| 1 | Servicing of diesel driven fire pump set centrifugal type of head 55 mtr, discharge 100 cubic mtr per hour model DB 100/32, cleaning of pump outer filling of grease in pump, changing of gland packing, bushes and gasket and replecement of mechanical seal complete all as specified and directed.Make: Kirloskar Brothers Ltd. |
| 2 | Servicing of diesel driven fire pump set centrifugal type of head 58 mtr, discharge 97 cubic mtr per hour model DB 65/20, cleaning of pump outer filling of grease in pump, changing of gland packing, bushes and gasket complete all as specified and directed. |
| 3 | Servicing of diesel driven fire pump set centrifugal type of head 56 mtr, discharge 11 cubic mtr per hour model DB 32/20, cleaning of pump outer filling of grease in pump, changing of gland packing, bushes and gasket complete all as specified and directed. |
| 4 | Supply only of Mechanical seal for DB 100/32 fire pump set centrifugal type complete all as specified and directed. |
| 5 | Supply only of Mechanical seal for DB 32/20 fire pump set centrifugal type complete all as specified and directed. |
| 6 | Supply only of Mechanical seal for DB 65/20 fire pump set centrifugal type complete all as specified and directed. |
| 7 | Supply and fix in repair butterfly valve of PN 1.6 rating and replace with neoprene rubber sealing seat and stainless steel stem level/gear operation and cast iron body in powder coated finish for fire fighting application of size 100 mm dia in existing line complete all as specified and directed. Make: Zoloto/Kartar/Lakshmi/Venus/RMCO or ISI Marked |
| 8 | Supply and fix in repair butterfly valve of PN 1.6 rating and replace with neoprene rubber sealing seat and stainless steel stem level/gear operation and cast iron body in powder coated finish for fire fighting application of size 150 mm dia in existing line complete all as specified and directed. Make: Zoloto/Kartar/Lakshmi/Venus/RMCO or ISI Marked |
| 9 | Supply and fix in repair 100 mm dia pipe foot valve as perIS-4038 of cast iron with brass diaphragm heavy duty flangetype complete all as specified and directed. Make: Zoloto/Kartar/Lakshmi/Venus/RMCO or ISI Marked |
| 10 | Supply & Fixing in repair/replacement /maint of rubber hose reel pipe 25 mm dia 30 mtr long incl Nozzle with drum and all accessories etc complete all as specified and as directed. Make: MINIMAX/FIREX/SAFEX/ NEW AGE or ISI Marked |
| 11 | Supply and fix in repair Gun metal ball valve ISI markedhigh pressure with iron wheel headscrewed both ends for iron pipe line and fixedproperlyof 25 mm dia sizes. Make - Zoloto/Kartar/Lakshmi/Venus/RMCO or ISI Marked |
| 12 | Supply & Fixing of brass nozzels with ball valve of dia 15 mm at end ofexisting hose reel pipeas per existing sample complete all as per specified and directed. Make - Zoloto/Kartar/Lakshmi/Venus/RMCO or ISI Marked |
| 13 | S&F in repairs fire fighting canvas hose pipe, fire chief brand, cotton synthetic fibre, circular woven jacketed rubberized fabric reinforced rubber lined (RRL) , 35.7 Kg/cm2 burst pressure and 22 Kg/cm2 proof pressure, 63 mm dia of 15 mtr long with male and female GM coupling of 63 mm diaall as specified .(Make – Zenith/ Jyoti/Fire Shield or ISI Marked). |
| 14 | S&F in repairs fire fighting Branch pipe gun metal 63mm instantaneous inlet, made threaded outlet, 15mm bore nozzle short all as specified .(Make – Zenith/ Jyoti/Fire Shield or ISI Marked) |
| 15 | S&Fin repairs fire fighting GM landing valve (Hydrant valve single headed)with 80 mm NB flanged inlet brass spindle 63 mm dia female oblique outlet bearingall as specified and directed by Engineer – in – Charge.(Make – Zenith/ Jyoti/ Fire Shield or ISI Marked) |
| 16 | Supply and fabrication of fire hydrant hose box of size 800mmx 600mmx 250mm with 3 mm thick double door with 4 mm thick glasses and door frame made of 16 gaugeMS sheet and 40mmx 40mm x 6mm thick iron angle support at 1.5 mtr height including grouting, painted FIRE with red outside and brilliant white inside box including taking down old unserviceable all as specified. Make: (Make – Zenith/ Jyoti/Fire Shield or ISI Marked) |
| 17 | Supply and fixing in repairs fire brigade inlet connection 4 way valve ISI marked including taking down unserviceable old one complete allas specified and as directe. Make : NEWAGE/ ESSEL /SRI/EVER SAFE/AADI/CRC or ISI Marked |
