Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | EXCAVATION & EARTHWORK |
| 2 | Excavation in trenchesnot exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc. not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed |
| 3 | Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed |
| 4 | Removing excavated materialsto a distancen ot exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed |
| 5 | Excavating in post holes (or similar holes) each not exceeding 0.5cum, returning, filling in, getting out in soft / loose soil and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm and removing surplus soil to a distance not exceeding 50m complete all as specified and as directed |
| 6 | B/R WORKS |
| 7 | M&L for dismantling rusted / damaged fencing of any size / type from any height and disposing off complete all as specified and as directed |
| 8 | Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground complete all as specified and as directed |
| 9 | Dismantling mild steel work or wraught iron of any description and in any position complete all as specified and as directed |
| 10 | Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) and removal of debris complete all as specified and as directed |
| 11 | Dismantling asbestos cement (corrugated/semi corrugated) in roof coverings, etc including ridges, claddings, etc. including all necessary staging / scaffolding, etc. as required and disposing off complete all as specified and as directed |
| 12 | Dismantling wooden boarding (eaves board, rafter, etc.) of any description fixed in any position with nails complete all as specified and as directed |
| 13 | Dismantling wall and ceiling boards (fibre,pulp, insulation, etc. or insulation boards/slabs/blankets, any thickness including cover fillets, frameworks, etc. complete all as specified and as directed |
| 14 | Demolition of concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed |
| 15 | Taking down cement or cement/lime plaster,any description on brick or stone walls, etc. including raking out joints, hacking for keys, scubbing down with water, etc. including all necessary scaffolding as required and rubbishing off the premises, etc. complete all as specified and as directed |
| 16 | Taking down chowkats or frames not exceeding 1.5sqm each with shutters (without taking off shutters from the frame), disposing off and making good the disturbed areas, portions and surfaces |
| 17 | Taking down chowkats or frames exceeding 1.5sqm but not exceeding 4.0sqm each with shutters (without taking off shutters from the frame), disposing off and making good the disturbed areas, portions and surfaces |
| 18 | Taking up or down 15mm bore steel water tubing and connections from any location / position including sorting, stacking, cleaning serviceable pipes and disposing off other, etc. complete all as specified and as directed |
| 19 | Taking up or down 20mm bore steel water tubing and connections from any location / position including sorting, stacking, cleaning serviceable pipes and disposing off other, etc. complete all as specified and as directed |
| 20 | Dismantling asbestos cement / PVC pipe 50/75/100mm dia including clamps from any position or any location and disposing off complete all as specified and as directed |
| 21 | Cutting chases, pinning in brick walls and making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cuttingexceeding 20cm in girth complete all as specified and as directed |
| 22 | Cutting chases, pinning in brick walls and making good to facings where required and pointing in cement mortar 1:3 and making good, cuttingexceeding 10cm in girth complete all as specified and as directed |
| 23 | S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar works conforming to Fe-290 grade E-165 complete all as specified and as directed |
| 24 | S&F bands, straps, hold fasts, wall ties, cleats, supports or stays of RWPs, ventilation pipes and similar articles of mild steel conforming to Fe-290 grade E-165 including bolts as required complete all as specified and as directed |
| 25 | S&F in position steel work in trusses, purlins, posts and the like using tubular/ square hollow sections including special shaped washer, etc. using ERW or induction butt welded tubes / SHS conforming to IS-1161-2014 / IS-4923-1997 grade St-240 complete all as specified and as directed |
| 26 | S&F screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed at both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5cm in length, dia of neck & shank 11 to 15mm complete all as specified and as directed |
| 27 | M&L framed work as in steel gate frmaed and side hung including pintle hinges, stops, hand made sliding bolt monkey tsil bolts etc., complete all as specified and as directed |
| 28 | S&F mild steel angle iron posts & struts in fencing including cutting top to shape,drilling holes, notching for wire including all necessary drilling bolts or rivetting & similar works conforming to Fe-290 grade E-165 for securing chain link fencing, etc. complete all as specified and as directed |
| 29 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed |
| 30 | M&L for mild steel TMT bars grade Fe-500D, 8mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed |
| 31 | M&L for mild steel TMT bars grade Fe-500D, 5mm dia and over upto 10mm dia, as in stirrups, spacers, etc. cut to length, bent to shape required including cranking, bending spirally for hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed |
| 32 | M&L for use and waste formwork to sides of concrete foundations, bases of columns, rafts, raft beams, plinth beams and similar works, vertical or to batter, for rough finished flat surfaces of concrete complete all as specified and as directed |
| 33 | M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces complete all as specified and as directed |
| 34 | M&L for brickwork with sub-class \"B\" bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and as directed |
| 35 | M&L for brickwork with sub-class \"B\" bricks, straight or curved on plan to any radius as in half brick thick walls built in CM (1:4) complete all as specified and as directed |
| 36 | M&L for providing RCC (nominal mix) 1:1.5:3 type A1 using 20mm graded aggregates as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, basement slabs, under-reamed piles, mass concrete, etc. complete all as specified and as directed |
| 37 | M&L for providing RCC (nominal mix) 1:1.5:3 type A1 using 20mm graded aggregates as in columns, posts, piers, pillars, struts, etc. complete all as specified and as directed |
| 38 | M&L for cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregates) in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed |
| 39 | M&L for plain cement concrete type B-0, 1:2:4 (using 12.5mm gradedstone aggregates) as in haunching roof kerbs, levelling courses, etc. complete all as specified and as directed |
| 40 | M&L for 40mm thick plain cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregates) as in roof padding, haunching, roof kerb or similar works including applying 3kg/sqm neat cement slurry complete all as specified and as directed. |
| 41 | M&L for cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregates) as in foundation, filling and mass concrete ,complete all as specified and as directed |
| 42 | M&L for cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregates) as in bed blocks, back filling of steel frame and holdfasts, etc. including necessary formwork complete all as specified and as directed |
| 43 | M&L for 75mm thick plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregates) as in floors, plinth protection, pavings, etc. surface finished even and fair, laid in alternate bays/panels and joints filled with bituminous mix of 1 part bitumen and 3 part of sand complete all as specified and as directed |
| 44 | M&L for plain cement concrete 1:4:8 (type D-2) using 40mm graded stone aggregate as foundation filling, mass concrete, etc. complete all as specified and as directed |
| 45 | M&L for plain cement concrete 1:3:6 (type C-1) using 20mm graded stone aggregate as in beds of drains, surface channels, foundations of manholes, etc. complete all as specified and as directed |
| 46 | M&L for extra in forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc. complete all as specified and as directedNote: Inner girth shall only be measured |
| 47 | Add or deduct for each 25mm girth or part thereof over or under 30cm (for adjustment in girth in item No. 46 hereinabove) |
| 48 | M&L rendering 10mm thick, in cement mortar (1:3) mixed with integral water proofing compound @3% by weight of cement, finished even and fair without using extra cement on roof slabs complete all as specified and as directed |
| 49 | M&L rendering 10mm thick, in cement mortar (1:6) on walls / concretesurfaces, etc. finished even and fair without using extra cement complete all as specified and as directed |
| 50 | M&L rendering 15mm thick, in cement mortar (1:4) on walls / concretesurfaces, etc. in two layers (10+5mm) finishing layer mixed with integral water proofing compound @3% by weight of cement, finished even and smooth without using extra cement complete all as specified and as directedNote: WPC will be measured and paid separately under respective item herein |
| 51 | M&L rendering 15mm thick, in cement mortar (1:4) on walls / concretesurfaces, etc. finished even and smooth without using extra cement complete all as specified and as directed |
| 52 | Supply only integral water proofing compound all as specified |
| 53 | M&L for cleaning the dust,dirty and any other foreign material from roof surfaces and applying a coat of bituminous primer @ 0.40 ltr/sqm uniformly and primer shall be allowed to dry over night as conforming to IS 3384-1986, complete all as specified and as directed. |
| 54 | Supply and laying APP based polymeric membrane 3mm thick (minimum), weighting not less than 3.5 kg/sqm reinforced with polyester non woven fabric (weighting not less than 160gms/sqm) applied over primed surfaces by torching application as per manufacturer\"s instructions with overlaps minium 100mm on the transverse directions and 75mm in longitudinal directions, including one coat of bituminous primer over the APP modified membrane @0.11 Kg/Sqm complete all as specified and as directed |
| 55 | M&L for preparation of masonry / concrete wall surfaces and applying1mm thick wall care putty rubbed with sand paper for making surface smooth and even including all necessary staging, scaffolding, etc. as required to work at heights, etc. complete all as specified and as directed |
| 56 | M&L preparation of newly plastered / unplastered surfaces and applying three coats of white wash on walls, etc. complete all as specified and as directed |
| 57 | M&L preparation of newly plastered / unplastered surfaces and applying three coats of white wash on ceilings, etc. complete all as specified and as directed |
| 58 | M&L for preparation of new masonry / concrete wall surfaces and applying two coats of oil emulsion distemper over a coat of wall primer including all necessary staging, scaffolding, etc. as required to work at heights, etc. complete all as specified and as directed |
| 59 | M&L for complete removal and preparation of old decorated surfaces of walls by brooming down or steel wire brushing, scrapping down smoke shoots, moulds, moss and efforescent salts, trading oil, greasy spots, etc.and applying two coats of white wash including all necessary staging, etc. as required complete all as specified and as directed |
| 60 | M&L for preparing of old steel / metal surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) complete all as specified and as directed |
| 61 | M&L for preparing of new wood / wood based surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, tint as approved complete all as specified and as directed |
| 62 | M&L for preparing of new steel / metal surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer complete all as specified and as directed |
| 63 | M&L for preparing of new steel / metal surfaces of any description not exc 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer complete all as specified and as directed |
| 64 | M&L for preparation of new plastered surfaces and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, alkali & fungus resistant, dirt resistant, exterior paint (of approved tint, company depot tinted) with silicon additives @1.43litre/10sqm over a priming coat of exterior primer applied @0.90litre/10sqm complete all as specified and as directed |
| 65 | M&L for complete removal and preparation of old decorated surfaces of walls by brooming down or steel wire brushing, scrapping down smoke shoots, moulds, moss and efforescent salts, trading oil, greasy spots, etc. and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistant, dirt resistant, exterior paint of approved shade (company depot tinted) with silicon additives @1.43litre/10sqm over and including a priming coat of exterior primer applied @0.90 litre/10sqm including all necessary staging, scaffolding, etc.required complete all as specified as as directed |
| 66 | S&F pre-painted galvalume aluminum zinc coating GI based semi corrugated steel sheet 0.50mm thick of any colour (as approved) having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed |
| 67 | S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour (as approved) having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed |
| 68 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provisioning of binding wire complete all as specified and as directed |
| 69 | Supply only chain link MS galvanised fencing, any size or type complete all as specified and as directedNote: Weight of chain link shall be ascertained by a BOO ordered by the GE |
| 70 | Supply only mild steel conforming to Fe-410W grade E-250 quality-A, round bars 10mm dia, cut to length, bent to shape required and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in tie rods to chain link fencing complete all as specified and as directed |
| 71 | S&F in repairs galvanised 2 strand, steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossings with and including provision of galvanised mild steel wire, staples or steel pins, etc. including all necessary T&P, safety measures, staging, scaffolding, etc. to work at heights over security walls, etc. complete all as specified and as directed |
| 72 | M&L for suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system) of grid size 600x600mm with main runner 38x24mm and wall angle 24x24mm using 4mm thick high pressure non-asbestos fiber cement decorative board (E-Board Classic) in grid of GI system duly suspended from 4mm dia GI bar hanger fixed with steel dash fasteners or iron purlin from roof with adjustment clips, providing positions for light fixtures, air conditioning, diffuser and ducts, sprinkler, smoke detectors, etc., cnforming to IS 14862, the main runners duly secured to structural soffits by hanger @1220mm c/c (maximum) with the last hanger at the end of each main runner not interlocked between main runners @610mm c/c so as to form 600x600mm grid complete all as specified and as directed |
| 73 | M&L for non-skid ceramic tiles, coloured, area of tile exceeding 0.18sqm but not exceeding 0.38sqm each, 7 to 8mm thick of superior quality as in floors, etc. laid over 15mm thick screed bed in CM (1:6) (rate shall be included) set and jointed in neat cement slurry @3.00kg of cement per sqm and pointed in white cement mixed with colouring pigment to match shade of tiles complete all as specified and as directed |
| 74 | M&L for non-skid ceramic tiles, coloured, area of tile exceeding 0.18sqm but not exceeding 0.38sqm each, 7 to 8mm thick of superior quality as in vertical surfaces, dado, etc. jointed in neat cement slurry @3.00kg of cement per sqm and pointed in white cement mixed with colouring pigment to match shade of tiles, fixed over and including 10mm thick backing coat in CM (1:4) (rate shall be included) complete all as specified and as directed |
| 75 | M&L for non-skid ceramic tiles, coloured, area of tile exceeding 0.06sqm but not exceeding 0.11sqm each, 7 to 8mm thick of superior quality as in floors, etc. laid over 15mm thick screed bed in CM (1:6) (rate shall be included) set and jointed in neat cement slurry @3.00kg of cement per sqm and pointed in white cement mixed with colouring pigment to match shade of tiles complete all as specified and as directed |
| 76 | M&L for glazed ceramic tiles, coloured of size 350x250mm or 450x300x7 to 8mm thick, of superior quality B-III grade, on vertical faces, dados, skirting, risers, etc. laid over 10mm thick backing coat in CM (1:4) (rate shall be included) set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the colour of tiles complete all as specified and as directed |
| 77 | S&F factory made uPVC white colour sliding window three track area not exceeding 2.00sqmm each made of extruded profiles with wall thickness of 2.3mm(±0.2mm) window profile with hollow section with multi chamber frame (88mmx52mm), sliding sash (42mmx67mm), sliding mesh sash (42mmx57mm), sliding interlock(one vertical lenght in each shutter)(45mmx28mm), glazing bead (24.5mmx16mm) will be mitred cut and fusion welded all corners including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing hardware EPDM gasket1.2±0.2mm thick galvanised steel frame(30mmx18mm) 2 Nos, sliding sash (30mmx18mm), sliding mesh sash(26mmx10mm) profile to be inserted in required profile frame will be fixed to the wall with 8mmx100mm long fastener, hardware Touch lock of zinc alloyed (white powder coated), steel roller system,SS wire cloth 0.36mm nominal dia of wire and average width aperture 1.40mm and required accessories, complete all as specified and as directed.(Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessoires . Net opening will be measured for payment purpose) |
| 78 | S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed |
| 79 | S&F 3mm thick tinted glass ordinary quality and glazing with oil putting square not exceeding 0.5sqm in each pane complete all as specified and as directed |
| 80 | S&F pressed steel frames of size 105x60mm, fabricated out of 1.25mm thick MS sheet of profile 125x60mm, for doors / windows, with one or more rebates including necessary fixing lugs, stainless steel hinges (100/50mm), lock strike plate, shock absorber, 20mm dia 60mm long MS conduit for housing of aldrop bolt, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs, etc. complete all as specified and as directed |
| 81 | S&F pressed steel frames of size 125x60mm, fabricated out of 1.25mm thick MS sheet of profile 125x60mm, for doors / windows, with one or more rebates including necessary fixing lugs, stainless steel hinges (100/50mm), lock strike plate, shock absorber, 20mm dia 60mm long MS conduit for housing of aldrop bolt, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs, etc. complete all as specified and as directed |
| 82 | S&F factory fabricated solid PVC moulded door shutter with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with but 2mm thick moulded prelam PVC sheet on the front face & 2mm prelam PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and as directed |
| 83 | S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, smooth finish with lipping of teak wood on edges complete all as specified and as directed |
