Tender For Repair/ Replacement Of Fittings / Fixtures Other Than Hosp Bldg  At Ahrr  Under Ge E/M Rr Hosp Delhi Cantt-10;  1 Taking down carefully unserviceable of aluminium point wiring complete except for ceiling or where not feasible fan / plug / bell but including fittings such as switches, ceiling rose, pendants, regulator etc. and making good disturbed surface to match with the existing surface of roof / wall / floor by applying putty and applying colour / white wash finish complete all as specified and directed.  2 M & L for point wiring of concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into and including PVC conduit of suitable dia, complete with all conduit accessories, GI metal flush box of suitable for modular / conventional switches / sockets / fan regulators with cover plates, blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed for the followings :- Note - All accessories likes modular top cover plate / hylum sheet cover plate, Metal flush box, screws etc as applicable will be included in quoted rates,Point for One light/fan/bell/exhaust fan point controlled by one switch.  3 All as per item No. 2 above but for One 3 Pin socket outlet 5 Amps on Independent board.  4 All as per item No. 2 above but for One 3 Pin socket outlet 5 Amps on same board.  5 All as per item No. 2 above but for One light point controlled by two, two way switch  6 All as per srl item No. 2 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 15 Amp power point.  7 M & L for point wiring of concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing in existing conduit, GI metal flush box of suitable for modular / conventional switches / sockets / fan regulators with cover plates, blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed for the followings :- Note - All accessories likes modular top cover plate/ hylum sheet cover plate, Metal flush box, screws etc as applicable will be included in quoted rates. Point for One light/fan/bell/exhaust fan point controlled by one switch.  8 All as per srl item No.7 here-in-before butOne 3 Pin socket outlet 5 Amps on Independent board.  9 All as per srl item No.7 here-in-before butOne 3 Pin socket outlet 5 Amps on same board.  10 All as per srl item No.7 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 15 Amp power point.  11 M & L for point wiring of concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing in casing & caping, GI metal flush box of suitable for modular / conventional switches / sockets / fan regulators with cover plates, blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed for the followings :- Note - All accessories likes modular top cover plate/ hylum sheet cover plate, Metal flush box, screws etc as applicable will be included in quoted rates. Pont forOne light/fan/bell/exhaust fan point controlled by one switch.  12 All as per srl item No.11 here-in-before butOne 3 Pin socket outlet 5 Amps on Independent board.  13 All as per srl item No.11 here-in-before butOne 3 Pin socket outlet 5 Amps on same board.  14 All as per srl item No.11 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 15 Amp power point.  15 S & F in replacement of Modular Switch 16 Amp, 1 Module, single pole one way, ISI marked complete all as specified  16 S & F in replacement of Modular Socket 6 / 16 A - 2/3 Pin combined 2 module complete all as specified and directed  17 S & F in replacement of Modular Switch 1 way 6 /10 A, 1 Module complete all as specified and directed.  18 S & F in replacement of Modular Socket 6 / 10 A - 2 / 3 Pin combined 2 module complete all as specified and directed.  19 S & F in replacement of Modular Switch 2 way 6 / 10 A, 1 Module complete all as specified and directed.  20 S & F in replacement ofModular Bell push 6A 1 module , 240 Volts complete all as specified and directed.  21 S & F in replacement of Modular fan regulator, Step type, 2 Module Suitable for operation of BLDC fan, 240 V, complete all as specified and directed.  22 S & F in replacement ofCeiling rose surface Polycarbonate type with three terminals 240 Volts complete all as specified and directed.  23 S & F in replacement of Lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings, 240 Volts, complete all as specified and directed.  24 S & F in replacement ofBell Ding Dong, 240 Volts complete all as specified and directed.  25 Material and labour in replacement of Sub main wiring with 2 run of 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including PVC conduit of suitable size, complete with all PVC accessories and 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB / Panel to sub DB incl removing old sub main complete incl cutting chases etc all as specified and directed.Note :Cutting chases required for sub main wiring shall be finished with cement mortar 1:4 and surface shall be matched with existing shade of surface shall be deemed to be included in the unit rate quoted by the contractor.  26 Material and labour in replacement of Sub main wiring with 2 run of 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including PVC conduit of suitable size, complete with all PVC accessories and 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB / Panel to sub DB incl removing old sub main complete incl cutting chases etc all as specified and directed.Note :Cutting chases required for sub main wiring shall be finished with cement mortar 1:4 and surface shall be matched with existing shade of surface shall be deemed to be included in the unit rate quoted by the contractor.  27 Material and labour in replacement of Sub main wiring with 2 run of 2.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including PVC conduit of suitable size, complete with all PVC accessories and 2.5Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB / Panel to sub DB incl removing old sub main complete incl cutting chases etc all as specified and directed.Note : Cutting chases required for sub main wiring shall be finished with cement mortar 1:4 and surface shall be matched with existing shade of surface shall be deemed to be included in the unit rate quoted by the contractor.  28 Material and labour in replacement of Sub main wiring with 2 run of 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in existing PVC conduit or new casing & caping of suitable size, complete with all PVC accessories and 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB / Panel to sub DB complete fixing on surface / wall and removing old sub main complete all as specified and directed.  29 Material and labour in replacement of Sub main wiring with 2 run of 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in existing PVC conduit or new casing & caping of suitable size, complete with all PVC accessories and 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB / Panel to sub DB complete fixing on surface / wall and removing old sub main complete all as specified and directed.  30 Material and labour in replacement of Sub main wiring with 2 run of 2.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in existing PVC conduit or new casing & capingof suitable size, complete with all PVC accessories and 2.5Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB / Panel to sub DB complete fixing on surface / wall and removing old sub main complete all as specified and directed.  31 Material and labour in replacement of Sub main wiring with 4 run of 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including PVC conduit / casing & caping of suitable size, complete with all PVC accessories and 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB / Panel to sub DB complete fixing on surface / wall all as specified and directed.  32 Material and labour in replacement of Sub main wiring with 4 run of 10 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including PVC conduit / casing & caping of suitable size, complete with all PVC accessories and 10 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB / Panel to sub DB complete fixing on surface / wall all as specified and directed.  33 Supply and fix Modular AC Box with MCB (25A, SP) Protected Socket, with sheet steel enclosure including Top Pin of 25 A, with indicator complete all as specified and directed  34 S & F in Replacement Decorative Cover for MCB Box, made of durable photo frame and hard board, with weather-resistant sticker having high-quality adhesive backing.Natural design / photographs as decided by the department will be placed and sticker for bottom line shall be printed with customized bilingual content as follows, SERVING THE SAVIOURS, GE E/M RR HOSPITAL, DELHI CANTT-10, Save Electricity and Water – Every Watt Matters, Every Drop Counts, बिजली और पानी बचाएं – हर वाट की अहमियत है, हर बूंद की कीमत है, complete with mounting accessories and installation as per site conditions, final design to be approved by GE prior to printing, all as specified and directed for frame size of 12 x 12.  35 All as per item No 34 here-in-before but size 15 x 12  36 All as per item No 34 here-in-before but size 18 x 12  37 S & Fin repairs Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 12 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of RCCBs / MCBs and isolators etc and making all necessary connections complete all as directed.  38 S & Fin repairs Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of RCCBs / MCBs and isolators etc and making all necessary connections complete all as directed.  39 S & Fin repairs Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 4 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of RCCBs / MCBs and isolators etc and making all necessary connections complete all as directed.  40 S & Fin repairs Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, TPN 4 way, 415 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of RCCBs / MCBs and isolators etc and making all necessary connections complete all as directed.  41 S & Fin repairs MCB, SPN, 63 Amps capacity, 240V, B Curve type, 10kA, double pole with over load and short circuit protection complete all as specified and directed  42 S & Fin repairs MCB, TPN, 63 Amps capacity, 415 V, B Curve type, 10kA, with over load and short circuit protection complete all as specified and directed  43 S & Fin repairs MCB, SP, 40 to 63 Amps capacity, 240V, B Curve type, 10kA, single pole with over load and short circuit protection complete all as specified and directed  44 S & Fin repairs MCB, SP, 6 to 32 Amps capacity, 240V, B Curve type, 10kA, single pole with over load and short circuit protection complete all as specified and directed  45 S & F in repairs, Cubid Fan, made of ABS body, 2 x 2, Single Phase, AC, 50 Hz, 230V, having 400mm sweep blades, min air delivery 75 CMM, max RPM 1750, with LED lighting and having remote control etc complete all as specified and directed.  46 Supply and fix in replacement Ceiling recessed mounting LED luminaire,600 mm x 600 mm, (2 x2) 35/36 watt, luminaire should be made of single piece deep drawn CRCA housing with fully diffused PC/PS diffuser for general lighting in office areas.The LEDs used should have a colour consistency SDCM≤5, CRI ≥ 80 and CCT 6500K, ≥ 120 lumen/watt, PF ≥0.95, Surge Protection 3.5KV. The brand name shall be embossed / engraved on the luminaire / accessory / Endplate / Rim / Frame / end caps & not put using sticker / screen printing. The LED Luminaire & its driver both should be BIS registered & shall be of the same make/manufacturer as that of LED luminaires complete all as specified and directed.  47 All as per item Srl No 46 above but CCT 3000K  48 Supply and fix in replacement Surface / wall mounted LED batten 20 W, luminaire made up of Extruded Aluminium Housing with PC diffuser,IP 40.The LEDs used should have a colour consistency SDCM≤5, CRI ≥ 80 and CCT 6500K,≥ 120 lumen/watt, PF ≥0.95.The luminaire brand name shall be embossed / engraved on the luminaire / accessory / Endplate / Rim / Frame / end caps & not put using sticker / screen printing.The LED Luminaire & its driver both should be BIS registered & shall be of the same make / manufacturer as that of LED luminaires complete all as specified and directed  49 All as per item Srl No 48 above but CCT 3000K  50 All as per item Srl No 48 above but, 25 W and CCT 6500K  51 All as per item Srl No 48 above but, 25 W and CCT 3000K  52 All as per item Srl No 48 above but, 10 W and CCT 6500K  53 All as per item Srl No 48 above but, 10 W and CCT 3000K  54 S & F in replacement Surface mounted, Microwave Motion Sensor LED light fitting 15 watt, Round Type, 240V, AC, 50 Hz, has an inbuilt Microwave motion sensor to dim the LED in case of no movement (auto-dim on inactivity), as long as the motion is detected, the LED flush Light glows at full brightness and it dims in case of no movement for 3 min, with PC diffuser, IP20 from dust.CRI ≥ 80 and CCT 6500K, ≥ 110 lumen / watt, PF ≥0.90, surge protection of min 2.5KV.The luminaire brand name shall be embossed / engraved on the luminaire / accessory/ Endplate / Rim / Frame / end caps & not put using sticker / screen printing. The LED Luminaire & its driver both should be BIS registered & shall be of the same make / manufacturer as that of LED luminaires complete all as specified and directed.  55 All as per item Srl No 54 above but, CCT 4000K  56 All as per item Srl No 54 above but, 20 W, 6500 K  57 All as per item Srl No 54 above but, 20 W, 4000 K  58 S & F in replacement ceiling recessed mounting LED COB Lights, 15 W, with COB LED, flexible to suit for different applications, Aluminium housing for better thermal management.The LEDs used should have CCT 4000K, ≥ 110 lumen / watt,50,000 burning hrs, PF ≥0.95, Surge Protection 3.5KV. The LED Luminaire & its driver both should be BIS registered & shall be of the same make/manufacturer as that of LED luminaires complete all as specified and directed.  59 Supply and fix in replacement energy efficient wall mounted LED bulk head light fitting 10 / 12 watt, Outdoor IP 65, LED Bulkhead Light, CW 6500K , PF>0.95 and Voltage rated 220V to 240V etc complete all as specified.  60 Supply and fix in replacement PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to relevant IS, twin core, 0.50 sqmm size complete all as specified and directed  61 Supply and fix in replacement PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to relevant IS, twin core, 0.75 sqmm size complete all as specified and directed  62 Supply and fix in replacement PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to relevant IS, twin core, 1.00 sqmm size complete all as specified and directed  63 Supply and fix in replacement PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to relevant IS, 3 core, 1.50 sqmm size complete all as specified and directed  64 Supply and fix in replacement PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to relevant IS, 3 core, 2.50 sqmm size complete all as specified and directed  65 Supply and fix in replacement PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to relevant IS, 3 core, 4.00 sqmm size complete all as specified and directed  66 Supply and fix in replacement PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to relevant IS, 3 core, 6.00 sqmm size complete all as specified and directed  67 Supply and fix in replacement casing capping heavy duty double lock type of size 25 x 12 mm, ISI marked including all fixing accessories complete all as directed.  68 Supply and fix in replacement, non metallic rigid PVC conduit pipe medium grade 20 mm diaincluding accessories likes as tees, bends, elbows, reducers, bell mouth, tube ends, saddles, pipe hooks etc all as directed.  69 Supply and fix in replacement, non metallic rigid PVC conduit pipe medium grade 25 mm diaincluding accessories likes as tees, bends, elbows, reducers, bell mouth, tube ends, saddles, pipe hooks etc all as directed.  70 Supply and fix in replacement, capacitor of 2.5 mfd capacity all as directed.  71 Supply and fix in replacement, capacitor of 3.15 / 4.0 mfd capacity all as directed.  72 S&F in replacement Switch piano flush type, single pole, one way, 6 Amps complete all as specified and directed.  73 S&F in replacement socket piano type, two-in-one, 2 & 3 pin, 6 Amp universal type complete all as specified and directed.  74 S&F in replacement Switch piano type 15 / 16 Amp, single pole, one way type complete all as specified and directed.  75 S&F in replacement Socket piano type, two-in-one, 15 & 5 Amp, multipurpose shutter type complete all as specified and directed.  76 S&F in replacement electronic fan regulator, step type and making all necessary connections complete all as specified and directed.  77 S&F in replacement Bell push switch, single pole, one way, 5/6 Amps complete all as specified and directed.  78 S&F in replacement Switch socket combination 6 amps, 2-in-1 with PVC box, 240 volts, 50 Hz all as specified and directed.  79 S&F in replacement Switch socket combination 5 A & 15 A amps, shutter type with PVC box, 240 volts, 50 Hz all as specified and directed.  80 S&F in replacement 3 Pin Plug Top 5/6 amp complete all as directed.  81 S&F in replacement 3 Pin Plug Top 15/16 amp complete all as directed.  82 S&F in replacement 3 Pin Plug Top 25 amp complete all as directed.  83 Supply and fix in replacement, Service wire twin core, 4.0 sqmm aluminium, complete all as specified  84 Supply and fix in replacement, Service wire twin core, 6.0 sqmm aluminium, complete all as specified  85 Supply and fix in replacement, Service wire twin core, 10.0 sqmm aluminium, complete all as specified