| 1 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft and loose soil all as specified & directed by Engineer-in-Charge. |
| 2 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc.25cm thick each layer of soil complete all as specified and directed. |
| 3 | Removal excavated soil to a distance not exceeding 50 m and depositingwhere directed at a level not exceeding 1.5 mabove the starting point complete all as specified & directed. |
| 4 | Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified & directed. |
| 5 | 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base etc, finished even and rough complete all as specified and directed. |
| 6 | 100mm thick PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) as in hard standing etc, finished even and rough complete all as specified and directed. |
| 7 | Reinforced cement concrete(M-25, design mix)as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed (reinforcement shall be measured and paid for separately). |
| 8 | Reinforced cement concrete(M-25, design mix) as in coloumns, pillars etc complete all as specified and directed (reinforcement shall be measured and paid for separately). |
| 9 | Reinforced cement concrete(M-25, design mix)as in beams, cantilevers , bressumers,lintels over 1.5m span, all as specified and directed . (reinforcement shall be measured and paid for separately). |
| 10 | Reinforced cement concrete(M-25, design mix)as in slabs supported on walls, beams etc, shelves and the like complete all as specified and directed (reinforcement shall be measured and paid for separately). |
| 11 | Form Work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work, vertical or to batter to give rough finish to flat surfaces complete all as specified and directed. |
| 12 | Form work to sides of pillars, coloumns and similar items (square, rectangular or polygonal) including edges rough finished surface of concrete flat complete all as specified and directed. |
| 13 | Form work to sides and soffits of floor or roof beams, beam hanunchings, girders, shelves including supports, overhangs etc also splays between floors and beams etc rough finished surface of concrete flat complete all as specified and directed. |
| 14 | Form work to flat surfaces of suspended slabs such as roof slab, floor slab, landing, shelves etc not exceeding 200mm thick,including edges in any position, rough finished surfaces, complete all as specified and directed. |
| 15 | Form Work to edges of concrete flats, treads, break in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n.exc 20cm wide and side of RCC / PCC bends in walls , horizontal or sloping and similar work exc10cm but n.exc 20cm wide complete all as specified and directed. |
| 16 | Mild steel TMT bars 10mm dia & over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed by Engineer-in-Charge. |
| 17 | Mild steel TMT bars 5mm dia and over upto and including 10mm dia, cut to length, bent to shape required, including cranking, bendingspirally including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips as in stirrups, spacers and binders , complete all as specified and directed. |
| 18 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 19 | Brick work with sub class ‘B’ bricks of old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:4 complete all as specified & directed. |
| 20 | Brick work with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified & directed. |
| 21 | Taking down cement plaster from brick walls or concrete surfaces including raking out joints, hacking out for key, scrubbing down with water complete all as specified and directed and removing rubbish etc. complete all as specified and directed. |
| 22 | 15mm thick rendering in Cement and Sand mortar 1:6 over concrete /brick surfacesfinished even and smooth without using extra cement, complete all as specified & directed. |
| 23 | Rendering 15mm thick in Cement and Sand mortar 1:4 overfair faces of brick / concrete ,finished even and smooth without using extra cement, inclunding complete all as specified. |
| 24 | Rendering 15mm thick in Cement and Sand mortar 1:4 overfair faces of brick / concrete ,finished even and smooth without using extra cement, inclunding using water proofing compound complete all as specified.Note : WPC shall be measured and paid separately. |
| 25 | Rendering 10mm thick in CM 1:3on fair faces of concrete/brick surfaces as in ceiling, chajja, facia or similar positions , finished fair and smooth complete all as specified and directed. |
| 26 | Supply only integral water proofing compound (ISI Marked) complete all as specified & directed. |
| 27 | Three coats of white wash on ceiling surfaces including preparation of new plastered surfaces complete all as specified and directed |
| 28 | One coat of white wash on wall surfaces including preparation of old surfaces complete all as specified. |
| 29 | Preparation of new plastered or un-plastered surfaces of walls and applying two coats of cement base paint, over a coat of primer complete all as specified and directed. |
| 30 | Preparation of old plastered surfaces of walls and applying two coats of cement base paint, over a coat of primer complete all as specified and directed. |
| 31 | Preparation of new surfacs and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and directed. |
| 32 | Preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed. |
| 33 | Preparation of old decorated wall surfaces and applying two coats of oil bound distemper complete all as specified and directed. |
| 34 | Preparation of old plastered surfaces of walls and applying two coats of oil bound distemper and applying wall care putty not lessthan 2mm thick on walls including preparation of surfaces complete all as specified and directed. |
| 35 | Preparation of old plastered surfaces of walls and applying wall care putty not lessthan 2mm thick includinga coat of alkali resistant primer on wall surfaces & smoothening the surfaces with sand papers etc andapplying 2 coats ofplastic emulsion paint complete all as specified and directed |
| 36 | Hard core ofbroken stone or boulders of gauge exc 63mm but n.exc 100mm, deposited, spread and leveled in layers n.exc. 15cm thick, watered and rolled / rammed to a true surface complete all as specified & directed. |
| 37 | Soil filling under floors or infoundations including watering and consolidationcomplete all as specified and directed. |
| 38 | 25mm thick Plain cement concrete 1:2:4 type B-0using 12.5mm graded crushed stone aggregate as in sub base complete all as specified & directed. |
| 39 | Kota Stone Slab flooring, 20-22mm thick, best quality over and including cement screed bed 15mm thick in cement mortar 1:6, laid and jointed with grey cement slurry and pointed with grey cement mixed with pigment to match the shade of the slab including cutting, rubbing, grinding and polishing (Mirror finish) complete all as specified and directed. |
| 40 | All as per serial item No 39 hereinbefore but on skirting / vertical surfaces laid over and including 10mm screed layer in cement mortar 1:3, cutting, rubbing, grinding and polishing complete, all as specified. |
| 41 | Steel window, box type, primer coated, 1.00mm wall thickness, with glazing bar and openable shutter prepared to recieve sheet glass, complete including cutting holes, four Nos. for each window and making good dismantled portion in PCC (1:2:4) type B-1. including following fittings welded to frame/ shutter complete all as specified and directed.:-(a) Hold fast 150mm out of 25x6mm flat iron made to shape- 04 Nos. each window (02Nos. on each side).(b) Handle of \"Z\" section 20mmx25mm, 100mm long- 01No. each leaf.(c) MS tower bolt 150mm long- 02 Nos. each leaf.(d) \"Z\" section 20mmx25mm, 100mm long stopper 01 No. each leaf. (e) Cleat 55mm long of hollow square section 15mmx15mm of 24 guage wall thickness, welded to hinge of 55mm size 01 No. per leaf.(f) MS box type hinges of 75 mm size- 02Nos. per leaf.(g) Fabrication & fixing complete.Note: Glass panes & painting shall be measured & paid separately under respective item.s. Design shall be approved from Engr-in-Charge as existing at site and all as per Drawingbefore fabrication and bulk order to the manufacturer. |
| 42 | All as per serial item No 41 hereinbefore but without glazing bar. |
| 43 | Framed work such as Gates, grills, gratings, etc with ends of bars shouldered and / or riverted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, raillings, frame work of water tanks and similar work confirming to Fe-290 grade E-165, complete all as specified & directed by Engineer-in-charge. |
| 44 | All as per serial item No 43 hereinbefore but for ornamental and intricate design |
| 45 | Mild steel framed work as in doors or gates of angles or other sections with gusset plates complete drilled for fixing of steel sheeting or other covering.Doors etc to be prepared for hanging or sliding with including hooks and hinges (excluding of covering steel sheeting) fastening, locking arrangement, etc conforming to Fe-410-O or Fe-310-O all as specified and directed. |
| 46 | Dismantling structural steel work of any description not otherwise provided for, all as directed. |
| 47 | Factory made pressed steel frames of profile width 125mm x 60mm fabricated from 1.25 mm thick sheet, for doors with one or more rebate including necessary fixing lugs, hinges, lock strike plate, etc. & one shop coat of primer, including PCC 1:3:6 complete all as specified and directed. |
| 48 | 35mm thick flush shutters, solid core construction, with block board core & plywood face panels, commercial type on both sides all as specified & directed by Engineer-in-charge. |
| 49 | 4mm thick sheet glass ordinary quality any size and in any type of frame and glazing with oil putty (or beading)in square n.exc 0.5 Square Metre in each pane,complete all as specified and directed. |
| 50 | Stainlesssteel wire cloth 0.36 mm nominal dia of wire & avg width of aperture 1.40 mm in fixed with tinned tacks,complete all as specified and directed. |
| 51 | Butt hinges (ISI marked) 100mm size, of extruded aluminum alloy with galvanisedmild steel hinge pin, anodised, type C-21, complete all as specified and directed. |
| 52 | 150 mm aluminium handles cast type anodized complete all as specified and directed. |
| 53 | 150 mm size aluminium , barrel tower bolt of extruded section and fixed complete all as specified and directed. |
| 54 | 300 mm longAluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed,complete all as specified and directed. |
| 55 | Preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 56 | Preparation of new steel surface of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide primer complete all as specified & directed by Engineer-in-charge. |
| 57 | Plain cement mortar 1:3:6 (type C-2 using 40mm graded aggregate), 75mm thick as in Plinth protection , finishing cement concrete even and smooth without using extra cement,all as specified. |
| 58 | Wire brushing and cleaning top surface of tiles, lime terracing or cement concrete, including flashings and junction of parapets, etc., and surface painting, with a layer of blown grade bitumen of any penetration applied hot @ 1.7 kg per sqm, blinded with grit or pea size gravel @ 0.006 cu.m per sq.m, and lightly tampered (area of flashings, etc., shall be added to the roof area) complete all as specified and directed. |
| 59 | 3mm thick Atactic polypropylene polymer (APP) based polymeric membrane minimum weighing 3.6kg/sqm andreinforced with polyester non woven fabric (weight not less than 150 gms/sqm) laid over a coat of oil bound bitumen primer @0.40L/Sqm by same membrane manufacturer of density 0.87 to 0.89 kg/L at 25° C temperature and viscosity 70 to 160 CPS. The membrane shall be laid using butane torch and sealing all joints etc having 75mm side lap joint and 100m end lap joint after preparing the surface as per standard practice and as per manufacturer instructions complete all as specified & directed. |
| 60 | Providing precast cement concrete 40mm thick RCC Jallies in (1:2:4) type B-0 using 12.5mm graded crushed stone aggregate,(measured solid), including all mouldings but excluding frame set in cement mortar 1:4 Complete all as specified and directed. |
| 61 | Demolition of reinforced cement concrete in roofs, floors, beams, staircases, landing, chajjas and similar suspended work, complete all as specified and directed. |
| 62 | Steel work in tubular trusses and tubular posts including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 t complete all as specified & directed by Engineer-in-Charge |
| 63 | Cement concrete type B-1, 1:2:4 using (20 mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including the use of forms or moulds with plain faces complete all as specified and directed. (Cement concrete item shall be reinforced, where ordered. Reinforcement shall be measured and paid separately). |
| 64 | Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 65 | Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge, complete all as specified and directed. |
| 66 | Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge. |
| 67 | Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) ofpproved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin-charge. |
| 68 | 5.5mm thick ordinary quality sheet glass,fixed to aluminum frame workin panels n. exc 0.5 Sqm in each pane, complete all as specified & directed. |
| 69 | 5.5mm thick ordinary quality sheet glass,fixed to aluminum frame workin panels exc 0.5 Sqm in each pane, complete all as specified & directed. |
| 70 | 4mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed. |
| 71 | Granite slab 16 to 18mm thick(of any type & shade as approved), as on cooking platform, counter slabetc (length and width as ordered by GE in one piece) best quality machine cut and jointed with grey cement slurry and pointed in white cement mixed with pigment to match the shade of slab laid over and including 15mm thick screed bed in cement mortar 1:4 including nosing at edges, rounded edges complete all as specified and directed. |
| 72 | 5mm thick aluminium composite panel sheet (ACP) fixed with aluminium beading with aluminum beading or steel framed work & stainless steel screws including all necessary clips and fittings colour as approved byEngr-in-Charge all as specified and directed. |
| 73 | Surface excavation not exceeding 30 cms deep and averaging 15cms deep and getting out in any type of soil, complete all as specified. |
| 74 | Concrete interlocking paver block, with grey cement and pigment, design as approved, any shape and size conforming to IS 15658-2006 of 80 mm thickness, M-40 Grade,complete all as specified and directed |
| 75 | Sand filling under floor or in foundation including watering and consolidation complete all as specified and directed. |
| 76 | Excavation in post holes (or similar hole) each in hard & dense soil n.exc 0.50 cu m getting out, returning, filling and ramming earth or broken rubble mixed with earth around, in layers not exc 25 cm, watering and removing surplus spoil at a distance not exc 50 metre and making good surfaces complete all as specified and directed. |
| 77 | Plain cement concrete 1:2:4 type B-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified & directed. |
| 78 | Dismantling floor hearth or wall tiling including cementmortar bedding (but not backing) removing serviveable tiles to store and rubbish off the premises complete all as specified and directed |
| 79 | Glazed coloured ceramic tiles in vertical surface 300mm x 450mm x 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 10mm thick rendering in cement mortar 1:4, complete all as specified and directed. |
| 80 | Non skid, first quality ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area or each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 81 | Non skid, first quality ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area or each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 82 | Taking down chowkhats or framen.exc 1.5 Sqm with shutter (without taking off shutters from the frame) and removal from site complete all as specified & directed. |
| 83 | Taking down chowkats or frame exc. 1.5 Sqm and n exc 4 Square metre with shutters, without taking off shutters from the frame,complete all as specified and directed. |
| 84 | Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). |
| 85 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-in- Charge |
| 86 | Steel water tubes, 15mm dia bore, medium grade, galvanized, with and including all fittings and fixed complete to walls ceiling or laid in floors, Taking up down steel tubing and connections 15mm bore complete all as specified and directed. |
| 87 | Steel water tubes, 20mm dia bore, medium grade, galvanized, with and including all fittings and fixed complete to walls ceiling or laid in floors, Taking up down steel tuibing and connections 15mm bore complete all as specified and directed. |
| 88 | Steel water tubes, 20mm dia bore, medium grade, galvanized, with and including all fittings and fixed complete to walls ceiling or laid in floors,complete all as specified and directed. |
| 89 | Gate valve 20mm bore screwed both ends for ion pipe complete all as specified and directed. |
| 90 | Cuttingchases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of inserting sheets, landings, steps, cills, sunshades, shelves, lintels, etc,; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth complete all as specified and as directed. |
| 91 | Vitreous china, wash down water closet pan, superior white, Pedestal pattern WC with ‘P’ or ‘S’ trap, seat cover (excluding, flushing cistern and flush pipe),fixed as in repair complete all as specified and directed. |
| 92 | Vitreous china, wash down water closet pan, superior white, Pedestal pattern WC with ‘P’ or ‘S’ trap, seat cover, (excluding, flushing cistern and flush pipe),fixed as in repair complete all as specified and directed. |
| 93 | Vitreous china squatting pan \"orissa\" pattern,size 580 x 440 mm white, with integral foot rest (excluding flushing cistern and flush pipe) including makes connection to trap & flushing pipe, set in cement concreteand making good to the floor, fixed as in repair complete all as specified & directed by Engineer-in-charge. |
| 94 | PVC valve less syphonic action type flushing cistern low level white with PVC in let ball valve, float and handle, 10 ltrs capacity and connection to pipes including PVC connection with PTMT nuts and 32mm dia CP flush pipe (long type for squatting pan), fixed as in repair, complete all as specified & directed. |
| 95 | Counter top wash basin, of Size 560x 470x190mm, oval shape, white colour, including waste pipe, CP angle valve, CP waste coupling etc fixed in position,fixed as in repair complete all as specified and directed. |
| 96 | Central hole Basin Mixer, with popup waste system with 450mm long copper pipes and brass nuts, cast copper alloy, chromium plated, screwed for iron pipe or for union, suitable for 15mm bore pipe, fixed as in repair complete all as specified and directed. |
| 97 | 15mm bore pillar tap, fancy type,cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe,fixed as in repair complete all as specified and directed. |
| 98 | Bib taps brass, fancy type,with wall flange, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule, suitable for 15mm bore pipe, fixed as in repair complete all as specified and directed. |
| 99 | Angular stop cock, fancy type, cast copper alloy chromium plated, screwed down,screwed both and for iron pipe or for union, suitable for 15mm bore pipe, fixed as in repair complete all as specified and directed. |
| 100 | PVC(SWR) pipe, 75mm bore, single socketed in any length with rubber ring joints, having minimum density 6 Kg/cm2 fixed to walls with MS clamps made out of flat ironincluding nuts bolts etc, fixed as in repair complete all as specified and directed. |
| 101 | PVC (SWR) bends any radius 75mm dia with oval acess door, fixed as in repair complete all as directed. |
| 102 | 75mm borePVC (SWR) junction single, (Single T/ Y) equal or unequal, with access door fixed as in repair complete all as specified and directed. |
| 103 | PVC(SWR) pipe, 110mm bore, single socketed in any length with rubber ring joints, having minimum density 6 Kg/cm2 oints ,laid in trenches or in foors, fixed as in repaircomplete all as specified and directed. |
| 104 | 110mm bore PVC (SWR) bends any radius, fixed as in repair complete all as specified and directed |
| 105 | 110mm borePVC (SWR) junction single, (Single T/ Y) equal or unequal, with access door fixed as in repair complete all as specified and directed. |
| 106 | PVC (SWR) floor trap 75mm bore, plain with grating incl jointing with solvent cement, in cement concrete type B-1 (1:2:4), fixed as in repair complete all as specified and directed. |
| 107 | Demolition of stone slabs and tiles of any description or thicknessin floors laid, bedded and pointed in any mortar complete all as specified and directed. |
| 108 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) With Semi preforated 12mm thick micro tegular edged GRG false ceiling tiles, false ceiling tiles of size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2% humidity resistance of 99% NRO .05 to 0.75 as per IS 8225:1987, Non-combustible as per BS 476 (part4)- 1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides ) comprising of main- T runners of size 15 x32 mm of length 3000mm, cross-T of sixe 15 x 32 mm of length 1200mm and secondary intermediate Cross-T of size 15 x 32mm of length 600mm to from grid module of size 600 x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mmlength and L-shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm centre to centre and 40mm long dry wall wood screws. The work shall be carried out asper specifications, drawing and as per direction of the Engineer-in-Charge. |
| 109 | Beveled edge looking mirror, 5mm thick of selected quality glass, providing hole as per required corner and centre, fixed with 3 inch screw and rawl plug including good quality SS cap (on screw head), complete all as specified and directed. |
| 110 | Demolition of cement concrete (un-reinforced) in ground floor and paving n.exc 15cm thickness (below or above GL) as in plinth protection/ path/ Hard standing/ floor etc. etc complete removal of debris outside MD land. |
| 111 | Plain cement concrete 1:5:10 type E-2 using 40mm graded brick coarse aggregate as in sunken floor filling and mass concrete complete all as specified & directed. |
| 112 | Water proofing treatment toSUNKEN PORTION incl bottom floors and adjoining walls of WC, Bath & Toilet, etc. : Preparation :- Concrete surface to be cleaned properly from dust, loose particles, and any type of roots of trees, algae or fungal growth.Repairing :- Surface irregularities, damaged concrete and surface cracks, if any with latex polymer , SBR latex or equivalent modified repair mortar incl all M&L .The surface then shall be primed using high pressure water jet or other method properly pre wetted to SSD condition before coating.NOTE :- Required minimum pull off strength is 1.5 N/mm2 (a) Priming coat :- Applying one coat of Synthetic Rubber Emulsion based cementitious coating system, using brush. Latex polymer to be added with OPC cement with water dilution as per data sheet.Consumption of misture :- 0.3 Kg/sqmSystem requirement Density - 1.02 Kg/LtrPH :- 6-8Main Water Proofing :- To be carried out after 2 hrs of applying primerProviding and applying Two coats of Acrylic Polymer modified cementitious Liquid water proofing compound System Structure :- Base Coat :- Two part Acrylic Polymer modified cementitious compoundConsumption base coat :- 1.5 Kg/sqmFibre Reinforcement Consumption :- 1 Sqm/SqmTop Coat :- Two part Acrylic Polymer modified cementitious compoundConsumption base coat :- 1.5 Kg/sqmLayer Thickness :- 1.5 mm avg thickness with Fibre meshSystem Requiremnets :-Mixed Density :- 2.0 Kg/Ltr at 27 degreeCompressive Strength :- >= 20N/mm2 in 28 days as per ASTM C109Bond Strength :- >= 2N/mm2 (Concrete Failure) as per ASTM C882SGS Certificate Free from acute lethal toxicity as per IS 6582CFTRI approved certificate (c) Ponding the sunken portion with water for 72 Hrs , after 3 hrs of final coating Protection Plaster :- 20 mm Thick Protection plaster in cement mortar (1:3) mixed with WP compound as per manufacturer’s instructionsshall be provided on treated sunken portion for even & smooth finish. |
| 113 | Cast copper alloy, chromium plated towel rail 600mm long, complete all as specified and directed. |
| 114 | Stainless steel grating 127mm dia complete all as specified and directed, |
| 115 | Vitreous China half stall urinal, fixed against wall in cement mortar (1:2),securing urinal with and including 60mm long brass screws, pointing around urinal back in cement, including CP waste coupling, 32mm PVC waste pipe, fixed as in repair complete all as specified and directed. |
| 116 | CP bottle trap dia of discharge pipe 40mm having minimum water seal of 25mm complete all as specified and directed. |
| 117 | 15mm bore brass CP urinal valve auto closing system (push cock) with built in contraol & wall flange all as specified and directed. |
| 118 | Brass CP Urinal spreader suitable for 15mm bore pipe,complete all as specified & directed. |
| 119 | 1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) double layered hoisted and fixed in position, including PTMT tank nipple, PTMT float valve of 20 mm bore etc, fixed as in repairs complete all as specified and directed. |
| 120 | Excavation over areas in hard/dense soil not exceeding 1.50 metre in depth and getting out complete, all as specified. |
| 121 | Excavation over areas in hard/dense soil exceeding 1.5 metre but not exceeding 3.00 metre in depth and getting out complete, all as specified. |
| 122 | Factory made RCC man hole covers, (Medium duty, M-35 Grade) of size 600mm x 600mm x 75mm with plain faces, including MS frame, set in position in cement mortar 1:4 complete all as specified and directed. |
| 123 | Factory made precast rubber moulded coloured chequered cement concrete tiles, superior quality 300mm x 300mm x 22-25mm thick , set, jointed and pointed in neat cement slurry with grey cement and pigment to match the colour of tiles, laid over and including 15mm thick screed bed in cement mortar 1:6, complete all as specified and directed. |
| 124 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 125 | Preparation of new decorated concrete or plastered surface exc 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of primer complete all as specified and directed. |
| 126 | One coat of white wash on ceiling surfaces including preparation of old surfaces complete all as specified. |
| 127 | Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect, complete all as specified and directed. |
| 128 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 129 | Material and labour forpoint wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single coremulti stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising ofOne light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note : Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original and nothing extra shall be paid on this account.Note :Unit rate is inclusive of cutting chases in wall /foor/PCC and making good the disturbed surfaces to match the original and nothing extra shall be paid on this account. |
| 130 | All as per serial item 129 herein before but for socket outlet 3 pin 6Amps on same board complete all as specified and directed |
| 131 | All as per serial item 129 herein before but for socket outlet 3 pin 6 Amps on independentboard complete all as specified and directed |
| 132 | All as per serial item 129 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSHcable & 2.5 Sqmm (nominal area) cable as earth continuity conductor |
| 133 | Switch modular type (ISI marked), single pole, one way 6 Amps, one module(ISI marked), complete all as specified & directed. |
| 134 | Switch modular type (ISI marked), single pole, one way 16 Amps, one module(ISI marked), complete all as specified & directed. |
| 135 | Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose two module (ISI marked), complete all as specified & directed. |
| 136 | Socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed. |
| 137 | Modular switch type stepped fan regulator, single pole, 230 volt two module complete all as specified and directed. |
| 138 | Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specifiedand directed by Engineer-in-charge. |
| 139 | Lamp holder, PVC/Polycarbonate type with back plate modular type fixed on wall suitable for batten fitting ,complete all as specified and directed. |
| 140 | LED lamp9 watts, B-22 type complete all as specified . |
| 141 | Disconnecting the power supplyand taking down carefully by unscrewing from boards fittings and fixtures such as DBs, Junction Box, Panels of any size complete with all MCCB\"s ,MCB\"s etcand removing from site, Complete all as specified and directed . |
| 142 | MCCB, 125 Amps, four pole, 3 phase , 16KA, 415 volt with adjustable thermal andmaganetic release, with proper thimble complete all as specified and directed |
| 143 | Vertical TPN distribution board double door flush mounting with provisions for MCCBs incomer upto 125 Amps & outgoing 4 way having IP 43 protection Complete all as specified and directed . |
| 144 | MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 08 way SPN with 200 Amps busbar 240V completed all as specified and directed. |
| 145 | MCB ,SP , 240 volt, 6Amps to 32Amps, 10 KA , \"C\" series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 146 | MCB, SP, 240 volt,40 to 63Amps, 10 KA , \"C\" series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 147 | Single pole and neutral enclosure with a two pin and earth plug and socket complete with one SPN 32 Amp MCB complete all as speicified and directed. |
| 148 | Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and provision of flexible copper cable 3 core from ceiling rose tofan complete all as specified and directed. |
| 149 | LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, fixed as in repair complete all as specified and directed. |
| 150 | LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete fixed as in repair complete all as specified and directed. |
| 151 | LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size fixed as in repair complete all as specified and directed. |
| 152 | Taking down carefully old copper or aluminium sub main wiring of any Nos of wiring and size with earth wire on wooden batten/ surface conduit/ casing- capping complete with its all accessories and making good disturbed surfaces of wall , floors etc complete all as specified and directed. |
| 153 | Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 4 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 4 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. |
| 154 | Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 6 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 6 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.NOTE FOR SERIAL ITEM NO 153 & 154:(i)Two runs of cable, one run of earth wireshall be considered as one running metre(ii) Cutting chases will be measured and paid separtely(iii) colour code shall be Red for phase, Black for neutral and green for earth |
| 155 | Supply and fixing sub main wiring with Four singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.Note : (i)Four runs of cable, one run of earth wireshall be considered as one running metre(ii)Cutting chases will be measured and paid separtely(iii) colour code shall be Red for phase, Black for neutral and green for earth |
| 156 | Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete including dismantling of old earthing, all as specified and directed. Note(s) :-(i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.(ii)PCC chamber shall be constructed 500 mm away from the edge of earth pit.(iii) Rate shall include earth lead and protection pipe of length 7.5m(iv)Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt.(v) unit rate including protection pipe and GI wire 4.00mm dia from top to earth plate upto 7.5 meter |
| 157 | LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver,includinglamp bracket upto 1.5metre length as per suitable for fitting including clamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, including taking down old street lght complete all as specified and directed. |
| 158 | LED panel recess mounted ultra slim 2\"x2\" - 36 wattsultra slim (cool day) ceiling light, aluminum extruded housing with milky diffuser, heat exchanger unit, LED driver, surge protection complete suitable for perfect lighting cutting hole of required size in POP/false ceiling making good disturbed including taking down any type ceiling fittingcomplee all as specified and directed. |
| 159 | Exhaust fan energy efficient metallic blades heavy duty turbo force of size 450mm sweep, 1400 rpm, AC 230 volts complete with louvers shutters mounting on wall with holding down bolts, nuts, washerscomplete all as specified and directed. |
| 160 | Cutting openings, through brick walls in round shape , for 450mm dia exhaust fan and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required including finishing and matching the disturbed surface and removing surplus unserviceable bricks, hard-core, etc..from site and rubbish complete all as specified & directed by Engineer-in-charge. |
| 161 | Electric water heater(vertical type geyser), capacity 25 litre, 2 KW BEE 5 Star rated AC single phase, including MS glass lined inner tank, glass coated heating element, high density PUF insulation, Anode rod protection, heavy duty fastner not less than 100mm with suitable size of nut & washer grouted in wall with complete mason work for proper mounting of geyser fastner bolts with all accessories such as safety valve, thermostat, NRV, connection piece etc. making necessary inlet / outlet water connection, testing on load including provison of 15 Amp plug top and PVC insulated & PVC sheathed copper conductorcable 4 sqmm 3 core upto 15 Amp plug point and inlet and outlet copper connection complete all as specified and directed. |
| 162 | Air circulator heavy duty fan 600mm sweep, 230 volt single phase oscillatingsuitabe for wall mounting, 1380 RPMand provision of flexible copper cable 3 core from ceiling rose tofan complete all as specified and directed. |
| 163 | XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm, 4 core, laid in trenches , sleeving through pipes of fixed on poles & wall or laid under floors inlcuding jointing with suitable size of alumunium lugs as specified and directed. |
| 164 | 50mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS 14930 Part-II with anti rodent and non flame propogating properties of approved colour with fittings for cable protection from approval make complete , all as specified and directed |