| 18 | Cleaning of fire static tank of capacity 20000 Gallons for fire fighting system by draining out the water and taking out the sludges from the bottom of the static water tank and cleaning mossy on walls of the tank and scraping by wire brush & brooms applying two coats of weather coaton outer surface complete all as specified and directed.Note: Weather coat paint and if plater required on outer side measured and paid saperately. |
| 19 | Supply, install, testing and commissioning of Pressure release valve complete all as specified and directed. |
| 20 | Material and labour for repair of bottom sheet of Diesel fuel tank of 200 litres capacity fabricated out of 3 mm thick MS sheet in cubical shape complete with all standard accessories and flexible fuel piping between fuel tank and diesel engine including painting complete all as required and directed. |
| 21 | Servicing of fire pump engine rating 28/38 KW/HP ,Make : Kirloskar, with replacement of Engine oil, Oil filter, Diesel filter , Air Clearner Element, Cleaning of battery terminal , checking of tappet clearance & related accessories such asset of \"O\" ring, set of tappet gasket, Set of washers,Dusting ,Cleaning and testing of Engine Set all as directed by Engineer-in-Charge. Note : Engine oil, oil filter, Diesel filter , Air Clearner Element etc will be meseared and paid under relevent item.Note : Servicing of engine to be done by Authorised service provider of engine Make. |
| 22 | Supply only for above item No 21 Fuel filter element pre |
| 23 | Supply only for above item No 21 Fuel filter element micro |
| 24 | Supply only for above item No 21 Lubricating oil filter |
| 25 | Supply only for above item no 21 Main element for air cleaner |
| 26 | Supply only for above item no 21 Engine Oil |
| 27 | Supply only for above item no 21 coolent |
| 28 | M & L for repair ofself starter 12 Voltsby replacing unserviceable Groove wheel/armature, carbon brus including testing and commissioning complete all as specified and directed |
| 29 | Testing and repairing of Fire Hydrant water line to arrest leakage to stand specified line pressure and restoration of pressure cut out switch for auto start and stop of fire pumps ati.e, Jockey fire pump, Main Pump and Diesel driven pump at set water line pressure including testing complete all as specified and directed.Note: Man power required for excavation and return filling, welder for arresting leakage with welding machine and welding rod all are included in quoted rate. |
| 30 | S&F in replacement of selector switch as per exising complete all as specified |
| 31 | S&F in replacement volt meter, 3 phase volt of size 96 X 96 MM as per exising complete all as specified |
| 32 | S&F in replacementAmmeter , 3 Phase ofSize 96X96 MM as per exising complete all as specified |
| 33 | S&F in replacement power contactor of capacity 32 Amps, AC3 ML3, 415 volts main contactor coil voltage 110 Volt type as per exising complete all as specified |
| 34 | Taking down cement plaster of any description from brick/ stone walls surfaces including. racking out joints, hacking for key, scrubbing down with water etc. and removing debris to a distance n.exc. 50 m, complete all as specified anddirected. |
| 35 | M&L for rendering 15mm thick cement plaster on in two layers each of 10+5mm thick in Cement Mortar (1:3) with WPC @3% wt of cement on fair faces of brick work completeallas specified and directed.(Note :Integral water proofing compound shall be measured and paid separately under respective item of Sch ‘A’) |
| 36 | Demolition of concrete (Un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 37 | M & L PCC (1:2:4) type B1 (12.5 mm graded aggregate)as in roof kerbs, slightly rounded or chamfered on edges, Bases of static water tanks, mixed with water proofing compound in top layer @ 3% by weight of cement or as per manufacturer instructions finished even and smooth on exposed concrete surface without using extra cement all complete as specified and as directed. (Note: Water proofing compound shall be measured and paid perarately under relevant item of schedule \"A\"). |
| 38 | Supply only integral water proofing compound confirming to IS 2645 – 2003. MAKE : SIKA/ ACCOPROOF/ CICCO NO-1 |
| 39 | Material & Labour for applying waterproof chemical to sprade on floor and wall of SWT to make water leakage proof complete all as specified and directed. Make: Fosroc / M seal / Sika |
| 40 | Material & Labour for applying Two or more weather coats on outer surface ofSWT 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |