Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 24-11-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 29-11-2025 |
| 2 | 17-11-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 24-11-2025 |
| Sl. No. | Item Description |
| 1 | Dismantling of overhead ACSR (Aluminium conductor steel reinforced)from existing electric pole andremoving unserviceable ACSR from site and store carefully the serviceable ACSR after cleaning and complete all as specified anddirected. |
| 2 | Labour only for Re-fixing the serviceable Aluminum conductor steel reinforced (ACSR) conductoras in LT/HT overhead electric line and stretching the same with required span, standard sag and binding the conductor with pin/shackle insulator and jumpers with aluminum binding wire not less than 2.00mm dia, PG clamp etc complete all as specified and directed.Note: Serviceable ACSR will be received from Item No. 1 above of this Schedule.T&P required will be provodided by the contractor. |
| 3 | Materials and labour forAluminum conductor steel reinforced (ACSR) conductor ,Wiesel type as in HT/LT overhead electric line and stretching the same with required span, standard sag and binding the conductor with pin/shackle insulator and jumpers with aluminum binding wire not less than 2.00mm dia, PG clamp etc complete all as specified and directed. |
| 4 | Dismantling/taking down of insulators of any type/size from HT/LT poles/DOs/GODs complete all as specified and directed. |
| 5 | Dismantling of existing old cross arms etc made of mild steel channel, angle iron, flat iron, back plates, nuts, bolts, washers etc complete all as specified and directed. |
| 6 | S&F Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia. for 11000 volts grade complete all as specified. |
| 7 | S&F Disc type insulator, porcelain, vitreous, 145 mm high and 255 mm dia, ball & socket type, white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified and directed. |
| 8 | ~Ditto~ All as per item No 06 here in before but 100 mm height, 65 mm dia for 1100 Volts grade complete all as specified and directed. |
| 9 | S&F Shackletype, porcelain, vitreous, white, brown or green insulator includinggalvanised mild steel straps 31 x 3 mm, washers, insulator bolts and washers and nut of height 75 mm and90 mm dia for working pressure 1100 Volts complete all as specified and directed. |
| 10 | M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural mild steel sections conforming to Fe-410-0 grade including necessary nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape and size as directed and including applying two coats of aluminium paint (under & finishing coats) over a coat of red oxide zinc chromate primer on exposed steel surfaces complete all as specified and directed. |
| 11 | Supply and fixing triple pole mechanically operated air break isolator (GOD), vertical mounting, rotating type, mounted on insulator and steel frame with operating mechanism worked from ground level complete in all respect such as gun metal moving contacts and spring loaded gun metal fixed jaws, knife copper jumper strip etc, suitable for 11000 Volts grade, with 9 insulator of rating upto 200 Amps includingtaking down old unseviceable complete all as specified and directed.Make: Pactil/BHEL/Jaypuria Brothers |
| 12 | Supply and fixing expulsion type drop out fuse unit suitable for 11000 volt and current rating upto 200 Amps shall be mounted on and including MS channel complete with two post insulator for 11000 volts including necessary clamps, nuts, bolts , washers, the exposed steel surface shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. Make: Pactil/BHEL/Jaypuria Brothers |
| 13 | S&Fforlightning arrestor Expulsion type complete with all fittings, transmision/ distribution class , current rating 65 kA suitable for 11 KV system, discharge capacity 65 kilo amps and mounting on poles including all necessary bolts, nuts and washers and making electric connection and testing on completion complete all as specified and directed.Make:- SCHNENIDER orBHEL or GE POWER or W/S INSULATORS or SOUTHERN INSULATORS or OBLUM as approved by GE. |
| 14 | Supply and filling in Transformers, Transformer oil of dielectric strength not less than 40 KV, conforming to IS-335complete all as specified and directed.Make: Transol,Power oil |
| 15 | M & L for replacement of gasket including arresting leakage oftransformer oil by after draining out of transformer oil and refilling after replacement including disconnecting power supply complete all as specified and as directed for distribution transformer outdoor type 11 kV /415 volts having capacity upto 630 kVA complete all as specified and directed. |
