Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 08-11-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 15-11-2025 |
| Sl. No. | Item Description |
| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premisescomplete all as specified and as directed. |
| 2 | Demolition of cement concrete ,un-reinforced in ground floors and paving not exceeding 15 centimetre thickness, below or above ground level complete all as specified and as directed. |
| 3 | Dismantling water tanks of any description exc. 250 ltrs and not exc. 500 ltrs capacity and removing from site. |
| 4 | Dismantling water tanks of any description exc. 500 ltrs and not exc. 1000 ltrs capacity and removing from site. |
| 5 | S & F 500 liters rotational moulded polyethylene water storage tank, double layered (cylindrical vertical with closed top cover) as per IS-12701-1996, hoisted and fixed in position including necessary arrangements for fixing inlet, outlet and ball valve (float valve) complete as specified. |
| 6 | S & F 1000 liters rotational moulded polyethylene water storage tank, triple layered (cylindrical vertical with closed top cover) as per IS-12701-1996, hoisted and fixed in position including necessary arrangements for fixing inlet, outlet and ball valve (float valve) complete as specified. |
| 7 | S & F in repairs lid for polyethelene water storage tank exc 250 ltr and not exc 500 ltrs including fixing PTMT nuts/ binding wire complete all as specified and directed. |
| 8 | S & F in repairs lid for polyethelene water storage tank exc 500 ltr and not exc 1000 ltrs including fixing PTMT nuts/ binding wire complete all as specified and directed. |
| 9 | M&L for vitrified ceramic tiles 8-10mm thick (square/rectangular), polished, coloured (light shade as approved), area of each tile not exceeding 0.36 sqm, on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick screed bed in cement & sand mortar (1:4) complete all as specified & directed. |
| 10 | M&L for colourglazed ceramic coloured tiles 350mmx250mmx7mm/ 450x350x7 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement as in vertical surfaces such as skirting, dados and risers to steps etc to match with and including 10 mm thick screed bed or bedding layers in cement mortar (1:3)complete all as specified and directed. |
| 11 | M&L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular)area of eachtile exceeding 0.06 Sqm but notexceeding 0.11 Sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar (1:6), complete all as specified anddirected. |
| 12 | M&L for 1st quality Joint free Non-skid Ceramic tiles 7 mm to 8 mm thick (square/ rectangular) area of each tile exc.0.18 sqm but not exceeding 0.38 sqm,in floors etc. set and jointed in neat ement slurry and pointed in white or coloured cement to match over 15 mm screed bed in CM (1:6) all as specified & directed by Engineer in Charge. |
| 13 | M&L for colured Virified Ceramic tiles 8-10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed or bedding layer in cement mortar (1:4) complete all as specified and as directed. |
| 14 | M&L for 75 mm thick P.C.Ctype C-2, 1:3:6 using 40mm graded aggregate as in Sub-floor, sub base etc finishing the surfaces of concrete (without using extra cement) even and rough to receive the topping layer complete all as directed. |
| 15 | M&L for Coloured rubber moulded Chequred cement concrete tiles 300 x 300 x 25mm thick, set, jointed and pointed in grey cement mixed with pigments in floors, over 20mm screed bed in CM 1:6, complete all as specified and directed. |
| 16 | S&F20 mm thick granite slab cut bedded and jointed with grey cement slurry and pointed with white cement with admixture of pavement to match the shade of granite stone incl grinding and polishing overand including 20mm screed bed in CM (1:6) completed all as directed. |
| 17 | M&L for 20mm thick Granite (of any type) machine cut, in verticle surfaces bedded and jointed with grey cement slurry, over and including 12mm thickin cementmortar (1:3) and pointing with white cement (1:2)using marble dust, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete complete all as specified and directed by Engr-in-charge. |
| 18 | M&L for Rounding to edges of stone slabs one edge, such as in steps, cooking platform, basin platform and other similar situationscomplete all as directed by Engr-in-Charge. |
| 19 | M&L for 75 mm thick PCC (1:3:6) type C2 using 40 mm graded crushed stone aggregate as inplinth protection,surface finished fair and even,laid to slope of 1:30 in alternative bays not exceeding 3 meter in length, complete, all as specified and directed. |
| 20 | M&L ForForming Construction joint 30mm deep x10mm wide filled with Grade \"B\" sealing compound complete all as specified and directed. |
| 21 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc. of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using platevibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed. |
| 22 | S & F oval type counter basinsize 595x420x200 including waste coupling, waste pipe, connection pipe required length etc complete as specified and directed by Engr-in-Charge. |
| 23 | S&F in repairs 15 mm dia gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe. |
| 24 | S&F in repairs 20 mm dia gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe. |
| 25 | S&F in repairs 25 mm dia gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe. |
| 26 | Taking up or down steel tubing 15 mm bore and connections including cleaning for refixing or removing from site. |
| 27 | Taking up or down steel tubing 20 mm bore and connections including cleaning for refixing or removing from site. |
| 28 | Taking up or down steel tubing 25 mm bore and connections including cleaning for refixing or removing from site. |
| 29 | Supplying and laying of 16 mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 with all fittings and fixed complete on walls and ceilings or laid in floors all as specified and directed. |
| 30 | Supplying and laying of 20 mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 with all fittings and fixed complete on walls and ceilings or laid in floors all as specified and directed. |
| 31 | Supplying and laying of 25 mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 with all fittings and fixed complete on walls and ceilings or laid in floors all as specified and directed. |
| 32 | S&F of Brass Elbow 16/20 mm bore complete all as specified |
| 33 | S&F of Brass Elbow (3/4 X ½) 20 mm bore complete all as specified |
| 34 | S&F of Brass Tee 16/20 mm bore complete all as specified |
| 35 | S&F of 15 mm bore BALL VALVE / gate valve complete all as specified |
| 36 | S&F of 20 mm bore BALL VALVE / gate valve complete all as specified |
| 37 | S&F of 25 mm bore BALL VALVE / gate valve complete all as specified |
| 38 | Refixing old steel tubing, 15 mm bore, and connections with new or old position (Walls, ceiling, floors, etc.) Note :- Steel tubes obtained from Serial item No. 26.00 above shall be used under this item. |
| 39 | Refixing old steel tubing, 20 mm bore, and connections with new or old position (Walls, ceiling, floors, etc.) Note :- Steel tubes obtained from Serial item No. 27.00above shall be used under this item. |
| 40 | Refixing old steel tubing, 25 mm bore, and connections with new or old position (Walls, ceiling, floors, etc.) Note :- Steel tubes obtained from Serial item No. 28.00 above shall be used under this item. |
| 41 | Supply and laying 15 mm bore tubes, galvainzed steel, medium grade, with all fittings and fixed complete on walls and ceilings or laid in floors all as specified and directed. |
| 42 | Supply and laying 20 mm bore tubes, galvainzed steel, medium grade, with all fittings and fixed complete on walls and ceilings or laid in floors all as specified and directed. |
| 43 | Supply and laying 25 mm bore tubes, galvainzed steel, medium grade, with all fittings and fixed complete on walls and ceilings or laid in floors all as specified and directed. |
| 44 | S&F in repairs 20 mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gms) |
| 45 | S&F in repairs 25 mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gms) |
| 46 | Cutting holes in brick walls for inserting Water pipe line and making good dismantled portion by filling cement concrete 1:3:6 Type C-1 exc half brick but not exc one brick including existing surface finishes complete all as specified and directed |
| 47 | Cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good in cement mortar 1:3, cutting not exc 10cm girth as specified and directed. |
| 48 | S & F in repairs viterous China Wash down water closet Pan \"Pedestal Pattern\" white with seat cover white closet pattern with flat battom and cover mild steel chromium plated or aluminium anodised hinging device and joints etc and connection to drain, flushing, pipe, anti symphonage pipe and fixing arrangements with fixing bolts etc including making good the disturbed portion of floor in cement concerete 1:2:4 type (B-0) complete all as directed . |
| 49 | S & F in repairssquatting pan vitreous china orrisa pattern of Size 580mmx440mm \"white\" with integral foot rest (Excluding flushing cistern and flush pipe) including provision of cement concrete bedding, connection to trap and to flushing pipe, anti-syphonage pipe etc complete making good to floor complete all as specified and directed. |
| 50 | S&F in repair viterous china wall mounted wash down water closet pan (pedastal pattern)white including fixing bolts, flushing cistern concealed (with dual water storage capacity of 4ltr and 2 ltr) and flush pipe , P or S trap provision of flush pipe ,anti sypohonage pipe etc. with plastic water closet seat cover with soft close (white), complete all as specified and directed. |
| 51 | S&F in repair vitreous china floor mounted coupled closet (Pedestal pattern) white including low level vitreous china valveless syphonic action type flushing cistern with inlet ball valve float,push button, flush pipe incl bracket, P/S trap, PVC coloured seat cover and connecting fittingsincluding taking down existing water closet complete all as specified and directed.Make : CERA, Model : CALIBRE / ASIAN PAINTS, Model: PRIMUS / JAQUAR, Model: CONTINENTAL / HINDWARE, Model: ALPHA S 220 / PARRYWARE, Model: INDUS) |
| 52 | S&F in repairs 3 in 1 wall mounted mixer (15 mm bore) with quarter turn fittings and provision for overhead shower with 115 mm bend pipe & telephonic shower with 225mm long bend pipe and wall flange, cast copper alloy with capstan heads, fancy type chromium plated (robotic electro plating for everlasting lustrous shine) with 2 water volume adjustment knobs one both side to control the flow of temperature, screwed down, screwed for iron pipe or for brass ferrule and fixed includng neccesary fittings complete for mixing hot and cold water for tap and shower all as specified and directed by Engr-in-charge. Make : Hindware model no. F280018CP / Cera model no. F2002404 or equivalent |
| 53 | S&F in repairs brass center hole basin mixer with quarter turn fittings for mixing hot and cold water (15mm dia of bore), cast copper alloy, with capstan heads, fancy type chromium piated (robotic electroplating for everlasting lustrous shine), screwed down high pressure, with 2 water volume adjustment knobs one both side to control the flow of temperature, screwed for iron pipe and fixed brass chromium Concealed angle stop cock with wall flange of 15mm dia capastan head including neccesary fittings complete ali specified and directed by Engr-in-charge.Make : Hindware model no. F920034CP / Cera model no. F2002461 or equivalent |
| 54 | S&F in repairs PVC connection 15 mm dia 600mm long with 2 Nos PVC check nuts with washer complete all as specified and directed. |
| 55 | S&F in repairs PVC connection 15 mm dia 450mm long with 2 Nos PVC check nuts with washer complete all as specified and directed. |
| 56 | S&F in Pillar taps, 15mm dia fancy type with capstan heads,chromium plated screwed down high pressure with or without lettered HOT or COLD with long screwed shanks and fly nuts, screwed for iron pipe and fixed. |
| 57 | S&F in repairs 15mm dia of fancy type chromium plated one way/two way Anglestop valves , cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for unions and fixed complete all as specified and directed. |
| 58 | S&F in repairs of 15 mm borestop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed complete all as specified and directed. |
| 59 | S&F in repairs 15 mm dia bib tap cast copper alloy CP fancy type with capstan headlong body and cup screwed down for iron pipe all complete all as specified and directed. |
| 60 | S&F in repairs Mirror cabinet (PTMT) with mirror size 350mm x 450mm fixed on wall with cadmium plated brass screws, complete all as specified & directed. |
| 61 | S&F in repair for Brass chromium plated shower rose 125mm size with arm 15 mm bore complete all as specified and directed by Engineer-in-charge . |
| 62 | S & F in repairs viterous China Wash Hand Basinwhite, flat back, size 550 x 400mm including 15mm dia pillar tap, cast copper alloy, with capstan head cp, screwed down high pressure withor without letter Hot orColdwith long screwed shank and fly nut including PVC water pipe 32mm bore and PVC connection suitable for 15mm bore pipe 60cm long with nut and washers at both ends andcp waste coupling,including mild steel brackets, made out of 25mm X 25mm X 3mm thick angle iron of required length fixed to wallwith PCC type B-0 (1:2:4)including cutting for a pinning in a brackets complete all as directed by Engr-in-Charge. |
| 63 | S & F in repairs forPVC low level flushing cistern 10 Ltr capcity Valve lessduel symphonic action type, flushing cistern, low level white, with inlet ball valve flat and handle including PVC flush pipe 32mm bore and mild steel brackets made out of 25mm X 25mm X 3mm thick angle iron of required length fixed to wallwith PCC type B-0 (1:2:4) complete all as directed. |
| 64 | S & F in repairs hand shower (health faucet) ABS body mild steel chromium plated for 15mm dia, 1.25meter long flexible tube and ABS wall hook including making connections and fixed in postion complete in all respect as specified. |
| 65 | S&F in repairs vitreous china urinal, full stall type, white including providing & fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with & including 60 mm long brass screws, pointing around urinal back in cement, with & including PTMT grating and union for discharge pipe including waste pipe of polythelene of low or high density or PVC 32mm dia, complete all as specified & directed. Make : jaguar cat no. URS-WHT- 13253N , PRS-073 (with all necessary fittings required like flush valve connection pipe spreaders complete all as specified and directed |
| 66 | S&F in repairs 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers |
| 67 | S&F in repairs in repairs sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 600mm long all as specified and as directed. |
| 68 | S&F in repairs CP Tubular Towel Rail 600mm long including Chromium Plated brass screws and wooden/ plastic cleats (Minium weight 90 gm) |
| 69 | S&F in repairs CP Soap dish, approximate size 160X160X90mm complete all as specified & directed |
| 70 | S&F in repairs Toilet paper holder, CP box type complete all as specified & directed |
| 71 | S&F in repairs in repairs Grating doom 100-125mm dia with or without waste hole of PTMT and CP complete all as specified & directed (Minium weight 40 gm) |
| 72 | S & F in repairs for PVC waste coupling 32mm/100mm dia PTMT (half or full threaded) suitable for WHB/Sink (min wt 450 gms), completed all as specified & directed |
| 73 | S & F Decorative designer looking mirror of selected quality glass 5 mm thick of suitable size mounted on 2mm thick laminated PVC sheet with necessary fixing arrangement complete as directed. |
| 74 | S&F in repair 32mm dia PVC waste pipe for WHB & kitchen sink 80cm long with union complete all as specified and directed. |
| 75 | S&F in repairs 15mm bore Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15gm - 90gms complete all as specified & directed. |
| 76 | S&F in repair pillar tap standard of PTMT any colour high pressure screwed for iron pipe of 15 mm bore and fixed (Minimum weight 15gm - 110gms) |
| 77 | M&L for water proofing treatment on existing cleaned RCC roof in the following specification and manufacturer instruction complete all as secified and as directed(a) Applyingthe bitumen primer @ 0.25 Lit/Sqm over cleaned platser surfaces (b) Applying layer of APP based polymeric membrane 3.0mm thick (minimum) weighing 30 kilogram per sqm (reinforced with polyster non oven fabric weighing not less than 160gms per sqm by torch application The over laps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction (c) Applying one coat of aluminium paint @ 0.11 Litre per sqm ovrer APP based Polymeric membraneNote : (A) Complete removable of existing surface & the net area of water prooofing treatment shall be measured without any extra allowance for laps & portion inserted in groove which shall be deemed included in the quoted rates.(B) Plaster shall be measured and paid seperately. |
| 78 | M & L for rendeing 15mm thick screed bed on concrete surface in CM (1:4) mixed with 3% water proofing compound of cement used (by weight) surfaces finished fair and even complete, all as directed Note : WPC shall be measured and paid seperately. |
| 79 | Supply only integral water proofing compound all as specified and as directed. |
| 80 | M&L for PCC 1:2:4 type B-2 using 40 mm graded stone aggregate in foundations, floor base, filling and mass concrete all as directed |
| 81 | Dismantling wrought iron or mild steel work of any dscription not otherwise provided for completeall as specified anddirected. |
| 82 | M&L for Mild steel work in tubular trusses including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240, complete all as specified anddirected by Engineer-in-Charge.Note : The cost of nuts, bolts & washers for jointing to the members of trusses shall be deemed to beincluded in the quoted unit rate by tenderer . Nothing extra shall be admissible on this account. |
| 83 | Dismantling AC sheet (Corrugated, Semi corrugated etc) as in roofs etc complete all as specified |
| 84 | S&F for Galvalume zinc coated GI based corrugated sheet shall be 0.50mm thick (total coated thickness), 550 Mpa minimum, yield strength. It shall be coated with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having overall width and laid width as specified and shall be fixed using hot dip galvanized, self drilling and self tapping screws neoprene and EPDM washers.all as specified and directed. |
| 85 | S&F for Galvalume zinc coated GI based plain sheet shall be 0.50mm thick (total coated thickness), 550 Mpa minimum, yield strength. It shall be coated with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having overall width and laid width as specified and shall be fixed using hot dip galvanized, self drilling and self tapping screws neoprene and EPDM washers. all as specified and directed. |
| 86 | Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, any description including cover fillets |
| 87 | M&L for Non asbestos fibrecement building boards 4-6mm in thickness fixed orlaid/ inserted to timber/ GI/ Aluminium frame work with screws along with Anodised aluminium snap grid frame work for false ceiling Size of grid 605 x 605mm all as specified and directed. |
| 88 | S&F of Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20mm and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of26 mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. |
| 89 | Providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. wire mesh (Fillets, metal frame work and G.I. wire mesh paid separately) |
| 90 | Demolition of Concrete of any description and in anyposition any depth not otherwise specifically provided for complete all as specified and directed |
| 91 | M&L for cleaning to concrete/plastered surfacesof sunken slab and applying water proofing treatment in the following courses : (a) Two coats of epoxy resin / polymer modified cementaticious coating like brush bond of Fosroc or equivalent both on floor and walls / beams shall be applied as per manufacturer\"s instructions. (b) Slabs to be given 1:20 slope outwards with 25mm Gl pipe spout with 300mm projection beyond outer surface of wall complete all as specified and directed by Engineer-in Charge. |
| 92 | M&L for cement concrete(1:3:6) using cinder, up to the required depth as Surrounding to WC Pan as specified and directed by Engineer-in Charge. |
| 93 | M&L for rendering of Top of RCC slab in sunken portion including peripheral beams shall be plastered with 15mm thick cement and sand mortar (1:3) using approved water proofing compound @ 3% by weight of cement finished even and smooth without using extra cement and curved adequately and allowed to drycomplete all as specified and as directed by Engr-In-Charge. |
| 94 | Dismantling CI/AC/PVC (SWR) pipes & fittings of any description fixed to wall/laid in trenches including making good disturbed portion of wall floor etc. |
| 95 | S&F 110 mm dia PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floorincluding all fitting fixture like clamps fixing in wall & floor etc complete all as specified and directed by Engineer-in Charge. |
| 96 | S & F in repairs 110 mm dia PVC (SWR) bends any radius, with access door complete all as specified and directed by Engineer-in Charge. |
| 97 | S & F in repairs 110 mm dia PVC (SWR) bends any radius, without access door complete all as specified and directed by Engineer-in Charge. |
| 98 | S & F in repairs PVC (SWR) junction single/double as required (single/double T) equal or unequal 110mm bore, withoutaccess doorcomplete all as specified and directed by Engr-in-charge. |
| 99 | S & F in repairs PVC (SWR) junction single/double as required (single/double T) equal or unequal 110mm bore, withaccess doorcomplete all as specified and directed by Engr-in-charge. |
| 100 | S & F in repairs PVC (SWR) junction single/double as required (single/doubleY) equal or unequal 110mm bore, withaccess doorcomplete all as specified and directed by Engr-in-charge. |
| 101 | Taking down floor trap/nahani trap of any description any size and making good to disturbed portion with cement concrete type B-1 1:2:4 with water proofing compound complete all as specified and directed. |
| 102 | M&L for 75mm outlet dia PVC(SWR)floor trap, plainwith grating including jointing with solvent cementall as specified and directed. |
| 103 | S & F 75 mm dia PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floorincludin all fitting fixture like clamps fixing in wall & floor etc complete all as specified and directed by Engineer-in Charge. |
| 104 | S & F in repairs 75 mm dia PVC (SWR) bends any radius, with access door including all fitting fixture like clamps fixing in wall & floor etc complete all as specified and directed by Engineer-in Charge. |
| 105 | S & F in repairs 75 mm dia PVC (SWR) bends any radius, without access doorincluding all fitting fixture like clamps fixing in wall & floor etc complete all as specified and directed by Engineer-in Charge. |
| 106 | Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars etc complete all as specified and as directed. |
| 107 | M&L for brick work with sub class B bricks burnt straight or curved on plan exc 6 M mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 108 | M&Lfor Taking down cement plaster in any descriptionon brick or stone wall etc incl racking outjoints.hacking for key scrubbing down with water etc. all as specified andas directed by Engr-in-Charge. |
| 109 | M & L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick concrete on internal surface finished even and smooth without using extra cement |
| 110 | M&L for 15 mm thick rendering in cement mortar (1:6) on brick or concrete surfaces finished even and smooth without using extra cementcomplete all as specified anddirected. |
| 111 | M&L for applying three coats of white wash on walls including preparation of newly plastered surfaces. |
| 112 | M&Lforapplying one coat of white wash to old decorated (white washed) surfaces of wall including preparation of surface (by brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss, efflorescent salts, trading oil and greasy spots) complete all as specified and directed by Engineer -in-Charge. |
| 113 | M&L for complete removal of existing treatment of old wall surface and applying two coats of oil bound distemper over a coat of alkali resistant primer applied over 2 to 3 mm thick BIRLA/JK water proof wall care putty complete all as directed by Engr-in-charge. |
| 114 | M&L forapplying one coat of oil bound distemper to old decorated (distempered) surfaces of ceiling including preparation of surface (by brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss, efflorescent salts, trading oil and greasy spots) complete all as specified and directed by Engineer -in-Charge. |
| 115 | M&L for applying one coat of cement base paint to old decorated (cement base painted) surfaces of wall including preparation of surface (by brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss, efflorescent salts, trading oil and greasy spots) painting shall be applied post curing, curing done shall be complete all as specified and directed by Engineer -in-Charge. |
| 116 | S&F solid PVC Wall Lining consisting of 5mm thick wood grain printedPVC sheet inclusive of solvent cement/adhesiveand fixing at site on PVC/woodenframe as per specifications and drawing given in SSR. Note : PVC Filletsshall be measured and paid separately. |
| 117 | S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specifications and drawing given in SSR and as directed. |
| 118 | M&L for second class soft wood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or brads, sectional area exc 6 sqcm and not exc 13 Sqcm including tarring complete all as specified. |
| 119 | S&F in repairs of 15mmSS Jet spray L bend (American with 1 Mtr. Tube)complete all as specified and directed by Engineer-in-Charge.Make : prayag cat no. CPJ -6/7 |
| 120 | S&Fin repairs plastic water closet seat cover, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminized hinge device (Anglo indian) complete all as specified and as directed. Make : Johnson pedder / parryware/ cera. |
| 121 | S&F in repair of Seat cover for wall mounted / floor mountedwash down water closet pan (pedastal pattern) as required colour, shape & size complete all as specified and directed by Engineer -in-Charge.Note : Hindware/ prayag etc |
| 122 | S&F in repair for stainless steel plate rack for kitchen utensil made out of 0.50 mm thick stainless sheeet and over all size 600x750mm and 250 mm depth fixed to wall with screws complete all as specified and as directed. |
| 123 | S&F in reapiar Sink with drainage board made of stainless steel 1mm thick for kitchen with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or with & including fixing cantilever brackets and connecting union to pipe, overall size 915 x 460 mm bowl size 410 x 330 x160 mm including waste pipe of polythelene of low or high density or PVC 32mm dia & waste fitting brass chromium plated for 32mm bore with long screwed shanks and fly nuts including making holes in stone walls for brackets and fixed in CM (1:3) or PCC (1:2:4) type B0 including taking down old unserviceable sink complete all as specified and directed. |
| 124 | S&F in repairs sinks made of stainless steel 01mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed. |
| 125 | S&F in repair of 32 mm bore Low density polyethylene (LDPE) pipes of pressure rating 6 kgf/sq. cm complete all as specified and as directed. |
| 126 | S&F in repairs of 75/110 mm bore PVC (SWR) vent cowl complete all as specified and as directed. |
| 127 | M&L for cleaning ofbuilding service tanks PVC of OMQ & SMQ areaof exe. 250 litres and not exe. 500 litres capacity situated at various places by involving the following four (4) stages of cleaning process shall be carried out as given below :- a) De-watering PVCtankthrough wash out pipe completely. b) Total removal of sludges completely.c) Cleaning of walls,ceiling and floor & inspecting for craks if any completely.d) Antibacterial treatment of inside of tankto make it bacteria free completely.Note : (i) Entire T&P shouldbe arranged by the contractor at their own. Only electric power & water shall be supplied by MES at stipulated rate. (ii) Date of cleaning, should be written over the outer surface of tank by synthetic enamel paint with lettering not less than 100 mm height. Cost of the same is deemed inclusive in the quoted unit rate of cleaning of tank. |
| 128 | All as per Serial Item No.127.00 here in above but capacity of tank exc. 500 litres and not exc. 1000 litres. |
| 129 | Labour only for repair of flushing cistern and changing of unseviceable part and replaced with same as required like bend pipe flush handle ball valve etc complete all as specified and directed. |
| 130 | Material & labour for preparing old exterior emulsion paint surfaces of walls by washing, rubbing down stopping of painted surfaces and applying one coat of exterior emulsion paint weather coat, complete all as specified and as directed. |
| 131 | M&Lforapplying two coats of synthetic enamel paint to new steel surfaces of any description over 10 cm width or girth over a coat of red oxide including preparation of surfaces all as specified and directed by Engineer -in-Charge. |
| 132 | M&L for cement concrete 1:3:6 type C-2 (40mm aggregate) columns, pillar and postsetc. complete all as specified and directed by Engr in Charge. |
| 133 | M&L for applying one coat of oil bound distemper to old decorated (distempered) surfaces of wall including preparation of surface (by brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss, efflorescent salts, trading oil and greasy spots) complete all as specified and directed by Engineer -in-Charge. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy