| Sl. No. | Item Description |
| 1 | Demolition of cement concrete (un reinforced) in ground floors and paving n. exc. 15cm thickness (below or above ground level) removing rubbish off the premises etc complete all as directed. |
| 2 | Demolition of reinforced concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for, removing rubbish off the premises etc complete all as directed. |
| 3 | Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as directed. |
| 4 | Dismantling timber scantlings 40 Sq.cm and over in section, in any position complete all as specified and as directed. |
| 5 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. complete all as specified and directed. |
| 6 | Taking down chowkhats or frame with shutters (without taking off shutters from the frame) not exceeding 1.50 Sqm each complete all as directed. |
| 7 | Taking down chowkhats or framewith shutters (without taking off shutters from frames) exceeding 1.5 Sqmbut not exceeding 4 Sqm each complete all as directed. |
| 8 | Taking down shutters of any description not exceeding 1 Sqm each complete all as specified and as directed. |
| 9 | Refixing of shutters of any description in same opening not exceeding 1 Sqm each complete all as specified and as directed. |
| 10 | Taking down shutters of any descriptionexceeding 1 Sqm but not exceeding 2 Sqm each complete all as directed. |
| 11 | Refixing of shutters of any description in same openingexceeding 1 Sqm but not exceeding 2 Sqm each complete all as directed. |
| 12 | Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings any thickness, complete all as specified and directed. |
| 13 | Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs of any thickness including cover fillets complete all as directed. |
| 14 | Taking down cement plaster or cement lime plaster on walls /ceiling of any description from concrete or brick wall etc including raking out joints, hacking for key, scrubbing down with water and disposing off the retreived debris as directed including necessary scaffoldings etc complete all as directed. |
| 15 | Hacking out old broken glasses (any thickness/type and in any position) from wooden frames/ metal frames fixed with oil putty or beads etc and removing from site complete all as directed. |
| 16 | Taking up or down 15mm bore steel tubing and connections including cleaning for refixing or removal from site complete all as specified and as directed. |
| 17 | Taking up or down 20mm bore steel tubing and connections including cleaning for refixing or removal from site complete all as specified and as directed. |
| 18 | M&L for cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed. |
| 19 | M&L for reinforced cement concrete(1:2:4) type B-1 (Nominal Mix) (using 20 mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified anddirected. |
| 20 | M&L for brick work with sub class \"B\" burnt clay bricks straight or curved on plan exc 6 meter mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 21 | M&L for brick work with sub class \"B\" burnt clay bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed. |
| 22 | M&L for cutting chases, pinning in making good to facings where required and pointing in cement motar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring, etc and making good, cutting not exc 10 cm girth in brick walls complete all as specified and directed. |
| 23 | Use and waste of form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. rough finished flat surface of concrete complete all as specified and as directed. |
| 24 | M&L for second class hardwood, scantlings, wrought, in unframed work complete all as specified and directed. |
| 25 | S&F 30 mm thick, second class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (b). |
| 26 | S&F 35 mm thick, second class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (b). |
| 27 | M&L for 35 mm thick 2nd class hardwood plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed. |
| 28 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing, complete all as specified and directed. |
| 29 | S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification and drawing, complete all as specified and directed. |
| 30 | S&F 150 mm long, aluminium, barrel tower bolts of extruded section of aluminium alloy, anodised finish not be less than Grade AC 10 of IS 1868:1996 with transparent anodic filmcomplete all as specified and as directed. |
| 31 | S&F in repair 150 mm long, aluminium, barrel tower bolts of extruded section of aluminium alloy, anodised finish not be less than Grade AC 10 of IS 1868:1996 with transparent anodic filmcomplete all as specified and as directed. |
| 32 | S&F 100 mm long, aluminium, barrel tower bolts of extruded section of aluminium alloy, anodised finish not be less than Grade AC 10 of IS 1868:1996 with transparent anodic filmcomplete all as specified and as directed. |
| 33 | S&F in repair 100 mm long, aluminium, barrel tower bolts of extruded section of aluminium alloy, anodised finish not be less than Grade AC 10 of IS 1868:1996 with transparent anodic filmcomplete all as specified and as directed. |
| 34 | S&F aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sectionsor cast aluminium alloy, length of bolt of 300 mm anodised finish not be less than Grade AC 10 of IS 1868:1996 complete all as specified and as directed. |
| 35 | S&F in repair aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sectionsor cast aluminium alloy, length of bolt of 300 mm anodised finish not be less than Grade AC 10 of IS 1868:1996 complete all as specified and as directed. |
| 36 | S&F Mild steel butt hinges, Medium grade, 75 mm size , complete all as specified and directed. |
| 37 | S&F in repair Mild steel butt hinges, Medium grade, 75 mm size , complete all as specified and directed. |
| 38 | S&F Mild steel butt hinges, Medium grade, 100 mm size , complete all as specified and directed. |
| 39 | S&F in repair Mild steel butt hinges, Medium grade, 100 mm size , complete all as specified and directed. |
| 40 | S&F mild steel 375 mm ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed. |
| 41 | S&F for 150 mm size, aluminium handles, cast type, anodised to a bright natural, mat finish not be less than Grade AC 10 of IS 1868:1996 complete all as specified and as directed. |
| 42 | S&F in repair 150 mm size, aluminium handles, cast type, anodised to a bright natural, mat finish not be less than Grade AC 10 of IS 1868:1996 complete all as specified and as directed. |
| 43 | S&F 100 mm size, aluminium handles, cast type, anodised to a bright natural, mat finish not be less than Grade AC 10 of IS 1868:1996 complete all as specified and as directed. |
| 44 | S&F in repair 100 mm size, aluminium handles, cast type, anodised to a bright natural, mat finish not be less than Grade AC 10 of IS 1868:1996 complete all as specified and as directed. |
| 45 | S&F in repairs harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers, etc as in curtain rail complete all as specified and as directed. |
| 46 | S&F galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed. |
| 47 | S&F in repair galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed. |
| 48 | M&L for TMT bars 10 mm dia and over, as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed. |
| 49 | S&F pressed steel door frames conforming to IS : 4351, manufactured from commercial mild steel sheet of 1.25 mm thickness, size 125 mm x 60 mm, profile C, single rebate including hinges, mortar guards, lock strike plate, shock absorbers including PCC (1:2:4) type B-1 for filling of hollow section complete all as specified and as directed. |
| 50 | S&F pressed steel door frames conforming to IS : 4351, manufactured from commercial mild steel sheet of 1.25 mm thickness, size 105 mm x 60 mm, profile C, single rebate including hinges, mortar guards, lock strike plate, shock absorbers including PCC (1:2:4) type B-1 for filling of hollow section complete all as specified and as directed. |
| 51 | M&L for anodised aluminium window and ventilator shutters, fixed type, with or without sash bar, using aluminium section weighing not less than 0.55Kg per metre including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading,handle 2 Nos in each shutter, screws etc complete all as specified and as directed. |
| 52 | S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge |
| 53 | S&F aluminium anodised snap grid frame work of size 605mm x 605mm frame work for ceiling with aluminium tee section of size 23.5mm x 26.4mm x 1.4mm thick and aluminium angle section of size 36.5mm x 25mm x 1.4mm thick, for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long including 4 mm thick non asbestos E-board (plain), HSPC fixed to frameincluding providing two coats of white wash complete all as specified and as directed.Make of E-Board : Eternit Everest / Lafarge/ Armstrong/Visaka Industries Ltd. |
| 54 | M&L for 18/19 mm thick pre-laminated particle board exterior grade pre-laminated one side with decorative choice laminatedand other side balancing white lamination fixed with screws to timber frame work as in cup board shutters, partitions and shelves complete as specified and directed. |
| 55 | S&F in repairs 18/19 mm thick pre-laminated particle board exterior grade pre-laminated one side with decorative choice laminatedand other side balancing white lamination fixed with screws to timber frame work as in cup board shutters, partitions and shelves complete as specified and directed. |
| 56 | M&L for water proofing treatment on RCC roof etc. comprising with the following operation & as specified herein below:-(a)Taking down existing old tarfelt, bituminous compoundincluding cleaning & removing debris to a distance exc 100 m n.exc.250m.(b) M&L 25 thick cement concrete type B0 1:2:4 (12.5 mm graded aggregate) finished even and smooth.(c) Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight). (d) M&L for 20 mm thick screed bed in cement mortar 1:4 finished even and smooth.(e) Preparing & cleaning of fully dried cement plastered surface.(f) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 liters per sqm conforming IS-3384.(g) A layer of APP based polymeric membrane3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyester non woven fabric(weighing not less than 160 gms/sqm) shall be applied over bituminous primer as specified above.Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction.(h) One coat of aluminium paint over APP membrane @0.11Kg/Sqm.Note:-Prior to execution of the APP Membrane works, leak proof test shall be done by ponding water on roof slab to minimum depth of 25 mm. The entire roof slab shall be flooded with water for 48 hours. The necessary barrier shall be made to make feasible to stagnate water for 48 hours on roof slab. |
| 57 | M&L for 75 mm thick,plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection/ hard standing etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand (1:2) complete all as specified and as directed. |
| 58 | M&L for 40 mm thick PCC (1:2:4)type B0 (using 12.5 mm graded stone aggregate) as in sub base of floors finished even and smooth with using extra cement, complete all as specified and directed. |
| 59 | M&L for non-skid, ceramic, coloured tiles 8 to 10 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, including 15 mm thick screed bed or bedding in cement mortor (1:6) and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed. |
| 60 | M&L for non skid ceramic colouredtiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles with and including 15mm thick screed bed or bedding layer of cement morter (1:6) for laying of floor finishes complete all as specified and directed. |
| 61 | M&L for glazed ceramic tiles in vertical surface 300x 200x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match with the shade of tiles over and including 10mm thickbacking coat in cement mortar (1:4) complete all as specified and directed. |
| 62 | M&L for coloured 450x350x7-8 mm thick glazed ceramic tileson vertical surfaces such as skirting, dado and risers to steps etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, over and including 10mm thickbacking coat in cement mortar (1:4) , complete all as specified and directed. |
| 63 | M&L for vitrified, ceramic, coloured (light shade) tiles 10mm thick (square/rectangular) area of each tile exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc, including 15 mm thick screed bed or bedding in cement mortar (1:6) and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed. |
| 64 | M&L for vitrified, ceramic, coloured (light shade) tiles 10mm thick (square/rectangular) area of each tile exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc, including 15 mm thick screed bed or bedding in cement mortar (1:4) and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed. |
| 65 | M&L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, Jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15mm thick screed bedin cement mortar (1:4) complete all as specified and as directed. |
| 66 | M&L for rendering 5mm thickin cement morter (1:3) on ceiling surfaces, finished even and smoothwithout using extra cement, complete all as specified and directed. |
| 67 | M&L for rendering 10 mm thick wall on fair faces of brick work or concrete surfaces in cement mortar in (1:6) andfinished even and smooth (without using extra lime or cement) complete all as specified and as directed. |
| 68 | M&L for rendering 15 mm thick on fair faces of external wall of brick work or stone surfaces in two layers (10 mm and 5 mm thick) in cement mortar in (1:4) using water proofing compound in top layer andfinished even and smooth (without using extra lime or cement) complete all as specified and directed.Note:Water Proofing Compound measured and paid separately. |
| 69 | Supply only liquid Water Proofing Compound ISI marked of approved make complete all as specified and directed. |
| 70 | M&L for preparation of old decorated plastered surfaces of walls by brooming down or steel wire brushing, scraping down with steel scraper, smoke soot, moulds moss and efflorescent salts, trading oil and greasy spots and applying two coat of white wash complete all as specified and as directed. |
| 71 | M&L for preparation of old decorated plastered surfaces of ceilings by brooming down or steel wire brushing, scraping down with steel scraper, smoke soot, moulds moss and efflorescent salts, trading oil and greasy spots and applying one coat of white wash complete all as specified and as directed. |
| 72 | M&L for preparation of old plastered surfaces of walls by washing, rubbing down and scraping of existing distempering/painted surfaces etc and applying one coat of distemper oil emulsion complete all as specified and as directed. |
| 73 | M&L for applying three coats of white wash on new Wall surfaces including preparation of surface, complete all as specified and directed. |
| 74 | M&L for applying three coats of white wash on new ceiling surface including preparation of surface, complete all as specified and directed. |
| 75 | M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper of approved colour with roller over one coat of primerafter preparation of surface completeall as specified and directed. |
| 76 | M&L for preparation of plastered surface of external walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed. |
| 77 | M&L for preparation of old plastered surfaces of walls by complete removal of existing treatment including chalk whiting on wall etc and applying two coat of distemper oil emulsion over a coat of chalk whiting primer for distemper including wall care putty (minimum 1.5mm thick) complete all as specified and as directed. |
| 78 | M&L for 3mm thick wall care putty on wall complete all as specified and as directed. |
| 79 | M&L for 3mm thick wall care putty on ceiling complete all as specified and as directed. |
| 80 | S&F 4.0 mm thick sheet glass, ordinary quality and glazing with oil putty in squaresexceeding 0.50sqm in each pane complete all as specified and directed. |
| 81 | S&F for 4.0 mm thick, figured glass, pin head type and glazing with oil puttyin square not exceeding 0.5 Sqm in each pane complete all as specified and as directed. |
| 82 | S&F 5.50 mm thick, sheet glass,ordinary quality and glazing with oil puttyin square exceeding 0.5 Sqm in each pane complete all as specified and as directed. |
| 83 | M&L for preparation of old painted wood and wood based surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 84 | M&L for preparing of new wooden surfaces of any description , over 10 cm width or girthand applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed. |
| 85 | M&L for preparation of old painted wooden surfaces of any description not exceeding 10 cm width or girth when unconnected with other painting or when painted in different tint and applying one coat of synthetic enamel paintall as specified and as directed. |
| 86 | M&L for preparation of old painted steel surfaces of any description, over 10 cm in width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 87 | M&L for preparation of old painted steel surfaces of any description, over 10 cm in width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 88 | S&F 15 mm bore medium grade galvanized steel water tubingwith all fittings, fixed to wall/ceiling or laid in floor complete all as specified. |
| 89 | S&F 20 mm bore medium grade galvanized steel water tubingwith all fittings, fixed to wall/ceiling or laid in floor complete all as specified. |
| 90 | S&F in repair toilet paper holder of vitreous china, fixed to walls with chromimum plated brass screws complete all as directed. |
| 91 | S&F 15mm bore dia Stop valves fancy type, chromium plated, with long shank and cup (concealed type) cast copper alloy screwed down high pressure with crutch or butter fly handle serwed both ends for iron pipe or for unions complete all as specified and as directed. |
| 92 | S&F 20mm bore dia Stop valves fancy type, chromium plated, with long shank and cup (concealed type) cast copper alloy screwed down high pressure with crutch or butter fly handle serwed both ends for iron pipe or for unions complete all as specified and as directed. |
| 93 | S&F sinks made of stainless steel 1.0mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or includingfixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowL size 410mm x 330mm x 160mm complete all as specified and directed. |
| 94 | S&F in repairs sinks made of stainless steel 1.0mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or includingfixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowL size 410mm x 330mm x 160mm complete all as specified and directed. |
| 95 | S&F in repair grating doom, circular type, 100mm dia of PTMT, (mimimum weigh 25 gms) complete all as specified and as directed. |
| 96 | S&F for 6 mm thick asbestos cement two piece adjustable serrated ridge for corrugated or semi corrugated sheet, fixed with \"L\" type or \"J\" type hook or cranked hook bolt withwasher complete all as specified and as directed. |
| 97 | M&L for 6 mm thick asbestos cement sheet, corrugated, or semi corrugated sheets as in roofs, etc. and fixed with \"L\" type or \"J\"-type or cranked hook bolts, complete all as specified and as directed. |
| 98 | S&F in repair Vitreous Chinawash down water closet pan (pedestal pattern), white with \"P\" or \"S\" Trap complete all as specified and directed. |
| 99 | S&F Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device. |
| 100 | S&F in repairs Vitreous China squatting pan, `Orrisa\" pattern, size 580 x440 mm white, with integral foot rests (including flushing cistern & flush pipe) incl setting the trap and pan in cement mortar (1:3:6) all round and \"P\" or \"S\" Trap, complete all as specified and directed. |
| 101 | S&F in repairs Vitreous China wash hand basin, white, flat back, size 550x400mm with coupling , waste, chain and plug andporcelainstopper, brackets, with and incl 32mm dia 90cm long PVC waste down pipe, but excluding taps complete all as specified and directed. |
| 102 | S&F in repairs PTMT(half or full threaded) waste coupling 32mm for sink (min weight 32mm - 45gms/40mm - 60gms) complete all as specified and as directed. |
| 103 | S&F in repairs PTMT(half or full threaded) waste coupling 40mm for sink (min weight 32mm - 45gms/40mm - 60gms) complete all as specified and as directed. |
| 104 | S&F in repairs, 15mm cromium plated Bib taps, cast copper alloy with crutch orbutterfly handle, fancy type,screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed. |
| 105 | S&F in repair cromium plated Pillar taps 15 mm bore, cast copper alloy, with capstan heads screwed down high pressure, with or without lettered `Hot\" or `Cold\" with long screwed shanks & fly-nuts, screwed for iron pipe, complete all as specified and directed. |
| 106 | S&F in repairs 15mm bore dia Stop cock cast copper fancy type chromium plated alloy screwed down high pressure with crutch or butter fly handle serwed both ends for iron pipe or for unions complete all as specified and as directed. |
| 107 | S&F in repairs 20mm bore dia Stop cock cast copper fancy type chromium plated alloy screwed down high pressure with crutch or butter fly handle serwed both ends for iron pipe or for unions complete all as specified and as directed. |
| 108 | S&F in repairs 15mm bore, PVC connection pipe 600 mm long with PTMT nuts at both ends complete all as specified and as directed. |
| 109 | S&F in repair PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed. |
| 110 | S&F in repair 110mm bore, PVC (SWR) pipes type \"B\", single socketed in any length with rubber ring joints fixed to walls using MS holder bat, fixed complete all as specified and as directed. |
| 111 | S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed. |
| 112 | S&F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed |
| 113 | S&F inrepair 110 mm bore, PVC (SWR) bends of any radius complete all as specified and as directed. |
| 114 | S&F in repairs 75 mm bore, PVC (SWR) bends of any radius complete all as specified and as directed. |
| 115 | S&F in repair PVC (SWR)junction single, (single T) equal or unequal, 75 mm bore complete all as specified and directed. |
| 116 | S&F in repair PVC (SWR)junction single, (single T) equal or unequal, 110 mm bore complete all as specified and directed. |
| 117 | S&F in repair PVC (SWR)junction single, (double T) equal or unequal, 75 mm bore complete all as specified and directed. |
| 118 | S&F in repair PVC (SWR)junction single, (double T) equal or unequal, 110 mm bore complete all as specified and directed. |
| 119 | S&F in repairs PVC (SWR) branch piece single (single Y) 110mm bore with access door complete all as specified and as directed. |
| 120 | S&F in repairs PVC (SWR) branch piece single (single Y) 75mm bore with access door complete all as specified and as directed. |
| 121 | S&F in repairs PVC (SWR) branch piece single (double Y) 110mm bore with access door complete all as specified and as directed. |
| 122 | S&F in repairs PVC (SWR) branch piece single (double Y) 75mm bore with access door complete all as specified and as directed. |
| 123 | M&L for PVC (SWR) floor trap dia of outlet 75mm, plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 124 | S&F in repair brass chromium plated shower rose, 125mm size with shower arm 15mm size, 195mm long with bend of 45 degree with flange complete all as specified and as directed. |
| 125 | S&F in repair PVC low level flushing cistern, 10 litre capacity, valveless, symphonic action type with inlet, ball valve, float and handle incl bracket, PVC conection pipe andflush pipe of polyethylene of low or high density or PVC 32 mm dia complete all as specified and directed |
| 126 | S&F in repair Tubular towel rail, 20mm dia, D type, 60cm long Brass Chromium plated between flanges complete all as specified and as directed |
| 127 | S&F in repairs brass chromium plated, soap dish, fixed to plugs with chromium plated brass screwscomplete all as specified and as directed. |
| 128 | M&L for cleaning and removing all scale and dirt, etc, from tanks exc.250 Ltrs not exc. 500 Ltrs and from mouths of circulating pipes, etc. complete all as specified and as directed. |
| 129 | M&L for cleaning and removing all scale and dirt, etc, from tanks exc.500 Ltrs not exc. 1000 Ltrs and from mouths of circulating pipes, etc. complete all as specified and as directed. |
| 130 | S&F 500 litres capacityrotational moulded polyethylene water storage tanks (cylindrical or vertical with closed top) as per IS 12701:1996, hoisted and fixed in position including provision of 20/15mm bore medium grade pipe for connecting inlet, outlet, overflow and washout pipe incl 20 mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (minimum weight 20 mm - 210 gms ) complete all as specified and as directed. |
| 131 | S&F 1000 litres capacityrotational moulded polyethylene water storage tanks (cylindrical or vertical with closed top) as per IS 12701:1996, hoisted and fixed in position including provision of 20/15mm bore medium grade pipe for connecting inlet, outlet, overflow and washout pipe and incl 20 mm bore,ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) complete all as specified and as directed. |
| 132 | Dismantling water tanks and removing to store of (exceeding 251 liter & not exceeding 500 liter capacity) complete all as specified and as directed. |
| 133 | Dismantling water tanks and removing to store of (exceeding 501 liter & not exceeding 100 liter capacity) complete all as specified and as directed. |
| 134 | S&F in repair 15 mm bore Gun metal gate or globe valve with iron wheel head screwed both ends for iron pipe complete all as specified and directed. |
| 135 | S&F in repair 20 mm bore Gun metal gate or globe valve with iron wheel head screwed both ends for iron pipe complete all as specified and directed. |
| 136 | S&F 20 mm bore, ball brass valves, high pressure, with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed. |
| 137 | S&F in repair 20 mm bore, ball brass valves, high pressure, with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed. |
| 138 | S&F in repair 600mmX450mm bevelled edge mirror of selected quality 5mm thick glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated cup washers and screws complete all as specified and as directed. |
| 139 | S&F Jet spray universal complete all as specified and as directed |
| 140 | S&F in repair health faucet cast copper alloy with push button & 1m long flexible steel pipe with PVC lining suitable for 15mm bore pipe complete all as specified and directed. |
| 141 | S&F 15mm dia angular stop cock with wall flange all as specified and directed. |
| 142 | S&F Parryware corner shelf all as specified and directed |
| 143 | S&F PVC waste pipe of 32mm size flexible and 1.2 mtr long, fitted to basin or sink complete all as specified and as directed. |
| 144 | S&F in repairs PVC mirror cabinet (440x325x120mm) and fixed to wall after taking down old mirror all as specified and directed. |
| 145 | S&F Parryware wall mixer 3-in-1 all as specified and directed. |
| 146 | M&L for pelmet boxes or in narrow widths n. exc 15cm each, 12mm thick particle board, medium density, flat pressed, single layer type or three layer type with BWR type adhesive, fixed with screws to timber frame work complete all as specified and as directed. |