Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 15-11-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 22-11-2025 |
| Sl. No. | Item Description |
| 1 | DESCRIPTION OF ITEMS |
| 2 | Demolition of cement concrete in ground floor,paving,roof nexc 15cm thick(below or above GL) complete all as specified and directed |
| 3 | M & L for 50mm thick cement concrete 1:3:6, type C-1, as in Plinth protection etc finished even & smooth without using extra cement including forming necessary joints 12 mm wide to the full depth of PCC at every 3 metre and at change in direction complete all as specified & directed. |
| 4 | M & L for 100mm thick cement concrete 1:2:4, type B-1 finished even & smooth without using extra cement complete all as specified & directed. |
| 5 | M&L for PCC 1:3:6 type C2 (using 40mm graded aggregate) in foundations, filling and mass concrete complete all as specified and as directed |
| 6 | M&L PCC 1:2:4 Type B1 (20mmgraded agg) aslintels upto 1.5m clear span, cills, steps; seismicand other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed as directed |
| 7 | Demolition of brick work, stone/boulder masonary built in cement mortar complete all specified and directed |
| 8 | M&L for Pre-cast cement concrete 1:3:6 type C-1 (using 20 mm graded stone aggregate) block masonry with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6,complete all as specified and directed. |
| 9 | Taking down cement plaster on brick or stone walls, of any description including raking out joints, hacking for key, scrubbing down with water, etc complete all as spfd and directed. |
| 10 | M&L 10mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces including finishing the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 11 | M&L 15 mm thick rendering in CM 1:4 on fair faces of brick work or concrete surface including finishing the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 12 | M&L for Preparing new plastered wall surfaces and applying two coat of oil emulsion distemper over primer over wall putty of 1mm thckness over plastered surface to prepare the surface even and smooth complete all as specified and directed. |
| 13 | M&Lthree coats of white wash on wall surfaces including prepration of new plastered surfaces complete all as specified and directed |
| 14 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed |
| 15 | M&L for non skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.08 sqm and not exceeding 0.18 sqm, in floors over and including 15mm thick screed in CM 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles complete all as spfd & directed |
| 16 | M&L for vitrified ceramic light shade tiles/outdoor tiles 8-12mm thick (square or rectangular) polished area of each tile not exc.0 .36 sqm in floor etc and shall be jointed in neat cement slurry and pointed in paste pigmented to tile shade complete laid over screed bed,rendering or bedding layer of mortar CM (1:6) 15mm thick all as specified and directed |
| 17 | M&L for vitrified ceramic light shade tiles/outdoor tiles 8-12mm thick (square or rectangular) polished area of each tile not exc.0 .36 sqm in skiritng etc and shall be jointed in neat cement slurry and pointed in paste pigmented to tile shade complete laid over rendering in CM (1:4) 10 mm thick all as specified and directed. |
| 18 | M&L for coloured ceramic tiles in vertical surface, 450x300/300x600x7-8mm thick set and jointed in neat sement slurry and pointed in white or colour cement to match over 10 mm thick plaster in CM 1:4 complete all as spfd & directed. |
| 19 | M&L for Chequered coloured cement concrete tiles 30cm x 30cm x 20 mm thick set, jointed and pointed in neat cement slurry with grey pigment cement and pigments in floor including 15 mm thick screed bed or bedding layer in CM 1:6complete all as specified and directed. |
| 20 | M&L Granite (of any type) tiles 16-20 mm thick machine cut bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing over and including 15mm thick screed in CM 1:6 etc complete all as specified and as directed. |
| 21 | Taking down chowkhats or frame nexc 1.5 sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed. |
| 22 | Taking down chowkhats or frame exc 1.5 sqm but nexc 4.00 sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed. |
| 23 | Taking down shutter exc 1.0 sqm but n exc 2.00 sqm each complete all as specified and directed. |
| 24 | S&F for mild steel framed wk as in doors or gates of angle iron or other section complete drilled for fixing of steel sheeting or other covering doors, etc to be prepared for hanging or sliding with & incl either hooks & hinges or steel hanging door fitting (exclusive of steel sheeting or other covering, running rails and slides) & hanging, also fastening & fixingFe-290, Gde-165 complete all as spfd & directed. |
| 25 | S&F 0.63 mm th Mild steel, plain, black sheet in wall cladding,steel gates and similar work, cut to size, holes punched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams,including bending or turning up, mitred angles, etc. as required complete all as spfd & directed. |
| 26 | S&F 35 mm th Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 27 | M&L for 2nd class hardwood, 35 mm thick glazed and skelton shutter, open rebated and prepared to receive glass, gauge, etc. devided into squares, with plain, chamfered or rounded , mitred and rebated shash bars any numbers, edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass etc; size of members of shutter as specified in SSR Part I, Sectioin 8clause 8.24(a); supplied and fitted to chowkhat complete all as specified and directed. |
| 28 | S&F forpowder coated anodised aluminium frame for doors, windows ventilator with one or more rebates including joining cleat for fixing etc , screws, hinges, brackets, dash fastners/rawl plugs etc. complete all as specified and directed.complete all as specified and directed. |
| 29 | S&F powder coated aluminiumdoor shutters, aluminium section weighing 0.55 Kg/m including necessary jointing cleats glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc complete all as specified and directed. |
| 30 | S&Fpowder coated Anodised aluminium window and ventilator shutters, side hung typewithout sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodisedaluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified complete all as specified and directed. |
| 31 | M&L fordouble action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel covr, governing pivo made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed. |
| 32 | S&F 100 mm Mortice lock,vertical type,size 100 mm complete all as specified and directed. |
| 33 | S&F Door closer hydraulically regulated,designation No. 2,aluminium die cast body universal type complete all as specified and directed. |
| 34 | S&F floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floors 150mm long all as specified and as directed. |
| 35 | M&L for 18-19mm thick medium density fibre board, exterior grade, fixed with screws to timber frame work all as spfd and directed. |
| 36 | S&F 3-6mm thick teak wood lipping fixed with nails to fibre board/particle board all as spfd and directed. |
| 37 | S & F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised (width of flaps 30mm) complete all as specified and directed. |
| 38 | S&F 40mm dia cupboard knobs fixed with nut, screw and washer of mild steel bright finished complete all as specified and directed. |
| 39 | S&F catch magnet for cupboard shuttercomplete all as specified and directed. |
| 40 | Hacking out old broken glass (any thickness, size, quality or descrption) from metal/wooden frame including punching or driling outold glazing pins/springs and providing new ones complete all as specified and directed. |
| 41 | S&F 4.80 mm thick sheet glass ordinary quality and glazing with oil putty/rubber packing in square exc .50 sqm in each panels complete all as specified and directed. |
| 42 | S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty/wooden beads in square n.exc .50 sqm in each panels complete all as specified and directed. |
| 43 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 44 | S&F in repair Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 45 | S&F 100 mm mild steel but hinges medium weight,cold rolledcomplete all as specified and directed |
| 46 | S&F 150 mm aluminium handles, cast type anodisedcomplete all as specified and directed. |
| 47 | S&F150 mm aluminium anodised barrel tower bolts extruded section complete all as specified and directed |
| 48 | S&F 250mm long Aluminium alloy, anodised, sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed |
| 49 | S&F 150 mm Mild Steel barrel tower bolts, stove enamelled, black with bright bolts complete all as specified and directed |
| 50 | S&F 250mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed |
| 51 | S&F 200-300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed |
| 52 | Dismantling mild steel work of any description and in any position complete all as specified and as directed. |
| 53 | S&F roof trusses (framed), trussed, purlins, crane gantries, rails and gastenings and heavy brackets framing (beam, tee, angle channel or flat sections) (Fe-290 Gde E-165) inicluding distance pieces, cleats etc complete all as specified and directed. |
| 54 | S&F in repairs vitreous china wash basin,white flat back size 550X400mm incl 32mm size brass chromium plated waste fittings,waste pipe and brackets fixing in position complete all as specified and directed. |
| 55 | S&F in rep vitreous china squatting pan \"Orissa pattern\" size 580 mm x 440 mm white with integral foot rests, incl provn of lime concrete bedding complete all as spfd & directed. |
| 56 | S&F in repair Vitreous China Wash down water closetEWC with plastic seat cover complete all as specified and as directed . |
| 57 | S&F in repair Vitreous China Rimless Single Piece WC min. size 370x665x750 mm With PP Soft Close Slim Seat Cover, Hinges, Dual Flush Cistern Fittings, incl Fixing Accessories and Accessories Set and necessary trap complete all as specified and as directed . |
| 58 | S&F in repair sinks made of stainless steel 1 mm th kitchen or laboratory with plugs, washers & waste coupling, incl bedding in CM to dwarf wall or incl fixing cantilever brackets & connecting union to pipe over all size 495x420mm bowl size 410x330 mmx160 mmcomplete all as spfd & directed. |
| 59 | S & F in repair sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs washers and wastes including bedding in cement mortarto dwarf wall or including fixing cantilever brackets and connection union to pipe overall size 914 mm x 460 mm ,bowl size 405 mm x 354 mm complete all as specified and directed. |
| 60 | S&F for PVC low level flushing cistern 10ltr capacity, with cyphonic, action PVC float valve, brackets and 32mm bore PVC flush pipe etcas spd and fixed in repair all as specified and directed |
| 61 | S&F in repair Tubular towel rail brass chromium plated 20mm dia, D type, 60cm long between flanges complete all as specified and directed |
| 62 | S&F in repair CP Towel Ring fixed with and including Chromium plated brass screws and cleats complete all as specified and directed |
| 63 | S&F in repair 15mm bore Chromium plated Bib taps fancy type, cast copper alloy screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 64 | S&F in repairsstop valve/angle valve, bore of dia 15mm of Chromium plated fancy type cast copper alloy screwed down for iron pipe and fixed etc complete all as specified and directed. |
| 65 | S&F in repairs Brass CP mixer fancy type for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed. |
| 66 | S&F 15mm Pillar taps, cast copper alloy,fancy type, chromium plated, screwed down high pressure, with or without lettered ‘Hot\" or ‘Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed in repairs complete all as spfd & directed. |
| 67 | Supply only 15mm pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot\" or ‘Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe complete all as spfd & directed. |
| 68 | S&F in repair 15mm dia cast iron bib taps with forged brass stem & brass jumper valve, screwed for iron pipe and fixed all as specified and directed |
| 69 | S&F in repairs Stainless steel soap dish, any type fixed to plugs with chromium plated brass screws complete all as specified and directed. |
| 70 | S&F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 71 | S&F in repairs plastic water closet seat, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging devise complete all as specified and directed. |
| 72 | M&L for32mm in size Waste fittings, brass, chromium plated for stainless steel sinks, glazed ware basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed in reapirs complete all as specified and directed |
| 73 | S&F PVC connections 15 mm size with PTMT nuts of length 600mm long fixed in repairs all as spfd and as directed. |
| 74 | S&F in repairs PVC waste pipe 32/40mm dia for wash basin/kitchen sink/urinals complete all as specifiedand as directed. |
| 75 | S&F in repair 20 mm bore Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed all as specified and directed. |
| 76 | S&F in repair 15 mm bore Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed all as specified and directed. |
| 77 | S&F in repairs Brass chromium plated shower rose 125mm sizeincluding shower arm of min. 30 cm length complete all as spfd & directed |
| 78 | S&F in repairs shower concealed stop valve, bore of dia 15mm of Chromium plated fancy type cast copper alloy with long shank and capstan head for (Bath shower) screwed for iron pipe and fixed including making good exisiting surfaces complete all as specified and directed. |
| 79 | S&F 15 mm bore GI tubing with all fittings medium grade fixed to wall or laid in floor etc including taking up or down 15 mm GI tubingcomplete all as spfd & directed |
| 80 | S&F in repairs Health Faucet (ABS Body) MS, Chromium platedsuitable for 15mm dia pipe with 1.25 mtrlong flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed. |
| 81 | S & F in repair Harrison rails/curtain rods, mild steel, chromium plated with brackets,stops, rollers etc fancy type as approved complete all as specified and directed. |
| 82 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers fixed in repairs complete all as spfd & directed. |
| 83 | Supply and fix 1000 Ltr rotational moulded polyethylene water stotage tanks triple layered ( cylinderical vetrticle with closed top) hoisted & fixed in position including dismantlling old water tank, complete all as specified and directed. |
| 84 | Supply and fix 500 Ltr rotational moulded polyethylene water stotage tanks triple layered ( cylinderical vetrticle with closed top) hoisted & fixed in position including dismantling old water tank complete all as specified and directed |
| 85 | S&F in 20 mm bore Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed all as specified and directed. |
| 86 | S&F in repair 15mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 87 | S&F in repair 20mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 88 | Supply and fix in repairs CP Wall Mixer with provision for Overhead Shower with 115mm Long Bend Pipe on Upper Side, Connecting Legs & Wall Flanges for 15mm dia pipe complete all as specified and directed |
| 89 | S&F in repairs PVC acrylic toilet cabinet mirror appx size 622mmx422mm with shelves, shutter and mirror complete all as specified and directed. |
| 90 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness including cover fillets,fittings etc. complete all as specified and directed. |
| 91 | S&F False Ceiling Horizontal level regular edge grid 600 x 600 mm form work using hot dip sections and fixing tiles vinyl laminated MPL gypsum panels size 595x595x6 to 8mm thick after lamination, suspended the grid with grid hangers to Roof Truss / RCC Slab complete all as specified and directed. |
| 92 | S&F 5 to 8mm thick PVC hollow type wall panellingany color fixed to wall/ceiling with L or U shaped beading at ends fixed with screws complete all as specified and as directed. |
| 93 | M&L for 6mm thick Plywood, grade BWR, type BB, fixed in ceiling/ walling with screws to timber frame work complete all as sfd and directed. |
| 94 | M&L II nd classhard wood plain fillets square or rectangular in section cleansawn but bullnosed chamfared or rounded on one edge or face sectional area exc 3 sqcm and nexc 6 sqcm secured in nails complete all as specified and directed |
| 95 | Dismanteling of timber scantling 40 sqcm and over in section in any position for unframed workscomplete all as specified and directed |
| 96 | M&L for 2nd class hard wood as in scantling clean sawn framed & fixed as in ceiling and walling wks, complete all spfd & directed. |
| 97 | Dismantling of timber scantling 40 Sqcm under in section in any position, fixed with nails unframed work complete all as spfd & directed. |
| 98 | M&L for II nd classhard wood plain fillets squaree or rectangular in section clean sawn secured with nails sectional area exc 13 sqcm and n.exc 25 sqcmcomplete all as specified and directed |
| 99 | M&L for one coat of creasote oil to wooden surfaces new or old of any description including prepration of surfaces complete all as specified and directed. |
| 100 | Dismantling of plain or corrugated steel sheeting of any guage/thickness in roof covering/wall clading complete all as spfd and directed |
| 101 | S/F 0.63 mm th galvanised corrugated mild steel sheeting with two corrugation side lap fixed with \"L\" type or \"J\" type or cranked hook bolts fixed to roof covering/cladding to wall complete all as spfd & directed |
| 102 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 103 | S&F pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 104 | M&L for two coat of synthetic enamel paint overa coat of pink primer to new/old wooden surface of any description exc 10 cm girth or width including prepration of new/old wooden surfaces complete all as specified and directed |
| 105 | M/L for two coats of synthetic enamel paint over a coat of red oxide primer to steel surfaces of any description over 10 cm in width or girth incl preparation of new steel surfaces complete all as spfd and directed. |
| 106 | M&L for Preparing old surfaces, plastered or unplasterd old decorated wall surfacesandapplying two coat of oil emulsion distemper over a coat of wall putty of 1mm thckness over plastered surface to prepare the surface even and smooth complete all as specified and directed. |
| 107 | M&L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less that 50gm/liter and UV resistance as per IS-15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 liter / 10 Sqm over and includingpriming coat of exterior primer applied @0.90 liter/10 Sqm over a coat of wall putty 1mm thick over old surfaces including complete removal of exisiting treatment complete all as specified and directed. |
| 108 | M & L for one coat of white wash on old decorated wall surfaces including preparation all as specified and directed |
| 109 | M & L for one coat of white wash on old decorated ceiling surfaces including preparation all as specified and directed |
| 110 | M & L One coat of Oil bound distemper on old decorated wall surfaces including preparation all as specified and directed |
| 111 | M & L one coat of Cement based painton old decorated wall surfaces including preparation all as specified and directed |
| 112 | M & L for preparation of old decorated steel surfaces andapplying one coat of synthetic enamel paint complete all as specified and directed. |
| 113 | M & L for preparation of old decorated wooden surfaces andapplying one coat of synthetic enamel paint complete all as specified and directed. |
| 114 | M&L cleaning of existing septic tank and sewage well by closing the existing sewage system at last man hole. Removing man hole cover and dewatering the liquid waste by mechanical pumping. Removing the solid sludge by manually or by mechanical system up to the bottom of septic tanks and sewage well at any sizeincl depositing the solid sludge in the pit providing by digging in near by septic tank of appropriate size. Whole area to be covered with bleaching powderand covered by natural earthobtained from excavation after filling the solid sludge and makinggood completely hygienic and directed at site. Note: During the cleaning of soakage wells/septic tanks, alternate arrangement be made by contractor by temporary pumping arrangement for clearing continuous incoming sewage complete all as specifed and directedNote :-(i) The cost of excavation ofpit, bleaching powder and RFR to cover the sludge shalldeemed to be inclusive in rate quoted by the contractor.(ii) All the tools and plants including mechanicalpump and other allied arrangements for making sewage line functional will be made available by the contractor with out any extra cost to the Govt. |
| 115 | S&F On site coventional LLDPE septic tank capacity of total capacity 3000 ltr designed to carry sewage and sullage water, incl excavation in any type of soil, 100mm th PCC 1:4:8 below foundation, Vent shaft, connection etc., complete all as specified and directed. |
| 116 | Construction of Soakage well incl excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.20m dia and 3.0m effective depth all as per CEBZ TD/309 SHT-1/4 to 4/4 complete all as specified and directed. |
| 117 | Dismantling of 200 mm dia cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed. |
| 118 | S&F reinforced concrete pipes, class NP2, 200mm laid and jointed complete with collars, complete all as specified and directed. |
| 119 | M&L for concrete bed 1:4:8 type D-2 (Using 40 mm graded stone aggregate) as in drain pipes including packing under, and haunching against the side of pipes after the are laid and tested in 200 mm bore pipe, complete all as specified and directed. |
| 120 | Cutting into existing manholes for connecting new drains, of any dia making good to pipe and rendering , cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in cement concrete (1:2:4 ) type B1 using 20mm graded crushed stone aggregate finished smooth and reforming benching as required for 200 mm dia pipe complete all as specified and directed. |
| 121 | Excavation in trenches in hard/dense soil n.exc 1.50 m deep and1.50m wide or shafts, manhole etc n.exc 10 Sqm on plan and n.exc 1.50m deep and getting out complete all as specified. |
| 122 | Returning, filling in trenches, including spreading, leveling watering and wall ramming in layers each n.exc 25cm in hard/dense soil complete all as specified and directed. |
| 123 | Removal of surplus spoil to a distance n.exc 50m and depositing where directed at a level n.exc 1.50 m above the starting point complete all as specified and directed. |
| 124 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed. |
| 125 | M&L for pre-cast reinforced cement concrete as in cover slabs (1:2:4) type B1 using 20mm graded stone aggregate complete after placing in position over septic tanks/ manhole covers set in CM 1:6 etc complete all asspecified and directed . |
| 126 | M&L for MS TMT bars 10 mm dia and over cut to length, bent to shape including cranking bending, andbinding with MS wire (annealed) not less than 0.9 mm dia complete all as specified. |
| 127 | E&M |
| 128 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc and making good disturbed surfaces of walls, floors etc. complete all as specified. |
| 129 | M & L point wiring with 1.5 Sqmm (Nominal cross sectional area) single core PVC insulated with PVC unsheathed multi stranded copper conductor cable in PVC concealed /surface conduit 20mm or higher dia/ capping & casing , complete with all accessories /fitting in sunken terminal boxes modular /non modular ( terminal box should be of PVC heavy duty /GI )with suitable size with 3 mm thick plastic laminated hard gloosy surface sheet top cover / modular sheet cover in case of modular sunken box .openrecessed on all and brass screw and washer/ including modular top cover sheet ,including unsheathed single core PVC insulatedcable green in colour 1.5 Sqmm multistranded copper conductor as contineous earth wire and connecting to earth dolly includingmakinggood disturbed surfaces to same as previous existing complete all as specified for one light /fan /bell point controlled by one way switch of 5/6 Amps. |
| 130 | ditto as per item No 128 above but for one 3/5 pin socket outlet point on same board controlled by one way switch of 5 Amps |
| 131 | ditto as per item No 128 above but for one 3/5 pin socket outlet point on independent boardcontrolled by one way switch of 5 Amps |
| 132 | M & L point wiring with 2.5 Sqmm (Nominal cross sectional area) single core PVC insulated with PVC unsheathed multi stranded copper conductor cable in PVC concealed /surface conduit 20mm or higher dia/in caping casig , complete with all accessories /fitting in sunken terminal boxes modular /non modular ( terminal box should be of heavy duty PVC/GI )with suitable size with 3 mm thick plastic laminated hard gloosy surface sheet top cover /modular plate with frame open recessed on all and brass screw and washer/ including modular top cover sheet ,including unsheathed single core PVC insulatedcable green in colour 2.5 Sqmm multistranded copper conductor as contineous earth wire and connecting to earth dolly includingmakinggood disturbed surfaces to same as previous existing complete all as specified for one light /fan /bell point controlled by one way switch of 5/6 Amps. |
| 133 | S&F switch piano flush button single pole two way 5/6 Amps complete all as specified. |
| 134 | S&F switch piano flush button single pole two way 5/6 Amps complete all as specified. |
| 135 | S&F bell push flush button single pole one way 5Amps complete all as specified. |
| 136 | S&F switch piano flush button single pole one way 15Amps complete all as specified. |
| 137 | S&F socket out let 3 pin 5/6 Amps flush type complete all as specified. |
| 138 | S&F socket out let two in one 3 pin 5/6 Amps and 3 pin 15/16 Amps,flush type, non shutters, non interlocking complete all as specified. |
| 139 | S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and directed. |
| 140 | Supply & fixing in replacement of modular switch one way 06 Amps,1 module,240 volts complete all as specified & directed |
| 141 | Supply & fixing in replacement ofmodular socket one way 6 Amps,2/3 pin combined ,2 module,240 volts complete all as specified & directed |
| 142 | Supply & fixing in replacement of modular switch one way16 Amps,1 module, 240 volts complete all as specified & directed. |
| 143 | Supply & fixing in replacement ofmodular socket one way 6/16 Amps,2/3 pin combined ,2 module,240 volts complete all as specified & directed. |
| 144 | Supply & fixing in replacement ofmodular Bell Push 6A,(1 or 2 module as per site), 240 volts complete all as specified & directed. |
| 145 | Supply & fixing in replacement ofmodular Two way switch 6A,(1 or 2 module as per site), 240 volts complete all as specified & directed. |
| 146 | Supply and fixingModular steped type electronic fan regulator 2 module on the existing sheet etc. AC, 230 volts, duly ISI marked with and including connector complete all as specified & directed by Engineer-in-Charge. |
| 147 | Supply and fixing modular blanking /dummy Plates 1 M. |
| 148 | Supply & fixing in replacement ofmodular white cover plate with frame includingPVC Sunken box ,3 module for6 / 16 Amps Switches ,240 volts complete all as specified & directed |
| 149 | Supply & fixing in replacement ofmodular white cover plate with frame includingPVC Sunken box ,4 module for6 / 16 Amps Switches ,240 volts complete all as specified & directed . |
| 150 | Supply & fixing in replacement ofmodular white cover plate with frame includingPVC Sunken box ,6 module for6 / 16 Amps Switches ,240 volts complete all as specified & directed . |
| 151 | Supply & fixing in replacement ofmodular white cover plate with frame includingPVC Sunken box ,8 module for6 / 16 Amps Switches ,240 volts complete all as specified & directed . |
| 152 | S&F Ceiling rose, surface bakelite, AC, 60x30mm, 3 terminals complete all as specified and directed. |
| 153 | S&F lamp holder PVC/poly carbonated typewith back plate suitable for pendants /angular /batten fittings complete all as specified and directed. |
| 154 | S&F in replacemnt of Bell multi music type complete all as specified and directed. |
| 155 | S&F sheet metal enclosure for DB SPN 2 way 240 Volts, single door suitable for housing MCBs and isolators complete all as specified. |
| 156 | S&F sheet metal enclosure for DB SPN 4 way 240 Volts, Double door suitable for housing MCBs and isolators complete all as specified and directed |
| 157 | S&F sheet metal enclosure for DB SPN 6 way with 200 Amp rated bus bar 240 Volts, Double door suitable for housing MCBs and isolators complete all as specified and directed |
| 158 | S&F sheet metal enclosure for DB SPN 8 way with 200 Amp rated bus bar 240 Volts, Double door suitable for housing MCBs and isolators complete all as specified and directed |
| 159 | S&F sheet metal enclosure for DB SPN 12 way with 200 Amp rated bus bar 240 Volts,double door suitable for housing MCBs and isolators complete all as specified. |
| 160 | S&F sheet metal enclosure for DB TPN 4 way with 200 Amp rated bus bar 415 Volts,double door suitable for housing MCBs and isolators complete all as specified. |
| 161 | Supply and fixing Vertical Loadline sheet metal enclosure double door, Triple pole and neutral (TP&N vertical loadline) AC, 415 volts, 04 way, with 200 Amps rated copper bus bar and IP - 43 & IK 09 protection, with the inbuilt provison forfixing of 1 No MCCB of XT1160 frame suitableupto 160 Amp and 12 Nos MCB\"S inside of DB,including 100 Amps ,25 KA 4 pole MCCBwith metal door and flush to wall/fixed on wall surfce including grouting and cutting in existingwall and making good disturbed surfacewith two coats of white / colour washing / distempering etc to match the existing one complete all as directed by Engineer - in - Charge. |
| 162 | Supply & fixingin repair industrial type SPN enclosure with a two pin and earth plug and socket complete with and including 20 Amps MCB, single pole, AC, 240 volts and flush to wall including all cuttings & chases etc on wall of fixed on surface of wall and making good including two coats of white / colour washing / distempering etc to match the existing disturbed surfaces complete all as directed . |
| 163 | S&F MCB SP 6-32 Amps, 240volts 10KA complete all as specified and directed. |
| 164 | S&F MCB SPN 32 to 63Amps, 240volts 10KA complete all as specified and directed. |
| 165 | S&F MCB 4 pole32 to 100 Amps, 240volts 10KA complete all as specified. |
| 166 | Material and labour for sub main wiring with 2x6 Sqmm nominal cross sectional area (two single core cable of 6 Sqmm for Phase and neutral + o1 single core cable of 6.0 Sqmm for earth wire), 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor cable with and including continuous earth wire of size 6.0 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metallic PVC concealed /surface conduit of 25 mm dia, medium grade with all conduit accessories / fittings, brass screws, washers etc and connected to common earth dully including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existingand taking down the old unserviceable submain wiring of ant type complete all as specified & directed.( Note - One meter of conduit along with 2x6.0 Sqmm wire and one 6.0 sqmm earth wire shall be measured as one length). |
| 167 | Supply and fixing LED lights fitting integrated1x 20W, 220V, AC ,Approx 4 feet size decorative box type with driver connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified. |
| 168 | Supply and fixing LED lights fitting integratedwarm white1x 20W, 220V, AC ,Approx 4 feet size decorative box type with driver connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified. |
| 169 | Supply and fixing LED lights fitting mirror type with high out put diffuser 2 feet,1x 10W, 220V, AC decorative box type with driver, holder including LED tube light, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified. |
| 170 | S&F LED bulb 12 watts, 220V complete all as specified. |
| 171 | Supply and fixing LED luminaire 600 mm x 600 mm panel, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver,suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified. |
| 172 | Supply and fixing LED luminaire 600 mm x 600 mm panel warm white, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver,suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 173 | Supply and fixing LED Bulk head10 watt IP 65/66 all as specified and directed. |
| 174 | Supply and fixing Decorative, wall mounting, brushed nickel finish fixture with Opal Glass diffuser suitable with 9 W LEDlamp B22 base complete all as specified and directed. |
| 175 | Supply and fix 5W Aluminium Flexible Wall Reading Lights with On Off Switch ,Gooseneck Light - 360° Lighting complete all as specified and directed. |
| 176 | Supply and installed LED security light fitting 1x35 Watt luminaries with pressure die cast aluminium housing , with lenes embeded ,IP-66/IP 65 Protection complete all asspecified and directed. |
| 177 | supply and fixing GI bracket made out of 0.9-1.2 mtr GI pipe bent to shape light grade of 25to 40 mm dia, bracket mounting clamps nut bolts etc all as specified and directed. |
| 178 | Supply and fixinf post Top Lantern 25 wattt ,IP 65 including all accessories ti fixingall as specified and directed. |
| 179 | Supply and fixinf post Top Lantern 15 wattt ,IP 65 including all accessories ti fixingall as specified and directed. |
| 180 | Taking down and servicingceiling fan from existing position, dismantling, overhauling and cleaning throughly, oiling /greasing and re- assemble after replacing split pins, check nuts, rubber seal etc and rehanging at same or new locations duly connected with new PVC three core flexible copper conductor cable of size 23/.0076, complete testing & specified.Note: Spare parts will be measured and paid separately under respective items as supply only as mentioned below. |
| 181 | Refixing of ceiling fan including fixing blades and making connection all as specified and directed. |
| 182 | M&L for taking out burnt copper winding from ceiling fan of 1200 mm size and rewinding with existing /same guage of super enammeled copper winding wire complete all as specified. |
| 183 | Supply only Ball bearing for Ceilingfan after and including taking down old ball bearing complete all as reqd at site, specified. |
| 184 | Supply only capacitor 2.5 mfd±5%, 440 Volt, AC, 50Hz after removing old defective condensor complete all as specified. |
| 185 | Supply and fixing ceiling fan stator with copper winding as all as specified and directed. |
| 186 | Taking down exhaust fan of any size from existing position, dismantling, overhauling and cleaning throughly, oiling/greasing and re- assemble after replacing unsv parts etc and rehanging the same duly connected with new PVC three core flexible copper conductor cable of size 23/.0076, complete testing & specified.Note: Spare parts will be measured and paid separately under respective items as supply only as mentioned below. |
| 187 | M&L for taking out burnt copper winding from exhaust fan of any size/type and rewinding with existing /same guage of super enammeled copper wire complete all as specified. |
| 188 | Supply and fix exhaust fan PVCmotor suitable for 200 to 300 mm sweep exhaust fan Copper windingall as specidfied and directed |
| 189 | Supply only capacitor 1-1.5 mfd±5%, 440 VAC, 50Hz Suare shape suitable for PVC body exhaust fan 200/250mm sweep or suitable one after removing old defective capacitor complete in exhaust fan all as specified. |
| 190 | Supply only capacitor 4 mfd±5%, 440 Volt, AC, 50Hz or suitable one after removing old defective capacitor complete in exhaust fan all as specified. |
| 191 | Supplyand fixing motor of metalexhaust fan 300mmcopper wounded all as specified and directed. |
| 192 | Supplyand fixing motor of metalexhaust fan 450 mm,1400 RPM copper wounded all as specified and directed. |
| 193 | Supply and fix exhaust fan PVCcomplete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m all as specidfied and directed |
| 194 | Taking down flate-plate solar collector storage solar water heater of capacity upto 250ltr, dismantling inner tank and outer tank, pipe assembly, cleaning thoroughly with descaling liquid compound complete to ensure free and constant flow of water through outlet, welding of inner tank if required at site, laser/ultrasonic welding for bonding fin and raiser tube, repair of copper bracing for bonding of header and raiser making leak proof, repair & repalcement of back and side insulation material, rethreading of inlet/outlet pipe 20 mm dia, reassembling the same after replacing u/s items i.e. heating element, thermostete, toughned glass, connection pipe with clamp etc. at existing location including necessary fasteners to ensure proper safety as reqd at site, repair/welding of MS structure for collector stand, testing and commissioning after re-installation at site complete all as specified.Note: Spare parts (heating element, thermostete, toughned glass, connection pipe with clamp) will be measured and paid separately under respective items as supply only as mentioned below. |
| 195 | Supply only heating element of 3.0 KW for solar water heater (as per sample ISI brand) including taking down old heating element complete all as specified. |
| 196 | Supply only thermostate for solar water heater. |
| 197 | Supply only Heavy duty nylon threaded flexible PVC/CPVC connection pipe 25 mm dia suitable for both hot & cold watrer supply of solar water heater complete all as specified. |
| 198 | Material and labour for sub main wiring with 2x4 Sqmm nominal cross sectional area (two single core cable of 6 Sqmm for Phase and neutral + o1 single core cable of 4.0 Sqmm for earth wire), 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor cable with and including continuous earth wire of size 4.0 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metal lic PVC concealed /surface conduit of 25 mm dia, medium grade with all conduit accessories / fittings, brass screws, washers etc and connected to common earth dully including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existingand taking down the old unserviceable submain wiring of ant type complete all as specified & directed.( Note - One meter of conduit along with 2x4.0 Sqmm wire and one 4.0 sqmm earth wire shall be measured as one length). |
| 199 | Taking down carefully storage water heater/Geyser of capacity 25/35/50 ltr, dismantling pipes assembly, cleaning thoroughly with descaling liquid compound complete to ensure free and constant flow of water through outlet, incl taking out unsv thermostate, haeting element or PVC connection pipe, reassembling the same at existing /new location including necessary fasteners to ensure proper safety as reqd at site, testing and commissioning after re-installation at site complete all as specified and directed.Note: Spare parts will be measured and paid separately under respective items as supply only as mentioned below. |
| 200 | Supply only thermostate fitting fitment varying capacity for 25/35/50ltrs capacity geysers. |
| 201 | Supply only PVC connection pipe nylon threaded 15mm size with brass nuts copping in both end of length 600mm for geysers complete all as specified and directed. |
| 202 | Supply only heating element of 1.5/2.0 KW for geyser (as per sample ISI brand) including taking down old heating element complete all as specified and directed. |
| 203 | S&F in replacement stop valve 15mm dia cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or union complete all as specified. |
| 204 | Suppy andFixingChargeble LED Bulb9B 22 watt having backup minimum three hours complete all as specified and directed. |
| 205 | Material and Labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick, buried directly in ground (earth pitnot less then 2.25 metres deep below ground level) with top edge of the plate not less then 1.5 metres below normal ground level, conneted to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, cheek nuts and washers of galvanised oriron protected by 15 mm bore GI pipe (medium grade) and connected to main switch board as directed including concrete pit in PCC (1:3:6) type C1 precast RCC (1:2:4) type B1 cover slab 40x40 Cm x 6Cm reinforced with 8 mm dia deformed bar @ 5 cmc/c with one handle for lifitting made out of 8 mm dia MS bar, funnle, wire mesh, 20 mm bore GI pipe (medium grade) for watering including charcoal and salt in alternative layers necessary excavation and earth work in any type of soil and testing complete all as shown on electrical plate No-3 of SSR part-I, 2009. |
| 206 | Disconnecting all electrical and copper pipe connection and taking down carefully split type AC of 1.5TR rating from existing position, dismantling, servicing, overhauling and cleaning of filters, fans, indoor and outdoor units through washing or air pressure throughly, checking cooling coil, compressor, gas level, oiling and greasing of fan & motor etc and re install at same ocations after replacing defective parts duly connected with existing AC supply complete all as specified and directed. Make : LG Note :-1-Spare parts shall be measured and paid separately under respective item of BOQ. 2 - Service will be done at the site will consider only one time if machine will become unserviceable after service but spare parts will be cosidered. |
| 207 | Supply and fixing starting capacitor and running cacacitor of 40 to 60MFD complete all as specified & directed by Engineer-in-Charge. |
| 208 | Supply and fixing running cacacitor of 20 to 36MFD complete all as specified & directed by Engineer-in-Charge. |
| 209 | Supply and fixing starting relay suitable for window type AC for any Capacity complete all as specified & directed by Engineer-in-Charge . |
| 210 | Supply and fixing condensor coil for 1.5 ton/ 2 Ton window type AC/ Split Type AC complete all as specified & directed by Engineer-in-Charge |
| 211 | Supply and fixingAir filtermade of PVC/Nylon fiber suitable for 1.5 / 2 Ton split type AC complete all as specified & directed by Engineer-in-Charge. |
| 212 | supply anf fixingcopper wounded compressor fan motor /inddor unit fan motor suitable sizefor air conditionsers 1.5 / 2 Ton capacity as per site requirement all as specified and directed by Engr-in charge |
| 213 | supply and fixing indoor unit suitable for split type air conditioner of capacity 1.5/2 Tonsuitable for any existing make either for invertor type/ non inverter type, 5 star rated complete all as per site requirement including all fixing accessories complete all asspecified and directed by Engr-In -Charge. |
| 214 | Taking down carefuly the hermetically sealed /Rotarycompressor unit from window type/Split type Air conditioner 1.5 ton and replacing it with new receprocating /rotary/Scroll type as per site requirementandgas charging complete in all respect and testing at required pressure after re-installing at site including replacement of mounting rubber bushes, nut bolts etc and testing after installation of following capacities of compressors.Note : Gas charging with refrigerant R-22 of Air conditioner will be measured & paid separately under relevant item. (a) 1.5/2 tonTon.MAKE- KIRLOSKAR/EMERSON/GMCC/Whirlpool/Tecumseh/LG |
| 215 | supply and fixing outdoor unit with copper condenser,rotary compressor 230 volt , 50HZ suitable for split type air conditioner of capacity 1.5/2 Ton suitable for any existing make either for invertor type/ non inverter typecomplete all as per site requirement including all fixing accessories complete all asspecified and directed by Engr-In -Charge.Whirlpool/LG/Hitachi/Godrejor existing make. |
| 216 | Supply & fix in replacementmetal plug top 20 Amps for ACcomplete all as specified and directed by Engineer-in-Charge. |
| 217 | Material and labour for Charging of Refrigerant R32/R-314 or anyother latest refrigerant as per site requirement in AC with required quantity, testing flushing complete system against leakage etc complete all as specified & directed.make-Mefron/Floron/Refron |
| 218 | supply and fixing PCB for Indoor UNIT ofair conditionersuitable for 1.5/2 TON ACas per site requirement complete allas specified and directed. |
| 219 | Labour only for servicing of Refrigerator or Deep Freezer incl repacement of unserviceable spare parts complete including commissioning and testing after installation at site complete all as specified and directed.Note : Spare parts shall be measured and paid seperately. |
| 220 | Supply and fixing starting/over loadrelay suitable for any type and capacity of refreigerators/Deep freezer/water complete all as specified and directed by Engineer-in-Charge. |
| 221 | Supply and fixing thermostat switch with knob suitable for any type of refreigerators/Deep freezer complete/water cooler all as specified and directed by Engineer-in-Charge. |
| 222 | Supply and fixing freezer assembly suitable for any capacity and make of refrigerators complete all as specified and directed by Engineer-in-Charge. |
| 223 | Supply and fixing motor suitable for refrigerators/Deep freezer/water cooler of any capacitycomplete all as specified and directed by Engineer-in-Charge/GE. |
| 224 | Taking out carefuly the old compressor formrefrigerators /deep freezerand fixing new rotary compressorand gas charging complete in all respect and testing at required pressure incl replacement of mounting rubber, bushes nut bolts etc and testing after installation. Make:- LG/Tecumseh/Emerson/Whirlpool or as per make available at site Note : (i) Gas charging with refrigerant R-134 A of Refrigerator will be measured & paid for separately under respective item of BOQ. |
| 225 | M&L for gas charging with suitable Refrigerant Gas R-134a after cutting/opening sealed unit (compressor) of water Cooler /Refrigerator /Deep freezer of any size/capacity/type including replacement of capillary pipe and moisture driver filter etc including crimping and re soldering to charging line after gas charging complete all as specified and directed. |
| 226 | Supply and fixing PCB for refrigerator of grosss capacity from 165 to 300 Ltrs suitable for all as per site requirement completall as specified and directed by Engr-In-Charge. |
| 227 | Labour only for servicing of self container drinking water cooler storage capacity upto 150 ltrs, dismantling inner tank and outer tank, pipe assembly, cleaning throughly with descalling liquid compound, overhauling complete to ensure free and constantflow of water through outlet, rethreading of inlet pipe 15 mm dia, thorough checking/ rectification of fault in electrical circuits and refrigeration system, replacement of compressor or other necessary parts as required, reassembling the same at existing/new location including necessary fasteners to ensure proper safety as reqd at site, testing and commissioning after re-installation at site complete all as specified and directed.Note: Spare parts shall be measured seperately and paid under relevent items as supply only. |
| 228 | Supply and fixing starting capacitor of suitable capacityfor water cooler 40/80 and 150/150 capacitycomplete all as directed by Engineer-in-Charge. |
| 229 | Supply and fixing drain pipe of water coolers of size not less than 25 mm in dia, superior quality complete all as directed by Engineer-in-Charge. |
| 230 | Supply and fixing running capacitor of requird capacityfor water cooler 40/80 and 150/150 capcity complete all as directed by Engineer-in-Charge. |
| 231 | M&L for taking out carefuly the hermetically sealed defective compressor from water cooler 40/80 ltrs and refixing it after repair with factory repaired from the authorised dealer and gas charging complete in all respect and testing at required pressure incl replacement of mounting rubber, bushes nut bolts etc and testing after installation. Make -TECUMSEH/Emerson/LG/Whirlpool/Kirloskar or as per site Note : (i) Gas charging with refrigerant R-22/ 314A of water cooler will be measured & paid for separately. |
| 232 | Material and labour for rewinding of burnt transformer using super enamel copper wire of existing size as directed by EIC for the following capacity of voltage stablizers. Note :- Spare parts shall be measured and paid separately under respective item of BOQ(a) 5/4 KVA cap of any make. |
| 233 | All as per item no 231 above but capacity 1/2 KVA capacity. |
| 234 | supply and fixing plug 3 pin 15/16 Amp suitable at site complete all as specified and directed. |
| 235 | supply and fixing plug 3 pin 5/6 Amp suitable at site complete all as specified and directed. |
| 236 | supply only Tape roll 10 meter long ,17 mm width for electrical work all as specified and directed. |
| 237 | supply and fixing PVC board with 15 /16 amp switch and sockets fixed in the board completeall as specified and directed. |
| 238 | supply and fixing PVC board with 5/6 Amp switch and sockets fixed in the board completeall as specified and directed. |
| 239 | supply and fixing PVC board with two 5/6 Amp switch and two 5/6 amp sockets fixed in the boardall as specified and directed. |
| 240 | supply and fixing bed holderall as specified and directed. |
| 241 | supply and fixing bed switchall as specified and directed. |
| 242 | supply and fixing MCCB 4 Pole, 415 V, Adjustable type, 250 Amps all with breaking capacity 36 KA all as specified and directed. |
| 243 | supply and fixing Changeover switch 32 Amp three phase with enclosureall as specified and directed. |
| 244 | supply and fixing Changeover switch 63 Amp three phase with enclosureall as specified and directed. |
| 245 | Material and labour for sub main wiring with 2x1.5 Sqmm nominal cross sectional area (two single core cable of 1.5 Sqmm for Phase and neutral + o1 single core cable of 1.5 Sqmm for earth wire), 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metal lic PVC concealed /surface conduit of 20 mm dia, medium grade with all conduit accessories / fittings, brass screws, washers etc and connected to common earth dully including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existingand taking down the old unserviceable submain wiring of ant type complete all as specified & directed.( Note - One meter of conduit along with 2x1.5 Sqmm wire and one 1.5 sqmm earth wire shall be measured as one length). |
| 246 | Material and labour for sub main wiring with 2x2.5 Sqmm nominal cross sectional area (two single core cable of 2.5 Sqmm for Phase and neutral + o1 single core cable of 2.5 Sqmm for earth wire), 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor cable with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metal lic PVC concealed /surface conduit of 20 mm dia, medium grade with all conduit accessories / fittings, brass screws, washers etc and connected to common earth dully including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existingand taking down the old unserviceable submain wiring of ant type complete all as specified & directed.( Note - One meter of conduit along with 2x2.5 Sqmm wire and one 2.5 sqmm earth wire shall be measured as one length). |
| 247 | supply and fixing twin core flexible copper wire 1 sqmm all as specified and directed. |
| 248 | Supply and fix0.75 sqmm 2 coreflexible copper cable multistrnded all as specified and directed. |
| 249 | supply and fixing flood light IP 66 100 watt all as specified and directed. |
| 250 | Supply and fixing ceiling fans complete with blades,copper winding, down rod accessories, 230 V, 1200 mm sweep. Min air delivery 225 CFM. Five star rated with brushless direct current motor (BLDC) , minimum 320 rpm all as specified and directed |
| 251 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450 mm sweep, 1400 RPM, 3250 CMHwith, blades, and frame and louvers al as specified and directed. |
| 252 | supply and fixing LED bulb 9 watt all as specified and directed. |
| 253 | supply and fixing LED bulb 9 watt (warm white) all as specified and directed. |
| 254 | supply and fixing LED bulb 15 wattall as specified and directed. |
| 255 | supply and fixingLED panel recessed type bulb 12 wattall as specified and directed. |
| 256 | Cleaning of rotational moulded polyethylene water storage tanks by removing of scale and dirt etc from tank and from mouths of circulating pipes etc of capacity exceeding 250 ltr but not exceeding 500 ltr complete all as specified.Note- Date of cleaning shall be mentioned on tank with synthetic enamel paint and cost of same is deemed to be included in the rates quoted by tenderer2. All tools and materials for cleaning the tank should be arranged by contractor. |
| 257 | Cleaning of rotational moulded polyethylene water storage tanks by removing of scale and dirt etc from tank and from mouths of circulating pipes etc of capacity exceeding 1000 ltr but not exceeding 2000 ltr complete all as specified. Note- Date of cleaning shall be mentioned on tank with synthetic enamel paint and cost of same is deemed to be included in the rates quoted by tenderer2. All tools and materials for cleaning the tank should be arranged by contractor. |
| 258 | Cleaning of water storage tanks of capacity 10000 ltrs by removing of scale, dumped sand, silt, debris and dirt any other foreign materials present in tanks/ walls and scrubbing out the floor etc. from mouths of circulating pipes etc and replacement of ball brass valve, high pressure, with polyethylene float and flynut complete, screwed for iron pipe or brass ferrule and fixed made of brass materials complete all as specified.Note-1.Date of cleaning shall be mentioned on tank with synthetic enamel paint and cost of same shall be deemed inclusive in quoted unit rate.2. All tools and materials for cleaning the tank should be arranged by contractor. |
| 259 | Cutting existing steel tubing 40 or 50 mm dia, screwing for alterations or additions for fittings such as unions, gate valves etc complete all as specified. |
| 260 | Cutting existing steel tubing 25 mm dia, screwing for alterations or additions for fittings such as unions, gate valves etc complete all as specified. |
| 261 | Taking up or down 50 mm dia bore GI tubing, and connections, including cleaning for re-fixing or removal to store complete all as specified. |
| 262 | Supply, fixing & laying of 50 mm dia bore GI tubing, medium grade with and including all fittings and fixture like socket, nipple, elbow, reducer etc complete laid in trenches or laid in floor complete all as specified. |
| 263 | S&F in replacement Gun metal gate valve with iron wheel head screwed both ends for GI steel tubing 50mm dia complete all as specified. |
| 264 | Taking up or down 25 mm dia bore GI tubing, and connections, including cleaning for re-fixing or removal to store complete all as specified. |
| 265 | Supply, fixing & laying of 25 mm dia bore GI tubing, medium grade with and including all fittings and fixture like socket, nipple, elbow, reducer etc complete laid in trenches or laid in floor complete all as specified. |
| 266 | S&F in replacement Gun metal gate valve with iron wheel head screwed both ends for GI steel tubing 25mm dia complete all as specified. |
| 267 | Taking up or down 20 mm dia bore GI tubing, and connections, including cleaning for re-fixing or removal to store complete all as specified. |
| 268 | Supply, fixing & laying of 20 mm dia bore GI tubing, medium grade with and including all fittings and fixture like socket, nipple, elbow, reducer etc complete laid in trenches or laid in floor complete all as specified. |
| 269 | S&F in replacement Gun metal gate valve with iron wheel head screwed both ends for GI steel tubing 20mm dia complete all as specified. |
| 270 | Supply, laying commissioning, testing of XLPE under ground LT cable 1100 volts grade of size 16 Sqmm 2 core armoured, PVC sheathed with aluminium conductor heavy duty laid in trenches, fixing on wall, under road crossing through protection pipe etc complete all as specified and directed. |
| 271 | Supply, laying commissioning, testing of XLPE under ground LT cable 1100 volts grade of size 16 Sqmm 4 core armoured, PVC sheathed with aluminium conductor heavy duty laid in trenches, fixing on wall, under road crossing through protection pipe etc complete all as specified and directed. |
| 272 | Material and labour for sand cushioningwith dry fine sand including filling, spreading, levelling in layers in cable trench with approved quality of sand for protection of under ground cable complete all as specified and directed. |
| 273 | Material and labour for contineous brick edging withwidth equal to the depth of the brick of whole sub class \"B\" bricks laid on edge complete all as specified and directed. |
| 274 | Supply / laying and fixing 40 mm bore galvanised steel tubes with all fittings, light grade, laid in trenches for cable protection complete all as specified and directed. |
| 275 | Note : Tenderers may note that amount of credit Rs 1,12,031.80 will be deducted from the total amount arrived, at the time of Acceptance of contract. |