| 1 | NOTE:- (Applicable for all parts/items/):- The bidders/contractorsare advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. |
| 2 | Lumpsum price workedout by the tenderer for BUILDING& STRUCTURE WORKS as listed in Schedule ‘A’ Part-I |
| 3 | Lumpsum price worked out by the bidder/ tenderer forSITE CLEARANCE, SITE DEVELOPMENTS & EARTH WORKS as listed in Schedule \"A\" Part-II. |
| 4 | Lumpsum price worked out by the bidder/ tenderer for DEMOLITION OF B/R & E/M WORKSas listed in Schedule \"A\" Part-III. |
| 5 | Lumpsum price worked out by the bidder/ tenderer forINTERNAL ELECTRIFICATIONas listed in Schedule \"A\" Part-IV. |
| 6 | Lumpsum price worked out by the bidder/ tenderer for HOT WATER SUPPLY as listed in Schedule \"A\" Part-V. |
| 7 | Lumpsum price worked out by the bidder/ tenderer for REFRIGERATION as listed in Schedule \"A\" Part-VI. |
| 8 | Lumpsum price worked out by the bidder/ tenderer for LIFT as listed in Schedule \"A\" Part-VII. |
| 9 | Lumpsum price worked out by the bidder/ tenderer for DG SET as listed in Schedule \"A\" Part-VIII. |
| 10 | Lumpsum price worked out by the bidder/ tenderer for ROAD , PATH,CULVERT , HARD STANDING ANDHUME PIPE as listed in Schedule \"A\" Part-IX. |
| 11 | Lumpsum price worked out by the bidder/ tenderer for EXTERNAL WATER SUPPLY as listed in Schedule \"A\" Part-X. |
| 12 | Lumpsum price worked out by the bidder/ tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule \"A\" Part-XI. |
| 13 | Lumpsum price worked out by the bidder/ tenderer for SEWAGE DISPOSAL as listed in Schedule \"A\" Part-XII. |
| 14 | Lumpsum price worked out by the bidder/ tenderer for AREA DRAINAGE as listed in Schedule \"A\" Part-XIII. |
| 15 | Lumpsum price worked out by the bidder/ tenderer for RETAINING WALL as listed in Schedule \"A\" Part-XIV. |
| 16 | Lumpsum price worked out by the bidder/ tenderer for INTERNAL WATER SUPPLY as listed in Schedule \"A\" Part-XV. |
| 17 | Sch \"A\" Sec-XVI (Miscellaneous Items) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as \"Rs 0.00\" under Col. 5 siginifies this fact only. |
| 18 | Taking down MCB DB TPN/SPN 8/4 way and depositing the same to MES Store complete all as directed. |
| 19 | Taking down MCB (SP/SPN of any capacity) and depositing the same to MES Store complete all as directed. |
| 20 | Taking down old service connection wire from pole to DB and removing GI bracket and depositing same to MES Store complete all as directed. |
| 21 | Demolition of GI wire earthing including removing GI wire from each pit to DB complete all as directed. |
| 22 | S&F LED type bed side wall mounted light fitting 9/10 Watt , housing- glass, frosted type, metallic frame, adjustable type complete all as specified and directed. |
| 23 | S&F Modular blanking plate modular type suitable for fixing in modular switch board complete all as specified and as directed. |
| 24 | S&F Surge Protection Device (SPD) Single Phase and neutral, T2 -limb, Imax 20 KA per pole complete fixed in distribution board and making connections complete all as specified and directed |
| 25 | Supply, installation, commissioning and testing of Indoor type LT feeder piller box of size 900x1200x300 mm,outdoorcubical type, floor mounted, vermin proof factory made of CRCA Sheet 2.0 mm thickand MS angle of size 40x40x5mm having suitable legs, double door both side openable with locking and key arrangement with two Nos pad lock50 mm make Godrej/Harison,powder coated with three phase, 415 volts, 50 Hz, AC supply complete all as directed and comprising of the following:-(a) INCOMING(i) MCCB, 4 Pole, 415 Volts, 400 Amps, breaking capacity 36 KA having thermal setting 100% and magnetic setting upto 70% - 01 No(ii)LED indicating lamp with holder for main supply indicating RYB (set of three) - 01 Set(b) OUTGOING(i) Aluminium busbar of rating 600 Amps, Insulated,3 phase 4 wire system. |
| 26 | S&F Surge Protection Device (SPD) 4 module, 25 KA,3Ph+N Right, T1+T2, limp 8 KA per pole, T2-60KA, complete fixed in Essential DB and making connections by using necessary thimble/washersetc of copper/brass material complete all as specified and directed. |
| 27 | S&F digital time switch 2 module, with Astronomical Function for swtching ON/OFF lights according to sun rising/ sun setting, with combination function for creating switching programs in which the devices are switched according to astronomical time and/ or fixed preset times, having daily astronomical calculation of the sunrise/sunset times based on the entered location or location coordinates complete having 2 output 16 AMps, 250 volts, 50 HZ, Astronomical function 2x28 programs 2 channel, suitable for din rail mounting in Essential DB complete all as specified and direcetd. |
