Tender For General-Amc - 2025-2026. Pattimattom Area.-Fully Comprehensive Annual Maintenance Of Erappanpara, Kandattukunnu,Karamootil,Kuttah,Nedumala,Palathali,Neelimala,Ennakamolam,Ambedkarhc,Airapuram,Chakkothumala,And Gandhigram Li Scheme Under Electrical Li Section Aluva-General Electrical Work-General Electrical Work Overhauling 2 OD297288/2024-2025:Dismantling the11-30 HP motor into stator and rotor, cleaning the windings attending minor repairs, re taping the coils if necessary, varnishing the coils with best quality insulation varnish, cleaning and greasing the bearings with good quality grease, heating the windings, reassembling, refitting the motor in position coupling with pump correcting alignment and giving connection, test running with full load including scrapping, cleaning and painting the motor pumpset, base plate etc.with enamel paint. 3 OD297287/2024-2025:Dismantling the 31-60 HP motor into stator and rotor, cleaning the windings attending minor repairs, re taping the coils if necessary, varnishing the coils with best quality insulation varnish, cleaning and greasing the bearings with good quality grease, heating the windings, reassembling, refitting the motor in position coupling with pump correcting alignment and giving connection, test running with full load including scrapping, cleaning and painting the motor pumpset, base plate etc.with enamel paint. 4 Consumables and supplies 5 OD117614/2025-2026:Supply of following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel. making connections. etc. as required. 4 pole MCCB,125A,36KA 6 OD185395/2025-2026:Replacing the damaged bearing , supply and fixing new ball/Roller bearing , SKF / FAG make as per the direction of departmental staff at site - Bearing No 6310 or its equivalent size 7 OD117615/2025-2026:MCCB Accessories. Supply of one number earth fault Relay up to 125A to 200A with CBCT. 8 OD118621/2025-2026:Supplying 5A to 32 A rating, 240/415 volts, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 9 OD47964/2025-2026:Supply and fitting Three Phase Ammeter accuracy class 1 10 OD47965/2025-2026:Supply and fitting Three Phase Voltmeter accuracy class 1 11 OD47966/2025-2026:Supply and fitting Digital multifunction meter to read VA,PF,KW,KWh, accuracy class-1 LCD 12 OD297276/2024-2025:Supply and providing 7W LED Bulb in the existing holder as required 13 OD118622/2025-2026:Supply of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 14 OD297273/2024-2025:Supply and filling of transformer oil of good quality to the Transformer /starter/ regulator etc as required 15 OD297275/2024-2025:Supply and providing of LED Indication lamps in panel board-blue colour 16 OD297277/2024-2025:Supply and providing LED indicators for all voltage ranges - Red, Green, Black, Yellow or Orange Colour 17 OD297278/2024-2025:Supply and providing 5 Kg. Dry Chemical Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required. 18 OD297282/2024-2025:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection7.5 KVAr, 3 phase, 440 V, delta connected Metalised Poly Propylene Capacitor, Cylinderical Type, suitable for direct connection to motors. 19 OD47969/2025-2026:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection 6 KVAr, 3 phase, 440 V, delta connected Metalised Poly Propylene Capacitor, Cylinderical Type, suitable for direct connection to motors 20 OD297283/2024-2025:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection 2KVAr, 3 phase, 440 V, delta connected Metalised Poly Propylene Capacitor, Cylinderical Type, suitable for direct connection to motors. 21 OD297284/2024-2025:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection. 1 KVAr, 3 phase, 440 V, delta connected Metalised Poly Propylene Capacitor, Cylinderical Type, suitable for direct connection to motors. 22 OD140077/2025-2026:Dismantling the existing MS Suction/Delivery pipe, bend of size 100/150 mm piece by piece after providing scaffolding supports and stacking at the yard 23 OD297285/2024-2025:Charges for demolishing the existing damaged concrete foundation under the floor using special tools and deposit the demolished concrete blocks outside the pump house 24 OD47976/2025-2026:Supply, fabrication, conveyance, fixing, testing and commissioning of 100 mm size MS pipe bend with 12 mm thick flanges at both end, fabricated from 100 mm MS pipe having 6.35 mm sheet thickness, with length not less than 0.45 meter, painting two coats of synthetic enamel paint over a coat of red oxide primer and fixing in position using fresh rubber packing, gasket packing, bolts and nuts etc. in correct alignment and leak proof condition. 25 OD47977/2025-2026:Supply, conveying, erecting, testing and commissioning the 100 mm dia MS pipe in suction/ delivery side having sheet of minimumthickness 6.35 mm and cutting in to required length, facing the cutting edges, painting two coats of synthetic best quality enamel paint over a coats red oxide primer, including conveyance charges to pump house and labour charges for loading, unloading,etc. 26 OD55197/2025-2026:Supply and providing the rough cut flange ring joint 12 mm thick for 100/150 mm MS pipe after facing the cutting edges of flange rings neatly and set out the flange rings in correct position to both vertical and horizontal planes and welding in two rows accurately, painting two coats of synthetic best quality enamel paint over a coats red oxide primer including fixing the pipe using suitable size nuts and bolts , rubber packing grease etc , in correct alignment and leakproof condition. 27 14.8:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required. 28 14.11:Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels. 29 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels 30 OD297281/2024-2025:supply and providing ABRO PUF -750 Multipurpose Expandable PU Foam insulation Sealant Spray. 31 OD117618/2025-2026: Supply and installation CI Non Return Valve, Conforming to IS 5312 Part I - 1984, PN 1.6, Size 100mm. 32 OD117617/2025-2026: Supply and installation of 150mm CI Non Return Valve with cast Iron double flange as per IS/5312 PN 1.6 rating complete with Gland packing, Rubber gasket etc. 33 OD54618/2025-2026:Dismantling the existing MS Suction/Delivery pipe, bend of size 200/250 mm piece by piece after providing scaffolding supports and stacking at the yard 34 OD54667/2025-2026:Supply, conveying, erecting, testing and commissioning the 250 mm dia MS pipe in suction/ delivery side having sheet of minimum thickness 6.35 mm and cutting in to required length, facing the cutting edges, painting two coats of synthetic best quality enamel paint over a coats red oxide primer, including conveyance charges to pump house and labor charges for loading, unloading etc. 35 OD55146/2025-2026:Supply and Fitting of MS flange complete with Gland packing, Rubber gasket 250mm dia 36 OD135906/2025-2026:Supply and providing Taparia make Combination Plier (210mm)-1no ,insulated screwdriver (250mm)-1no,Line tester(200mm)-1no,Double Ended Spanner Set DEP12 (12 Pcs),6x7, 8x9, 10x11, 12x13, 14x15, 16x17, 18x19, 20x22, 21x23, 24x27, 25x28, 30x32 mm, electrical SafetyRubber hand Gloves-1pair 37 OD135908/2025-2026:Charges to be paid at electrical inspectorate/kseb actual amount may be reimbursed on production of original documents 38 OD135909/2025-2026:Copying Charges of electrical drawing per A3 Sheet additional Copies 39 OD135910/2025-2026:Charges for preparation of electrical drawing per A3 Sheet first sheet 40 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board 41 AMC of motor pump sets 42 OD297289/2024-2025:Fully Comprehensive Annual Maintenance of upto 5 HP Vacuum motor pump set , D.O.L starter ,controlling electrical accessories , etc complete for a period of 12 months including attending all repairs , reconditioning the damaged parts, replacing spares with original make as per sample, dismantling and refitting , removing foreign bodies , renewal of gland packing , gasket packing , rubber packing , greasing the bearing etc as and when required including overhauling of pump, overhauling of the motor, maintenance of motor thorughout the AMC period whenver necessary (excluding rewinding) repairs of vaccum pipe line, starter, valves electrical accessories etc as required complete in good working condition including painting the motor pumpset, base plate all time during the period of contract and the faults should be rectified with in the time allowed 43 OD297291/2024-2025: Fully Comprehensive Annual Maintenance of 11-30 HP Slip ring induction motor with split case / End suction pump set , starter, controlling electrical accessories , panel board,etc complete for a period of 12 months including attending all repairs ,overhauling & reconditioning of starter , replacing of damaged contacts, no volt relese coil, overload coil, reconditioning and refil oil, reconditioning the slipring unit as required, overhauling of panel board by checking the wire connections, control