| 1 | Civil Work |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. (No extra lift is payable if work is done by mechanical means) All kinds of soil |
| 3 | Excavating trenches of required width for pipes, cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m including getting out theexcavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : (No extra lift is payable if work is done by mechanical means) in all kinds of soil: Pipes, cables etc., not exceeding 80 mm dia. |
| 4 | Excavating trenches of required width for pipes, cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m including getting out theexcavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : (No extra lift is payable if work is done by mechanical means) in all kinds of soil : Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for concrete upto plinth level |
| 6 | Centering and shuttering in cluding strutting, propping etc. and removal of form for: Columns, Pillars , Piers, Abutments, Posts and Struts. |
| 7 | Centering and shuttering in cluding strutting, propping etc. and removal of form for: Walls (any thickness) in cluding attached pilasters butter esses, plinth beams and string courses etc. Uptoplinthlevel. |
| 8 | Centering and shuttering in cluding strutting, propping etc. and removal of form for: Lintels, beams, girders, bressumers and cantilevers |
| 9 | Centering and shuttering in cluding strutting, propping etc. and removal of form for: Weather shade, Chajjas, corbels etc., including Edges. |
| 10 | Centering and shuttering in cluding strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform. |
| 11 | Centering and shuttering in cluding strutting, propping etc. and removal of form for: Small lintels not exceeding 1.5m clear span, mouldingas incornices, window, sills, courses, bands, copings, bed plates, anchor blocks and the like. |
| 12 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : With 20mm nominal size graded stone aggregate. M-10 Nominal (Mix-1 Cement : 3 sand : 6 graded stone aggregate ) |
| 13 | Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone aggregate) excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : M-20 Grade Concrete |
| 14 | Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, posts and struts etc. above plinth level and upto floor two level excluding cost of centering, shuttering, finishing and reinforcement: M-20 Grade Concrete |
| 15 | Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate)in beams, suspended floors, roofs havingslope of any degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiralstaircases above plinth level and upto floor two level excluding the cost of centering, shuttering, finishing and reinforcement in concrete grade. M-20 Grade Concrete |
| 16 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. upto floor two level, excluding the cost of centering, shuttering and finishing : With 20mm nominal size graded stone aggregate M 20 – Grade concrete |
| 17 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detaling IS-456 RCC Design & SP 34 Reinforcement detailing ) etc. complete .(Note:-1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge.2. No extra payment shall be done for overlaps and/or couplers.3. Couplers shall be conforming to IS code on “Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification”) Thermo-Mechanically Treated bars. FE 500conforming to IS 1786 |
| 18 | Filling available excavated earth (excluding hard rock/Ordinary rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 19 | Supplying and filling in plinth under floors including watering ramming consolidating in layers not exceeding 20cm in depth and dressing complete Supplying and filing in plinth with soil (other then BC soil ) having MDD not less than 1.85 t/m3 under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 15cm depth and dressing complete. |
| 20 | Supplying chemical emulsion in sealed containers including delivery as specified. (Chlorpyriphos/ Lindane emulsifiable concentrate of 20%) |
| 21 | Making plinth protection 50mm thick of cement concrete grade M10 over 75mm bed of dry metal ballast 40mm nominal size well rammed and consolidated and filled with sand including finishing the top smooth (with 20mm nominalsize graded stone aggregate.) |
| 22 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3mm dia. round headed screws, one lock at the corners. Clamp shall be made of 16mm dia M.S. bar bent to shape as per standard drawing. |
| 23 | Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, up to plinth : Having 50 kg / cm2 average compressive strength. Cement mortar 1:6 (1 cement : 6 sand) |
| 24 | Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, in super structure above plinth level up to floor two level in : Having 50 kg / cm2 average compressive strength. Cement mortar 1:6 (1 cement : 6 sand) |
| 25 | Half brick masonry with fly ash lime Gypsum bricks (FALG bricks) conforming to IS: 12894, in super structure above plinth and upto floor two level.: Having 50 kg / cm2 average compressive strength. Cement mortar 1:4 (1 cement : 4 sand) |
| 26 | Supplying and applying fibre reinforced, UV resistant elastomeric liquid applied waterproofing & Heat reflective coating coating with PU Hybrid polymers & acrylic fibers. The coating shall resist 10 bars of water pressure as per DIN 1048 standards, with elongation of 350% as per ASTM D412 &crack bridging of upto 2.5mm conforming to ASNZ standard. The operation shall be carried out after scrapping and properlycleaning the surface to remove loose particles with wire brushes, complete in all respect as recommended by the manufacturer’s specification and as per the direction of Engineer-in-Charge |
| 27 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete with base of cement mortar 1 : 4 (1 cement : 4 sand) having thickness of slab 25 mm (Area of slab to be over 0.25 sqm) Note: - Deduction shall be made for not mirror polishing according to item no 11.43 |
| 28 | Kota stone slabs in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete 20 mm thick |
| 29 | Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. |
| 30 | Providing and fixing Ceramic glazed wall tiles 300x450 mm or more (having thickness 6 to 7 mm) of 1st quality conforming to IS: 15622 of approved make in all Colours& shades, except burgundy, bottle green, black laid on 12mm thick bed of Cement Mortar 1:3 (1 Cement: 3 sand)preprad same day when mortar is still green jointed with grey cement slurry @3.3 kg per sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 31 | Providing and laying Ceramic glazed floor tiles 300x300 mm or more (having thickness 6 to 7mm) of 1st quality conforming to IS : 15622 of approved make in any colours and shade laid on20 mm thick Cement Mortar 1:4 (1 Cement : 4 sand) including pointing the joints with white cement and matching pigment etc., complete. |
| 32 | Providing and fixing pressed steel door frames made of 1.6 mm thick steel profile conforming to IS: 4351 manufactured from commercial mild steel sheet including hinges, jamb, lock jamb, bead and if required angle threshold of mildsteel angle of section 50x25mm, or base ties of 1.60 mm pressed mild steel welded or rigidly fixed together by mechanical means, including 2.5mm thick M.S. pressed butt hinges, with mortar guards, lock strike- plate and shock absorbers as specified filling the frame with Cement Concrete 1:3:6 at site before fixing (costof concrete to be paid separately) fixing with adjustable lugs (200 mm long & 1.0 mm thick) and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in- charge: Profile B of 1.60mm thick single rebate of size 80mmx50mm Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). |
| 33 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I)non- decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 34 | Providing and fixing factory made UPVC door frame made of UPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2mm), corners ofthe door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frame reinforced by galvanized M.S. tube of size 19 X 19mm and 1mm (± 0.1 mm) wallthickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-charge:Extruded section Profile size 48x40 mm. |
| 35 | Providing and fixing Panelled UPVC doorshutter to existing door frames. 24 mm thick factory made UPVC door shutters made of styles and rails of a UPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shuttereinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of a UPVC hollow \"H\" section, section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. \"U\" cleats. The shutter frame filled with a UPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer\"s specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter). |
| 36 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete: 250x16 mm |
| 37 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 250x10 mm |
| 38 | Providing and fixing aluminium towerbolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:150x10 mm |
| 39 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125 mm |
| 40 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 100 mm |
| 41 | Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. Twin rubber stopper |
| 42 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. |
| 43 | Providing and fixing factory made ISI marked glazed steel doors, windows and ventilators side /top /centre hung with beading and Z-section all members such as F7D, F4B, K11 B and K12 B and other tubular section member etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of Cement Concrete 1:3:6 (1 Cement : 3 sand : 6 graded stone aggregate 20 mm nominal size) |
| 44 | Providing and fixing glass panes/ steel sheet/ fibre sheet with putty and glazing clips in steel doors, windows, clerestory windows all complete. With 4.0 mm thick glass panes |
| 45 | Providing and fixing on wall face Rigid Unplasticised rigid PVC (upvc) Single socketed rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion 110 mm diameter (minimum wall thickness 2.2mm) |
| 46 | Providing and laying below ground unplasticised PVC pipe to with stand working pressure of 4 kg/cm2 soild waste pipes confirming to IS:13592 andIS:4985 including jointing with seal ring confirming to IS :5282 leaving 10mm gap for thermal expansion all necessary fittings etc. complete. Excavation to be paid seperataly110 mm diameter OD (min. wall thickness 3.2mm) |
| 47 | Providing and laying cement concrete 1:3:6 (1 cement: 3sand: 6 graded stone aggregate 20 mmnominal size) all-round PVC. pipes including bed concrete as per standard design: 110 mm diameter PVC. Pipe |
| 48 | Providing and fixing on wall face Unplasticised - UPVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single tee without door 110x110x110 mm (minimum wall thickness 2.2mm) |
| 49 | Providing and fixing on wall face Unplasticised - UPVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Shoe (Plain) 110 mm Shoe (minimum wall thickness 2.2mm) |
| 50 | Providing and fixing on wall face Unplasticised - UPVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend (minimum wall thickness 2.2mm) |
| 51 | Providing and fixing to the inlet mouth of rain water pipe fixing cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 52 | UPVC trap of self cleaning design Providing and fixing UPVC trap ofself cleaning design complete. Including cost of cutting and making good the wall and floors. 100 mm inlet and 75 mm outlet |
| 53 | Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc.complete. 110 mm (minimum wall thickness 2.2mm) |
| 54 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast Iron P or Strap, UPVC P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures completeincluding cutting and making good thewalls and floors wherever required :White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests. |
| 55 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap. |
| 56 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe (only in residential & complaxes) 32 mm dia |
| 57 | Providing and fixing PTMT grating of approved quality and colour. Circular type. 125 mm nominal dia with 25 mm waste hole. |
| 58 | Providing and fixing C.P. brass grating of approved quality and make conforming to IS: specification. 100 mm dia |
| 59 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour. 600mm long towel rail with totallength of 645mm, width 78mm and effective height of 88mm, weighingnot less than 190gms. |
| 60 | Providing and fixing bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 61 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Concealed pipe including painting with anti corrosivebitumastic paint, cutting chases and making good the wall. 15 mm dia nominal bore |
| 62 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.: Internal work - Internal work - Exposed on wall 20 mm dia. nominal bore |
| 63 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. External work : including trenching and refilling etc. -25 mm dia. nominal bore |
| 64 | Deduct for not providing hinges in doors, windows or clerestory window shutters with : Stainless steel butt hinges with stainless steel screws for 2nd class teak wood and other class of wood shutters. |
| 65 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore |
| 66 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore. |
| 67 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS: 8931and weighing not less than 400gm, 15 mm nominal bore. |
| 68 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 20mm nominal bore |
| 69 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 25mm nominal bore |
| 70 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore |
| 71 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 sand) |
| 72 | 12 mm cement plaster of mix :1:4 (1 cement : 4 sand) |
| 73 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement : 4 sand) |
| 74 | Wall painting by any mechanical or manual means with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work |
| 75 | Wall painting by any mechanical or manual means with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand andmanufacture, including applying additional coats wherever required, toachieve even shade and colour. Two coats |
| 76 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. |
| 77 | Providing and fixing squaremouth S.W. gully trap class SP1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design : 100x100 mm size P type With well burnt bricks each 1764.00 |
| 78 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 sand ) R.C.C. top slab with Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stoneaggregate 20mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard designInside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be notless than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With well burnt bricks. |
| 79 | Making connection of drain or sewer line with existing manhole including breakinginto and making good the walls,floors with cement concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cementmortar 1:3 (1 cement : 3 sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 230 mm diameter |
| 80 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank |
| 81 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. Rate includes recess cutting in floor and making good the same wherever required. |
| 82 | Electrical Work |
| 83 | Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLSH with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLSH copper earth continuity conductor of green colour inside conduit, screwless connector for joints etc. as required as per specification for :- Light point/fan points. Primary short point Using modular accessories |
| 84 | Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLSH with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLSH copper earth continuity conductor of green colour inside conduit, screwless connector for joints etc. as required as per specification for :- Light point/fan points. Primary medium point Using modular accessories |
| 85 | Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLSH with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLSH copper earth continuity conductor of green colour inside conduit, screwless connector for joints etc. as required as per specification for :- Light point/fan points. Primary long point Using modular accessories |
| 86 | Point wiring (excluding metallic switch box &sheet but including switches, sockets) for 3 pin 6 Amp. socket outlet point with 1.5sq. mm. PVC insulated cable FRLSH with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit with required materials as per specification on same board. |
| 87 | Supplying and fixing of approved make modular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for: 12 Module metal box |
| 88 | Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLSH with copper multi strand conductor ISI marked in surface rigid steel conduit ISI marked of suitable size including painting etc. with 20/16 Amp. F.T. switch &socket/S.S. combined 20/16/6 amp. of ISI marked and 4sq. mm. PVC insulated FRLSH copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :- Using modular accessories Power point On separate board Short point |
| 89 | Supplying and fixing of approved make modular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for: 1 or 2 Module metal box |
| 90 | Wiring for sub-mains with PVC insulated cable FRLSH with copper multi strand conductor ISI marked in recessed/concealed rigid PVC conduit (HMS) ISI marked of suitable size (conduit included) including 2mm thick accessories, connection etc, as required as per specification. (Refer General Notes for Classification of Conduit Wiring Point No.10) 3 Wire sub main 2.5 sq. mm. cable |
| 91 | Wiring for sub-mains with PVC insulated cable FRLS with copper multi strand conductor ISI marked in recessed/concealed rigid PVC conduit (HMS) ISI marked of suitable size (conduit included) including 2mm thick accessories, connection etc, as required as per specification. (Refer General Notes for Classification of Conduit Wiring Point No.10) 3 Wire sub main 4 sq. mm. cable |
| 92 | Supply and fixing of approved make step type modular electronic fan regulator including connection etc. as required on existing board : 100 Watt (1 module). |
| 93 | Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of \"C\" series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :- Single Pole MCB SP 6Amp to 32Amp 10kA rating |
| 94 | Supplying and installing of RCBOs (Residual current circuit breaker with overload and short circuit protection) ISI marked complete as per I.S. standard conforming to IEC:61009-1 & IS:12640-2, 240/415V 50 Hz with 10 kA short circuit withstand capacity for earth leakage, overload & short circuit protection including connection in existing enclosure in approved manner as per specification DP (4 module) 2 pole 32Amp, 30mA sensitivity |
| 95 | Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor 3½ core unarmoured 25 sq. mm |
| 96 | Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator) 16 Way double door IP 43 protection |