Tender For Repair And Maintenance Of Internal Electrification Of Zone C, D And E And Allied Location Of Est No 22 Area Of Age (I) Chakrata Under Hq Cwe Dehradun; 1 Taking down carefully existing aluminum/copper surface/concealed point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, lamp holder, regulators, sockets, wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and making good the disturbed surfaces in CM 1:3 of walls, floors, ceiling etc including painting if required to match up with existing surfaces complete all as specified and directed. Note: old point wiring obtained from Sl item no 2.00 to 2.07 and 3.00 to 3.07 of Sch A. 2 M & L point wiring with 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade, FRLS-H grade in and including medium dutyconcealed / surface steel conduit 20 mm dia or higher and conduit fittings and all accessories with suitable size of Metal flush box zinc oxide plated or PVC non metallic surface mounting type box,as per site requirement, with modular plate and frame of 01 module to 18 module as required at site, for mounting of modular switches, sockets etc including conteneous earth wire PVC insulated, unsheathed, multi stranded copper conductor cable 1.5 sqmm (nominal area) FRLS-H grade, green colour, up to common earth and connected to earth dolly compete all as specified and directed of the following.Note :- (a) Point wiring should be carried out on surface mounted rigid PVC conduit at the places, whereRCC beam, column, truss, roof or false ceiling exists and as per direction.(b)Colour code will be maintained as per IE rule i.e. Red/Yellow/Blue for phases, Black for Neutral and Green for earth wire. (c) Cost of Modular Metal flush box, modular plate and frame deemed to be included in quoted rate for point wiring and the of flush metal box will be decided by the Engr-In-Charge.(d) Make of Modular metal flush box or PVC non metallic surface mounting type box modular plate and frame, switch, socket, regulator, bell push should be same & colour of frame switches match up with the surrounding. (e) Switch, socket, regulator, bell push will be measured and paid seperately under respective item,(a) One light point controlled by one 1-way modular switch. 3 Ditto all as peritem No 2 above but for One bell controlled by one 1-way switch. 4 Ditto all as peritem No 2 above but for One Exhaust fan point controlled by one 1-way switch. 5 Ditto all as peritem No 2 above but for One three pin 5 Amp socket on same board. 6 Ditto all as peritem No 2 above but for One three pin 5 Amp socket on independent board 7 All as per item No 2 above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity coductor of size 2.5 Sq mm. 8 All as per item above but one 3 pin socket outlet 15 Amp independent, with cable 4.0 Sq mm size, with earth continuity coductor of size 4.0 Sq mm. 9 M & L point wiring with 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade, FRLS-H grade in and including medium duty concealed / surface PVC conduit 20 mm dia or higher and conduit fittings and all accessories with suitable size of Metal flush box zinc oxide plated or PVC non metallic surface mounting type box,as per site requirement, with modular plate and frame of 01 module to 18 module as required at site, for mounting of modular switches, sockets etc including conteneous earth wire PVC insulated, unsheathed, multi stranded copper conductor cable 1.5 sqmm (nominal area) FRLS-H grade, green colour, up to common earth and connected to earth dolly compete all as specified and directed of the following.Note :-(a) Point wiring should be carried out on surface mounted rigid PVC conduit at the places, whereRCC beam, column, truss, roof or false ceiling exists and as per direction.(b)Colour code will be maintained as per IE rule i.e. Red/Yellow/Blue for phases, Black for Neutral and Green for earth wire. (c) Cost of Modular Metal flush box, modular plate and frame deemed to be included in quoted rate for point wiring and the of flush metal box will be decided by the Engr-In-Charge.(d) Make of Modular metal flush box or PVC non metallic surface mounting type box modular plate and frame, switch, socket, regulator, bell push should be same & colour of frame switches match up with the surrounding. (e) Switch, socket, regulator, bell push will be measured and paid separately under respective item, One light point controlled by one 1-way modular switch. 10 Ditto all as peritem No 3 above but for one bell controlled by one 1-way switch. 11 Ditto all as peritem No 3 above but for One Exhaust fan point controlled by one 1-way switch. 12 Ditto all as peritem No 3 above but for One three pin 5 Amp socket on same board. 13 Ditto all as peritem No 3 above but for One three pin 5 Amp socket on independent board 14 All as per item above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity coductor of size 2.5 Sq mm.One three pin socket outlet 15 Amp independent board,with cable 2.5 Sq mm size, with earth con 15 All as per item No 3.00 above but one 3 pin socket outlet 15 Amp independent, with cable 4.0 Sq mm size, with earth continuity coductor of size 4.0 Sq mm. 16 M & L in replacement for circuit/submain wiring alongwith earth wire and PVC conduit on wall surface or concealed with the following sizes of FRLS-H, PVC insulated unsheathed, 1100 Volts grade, single core copper conductor cable, drawing in and including new med, grade, suitable size PVC conduit required saddle / hook fastener/ screws etc to fix on wall / chases as directed as required. Rate shall be including for taking down old submain wiring and making good disturbed surfaces of walls/floors etc complete all as specified and directed:- (Note: Colour code shall be maintained as per IE rule)(a)2 x 2.5 sq.mm + 1 x 2.5 sq. mm earth wire 17 (b) 2 x 4.0 sq.mm + 1 x 4.0 sq. mm earth wire 18 (c) 2 x 6.0 sq.mm + 1 x 6.0 sq. mm earth wire 19 S & F Modular switch 1 way 10 A 1 module. 20 S & F Modular switch 1 way 10 A 1 module. Note : Modular - switch socket with complete. 21 S & F Modular switch 1 way 16 A 1 module 22 S & F Modular socket 6 A- 2/3 pin combined 2 module, 23 S & F Modular socket 6/16 A- 2/3 pin combined 2 module, 24 S & F Ding dong bell AC 230 V single pole 25 S & F Buzzer bell AC 230 V single pole, 26 S & F Ceiling rose, 3 terminal/PVC/polycarbonate, isolated body 230 V AC. 27 S & F Switch socket combination 2 in 1, 6 A flush type 28 S & F Switch socket combination multipurpouse 2 in 1 , 3 pin 6 /16 A flash type universal, 29 S& F in repairs MCB SP 6 to 32 Amps, 240V, 10KA, ISI/IEC 60898-1 2002, Compatible with singnal and control Auxiliaries complete all as specified & directed . 30 S& F in repairs MCB SPN 32 Amps, 240V, 10KA, B Curve. 31 S& F in repairs MCB SPN 40 to 63 Amps, 240V, 10KA, B Curve. 32 S& F in repairs MCB TPN / FP 32 A, 415 V, B Curve. 33 S& F in repairs MCB TPN / FP63A, 415 V,B Curve. 34 S & F in replacement sheet metal enclosure powder coated,as per IEC 61439-3, With IK 09 & IP43, Depth Up to 71mm with Door earthing System, Door reversable provisions DB complete all as specified & directed for the follwing size :- DB SPN 4 way, 240V with 100 amps rated bus bar 35 DB SPN 8 way, 240V with 200 amps rated bus bar 36 DB SPN 12 way, 240V with 200 amps rated bus bar 37 DB TPN ,4 way, single door, 415 V suitable for incomer and outgoing MCB TPN complete. 38 S & F in replacement TPN DB4 way vertical type, suitable for and incomer MCCB TP/4P, 100A, 16 KA and outgoing MCBs SP/TP including incoming bus bar 200Amp, neutral links, blanking plates,as per IEC 61439-3, With IP 43 - #IK 09 with double door etc, complete all as specified and directed . (Note :- MCCB and MCBs will be measured and paid under respective item) 39 S & F MCCB 100 Amp FP,16 KA,with ICS=100% ICU, adjustablethermal-0.8-1IN, adjustable magnetic-5 to 10IN, With Option for in Built or Add on Module for ELM complete all as specified and directed . 40 S & F sheet metal enclosure with socket plug top and MCBs single pole and neutral with a two pin and earth plug and socket complete with single pole neutral MCB of 20A, 240V, complete all as specified and directed . 41 Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and as directed. 42 Supply and fix exhaust fan, steel body AC single Phase. 230V of size size 450 mm sweep heavy duty sweep with, blades, and frame and louvers complete all as specified and as directed. 43 Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250/200 mm complete all as specified and as directed. 44 S & F of geyser 25 Ltr capacity from any position after disconnecting the inlet and outlet connection, depositing to MES store and Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece, 304 grade braided stainless steel connection pipe for HOT and COLD water and can be fixed in same or new location complete all as specified and as directed. 45 S & F LED lights fitting 1x20W, 220V, AC box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. 46 S & FSupply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lampincluding connecting up with three core flexible copper conductor cable of suitable size complete complete all as specified and as directed. 47 Supply and fixing round / squareshape 12 watt 220 volts AC recessed/surface type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. 48 S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. 49 Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed. 50 Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed. 51 Supply and fixing of Switch flame proof rotary type with termination box in LM6, 16A, single pole 250Vcompete all as specified and directed of the followingcompete all as specified and directed of the following complete all as specified and as directed. 52 Supply and fixing LED Building Security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. 53 M & L for earthing complete with GI or steel earth plate electrode 60cm x 60cm x 6mmconnected to galvanized iron strip wire 4 mm dia as earthing by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-Iand specified includingprovision of earth wire protected by 40mm dia medium grade GI pipe and watering pipe shall be 20mm bore medium grade GI pipe, and including all excavation andearth work & connecting the earthing to an earthing test point /transformer nuetral/body/ Lt panel etc and testing on completion, complete all as specified & directed. 54 S & F gang box PVC for 5 Amps switch and socket complete all as specified and as directed. 55 S & F gang box PVC for 15 Amps switch and socket complete all as specified and as directed. 56 Supply and fix in replacement on-load changeover switch 415 V, 4 pole, 63 A complete all as specified and as directed. 57 Supply and fix in replacement on-load changeover switch 415 V, 4 pole, 32A complete all as specified and as directed. 58 S & F Copper cable cord flexible 3 core PVC insulated and overall PVC sheathed of size 2.5 SQ MM fixed in repair for making connection of Gyesers as directed. 59 S & F 450 mm long 304 grade braided stenless steel connection suitable for hot & cold water supply with cromium plated brass screwed nuts at both ends with washers fixed in repairs for making water connection for geyser, 60 S & F in replacement Heating element for geyser 1500/2000 wattsScrew type /Clamp Type complete all as specified and as directed. 61 M & L for rewinding of exhaust fan of any make/model and 250mm sweep including removal of existing burnt winding carefully from slots, cleaning the slots throughly with suitable cleaning agent, applying slot insulation and rewinding with enamelled copper conductor of same gauge/same number of turns as that of existing and connecting the coil suitable to operate on 230 V, single phase, AC supply, permanent capacitor type, tapping the winding and applying air drying the winding throughly and all as specified and directed ,including taking down exhaust fan. 62 M & L for rewinding of exhaust fan of any make/model and 450mm sweep including removal of existing burnt winding carefully from slots, cleaning the slots throughly with suitable cleaning agent, applying slot insulation and rewinding with enamelled copper conductor of same gauge/same number of turns as that of existing and connecting the coil suitable to operate on 230 V, single phase, AC supply, permanent capacitor type, tapping the winding and applying air drying the winding throughly and all as specified and directed, ,including taking down exhaust fan. 63 S & F Plug top 5 Amps 3 pincomplete all as specified and as directed. 64 S & F Plug top 15 Amps 3 pincomplete all as specified and as directed. 65 S & F LED Driver 3 Wcomplete all as specified and as directed. 66 S & F LED Driver 12 Wcomplete all as specified and as directed. 67 S & F LED Driver 24 Wcomplete all as specified and as directed. 68 S & F LED light Driver 35 Wcomplete all as specified and as directed. 69 S & F Wall Heater Avion 1000/2000 watts Manual Operation Auto Resume Function complete all as specified and as directed.