| Sl. No. | Item Description |
| 1 | Demolition ofre-inforced cement concrete as in roofs ,floors (other than ground floors ) beams, stair cases,landings,chajjas and similar suspended works etc, (re-inforcement cut as required to facilitate demolition /dismental),including removal of debris complete all as specifed and directed by Engineer-in-Charge. |
| 2 | Completely removal ofexisting water proofing treatment ofany descriptions and in any position (APP membrane, etc) and including demolition concrete paddingwithtop layer of plaster, and rougheningof concrete slab by picking, sweeping clean and washing down with water to remove dust etc and applying evenly cement slurry at the rate of 3kg / sqm over cleaned roof surfaces complete all as specified and as directed by Engineer-in-Charge |
| 3 | Material and labour for PCC 1:2:4 type Bo (using 12.50mm graded stone aggregate) for roof,kerbs or mud stops,roundedor chamfered on eds etc including mixing of admixture fosroc SP 430 of M/S Fosroc chemical @ 250ml per 50kg of cement over existing roof and in padding concrete to maintain required slopecomplete all as specified and as directed by Engineer-in-ChargeNote:- Admixture will be measured and paid separetly under respective item. |
| 4 | Material and labour for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) for roof base of water tanks including mixing of admixture fosroc SP 430 of M/S Fosroc chemical @ 250ml per 50kg of cementcomplete all as specified and as directed by Engineer-in-Charge.Note:- Admixture will be measured and paid separetly under respective item. |
| 5 | Supply only of admixture fosroc SP 430 ,Dr fixit Chemical all as specified and as directed by Engineer-in-Charge |
| 6 | Material and labour for screed bed layer 10 mm thick in CM 1:4 onconcrete surfaces of roof, mixed with integral water proofing compound @ 3% by weight ofcement,finished even and smooth without using extra cementcomplete all asspecified and directed by Engineer-in-Charge. Note:- WPC will be measured and paid separetly under respective item. |
| 7 | Supplyliquidwater proofing compoundmake Fos roc or equivalent make |
| 8 | Material and labour for cleaning the entire roof surface thoroughly to remove all loose particles,dust/dirt particles and applying withone coat of industrial bitumen 85/25 grade at the rate of 1.20 kg/sqm over the plastered surfaces of roof, apply bituminious primer over bitumen surace and laid APP based polymeric membrane minimum weighing 3kg/sqm and minium 4mm thick reinforced with polyester non woven fabric (weight not less than 150 gms/ sqm) on primed surfaces by gas flame torch application and apply evenly industrial bitumen 85/25 grade at the rate of 1.20kg/sqmover APP membrane complete all as specified and as directed by Engineer-in-Charge. |
| 9 | Material and labour fortwocoatsAluminium paint over APPbased polymeric membrane complete all as specifiedand as directed by Engineer-in-Charge. |
| 10 | Dismantling of water tanks exc 250 & n exc500 ltr capacity and removing to store complete all as specified and directed by Engineer-in-Charge. |
| 11 | S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) triple layered 1000 ltrs capacity hoisted and fixed in positionincluding 25mm dia float ball brass valve and flynut complete, screwed for iron pipe or brass ferrule and fixed all as specified by Engineer-in-Charge |
| 12 | S&Fin repair25 mm dia gate /sluce valave fixed to pipe complete all as specified and directed by Engineer-in-Charge. |
| 13 | Taking down 15mm dia bore GI steel tubing and connection including cleaning and making good dismantaled surface complete all as specified by Engineer-in-Charge. |
| 14 | S&F CPVC pipes, SDR 11, 16 mm outer dia conforming to IS-15778 with all brass fittings such as Tee, bends, elbows, unions sockets andetc to receive the fittings and fixed with solvent on walls/ceiling or laying in floors complete all as specified by Engineer-in-Charge. |
| 15 | Cutting to brick wallschases, pinning in. making good to facings where required andpointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified by Engineer-in-Charge. |
| 16 | Taking down unservicable 25mm dia bore GI steel tubing and connection including cleaningand making good dismantaled surface complete all as specified by Engineer-in-Charge. |
| 17 | S&F GI tubing Medium grade25mm bore conforming to IS-15778 with all fittings such as Tee, bends, elbows, unions sockets and end oieces etc to receive the fittings and fixed withwalls laying in floors complete all as specified by Engineer-in-Charge. |
| 18 | Material and labour for repairing of soffits of slabs, chajja, facia and similar works by dismantling of loose/ disintegrated portion of RCC at any height (upto 10M) and in any sitution, including provn of support,formwork and welding of reinforcement and fixing in position and with provision of weld mesh, applying dubbing 1st coat of 20 to 25mm thick in CM 1:3 finished rough and finishing coat of 10mm thick in CM 1:3 finished even and smooth without using extra cementover and including cement slurry @ 3 kg/sqm, finished even and smooth to desired shapeand applyingtwo coats of weather proof exterior emulsion paint over a coat of arylic resistant primer to match with existing surfaces complete all as specified and directed by Engineer-in-Charge.(weld mesh measured and paid sepatrtely)Note:- (i) Unit rate of this item includes the cost of scaffolding, formwork etc. and nothing extra shall be paid on account of variation in height.(ii) For payment purpose, the area of finished plaster in 2nd coat shall be considered. |
| 19 | Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified by Engineer-in-Charge. |
| 20 | Material and labour for providing 75mm thick plain cement concrete (1:3:6) type C-1 , using 20mm graded stone aggregate , laid in 1:20 slope in alternate bays as in plinth protection, surface finished even and smooth without using extra cement, complete all as specified by Engineer-in-Charge. |
| 21 | Material and labour 75mm thick PCC 1:4:8 type D-2( using 40mm graded aggregate) thick as in sub base of floorsurface finished even & smooth complete all as specified and directed by Engineer-in-Charge. |
| 22 | M&L forchequered cement concrete with glossy finish tiles with grey cement and pigments 30cm x30cm x 22-25mm thick set and jointed in neat cementslurry in floors over and including 20mm screed bed in CM (1:6) complete all as specified and as directed by Engineer-in-Charge. |
| 23 | Dismantling of floor, hearth or wall tiling including cement mortar bedding complete all as specified and directed by Engineer-in-Charge. |
| 24 | S&F glazed ceramic coloured tiles (300mmx 450mmx7 mm) in vertical surfacesjointed in neat cement slurry and pointed in white cement. Incl cutting the tiles to the required size whereven required incl mitring the corners etc over 10 mm thick backing coats of cement plaster in CM (1:4) complete all as specified and directed by Engineer-in-Charge. |
| 25 | M&Lfor non Skid ceramic coloured tiles 7 to 8 mm thick (desined pattren) (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15mm thick in CM (1:6)for laying floor tiles complete all as specified and as directed by Engineer-in-Charge. |
| 26 | M&L for vertified ceramic tiles 9 mmthickjoint free double charged(light shade of square/ rectangular) polished,area of each tilesnot exc 0.36 sqmin floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to matchand including 15mm thick screed bed in CM 1:6 laying floor finished complete all as specified and directed by Engineer-in-Charge. |
| 27 | All as per above item no 26 but as in skirting over and including 10 mm thick backing coat with cement mortar 1:4 complete all as specified and as directed by Engineer-in-Charge. |
| 28 | Dismantling stone slabs and tiles of any descritpion or thickness in floors/skirting laid bedded in any mortar complete all as specified and directed by Engineer-in-Charge. |
| 29 | M&L machine cut granite16-20 mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match withshade laid over 15 mm thick screed bed in CM 1:6 complete all as specified and as directed by Engineer-in-Charge. |
| 30 | All as per Item No 29 here-in-before but in verticle surface over 10 mm thick backing coat in CM 1:4 |
| 31 | S&F machine cut and machine polished,green marble, 16-18mm thick in single piece as in cooking platform bedded, window cill,Jambs, Trade, Riser, landingetc jointed and pointed with neat grey cement slurry and pointed with coloured or white cement with pigment to match over and including sreed bedding15 mm thick in CM 1:4 all as specified and directed by Engineer-in-Charge. |
| 32 | All as per Item No 31 here-in-before but in verticle surface over 10 mm thick backing coat in CM 1:4 complete all as specified by Engineer-in-Charge. |
| 33 | Rounding to edges of stone slabs one edge such as in steps & platform etc |
| 34 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc, including raking out joints, hacking for key, scrubbing down with water etc. |
| 35 | Material and labour for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished fair and even without using extra cement complete all as specified by Engineer-in-Charge . |
| 36 | M &L for rendering 15mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:4, finished even and smooth without using extra cement, complete all as specified by Engineer-in-Charge. |
| 37 | M&L for rendering 5 mm thick cement plaster in CM 1:3on ceiling or concrete surfaces finished even and smooth (without using extra lime or cement) complete all as specified by Engineer-in-Charge. |
| 38 | M&L for preparation of new plastered surface of ceiling andapplyingthree coat of white wash complete all as specified and as directed by Engineer-in-Charge. |
| 39 | M&L for Preparation of old decorated surfaces of walls,Pillars, cornices etc by brooming down with steel wire brush, scraping down smoke shoot, moulds, moss and efflorescent salts and trading oil and greasy spots and applyingtwocoat of white wash on ceilingsetc complete all as specified and as directed by Engineer-in-Charge. |
| 40 | M&L forpreparation of new plasteredwall surfaceand applytwo coat of oil emulsion distember over a coat ofalkali resistance primer over two coats of white cement based wall care putty smooth finish etc of approved make & shadecomplete all as specified and as directed by Engineer-in-Charge. |
| 41 | M&L for complete removal of existing treatment of old decoratedwall surfaces and applying two coats of oil emulsion distember of approved shade over a coat of alkali resistant primer over two coats ofwhite cement based wall care putty, incl necessary scaffolding etc complete all as specified and as directed by Engineer-in-Charge. |
| 42 | M&L forpreparation of new plastered surface ofwallsand applying two coats of Dr fixit rain coat Classic and a coat of primer complete all as specified and as directed by Engineer-in-Charge. |
| 43 | Complete removal of existing treatment of external wall surfaces including removing fungus ,algae dirt, oil, grease and loose particles by wire brush,cleaning, washing with water jet machine,and applying with Dr fixitcrack filler by proper grooving, andapply two coats of Dr fixit (one coat rain coat water proofing+one coat rain coat classic top coat)of approved shade by Engineer-in-chargeover a coat of primer .The drying time of two coats will be6 to 8 hrs ,including all necessary scoffolding etccomplete all as specified by Engineer-in-Charge. |
| 44 | S&Fin repairStainless steel curtain rods 25mm bore SS -304 withornamental brackets, stops, complete all as specified and directed by Engineer-in-Charge. |
| 45 | S&F in repairstainles steel sink with drainage board , 1 mm thick sheet of steel grade AISI 304 for kitchen or laboratory, with plug, waste pipe, washers and wastes including bedding in cement morter to dwarf wall or including fixing CI cantilever bracket, connecting union to pipeetc., overall size 915 x 460 mm with bowl size 410 mm x 330 mm x 160 mm etc complete all as specified and directed by Engineer-in-Charge. Make : Nirali, Bule star ISI marked. |
| 46 | S&F in repairsstain less steel Wall MountedKitchen Utensils Dish Rack Stand With Plate & Cutlery Stand of Size(10 x31x48 Inches) Dish Stand/Holderthe sample approved and as directed by Engineer-in-Charge. Make:Palomino or equivalent |
| 47 | Dismantling plain or corrugated steel sheeting, any gauge, and thickness including Nainital pattern and roof covering, complete all as specified by Engineer-in-Charge. |
| 48 | S&F for Pre- Painted galvalume aluminiumzinc coating GI basedplain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping screws,including taking down complete all as specified and directed by Engineer-in-Charge. |
| 49 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified by Engineer-in-Charge. |
| 50 | S&F rooftrusses (framed), sunshade frames, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming to Fe-410-W(Gde-E-250)completeall as specified and directed by Engineer-in-Charge |
| 51 | Cutting chases,for concealed/fixing galvalume sheet etc., and making good, cutting notexc 10 cm girth pinning in. making good to facing of stone concrete block or slab wallswhere required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels,chajjas etc.;complete all as specified by Engineer-in-Charge. |
| 52 | S&F framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified by Engineer-in-Charge. |
| 53 | M&L for Preparation of newsteel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of anticorrosive painta coat primercomplete all as specified and directed by Engineer-in-Charge. |
| 54 | Taking down and refixing old existing iron grillswith the preparation of steel surface of any description, over 10 cm width or girth, not otherwise described and applying two coats of anticorrosive paintcomplete all as specified and directed by Engineer-in-Charge. |
| 55 | M & L for Preparation of old painted steel surfaces of any description having width/girth exceeding 10cm and apply two coat of anticorrosive paint complete all as specified and as directed by Engineer-in-Charge. |
| 56 | Taking downchowkats of wooden/steel/aluminium/doors ,windows,ventilations complete with frames and shutters (without taking off the shutters and guard bars) of area not exc 1.5 sqmcomplete all as specified and directed by Engineer-in-Charge. |
| 57 | Taking downchowkatsof wooden/steel/aluminium/doors ,windows ,complete with frames and shutters (without taking off the shutters grills and guard bars) of area exc 1.5 sqm and not exc 4.00 sqmcomplete all as specified and directed by Engineer-in-Charge. |
| 58 | S&F Solid WPC frame (Single Rebated) of approved colour of size 50mm x 75mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheetmetal CSK screws complete all as specified and as shown on drawing (Note :- Door frame shall be waterproof, termite proof, elegant and should have excellent screws holdingstrength to fix hinges and hold doors properly for a long life) complete all as specified. |
| 59 | S&FFactory Made 24 mm thick 100% Solid WPC ( Wood polymer Composite ) LaminatedFlush door Shutter of required size and colour(one side decorativeother side plain )comprising of virgin PVCand Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) having good screw holding capacity Minimum Compissive of 50 N/mm2,of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant complete all as specified. |
| 60 | S&F factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50mm x 100mm of requiredsize and coloured comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximumoxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawaltrength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardantand fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia andlength complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid forseparately). ® Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. complete all as specified and as directed by Engineer-in-Charge. |
| 61 | Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhatcoloured of size 65x125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximumoxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawaltrength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardantand fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia andlength complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid forseparately). ® Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. complete all as specified and as directed by Engineer-in-Charge. |
| 62 | S&FFactory made30 mm thick single extruded WPC (Wood Polymer Composite) both sidedecorative of solid shuttercomprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. Note: stainless steel butt hinges and necessary S S screws shall be paid separately), |
| 63 | S&F Providing 30mm thickfactory made wire mesh solid WPC door shutter both side decorative /laminated structureconsisting of Density 500 Kg /Cbm Manufactured by an ISO-9001-2015 certified Company , Door to be panelled with SS mosquito Mesh and XTN aluminium Mesh for additional strength and safety purpose. (confirming as per IS:4020). The door should be water proof, termite proof, fire retardant and having screw holding capacity. Door to be fixed to frame with 3 nos. M.S powder coated butt hinges size 100mmx25mmx2mm and 32mm long steel screws drilled suitable to pass through both the walls of the M.S tube.Other hardwares should be fixed with 19x6mm size steel screws etc. Complete as per direction of Engineer-in -charge, manufacturer\"s specification & drawings. |
| 64 | S&F Powder coated aluminium three track, three shutter (equal width) type window miniumum 50 micron anodised with frame made of aluminium sections of size 91.80 x 31.75 x 1.0mm and shutters made out of aluminium sections 39.4 x17.7 x 1.0mm without sash bars including necessary jointing cleats, glazing clips, rubber packing, anodised snap beadings, screws aluminium fittings lockings arragngements etc including 4.00mm thick sheet glass for glazed shutters and stainless steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40mm for wire gauge shutter all as specified and as directed by Engineer-in-Charge, complete all as specified by Engineer-in-Charge. |
| 65 | S&Fpowder coated aluminium ventilator partly fixed and partly louvered type without sash bar section as per minimum 50 micron anodised including necessary jointing, clip, rubber packing, anodised snap beading crews and 4mm thick pin headed glass etc complete. |
| 66 | S&F 300 mm long stain less steelsliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed Complete all as specified and as directed by Engineer-in-Charge. |
| 67 | S & F 100 mm sizestain less steel Butt hinges,with mild steel hinge pin, bright polished and fixed, typeB-11 Complete all as specifiedand as directed by Engineer-in-Charge. |
| 68 | S&F 150mm long stain less steelhandles, Complete all as specifiedand as directed by Engineer-in-Charge. |
| 69 | S&F Stain less steel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed 200mm long complete all as specifiedand as directed by Engineer-in-Charge. |
| 70 | S&F 150mm Floor door stopper of brassbody and tongue with hard drawn steel spring fixed in floor complete all as specified and directed by Engineer-in-Charge. |
| 71 | S&F PVC Pre - laminated factory made kitchen cabinet &cub board shutter with frameof 18 mm thick approved colour /shed quality and make made from PVC one side pre laminated sheet .The exposed edges shall be sealed with PVC edges beading of same shed and colour, the shuttershall be fire retradent having necessary screws & sliding chennals forholding capacity,Shutter shall be fixed to frame using approved hinges with necessary stain less steel screws, stainless steel handles not less than200mm longandincluding taking down kitchen cabinet/ cub bord shutters with frameof any description etccomplete all as specified andas directed by Engineer-in-Charge. |
| 72 | S&F 75 mm stainless steel butt hinges complete all as specified and as directed by Engineer-in-Charge |
| 73 | S&F 150 mm long Extruded brass handles, fabricated type polished Complete all as specified and as directed by Engineer-in-Charge. |
| 74 | S&F Magnetic cather for cupboard fixed with fixing arrangement complete all as specified by Engineer-in-Charge . |
| 75 | S&F in repair 20 mm dia Stain less steel rod with bracketsfixing in cupboard complete all as specified by Engineer-in-Charge. |
| 76 | S &F, in repairs, aluminium alloy wire cloth,0.45 mm nominal dia ofwire and average width ofaperture 1.40mm and fixed with in wooden windows, doors etc,and fixing of teak wooden beedingcomplete all as specified and as directed by Engineer-in-Charge. |
| 77 | Takingdownand refixing same woodendoor shutters exc 1.0 sqm but not exc 2.0 sqmincluding all fittings complete all as specified by Engineer-in-Charge |
| 78 | M&L for preparation of old painted wood surfaces of any description having width/ girth execeeding 10cm and apply one coat of synthetic enamel paint complete all as specified & as directed by Engineer-in-Charge. |
| 79 | Dismantiling and removing sunken slab filling of brick bats/cinder/light weight concrete including plastering on sunken floor/sides of floor slab/tiles of toilets in all the floors including all the water and sanitary fixtures and removing all rubbish/debris outside MoD land as per instruction complete all as specifiedand directed by Engineer-in-Charge. |
| 80 | M&L for the suken floor RCC slab including sides to the full extent of sunken portion in upper floor shall be prepared and plastered with 15 mm thick cement plaster in CM 1:3 with water proofing compound as per manufacturer\"sinstructions and finished even and smooth without using extra cement. When the plaster is cured and dried up, apply a uniform coat of blown grade bitumen 85/25 @ 1.2 kg/Sqm confirming to IS 702 over a coat of primer @ 0.70 Kg.Sqm over plastered surface complete all as specified and as directed by Engineer-in-Charge.Note :- Integral water proofing compound shall be measured and paid separately as \"Supply only\". |
| 81 | Water proofing treatment to Sunken floor slabe complete as specified bellow and as directed by Engineer-in-Charge.(a) Provide and lay 4mm thick APP modified torch applied prefabricated five layer water proofing membrane weight not less than 3.60 Kg/Sqm.(b) Apply a uniform coat of blown grade bitumen 85/25 @ 1.2 Kg/Sqm confirming to IS 702 of the surface area complete all as specified by Engineer-in-Charge. |
| 82 | M&L for PCC lean concrete 1:5:10 type E2 laid in layers of not more than 100 mm thick tamping etc complete all as specified and directed by Engineer-in-Charge. |
| 83 | M&L for 40mm thick PCC 1:2:4 type B0 (12.5 mm graded )stone aggregate as padding concreteetc over lean concrete complete all as specified by Engineer-in-Charge. |
| 84 | S&F in repairVitreous china wash down water closet (Padestal pattern) pan white including bolts and flush pipe, pedestal pan and trap including connections to drain (or outgoing pipe) and flushing pipe etc including seat coverclosed typecomplete all as specified by Engineer-in-Charge. |
| 85 | S&F in repair10 litre PVC valveless, duel function syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified. |
| 86 | S&F in repairVitreous china white flat back of size 550x400 mm wash basins, vitreous china (flat back or angle back type) any size, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe including 32 mm dia CP waste fitting complete all as specified and directed by Engineer-in-Charge. |
| 87 | S&F in repairPVC connection low density polythene pipe 15mm dia, 450mm long, heavy duty with PTMT nuts. |
| 88 | S&F in repairs Bib taps, fancy type, chromium plated Quarter turnwith crutchsc-rewed down, screwed for iron pipe or for brass ferrule and fixed 15 mm bore complete all as specified and as directed by Engineer-in-Charge. |
| 89 | S&F in repair Pillar taps, fancy type, chromium plated, Quarter turns crewed down, high pressure, with or without lettered ‘Hot\" or ‘Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed 15 mm bore complete all as specified and as directed by Engineer-in-Charge. |
| 90 | Supply and fixing in repairchromium plated tubular towel rail 20mm dia \"D\" type 60 cm long between flanges complete all as specified and directed by Engineer-in-Charge. |
| 91 | S&F in repairs15mm borebrass CP Mixer Quarter turns for mixing hot and cold water screwed iron /PVC pipewith long screwed shanks and fly-nuts, complete all as specified and as directed by Engineer-in-Charge. MakeCera/jaquar or equivalent. |
| 92 | S&Fin repair15mm stop cock/ angle cock cast copper alloy, fancy type chromium plated, screwed down, high pre-ssure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed by Engineer-in-Charge. Cat pot No:F1015211or equivalent |
| 93 | S&F in repair soap dish of any typefixed to plugs with chromium platedwith brass screws complete all as specified and directed by Engineer-in-Charge. |
| 94 | S&F in repairs health faucet (ABC) mild steel chromium plated suitable for 15mmdia pipie with 1.25m long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified by Engineer-in-Charge. |
| 95 | S&F in repairs 600 X 450mm bevelled edge mirror, 5mm thick selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed with wooden plugs to wall with chromium plated brass screws and cup washers complete all as specified and as directed by Engineer-in-Charge. |
| 96 | S&F in repairs brass chromium plated shower rose with or without swivel joints 75mm size, including fixing to steel pipe or union complete all as specified and as directed by Engineer-in-Charge. |
| 97 | S&F in repairPVC (SWR) bends of 110mm bore with access door complete all as specified by Engineer-in-Charge. |
| 98 | S&Ffor PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors/walls, 110 mm bore including taking down existing pipecomplete all as specified by Engineer-in-Charge. |
| 99 | S&FPVC (SWR) Nahani /Floor trap, 75 mm dia of out let, plain with grating including jointing to waste pipe with solvent and cement concrete type B1 (1:2:4)including removing old trap complete all as specified and as directed by Engineer-in-Charge. |
| 100 | S&FPVC (SWR) gully trap , 125/110 mm dia of out let, plain with grating including jointing to waste pipe with solvent and cement concrete type B1 (1:2:4)including removing old trap complete all as specified and as directed by Engineer-in-Charge. |
| 101 | S&F for PVC (SWR)75mmpipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors or wallsincluding taking downexisting pipe complete all as specified by Engineer-in-Charge. |
| 102 | S&F in repairPVC (SWR) bends of 75mm bore with access doorcomplete all as specified by Engineer-in-Charge . |
| 103 | S&F in repairPVC (SWR) branch piece double Y equal or unequalof 75 mm bore in radius complete all as specified by Engineer-in-Charge. |
| 104 | S&F in repairPVC (SWR) branch piece double Y equal or unequalof 110mm bore in radius complete all as specified by Engineer-in-Charge. |
| 105 | S&F in repair 100mm stain less steel gratingscomplete all as specified by Engineer-in-Charge. |
| 106 | Excavation in trenches, n exc 1.50 mtr wide and n exc 1.50 mtr in depth, for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 Sqm on plan and n exc 1.50 mtr in depth and getting out in hard densesoil complete all as specified. |
| 107 | Returning filling in soft/loose soil,including spreading, leveling, watering and well ramming in layers n.exc 25 cm complete all as specified by Engineer-in-Charge. |
| 108 | Removing excavated material / soil exc 250 m but n. exc 500 m and depositing whereasdirected by Engineer-in-Charge. |
| 109 | M&L for reinforced concrete pipes class NP-2 ,150 mm dia laid and jointed coplete with collars and including demolition and breaking up Existing SGSW/RCC/SWRpipes concrete bed including packing under and haunchingjointed in cement mortar and taking out of trenches if requiredetc,complete all as specifed and directed by Engineer-in-Charge. |
| 110 | M&L for concrete bed to 150 mm dia pipes of cement mortar 1:3:6 type C-2 including packing under and haunching against the side of pipes after they are laid and tested complete all as specifed and directed by Engineer-in-Charge. |
| 111 | Demolition of brick work/stone masonry built in cement mortar including all quoins arches, pillars all as directed by Engineer-in-Charge. |
| 112 | M&L for brickwork with subclass \"B\" bricks, straight or curved on plan exc 6m mean radius, built in cm 1:6complete all as specified by Engineer-in-Charge. |
| 113 | Material and labour rendering 15mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces in septic tank and man hole external & internalfinishes the surfaces even and smooth without extra cement coat including using water proofing compound 3% by weight of cement etc complete all as specified & directed by Engineer-in-Charge. (Note :-Supply only water proofing compound will be measured and paid separately) |
| 114 | supply only water proofing compound |
| 115 | M&L for providing reinforcedcement concrete 1:2:4 type B1 using 20mm graded stone aggregatein cement mortat 1:4 as set in cover slabs ,roof,floor slab, etcincluding framed work for man holes etc including weathering ,slightly rounded or chamfered angle and throating as directed by Engineer-in-Charge including necessary form work complete all as specifed and directed by Engineer-in-Charge. |
| 116 | M&L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, slabs, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality confirming to TMT bars complete all as specified by Engineer-in-Charge. |
| 117 | Material and labourfor TMT bars 6- 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge. |
| 118 | Taking down carefully unserviceable aluminium/copperpoint wiring (light, fan, socket or power)including unserviceablelight fittings, switch board complete,switch sockets, ceiling roses, pendants, regulators, sockets, etcandremoving materials from site and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Engineer-in-Charge. |
| 119 | M & L for Point wiring with 1.5 Sqmm (nominal area), FRLS PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and includingproviding PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLS PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box fixed with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and directed by Engineer-in-Charge. (a) One light point or one fan pointor bell point controlled by one switch |
| 120 | All as per item No 119 here-in-before but one 3 pin socket outlet, 5 Amp on independent board. |
| 121 | All as per item No 119 here-in-before but one 3 pin socket outlet, 5 Amp on the same board with other switches |
| 122 | All as per item No 119 here-in-before but one bell/buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5 sq mm size. |
| 123 | All as per item No 119 here-in-before but wiring with cables of size 2.5 sqmm for wiring & cables of size 2.5 sqmm both (FRLS) as continuous earth wire for one 15 Amps, 3 pin Switch/Socket outlet on Independent board complete all as specified and directed by Engineer-in-Charge. (Note : cutting chases & making good of disturbed surfaces are including in the quoted rate. |
| 124 | S & F switch piano, 5 Amp, single pole, flush type one way 230 volts complete all as specified and as directed by Engineer-in-Charge. |
| 125 | S & F socket out let, 2 in 1, 3 pin,5 Amps, 240 volts complete all as specified and directed by Engineer-in-Charge. |
| 126 | S & F Switch socket combination, 2 in 1,5 Amps,flush type, 240 volts complete all as specified and directed by Engineer-in-Charge. |
| 127 | S & F Switch socket combination, 5 in 1, 5/15 Amps, 240 volts, flush type with fuse & neon indicator complete all as specified and directed by Engineer-in-Charge. |
| 128 | S & F Ceiling rose, 3 way PVC insulated bodycomplete all as specified and directed by Engineer-in-Charge. |
| 129 | Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. Make: Bajaj,Philips,Havells |
| 130 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. Make: Crompton or equivlent Bajaj/Philips/Havells |
| 131 | S/F switch bell push, flush type 5 Amp. |
| 132 | S&F bell, electronic type AC, 230 Volts single pole. |
| 133 | S&F lamp holder, PVC/ poly carbonate type with black plate suitable for batten fittings. |
| 134 | Supply and fix new adore LED lamp 9 Watt confirming to Cat No LHLDBWH4L8R009 of Havell\"s or euivalent in Philips / Bajaj |
| 135 | Supply and fixing in replacement ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)complete all as directed by Engineer-in-Charge.Note: all existing fan taking down and deposited to MES store. Make:Bajaj,Havells,Crompton. |
| 136 | Supply and fix exhaust fan, steel bodyAC single Phase. 230V of size 300m sweep with, blades, and frame and louvers Complete all as directed by Engineer-in-Charge Note: all existing fan taking down and deposited to MES store. Make:Bajaj,Havells,Crompton. |
| 137 | S&F fan regulator electronic step type complete all as directed by Engineer-in-Charge at site |
| 138 | Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.Make: Crompton or equivlent Bajaj/Philips/Havells |
| 139 | Taking down electric meter of any type and any make single/three phase by dismantling of all electrical connection checked the meter ,and Refixed same Nos of meter on wooden board in metal box of suitable size in same Nos of qtr after repairworks completed Note : All spare items and welding work price including in the coated rate. |
| 140 | S&F in replacemen MCB DB SPN 8 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surfaceall as specified and directed by Engineer-in-Charge |
| 141 | S&F in repairs MCB SPN 40 to 63 AMP,240 Volts 10KA \"C\" curve ,Complete all as specified and directed by Engineer-in-Charge. |
| 142 | S&F in repairs MCB SP 5 To 32 AMP,single pole 240 Volts 10KA \"C\" curve, Complete all as specified and directed by Engineer-in-Charge. |
| 143 | M&L for sub main wiring drawing through PVC casing and capping with four runs of single core 6 sq mm and two runs of 6.0 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts gradeall as directed by Engineer-in-Charge.Note:- Two run of 6 sqmm wire and One run of 6 sqmm wire and One run of PVC casing caping will be measured as one running meter. |
| 144 | S&F in replacement Triple pole and neutral (8 Way) Double door,(VTPN) suitable for and including MCCB 4 pole, 160 amps, 16 KA as incoming (compact) Earth and neutral bus bar of capacity upto 200 amp 8 ways,IP 43 protection , shrouded neutral bar & pan assembly with flexible connecting link in the wall with suitable nut and boltincluding matching the existing surfaceall as specified and directed by Engineer-in-Charge , Make Havells (DHDLVDOBGSFE08)HSN CODE 8537 or equivalent indoasian/Standered. |
| 145 | M&L for earthling complete with galvanized GI earth plate electrode of size 600x600x6.00 mm, buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of volts, nuts, check nut and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate as shown in electrical plate No 3 of SSR part1991,20 mm dia watering pipe medium grade 1.50 mtr long GI protection pipe light grade 15 mm dia from earth pit to main board (NOTE:- maximum length of GI protection pipe with each earth shall not be less than 7.5 mtrs) including necessary pit with cover , including testing on complition. |
| 146 | M & L for cutting/making hole for fixing of ser item No 136 and making good disturbed surface with existing surface all as specified and directed by Engineer-in-Charge. |
| 147 | S &F Sheet Metal single pole and neutral enclosure with a two pin and earth plug and socket complete with one doublepole MCB of capacity 20 A SPN. Make : Standard/Havells |
| 148 | M&L for sub main wiring drawing through PVC casing and capping with Wiring alongwith earth wiresize2x2.5 sq. mm + 1x2.5 sq. mm earth wireof FRLS is PVC insulated copper conductor, single core cable in surface/recessed as required .Note:- Two run of 2.5 sqmm wire and One run of 2.5 sqmm wire and One run of PVC casing caping will be measured as one running meter. |
| 149 | Supply and lay in trenches / along the wall / floor / on poles / pillars / for road / Nallah crossing,pipes GI light grade of size 50 mm dia with and including all fittings and accessories complete including taking down the old unsv all as specified and and directed by Engineer-in-Charge for cable protection |