| 1 | Excavation for foundation in earth, soils of all types, sand, Gravel and soft murum, including removing the excavated material upto a distance of 50 m. beyond the building area stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering (including shoring and strutting) etc. complete. (Lift upto 1.50 Metre). by Mechanical means Spec. No. : Bd.A.1 Page No. 259. SSR I.No. 21.02 |
| 2 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift 1.5 m. to 3.0m)By Mechanical Means. dSR I.no. 21.04 |
| 3 | Providing and filling in the foundation with sand of approved quality including watering, compacting etc. complete. (To be executed with prior approval of Superintending Engineer) DSR I.no. 21.39 |
| 4 | Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. DSR I.no. 21.38 |
| 5 | Providing and laying cast in situ / Ready mix , cement concrete in M10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, form work, compacting, roughing them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reverisble drum type mixer/concrete batch mix plant (pan mixer) etc complete finishing if required and curing etc. complete. Spec. No. : Bdf3. SSR I.No. 24.01. Page. no. 217 |
| 6 | Providing and laying in situ / Ready mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete work in foundation like raft, grillages, strip foundation and footings of reinforced cement concrete columns and steel stanchionetc including bailing out water, form work, compaction and finishing, curingroughening the surface if special finish is to be provided (excluding reinforcemetn anf structural steel) etc. complete with fully automatic micro processor based PLC with SCADA enabled reverisble drum type mixer/concrete batch mix plant (pan mixer) etc complete with fine aggregate (Natural sand / CRushed sand VSI grade finely washed etc ) finishing if required and curing etc Spec. No. : Bd.F.3 Page No. 298. and B.7 , Page. No. 38 S.S.R.I. I.No. 25.11. |
| 7 | Providing and laying in situ / Ready mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete columns as per detailed design and drawing or as directed including steel centreing, formwork, , cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complte (excluding reinforcemetn anf structural steel) etc. complete with fully automatic micro processor based PLC with SCADA enabled reverisble drum type mixer/concrete batch mix plant (pan mixer) etc complete with fine aggregate (Natural sand / CRushed sand VSI grade finely washed etc ) finishing if required and curing etc Spec. No. : Bd.F.5 Page No. 300. and B.7 , Page. No. 38 S.S.R.I. I.No. 25.31 Page. No. 222. |
| 8 | Providing and laying in situ / Ready mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete beams and lintelsas per detailed design and drawing or as directed including steel centreing, formwork, , ocver blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complte (excluding reinforcemetn anf structural steel) etc. complete with fully automatic micro processor based PLC with SCADA enabled reverisble drum type mixer/concrete batch mix plant (pan mixer) etc complete with fine aggregate (Natural sand / CRushed sand VSI grade finely washed etc ) finishing if required and curing etc Spec. No. : Bd.F.6 Page No. 300. and B.7 , Page. No. 38 S.S.R.I. I.No. 25.50. |
| 9 | Providing and laying in situ / Ready mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete slabs and landings as per detailed design and drawing or as directed including steel centreing, formwork, , ocver blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complte (excluding reinforcemetn anf structural steel) etc. complete with fully automatic micro processor based PLC with SCADA enabled reverisble drum type mixer/concrete batch mix plant (pan mixer) etc complete with fine aggregate (Natural sand / CRushed sand VSI grade finely washed etc ) finishing if required and curing etc Spec. No. : S.S.R.I. I.No. 25.70 |
| 10 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc)SSR I.No. 26.05 |
| 11 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. DSR I.No. 26.33 |
| 12 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in plinth as backing in composite masonry including bailing out water manually, striking joints, raking out joints and watering etc Complete. SSSR I.No.27.01 |
| 13 | Filling in plinth and floors with contractor\"s soil, sand or murum in 15 cm. to 20 cm. layers includingwatering and compaction etc. complete. Spec. No. : Bd.A.11 Page No. 263. SSR I.No.21.37 |
| 14 | Providing and fixing frame with / without ventilator of size as specified with Country non teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete. DSR I.no. 39.02 |
| 15 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete DSR I.no. 27.05 |
| 16 | Providing and fixing solid core flush door shutter commercial in single leaf 32 mm thick without ventilator commercial type of exterior grade as per detailed drawings with wrought iron hold fast, stainless steel fixtures and fastenings and handles on both sides and finishing with oil painting 3 coats complete. DSR I.no. 39.10 |
| 17 | Providing and fixing mild steel grill work for windows, ventilators, etc. 15 kg/sqm as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete. DSR I.No. 40.02 |
| 18 | Providing and fixing steel window of various sizes as per detailed drawing without hot dip zinc coating, without ventilators, including fabricating / glazing with plain / obscured glass panels of approved type and quality, iron oxidised fixtures and fastenings, oil painting two coats complete. DSR I.No. 39.19 |
| 19 | Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. DSR I.no. 32.04 |
| 20 | Providing internal cement plaster 20mm thick in two coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curingetc.complete. DSR I.No. 32.07 |
| 21 | Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. DSR I.no. 36.11 |
| 22 | Providing and applying two coats of water proof cement paint of approved manufacture and of approved colour to the plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc.complete. DSR I.no. 35.13 |
| 23 | Providing and applying two coats of lead/zinc base oil paint/bituminious paint of approved colour and shade to old wood work and fiber boards previously painted including if necessary scaffolding, preparing the surface excluding priming coat etc.complete. DSR I.No. 35.03 |