wiring, servicing of switch geares as required, replacing the burnout fuse links, repair the damaged hinges replacing wornout beedings including painting etc. replacing the damaged coupling bush, carbon brush and coupling bolts, Overhauling and reconditioning the pumpset by reconditioning the damaged parts , replacing spares with original make as per sample , removing foreign bodies , renewal of gland packing , gasket packing , rubber packing , greasing the bearing etc as and when required, painting the starter, base palte, pumpset and maintain the motor pump sets starter , electrical accessories etc complete in good working condition all time during the period of contract and the faults should be rectified with in the time allowed . 44 OD297293/2024-2025: Fully Comprehensive Annual Maintenance of 11-30 HP squirrel cage induction motor with split case / End suction pump set , starter, controlling electrical accessories , panel board,etc complete for a period of 12 months including attending all repairs ,overhauling & reconditioning of starter , replacing of damaged contacts, no volt relese coil, overload coil, reconditioning and refil oil, overhauling of panel board by checking the wire connections, control wiring, servicing of switch geares as required, replacing the burnout fuse links, repair the damaged hinges replacing wornout beedings including painting etc. replacing the damaged coupling bush, and coupling bolts, Overhauling and reconditioning the pumpset by reconditioning the damaged parts , replacing spares with original make as per sample , removing foreign bodies , renewal of gland packing , gasket packing , rubber packing , greasing the bearing etc as and when required, painting the starter, base palte, pumpset and maintain the motor pump sets starter , electrical accessories etc complete in good working condition all time during the period of contract and the faults should be rectified with in the time allowed . 45 OD297292/2024-2025: Fully Comprehensive Annual Maintenance of 31-60 HP squirrel cage induction motor with split case / End suction pump set , starter, controlling electrical accessories , panel board,etc complete for a period of 12 months including attending all repairs ,overhauling & reconditioning of starter , replacing of damaged contacts, no volt relese coil, overload coil, reconditioning and refil oil, overhauling of panel board by checking the wire connections, control wiring, servicing of switch geares as required, replacing the burnout fuse links, repair the damaged hinges replacing wornout beedings including painting etc. replacing the damaged coupling bush, and coupling bolts, Overhauling and reconditioning the pumpset by reconditioning the damaged parts , replacing spares with original make as per sample , removing foreign bodies , renewal of gland packing , gasket packing , rubber packing , greasing the bearing etc as and when required, painting the starter, base palte, pumpset and maintain the motor pump sets starter , electrical accessories etc complete in good working condition all time during the period of contract and the faults should be rectified with in the time allowed . 46 OD297290/2024-2025: Fully Comprehensive Annual Maintenance of 31-60 HP Slip ring induction motor with split case / End suction pump set , starter, controlling electrical accessories , panel board,etc complete for a period of 12 months including attending all repairs ,overhauling & reconditioning of starter , replacing of damaged contacts, no volt relese coil, overload coil, reconditioning and refil oil, reconditioning the slipring unit as required, overhauling of panel board by checking the wire connections, control wiring, servicing of switch geares as required, replacing the burnout fuse links, repair the damaged hinges replacing wornout beedings including painting etc. replacing the damaged coupling bush, carbon brush and coupling bolts, Overhauling and reconditioning the pumpset by reconditioning the damaged parts , replacing spares with original make as per sample , removing foreign bodies , renewal of gland packing , gasket packing , rubber packing , greasing the bearing etc as and when required, painting the starter, base palte, pumpset and maintain the motor pump sets starter , electrical accessories etc complete in good working condition all time during the period of contract and the faults should be rectified with in the time allowed . Please Enable Macros to View BoQ information