Tender For Provision Of Offers And Jcos Accommodation At Kiari Mil Stn Under Ge 860 Ews; 1 NOTE: Schedule ‘A’ Part - ItoPart -Xare Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. 2 Total amount of Sch A Part - I(BUILDING Works) 3 Total amount of Sch A Part - II (SITE CLEARANCE WORKS) 4 Total amount of Sch ‘A’ Part - III (INTERNAL WATER SUPPLY) 5 Total amount of Sch ‘A’ Part - IV (INTERNAL ELECTRIC SUPPLY)) 6 Total amount of Sch ‘A’ Part - V (PROTECTIVEWORKS) 7 Total amount of Sch ‘A’ Part - VI (HARDSTANDING WORKS) 8 Total amount of Sch ‘A’ Part - VII (SEWAGE DISPOSAL) 9 Total amount of Sch A Part - VIII(EXTERNALELECTRIC SUPPLY WORKS) 10 Total amount of Sch ‘A’ Part -IX ( EXTRNAL WATER SUPPLY WORKS) 11 Total amount of Sch ‘A’ Part - X (HOT WATER SUPPLY) 12 SCH A PART - XI(Miscellaneous B/R and E/M works for Sch A Part-II to Part-X)Note: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 5 signifies this fact only 13 Supply and fixing ofLED building security light, pressure die cast aluminum housing, 20/25 watts capacity, 240V, IP 65 class, with suitable in-built electronic driver complete incld. fixed on a bracket made out of 1.5 mtr long Med grade GI pipe 40 mm dia bend to shape as directed fitted on wall at a height not less than 5 mtr from groundwith MS clamp, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose/junction box with 1.5 sqmm PVC insulated 3 core wire complete all as directed and specified by Engr-in-Charge. NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. 14 Supply and fixing of Double door three phase prewired distribution board vertical DB VTPN 4 way with acrylic door made out of CRCA sheets 1.6 mm thick,phosphatised powder coated with copper Bus Bar 200 Amps, 415 V,IP 43/IK09, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and includingMCCB4 pole 63 Amp rating repturing capacity 16 KA (Note:- Single Phase MCBs are to be measured and paid for seperately) 15 Supply and fixing of LED Garden Light 9 W 220 V,single phase,IP-65 with post top fitting,powder coated aluminium die cast and spun aluminium with clear/opal diffuser suitable for landscape lighting complete all as specified and as directed by the Engineer-in-Charge. 16 RCC Septic tank for 25 users conventional designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.2 meter and overall depth of 1.95 meter complete all as specified and shown on drawing (Ref Drg No CELZ/D/ST-3009, Sh No 1/4 to 4/4 17 Soakage wells of size 3M dia x 4.5 M effective depth excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats complete all as specified and directed. 18 Supply, installation, connecting, testingand commissioning of cubicle compartmentalised outdoortype LT Panel size 1.8m x 1.5m x 0.7m, factory made, front and rear opening with locking arrangement, dust and vermin proof, CPRI approved, fabricated out of 3.15 mm thick CRCA sheet with canopy and base frame & mild steel angle iron stand, over all finished with epoxy powder coating, suitable for operation on 415 Volts, 50 Hz, AC supply, including earthing stud, labeling, etc. and section pillar box shall comprising the following complete including fixed in position with PCC foundation 1:4:8 Plateform, connected with electric supply complete all as specified and directed by Engr -in-Charge 19 (a)Bus bar chamber having 4 Aluminium strip Bus bar having air insulated and PVC sheathed 200 A Capacity fixed in position with required nuts bolts and porceline insulator etc.(b)MCCB 4 Pole, 16 KA, 415 V, with adjusstable Thermal and fixed Magnetic (Manual Fixed type) of capacity 125 Amps. ( Incoming )(c)MCCB 3 Pole, 16 KA, 415 V, with adjusstable Thermal and fixed Magnetic (Manual Fixed type) of capacity 63 Amps x 4 nos. (02 x Nos Outgoing and one feede pillar,01 spare)(d) ON Load Change over Switch 125 Amps 4 Pole adjustable type -01 No(e)Volt meter 0-500 Volt meter digital type with selector switch.(f) Amp meter 0-200 Amp digital type with suitable CT and PT with selector Switch. (g)Phase indicator lamp LED Type -1 setNote : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC platform including necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge. 20 Supply, install, connecting, testingand commissioning of cubicle compartmentalised outdoortype LT feeder pillar box size 0.6m x 0.45m x 0.3m, factory made, front and rear opening with locking arrangement, dust and vermin proof, CPRI approved, fabricated out of 3.15 mm thick CRCA sheet with canopy and base frame & mild steel angle iron stand, over all finished with epoxy powder coating, suitable for operation on 415 Volts, 50 Hz, AC supply, including earthing stud, labeling, etc. and section pillar box shall comprising the following complete including fixed in position with PCC foundation 1:4:8 Platform, connect with electric supply complete all as specified and directed by Engr -in-Charge 21 (a)Bus bar chamber having 4 Aluminium strip Bus bar having air insulated and PVC sheathed 100 A Capacity fixed in position with required nuts bolts and porceline insulator etc.(b) MCB TPN 40 Amp, 16 KA, 415 V). ( Incoming )-01 No(c) MCB TPN 40 Amp, 16 KA, 415 V). ( Outgoing )-01 No(d) MCB SPN 25 Amp(Outgoing)-01 No(e)Phase indicator lamp LED Type -1 setNote : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC platform including necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge. 22 Supply, installation, testing & commissioning of Outdoor (IP54) 11kV 630Amps 21KA/3 sec. Non- Extensible 3 Way Ring Main Unit Compact switchgear consisting of1 nos. fixed manual Vacuum Circuit Breaker Moduleand 2 nos. fixed manual Load break switch module and Copper Busbar in SF6 insulated stainless steel enclosure (2.5 mm thick, SS304 grade). The complete RMU must be type tested for Internal arc 21KA for 1 sec with AFLR Classification for Gas tank & Cable Chamber. The offered RMU must be suitable for working at an altitude of 3700 meter & temparature upto -25 Degree Centegrade. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. The Vaccum Interrupter must RMU manufacturers own make. Make of RMU shall be limited to : ABB/ SIEMENS/ SCHNEIDER INFRASTRUCTURE [ Channel partner / System Integrator / Authourized Partner/ License partner make RMU shall not be accepted. The complete RMU shall be consisting of followings: 23 (a) Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint) for each VCB Module.(b) Capacitive voltage indication fixed type system with LED for all the module(c) SF6 Gas pressure indicator on the gas tank.(d) Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO .(e) CT shall be minimum 80-40/1A ,2.5VA , 5P20 - 3 nos. for protection(f) Touch proof cable termination kit to be provided in each module 24 Supply, install, connecting, testingand commissioning of cubicle compartmentalised outdoortype LT Panel size 1.8m x 1.5m x 0.7m, factory made, front and rear opening with locking arrangement, dust and vermin proof, fabricated out of 3.15 mm thick CRCA sheet with canopy and base frame & mild steel angle iron stand, over all finished with powder coating, suitable for operation on 415 Volts, 50 Hz, AC supply, including earthing stud, labeling, etc. and section pillar box shall comprising the following complete including fixed in position with PCC foundation 1:4:8 Platform, connect with electric supply complete all as specified and directed by Engr -in-Charge 25 (a)Bus bar chamber having 4 Aluminium strip Bus bar having air insulated and PVC sheathed 600 A Capacity fixed in position with required nuts bolts and porceline insulator etc.(b)MCCB 4 Pole, 36 KA, 415 V, withmicroprocessor(Manual Fixed type) of capacity 400 Amps. ( Incoming )(c)MCCB 3 Pole, 16 KA, 415 V, with adjusstable Thermal and fixed Magnetic (Manual Fixed type) of capacity 100 Amps x 2 nos. (02 x Nos Outgoing)(d)MCCB 4 Pole, 125 A,16 KA, 415 V, with adjusstable Thermal and fixed Magnetic (Manual Fixed type) of capacity Outging for offr living accn )(e)Volt meter 0-500 Volt meter digital type with selector switch.(f) Amp meter 0-200 Amp digital type with suitable CT and PT with selector Switch. (g)Phase indicator lamp LED Type -1 setNote : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC platform including necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge. 26 Supply and fixing nitryle rubber insulation for tubing of size suitable for any pipe size & 32mm-50 mm thick outer dia, conductivity suitable for temperature range of (-)40ºC to (+)40ºC and class-0 fire resistance, water vapour permeability > 7000 and CFC free complete all as specified and directed. Note:-Area will be calculated based on outer dia. 27 Providing and fixing of aluminium cladding of 0.32 mm thick Aluminium Sheet on insulated pipes 32 mm dia (for exposed pipes only) but, 40 mm dia pipe (for exposed pipes only) complete all as specified and directed. 28 Material and Labour for providing tracer/antifreezing cable of range between 20 Watt/meter required to keep the pipe warm upto avoiding freezing of all as specified including electrical wiring cable for connection of suitable size complete all as specified and directed. 29 Supply and fixing Connection panel cum temperature controller to regulate electric supply to the Heat Tracer Cable 65W to maintain temparature to the water supply pipe line laid underground and to the exposed pipe line and connecting to the LT Supply complete all as specified and directed. 30 Supply and Fixing Submersible pump set suitable for 230 V , single phase system having capacity 1.0 HP.including making header complete all as specified and directed by Engineer-in-charge. ( 1 For stand by). 31 Supply and fixing submersible copper conductor cable 3 core, 2.5 sqmm 1100 volt flat industrial grade including nylon binding wire and accesories to clamp with column pipe at two places to each column pipe complete all as specified and directed. 32 Supply and fixing ofDOL starter 230 V single phase suitable for submersible pump set of capacity 1 HP all as specified and as directed by Engineer-In-Charge 33 Supply and fixing insulation tubing of size suitable for 20mm dia pipe and 13mm thick conductivity of nitrile rubber tubes class 0 with 0.32mm thick plain aluminium steel alloy 31000 H4 in ridges, hips, valley gutter drip and straight flashing of 28SWG thickness complete all as specified and directed. 34 Supply and fixing insulation tubing of size suitable for 25mm dia pipe and 13mm thick conductivity of nitrile rubber tubes class 0 with 0.32mm thick plain aluminium steel alloy 31000 H4 in ridges, hips, valley gutter drip and straight flashing of 28SWG complete all as specified and directed.