Tender For Construction Of 03 Acrs (18×16) At Middle School Fremoh; 1 Earth work in excavation by mechanical means ( hydraulic excavator ) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil : 2 Supply and laying of dry stone soling hand packed incl. ramming 3 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) crushed 4 Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 5 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 6 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 7 Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 8 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more 9 Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete. 10 Centering and shuttering including strutting, propping etc. and removal of form for: Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. 11 Centering and shuttering including strutting, propping etc. and removal of form for: Edges of slabs and breaks in floors and walls Under 20 cm wide 12 Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platforms. 13 Centering and shuttering including strutting, propping etc. and removal of form for: Lintel, beams, plinth beams, girders, bressumers and cantilevers. 14 Centering and shuttering including strutting, propping etc. and removal of form for: Columns, pillars, piers, abutments, posts and struts 15 Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand) 16 Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level 17 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): ist class imported wood 18 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge.second Kail wood 30 mm 19 providing and fixing 4 mm thick glass pane (weighing not less than 10 kg/sqm) with all fixtures, all complete 20 Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of Rate for thickness of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm shutters for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : Second class kail wood 30 mm thick 21 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. second kail wood 22 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 23 P/F aluminium door bolts ISI marked anodised (anoidic coating not less than AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws complete job 300x16 mm 24 P/F of aluminium handles ISI marked as per IS 1868 transparent or dyed to reqd. colour with necessary Screws etc complete job 125 mm 25 P/F of aluminium handles ISI marked as per IS 1868 transparent or dyed to reqd. colour with necessary screws etc complete job 100 mm 26 P/F of aluminium tower bolts ISI marked as per IS 1868 transparent or dyed to reqd. colour with necessary screws etc complete job 150x10 mm 27 P/F of aluminium tower bolts ISI marked as per IS 1868 transparent or dyed to reqd. colour with necessary screws etc complete job 100x10 mm 28 Providing and fixing aluminum casement stays, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 29 Applying priming coat with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood). 30 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an even shade. Two or more coats on new work. On wood work 31 12 mm thick cement plaster of 1:4 mix (1 cement: 4 coarse sand) on walls. 32 Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1 mm thick, incl. applying one coat of water thinnable cement primer of approved brand and manufacture 33 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ liter of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats 34 Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) 35 Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick. 36 Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of 16mm required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour or shade (Area of slab over 0.5 sqm) 37 Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded 38 Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 39 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+/-5%) total coated thickness(TCT), Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws or with polymer coated Jor L. hooks, bolts and nuts and GI Seam bolts, and nuts, Gl plain and bitumen washerscomplete: Ridges and Valleys (Upto 60 Cm) wide 40 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse Sand aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete 41 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc. 42 Carriage of materialsfrom different leads to the site of work by machanical transport , Fine aggregate(Sand) for 38 Kms 43 Carriage of materialsfrom different leads to the site of work by machanical transport , Coarse aggregate(Bajiri) For 29 Kms 44 Carriage of materialsfrom different leads to the site of work by machanical transport , Bricks for 29 Kms 45 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. 46 Construction Of Kitchen at Middle school Fremoh Earth work in excavation by mechanical means ( hydraulic excavator ) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil : 47 Supply and laying of dry stone soling hand packed incl. ramming 48 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) crushed 49 Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 50 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 51 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 52 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more 53 Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete. 54 Centering and shuttering including strutting, propping etc. and removal of form for: Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. 55 Centering and shuttering including strutting, propping etc. and removal of form for: Edges of slabs and breaks in floors and walls Under 20 cm wide 56 Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platforms. 57 Centering and shuttering including strutting, propping etc. and removal of form for: Lintel, beams, plinth beams, girders, bressumers and cantilevers. 58 Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand) 59 Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level 60 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): ist class imported wood 61 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge.second Kail wood 30 mm 62 providing and fixing 4 mm thick glass pane (weighing not less than 10 kg/sqm) with all fixtures, all complete 63 Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of Rate for thickness of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm shutters for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : Second class kail wood 30 mm thick 64 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. second kail wood 65 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 66 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 67 P/F aluminium door bolts ISI marked anodised (anoidic coating not less than AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws complete job 300x16 mm 68 P/F of aluminium handles ISI marked as per IS 1868 transparent or dyed to reqd. colour with necessary Screws etc complete job 125 mm 69 P/F of aluminium handles ISI marked as per IS 1868 transparent or dyed to reqd. colour with necessary screws etc complete job 100 mm 70 P/F of aluminium tower bolts ISI marked as per IS 1868 transparent or dyed to reqd. colour with necessary screws etc complete job 150x10 mm 71 P/F of aluminium tower bolts ISI marked as per IS 1868 transparent or dyed to reqd. colour with necessary screws etc complete job 100x10 mm 72 Applying priming coat with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood). 73 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an even shade. Two or more coats on new work. On wood work 74 12 mm thick cement plaster of 1:4 mix (1 cement: 4 coarse sand) on walls. 75 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040mm bowl depth 250mm 76 Providing and Fixing of CP Angie Valve of Jaquar,Kerovit or of approved quality as per directions of Engineer Incharge.Complete job 77 Providing and fixing of bib cocks for bath rooms of Jaquar,Kerovit or of approved quality as per directions of Engineer Incharge. Complete job 78 Providing and fixing Pvc Water Storage tank of approved brand including Ball Cock with all necessary fittings and fixtures complete job 100 litre 79 Providing and fixingg Polyvinyl Chloride (PVC) pipes of approved make and brand including all fittings and fixtures complete job as per direction of Engineer-in-charge including trenching,refilling etc. 75 mm Dia 80 Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-in charge. Internal work-exposed on wall with clamps at 1.00 meter spacing. PN-16 pipe, 20mm OD(SDR-7.4) 81 Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-in charge. Internal work-exposed on wall with clamps at 1.00 meter spacing. PN-16 pipe, 32mm OD(SDR-7.4) 82 Providing and fixing brass stop cock of approved quality. 15 mm dia. nominal bore 83 Providing and fixing brass stop cock of approved quality. 20 mm dia. nominal bore 84 Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.(a) 15 mm nominal dia, (Jaquar or Equivalent as Per Make List) 85 Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1 mm thick, incl. applying one coat of water thinnable cement primer of approved brand and manufacture 86 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ liter of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats 87 Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick. 88 Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels (Area of slab over 0.5 sqm) Granite of any colour and shade 89 Structural steel work in built up sections, trusses and framed work including cutting hoisting fixing in position and applying a priming coat of approved steel primer all complete welded 90 Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shapewherever required 91 Providing and fixing precoated galvanised steel sheet roofingaccessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain and valleys (500 - 600mm) 92 Carraige of materials from different leads to the site of work by MT: FA for a lead of 38km 93 Carraige of materials from different leads to the site of work by MT: CA for a lead of 29km 94 Carraige of materials from different leads to the site of work by MT: Bricks for a lead of 29Km The estimated rates are exclusive of 18% GST. However the GST @18% shall be paid on gross amount excluding labour cess proportionately. Please Enable Macros to View BoQ information