Tender For Electrical Renovation Of Ayurveda Biology Lab In Room No. 01 And 02 At Ssis, Jnu-Jnu/Engg./11/2025-26, delhi-Delhi

Tender Notice

51985693
Tender For Electrical Renovation Of Ayurveda Biology Lab In Room No. 01 And 02 At Ssis, Jnu-Jnu/Engg./11/2025-26
Tender
Indian
Delhi
Delhi
18-11-2025

Tender Details

Tender For Electrical Renovation Of Ayurveda Biology Lab In Room No. 01 And 02 At Ssis, Jnu-Jnu/Engg./11/2025-26; 1 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required. 2 Group A 3 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. 4 3 x 1.5sq. mm 5 3 x 4 sq. mm 6 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 7 6 Module (200mmX75mm) 8 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box includingconnections but excluding modular plate etc. as required. 9 5/6 amps switch 10 Supplying and fixingof two module stepped type electronic fan regulator on the existing modular plateswitch box including connection but excluding modular plat etc. as required. 11 Supplying and fixing of following sizes of medium class PVCconduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 12 25 mm 13 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required 14 Providing and Fixing following rating and braking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connection etc. as required. 15 125 amp, 16 KA TP (Thermal Magnetic Type) 16 Supplying and Fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 17 Single pole 18 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 19 Supplying and making indoor end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required. 20 4 core X 35sq. mm (32mm) 21 Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) 22 36 watt 23 Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R- 407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).Inverter Type - Cooling only 24 1.5 TR with 5 Star BEE Rating 25 Supplying and fixing following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, with provision of 100 amps TP 16 KA MCCB as incomer, interconnection between incomer MCCB and bus bars etc. as required. 26 4way (4 + 12), Double door 27 S/I/T/C of U-PVC DLP adaptable trunking system of size 105mm x 50mm complete with suitable width flexible cover, base & cover joints, internal & external angles end caps, clips, separation partition complete as required. 28 S/F3 module cover plate on existing U-PVC DLP adaptable trunking system of size 105mm x 50mm for fixing of 15amp switch and 15amp socket etc. as required. 29 Supplying and Fixing following modular switch / socket on the existingU-PVC DLP adaptable trunking of approved makeincluding connections but excluding modular plate etc. as required 30 20 amps switch 31 6 pin 6/16 Amps Socket outlet 32 Supply& Layingof1100 volts rated aluminium conductor steel wire / strip armored XLPEpower cable of following sizes as per IS-7098 part-Iwith ISI marked on wall surfaceincludingtesting at manufacturer site etc complete as required. 33 4 core 35sq.mm Armoured Aluminium cable

Key Value

Document Fees
Refer document
Tender Value
INR 2.55 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail