Tender For Addition/Alteration To Certain Married Accn At Air Force Station Pathankot Under Ge (Af) Pathankot.; 1 Schedule A Part-I (Building Works) 2 M&L for preparation of surface byscrapping and properly cleaning the surface to remove loose particles/existing vegetation/roots etc. with wire brushes and removing any type of existing roof treatment in any layer alongwith existing plaster so as to reach up to top of RCC roof slabcomplete in all respect , filling of cracks with Smart Care Hybried PU sealent wherever required for rendering or plastering work 10 mm thick in CM 1:3 on roof surfaces and finishing the surface without using extra cement for application of roof treatment(A) Apply first coat of fibre reinforced elastomeric liquid water proofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibres with sun reflectivity index (SRI) of 100-110, having minimum elongation of 350%, tensile strength 2.9 MPa and shall have crack bridging ability upto 2.5mm and shall resist 10 bars of hydrostatic pressure , reduce surface temperature upto 10 degree celsius with 33% dilution as primming coat. (b) Laying of fibre mesh of 0.3mm thickness weave in leno pattern having weight 45 gm/Sqm and pasting it properly with overlap of 50mm and allow it to dry. (c) Apply second undiluted coat @ 0.450 ltr/Sqm(d) Apply third and final coat undiluted @ 0.450Ltr/Sqm in color combination/ cameoflauging patternas directed by Engr-in-charge. Note : Application of water proofing treatment will be done Authorised applicator only/ or in presence of authorised rep. Certificate in this regard shall be submitted to Engr-in-charge. Shifting/removal of any wire/ cable/AC unit/water tank or any other object as per the site requirement and refixing of the same if needed is deemed to be included in rates quoted by contractor. 3 S&F in repair 150mm dia PVC (SWR) pipes single socketed in any lengthfixed to wall including clamps, bends, sockets, as required complete all as specified and directed by Engr-in-Charge. 4 S&F for rotational triple layer moulded polyethene water storage tanks of capacity 500 litres, (cylindrical vertical with closed top) hoisted and fixed in position including necessary GI fittings, inlet/outlet washout, overflow pieces long nipples, checknuts & washer ,brass valve 20mm high pressure with polythene float and fly nutetc complete including dismantling existing RCC/Iron/PVC water tank all as specified and directed. 5 S&F for rotational triple layer moulded polyethiene water storage tanks of capacity 1000 litres, (cylindrical vertical with closed top) hoisted and fixed in position including necessary GI fittings, inlet/outlet washout, overflow pieces long nipples, checknuts & washer ,brass valve 20mm high pressure with polythene float and fly nutetc complete including dismantling existing RCC/Iron/PVC water tank all as specified and directed by Engr-in-Charge. 6 S&F for 20mm bore Steel water tubing medium grade, galvanised with all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed by Engr-in-Charge. 7 Demolition of brick work , built in cement mortar or cement lime mortar including all quions, arches, pillars, etc including demolition of precast RCC articles and disposal of debris out of MoD land complete all as specified and directed by Engr-in-Charge. 8 M&L brick work with sub class B burnt bricks straight or curved on plan 6m mean radius built in cm 1:6complete all as specified and directed by Engr-in-Charge. 9 Material and labour for high depth cladding coloured glazed ceramic tiles rustic-matt type in vertical surface such as gate piller, dado, etc 450mmX 300mmX 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of the tiles over and including 10mm thick rough cement plaster to receive tiles in CM 1:4 complete aall as specified and directed by Engr-in-Charge.Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by Engr-In-Charge and Rates also including in this item for necessary raking circular cutting or notching and waste on tiles. 10 Demolition of Roofs, floors (other than ground floors), beams,staircases,landings, chajjas,RCC Water tank similar suspended work cement concrete is reinforced (reinforcement cut as required to facilitate demolition) and disposal of debris out of MoD land complete all as specified and directed by Engr-in-Charge.Note:- Demolition will be done only by mechanical cutter only . 11 M&L for RCC Slabs supported on walls, beams and columns in floors,roofs, landings, balconies,canopies, deck slabs Design MixM-25 (20 mm graded aggregate) set in CM 1:6, as in slabs for Water tank base size as required etc with plain fair faces incl necessary formwork complete all as specified and directed by Engr-in-Charge. 12 M<MT bars 10 mm dia and over, cut to length, bent to shape required, including cranking,bending spirally for hooping for slab, hooking ends and binding with and including mild steel wire (annealed)not less than 0.9mm dia complete all as specified and directed by Engr-in-Charge. 13 Dismantling structural steel work including doors, gatesetc.complete all as specified and directed by Engr-in-Charge. 14 S&F for stainless steel (Grade 304) Gates, grills made of hollow tubes, channels, plates, Sheet etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the gate with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, and fixing to RCC Columns or Brick work complete all as specified and directed by Engr-in-Charge. 15 S&F for high pressed laminate (HPL) Sheets of 10 mm thick having top layer is a decorative layer, and the entire sheet is coated with a clear protective layer to be fitted on gates, texture, Shade & Colour complete aall as specified and directed by Engr-in-Charge. 16 Taking down cement plaster of any description and thickness on walls etc including racking out joints, hacking for key, scrubbing down with water etcincluding necessary scaffolding up to four storeys height of bldgs if required and removing of debris out of MoD land complete aall as specified and directed by Engr-in-Charge. 17 Material and labour for rendering 15mm thick in CM 1:4 mixed with liquid water proofing compound (as per manufacturer’s instructions) on fair faces of brick work ,concrete surface of wall, fin, facia, chajjas, parapet and similar article finished surface even and smooth without using extra cementincluding necessary scaffolding up to four storeys height of bldgs if required complete aall as specified and directed by Engr-in-Charge.Note:- WPC shall be measured and paid separately 18 M&L for preparation of surfaces of high quality grade exterior wall putty 2mm thick making the surface smooth complete aall as specified and directed by Engr-in-Charge. 19 M&L for preparation of new surface of wall and applying two or more coats of weather proof acrylic exterior emulsion paint (up to four storeys height of bldgs) as approved of any shade/colourover a coat of primer as per manufacture instruction using auto paint roller & making good surface including necessary scaffolding up to four storeys height of bldgs if required complete all as specified and directed by Engr-in-Charge. 20 Supply only `Liquid Water Proofing Compound. complete all as specified and as directed. 21 Material and labour for rendering dubbing coat over damaged irregular of patches at colmn,chajjas, canopy and soffit, roof projection ceiling faccia etc using GI Chicken Mess of size0.25 mm thick aparture fixed with nails incl necessary scaffolding arrangement (up to 3rd floor of bldg) at required at site average 15mm thick in cm 1:4 over cement slurry at coat thick @ 3 kg/Sqm making the surface even followed by 5mm thick rendering with cement sand mortar1 : 3 finished even and smooth incl applying two coat of weather proof emultion paint incl making of drip course as reqd complete incl roughening surface of old concrete by sweeping clean and washing with water all complete all as specified and as directed by Engr-In-Charge. Note :-Rate for form work if reqd in the rate quoted by the contractor. 22 Demolition of cement concrete or lime concrete (unreinforced) in ground floors and Pavings not exc 15 cm thick (below or above ground level ) and removing the debris outside from defence land complete all as specified and directed by Engr-in-Charge. 23 M&L for cement concrete type C-1 1:3:6 (using 20mm graded crushed stone aggregate) as in plinth protection and paving 75mm thick laid in slope finished even and fair without using extra cement incl making joints every 2.5m and corner filled with bitumen 85/25 complete all as specified and directed by Engr-in-Charge. 24 M&L for cement concrete type D-2 1:4:8 (using 40mm graded crushed stone aggregate) as in floor and paving 75 mm thick laid in slope complete all as specified and directed by Engr-in-Charge. 25 M&L for cement concrete type B-1 1:2:4 (using 20mm graded crushed stone aggregate) as in floor and paving 40 mm thick laid in slope finished even and fair without using extra cement complete all as specified and directed by Engr-in-Charge. 26 M&L for non skid heavy duty designer coloured tiles as in floor for parking or other open area like flag post etc of 10 to 12 mm thick area of each tiles exc . 0.11 sqm and n.exc 0.18 sqm in floor etc of pattern approved by GE, set and jointed (joint free) in neat cement slurry and pointed in coloured cement over and incl screed bed or bedding layer of mortars 15mm thick in CM 1;6 laying floor finishes complete all as specified and directed by Engr-in-Charge. 27 Schedule A Part-II (E&M Works) 28 Point wiring for one light/ fan/bell point controlled by oneswitch using 1.5 Sq mm FRLS copper conductor cables (multistanded) PVC insulated and unseathed in Wiring with Copper conductor cables in PVC conduit of appropriate size, medium grade withsunken boxes & PVC back plate for mounting alltype switches, sockets & regulators etc with front plateincluding supplying and laying PVC insulated unsheathed 1100 volts coppper conductor cable 1.5 Sq mm as earth wire stranded and conected to earth dolly as specified incl cutting / cheasing as required at site..Note : Cutting and making samethe wall patchs after layingthe wire and conduit using putty, white wash and distamper. The surface should be made smooth using putty and should match exactly with the existing wall finish. 29 S&F piano switch5 Amps single pole one way230 V, 50 Hz, AC ,complete all as specified and directed by Engr-in-Charge. 30 M &L for Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block complete all as specified and directed by Engr-in-Charge. 31 S&F for sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 2x1.5 Sqmm in PVC concealed conduit/casing capping20mm dia including PVC insulated copper conductor cable1.5 Sq mm as earth leadincluding taking down old sub main wire complete all as specified and directed by Engr-in-Charge. 32 S&F for1100 Volts grade heavy duty cable with PVC insulated aluminium conductor standard served with an inner sheathing of PVC tape and over all PVC Sheathed 06 Sqmmx 2 coresize all as specified including taking down old cable complete all as specified and directed by Engr-in-Charge. Note : Earth work and other connected work shall be measured & paid sperately. 33 S&F for tubing lightgrade 40 mm bore galvanised iron with all fittings and fixed to poles, walls etc. with flat iron clamps/GI / bolts/nuts/washers or laid in floors/under roads complete including sealing material all as specified and directed of the following bores complete all as specified and directed by Engr-in-Charge. 34 S&Ffor gate lightdecorative post top for 360 degree indirect light with UP 65 protection. Resistant to impact and corrosion, glare free and better uniformaty incl making necessary arrangements all as required at site and complete all as specified and directed by Engr-in-Charge.. 35 Supply and fixing pressure die cast powder coated housing with PC diffuser, Efficient high output LED with IP 65 Protection incl making necessary arrangemenrs all as required at site complete all as specified and directed by Engr-in-Charge. 36 Supply and fixing for wall light for illuminiating the pictures of name plates of capacity upto 6 watt LED complete all as specified and directed by Engr-in-Charge. 37 M&L Earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level ) withtop edge of earth plate not less than 1.5 Mtr below normal ground level connected to earth lead wire 4 mm as earth lead by means of bolts, nuts washers and check nutsof steel/GI duly protected with 20 mm bore light grade pipe upto main board , 20mm bore watering pipe light gradewith CI/MS funnel and wire mesh including excavation, earth work in any type of soil and removing the surplus soil to a distance not exceeding 50 Mtr, add charcoaldust and common salt as diirectred by the Engr-in-charge all as shown in electrical plate No. 03 of SSR part-I 2009 having pit in PCC 1:2:4 type B-1 including angle iron frame made of angle iron of size 40x40x6mm grouted in PCC pit for CI cover of required size, funnel withwire mesh complete and all as specified and as directed by Engr-in-charge. 38 Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in any type of soil for laying of cable completeall as specified and directed by Engineer-in-charge. 39 Returning filling in (soil) including spreading levelling, watering and well ramming in layers not exc 25cm thick all as specified and directed by Engineer -in-charge. 40 Removal of excavated soil to a distance n.exc 50 m anddepositing where directed at a level not exc 1.5 mtr above the ground level/starting point complete all as specified and directed by Engr-in-Charge.. 41 Sand cushioningto the undergroundcables using new dry river sand laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete, punned to 18cm, complete all as specified and directed by Engineer-in-Charge. Note :Punned thickness of 18cms shall be measured for payment. 42 M&LSub ClassBbrickcovering protectionto the eletric cablelaiddry flat transversallyalongthe lengthof cableon sandcushioningwith widthequal to lengthof brickcomplete all as specified and directed by Engr-in-Charge. 43 M&L for PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in coping including necessary form work finishing the cement concrete surfaces even & smooth using extra cement complete all as specified and directed by Engr-in-Charge.