Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Reinforced cement concrete work in walls (any thickness),including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor fivelevel,excludingcost of centering,shuttering, finishingand reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 2 | Centering and shuttering including strutting, propping etc. and removal of form for: Lintels,beams,plinthbeams,girders,bressumersand cantilevers |
| 3 | Centering and shuttering including strutting, propping etc. and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts |
| 4 | Steelreinforcement forR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treatedbars of gradeFe-500D or more. |
| 5 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6(1 cement : 6 coarse sand) |
| 6 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4(1 cement :4 coarse sand) |
| 7 | Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry. |
| 8 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3(1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 9 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood |
| 10 | Extra for providing heavy sheet float glass panes instead of ordinary float glass in glazed doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured): 5.0 mm thick (weight not less than 12.50 kg per sqm) instead of 4 mm thick (weight not less than 10 kg per sqm). |
| 11 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202(Part I) decorative type,core of block boardconstruction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 12 | Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws:35 mm thick shutters withISImarkedM.S.pressedbutthinges bright finished of required sizeSecond class teak wood |
| 13 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanizedmild steel section madeof requiredshape & size asper CPWDSpecification,uPVC extrudedglazingbeads,interlocksandlnlinesashadaptor(where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum8mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately.Note:-StructuraldesignproofcheckedfromaGovernment Engineering Institute,tobeprovidedbythemanufacturerfor (i) Sites with basic wind speed > 45 m/sec as per IS 875 — Part 3 (ii) Sites with structure height more than 20m for all wind speedsVentilator Casement window single panel with or without fixed panel with S.S. 304 friction hinges as per size and weightof sash,singlepointlockingzincalloy (zannak) powder coated handles.Using R2 series with frame (39 mm & above) x (39 mm & above) & sash /mullion (39 mm & above) x (60 mm & above). (Height upto 1.2 metre) |
| 14 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 15 | ProvidingandlayingVitrified tilesindiferent sizes (thickness tobe specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 1000x1000 mm |
| 16 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab of colour Black,Cherry/Ruby Red or equivalent |
| 17 | Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets andgalvanized with zinc coating of 120 gms/sqm(bothside inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, difusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum moisture resistant board |
| 18 | Providing and fixing precoated galvanised iron profile sheets (size, shape andpitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desiredby Engineer-in-charge. The sheet shallbe fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 19 | 12 mm cement plaster of mix:1:6(1 cement: 6 fine sand) |
| 20 | 15 mm cement plaster on the rough side of single or half brick wall of mix:1:6 (1 cement: 6 fine sand) |
| 21 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour:New work(twoormorecoats)over andincludingwater thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 22 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 Itr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 23 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm |
| 24 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 25 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 26 | Demolishingbrickworkmanually/bymechanicalmeansincluding stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar |
| 27 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead :Of area beyond 3 sq. metres |
| 28 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm |
| 29 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 30 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 31 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board: 510x1040 mm bowl depth 250 mm |
| 32 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi rigid pipe: 32 mm dia |
| 33 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 1500x450 mm |
| 34 | Providing and fixing toilet paper holder :C.P. brass |
| 35 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall: 15 mm nominal dia Pipes |
| 36 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall: 20 mm nominal dia Pipes |
| 37 | ProvidingandfixingChlorinatedPolyvinylChloride(CPVC)pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.15 mm nominal dia Pipes |
| 38 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore |
| 39 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite)soliddoor/window/Clerestorywindows&otherFrames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A categorywithpropertyofbeingtermite/borerproof,water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and lengthcomplete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.edepth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.Frame size 45 x 85 mm |
| 40 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimumcompressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread offlame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge.(Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)30 mm thick |
| 41 | P/F stainless steel sliding door bolts with nuts and srews etc complete . 300X16 MM |
| 42 | P/F stainless steel sliding door bolts with nuts and srews etc complete . 250X16 MM |
| 43 | P/F stainless steel towerbolts with nuts 304 grade and srews etc complete . 300X10 MM |
| 44 | P/F stainless steel towerbolts with nuts 304 grade and srews etc complete . 250X10 MM |
| 45 | P/F stainless steel handleswith nuts 304 grade and srews etc complete . 125 MM |
| 46 | P/F stainless steel handleswith nuts 304 grade and srews etc complete . 100 MM |
| 47 | P/Fstainless steel hanging floor door stoper with necessary screws etc complete/Twin rubber stopper |
| 48 | P/F decorative laminated sheet of high gloss finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS 2046 Type S. including cost of adhesive of approved quality all complete as per direction of Engineer-in-charge/0.80 mm thick |
| 49 | P/FMagic eye for doors of approved design with all necessary fittings as per direction of manufacturer and direction of Engineer-in-charge |
| 50 | P/F CP brass two way bib cock of Jaquar make continental series or equivalent approved quality and as per the direction of Engineer-in-charge. |
| 51 | P/F CP brass wall mixer 2 in 1 of Jaquar make or equivalent for bathroom as per the direction of Engineer-in-Charge |
| 52 | P/F CP brass health faucet of standard designed of Jaquar make as per direction of Engineer-in-Charge |
| 53 | P/F CP Jaquar overhead shower 200X200 mm square single flow chrome as per direction of Engineer-in-charge/15 mm nominal bore |
| 54 | P/F fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in bothe directions with wire of dia 0.50 mm all complete/ With all necessary arrangements and fittings. |
| 55 | Supply and installation of 2 numbers of Zurich High Gloss bed with upholstered headboard and hydraulic storage (Dimension King : W88XD87XH47 inches) |
| 56 | Supply and installation of Naples Italian Bed side table with high glow finish with dimension W21XD15XH19inches |
| 57 | Supply and installation of 2 numbers of Verona Italian round coffee table set of two Table W30XD30XH14 inches, Side table-W18XD18XH17 inches |
| 58 | Supply and installation of 2x2 numbers seating chairs Derby leatherette Sof single chair with revolving mechanismwith W34XD36XH34 inches |
| 59 | Supply and installation of 2 numbers of Zurich High Gloss dresser with Ottorman with dimension W42XD18XH49 inches with modern designed metal legs round mirror with stool. |
| 60 | Supply and installation of 2 numbers of Genuine leather (body touch) 3+1+1 Sofa Set with dimention Length 78 inch x width-31.5 inch x height 35 inch |
| 61 | Fransco Side tables 3x2=06 Nos with stainless steel and paper marble with dimension W21.65xD21.65XH21.65 inches with black and gold colour |
| 62 | Supply and installation of Milan Italian marbel 4 seater dining set with dimension Table W55.11XD33.46XH29.52 inches with Chair W20XD21.2XH39.3 inches |
| 63 | Supply and installation of Milan Italian marbel 4 seater dining set with dimension Table W55.11XD33.46XH29.52 inches with Chair W20XD21.2XH39.3 inches |
| 64 | P/FTable top basin size 580x530x130 mm for bathroom, as per the direction of Engineer-in-Charge |
| 65 | P/F Single towel rail, 600 mm long stainless for bathroom, as per the direction of Engineer-in-Charge |
| 66 | P/F Towel ring square for bathroom, as per the direction of Engineer-in-Charge |
| 67 | P/F Soap dish holder for bathroom, as per the direction of Engineer-in-Charge |
| 68 | P/F Soap dispenser with glass bottle for bathroom, as per the direction of Engineer-in-Charge |
| 69 | P/F Tumbler holder for bathroom, as per the direction of Engineer-in-Charge |
| 70 | P/F Toilet roll holder with stainless steel for bathroom, as per the direction of Engineer-in-Charge |
| 71 | P/F Double coat hook for bathroom, as per the direction of Engineer-in-Charge |
| 72 | P/F Towel rack 600 mm longwith lower hangers for bathroom, as per the direction of Engineer-in-Charge |
| 73 | P/F Concealed body for single lever high FLO for bathroom, as per the direction of Engineer-in-Charge |
| 74 | P/F hand shower( Health faucet) with 8 mm dia, as per the direction of Engineer-in-Charge |
| 75 | P/F Aquamaxt concealed body of thermostatic for bathroom, as per the direction of Engineer-in-Charge |
| 76 | P/F waste coupling 32 mm F.Thread 130 mm HT for bathroom,, as per the direction of Engineer-in-Charge |
| 77 | P/F Bottle trap (with internal partition) for bathroom,, as per the direction Engineer-in-Charge |
| 78 | P/F 600 mm long braided hoses suitable for GE for bathroom,as per the direction Engineer-in-Charge |
| 79 | P/F Single lever tall boywith 125 mm extension for bathroom,as per the direction Engineer-in-Charge |
| 80 | P/F CP 2 way bib cock with wall flange for bathroom,as per the direction Engineer-in-Charge |
| 81 | P/F CP angular stop cock with flange for bathroom,as per the direction Engineer-in-Charge |
| 82 | P/F Aquamax exposed partkit of thermostatic for bathroom,as per the direction Engineer-in-Charge |
| 83 | P/F Single lever exposed parts kit of HI-FLO for bathroom,as per the direction Engineer-in-Charge |
| 84 | P/F Rimiless single piece WC with PPSOFTCLO for bathroom,as per the direction Engineer-in-Charge |
| 85 | P/F Elena prime storage water heater 15 liter for bathroom,as per the direction Engineer-in-Charge |
| 86 | P/F Bolttouch-Freeing frared hand dryer for bathroom,as per the direction Engineer-in-Charge |
| 87 | P/F Maze hand shower 95x95 mm squaresh APESI for bathroom,as per the direction Engineer-in-Charge |
| 88 | P/F Alive maze hand shower 68x100 mm rounded for bathroom,as per the direction Engineer-in-Charge |
| 89 | P/F Single piece-WC with soft closet for bathroom,as per the direction Engineer-in-Charge |
| 90 | P/F Maze overhead shower dia 200x200 mm for bathroom,as per the direction Engineer-in-Charge |
| 91 | P/F wall outlet with shower hook in square for bathroom,as per the direction Engineer-in-Charge |
| 92 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :(FULLY DESIGN & DECORATIVE TYPE)12.5 mm thick tapered edge gypsum moisture resistant board (FULLY DESIGN & DECORATIVE TYPE) |
| 93 | Providing and laying vitrified wall tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete.Size of Tile 1200x2400 mm (RITZY NATURA)Vitrified floor of Tile Size-1200x2400 mm (RITZY NATURA) |
| 94 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete.Vitrified floor of Tile Size-600x1200 mm (PEARLATO PLATINUM) |
| 95 | Providing and fixing 8mm thick toughened glass in door / window uPVC shutter of approved brand and manufacture all complete as per direction of Engineer in charge ( door handle, lock and stopper etc to be paid separately). |
| 96 | Providing and fixing 12mm thick toughened glass in door / window uPVC shutter of approved brand and manufacture all complete as per direction of Engineer in charge ( door handle, lock and stopper etc to be paid separately). |
| 97 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, withmodular switch,modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 98 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copperconductorsinglecorecableinsurface/recessedsteel conduitalongwith 1No. 4sq.mmFRLSPVCinsulatedcopper conductor single core cable for loop earthing as required. |
| 99 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copperconductorsinglecorecableinsurface/recessedsteel conduit alongwith 2Nos.4 sq.mmFRLSPVCinsulated copper conductor single core cable for loop earthing as required. |
| 100 | Wiringforcircuit/submainwiringalongwithearthwirewiththe followingsizesofFRLSPVCinsulatedcopper conductor,single core cable in surface/ recessed steel conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 101 | SupplyinganddrawingfollowingsizesofFRLSPVCinsulated copperconductor, singlecorecableintheexistingsurface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm |
| 102 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.75 mm X 75 mm X 60 mm deep |
| 103 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.150 mm X 75 mm X 60 mm deep |
| 104 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.150 mm X 150 mm X 60 mm deep |
| 105 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.200 mm X 125 mm X 60 mm deep |
| 106 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.200 mm X 150 mm X 60 mm deep |
| 107 | Supplying and fixing following modular switch/ socket on the existing modularplate&switchboxincludingconnectionsbutexcluding modular plate etc. as required.15/16 A switch |
| 108 | Supplying and fixing following modular switch/ socket on the existing modularplate&switchboxincludingconnectionsbutexcluding modular plate etc. as required.3 pin 5/6 A socket outlet |
| 109 | Supplying and fixing following modular switch/ socket on the existing modularplate&switchboxincludingconnectionsbutexcluding modular plate etc. as required.6 pin 15/16 A socket outlet |
| 110 | Supplying and fixing suitable size GI box withmodular plate and cover in front on surface or in recess, including providing and fixing 3pin 5/6Amodularsocketoutlet and 5/6Amodularswitch, connections etc. as required. |
| 111 | Supplying and fixing following way,horizontal type three pole and neutral,sheetsteel,MOBdistributionboard, 415V,onsurface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way (4 + 24), Double door |
| 112 | Supplyingand fixingof following ways surface/ recessmounting, vertical type, 415 V, TPN MOB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MOB TPDB is normally used where 3 phase outlets are required.)12 way (4 + 36), Double door |
| 113 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles intheexistingMOBDBcompletewithconnections,testingand commissioning etc. as required.Single pole |
| 114 | Supplying and fixing following rating, four pole, 415 V, isolator in the existingMOBDBcompletewithconnections,testingand commissioning etc. as required.40A |
| 115 | Supplying and fixing following rating, four pole, 415 V, isolator in the existingMOBDBcompletewithconnections,testingand commissioning etc. as required.63A |
| 116 | Supplying, installation, testing and commissioning of square/round type surface/recess Mounted LED light fitting with driver, power coated frame having luminous flux>= 1200 Im and luminous efficacy >=100 Im/w, suitable for operation of 240 Volts 50 Hz AC Supply, complete with all accessories directly on ceilling, including connection with 1.5 sqmm FRLS PVC insulated, copper conductor, single core cable earthing etc. as required. |
| 117 | Supplying, installation testing & commissioning of alluminum extruded channel finished housing with Plastic and cap LED Mirror light fitting with lamp having minium lumen out of >=900 lumen minimum luminous efficacy >=100 Lumen/ watt complete with frosted PMMA diffuser i/c all accessories complete etc as required. |
| 118 | Installation of Exhaust Fan in the existing opening, including making good the damage, connection, testing, commissioning etc as required/Upto 450 mm sweep |
| 119 | Supplying 250 mm sweep exhust fan (PVC) body) in the existing suitable size of the above fan etc as reqd. |
| 120 | Supplying and fixing of 400 mm sweep wall mounted cabin fan with built in step regulator suitable for operation on 230 V, 50 Hz A.C supply I/c connection etc. complete as required. |
| 121 | Supplying, Installation, Testing & commissioning of LED Foot lamp of 3 Module along with suitable size GI box and front plate mounting recess on wall including connection with 1.5 sq.mm FR LS PVC insulated, copper conductor, single core cable & earthing etc as required. |
| 122 | Supplying, installation, Testing Commissioning of vertical type storage type ABS (Plastic) body with incoloy heating element and glass line coating tank (BEE 5 star rating) water heater of 15 ltr capacity operating in 230 volts single phase complete with all modern safety devices like as thermostate, thermal cut out, pressure cum vacuum release valve, fuseable plug metal tank, working pressure 3-4 kg/sqmtrs (Max) with all acessories along with water pipe connection inlet and outlet pipe etc as required. |
| 123 | Supplying, installation, Testing and commissioning of split Air-conditioner with Rotary compressor ISEER (W/W): 5.20-BEE 5 star rating inverter type split AC units with inner groved coper piping, having swing rotary compressor suitable for indoor units to be ficed on the wall stand having suitable for single phase, should be robust enough to withstand power in range of 130V-285V, 50 Hz AC supply complete with outdoor unit, interconnection with copper tubing etc complete as required,/ 1.5 Tr (Btu-15000) 5 star standard Nominal cooling capacity full/Half (Min-max) (KW):5.28/2.64 (1.58-5.75), (inverter 5 star cooling only). High wall mounted split type unit. |
| 124 | Supplying , installation, testing and commissioning of automatic voltage stabilizer for air conditioner with 130-300 volts range for operation of air conditioner complete with testing trail run etc complete as reqd. |
| 125 | Supplying and drawing of PVC insulated copper conductor cable of 3 core 4 sq.mm size in existing PVC conduit i/c connection etc complete as required |
| 126 | Supplying & fixing of following size fefrigerant copper tube with Nitrile insulation cutting, welding, brazing i/c gas charging etc as required/ 1/4\"\" |
| 127 | Supplying & fixing of following size refrigerant copper tube with Nitrile insulation cutting, welding, brazing i/c gas charging etc as required/ 1/4\"\" |
| 128 | Supplying and fixing of following sizes of class 3 CPVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required/20 mm |
| 129 | Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement: 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail