Tender For Addn Altn To Certain Cafeterias In Tech Area At Af Stn Jammu Under Ge Af Jammu; 1 Demolition of brick/stone masonry built in cement mortar and removefrom the site complete all as specified and directed. 2 Taking down cement or cement lime plaster, any description on brick or stone walls etc including raking out joints, hacking for keys, scrubbing down with water etc, including cutting of trees, shrubs or any type of vegetation upto and including roots upto 6.00 mtrs hight form ground complete all as specified and directed.Note: Taking down wall tiles including plaster & backing cement mortar up brick surface without any extra charge to Govt. 3 Taking down chowkats or frameswith shutters(without taking offshutters from frames) area n-exc 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), complete all as specified and directed by Engineer-in Charge. 4 Demolition of unreinforced cement concrete in ground floors and paving n.exc 15cm thickness (below or above ground level) and removing demolished material to a distance and depositing to the distance exceeding 50 metres but not exceeding 100 metres where directed at a level not exceeding 1.5 metre above the starting pointcomplete all as specified and directed by Engineer-in-Charge. 5 Demolition reinforced cement concrete of any depth in any position complete all as specified and directed. 6 Taking up or down steel tubing for 15mm dia pipe and connections including cleaning for re-fixing or removal to store.all as spd and directed by Engg-in-Charge 7 Taking up or down steel tubing for 20mm dia pipe and connections including cleaning for re-fixing or removal to store.all as spd and directed by Engg-in-Charge 8 Dismantling 1000 ltr water tanks and removing to store complete all as specified. 9 Demolition and breaking up drain 200mm dia pipes (Salt glazed stone ware, PVC, AC or reinforced concrete) set in cement mortar complete all as specified and directed by Engr-in-Charge. 10 Excavation of trenches n.exc 1.5m wide and n.ex 1.5m in depth for foundation etc or for shafts , wells cesspits manholes , pier holes etc n.ex 10sqm on plan and n.exc 1.5m in depth and getting out in any type of soil complete all as specified. 11 Excavation in post holes (or similar holes) each n exc 0.5 cum,and removing surplus soil to distance n exc 50m and making good surface of any type of soil. 12 M&L for 100 mm thick plain cement concrete 1:4:8 type D2 (40mm graded crushed stone aggregate) as in sub base of flooring complete all as specified and as directed by Engr-In-Charge. 13 Brick work using old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6),complete all as specified and directed by Engineer-in-Charge. 14 M&L brickwork with subclass ‘B’ bricks, straight or curved on plan to anyradius in half brick thick walls built in CM 1:3 complete all as specified and directed by Engineer-in-Charge. 15 S&F flush shutters, solid core construction 30mmwith block board core and plywood face panels, commercial type on both sides complete all as specified and directed. 16 M & L for 2nd class hard wood timber scantling plain fillets square, rectangular in section area exc 13 Sqcm and not exc 25 sqcm secured with nails complete all as specified. 17 M & L for 2nd class hard wood timber scantling plain fillets square, rectangular in section area n-exc 3 Sqcmsecured with nails completeall as specified. 18 S&F 18mm Particle board, medium density, flat pressed, single layer type or three layer type with BWR type adhesive, fixed with screws to timber frame work complaete all as specified 19 S&F Sun-mica High Pressure Laminate Sheet, Thickness: 1 mm all as per fixing manufacturer instruction complete all as specified.Note: Material shall be produce to GE for approval before Execution . 20 Continuous (piano) hinges width of flaps 40 mm when opened, mild steel, bright finish or electrogalvanisedcomplete all as specified and as directed. 21 S&F 125mm hasp & staple safety type of aluminum with mild steel hinge including bolt to hinge plate and fixed with screw complete all as specified and directed. 22 S&F for magnetic catcher with steel body ‘H’ type, fixed to shuttercomplete all as specified and directed. 23 Providing and fixing Factory made single extruded WPC (Wood / Polymer Composite) solid door/ window/Ceosetory windows & other Frames/ Chowkhat of size 50x 100 mm comprisingof virgin PVC polymer of K value 58-60(Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms)fabricated with miter joints after applyingPVC solvent cement and screwed with fullbody threaded star headed SS screwshaving minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N(Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules ofelasticity 900 N/mm2 and resistance to spread of flame of Class A category withproperty of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia andlength complete as per direction ofEngineer-in-Charge. (M.S. hold fast/ lugsor SS dash fasteners shall be paid forseparately). Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall beacceptable. Variation in profile dimensionson plus side shall be acceptable but no extrapayment on this account shall be made. 24 All as per srl Item No 23 above but Frame size 50x125mm complete all as specified. 25 S&F Factory Made Solid PVC Moulded Door Shutter with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 5mm thick Moulded Prelam PVC Sheet on the front face & 5mm prelam PVC Sheet on back face, complete all as specified. 26 S&F in repair powder coated to minimum thickness of powder coating 50 micron of aluminium frame for doors, windows, ventilators with one or more rebates including jointing cleat for fixing etc, complete in all respect as per manufacturers instruction and including making good disturbed surfaces complete all as specified and directed by Engineer-In-Charge. 27 S&F repairPowder coated/anodised aluminumhandle cast type 100mm collapsible type complete all as spfd. 28 S&F in repair Powder coated/anodised 75mm size butt hinges , extruded aluminum alloy ISI marked all as spfd. 29 S&F in repair Aluminiun anodised barrel tower bolts, ISI Marked, of extruded sectionof size 100mm fixed in repair complete all as specified and directed. 30 S&F in repair Neoprene/ EPDM rubber gasket for fixing sheet glass complete all as specified. 31 S&F in repairfor 5.50mm thicktinted sheet glass or frostedglasswhich will be required ordinary quality and glazing with oil putty/ wooden beads with nails in square exceeding 0.5 Square metre in each pane etc complete all as specified and directed. 32 M&L for 12mm thick Aluminium Composite Panel Board (ACP) both side coloured of decorative choice colour fixed with screws, cleats as required for frame work complete all as specified and directed by Engr-in-Charge. 33 S&F in repair Stainless steel (SS) 150 mm size butt hinges , extruded aluminum alloy ISI marked complete all as spfd. 34 S&F in repair Stainless steel (SS) 300mm longsliding door bolt with and or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn SS bolts and fixed 35 S&F in repair Stainless steel (SS) handle cast type 150mm collapsible type all as spfd. 36 S&Fin repairfor Floor door stopper of aluminium alloy body and tongue, anodized, with hard drawn steel fixed in floor with over all length of cover plate 140 mm fixed in repairs complete all as specified and directed. 37 S&F in repairaluminium die cast body door closed hydraulically regulated designation No. 2 universal type (ISI Make) suitable for door shutters of weight between 36 to 60 Kg fixed in repair complete all as specified and directed. 38 Rendering 10mm thickon fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) on walls in cement mortar 1:6, complete all as specified and directed by Engr-in-charge. 39 Rendering 15mm thickon fair faces of brick work or concrete surfaces, other than fair face(without using extra cement) on walls in cement mortar 1:4 including WPC complete all as specified and directed by Engr-in-charge.Note: Supply only liquid water proofing admixture shall be measured and paid seperately 40 Supply only LiquidWater Proofingadmixture complete all as specified and directed by Engineer-in-Charge. 41 M & LGlazed ceramic tiles coloured (350x250x7mm/ 450x350x7mm) for works on vertical surfaces such as skirting/dados of economy class B-III conforming to IS-13712 etc set and jointed in neat cement slurry and pointed in coloured cement to match including rendering 10 mm thickin cement mortar 1:3, as in backing layer without using extra cement complete all as specified. 42 25 mm thick, Plain cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in sub base for laying floor finishes including finishing the surfaces even and rough without using extra cement, complete all as specified and as directed by Engr-in-Charge. 43 M&L for non skid coloured ceramic tiles7to 8 mmthick, area of each tileexc 0.11 Square metre but n exc 0.18 Square metre in floors etcset and jointed in neat cement slurry and pointed in colored complete all as specified and directed.Note : Tiles will not be used before they are approved by GE and All pattern will be used digital or non digital tiles are required on ground without additional charge. 44 M&L for 15mm dia bore galvanized steel water tubing, “medium grade,” together with all fittings; (ISI marked) such as elbows, bends tees, nipples, union sockets, sockets etc and short pieces and fixed complete to walls and ceilings or laid in floors complete all as specified. 45 Re fixing only 15mm dia bore galvanized steel water tubing, “medium grade,” together with all fittings; (ISI marked) such as elbows, bends tees, nipples, union sockets, sockets etc and short pieces and fixed complete to walls and ceilings or laid in floors complete all as specified. 46 M&L for 20mm dia bore galvanized steel water tubing, “medium grade,” together with all fittings; (ISI marked) such as elbows, bends tees, nipples, union sockets, sockets etc and short pieces and fixed complete to walls and ceilings or laid in floors complete all as specified and dirceted. 47 Re fixing only 20mm dia bore galvanized steel water tubing, “medium grade,” together with all fittings; (ISI marked) such as elbows, bends tees, nipples, union sockets, sockets etc and short pieces and fixed complete to walls and ceilings or laid in floor complete all as specified and dirceted. 48 S&F Rotational moulded polyethylene water storage tank, inner and out white, two layers, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 1000 litres each including all accessories (i.e GI nipples, etc), including provn of 20/15mm dia spout for connecting inlet, outlet, overflow and washout pipes,complete all as specified and as directed by Engr-in-Charge. 49 S&F 20mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipeand fixed (Minimum weight210 gram), fixed in repairs, complete all as specified and as directed by Engineer-in-Charge. 50 S&F Stop valve/cock, Fancy TypeISI Marked, cast copper alloy, screwed down, high pressure with handle, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, fixed in repairs, complete all as specified. 51 S&F in repairPVC grade Apipes 100 mm bore single socketed, in any length with rubber ring joints, laid in trenches and jointed on concrete bed complete including testing etc complete all as specified. 52 S&F in repair PVC grade Apipes 75 mm bore single socketed, in any length with rubber ring joints, laid in trenches and jointed on concrete bed complete including testing etc complete all as specified. 53 M&L in repair 100 mm PVC (SWR) bends any radius complete all as specified. 54 M&L in repair75 mm PVC (SWR) bends any radius complete all as specified. 55 S&F 75mm bore PVC (SWR) floor trap, plain with grating including jointing withsolvent cement complete all asspecified. 56 S&F in repair 75mm bore PVC (SWR) multi floor trap with grating including jointing with solvent cement complete all as specified. 57 S&F in repair Stack clamps 75/100mm diafor out of 50 mm by 5 mm flat iron round 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roofwith proper mannercomplete all as specified and directed. 58 M&L for 200mm thickconcrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 for 150/200 mm SGSW pipes complete all as specifiedand as directed by Engr-In-Charge. 59 S&F in repair 50mm bore asbestos cement pipes in any length with cement joints; fixed to walls complete all as specified. 60 S&F in repair 50mmCone cap cowl complete all as specified. 61 Supply & fixing in repair PVC Flushing Cistern 10 litre capacity, Low Level Valve Less, Symphonic Action type, White, with Inlet, Ball Valve, Float and Handle including 32mm dia PVC Flush Pipe, a Pair of MS Brackets,CP flush bend including Cutting and Pinning in Ends, Making Good Disturbed Surfaces in Cement Mortar 1:3 including taking down unserviceable Flushing Cistern and connected Items of any description, complete all as specified and as directed. 62 S&F Plantex Double Bowl Sink for Kitchen/Heavy Duty Stainless Steel Sink with 25 Years Warranty by Plantex/Handmade Kitchen Sink with Drying Rack, Hose Pipe and Coupling (Silver Matt - 32x18x9 Inches), complete all as specified and as directed by Engr-in-Charge.Note:-1 piece of double bowl kitchen sink, 2 piece of sink coupling, 1 piece of drain rack, 2 pieces of hose pipe and 1 piece of double bowl connector.2. (l) 81 x (w) 45.5 x (h) 22 cm, and Bowl dimension is (l) 40.5 x (w) 37 x (h) 22 cm with adjustable drain rack can be used to wash fruits and vegetables, can be used as a drying rack for tableware. 63 M&L for Granite work 18-20mm thick (Table rubbed and polished) in cooking platforms over10mm thick screed bedin cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shede complete all as per specified and as directed.Note : Including making of hole and other work as per directon by Engr in Chargewhich is required without additional charge. 64 S&F Under counter basin with fixing accessories assemblywith manufacturar instruction complete all as specified.Make :Cera Cat No : F5003109 or equivalent in approved makes 65 S&F bottel trap 32mm size with 250mm and 190mm long wall connection pipes with complete all fittingassceceriseas per manufaturar instruction complete all as specifiedand directed.Make Jaquar Cat No:ALD-WHM-769L250X190 or equivalent in approved makes 66 S&F in repairwash basin brass CP mixer 15mm bore for mixing hot & cold water screwed down for iron pipe and fixed complate all as specified. 67 S&F in repairs 15mm dia bib tap fancy type(Long Nose) ISI Marked, cast copper alloychromium plated with crutch or butter fly handle screwed down screwed for Iron Pipe or brass ferrule and fixed complete all as specified and dirceted. 68 S&F in reoair Stop valve/ cock,/ angle valve Fancy TypeISI Marked, cast copper alloy, screwed down, high pressure with handle, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, fixed in repairs, complete all as specified. 69 S&Fin RepairPVC connections 15 mm size with PTMT nuts of length 600 mm, fixed in repairs, complete all as specified and diected by Engr-in-charge. 70 S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified. 71 S&F Sheet glass coner shelf of size 225x225 mm chrome plating everlasting shine/easy to clean/resisting strainassembly consisting of 5.5mm thick sheet glasswith chromium plated bracket guard and railingcomplete all as specified. Make : Cera Cat No : F5005102 or equivalent in approved makes 72 Cutting into existing manholes any size or any type for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required complete all as specified and directed by Engr-in-Charge. 73 M&L RCC Work 1:2:4 Type B-1 Slab supported on walls beams and columns infloors, roofs, landing, balconies canopies, deck slabs and in shelves and the like complete all as specified. 74 Formwork to rough finshedsurface sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. 75 M&L for Steel reinforcement 10mm dia and over, TMT bars, cut to length, bent to shape required including, cranking, bending, spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips,complete all as specified and directed . 76 M&L for steel reinforcement 6 to 8mm dia and over, TMT bars, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed . 77 S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanksor sape of any type of manhole cover and similar work conforming to Fe.290.Gde-E-165 78 Rolled sections Fe 410-W (Gde-E-250 qualityA) as in main and cross beams, columns hip and jack rafters; purlins where connected to common rafters and running rails, and guides for sliding doors; fixed with angle cleats or other connecting plate including spacial shaped with ,drilled/wellded for fixing complete all as specified 79 S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleatsincluding spacial shaped etc Height Up to 6 Mtr. confirming to Fe-410W(Gde-E-250 qualityA)with gusset plates rail braces etc ,drilled/wellded for fixing of steel sheeting or other covering and hanging fixing complete allas specified. 80 S&FPre painted aluminium zinc corrugated steel sheet(galvalume base) of thickness 0.50mm in colour and profile having tensile strength of 550Mpa as approved by Garrison Engineerand to be factory moulded and fixed with hot dipped galvanised with high durable protective triple coated self tapping screws/self drilling screws, to suit the roofing in customized colour matching with the colour of roof covering/cladding to wall and screws are to be fixed using Torque adjustable electronic gun screws driller of suitable capacity all as specified 81 M&L 100 mm thick, Plain cement concrete 1:2:4 type B-2 using 40mm graded crushed stone aggregates as in sub base for laying floor finishes including finishing the surfaces even and rough without using extra cement, complete all as specified and as directed by Engr-in-Charge. 82 M&L 20 mm thick screed bed or bedding layer in CM 1:6 finished fair and even for laying floor finishes/tiles etc complete all as specified and directed by Engineer-in-Charge. 83 M&L for Vitrified Ceramic coloured tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, inFloor surfaces etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified. 84 M/L 75mm thick, Cement concrete 1:3:6 type C2 using 40mm graded stone crushed aggregate in plinth protection, finished even and smooth using extra cement, including making joints 12mm wide to the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen and sand 1:3 by weight complete. 85 M&L for 12 mm thick PVC laminated Gypsum ceiling board / tiles , 595 x 595 mm in size, fixed in ceiling with screws toframe work with Aluminium grit frame work or GI channel powder coated at bottom , frame work complete all as per manufacturer instruction & complete all as specified and as directed. 86 S&F for Hangers 6 mm dia GI ( up to 1200 mm length ) adjusting level fixed to roof slabs by means of ceiling cleatsmade out of GI flat 40 X 3 mm size 60 mm long drawing complete all as specified and as directed. 87 Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to entre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel complete all as specified. 88 S&F in repair 5mm thick looking mirror of selected quality with and including stainless steel spacers with bevelled edging any size .complete all as spd and direcetd by Engg-in-charge. Note :Looking mirror shall befixing on wall with proper manner as per manufacturer instruction without any extra charge . 89 S&F for 5mm thick sheet plantex louvers panel for wall/PVC wall panel/3d wall panel for interior wall /Eco-friendly fluted panel 300x3000 mm length with all solvent and fixing as per manufacturer instruction specified in drawing and directed by Engr-In-Charge.Note: The Sample wiil be produce to GE for approval before this the work will be execute. User approval is mandatory for color and design, there will be no extra Charge in this regard. 90 Removing of excavated material (soil)from distance exc 1.5Km and n exc 5.Km from excavated soil lacation as directed by Engr-in-Charge (i.eOut side AF Stn) or where low laying area complete all as specified and directed by Engr-in-Charge. 91 Preparation of newly plastered surfacestwo Coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturers specification over acomplete all as specified and directed by Engr-in-charge. 92 Preparation of newly plastered surfacestwo Coats overFinishing walls with Acrylic Smooth exterior paint of required shade(Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specifiedand directed by Engg-in Charge. 93 Point wiring for one lightpoint/ fan point controlled by one switch with 1.5 sqmm FRLS PVC insulated unsheathed copper condector single core multi strand flexible cable and 1.5 Sqmm flrs PVC insulated unsheathed copper conductor single core cable (green colour) as earth lead in and including concealed non metallic rigid PVC conduitmedium grade withall fittings ( ISI marked ) controlled by one switch including CI/MS sunk box required size & as directed by Engr-in-Charge & 3 mm thick plastic laminated sheet, including cutting chases to wall and making good the disturbed surfaces to match with the existing specification complete all as specified and directed. 94 (a)One light point controlled by one switch. 95 (b)One wall fan/Exhaust fan/ceiling fan point controlled by one switch. 96 (c)One 3 pin socket outlet point 5 Amps on independent, 97 (d)One 3 pin socket outlet point 15 Amps on independent, with cables 2.5 sq. mm size . 98 Supply and fixing for energy saving environmental friendly, Cobb lights 12 watt,Colour Cool Day Light,Material Aluminium Style 12W Light fixture form Recessed Product Dimensions 10.5L x 10.5W x 5.2H Centimeters Include: 1 Recessed COB Spot Light Wattage: 12 watts Warranty: 2 Year on Product Long Life - 35,000 Burning Hours Robust Construction – Die-cast Aluminium Extra Bright Light - 95Lumen/Watt Strong focused adjustable beam at 36 Degree No Visible Flicker Cutout Size - 95MM complete with all accessories pre-wired twin core twisted flexible copper conductor cable with suitable size with ceiling rosecomplete all as specified and directed. 99 S & F Socket outlet flush universal modular (piano) type 6 pin 16 Ampswith suitable plate and cover complete all as specified and directed. 100 S & F Socket outlet flush modular (piano) type 5 pin 6 Ampswith suitable plate and cover complete all as specified and directed. 101 S & F Switch Modular (piano) flush button single pole one way 16 ampswith suitable plate and cover complete all as specified and directed. 102 S & F Switch Modular (piano) flush button single pole one way 6 amps 1 module with suitable plate and cover complete all as specified and directed. 103 S & F MCB double door Distribution board,Single pole & neutral 240 Volt,8 way,type With 200 Amps bus bar complete all as specified and directed. 104 Supply and fixing amp rating 240V, 10KA C curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. 105 (a)SP 5 To 40 AMP 106 (b)SPN 40 to 63 AMP 107 Supply and fixingDistribution board iron clad vertical type TPN DB, double door with IP-43 1K-09 protection suitablefor MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 6 way, complete with appropriate size copper bus bar including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site including all existing connectionto electric meter incl taking out old unserviceable board/panel type complete all as specified directed by Engr-in-Charge.Make- Legrand/Havells/L&T/Indoasian(Note: MCBs and MCCB will be measured and paid seperately under relevent items) 108 M & L for MCCB TPN 125 Amps ,415 Volts complete. Make- Legrand/Havells/L&T/Indio asian 109 S&FPVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sq. mm 3.5 core complete all as specified & directed 110 Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in any type ofsoil for laying of LT UG cablescomplete. Note:- The Ratequoted deemed to including cutting and removal of PSP Sheets wherever occured during excavation and the same shall be staged at desired location as directed at site. 111 Returning, filling in,including spreading levelling, watering and well ramming in layers not exceeding 25 cm thickin any type of soil. 112 Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point 113 Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed by Engr-in-Charge. NOTE Only punned thickness shall be measured for payment purpose. 114 Sub class B old size bricks well burnt as covering to under ground cables , laid dry, flat over the cables on sand cushioning with width equal to length of the brick as mechanical protection to cable, complete all as specified and directed. 115 Supply and fixing Electric design ceiling fans Colour As per site requirementCeiling FanStyle Stealth Air BLDC Product Dimensions 30D x 54.5W x 19.5H Centimeters Aerodynamic blades for more Air delivery at lesser noise;Timer setting for 1/2/3/4 hour; Five star ECO BLDC technology motor for less power consumption;In built voltage stabilization to give constant performance at lower voltages RF type Remote control operation for all direction sensingas specified, complete all as specified and directed by Engr-in-charge. 116 S & F Ceiling Fan step regulator, 120W modular type complete all as specified and directed. 117 S & F ceiling rose surface bakelite 2 to 3 terminals 65 x 50mm complete all as specified and as directed by Engineer-in-Charge. 118 Supply and install hi wall split AC of capacity 1.5 TR units indoor/outdoor complete with cordless remote control unit and with in built air ionsier and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity as specified.. 119 Supply and fixing sheet Metal enclosure distrbution box single pole and neutral with two pin and earth plug and socket complte with one single pole MCB 20 Amp 240 voltof suitable size all as per directed. 120 Automaticvoltage stabilizer , single phase, copper wound, with volt meter with electronicrelays suitable for correction on single phase , designed for input variation between 90 V to 250 V with output voltage stabilized at 230 V with accuracy ± 2.5% of capacity 5 KVAincluding making electrical connections with flexiable copper wire 3 core complete, all as specified. 121 M&L for sub main wiring with two run of single corePVC insulated FRLS copper cable multi-stranded conductor 4 Sqmm drawn through in and including Non metalic PVC heavy duty conduit / PVC casing capingof suitable size as required at site with all accessories with 2.5 Sqmm PVC insulated unsheathed copper conductor as earth wire, connected to common earth complete all as specified and directed. 122 M&L for sub main wiring with two run of single corePVC insulated FRLS copper cable multi-stranded conductor 6 Sqmm drawn through in and including Non metalic PVC heavy duty conduit / PVC casing capingof suitable size as required at site with all accessories with 4.00 Sqmm PVC insulated unsheathed copper conductor as earth wire, connected to common earth complete all as specified and directed. 123 Cutting Chaser for conduit and sinking boxes and making good to walls,floor etc. 124 NOTE:- SCHEDULE A PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch A Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder.