as directed. |
| 12 | M&L for rendering 12 mm thick in CM (1:6) on other side of lathing finished even and smooth without using extra cement complete all as specified and as directed. |
| 13 | S&F Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengthsi.e. within 20mm of the length indicated) confirming Fe 410 -W (Gde- E- 250) quality- A complete all as specified and as directed. |
| 14 | S & F Plates (plain or chequered) channels,squarecutor notched (ordinaryand countersunk) forming holes, without any attachment conforming to Fe 410 -W (Gde- E- 250) quality- A complete all as specified and as directed. |
| 15 | M&L for Non Skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm,in floors laid over and including 15mm thick screed bed or bedding layer of cement mortar 1:6 for laying floor finishes, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles including demolition oftiles of any description or thickness in floors, aprons etc laid, bedded and pointed in mortar complete all as specified and as directed. |
| 16 | All as per Item No 15.00 (here-in-before) but on vertical surfaces such as skirting , dado, risers to stepsover and including 10 mm thick backing coat in Cement Mortar 1:4. |
| 17 | M&L for Non Skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm,in floors laid over and including 15mm thick screed bed or bedding layer of cement mortar 1:6 for laying floor finishes, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and as directed. |
| 18 | All as per Item No 17.00 (here-in-before) but on vertical surfaces such as skirting , dado, risers to stepsover and including 10 mm thick backing coat in Cement Mortar 1:4. |
| 19 | M&L for Non Skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm,in floors laid over and including 15mm thick screed bed or bedding layer of mortar for laying floor finishes in Cement Mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles including demolition oftiles of any description or thickness in floors, aprons etc laid, bedded and pointed in mortar complete all as specified and as directed. |
| 20 | M&L for Glazed ceramic coloured tiles in vertical surface 300 mm X 200 mm / 350 x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tileover and including baking coat of 10 mm thick in Cement Mortar (1:4),including demolition oftiles of any description or thickness in floors, aprons etc laid, bedded and pointed in mortar complete all as specified and as directed. |
| 21 | M & L for PCC 25 mm thick type B-0, (1:2:4) (using 12.5 mm graded stone aggregate)as in levelling course of floor complete all as specified and as directed. |
| 22 | M&L for 75 mm thick PCC (1:3:6) type C-2 , (using 40 mm graded stone aggregate) as in plinth protection laid to slope of 1:12, finished fair and even without using extra cement with and including all necessary formwork to divide that area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 10 mm wide joints throughout thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and as directed. |
| 23 | S & F for4 mm thick of size 600x600mmHSPC (high pressure Steam Cured) non asbestos fibre cement reinforced multipurpose board, pre-painted self embossed, textured designer boardE-Board Classic fixed or laid/inserted to timber/ GI frame work with screws to be fixed in ceiling flat or sloping and Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre both ways, size of grid 605 x 605mm fixed with steel dash fasteners or from purlin from the roof with alignment clip including providing provisions for light fixtures of any sizeincluding dismantling of old unsv ceiling boards (fibre, pulp, insulation, etc.) any thickness including cover fillets of any description and at any location complete all as specified and as directed. |
| 24 | Taking down chowkhat or frames not exc 1.5 Sqm each (without taking off shutter from the frame) complete all as specified and as directed. |
| 25 | Taking down chowkhat or frames exc 1.5 Sqm but not exc 4 Sqm each (without taking off shutter from the frame) complete all as specified and as directed. |
| 26 | M&L for 2nd class hard wood plain solid straight chowkats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pined joints complete all as specified and directed. |
| 27 | S&F 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed. |
| 28 | M&L for 30mm thick 2nd class hard woodGlazed and skelton window and ventilator shutter, open rebated and prepared to receive glass, gauge etc. divided into squares with plain chamfered or rounded, mitred and rebated sash bars edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I Section-8 clause 8.24(b) complete all as specified. |
| 29 | S&F in repairsgalvanised mild steel wire cloth, 0.56 nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed. |
| 30 | S&F powder coatedaluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing complete all as specified and as directed. |
| 31 | S & F for Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws complete all as specified and as directed. |
| 32 | S & F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 33 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, as per specification complete all as specified and as directed. |
| 34 | S&F Factory made solid panel pvc doorshutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined to-gether with solvent cement as per specification complete all as specified and as directed. |
| 35 | S&F butt hinges medium grade cold rolled mild steel and fixed size of hinges 100 mm long size complete all as specified and as directed. |
| 36 | S&F Aluminium anodised barrel tower bolt of extruded section and fixed 100 mm long complete all as specified and as directed. |
| 37 | S&F Aluminium handle cast type anodised 150 mm long complete all as specified and as directed. |
| 38 | S&F Aluminium alloy anodised sliding door bolt with hasp and staple (bolt type fixing clips of sheet cast or extruxded section(300 mm long) complete all as specified and as directed. |
| 39 | S&F in repair 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed. |
| 40 | S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc .50 sqm in each panels complete all as specified and as directed. |
| 41 | Taking down cement plaster on brick walls including raking out joints hacking for key, scrubbing down with water etc |
| 42 | M&L for Rendering 15 mm thik in CM (1:6) on fair face of brick-work or concrete surface to be finished even and smooth without using extra cement complete all as specified and as directed. |
| 43 | M&L for rendering 15mm thick in cement mortar (1:4) on fair faces of brick or concrete work even and smooth without using extra cement complete all as specified and directed. |
| 44 | M&L for applying two coats of oil bound distemper over a coat of primer over a coat of 3mm thick wall care putty on new plastered surfaces of walls including preparation of newsurface complete all as specified and as directed. |
| 45 | M&L for preparation of new plastered surfaces and applying two coats ofcement base paint over a coat of primer of approved shade on walls complete all as specified and as directed. |
| 46 | M&L for preparation of old painted wood and wood based surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint in any tint complete all as specified and as directed. |
| 47 | M&L for preparation of new untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 48 | M&L for preparation of newsurfaces of steel and iron work of any description over 10 cm width or girth not otherwise described andapplying two coats of synthetic enamel paint over a coat of red oxide primer on new surfaces in any tint complete all as specified. |
| 49 | M&L for preparation of old surfaces of steel and iron work of any description over 10 cm width or girth not otherwise described andapplying one coat of synthetic enamel paintin any tint complete all as specified. |
| 50 | S&F in repairs tubes medium grade, galvanised wih all fittings and fixed complete to walls and ceiling or laid on floors etc, 15 mm bore complete all as specified and as directed. |
| 51 | S&F in repairs tubes medium grade, galvanised wih all fittings and fixed complete to walls and ceiling or laid on floors etc, 20 mm bore complete all as specified and as directed. |
| 52 | S&F tubes of medium grade, galvanised wih all fittings and fixed complete to walls and ceiling or laid on floors etc, 20 mm bore complete all as specified and as directed. |
| 53 | S&F PVC valveless, syphonic action type, flushing cistern, low level,white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed. |
| 54 | S&FVitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) and including EWC Seat cover complete all as specified and as directed. |
| 55 | Supply only flush pipe of polyethylene of low or high density of PVC 32mm dia for low level cistern complete all as specified and as directed. |
| 56 | S&F in repairs CP Health Faucet with 1 mtr metalic Expandable tube & hook complete all as specified and as directed. |
| 57 | S& Fcast iron P or S trap of 100mm diacomplete all as specified and as directed. |
| 58 | M & L for roof treatment of roof of bldg/stair Case/tank Portion including the following :-(i) Roughening surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.(ii) M & L for 25 mm thick Cement concrete type B-0, 1:2:4 (12.5 mm graded aggregate) as in top of roof.(iii) Screed bed or bedding layer 15mm thick layer of cement mortar (1:4)and surface finished evern and smooth without using extra cement.(iv) Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sqm including cleaning surfaces.(v)APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyester non woven fabric laid on primed surface by forced application.(vi)Applying a coat of solar reflective bituminous aluminium paint @ 0.11Kg/Sqm over mineral surface. |
| 59 | M&L for brick work with sub class B bricks(using old size burnt bricks) straight or curved on plan exc 6 m mean radius in CM (1:4) complete all as specified and as directed. |
| 60 | M&L for complete removal of exisitng treatment of old decorated surfaces ofwall applying two coats of oil emulsion distemper over a coat of primer over coat of wall care putty(2mm thick in two layers) for obtained smoothness of wall surfaces complete all as specified and directed. |
| 61 | M&L for 5mm thick cement plastering in cement mortar (1:3) over ceiling surfacesfinished fair and even,complete all as specified and as directed. |
| 62 | M&L for complete removal of existing treatment on walls and preparation of old surfaces of wall including scrapping down, smoke soot, efflorescent salts trading oil and greasy spots etc applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed. |
| 63 | S&F in repairs for 15mm dia of pipe bib tap cast copper alloy, fancy type, chromium plated with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule and fixed as approved by complete all as specified and as directed. |
| 64 | S&F in repairs Stainless steel soap dish white of size 160 x 160 x 90 mm as approved fixed with brass screws or embedded in wall completeall as specified and as directed. |
| 65 | S&F in repairs 600mm long tubular tower rail brass chromium plated 20mm dia, D type ,fixedwith two plugs (Gutties) of 2nd class hard wood embeded in cement mortor 1:3 with MS screws completeall as specified and as directed. |
| 66 | S& F in repairs600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers completeall as specified and as directed. |
| 67 | S&F in repairs CP toilet paper holdercompleteall as specified and as directed. |
| 68 | S&F in repairs corner glass shelf assembly 250mm radius made of 6mm thick craaylic glass, with CP railing, fixed with suitable rowal plug & screws complete all as specified and as directed. |
| 69 | S&F in repairs vitreous china wash basin, size 550 x 400mm white including brackets, and waste coupling & pipe of 32mm dia, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other and fixed complete all as specified and as directed. |
| 70 | S&F of PVC (SWR) 110 mm dia pipe complete all as specified and as directed. |
| 71 | S & FPVC (SWR) Bend with any radius of 110 mm dia complete all as specified and as directed. |
| 72 | S&F of PVC (SWR) 75 mm dia pipe complete all as specified and as directed. |
| 73 | S & FPVC (SWR) Bend with access door any radious of 75 mm dia complete all as specified and as directed. |
| 74 | M&L for cement concrete type C-2 (1:2:4) (using 20 mm graded stone agg) as in surface channels and drains complete all as specified and as directed. |
| 75 | M&L for chequered cement concrete tiles of size not less than 300x300x25mm thick laid over and including 15mm thick screed bedfor laying floor finishes in cement mortar (1:6) etc, set, jointed and pointed in neat cement slurry with grey cement and pigments complete all as specified and directed. |
| 76 | M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms mouldscomplete all as specified and as directed. |
| 77 | M&L for vitreous china squatting pan, Orissa, pattern size 580 x 440 mm white with integral foot rests(excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti-syphonage pipe etc complete including making good to floor complete all as per specified and as directed. |
| 78 | S & F in repairs vitreous china bowl urinal flat back size of 465x355x265 mm white (minimum) with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as per specified and as directed. |
| 79 | S&Fsteelworkintubulartrusses, post, purlinsincludingspecialshapedwasheretc.CompleteusingERWorinductionbuttweldedtubesconformingtoIS1161-1979gradest-240complete all as specified and as directed. |
| 80 | M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to GDE Fe 410-W(Gde-E-250) quality-A complete all as specified and as directed. |
| 81 | S&F in repairsfor Draperly rod /Harrison rails of CP of 20mm dia with fixing brackets , stops, rollers and ringscomplete all as specified and as directed. |
| 82 | M&L for 35 mm thick 2nd class hardwood plain framed Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated ,supplied and fitted to chowkats complete all as specified and as directed. |
| 83 | M & L rendering 10 mm thick in cement mortar (1:6) on fair faces of brick or concrete work even and smooth without using extra cement complete all as specified and as directed. |
| 84 | S&F5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification complete all as specified and as directed. |
| 85 | S&F Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications complete all as specified and as directed. |
| 86 | Supply only Integralwater proofing compound complete all as specified and as directed. |
| 87 | M&L for 100 mm thick cement concrete (1:3:6) type C-1 (using 20 mm graded crushed stone) as in hardstanding / pathlaid in alternate bays ( n exc. 4 Sqm each) and finished even and smoothwithout using extra cementcomplete all as specified and directed |
| 88 | M&L for Non Skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm,in floors laid over and including 15mm thick screed bedin CM (1:6) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and as directed. |
| 89 | Material and labour for (concelaed Type) point wiring in repairs including necessary chases cutting of wall for one light/fan/call bell point with 1.5 sqmmPVC insulated (FR-LSH) PVC sheathed multistranded copper conductor cable 1100 volts gradecontrolled by one way switchincluding 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC conduit with all accessoriesand sunk GI box for mounting of fittings like switch, socket and fan regulator etc and making good the distrubed surfaces as per the existing complete all as specified and as directed by the Engr-in-Charge |
| 90 | Onelight pointcontrolled by one, one way switch . |
| 91 | One Ceiling fan/ exhaust fan point controlled by one, one wayswitch. |
| 92 | One 3 pin socket outlet 5 Amps on the same board with other switches. |
| 93 | One 3 pin socket outlet 5 Amps on the Independent board. |
| 94 | One bell pointcontrolled by one, one way switch . |
| 95 | All as per item No- 89.00 here-in-before but with 2.5 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor connected to common earth dolly complete all as specified and as directed. |
| 96 | M&L for Point wiring in repairs complete with two runs of 1.5 sqmm single core PVC insulated FR-LSH cable1100 volts grade with multi-stranded copper conductors, drawn throughand including PVC double locked Casing & caping/PVC Conduit pipe medium grade including provision of 1.5 sqmm, FR-LSH, PVC insulated copper cable as earth continuity conductor connected to common earth dolly, including PVC rectagular box for mounting switches / sockets / regulators etc.of suitable size as required at site complete all as specified and as directed. |
| 97 | Onelight controlled by one, one way switch. |
| 98 | One Ceiling fan point controlled by one, one wayswitch. |
| 99 | One 3 pin socket outlet 5 Amps on the same board with other switches. |
| 100 | One 3 pin socket outlet 5 Amps on the Independent board. |
| 101 | All as per item No- 91.00 here-in-before but with 2.5 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor connected to common earth dolly complete all as specified and as directed. |
| 102 | S&F Switch Piano, flush type single pole, one way 5 Amps complete all as specified and as directed. |
| 103 | S&F Socket outlet, 2 in 1, 5 pin 5A flush type complete all as specified and as directed. |
| 104 | S&F Switch Socket combination, 2 in 1, 5 pin 6A flush type complete all as specified and as directed. |
| 105 | S&F Switch Socket combination, 2 in 1, 5 pin 6A/16A flush type complete all as specified and as directed. |
| 106 | S&F bell push switch 5 amps piano type flush type complete all as specified and as directed. |
| 107 | S&F Bell AC 230 volts musical type complete all as specified and as directed. |
| 108 | S&F stepped type electronic fan regulator 100 Watt socket size flush type on the existing phenolic laminated sheet complete all as specified and as directed. |
| 109 | S&F ceiling rose 3 terminal PVC/Polycarbonate isolated body with PVC round/squareblock complete all as specified and as directed. |
| 110 | M&L for sub main wiring Casing capingtwo run 4.0 Sq mm and one run of 4.0 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn throughand includingcasing caping complete all as specified and as directed. NOTE:- Two runs of 4.0 Sq mm +one run of 4.0 Sq mm and one run of PVC conduit pipe and its accessories of suitable size shall be measured as one unit length complete all as specified and as directed |
| 111 | M&L for sub main wiring in repairs with two runs of 4.0 Sq mm and one run of 4.0 Sq mm for earth wire with multi standard copper conductors FRLSH quality, 1100 volts grade, drawn throughand including non metalic rigid PVC conduit with all conduit accessories (including concealing and making good to the disturbed surfaces of walls, ceiling,floors etc. including making good the disturbed surfaces and paint touch up to match with the existing surface) complete all as specified and as directed. NOTE:- Two runs of 4.0 Sq mm + one run of 4.0 Sq mm and one run of PVC Conduit and its accessories of suitable size shall be measured as one unit length. |
| 112 | S&F LED light fitting 1 x 20 W (4 FT), wall /surface mounted, integrated type with all accessories internally prewired and including connecting up with and including twin/three core twisted flexible copper conductor cable of suitable size in & incl flexible hose from ceiling rose to fitting complete all as specified and as directed.WH/Bajaj/Philips |
| 113 | S&F LED light fitting 1 x 10 W (2 FT), wall /surface mounted, integrated type with all accessories internally prewired and including connecting up with and including twin/three core twisted flexible copper conductor cable of suitable size in & incl flexible hose from ceiling rose to fitting complete all as specified and as directed. |
| 114 | S&F in repairs/replacement for decorative wall mounted light fitting made up of polycarbonate including 9 watt LED lampwith B-22 basecomplete all as specified and directed. |
| 115 | S&F Bed side light 3Watt LED light reading in bed just got easier with this colletion of adjustable LED bedside lights complete all as specified and as directed. |
| 116 | S&F in repairs Bldg Security LED 1x25W light fitting, drawn through including GI bracket of 25mm borelight grade bent to shape and fixed on wall with metal fastners 2 Nos 10mm dia incl drilling holesas required and connecting upwith flexible copper cable of size 0.75 Sq mm 3 core from ceiling rose to the light fitting complete all as specified and directed |
| 117 | Taking down carefully air curtain from existing location and keeping in safe custody, and refixing and providing the connection as per existing after the work completed complete all as specified and directed by Eng-in-charge.Note:-The nut , bolts, washers etc are deemed to be included in quoted rates. |
| 118 | Taking down and keeping in safe custody and refixing of Window/SplitAir conditioner units indoor/outdoor complete with cordless remote control and with inbuilt air ioniser and Plasma filter for better indoor air quality with twin rotary compresser three phase units 415 volts 50 Hz of capacity 1.5 TR With eco friendly refrigerent.Note :-(i) Cutting holes in walls/ Windowof any thickness for installation of AC etc, connection and making good the disturbed surface to match with the existing surface after work shall be done and rate is included in above rate .(iii) Electrical cable required to connect outdoor unit with indoor unit and indoor unit to voltage stabilizer includedin above rate.(ii)copper piping/ drain piping includedin above rate. |
| 119 | S&F in repairs VTPN DPX 4 way,double door 415 Volts, 50 Hz, IP 43 IK 09 sheet steel, powder painted, with02 neutral link & 02 earth bar and cable ties for cable managementsuitablefor fixing ofMCCB asincomer and MCB SP/TP as outgoing MCB DBsand making good the disturbed surfaces to match with existing specification , complete all as specified and as directed.Note : MCBs will be measured and paid separately. |
| 120 | S&F in repairs MCCB 4 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 16 KAcomplete all as specified and as directed. |
| 121 | S&F in repairs LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling and connecting up with driver, three core flexible copper conductor of suitable sizecomplete all as specified and as directed. |
| 122 | S&F in repairs MCB Distribution board double door type SPN 12 way, sheet steel, powder painted, with bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacitymaking good the disturbed surfaces to match with existing specification , complete all as specified and as directed.Note : MCBs will be measured and paid separately. |
| 123 | S&F in repairs MCB Distribution board double door type SPN 8 way, sheet steel, powder painted, with bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity and making good the disturbed surfaces to match with existing specification , complete all as specified and as directed.Note : MCBs will be measured and paid separately. |
| 124 | S&F sheet metal enclosure with socket plug top and MCBs , single poleand neutral encloser with two pin and earth plug and socket complete one single pole MCB SP 20 Amps complete all as specified and as directed. |
| 125 | S&F in repairs MCB SPN 32 Amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning MCB DBcomplete all as specified and as directed. |
| 126 | S&F in repairs MCB SPN 40-63 Amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning MCB DBcomplete all as specified and as directed |
| 127 | S&F in repairs MCB SP 6 to 32 Amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning MCB DB complete all as specified and as directed. |
| 128 | S&F in repairs exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250m complete all as specified and as directed. Note : Old Exhaust Fan shall be deposited to EM store yard. |
| 129 | S&F in repairs ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed. Note : Old ceiling fan shall be deposited to EM store yard. |
| 130 | M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of16 sq mm, 4 core including taking out old unsv cable complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items. |
| 131 | M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of16 sq mm, 2 core including taking out old unsv cable complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items. |
| 132 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft/ loose soil complete all as specified ans as directed. |
| 133 | Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all complete all as specified ans as directed. |
| 134 | Removing of excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all complete all as specified ans as directed. |
| 135 | M&L for spread fine river sand in trenches as in protection to UG cable complete all as specified ans as directed. NOTE: Punned down thickness shall be measured and paid. |
| 136 | Supply & laying tubes \" light grade\" galvanised, with all fittings, fixed complete to walls, poles, ceilings or laid in floors/ trenches/ road crossing for protection of cables of size 40 mm dia bore including taking out corroded GI tubing complete all as specified and as directed. |
| 137 | M&L for laying brick sub class \"B\" old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directed |
| 138 | Material & labour for cutting/ digging of existing Hard surface of cement concreet/Bituminous road of size not less than 45 cm in width and 20 cm deep for laying of LT cable& making good to the disturbed surfaces by providing PCC or same material after laying of pipe line and returning filling of soil complete all as specified and as directed. |
| 139 | M&L for earthing complete with galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4 mm dia as earth lead connectd by means of bolts, nuts, washers and check nuts all as shown in electrical plate No 3 of MES SSR Part-I, including testing on completion complete all as specified and as directed. NOTE:- (i)The unit rate shall also included for earth work in hard/ dense soil, PCC (1:3:6) type C1 chamber, CI cover 10 m thick, funnel with GI watering pipe 20mm dia Medium grade, GI protection pipe light grade 15mm dia and wire mesh complete in addition to item No 1 (a) to (e) of preamble (notes) under sub heading earthing, specified on Sl Page No 389 of MES SSRPart-II. (ii)Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. |