| 1 | Demolition of un-reinforced cement concrete in ground floors and pavings n.exc 15cm thickness, (Below or above Ground level) and disposal ofdebris and rubbish complete all as directed by the Engr-in-Charge |
| 2 | Demolition of brick work or stone / boulder masonry/ concrete block masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal ofdebris and rubbish complete all as directed by the Engr-in-Charge. |
| 3 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and disposal ofdebris and rubbish complete all as specified and directed. |
| 4 | M & L for 25 mm thick, plain cement concrete 1:2:4,type B-0 (using 12.5 mm graded stone aggregate)as in sub-base of flooring, etc and finished the surface even and rough complete all as specified and directed. |
| 5 | M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm, in floors etc, and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6complete all as specified and directed. |
| 6 | Demolition ofStone slabs and tiles of any description or thickness in floors, aprons etc.laid bedded and pointed in any mortar and removing rubbish complete all as directed by the Engr-in-Charge. |
| 7 | M & L for 18-20 mm thick Machine cut kota stone slab flooringlaid overand including20 mm thick screed bed in cement mortar (1:6). and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing and moulding completeall as specified and directed by the Engineer-in-Charge. |
| 8 | M & L for 75 mm thick,plain cement concrete1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed. |
| 9 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 10 | S & F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe-410-W (Gde-E-250) quality-B complete all as specified and directed. |
| 11 | M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and directed. |
| 12 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, in roof covering including ridges and keeping serviceable sheets in safe custody for reuse in the work complete as directed. |
| 13 | S & F Pre-Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer\"s instruction complete all as specified and directed. |
| 14 | S & F Pre-Painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/vally gutter, fixed with self tapping screws as per manufacturer\"s instruction complete all as specified and directed. |
| 15 | S & F 0.63mm thick galvanised, corrugated mild steel sheeting in roof coveringhaving zinc coating @ 150 gms/Sqm with two corrugation side lap, fixed with L type or J type or cranked hook bolts complete all as specified and directed. |
| 16 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness including cover fillets/snap grid/frame work etc complete all as specified and directed. |
| 17 | S & F aluminium Anodised snap grid frame work of size 605mm x 605mm frame work for ceiling with aluminium tee section of size 23.5mm x 26.4mm x 1.4mm thick and aluminium angle section of size 36.5mm x 25mm x 1.4mm thick, for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long including 4 mm thick non asbestor E-board, HSPC, designer fixed to framecomplete all as specified and directed by the Engr-in-Charge. |
| 18 | M & L for Pre-cast cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate),block masonry with solid blocks of size 300x200x200mm or 300x200x100mm, having compressive strength of not less than 100 Kg/Sq Cm (As per IS-2185) exc. 10 cm in width and setting in mortar 1:6 complete all as specified and directed. |
| 19 | Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water and removing rubbish complete all as specified and directed |
| 20 | M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 21 | M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4,mixed with integral water proofing compoundwith weight of cement in top layer as per manufacturer\"s instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item). |
| 22 | Supply only integral water proofing compound (ISI marked) complete all as specified and directed. |
| 23 | M & L for preparing newly plastered surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and directed. |
| 24 | M & L for Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed. |
| 25 | Taking down chowkats or frame, n.exc 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and directed. |
| 26 | Taking down chowkats or frames, exc 1.5 but n.exc. 4 Sqm in each with shutter (without taking off shutter from the frame)complete all as specified and directed. |
| 27 | Taking down shutters of any description exc 1 Sqm but n. exc 2 Sqm each complete all as specified and directed. |
| 28 | S & F Rolled sections as in framing for cladding, glazing, chowkat and the like fixed with angle cleats and connecting plates, etc Conforming to Fe-290 (Gde E165) complete all as speicfied and directed. |
| 29 | M & L for plain cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) for embedding holdfast, bed block, cills, etcincluding necessary form work complete all as specified and directed. |
| 30 | S & F 35 mm thick, factory made Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 31 | S & F 35 mm thick, glazed/skeleton shutters with second class hard wood,open rebated and prepared to receive glass, gauze, etc (without sash bars)edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass, etc complete as specified and directed . Sizes of members of shutters as specified in SSR Part I, Section -8, clause 8.24 (a). |
| 32 | S & F Powder coated aluminium sections (minimum 50 micron) of approved colour as in door, window, ventilator frames, partitions with one or more rebates and door, windows shutters sliding/openable type/ventilator shutter including provision of necessary jointing cleats, glazing clips, neoprene rubber packing, powder coated aluminium snap beading, screws inclding provision of suitable size of powder coated aluminium fittings such as locking arangements, handles, stainless steel fiction hinges and tower bolts etc including fixing only glass panels/particle board panels/wire gauge/aluminium grill etc complete all as specified and directed. (Note : (i)The size of aluminium sections shall be all as specified in relevant IS Code and MES Schedule Part-I (ii) S & F of Glass panels/ Partricle Board panels/ Wire gauge shall be measured paid seperately as supply only rates under respective items here-in-below). |
| 33 | Supply only 4 mm thick, sheet glass, ordinary quality and glazing with wooden beading/rubber beading not exceeding 0.5 Sqm in each pane complete all as specified and as directed. (Note: The cost of rubber beads and fixing included with the unit quoted rate of respective shutter) |
| 34 | Supply onlyStainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplescomplete all as specified and directed.(Note: The cost of fixing included with the unti quoted rate of respective shutter) |
| 35 | S & FStainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplescomplete all as specified and directed. |
| 36 | S & F in repairStainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplescomplete all as specified and directed. |
| 37 | S & F 100 mm long, stainless steel butt hinges fixed with stainless steel hinge pin etc complete all as specified and directed. |
| 38 | S & F 200 mm long, Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 39 | S & F 150 mm size, extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 40 | S & F Aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clipes of sheet, cast or extruded sections and fixing bolts of extruded sectionsor cast aluminium alloy, length of bolt of 300 mm complete all as specified and directed. |
| 41 | S & FFloor door stopper of aluminium alloy body and tongue, anodised, 140 mm overall length of cover plate with hard drawn steel spring, fixed in floorcomplete all as specified and directed. |
| 42 | S & F 300 mm long,mild steel, ordinary rat tail rod pattern springs incuding roller and roller plate complete all as specifed and directed. |
| 43 | M & L for Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed. |
| 44 | S & F in repairs 24 mm outer dia, stainless steel, curtain rail/rod, heavy duty, minimum 1mm wall thick including brackets, side holder and rings etc fixed to /wall etc complete all as specified and directed.(Note: (i) Stainless steel decorative finials and stainless steel brackets shall be provided for each leangth of curtain rail/rod and cost of the same shall deemed to be included in the unit quoated rate. (ii) Length of of curtain rail/rod shall only be measured for payments) |
| 45 | M & L for Preparation of oldpainted steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint complete all as specified and directed. |
| 46 | M & L for Preparation of old treated asbestos cement surfaces of ceiling etc of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paintcomplete all as specified and directed. |
| 47 | S & F in repairs, 15 mm bore, Stop/angle valves,cast copper alloy,chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 48 | S & F1000 litres capacityrotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top), hoisted and fixed in position including taking down old unserviceable one as specified in SSR Part I and directed. |
| 49 | S & F in repairs, 20 mm bore,Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) complete all as specified and directed. |
| 50 | S & F in repairs, 20 mm bore, gun metal Gate valves, with iron wheel head, Class-I, Pressure Tested of 1.5 Mpa, screwed both ends for iron pipe complete all as specified and directed. |
| 51 | S & F in repairs, 15mm bore, bib taps, fancy type, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 52 | S & F in repairs, stainless steel kitchen sinks with drainage board made of1 mm thick sheet for kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm and bowl size 410mm x 330mm x 160mm complete all as specifiedand directed. |
| 53 | Taking up or down 15/20mm bore/dia, Steel tubing/ PP-R pipe and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed. |
| 54 | Taking up or down 20/25mm bore/dia, Steel tubing/ PP-R pipe and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed. |
| 55 | Supply, laying, connection and testing, 20mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed |
| 56 | Supply, laying, connection and testing, 25mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed |
| 57 | Taking up or down eaves gutters and rainwater/soil/waste pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including removal to Store (measured overall as fixed along the centre line over fittings and accessories)complete all as specified and directed |
| 58 | S & F 75 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, etc completeall as specified and directed. |
| 59 | S & F75 mm bore, PVC (SWR) bends of any radius complete all as specified and directed. |
| 60 | S & F 75mm bore, PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 61 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 62 | Taking down unserviceable main switches, DBs, bus bars chambers, VTPN etc any capacity including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified anddirected. |
| 63 | M & L for Point wiring for one light/exhaust fan/fan point/call bellcontrolled by one way switch with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC casing capping (ISI marked) (aprox size 20/25/40mm width) surface type with all fittings/fixtures such as Tee, Bend, elbow, socketr, shaddle etc including 1.5mm thick MS sunken/terminal box including 3mm thick backelite sheet cover for fixing flush type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductorcable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed.(Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.) |
| 64 | All as per item No. 63 above but for One 3/5 pin socket outlet 6 amps pointon same boardcomplete ditto |
| 65 | All as per item No. 63 above but forOne 3/5 pin socket outlet 6 amps on independent board complete ditto |
| 66 | All as per item No. 63 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistrandedFRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cableFRLS (ISI marked) as earth lead complete ditto |
| 67 | S & F switch piano Flush type, single pole one way 6 Amp 240 volts, complete all as specified and as directed. |
| 68 | S & F Socket outlet 2 in 1, 3 pin, 6 Amps, flush type complete all as specified and as directed. |
| 69 | S & F Switch socket combination 2 in1, 3 pin, 6 Amp, flush type, universal complete all as specified and as directed. |
| 70 | S & F Switch socket combination 2 in1, 3 pin, 6 and 16Amp, flush type, universal complete all as specified and as directed. |
| 71 | S & F ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed. |
| 72 | S & F Stepped type electonic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and as directed. |
| 73 | S & F LED tube light fittings, retro bar professional WH 5700K to 6000K, 20 Watt and 2000 Lumens of cool white with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specifiedand directed. (Make: Havell\"s Cat No. LUMILINEPLUSBS20WLED865SPCSS or equivelant of make as per list of manufacturer) |
| 74 | S & F 2ftx2ft recessed mounting, LED panel light fittings, 36 Watt with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specifiedand directed. (Make: Havell\"s Cat No. VENUSNEOHE2X2R36WLED840PIRSENSOR or equivelant of make as per list of manufacturer) |
| 75 | S & F LED Bulk Head, 10 Watt, IP 65 rated, compact design, PC Co extruded with high energy saving with all accessories and connecting up including lamp complete all as specifiedand directed. (Make: Crompton Cat No. TIS-304-10-57-SL-DP-NWH or equivelant of make as per list of manufacturer) |
| 76 | S & F Lamp Holder, PVC/ Polycarbonate type with backplate suitable for batten fitting complete all as specified and as directed. |
| 77 | S & F LED Bulb, 15 Watts, B-22 Lumen ≥ 900, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra,IP 20 rated, overmoulded plastic housing, polycarbonate diffuser, 4KV surge Protection with over voltage protection withstand upto 440 V (for 10 Minute) with open and short circuit protections as per IS: 16102 complete all as specifiedand directed. |
| 78 | Taking down and dismantling the ceiling fan 1200 / 1400 mm sweep of any capacity from existing position and transportation to workshop for rewinding etc and back, removing its allied spare parts for cleaning, servicing, oiling and lubricating and replacement of unserviceable minor parts and refixing the same fan in its original position with all the parts i.e. down rod, canopies, fan blades, spilt pins, screws, nuts and spring washers etc and applying one coat of spray painting complete including provn flexible copper conductor cable of 24 / 0.20mm of required length with necessary connector (for blade / body) as required complete all as specified and directed. (Note : (i) Cost of minor spare parts shall deemed to be included in quoted rate. (ii) The cleaning, servicing, oiling and lubricating of fans has to be carried at site itself and to be completed withing one hour unless re-winding is required. (iii) The cost of transportation from site of work to workshop and back for rewinding is deemed to be included in the unit quoted rate, (iv) Rewinding shall be carried out in contractor\"s workshop and fan shall be re-fixed at site withing 10 days after taking down from site. Any delay after 10 days shall be panalised @ Rs. 100.00 per day for a maximum of 10 days). |
| 79 | M & L for rewinding of Ceiling fan of any sweep after dismantling with super enamelled bareinsulated copper winding wires as per existing gauge and turn to achieve desiredRPM including necessary insulating materials, insulating varnishing, cleaning, packing and reassemblingand testing etc complete all as specified and as directed. ( Note: Also refer Note No. (iv) under Serial item No. 78 above) |
| 80 | S & F Distribution Board, SPN 8 Way, 240V, Double door with IP 43 protection IK 09 complete all as specified and as directed. (Make: Havell\"s cat part No. DHDPSHODRW08 or equivalent make as per List of Manufacturer\"s) |
| 81 | S & F MCB SPN 6-32A Amps, 240 Volts,10KA, C Curve complete all as specified and as directed (Make: Havell\"s cat part No. DHMGCSNF006-032 or equivalent make as per List of Manufacturer\"s) |
| 82 | S & F MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve,complete all as specified and as directed (Make: Havell\"s cat part No. DHMGCSPF006-032 or equivalent make as per List of Manufacturer\"s) |
| 83 | M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar),including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed,including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessarytesting on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge. |
| 84 | S & F in repairs PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 175 mm x 100 mm and 50 mm deep complete all as specified and directed. |
| 85 | S & F in repairs PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 200 mm x 150 mm and 50 mm deep complete all as specified and directed. |
| 86 | S & F 1100 volts grade, heavy duty cablePVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathedin service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, 16 Sqmm 2 core solid conductor including taking down existing one complete all as specified and directed. |
| 87 | S & F in repair House service bracket (hook type) complete with 3.0m long GI pipe 40mm dia, Medium Grade, two nos. 90 degree bends, M.S. hook and stay or guy complete all as specified and directed. |