| 28 | Supply , installation, testing and comission of Smart energyMeter (IS-16444), AC whole current, three phase, 4 wires CT Operated Smart Energy Meter of Class 0.5 S, 415 Volts, 50 Hz, 1b 5 A complete as specified in CEA notification.The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I in a secure manner. The slection of communication technology should be as per the site conditions and as per design consideration of AMI Implementing agency to meet the performance. The smart meters should be based on RF Mesh communication technology or Cellular communication technolog. The meter shall be provided with transperent polycarbonate ABS thermoplastic box with sealing arrangement of suitable size as per the requirement of OEM of Electric meter. The cost of meter would be included the supply of current transformer, Rated burden 15 VA, Accuracy class 0.5 S, frequency 50 HZ and voltage class 660 Volts effectively earthed and CT ratio suitable as (60/5 to 1000/5) complete all as specified and directed. NOTE:(a) The bidder shall provide replacement warranty of 5 Years from the date of activation of smart meter for any type of Defect/ Fault/ Error in reading/ Non functioning of smart feature.(b)CT to be provided at incommer side of MCCB in main LT panel of the Building. |
| 29 | Supply , installation, testing and comission of Smart energy prepaid Meterconfirming to IS-16444: 2015 (Reaffirmed 2020) and as ammended time to time, AC whole current, three phase, 4 wires Smart Energy Meter of rating 415 Volt, 10-100 Amps,50 Hz , Class 1, enclosed in polycarbonate box complete as specified in CEA notification. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I. The slection of communication technology should be as per the site conditions and as per design consideration of AMI Implementing agency to meet the performance. The smart meters should be based on RF Mesh communication technology or Cellular communication technology and carry min 5 yrs warranty. |
| 30 | Supply Installation and testing of Refrigerator double door run on digital inverter technology with latest specification or features of capacity 320 Ltrs with 5 star rated complete all as specified and directed |
| 31 | S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 135 V to 280 V with output voltage stabilized at 230 V with accuracy of+ 2.5% and of cap 4 Amps ( 1.0 KVA) complete all as specified and directed. |
| 32 | Design, Supply, Installation, Testing and commissioning incl comprehensive maint for 5 years of Roof Top Solar Power Generation Plant of capacity 30 KWp (AC) at output Voltage 415 Volt, 50Hz, on grid connected complete with structure and foundation comprises Design and construction of foundation, civil supporting structure, modules, inverters, DC junction, Distribution & combiner boxes, AC junction & combiner boxes,lighting arrester, weather station, SCADA system, earthing, connecting wires / cables with all accessories required for SPV complete all as per MNRE/SECI specifications and technical specifications asgiven in particular specification (Detail Brief Report and Technical Specification for SPV Plant) complete all as specified and directed |
| 33 | Design, Supply, Erection, Testing and commissioning incl comprehensive maint for 5 years of Roof Top Solar Power Generation Plant of capacity 10 KWp (AC) at output Voltage 415 Volt, 50Hz, ON GRID Hybrid solar roof top with batteries back up for captive use as per specification & complete with structure and foundation comprises Design and construction of foundation, civil supporting structure, modules, inverters, DC junction, Distribution & combiner boxes, AC junction & combiner boxes,lighting arrester, weather station, SCADA system, earthing, connecting wires / cables with all accessories required for SPV complete all as per MNRE/SECI specifications andtechnical specifications asgiven in particular specification (Detail Brief Report and Technical Specification for SPV Plant) complete all as specified and directed |
| 34 | Design, Construction, Supply, installation, testing and commissioning of compact & concealed designed Sewage Treatment Plant of capacity 25 KLD based on Johkasou technology / (MBBR) Moving Media Bio Reactor Technology / PeMBR technolgyincluding fully automation system (Scada System), modular Pre- constructed systems having sedimentation and seperation chamber, anaerobic contact media chamber, moving bed chamber (Aerobic), sedimentation chamber, disinfectant chamber and tertiary treatment plant, including operation and maintenance for a period of 5 years from the date of completion of work including all consumable except power, with adequate manpower to ensure no downtime of plant and provide consistent outlet parameters, the plant shall be having least energy and operating cost and No noise during operation, complete and including the following:- |
| 35 | Continued serial item No. 16.017(a) Bar screen (Mesh) 500mm x 500mm, made of MS FRP coated, and bar spacing 10 mm complete as per OEM recommendations.(b) Cylindrical type reactor made of FRP complete as per OEM recommendation.C)Air blowerofcapacityas per OEM recommendations complete - 03 Nos.(d) Filter Feed Pump , Non-clog submersible pump of capacity as per OEM recommendations - 02 Nos ( One working + One Standby).(e)Pressure sand filter ofcapacity as per OEM recommendations, made of FRP, having vessel size 18\" dia x 65\" height and having Gravels/Pebbles/Core Silex/Fine Silex/ Sand as filter mediacomplete with necessary PVC piping complete - 01 Set.(f) Activated Carbon filter of capacity as per OEM recommendations, made of FRP, having vessel size 18\" dia x 65\" height and having 1200 I/V Activated carbonfilter mediacomplete with necessary PVC piping complete - 01 Set.(g) Chlorine (Sodium Hypochlorite Dosing) System having Dosing pump of capacityas per OEM recommendations and including HDPE Dosing drum of minimum cpacity 50 Litrs complete - 01 Lot.(h) Raw sewage Transfer Pump of capcity as per OEM recommendations complete - 02 Nos ( One working + One Standby).(j)One No. PLC Panel for operation of the plant as per OEPL standard & cabling with in the plant range complete.(k)Necessary piping & valves as per OEM recommendations within the plant range complete - 01 Lot(l)All as per Scope of Work & Technical Specification for 25 KLD STP given in particular specification |
| 36 | Supply, Installation, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 16 KW (20 KVA),415 Volts (AC three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tankwith mounting arrangements and inlet, outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Dinjan (Capacity of Engine, alternators shall be worked out taking all derating factors into consideration) including PCC foundation (of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), anti-vibration pads, including all features to comply with latest CPCB IV guidelines and Comprising of followings:- (i) ENGINE(Prime Mover): Diesel Engine 1500 RPM , direct injection, 6 cylinders, four stroke, radiator cooled, performance class of generator set ISO 8528-5 G2, turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering16 KW(20 KVA) atoutdoor atmospheric conditions at Dinjan, (Taking all derating factor into consideration),12/24 Volt (as per manufacturer recommendations) electric battery start, complete withy fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with tachometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system (Shut down, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc . |
| 37 | Continued serial item No. 16.018(ii) Alternator: Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 16 KW(20 KVA), Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class \"H\", salient pole, revolving field, sealed bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine :- (iii) BASE PLATE: made out of structural steel as per manufacturers recommended design/specifications.(iv) ACOUSTIC ENCLOSURE: Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition .(v) Foundation/Plinth/Base: Shall be provided as per manufacturers recommendations, however minimum 0.5 m Space should be available all around the Set and height of plinth shall not be less than 0.5 M(vi)Diesel storage tank of capacity adequate for storage of diesel as per manufacturer specification.(vii) AMF Panel: - Microprocessor / Relay based pedestal mounted indoor use AMF control panel of suitable rating made up of 3 mm thick CRCA Sheet steel enclosure duly painted with power coated double contactor type for mains and alternator with necessary aluminum bas bar for 3 phase, 4 wire system incl necessary relays, timer, fuses, interconnection copper cabling work incl fixing on floors by grouting, PCC work complete.(a) MCCB of suitable rating with short circuit protections-1 No (b) Digital multifunction meter of size 96x96 mm to measure current, voltage, KW,frequency and power factor with built in selector switch and programmable CT ratio with RS 485 port(c) Phase indicating lamps(R-Y-B) -1 set(d)All standard relays, circuitsand protection required for automatic operation of Gen set(e) Data logging : Engine hours, Control hours and upto 5 recent fault codes(f) AC Alternator Protection : Over/under Voltage, Over/under frequency, Loss of AC sensing, Over speed, Over Current, KW Overload(viii) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices.(ix) First fill of Lubricants, Coolant & Fuel: -First fill of oil, coolant as per OEM recommendations and diesel during testing for 12 hrs as per CA provn. |
| 38 | Continued serial item No. 16.018Note: PCC foundation for DG Setshall be deemed to be included in the rate quoted for all DG sets: - (a) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Department(b) The contractor shall arrange for artificial load (water load/Electrical load) for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. (c) Testing of sound level should carried out at the site in presence of Engineer-in-Charge(d) One set of latest Spare part catalogue with price, exploded view of parts and user\"s manual are deemed to be included in the offer. (e) All civil works including foundation for DG Set as per manufacturer\"s drawing/ specification, foundation for AMF panel. (f) The rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil. |
| 39 | Supply, Installation, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 12 KW (15 KVA),415 Volts (AC three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tankwith mounting arrangements and inlet, outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Dinjan (Capacity of Engine, alternators shall be worked out taking all derating factors into consideration) including PCC foundation (of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), anti-vibration pads, including all features to comply with latest CPCB IV guidelines and Comprising of followings:- (i) ENGINE(Prime Mover): Diesel Engine 1500 RPM , direct injection, 6 cylinders, four stroke, radiator cooled, performance class of generator set ISO 8528-5 G2, turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering12 KW(15 KVA) atoutdoor atmospheric conditions at Dinjan, (Taking all derating factor into consideration),12/24 Volt (as per manufacturer recommendations) electric battery start, complete withy fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with tachometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system (Shut down, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc . |
| 40 | Continued serial item No. 16.019(ii) Alternator: Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 12 KW (15 KVA), Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class \"H\", salient pole, revolving field, sealed bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine :- (iii) BASE PLATE: made out of structural steel as per manufacturers recommended design/specifications.(iv) ACOUSTIC ENCLOSURE: Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition .(v) Foundation/Plinth/Base: Shall be provided as per manufacturers recommendations, however minimum 0.5 m Space should be available all around the Set and height of plinth shall not be less than 0.5 M(vi)Diesel storage tank of capacity adequate for storage of diesel as per manufacturer specification.(vii) AMF Panel: - Microprocessor / Relay based pedestal mounted indoor use AMF control panel of suitable rating made up of 3 mm thick CRCA Sheet steel enclosure duly painted with power coated double contactor type for mains and alternator with necessary aluminum bas bar for 3 phase, 4 wire system incl necessary relays, timer, fuses, interconnection copper cabling work incl fixing on floors by grouting, PCC work complete.(a) MCCB of suitable rating with short circuit protections-1 No (b) Digital multifunction meter of size 96x96 mm to measure current, voltage, KW,frequency and power factor with built in selector switch and programmable CT ratio with RS 485 port(c) Phase indicating lamps(R-Y-B) -1 set(d)All standard relays, circuitsand protection required for automatic operation of Gen set(e) Data logging : Engine hours, Control hours and upto 5 recent fault codes(f) AC Alternator Protection : Over/under Voltage, Over/under frequency, Loss of AC sensing, Over speed, Over Current, KW Overload(viii) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices.(ix) First fill of Lubricants, Coolant & Fuel: - |
| 41 | Continued serial item No. 16.019First fill of oil, coolant as per OEM recommendations and diesel during testing for 12 hrs as per CA provn.Note: PCC foundation for DG Setshall be deemed to be included in the rate quoted for all DG sets: - (a) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Department(b) The contractor shall arrange for artificial load (water load/Electrical load) for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. (c) Testing of sound level should carried out at the site in presence of Engineer-in-Charge(d) One set of latest Spare part catalogue with price, exploded view of parts and user\"s manual are deemed to be included in the offer. (e) All civil works including foundation for DG Set as per manufacturer\"s drawing/ specification, foundation for AMF panel. (f) The rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil. |
| 42 | Supply, fixing and testing DI fittings for spigot and socketed or flanged pipes i.e bends, reducers, tail pieces, tapers, tees, collars, caps, plugs with MS plate, nuts, bolts, washers, gaskets etc of sizes 80 mm to 150 mm dia complete all as specified and directed. |
| 43 | S&F HDPE pipe 63 mm dia of grade PE 80, nominal pressure rating PN-4, SDR 26 including necessary fittings, fixtures and clamps required complete all as specified and directed. |
| 44 | Shifting, connection ,commisioning and testing of existing transformer upto 500 KVA within happy valley area to proposed site incliding PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above the ground level ) complete complete all as specified anddirected.Note:Cost of crane, labour, PCC foundation, excavation and other accessories required to execute this item shall deemed to be included in quoted rate. |
| 45 | Cutting road upto one feet depth for insertion of cable protection pipe complete all as specified and directed.Note: cable protection pipe and PCC for refilling will be measured and paid separately |
| 46 | Fabrication, supply, installation, testing & commissioning of electrical cubical control panel board (PTTA Panel) factory assembled weather, Dust & Vermin proof, totally enclosed IP-54 protection floor mounted Outdoor factory fabricated of 2.0 mm CRCA MS sheet of suitable size, 3 phase, 4 wire, 415 Volt AC, 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with suitable rating aluminium bus bar insulated with FRP heat shrinkable sleeves of relevant colour with necessary insulators for incoming/outgoing MCCB’s including and mounting measuring instrument such as voltmeter, Ammeter, CT’s Phase LED indicator lamp R-Y-B, selector switch for incoming, cables connection with suitable cable glands, lugs including grouting of feeder pillar box 60 cm above ground level by providing 90 cm long angle iron size 50x50x6 mm welded on all four corner embedded in PCC (1:2:4) using 20mm graded up to 30 cm complete as per IS 8623, IEC 60947 & IS 13947: 1993 complete all as specified and directed.(a) INCOMINGAluminium bus bar capacity 400 Amps for Phase-R-Y-B- & neutral (i) MCCB 4 pole, 415 V, Microprocessor based, Adjustable type, 250 Amp with breaking capacity 36 KA |
| 47 | Continued serial item No. 16.024(ii) Smart energy Meter(IS-16444), AC whole current, three phase, 4 wires, CT operated Smart Energy Meter ofClass 0.5 S, 415 V, 50 Hz, 1b 5A complete all as specified. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I in a secure manner. The selection of communication technology should be as per the site conditions and as per design consideration of AMI Implementing agency to meet the performance. The smart meter can based on RF Mesh communication technology or Cellular communication technology. The meter shall be provided with transperent polycarbonate ABS thermoplastic box with sealing arrangements of suitable size as per the requirement of OEM of Electric meter. The cost of meter would include the supply of current transformer, Rated burden 15 VA, Accuracy class 0.5 S, frequency 50 Hz and voltage class 660V effectively earthed and CT ratio suitable as (60/5 to 1000/5) complete - 01 No(iii) Phase indicator lamps (RYB) - 01 set(b) OUTGOING(i) MCCB 4 pole, 415 V, Microprocessor based, Adjustable type, 200 Amp with breaking capacity 25 KA- 01 Nos (Barrack No-1)(ii) MCCB FP 63 Amps 16 KA - 02 Nos ( CH and DH)(iii) MCB TPN 40 Amps 10 KA - 01 No (C-Curve) (STP)(iv) MCB SPN 20 Amps 10 KA - 01 No (C-Curve) (Street light)(v) Digital timer-01 No(vi) power contractor -01 No |
| 48 | S&F PVC Junction box of size 270 X 225 X 135 mmwiith 2 way connector mounted on epoxy insulators for looping of cablefor 1Phase and1neutral fixed on polewith the help of MS nuts bolts and MS clamps-2 Nos of size 40 mm X4 mm thick . Work also includes making suitable hole in pole to take out connections to fitting if required at site and provisioning of 1.0 sqmm 3.0 core flexible PVC insulated copper cable from junction box to conector of street light complete all as specified and directed. |
| 49 | M&L for DWCP HDPE pipe SN 8 ,100 mm dia complete all as specified and directed. |
| 50 | S&F two way bib cock brass chromium plated with wall flange quarter turn (Low flow) 16 mm dia complete all as specified and directed. |