| 16 | Dehydration and filtration of existing transformer/Servo Stablizer oil of transformer at different location with filtration machine and heating system to get the minimum di-electric strength of oil 50 kV minimum without disturbing the power supply system and refilling/ topping up /replacement of unserviceable transformer oil conforming IS-335-1993 complete all as specified and directed.Note: (a)Transformer oil required extra for filling/topping up shall be measured and paid separately under the relevant items of this schedule(b) cost of oil testing shall be deemed to be included in the unit rate quoted for this item and T&p Shall be aranged by contractor. |
| 17 | S & F breather including silica gel, indicating type, 4 to 6 mm standard size of the particle, blue colour for transformer of capacity from 63 to 400 kVA, 500 gm incl removing of old breather complete all as specified and directed. |
| 18 | M&L for Repair to transformer after disconnecting in coming HT connection and out going LT cable connection, draining out the transformer oil and keep in safe custody for reuse, disconnecting the breather assembly, temperature gauge, taking out the top cover of transformer upto 630 KVA, indoor/outdoor type, 11KV/433 Volt, step down, disconnecting LT/HT winding connections from LT/HT Bushing and carefully taking out LT/HT Bushing insulator and HT/LT Brass spindle, taking out gaskets of LT/HT Bushings and transformer top cover. Refixing exisitng LT/HT Brass spindle with Bushing insulators after replacing Gaskets, View glass of conservator tank, refixingall cable connections, top cover with new gasket, breather/temp gauge, refilling transformer oil, complete all as specified and directed. Note: Transformer oil for topup, dehydration/filtration etc work will be measured and paid separately. |
| 19 | S & F in repair porcelain HT bushing vitreous, brown colour, 11 KV grade along with a set of oil seals & copper alloy stud, nuts, washers etc. including dismantling existing HT bushing with copper alloy rod and disconnection of electrical connection, of suitable size for primary side (HT side ) of outdoor type 11 KV for 200 kVAdistribution transformer of any make complete all as specified and directed. |
| 20 | S & F in repair porcelain LT bushing vitreous, brown colour, 440 V grade along with a set of oil seals & copper alloy stud, nuts, washers etc. including dismantling existing LT bushing with copper alloy rod and disconnection of electrical connection, of suitable size for Secondary side (LT side ) of outdoor type 440V for 200 kVAdistribution transformer of any make complete all as specified and directed. |
| 21 | M & L for spray painting of transformers (any type power or distribution)) of capacity upto and including 630 kVA ( in situ ) outdoor type, installed and located at different sites in scattered area under the AGE E/M (P) No-1 Jabalpur including the following: -(a) preparation of old surfaces by cleaning, scrapping, rubbing/ polishing etc. complete all as specified and directed.. (b) painting with two coats of synthetic enamel paint of approved make / quality all as directed at site. (c) Writing the SM MES No of transformer on MS body of transformer all as directed . |
| 22 | Supply only Bamboo Ladder of length 20 feet for maintenanceworks of pole light ,2/4 pole structure etc complete all as specified and directed. |
| 23 | Excavation in trenches in hard/dense soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth for laying of cable and not exceeding 10 Sqm on plan for poles, struts, stays etc. and not exceeding 1.5 m in depth and getting out complete all as specified and directed. |
| 24 | Returning, filling in, trenches including spreading leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 25 | Removing excavated material to a distance not exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed. |
| 26 | Supply and laying sand cushioning with dry sand over and under the under ground cable in trenches, ducts for cable protection 150 mm below & 80 mm above the cable as protection of cable complete as specified & directed. Note : Punned thickness of sand shall be measured & paid complete all as specified and directed. |
| 27 | Supply,laying & fixing double wall corrugated (DWC) pipes made of high density polythyline (HDPE) of size 50 mm outer dia and 38 mm inner dia of with all accessories i.e. all type of joints,Sockets,Elbows,bends and End caps etc. complete all as specified and directed.Make-Telerex/Tirupati or approved by GE |
| 28 | Cutting the existing hard standing/road and making good after laying of cable/pipe with 100mm thick PCC 1:2:4 mix, type B-I including finishing to match existing surfacescomplete all as specified and directed. |
| 29 | Taking out old unserviceable, burnt, punctured aluminium conductor cable of any grade and cross sectional area from the excavated trenches, ducts, laid in floors, along poles/ walls/ equipments etc., laid and passed through pipes or laid bare in road crossing/drains/ paths/along walls/poles/floors etc and in similar locationscomplete all as specified and directed. |
| 30 | Supply and laying or fixing or passing in trenches/ on pole/ through pipes,11000 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 120 sqmm, 3 core conforming to IS 7908 / (PART-I) 1988 with the latest amendments includingjointing materials such as cable glands & lugs etc and testing oncomplete all as specified and directed. |
| 31 | Supply and laying or fixing or passing in trenches/ on pole/ through pipes,11000 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 95 sqmm, 3 core conforming to IS 7908 / (PART-I) 1988 with the latest amendments includingjointing materials such as cable glands & lugs etc and testing oncomplete all as specified and directed. |
| 32 | Supply and laying or fixing or passing in trenches/ on pole/ through pipes,1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor conforming to IS 7908 / (PART-I) 1988 with the latest amendments includingjointing materials such as cable glands & lugs etc and testing on completioncomplete all as specified and directed. etc of the under mentioned type and sizes :- |
| 33 | (a) 185 Sqmm 3.5 core |
| 34 | (b)120 Sqmm 3.5 core |
| 35 | (c) 95 Sqmm 3.5 core |
| 36 | (d) 70 Sqmm 3.5 core |
| 37 | (e) 50 Sqmm 3.5 core |
| 38 | (f)25 Sqmm 3.5 core |
| 39 | (g) 16 Sqmm 4 core |
| 40 | (h)10 Sqmm 2 core |
| 41 | Supply and fixing in repair HT 11 KV (Earthed) grade heat shrinkable end termination jointing kit outdoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 -185 sqmm complete all as specified and as directed. |
| 42 | Supply and Fixing in repairEnd termination joints, indoor type, designed to withstand exposure to extreme climatic variations & surface contamination, UV rays from sunlight and electrical stress caused due to heavy pollution & dust in external conditions. 1100 Volt, XLPE ,Heat Shrinkable, suitable for cable 70-150sq mm, 3.5/4 Core and complete all as specified and directed.Note : (i) The accessories shall be supplied in kit form. Each component of the kit shall carry the manufacturer’s mark of origin. (ii) As per the IS 13573 (Part-I&II):2011 all kits shall be marked and labeled suitably for identification. (iii) Rate are inclusive of removing old U/S joints complete as required. |
| 43 | Supply and Fixing in repairEnd termination joints, indoor type, designed to withstand exposure to extreme climatic variations & surface contamination, UV rays from sunlight and electrical stress caused due to heavy pollution & dust in external conditions. 1100 Volt, XLPE ,Heat Shrinkable, suitable for cable 25-50sq mm, 3.5/4 Core and complete all as specified and directed.Note : (i) The accessories shall be supplied in kit form. Each component of the kit shall carry the manufacturer’s mark of origin. (ii) As per the IS 13573 (Part-I&II):2011 all kits shall be marked and labeled suitably for identification. (iii) Rate are inclusive of removing old U/S joints complete as required. |
| 44 | Supply & Fixing in repairs Danger notice plate for LT, 20 x 15cm x 1.60 mm thick, mild steel sheet, vitreous, enamelled white, with letters, figures and conventional skull & bones in single red colour and fixed on LT Panel using suitable nuts, bolts and washers of required size complete all as specified and directed. |
| 45 | M & L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25 x 20 cm size complete all as specified and directed. |
| 46 | Taking out old unserviceable, GI tubing of any size upto 80 mm bore from the excavated trenches, ducts, floors, along poles/ walls/ equipments, road crossing/drains/ paths etc complete all as specified and directed. |
| 47 | Supply and lay in trenches/under roads/crossings or fixed to wall/pole/roof, GI tubing light grade of following sizes for protection of UG cables :-complete all as specified and directed.Note : Payment for excavation, earth work, PCC shall be paid for separately under relevant items of Schedule. |
| 48 | (a) 80 mm dia |
| 49 | (b) 50 mm dia |
| 50 | (c) 40 mm dia |
| 51 | Labour only for prunning of tree branches touching to electric overhead lines with growth around LT/HT over head lines and around pole and stay complete to make clear span of 3 mtron either side all around the Over Head line with all tools, plants etc complete all as specifed and as directed.Note :- (i) Any breakdown of line occured during prunning shall be made good without any extra cost . |
| 52 | Disconnecting all cable connections and taking out u/s MCCB/MCBs any type/capacity upto 400 Amps, TP/FP/TPN, 415 Volt from Panel Boards/feeder boxes and remove from site complete all as specifed and as directed. |
| 53 | Supply & Fixing MCCB, 4 Pole, 350 Amps, with electronic release, 415 Volt, 36 KA, including connecting up using suitable size of lugs complete all as specifed and as directed. |
| 54 | Supply & Fixing MCCB, 4 Pole, 250 Amps, with electronic release, 415 Volt, 36 KA, including connecting up using suitable size of lugs complete all as specifed and as directed. |
| 55 | Supply & Fixing MCCB, 4 Pole, 200 Amps, with electronic release, 415 Volt, 36 KA, including connecting up using suitable size of lugs complete all as specifed and as directed. |
| 56 | Supply & Fixing MCCB, 4 Pole, 160 Amps, with electronic release, 415 Volt, 25 KA, including connecting up using suitable size of lugs complete all as specifed and as directed. |
| 57 | Supply & Fixing MCCB, 4 Pole, 100 Amps, 415 Volt, 16 KA including connecting up using suitable size of lugs complete all as specifed and as directed. |
| 58 | Supply & Fixing MCCB, 4 Pole, 63 Amps, 415 Volt, 16 KA including connecting up using suitable size of lugs complete all as specifed and as directed. |
| 59 | Supply and errect Steel tubular swaged poles type 410 SP-31 (9.0 metres long) complete with MS base plate, finial taper plug, bolts, nuts, screws and top cover, with single swan neck bracket all as specified, directed and including the following:- (a) Excavation in trenches not exceeding 1.5 mtr wide and 1.6 mtr deep for pole foundation and getting out in soft/loose soil, returning filling in the excavation of soil after fixing the pole in foundation ramming earth around in layer not exc 25cm thick and disposal of surplus soil to a distance not exc 50 mtrs. (b) Material and labour for providing PCC 1:4:8 type D-2, using 40mm graded stone aggregate as in foundation, 600 mm x 600 mm cross section for 150 mm and PCC 1:3:6 type C-2, using 40mm graded stone aggregate as in foundation, 600 mm x 600 mm cross section planting depth 1.5 mtr for concrete casing the pole upto GL complete all as directed. (c) Material and labour for providing PCC 1:2:4 type B-1, using 20mm graded stone aggregate for plinth block/collar above GL 300 mm high and 600 mm x 600 mm cross section all as directed. (d) Material and labour for painting of pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block/concrete collar with two coat of aluminium paint over a coat of red oxide steel primer for preparation of surface complete all as specifed and as directed. |
| 60 | Supply and errect Steel tubular swaged poles type 410 SP-55 (11.0 metres long) complete with MS base plate, finial taper plug, bolts, nuts, screws and top cover, with single swan neck bracket all as specified, directed and including the following:- (a) Excavation in trenches not exceeding 1.5 mtr wide and 1.6 mtr deep for pole foundation and getting out in soft/loose soil, returning filling in the excavation of soil after fixing the pole in foundation ramming earth around in layer not exc 25cm thick and disposal of surplus soil to a distance not exc 50 mtrs. (b) Material and labour for providing PCC 1:4:8 type D-2, using 40mm graded stone aggregate as in foundation, 600 mm x 600 mm cross section for 150 mm and PCC 1:3:6 type C-2, using 40mm graded stone aggregate as in foundation, 600 mm x 600 mm cross section planting depth 1.5 mtr for concrete casing the pole upto GL complete all as directed. (c) Material and labour for providing PCC 1:2:4 type B-1, using 20mm graded stone aggregate for plinth block/collar above GL 300 mm high and 600 mm x 600 mm cross section all as directed. (d) Material and labour for painting of pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block/concrete collar with two coat of aluminium paint over a coat of red oxide steel primer for preparation of surface complete all as specifed and as directed. |
| 61 | Supply and fix in repairs road lighting luminaires, 70 watts, 230 Volthigh power LED with unique peanut lens for uniform distribution,IP 65/66 rated SPD, potted type driver higher spacing between poles,fixing it in new bracket (paintimg the bracket with one coat of red oxide and one coat of aluminum paint)and connecting it with pole mounted junction box with 2.5sqmm 2 core copper conductor complete all as specifed and as directed. |
| 62 | Supply and fix in repairs road lighting luminaires, 90 watts, 230 Volthigh power IP 65/66 rated LED with unique peanut lens for uniform distribution, higher spacing between poles,fixing it in new bracket (painting the bracket with one coat of red oxide and one coat of aluminum paint)and connecting it with pole mounted junction box with 2.5sqmm 2 core copper conductor complete all as specifed and as directed. |
| 63 | Supply and fixing in repairs on Pole/Wall Flood light fittings for use with LED lamps, 120 watts, 230 Volt, with high quality lenses & reflector,with toughened glass cover, IP-65/66 rated class of protection, complete with control gear and complete all as specifed and as directed. |
| 64 | S & F Solar street light LED 36W/40W, all in one having PIR sensor, high power LED\"s, MPPT controller, mono crystlline solar panel 38 + 4 Watt battery (30Ah) Life P 04, etruded aluminium having including suitasle size of GI Pole, ISF marked mounting structure, all regd accesories etc complete all as specifed and as directed. |
| 65 | Supply and fixing in repairs of LED Street light by taking down the street light from the pole including cleaning, changing the clamps , nut bolts ,and replacing the electronic driver of specified LED Light fittings upto 200 watt make as per site requirement complete all as specifed and as directed. |
| 66 | Supply and Fixing in repairs, LED bollard light in cylindrical shape with opal acrylic diffuser and IP66 protection 9 watts LED, 3000K, 230 Volt, duly errected on ground, with Cable entries for through-wiring of mains supply cable,Protection class IP66, Suitable for operation on 240V, 50Hz single phase ac supply complete all as specifed and as directed. Bajajor equivalent. |
| 67 | Supply and Fixing in repairs, LED Post Top Lantern in conical shape polycarbonate opal and clear diffuser with IP65/66 protection 25 watts LED, 3000K, 230 Volt, duly errected on ground/wall in 40/50 mm GI pipe, with Cable entries for through-wiring of mains supply cable, suitable for operation on 240V, 50Hz single phase ac supply complete all as specifed and as directed. (Note : GI pipe if required will be measured and paid separately.) Bajaj or equivalent in Havells. |
| 68 | Supply and Fixing in repairs, LED Post Top Lantern in conical shape polycarbonate opal and clear diffuser with IP65/66 protection 45 watts LED, 3000K, 230 Volt, duly errected on ground/wall in 40/50 mm GI pipe, with Cable entries for through-wiring of mains supply cable, complete all as specifed and as directed.(Note : GI pipe if required will be measured and paid separately.) |
| 69 | Taking down u/s street light/flood light/garden lights/Post top lantern fittings for use with LED lamps of capacity upto 200 watts complete with all accessories and keep the serviceable fittings in safe custody for reuse and remove the unserviceable fiitings from site complete all as specifed and as directed. |
| 70 | Preparing old painted surfaces of HT/LT Steel tubular poles including cross arms, back plates, bracings, all exposed surfaces of steel items fixed with the pole, without dismantling and M&L for painting with two coats of aluminium paint complete all as specifed and as directed. |
| 71 | Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth strip 32x 6 mmby means ofnut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. |
| 72 | Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth strip 25 X 4 mmby means ofnut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. |
| 73 | S&F in repair earth continuity conductor or main earth lead of aluminium strip 25 x 3.15 mm with saddles and fixing screw etc for roof conductor and down conductor fixed to wall on batten or recess or ground for connecting earthing to various equipments as required complete all as specifed and as directed. |
| 74 | M&L for PCC (1:2:4) type B2 using 40 mm graded stone aggregate as in foundation, filling, mass concrete andpilasters, buttresses columns, postsetc complete all as specified & directed. |
| 75 | M&L for PrecastReinforced Cement Concrete(RCC)1:2:4 type B1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form workand minimum reinforcement as per relevant IS codeand set in CM 1:6 complete all as specified and directed. |
| 76 | M&L for 40 to 80mm graded broken stone aggregate for spreading/ loose filling in the substation or other places where directed including stacking materials in regular heap/ stack for measurement complete all as specified and directed. |
| 77 | Supply & fixing in replacement, Brackets for street light fittings made out of 40 mm bore Light grade GI pipe, 1.5 Mtr length, bend to shape,including necessary Clamps made out of MS flat iron, nuts and bolts suitable for fixing with steel tubular/PCC Poles complete all as specifed and as directed. |
| 78 | S& F in repairs three core PVC insulated cables 1.5 Sqmm size, 1100 Volt grade with copperconductor and drawing into street light brackets/PVC Conduits and connecting with Junction Box and Street light fittings including continuous PVC insulated copper conductor three core copper conductor of size 1.5 Sqmm complete all as specifed and as directed. |
| 79 | S & F in repairsInfrared sensor based NATURE SWITCH three phase 8 kw consisting of power contactor, ACconforming to IEC - 60947 - 4 - 1/ IS - 13947 - 4 - 1 for load switching and terminal blocks.The enclosure is made of UV stabilized, FR grade special moulding compound to provide a rust proof, electric shock proof, termite proof, outdoor mountable electrically insulating body capable of enduring solar radiation in the outdoor & suitable formounting. The enclosure is provided with mounting brackets, cable glands, openable door with lock and key. Selectable options for duration based switching OFF as well as override facility for maintenance should be available complete all as specifed and as directed. |
| 80 | Supply and fix junction box made out of polycarbonate with IP 55/IP 65 protection of minimum size 155 x 210 x 92 mm,having terminals for termination of cable with necessary nuts and bolts, including -02 Nos polycarbonate cable gland, 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps in and including fixing clamp of FI 50 x 6mm with necessary nuts and bolts complete all as specifed and as directed. |
| 81 | M&L for Maintenance, servicing andcleaning ofvacuum circuit breaker unit & Bus bar chamberof 11 KV incoming VCB panel with CT chamber of capacity 400 Amps , ALSTOM make by taking out from panel by disconnecting all electrical connections, cleaning of all parts with CTC(Carbon tetrachloride) and clean cloth, removal of carbon deposited inside the moving contacts, greasing of all moving parts of the VCB, checking of complete operating mechanism for proper functioning, reporting for any defective parts, and refixing the same in their original positions and connections all cale connections and testing / calibration of IDMT relay installed at 11 KV main incomer /outgoing panels so as to facilitate instant tripping/ settingof panels in case of over current or earth fault , dismantling and re-fixing of connectingbusbar from CT to Busbar, spout, support insulator, opening of covers,cleaning using CTC and clean cloth and hot air blower, checking for any loose contact, tigtening of all nuts & bolts, refixing all coversincluding testing of complete VCB unit for proper functioning complete all as specified and directed.Note :- (a) Spare parts will be measured and paid separately.(b) Sevicing shall becarried out by authouried rep of VCB manufacture /State electricity board or as directed by Engr-in-Charge. |
| 82 | Supply only closing coilassembly 110 V DC to Areva make 11KV VCB including necessary connection testing complete incl dismantling taking down unsv complete one all as specified and as directed. Make- Areva/ ABB/ Schneider |
| 83 | Supply only tripping coil 110 V DC to Schneider make 11KV VCB incl necessary connection testing complete incl dismantling taking down unsv one complete all as specified and as directed. Make- Schneider,/ABB/ AREVA |
| 84 | Supply & Fixing in repairs Change Over Switch, On load, with front handle operaion, 4 Pole, 200 Amps capacity, 415 Volt, in sheet steel enclosure,weather/vermin proof, outdoor type, with front side hinged double door with locking arrangement complete and fixing on wall or any indicated position using suitable fixing accessories,including dismantling and taking out old u/s Change over switch and remove from sitereconnecting existing LT Cables with new Change over switchcomplete all as specifed and as dricted.Havells or equivalent. |
| 85 | Supplying and laying reinforced precast concrete cable cover, class LV Type 2 flat, size 300mm x 180mm x 40mm complete all as specified and directed. |
| 86 | M& L for cable root indicator MS sheet embossed with LT 1100 Volts Volts UGmade with CI Plate6 mm thick fixed with MS angle Iron of size 30x30x4mm of length 400 mm longincluding PCC work 1:2:4 type B1 of size 150x150x150 mm complete all as specifed and as dricted. |
| 87 | Material and labour for anti-climbing device, spike type fabricated from structural steel comprising of MS flat 20mmx6mm, MS round bar pointed, 8mm dia, 20cm length welded on MS flat fixed with nuts, bolts, washers and weldingwith and including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 88 | S & F drop out fuse unit explusion type for out door air break gang oprated switch single pole mounted on and including two numbers insulators for 11 KV working pressure fixed to MS channel with nuts, bolts and washer etc and current carry capacity above 50 Amp upto and 100 Ampcomplete all as specified and directed. |
| 89 | Supply only chain link MS galvanised fencing, any size or type complete all as specified and directed. |
| 90 | Fixing only chain link fencing including line wire, any mesh, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wires complete all as specified and as directed. |
| 91 | Supply and fixing mild steel Fe 410-W (Gde-E- 250) quality-A, framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. |
| 92 | Supply and fixing mild steel Fe 410-W (Gde-E- 250) quality-A, plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment complete all as specified and directed . |
| 93 | Material and labour for preparation of new steel surfaces of any description over 10 cm width or girthand applying one coats of synthetic enamel paint complete all as specified anddirected. |
| 94 | M&L for fabrication, supply and installation ofthe Back lit Glow sign board having coloured printedwith electric shock and treatment detailsor machinary history sheet as per following Specifications:-:(a) Box:1 The box size is approx2 feet x 3feet.2 The board frame should be made of MS Pipe 25x25x1.5 mm painted with one coat red oxide primer and 2 coat synthetic enamel paint.3 Top, Bottom and Side cover shall be made of 26 SWG GI sheet with powder coating and Back side of the board shall be covered with 26 SWG plain GI sheet fixed with rivet and screws.(b) Lighting/Illumination:1. Minimum one LEDtube light set is to be provided per five Square feet of board area.2. Complete tube light set is to be provided. Tube lights shall be of reputed make.3. Only copper wiring will be used.(c)Flex:1. Backlit Flex should be of LG Hi-Flex.2. Writing work etc. should be digitally printed. Printing details will be provided by the department.(d) Installation:1. No separate installation charge will be given. Glow Sign Boards are required to be installed at main entrance gate of Pump House all as directed with required supporting .2. Installation shall be done using MS Fabrication (Brackets, Flats etc.) and required PCC work (if reqd). |
| 95 | Fabrication, supply and installation of Sign Boards, single sided of hardened ACP sheet 3 mm thick , PoP riveted to stainless steel square pipe 20 mm x 20 mm and overall size of frame 900x1100 mm frame supported with another Frame made of 40 x 40 mm SS square pipe and 2.5 M long double legged stainless steel pipe 50 mm dia, 16 gauge (SS - 304 Grade) and fixed with each other with SS clamps.The board is fully reflectorised with high intensity grade retro reflective tape of any colour grade IV as per ASTM - D 4956-07 and lettering (any Nos) loc map white colour or as directed duly computerised cut including arrow, signs, logos etcfixed over retro reflective tape.Board to be fixed on ground 450 mm deep with necessary cement concrete complete all as specifed and as directed. |
| 96 | Preparing Old painted surfaces of LT panel inside oustside both, all exposed surfaces of steel items, without dismantling and M&L for painting complete all as specifed and dricted (a) preparation of old surfaces by cleaning, scrapping, rubbing/ polishing etc complete all as specifed and as dricted.(b) painting with two coats of synthetic enamel paint of approved make / quality all as directed at site. |
| 97 | Deduct schedule of credit amount Rs. 71,951.00 to be deducted during AOC |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail