}

Tender For Special Repair To Building No T 36 Otm Accommodation And E 06 Otm Accommodation Of Demo Tps, At Hq Jl Wing The Inf School Under Ge Belgaum., belgaum-Karnataka

Tender Notice

51915212
Tender For Special Repair To Building No T 36 Otm Accommodation And E 06 Otm Accommodation Of Demo Tps, At Hq Jl Wing The Inf School Under Ge Belgaum.
Tender
Indian
Karnataka
Belgaum
15-11-2025

Tender Details

Tender For Special Repair To Building No T 36 Otm Accommodation And E 06 Otm Accommodation Of Demo Tps, At Hq Jl Wing The Inf School Under Ge Belgaum.; 1 S&F 2nd class HW scantlings, clean sawn supplied and fixed, with and including dismantling existing u/s timber scantling framed work 40sq.cm and over section, in any position, complete all as specified and as directed. 2 Taking down & refixing in old or new position of 2nd class HW scantlings, clean sawn, with and including dismantling existing u/s timber scantling framed work 40sq.cm and over section, in any position, complete all as specified and as directed. 3 M&L for Preparing surface of wood and wood based materials, new or old, of any description and girthand treated with two coats of creosote oil, complete all as specified and as directed. 4 M&Lfor Cement concrete roofing tiles, rustic red colour, 420mm x 330mm size of 230 kg minimum breaking strength, double groove design, as in roofing, interlocking at side joints, laid dry, with and including dismantling u/s AC sheet roofing, removing rubbish off the premises, complete all as specified and as directed. 5 M&L for Cement concrete Rusted Red/Grey colour Ridge cap of size 360mmx207mm x 240mm, with and including 15mm thick in roofing bedded and jointed in cement mortar 1:6, with and including dismantling u/s AC sheet ridge cap, removing rubbish off the premises, complete all as specified and as directed. 6 S&F Mild Steel Corrugated Galvanised Steel Sheet 0.45mm thick of class 8, grade of zinc coating 275, as in roof covering / ridges, hips, fixed with screws, complete all as specified and as directed. 7 S&F Rolled mild steel roof trusses (framed) trussed purlins, rafters, struts (beam, tee, angle channel, hallow sections or flat sections including distance pieces, cleats etc., conforming to grade Fe 410-W Gde E - 250 quality A, complete all as specified and as directed. 8 S&F Mild steel framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe-290 Gde- E-165, complete all as specified and as directed. 9 M&L for PCC type B0 [1:2:4] using 12.50mm graded granite stone aggregate) as in copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, finished plain fair faces, including demolition of old cement concrete of any type, complete all as specified and as directed. 10 S&F Aluminium Composite Pannel board of 4mm thick, comprising of a core containing not less than 70% non combustible mineral filling, sandwiched between two skins of 0.50mm thick aluminium alloy PERALUMAN-100 of weight not less than 7.6kg/Sqm, with all sub structures, anchors, hardware and all fittings, fixed with screwing & necessary scaffolding, fixed with screws / nails, with and including dismantling existing u/s boarding of any description, complete all as specified. 11 M&L for Preparation of new steel surfaces of any descriptionover 10cm width or girth and applyingtwo coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed. 12 M&L for False ceiling with High Pressure Steam Cured (HPSC) 4mm thick Non Asbestos Fibre Cement ceiling boards fixed with and including powder coated aluminium snap grid of size 605mmx605mm consisting of 25X25X1.25mm aluminium angles and TEEs of size 35x25x1.25mm with galvanised wire of required length and 6mm dia hanger grid suspended from trusses/ ceiling and purlins not exceeding 1200mm c/c both ways, with and including applying three coats of white wash on ceiling surface, with and including taking down existing u/s ceiling with frame work of any description, complete all as specified and as directed. 13 M&L for Pre-cast cement concrete solid block masonary type C1, 1:3:6 (using 20 mm graded stone aggregate) exc 10 cm width and setting in CM 1:6, with and including demolition of existing brick work of any description, complete all as specified and as directed. 14 M&L for Rendering 10mm thick on fair faces of new brick work or concrete surfaces of walls in CM 1:6 finished even and fair without using extra cement, complete all as specified and as directed. 15 M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces of walls in CM 1:6 finished even and fair without using extra cement, with and including taking down existing cement plaster of any description, complete all as specified and as directed. 16 M&L for 15mm thick Rendering on fair faces of brick work or concrete surfaces in two layers as 10mm thick in cement mortar 1:6 followed by 5mm thick in cement mortar 1:4 mixed with water proofing compound as per manufacturers instructions and finish the surface even and smooth without using extra cement, with and including taking down existing cement plaster of any description, complete all as specified and as directed. Note: Supply of WPC will be measured and paid separately. 17 Supply only Integral Water Proofing Compound. Make: Pidilite Industries Ltd Taloja / FOSROC / Dr Fixit / Asian paints 18 M&L for preparation of newly plastered surfaces of wall andapplying two coats of oil bound distemper over a coat of alkali resistant primer and 1mm thick wall case putty, complete all as specified and as directed. 19 M&L for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with siliconadditives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm with and including preparation of new plastered surfaces of any description, all as per manufacturers instructions, complete all as specified and as directed. 20 M&L for applying two coats of Oil Bound Distemper over a coat of primer and a layer of 3mm thick wall care putty on walls with and including complete removal of existing treatment on wall with wire brush, scrapping down smoke soot ,mould, moss and efflorescent salts, trading oil and greasy spots, filling holes & cracks with cement base putty and including preparation of old decorated surfaces of wall, complete all as specified and as directed. 21 M&L for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with siliconadditives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm with and including complete removal of existing treatment on wall with wire brush, scrapping down smoke soot ,mould, moss and efflorescent salts, trading oil and greasy spots, filling holes & cracks with cement base putty and including preparation of old decorated surfaces of wall, complete all as specified and as directed. 22 M&L for 75mm thick plain cement concrete 1:3:6type C1 (using 20mm graded hard granite stone aggregate) as in plinth protection, finished even and fair without using extra cement including making construction joints in 3 mtres interval and joint filled with sealing compound, with and including demolition of cement concrete (un-reinforced) as in ground floor, complete all as specified and as directed. 23 Taking down chowkats or frames n.exc 1.5Sq.m. with shutters (without taking off shutters from the frames) complete all as specified and as directed. 24 Taking down chowkats or frames exc 1.5 Sq.m. but n.exc 4.0Sq.m. with shutters (without taking off shutters from the frames) complete all as specified and as directed. 25 S&F 2nd class HW Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinnedat joints,supplied and fixed, complete all as specified. 26 S&F 35mm thick factory made 2nd class hard wood plain, framed, panelled shutters (two panels) with lock rail and panel of12mm veneered particle board with commercial veneering on both faces, size of rail and style as per IS - 1003 (Part I), kiln seasoned and chemically pressure treated, complete all as specified and as directed. 27 M&L for Factory made 2nd class hard woodGlazed and skeleton shutters , 35mm thick, open rebated and prepared to receive glass, gauze, etc. (with divided in to square with plain, chamfered or rounded, mitered and rebated sash bars any numbers), edge of framing plain, chamfered or rounded, fitted with cut and mitred beeds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.20 (a); supplied and fitted to chowkats, complete all as specified and as directed. 28 M&L for Factory made 2nd class hardwood 30mm thick glazed and skeleton shutters open rebated and prepared to receive glass, gauze etc for windows, ventilators for etc provided with stiles and rails anddivided into square with plain chamfered or rounded mitred andrebated sash bars any numberssize of members of shutters as specified in SSR Part-I Section 8 Clause 8.24(b) supplied and fitted to chowkats,complete all as specified and as directed. 29 M&L forpreparation of new or previously untreated surfaces of wood or wood based surfaces of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed. 30 M&L for preparing old painted wood or wood based surfaces of any description over 10 cm girth and width and applying one coat of synthetic enamel paint, complete all as specified. 31 S&F Galvanised mild steel wire cloth, 0.56mm dia of wire and average width of aperture 1.18mm and fixed with galvanised steel wire staples, and including 2nd class hard wood beads straight (any size) for glazed or gauged joinery, renewed including mitrted etc and painting exposed surfaces of beads with two coats of synthetic enamel paint over a coat of pink primer, complete all as specified. 32 S&F IN REPAIR Galvanised mild steel wire cloth, 0.56mm dia of wire and average width of aperture 1.18mm and fixed with galvanised steel wire staples, and including 2nd class hard wood beads straight (any size) for glazed or gauged joinery, renewedincluding mitrted etc and painting exposed surfaces of beads with two coats of synthetic enamel paint over a coat of pink primer, complete all as specified. 33 S&F Mild steel butt hinge, medium weight, cold rolled, 100mm long, ISI marked, complete all as specified. 34 S&F Mild steel butt hinge, medium weight, cold rolled, 75mm long, ISI marked, complete all as specified. 35 S&F IN REPAIR Mild Steel Helical door spring, 300mm long ordinary rat tail pattern spring, ISI marked, including roller and roller plate complete fixed to wooden/steel chowkats, complete all as specified and as directed. 36 S&F 150mm long Extruded aluminium alloy D type handles, fabricated type, anodised complete all as specified and as directed. 37 S&F 100mm long Extruded aluminium alloy D type handles, fabricated type, anodised complete all as specified and as directed. 38 S&F Aluminium anodised barrel tower bolt of extruded section of size 150mm long complete, complete all as specifiedand as directed. 39 S&F Aluminium anodised barrel tower bolt of extruded section of size 100mm long complete, complete all as specifiedand as directed. 40 S&F Aluminiumanodised sliding door bolt 300mm long with hasp & staple (Bolt type) and fixing clips of sheet cast or extruded section of cast aluminium alloy complete all as specified andall as directed. 41 S&F Sheet glass 4mm thick, ordinary quality and glazing with and including oil putty or wooden bead in squares not exceeding 0.5 Sq.m in each pane, including hacking out old glass, complete all as specified. 42 S&F Factory made powder coated aluminium sliding type window (Triple Track type), fabricated to required size with standard aluminium sections with bottom track of size 92x31.75x1.6mm, side & top frame 92x31.75x1.4mm, top & bottom shutter rail with 39x17x1.4mm, outer style of size 39x17x1.4mm, interlock style of size 39x27x1.4mm of approved make according to IS (thickness of powder coating not less than 50 micron) including necessary glazing clips, with and including 4mm thick sheet frosted glass for two shutters fixed with rubber gasket and SS wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm for wire mesh shutter fixed with aluminium beading, anodised aluminium fitting/fixture such as required number of rollers of suitable size, interlocking cleats/plates etc as required, complete all as specified and directed by the Engineer-in-Charge. Note : Quoted rate shall be inclusive of frame, shutter, sheet frosted glass, SS wire mesh and hardware such as butt hinges, tower bolts, handles, locking arrangement etc, complete as required at site. 43 M&L for Light Shade Coloured Vitrified Ceramic tiles 08mm to 10mm thick (square/rectangular) area of each tile exceeding 0.11Sqm but not exceeding 0.36Sqm, as in floors etc., laid over and including 15mm thick screed bed or bedding layer in CM (1:4), set and jointed in neat cement slurry and pointed in coloured cement to match, with and including demolition of existing floor tiles of any type with bedding mortar, complete all as specified and directed. 44 Supply, laying, testing and commissioning of LT XLPE insulated, screened with extruded PVC inner sheathed, PVC bedded, galvanised steel strip armoured electric FR power cable [heavy duty] of size 3.5core x 35.0Sqmm, with stranded aluminium conductor, 1100 volts grade, suitable for earthed system with and including cable glands, ferrules and connected accessories, laid in trenches or ducts or through the pipe etc., including taking down old u/s cable, complete all as specified. Note: Necessary excavation & earth work & cable protection pipe shall be measured and paid separately under respective items. 45 M&L for Double wall corrugated high density polymer (SDR 17) pipe of 63mm outer dia and 50mm inner dia, ISI marked, with and including necessary fittings like couplers, bends, end caps etc., laid in trenches /floors & fixed on wall/ pole with and including necessary fittings such as bends, sockets & other connected accessories, complete all as specified and as directed. 46 Earth work in excavation in trenches or drains (not exceeding 1.5m in width as well as 10Sqm on plan) not exceeding 1.50 m in depth, including dressing of sides and ramming of bottoms, lift upto 1.5m, as in all kind of soil, as in foundation, laying pipe lines / cables etc., complete all as directed by Engineer-in-Charge. 47 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil, as in any type soil, complete all as specified. [Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.] 48 Removal of excavated material [Soil] to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified. 49 M&L for Point wiring with 1.5 Sq.mm FRLSH PVC insulated unsheathed copper conductor cable, single core multi stranded 1100Volt grade conforming to IS 694: 1977, drawn in and and including PVC concealed rigid conduit (minimum 20mm) meadium grade ISI marked or including PVC casing & caping suitable size, ISI marked, with accessories, junction boxes, tees, terminal boxes with and including factory made PVC boxes with modular top cover plates with frame for switches / sockets etc., including one run of 1.5 Sq.mm single core FRLS PVC unsheathed copper conductor cable as earth continuity conductor and connected to common earth dolly, for one light / fan /bell point controlled by one way switch/MCB, including taking down old u/s point wiring of any type with fittings, complete all as specified and as directed. Note: Cutting chases and making good surfaces shall be included in the unit rate. 50 All as per Serial Item No. 49 here-in-before but for 3 pin 5/6Amp switch socket point, on same board, complete all as specified. 51 All as per Serial Item No.49 here-in-before but for 3 pin 5/6Amp switch socket point, on independent board, complete all as specified. 52 All as per Serial Item No. 49 here-in-before but with 2.5Sqmm copper conductor cable and 2.5 Sqmm cable as earth continuity conductor for 3 pin 6/16Amp switch socket point, on independent board, complete all as specified. 53 S&F Modular switch 1 way 5/6Amp, 1 Module, 240 Volts, complete all as specified and as directed. 54 S&F Modular switch 1 way 15/16A, 1 Module, 240 Volts, complete all as specified and as directed. 55 S&F Modular Socket, 5/6A, 2/3 pin combined , 2 module,240 Volts, complete all as specified and as directed. 56 S&F Modular Socket, 6A/16A, 2/3 pin combined multipurpose, 2 module, 240 Volts, complete all as specified and as directed. 57 S&F Modular BLDC Fan regulator, 240Volt, 120 watt electronic step & socket type regulator, 2 Module, for ceiling fan of any sweep, complete all as specified. 58 S&F Modular Bell push, 5Amp, 230Volt, white, 1 Module, complete all as specified. 59 S&F Ceiling rose, 3 terminals PVC/Polycarbonate, 3 phase, isolated body, complete all as specified and as directed. 60 S&F Ding Dong type Calling Bell, 230Volt, AC, complete all as specified. 61 S&F IN REPAIR LED luminaires 600mm x 600mm, 35/36 watt, 220Volt, >100 lum/W, PF>0.95, AC recessed / surface type with high efficiency PMMA diffuser soft glare free light, complete with driver and connecting up with three core flexible copper conductor cable of suitable size, complete all as specified. 62 S&F IN REPAIR LED Industrial Luminaries batten type fitting 1X20watt, 220Volt, >100 lum/W, PF>0.95, AC, integrated type batten, with driver and LED tube light and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified. 63 S&F IN REPAIR factory made epoxy powder coated distribution board double door TPN 4 ways (VTPN MCCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, strandard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one FP MCCB 100 Amps as incomer andSP/TP MCBs (or any combination of SP/TP MCBs ) as outgoings, complete all as specified. 64 S&F IN REPAIR LED Building Security light fitting 35Watts, 230 volts, >100lum/W, with Suitable size GI bracket made out of 32mm GI light grade pipe fixed with clamps, nuts&bolts etc., with IP 65/66 protection with LED lamp, driver, bracket with impact, corrosion resistant and all accessories, complete all as specified and as directed. 65 S&F Ceiling fan complete with blades, down rod, 3 blade type, 230Volt, 1200mm sweep, minimum air delivery 210 CFM with service value 6.0BEE, with brushless direct current motor (BLDC), five star rating, including taking down existing u/s ceiling fan and depositing to AGE E/M Store yard, complete all as specified and as directed. 66 S&F IN REPAIR MCCB, 3pole, 125 Amps, 415Volts, thermal magnetic, Ics=100% Icu, 16kA current rating conforming to IEC-60947-II along with spreader incl Phase Barreir to be fixed in distribution board, complete all as specified. 67 S&F IN REPAIR, Factory made epoxy powder coated sheet metal enclosure for DBs (Fixed flush to the wall), SPN, 415 volt,12Way, double door, IP-42 protection with 200 Amp rated copper bus bar 415Volt, and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s, complete all as specified. 68 S&F IN REPAIR MCB SPN 40 to 63Amp, 10kA, 230Volt, C curve with necessary connecting up in MCB DB, testing and commissioning, complete all as specified and as directed. 69 S&F IN REPAIR MCB SP 10 to 32Amp, 10kA, 230Volt, C curve with necessary connecting up in MCB DB, testing and commissioning, complete all as specified and as directed. 70 M&L for Circuit / Sub main wiring with two runs of 6.0Sqmm PVC FRLSH insulated copper conductor cable, single core multi stranded 1100Volt along with one run of 6.0Sqmm as earth wire, drawn through and including rigid PVC conduit of suitable size (minimum 25mm dia), concealed /surface type, medium grade as per IS 9537 (Part 1-1983) with conduit accessories, including taking down old submain wiring of any type, complete all as specified and as directed. Note: Two runs of cable, one run of earth wire and one run of conduit shall be measured as one unit. 71 S&F GI pipe light grade pipe 40mm dia for cable protection, complete on pole/walls/in road etc for cable protection, complete all as specified. 72 M&L for IN REPAIR Earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead 4mm GI wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of SSR Part-I, including excavation / earth work in any strata, adequate quantity of charcoal and common salt, PCC chamber with RCC 1:2:4 type B1 40mm thick cover slab with 8mm dia TMT bars @150mm c/c in bothways, suitable handle and angle iron frame of suitable size to fix the cover, with 20mm bore GI pipe light grade for watering with funnel, wire mesh and 15mm bore GI pipe medium grade for GI wire protection and 4mm GI earth wire, including testing after completion, complete all as specified and directed. Note : Earth wire will be measured after 7.5mtr from the earth strip or earth testing terminal block whichever is lesser under relevant item.

Key Value

Document Fees
INR 500 /-
Tender Value
INR 47.80 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail