Tender For Construction Work Of A Classroom And Verandah In Hukum Singh Inter College, Kaiserganj - Kaiserganj - Earth work in excavation by mechanical means (hydraulic excavator) maunal means over areas ( exceding 30 cm in dept, 1.5 mtr. In widht as well as 10 sqm on plan) including getting out and disposalof excavated earth lead upto 50 mtr. And for alllift as directed y engineer incharge all kind of soil.DSR-2.6.1 2 Excavating. Supplying, stacking and filling of local earth (including roylaty) by mechhanical transport upto a lead of 5 km. also including ramming and watering of the earth in layers notexceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complate for all lift.2.25A 3 Sand Filling-Supplyingandfillingin plinth with sandunderfloors, includingwatering,ramming,consolidatingand dressing complete.(DSR-2.27) 4 PCCProvidingandlayinginpositioncementconcreteof specifiedgradeexcludingthecostofcenteringand shuttering-Allworkuptoplinthlevel:1:4:8(1 Cement:4coarsesand(zone-III):8gradedstone aggregate 40 mm nominal size)(DSR-4.1.8) 5 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (cement : Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 6 Providingandlayinginpositionspecifiedgradeof reinforcedcementconcrete,excludingthecostof centering, shuttering, finishing and reinforcement - All work up to plinth level) 1:1.5:3(a) Footing 7 (b) Column 8 (c) Plinth 9 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands,plainwindow sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement:1.5coarse sand derived from naturalsources:3 graded stone aggregate20 mm nominal size derived from natural sources). (a) Lintel 10 (b) Slab 11 (c) Beam 12 (d) Column 13 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete . Thermo-Mechanically Treated bars of grade Fe-500D or more.(a) upto plinth 14 above plinth 15 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 16 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 17 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. (a) Providing & fixing of hold fast for chaukhatsof doors and windows. 18 Door / windows & Staircase grill. 19 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) 20 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 21 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 22 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm 23 Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm. D.S.R. 11.46.2 24 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -: 1:1.5:3 (1 cement : 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size) 25 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an evenshade Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 26 Finishing walls with Acrylic smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67ltr/10 sqm over the including base coat of water proofing cement paint applied @ 2.20 kg/10 Sqm. 27 One priming coat ofcement primer and twocoats oil distemper on new work including supply of all materials, labour and tools andplants etc. required for proper completion of the work 28 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. D.S.R. 13.80 29 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 30 Centering and shuttering including strutting, propping etc. and removal of form: in Foundations, footings, bases of columns, etc. for mass concrete 31 Centering and shuttering including strutting, propping etc. and removal of form in Suspended floors, roofs, landings, balconies and access platform 32 Centering and shuttering including strutting, propping etc. and removal of form in Lintels, beams, plinth beams, girders, bressumers and cantilevers 33 Centering and shuttering including strutting, propping etc. and removal of form in Columns, Pillars, Piers, Abutments, Posts and Struts 34 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter 35 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories forunplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermalexpansion. 110 mm bend 36 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cablein surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C 37 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 38 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 39 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.250 mm X 300 mm X 60 mm deep 40 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch 41 3 pin 5/6 A socket outlet 42 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.12 Module (200mmX150mm) 43 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 44 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 45 SUB HEAD (II) :- (NON SECHDULE ITEMS)Supply and fixing of hexagonal / round GP fan box of approved make made up 1.0 mm thick ISI marked GP sheet spot welded four to eight holes of 25.40 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.50 mm GP steel made upper and lower cover duly screwed fitted with 300 mm round zink coted MS bar x 12 mm and brand name should be embossed, fixing with wiring conduit laid in the R.C.C. roof before concreting along with supply of all material, labour, T&P etc. required for proper completion of work. 46 Supply and fixing of 20 Watt LED Metal body batten fitting suitable for both surface & suspended with 3 year warrantee , complete in all respect 47 S/F of Ceiling fan 1200 mm ISI marked complete 48 S/F of 9 watt LED Bulb ISI complete. 49 S/F Of Sign Board at site 50 deduction of competitive price efficincy @ 5%