| 84 | S&F 100mm long stainless steel butt hinges of selected quality, with stainless steel hinge pin fixed with stainless steel screws complete all as specified and as directed |
| 85 | S&F in repair for rubber door seal 32mm wide and 5mm thick with aluminium strip of size 19mm wide fixed with machine steel screw with washer, complete all as specified and as directed |
| 86 | S&F 150mm floor door stopper aluminium alloy body and tongue, anodized with hard drawn steel spring fixed on floor complete all as specified and as directed |
| 87 | S&F factory made single extruded WPC (wood polymer composite) solid door / window / ceosetory windows and the like, frames / chowkhats of size 45x70mm comprising of virgin PVC polymer, flame retardant of class A category, termite/borer proof, weather proff, of K value 58-60 (suspension grade), calcium carbonate and natural fibres (wood powder/rice / wheat hsuk) built with non-toxic additives, fabricated with mitred joints with PVC solvent cement and screwed with full body threaded star headed stainless screws, fixed in position with MS hold fasts/SS dash fastners complete all as specified and as directedNotes: (i) MS hold fasts/SS dash fastners will be measured and paid separately under respective items herein (ii) Profile dimensions nof frame mentioned is minimum. However, in case of non-availability next higher section shall be used without any extra cost to the Govt. |
| 88 | S&F factory made single extruded WPC (wood polymer composite) soliddecorative type flush door shutters of size 24mm thick comprising of virgin PVC polymer, flame retardant of class A category, termite/borer proof, weather proff, of K value 58-60 (suspension grade), calcium carbonate and natural fibres (wood powder/rice / wheat hsuk) built with non-toxic additives, fabricated with mitred joints with PVC solvent cement and screwed with full body threaded star headed stainless screws, fixed in position with MS hold fasts/SS dash fastners complete all as specified and as directedNotes: (i) MS hold fasts/SS dash fastners will be measured and paid separately under respective items herein (ii) Profile dimensions nof frame mentioned is minimum. However, in case of non-availability next higher section shall be used without any extra cost to the Govt. |
| 89 | M&L for 17/18mm thick pre-laminated particle MDF type board, exterior grade, prelaminated on one side with decorative choice lamination and on other side balancing white lamination, fixed with screws to timber frame work and lipping of teak wood on outer frame allround complete all as specified and as directed |
| 90 | S&F hasp and staple of aluminium anodised, including bolt to hinge plate and fixed with screws150mm long, complete all as specified and as directed. |
| 91 | S&F fancy type extruded SS handle 150mm size , complete all as specified and as directed. |
| 92 | S&F in continous (piano) SS hinges 30mm widht of flaps(when open) fixed with screws, complete all as specified and as directed. |
| 93 | S&F magnetic catches with steel body \"H\" type fixed to shutter , complete all as specified and as directed. |
| 94 | S&F 250mm aluminium alloy, anodised sliding door bolt with hasp and staple, bolt type, with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed |
| 95 | S&F200mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and as directed |
| 96 | S&F 125mm extruded aluminum alloy handles, cast type, anodized complete all as specified and as directed |
| 97 | S&F anodized aluminium sections, powder coated (minimum 50micron) for door shutters with frame, three track sliding windows (2xglazed & 1xgauzed shutter), ventilator, partitions, etc including necessary jointing cleats, screws, etc. and fixed complete all as specified and as directed |
| 98 | S&F in repairs 25mm dia fancy type MS chromium plated (tint as approved) MS curtain / drapery rods, etc. of rod wall thickness 1mm (min), including pair of brackets, holders with funnel at ends complete all as specified and as directed |
| 99 | S&F steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed of the following bores: |
| 100 | 15mm |
| 101 | 20mm |
| 102 | Fixing only steel water tubing, medium grade, galvanised with screwed and socketed joints, including supply and fixing all fittings, ISI marked conforming to IS-1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed for the following bores:Note: Serviceable tubings obtained from dismantling herein before will be reused under this item |
| 103 | 15mm |
| 104 | 20mm |
| 105 | S&F in repairs vitreous China wash down water closet pan (Pedestal pattern), coloured (as approved), with \"P\" or \"S\" trap, including flush pipe, trap, connection to drain or outgoing pipe, anti-syphonic pipe, seat cover to match with colour of WC, closed pattern with flat bottom & cover and chromium plated mild steel or aluminum anodized hinge device and jointing and connecting up complete all as specified and as directed |
| 106 | S&F in repairs vitreous China wash hand basin, flat back of size 550x400mm, white excluding taps, waste chain, plug and porcelain stopperincluding CI brackets, cutting for and pinning in ends of brackets with coupling and including PVC connection 60cm key with brass union complete all as specified and as directed |
| 107 | S&F 10 litre capacity PVC valveless syphonic action type flushing cistern, low level white with inlet ball valve float and handle including brackets complete all as specified and directed. |
| 108 | S&F in repairs 15mm bib taps, chromium plated, cast copper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed |
| 109 | S&F in repairs 15mm dia pillar taps, fancy type, cast copper alloy, with capstain heads, chromium plated, screwed down, high pressure, with or without lettered \"HOT\"/\"COLD\", with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed |
| 110 | S&F in repairs 15mm dia stop cocks / angle valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions or for brass ferrule complete all as specified and as directed |
| 111 | S&F in repairs 15mm diastop angle valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions or for brass ferrule complete all as specified and as directed |
| 112 | S&F in repair two angle valves/two way tap with flange 15mm bore fancy type,half turn, cast copper alloy chromium platedwith long shank and cup screwed both ends for iron pipe or for unions, complete all as specified and as directed. |
| 113 | S&F in repairs for 15mm bore brass CP wall mixer, 2 in 1, of approved design, for mixing hot & cold water screwed down for iron pipe for over head shower with 115mm long bed pipe on upper side connecting legs and wall flanges, brass CP, fancy type and fixed, complete all as specified and as directed |
| 114 | S&F 600x450mm full sized bevelled edge mirror of selected quality glass mounted on 6mm thick commercial plywood with PVC beading all round and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed |
| 115 | S&F 15mm PVC connections, 450mm long with brass couplings, PTMT nuts, etc. complete all as specified and as directed |
| 116 | S&F in repairs towel rail, 20mm dia, brass chromium plated, 600mm long with fancy type with brass chromium plated brackets on both sides and fixed with steel screws and wooden/rawl plugs complete all as specified and as directed |
| 117 | S&F125mm dia CP brass shower rose with swivel joints, any colour including shower arm 15mm dia, 195mm long with bend of 45o with flange of CP brass complete all as specified and as directed |
| 118 | S&F towel ring, chromium plated, 9\"\" dia (minimum weight 90gms) of approved design, fixed with chromium plated screws and wooden/PVC rawl plugs complete all as specified and as directed |
| 119 | S&F 12mm thick glass corner shelf, 250mm radius bewteen flanges fixed with brass chromium plated D clamps including brackets complete all as specified and as directed |
| 120 | S&F 75mm dia PVC (SWR) floor trap with chromium plated grating jointed with solvent cement complete all as specified and as directed |
| 121 | S&F in repairs PVC (SWR) pipes, 110mm bore, single socketed in any length with rubber ring joints fixed on walls or laid in trenches/floor with suitable clamps, etc. complete all as specified and as directed |
| 122 | S&F in repairs PVC (SWR) pipes, 75mm bore, single socketed in any length with rubber ring joints fixed on walls or laid in trenches/floor with suitable clamps, etc. complete all as specified and as directed |
| 123 | S&F in repair 110mm bore PVC (SWR) bend of any radius complete all as specified and as directed |
| 124 | S&F in repairs 75mm bore PVC (SWR) bend of any radius with oval access door complete all as specified and as directed |
| 125 | S&F SS peg set of 4 hook as per sample kept in GE office, complete all as specified and as directed. |
| 126 | S&F in repair toilet paper holder with flap recessed type stainless steel complete all as specified and as directed |
| 127 | Supply and fix in repair Grating round 100 mm size of CP (Minimum weight 100gms) including PVC waste pipe complete all as specified and directed. |
| 128 | Supplying, hoisting, fixing and connecting up rotational moulded polythylene water storage tanks of capacity 1000 litres (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I including connecting the overflow drain out, inlet and outlet pipes, tank nipple, elbow, bend, unions, sockets, etc. including taking down old damaged water tank and disposing off complete all as specified and as directed. |
| 129 | S&F in20mm dia ball / float PTMT valves, weighing minimum 210gm, high pressure, with high density plastic / polythene float / ball, epoxy coated aluminium rod and flynut, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed |
| 130 | S&F in repairs gun metal globe or gate valve, 20mm dia with iron wheel head, screwed both ends for iron pipe and fixed including necessary cutting into existing pipe, threading, inserting new piece of GI pipe of existing size, breaking/cutting into cement concrete, masonry, etc. and making good the disturbed surfaces complete all as specified and as directed |
| 131 | E/M WORKS |
| 132 | Taking down copper / aluminium point wiring (light, fan, socket or power) including fixture and fittings viz. switches, ceiling roses, light fittings, pendants, regulators, sockets, etc. and disposing off complete all as specified and as directed |
| 133 | M&L for point wiring with 1.5sqmm, two single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade, IS-694 marked, with multi-stranded copper conductor, drawn through and including non-metallic heavy duty PVC conduit not less than 20mm dia and accessories concealed in walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly complete all as specified and as directed for the following: |
| 134 | One light pointcontrolled by one 5A one way switch |
| 135 | One ceiling/exhaust fanpoint controlled by one 5A one way switch |
| 136 | One switch socket outlet 3 pin 5A controlled by one switch on same board |
| 137 | One switch socket outlet 3 pin 5A controlled by one switch on independent board |
| 138 | M&L for point wiring with 2.5sqmm, two single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade, IS-694 marked, with multi-stranded copper conductor, drawn through and including non-metallic heavy duty PVC casing caping not less than 20mm wide and accessories flush on walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly for 3 pin 15A switch socket independent outlet complete all as specified and as directed |
| 139 | M&L for point wiring with 4.0sqmm, two single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade, IS-694 marked, with multi-stranded copper conductor, drawn through and including non-metallic heavy duty PVC casing caping not less than 20mm wide and accessories flush on walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly for 3 pin 15A switch socket independent outlet complete all as specified and as directed |
| 140 | S&F ceiling rose surface bakelite 65x50mm, ISI marked, with three terminals complete all as specified and as directed |
| 141 | S&F switch piano flush , single pole, ISI marked, one way 6A,230V complete all as specified and as directed |
| 142 | S&F switch piano flush , single pole, ISI marked, one way 15A,230V complete all as specified and as directed |
| 143 | S&F switch socketoutlet, 2 in 1, 3 pin, 5 A flush type, ISI marked, 230V complete all as specified and as directed |
| 144 | S&F switch socketoutlet, 2 in 1, 3 pin, 15 A flush type, ISI marked, 230V complete all as specified and as directed |
| 145 | S&F electronic fan regulator, stepped socket type (5 steps), 100W, 50Hz, 230V, ISI marked duly connected up complete all as specified and as directed |
| 146 | Taking down old unserviceable submain wiring of any type, any size, from any location or position and disposing off including making good the disturbed surfaces, etc. complete all as specified and as directed |
| 147 | M&L for submain wring using proper colour codingwith 2 runs of single core, PVC insulated,FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 1.5sqmm and 1 run of 1.5sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC casing capping 32mm wide, heavy duty, ISI marked concealed in wall/ceiling/roof, etc. with all required accessories complete all as specified and as directedNotes:(i) 2runs of 1.5sqmm main cable, 1 run of earth conductors and 1 run of PVC casing/capping shall be measured as one length(ii) Separate casing shall be used for each sub-main wiring circuit irrespective of numbers of wire(iii) The minimum size of casing shall be as stipulated, however higher sizes shall be used as per number of cables passing through. The Engineer-in-charge shall ensure for proper size of casing as per requirement at site |
| 148 | M&L for submain wring using proper colour codingwith 2 runs of single core, PVC insulated,FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 4sqmm and 1 run of 2.5sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC casing capping 32mm wide, heavy duty, ISI marked concealed in wall/ceiling/roof, etc. with all required accessories complete all as specified and as directedNotes:(i) 2runs of 4sqmm main cable, 1 run of earth conductors and 1 run of PVC casing/capping shall be measured as one length(ii) Separate casing shall be used for each sub-main wiring circuit irrespective of numbers of wire(iii) The minimum size of casing shall be as stipulated, however higher sizes shall be used as per number of cables passing through. The Engineer-in-charge shall ensure for proper size of casing as per requirement at site |
| 149 | M&L for submain wring using proper colour codingwith 2 runs of single core, PVC insulated,FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 6sqmm and 1 run of 4sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC casing capping 32mm wide, heavy duty, ISI marked concealed in wall/ceiling/roof, etc. with all required accessories complete all as specified and as directedNotes:(i) 2runs of 6sqmm main cable, 1 run of earth conductors and 1 run of PVC casing/capping shall be measured as one length(ii) Separate casing shall be used for each sub-main wiring circuit irrespective of numbers of wire(iii) The minimum size of casing shall be as stipulated, however higher sizes shall be used as per number of cables passing through. The Engineer-in-charge shall ensure for proper size of casing as per requirement at site |
| 150 | S&F LED batten with inbuilt driver made out of high qulaity aluminiu8m extruded housing and aluminium heat shrink for mounting LEDs, mercury free and decirativeend caps with maximum power consumption 9-20watt with min system lumious efficiency lumen/watt> 100 CT not less than 5700k and CRI>80, operating voltage of 140-270Volt AC, P.F > 0.90, 2.5KV surge protection and current THD <15% complete and including all other accessories as per manufacturer instruction, internally prewired including connecting up with twin core 0.75sqmm copper conductor flexible wire / cable , complete all as specified and as directed . |
| 151 | S&F LED light fitting mirror type with high output diffuser 10Watt , 2feet230Volt AC, decorative type with driver holder and LED lamp of suitable size, complete all as specified and as directed. |
| 152 | S&F BLDC ceiling fan 1200mm sweep, 230V, minimum air delivery 210CFM with service value 6.00 BEE 5 star rated, with blades, down rods and accessories and connecting up including disconnecting, taking down of old unserviceable fan and depositing to MES storeyard including all loading, unloading, carting, etc. complete all as specified and as directed |
| 153 | S&F heavy duty, PVC body with PVC blades, legs, ISI marked energy efficient exhaust fan,300mm sweep, 230V, 50Hz, 1200RPM, copper wound, with louvers and connecting up including provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to exhaust fan including grouting the nuts and bolts complete all as specified and as directed |
| 154 | S&F building security light, LED luminaire 30W IP-66 protection class, with 25W LED lamp, driver, etc. with all accessories complete all as specified and as directed |
| 155 | S&F angle bracket of 40mm dia GI tube light grade for fixing building security lightof 1m long, complete all as specified and as directed. |
| 156 | S&F electric water heaters (geysers), stainless steel body, 25litres capacity, storage type, vertical mounting, with glass lined inner tank, energy efficient 5 star rated of approved design and colour, including 2kW heating element, all necessary clamps, grouting duly with holding bolts & nuts and all necessary connections at locations, complete all as specified and as directed |
| 157 | Taking down main switches, sheet metal enclosures, DBs by disconnecting and blanking supply mains from any location/position and disposing off complete all as specified and as directed |
| 158 | S&F sheet metal enclosures for 8 way MCB DB, 240V, SPN, double door, IP 43 protection class conforming to relevant IS, with 200A rated insulated aluminium bus bar, neutral link, DIN rail, blanking plates, etc. duly flushed in wall and making good the disturbed surfaces complete all as specified and as directed |
| 159 | S&F metal clad socket outlet with single pole enclosure with 5 pin and earth plug socket including 1No. MCB SPN 20A 10kA 240V,complete all as specified and as directed |
| 160 | S&F MCB SPN, 240V, 40 to 63A, 10kA, 50Hz, C curve complete all as specified and as directed |
| 161 | S&F MCB SP, 240V, 5 to 32A, 10kA, 50Hz, C curve complete all as specified and as directed |
| 162 | Excavation in trenchesnot exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc. not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed |
| 163 | Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed |
| 164 | Removing excavated materialsto a distanceexceeding 1.5Km but not exceeding 5.00km and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed |
| 165 | M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directedNote: Only punned thickness of sand shall be considered for measurement purposes |
| 166 | Supply and laying burnt bricks of sub-class \"B\" designation 75 of size 230x115x75mm laid in trenches for cable protection complete all as specified and as directed |
| 167 | Supply, fixing, commissioning and testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductors, 1100V grade 3.5 core 25sqmm laid in trenches/fixed to wall/under road/drawn through pipes etc. with copper cable glands and copper thimbles including taking down old unsv cables, complete all as specified and as directedNote: Excavation and earthwork will be measured and paid under respective items herein |
| 168 | S&F steel water tubing, light grade, 40mm bore, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for cable protection, etc.including taking down old usv GI pipe, complete all as specified and as directed |
| 169 | M&L for 100mm thick plain cement concrete 1:3:6 (type C-2) using 40mm graded stone aggregate asflooring, etc.complete all as specified and as directed |
| 170 | S&F gun metal globe or gate valve, 25mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed |
| 171 | S&F steel water tubing, medium grade, 25mm bore, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for cable protection, etc.including taking down old usv GI pipe, complete all as specified and as directed |
| 172 | M&L for cutting into existing 25mm bore GI pipes in position and any location for insertion of tees, tail piece, collars, branch pipes, reducers, etc. at any required length for branch connection, etc. complete all as specified and as directedNotes: (a) Excavation and earthwork will be measured and paid separately under respective items herein(b) Both sides cut shall be measured as one unit |
| 173 | Supply & Erection of Galvanized steel high mast lighting system of 15 meter in two section, 3mm section thickness, top dia 150 mm bottom dia 340 mm, with 2/3 wire rope system and its accessories, 3 phase motor system for taking up/down the light fixing arrangement of the high mast controlled from the timer switch panel including suitable size of RCC foundation and anchoring with nuts and bolts and suitable for loading 06 Nos 120 watt LED lights symmetrically fitted along with their control gear and having two point suspension system with stainless steel wire rope of 6 mm dia 97/19 guage and double drum winch with luminare mountng arm, pully assembly, aviation obstruction light. Lightning arrestor spike including RCC foundation as per height compelete all as per manufacturers instructions,specified and as directed with the following details :- |
| 174 | (A) Details of High Mast System :(i) Height of Mast:15 Mtr.(ii) No. of Sections :Two Sections(iii) Material construction: S355 grade as per BS:EN10 025 or equivalent(iv) Base dia, and top diameter (A/F): Top dia 150 mm (minimum) & Bottom dia 610 mm (minimum)(v) Plate Thickness : Top 4 mmMiddle : 4mm Bottom : 6mm or higher thickness(vi) Type of Joints : Stress fit at site(vii) Length of overlap: Top: 600 mm, Bottom: 800mm (minimum)(viii) Provision for cable termination : MCB Isolator(ix) Diameter of base plate: 840 mm (minimum)(x) Thickness of base plate :30 mm (minimum)(xi) Lightning protection finial: G.I single spike of length 1200 mm (minimum)(xii) Size of opening & door at base : 1200 mm x 250 mm (minimum)(xiii) Lightning protection finial: G.I single spike of length 1200 mm (minimum)(xiv) PCD of foundation bolts: 700 mm (minimum). |
| 175 | TheHigh mast shall be of continuously tapered, polygonal cross section, at least 20 sided, presenting a good and pleasing appearance.The mast shall be manufactured using special steel plates, conforming to BS-EN10-025.Each section shall be fabricated out of single plate duly folded and welded.There shall be only one longitudinal seam weld per section.The mast structure shall be suitable to sustain an assumed maximum reaction arising from a wind speed as per IS 875 (three second gust), and shall be measured at a height of 10 meters above ground level.The design life of the Mast shall be atleast 25 years.(B) Lantern Carriage : The Lantern Carriage shall be of special design and shall be of steel tube construction, the tubes acting as conduits for wires, with holes fully protected by grommets.The Lantern Carriage shall be so designed and fabricated to hold the required number of flood light fittings and the control gearboxes, and also have a perfect self balance.(C) WINCH:For Raising and lowering the lantern carriage for the installation and maintenance of the luminaries and lamps, a suitabe Winch arrangement shall be provided with the winch fixed at the base of the Mast and the specially designed hard frame assembly at the top.The winch shall be of completely self sustaining type, without the need for brake shoe, springs or clutches.Each driving spindle of the winch shall be positively locked when not in use, gravity activated PAWLS.Individual drum also should be operated for fine adjustment of lantern carriage. |
| 176 | Details of Winch/Power tool(i) Type/SWL of winch:Double drum, SWL 750 Kg(ii) Method of opertion : Motorized(iii) Motor capacity: 1.5 HP (minium)(iv) Torque limitor: With mechnical tripping facility(D) Head Frame : The head frame, which is to be designed, as a capping unit of the mast, shall be of welded steel construction, galvanized both internally and externally after assembly.The top pully shall be appropriate diameter, large enough to accommodate the stainless steel wire ropes and the multi-core electric cable.The pulley block shall be made of non-corrodable material, and shall be of die cast Aluminium Alloy (LM-6).(E) Stainless Steel Wire Ropes:The suspension system shall essentially be without any intermediate joint and shall consist of only non-corrodable stainless steel of AISI-316 grade.The stainless steel wire ropes shall be of 7/19 construction, the central core being of the same material.The overall diameter of the rope shall not be less than 6mm, safety of over 5 for the system at full load as per the TR-7 referred to in the beginning of this specification.The end constructions of ropes to the winch compression splices.Two continuous lengths of stainless steel wire ropes shall be used in the system and no intermediate joints are acceptable in view o the required safety.No intermediate joints/ terminations. Either bolted or else, shall be provided on the wire ropes between winch and lantern carriage. |
| 177 | Details of Stainless Steel Wire Rope:(i) Grade/construction : AISI 316,7/19 construction(ii) Number of roples:Two continuous(iii) Diameter: 6 mm (minimum)(iv) Braking load capacity : 2250 kg x 2 (minimum)(F) Power Tool for the Winch: A suitable, high-powered, electrically driven, internally mounted power tool, with manual over ride shall be supplied for the raising and lowering of the lantern carriage for maintenance purposes.The speed of the power tool shall be to suit the system.The power toolshall be single speed, provided with a motor of the required rating.The power tool shall be supplied complete with suitable control.The capacity and speed of the electric motor used in the power tool shall be suitable for the lifting of the design load installed on the lantern carriage.The power tool mounting shall be so designed that it will be not only self-supporting but also aligns the power tool perfectly with respect of the winch spindle during the operations.Also a handle for the manual operation of the winches in case of problems with the electrically operated tool shall be provided and shall incorporate a torque limiting device.The power tool operation shall always be through a separate torque-limiting device to protect the wire ropes from over stretching.It shall be mechancial with suitable load adjusting device.The torque limitor shall trip the load when it exceeds the adjusted limits.There shall be suitable provision for warning the operator once the load s tripped off.The torque limitor is a requirement as per the relevant standards in view of the overall safety of the system.Each mast shall have its own power tool motor. |
| 178 | (G) Aviation Obstruction Lights :Suitable Aviation Obstruction Lights of reliable design and reputed manufcturer shall be provided on top of each mast.(H) Earthing Terminals:2Nos, earth terminal using 12mm diameter stainless steel bolts shall be provided at a convenient location on the base of the Mast, for lightening and electrical earthing of the mast.Each mast shall be earthed at two points using minimum 25x6 mmGI strip.Note : The quoted rate is deemed to include the cost of aviation obstruction light, Lightening arrestor spike, required suitable size of RCC foundation for the high mast pole and 4mm GI wire for earthing connection from LA spikes at top of the pole to the earthing point. |
| 179 | Supply,install,testing and commissioning of Servo Controlled volatge stabilizer 250KVA (confirming to BIS:9815:Part-I:1994 reaffirmed 20229), operating of 3 Phase,50Hz AC supply , naturally cooled, indoor type,unbalance type,copper wound, having digital display, suitable for relay free & silent operation including first filling of oil of suitable grade recommended by OEMas per IS:335:1993 reaffirmed 2005 having following generic specification complete all as specified and as directed.(a) Input voltage 300V-480V or as per requirement(b) Output violtage stabilized at any designed/desired volatge 415V+-1% (adjustable)(c) Rated frequency 50Hz(d) No distortion in wave(e) response time not to exceed 10 mili seconds(f) Sensitivity (±)1%(g) Rate of correction 8V/seconf for single phase and 20V/second for phase to phase(h) No load losses less than 0.5%(j) Full load losses less than 2.5%(k) Duty cycle- continous 24x7(l) Efficiency more than 95%(m) Type of load: 3 phase, unbalance type(n) Digital display Voltmeter/Ammeter(o) Capacity :250KVA(p) Make: Vinitech/krykard/Servomax/APLAB |
| 180 | Protection:(a) Overload/short circuit protections(b) High/low voltage cut off(C ) By pass arrangement in case of emergency(d) Single phase sequence change protection(e ) Ingress protection (IP) upto IP42/IP45 |
| 181 | M&L for cable jointing kit for 1100V grade cable for indoor/putdoor end termination/straight throughend jointing heat shrinkable type joint with jointing material and accessories suitable for 3.5 core 120mm², XLPE insulated armoured aluminium conductor cable , complete all as specified and as directed |
| 182 | Supply, fixing, commissioning and testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductors, 1100V grade 3.5 core 120sqmm laid in trenches/fixed to wall/under road/drawn through pipes etc. with copper cable glands and copper thimbles, complete all as specified and as directedNote: Excavation and earthwork will be measured and paid under respective items herein |
| 183 | Supply, fixing, commissioning and testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductors, 1100V grade 4 core 16sqmm laid in trenches/fixed to wall/under road/drawn through pipes etc. with copper cable glands and copper thimbles, complete all as specified and as directedNote: Excavation and earthwork will be measured and paid under respective items herein |
| 184 | M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directedNote: Only punned thickness of sand shall be considered for measurement purposes |
| 185 | Supply and laying burnt bricks of sub-class \"B\" designation 75 of size 230x115x75mm laid in trenches for cable protection complete all as specified and as directed |
| 186 | M&L for cutting existing roads/PCC drain for taking out UG cable and including necessary earthwork and making good to match with existing surface with PCC 1:3:6 type C1 using 20mm graded aggregates, complete all as specified and as directed. |
| 187 | S&F steel water tubing, light grade, 40mm bore, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for cable protection, etc., complete all as specified and as directed |
| 188 | Supply,install,testing and commissioning of digital 24 hr, 3 phase, street light panel having max load 6KW, Contactot rating 32A three phase,MCB rating 40Amp TPN,IP 54 protection, complete all as specified and as directed. |
| 189 | S&F 120W LED floodlight fitting, pressure die cast aluminium housing with heat resistant toughened glass, IP-66 protection having efficiency >110LPWluminaries with impact and corrosion , complete all as specified and as directed |
| 190 | M&L for earthing using copper earthing strip with copper steel earth plate electrode 600x600x3.15mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including copper strip of size 20x3mm extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm medium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications complete all as specified and as directed |
| 191 | M&L for earthing using GI earthing wire with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI earth lead wire 4mm dia extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 15mm light grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications complete all as specified and as directed |
| 192 | Notes for serial item No. 190 to 191: (i) The cost of GI earth continuity wire / strip with GI pipe 20mm medium grade upto 7.5m is deemed to be included(ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item(iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail