| 1 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 2 | Asbestos Cement sheet |
| 3 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 4 | Of area 3 sq. metres and below |
| 5 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 6 | Nominal concrete 1:3:6 or richer mix (including equivalent design mix) |
| 7 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 8 | For thickness of tiles 10 mm to 25 mm |
| 9 | Earth work in surface excavationnot exceeding 30 cm in depthbut exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lif upto 1.5 m, as directed by Engineer-in- Charge: |
| 10 | All kinds of soil |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 12 | Foundations,footings,basesof columns,etc.formass concrete |
| 13 | Walls (anythickness)includingattachedpilasters, butteresses, plinth and string courses etc. |
| 14 | Suspended floors,roofs,landings,balconies and access platform |
| 15 | Shelves (Cast in situ) |
| 16 | Lintels,beams,plinthbeams,girders,bressumersand cantilevers |
| 17 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 18 | Providingandlayinginpositioncementconcreteof specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 19 | 1:1.5:3 (1Cement: 1.5 coarsesand (zone-Ill)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 20 | 1:3:6 (1Cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 21 | Steelreinforcement forR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete upto plinth level. |
| 22 | Thermo-Mechanically Treatedbars of gradeFe-500D or more. |
| 23 | Steelreinforcement forR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete above plinth level. |
| 24 | Thermo-Mechanically Treatedbars of gradeFe-500D or more. |
| 25 | Reinforced cement concrete work in walls (any thickness),including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor fivelevel,excludingcost of centering,shuttering, finishingand reinforcement: |
| 26 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 27 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 28 | Electric resistance or induction butt welded tubes |
| 29 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 30 | Providing and fixingup to floor five levelprecast cement concrete hollow block,including hoisting and setting in position with cement mortar 1:3 (1cement : 3 coarse sand), cost of required centering, shuttering complete. |
| 31 | 1:1.5:3 (1Cement: 1.5 coarsesand (zone-Ill)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) . |
| 32 | 12 mm cement plaster of mix: |
| 33 | 1:4(1 cement: 4 fine sand) |
| 34 | Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). |
| 35 | Providingand fixingplainmultipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately). |
| 36 | 6 mm thick Cement fiber board, Type-B, Category-III as per IS: 14862 :2000 |
| 37 | Providing andlayingCeramic glazed floor tiles of size 300x300mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 38 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3(1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 39 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite)soliddoor/window/Clerestorywindows&otherFrames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A categorywithpropertyofbeingtermite/borerproof,water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and lengthcomplete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.edepth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 40 | Frame size 65 x 100 mm |
| 41 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimumcompressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 42 | 35 mm thick |
| 43 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
| 44 | Polished Granite stone slab of colour Black,Cherry/Ruby Red or equivalent |
| 45 | Makingplinthprotection 50mmthickofcementconcrete 1:3:6 (1cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 46 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 47 | Fixed to openings /wooden frames with rawl plugs screws etc. |
| 48 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) |
| 49 | 300x16 mm |
| 50 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 51 | 250x10 mm |
| 52 | 150x10 mm |
| 53 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 54 | 125 mm |
| 55 | Providing and fixing M.S. fan clamp type I or ll of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. |
| 56 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 57 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 58 | Finishing walls with Acrylic Smooth exterior paint of required shade: |
| 59 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 60 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture,including applying additional coats wherever required, to achieve even shade and colour. |
| 61 | Two coats |
| 62 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 63 | Two or more coats on new work |
| 64 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : |
| 65 | Rectangular shape 453x357 mm |
| 66 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 67 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 68 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 69 | ProvidingandfixingChlorinatedPolyvinylChloride(CPVC)pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. |
| 70 | 20 mm nominal dia Pipes |
| 71 | 32 mm nominal dia Pipes |
| 72 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall |
| 73 | 50 mm nominal dia Pipes |
| 74 | 32 mm nominal dia Pipes |
| 75 | 20 mm nominal dia Pipes |
| 76 | Providing and placing on terrace (at all floor levels) polyethylene water storagetank,IS : 12701marked,withcoverandsuitablelocking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 77 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 78 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 79 | Providing and fixing brass bib cock of approved quality : |
| 80 | 20 mm nominal bore |
| 81 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 82 | 20 mm nominal bore |
| 83 | 25 mm nominal bore |
| 84 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 85 | 15 mm nominal bore |
| 86 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 87 | W.C. pan with ISI marked white solid plastic seat and lid |
| 88 | Providing and fixing pre-painted galvalume (PPGL) steel profile sheets AZ-150 of brand Tata Bluescope steel, Everest Industries Ltd., JSW Steel Ltd., Jindal India Ltd. or equivalent (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with aluminium zinc coating 150 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tappingscrews (Xylan) of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 89 | Providing and fixing pre-painted galvalume (PPGL) steel profile sheets AZ-150 of brand Tata Bluescope steel, Everest Industries Ltd., JSW Steel Ltd., Jindal India Ltd. or equivalent (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with aluminium Zinc coating 150 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 90 | Ridges plain (500 - 600mm). |
| 91 | Barge board (Upto 300 mm) |
| 92 | Providing and fixing 3 mm dia. G.I. level adjusting hangers (between 600 mm upto 1200mm length), fixed/tied to roof truss complete as per direction of Engineer-in-charge. |
| 93 | Providing and fixing WPC (wood polymer composite) board pelmet out of 18mm thick, 150mm width, edge glued, finger jointed WPC baord as planks finished with polishing melamine (honey colour) and necessary stainless steel curtain rod and bracket and other required fittings as per the direction of Engineer-in-charge. |
| 94 | Providing and fixing stainless steel hanging floor door stopper, ISI marked with necessary screws etc. complete. |
| 95 | Twin rubber stopper |
| 96 | Providing and fixing soil, waste and vent pipes with UPVC pipe conforming to IS : 13592 Type Bincluding jointingof pipes & fittings with one step solvent and testing of joints complete as per direction of Engineer-in-charge. (i) Single socketed pipes |
| 97 | 110 mm dia |
| 98 | 75 mm dia |
| 99 | 50 mm dia |
| 100 | Providing and fixing UPVC moulded door bend of required degree with access door insertion rubber washer 3 mm thick, bolts and nuts complete for UPVC soil pipes conforming to IS : 14735Type B including jointingof pipes & fittings with one step solvent and testing of joints complete as per direction of Engineer-in-charge. |
| 101 | 110 mm |
| 102 | 75 mm |
| 103 | 50 mm |
| 104 | Providing and fixing UPVC moulded plain bend of required degree for UPVC soil pipes conforming to IS : 14735Type B including jointingof pipes & fittings with one step solvent and testing of joints complete as per direction of Engineer-in-charge. |
| 105 | 110 mm |
| 106 | 75 mm |
| 107 | 50 mm |
| 108 | Providing and fixing UPVC moulded single equaljunction with door of required degree for UPVC soil pipes conforming to IS : 14735Type B including jointingof pipes & fittings with one step solvent and testing of joints complete as per direction of Engineer-in-charge. |
| 109 | 110x110x110 mm |
| 110 | Providing and fixing UPVC terminal guard for UPVC soil pipes conforming to IS : 14735Type B including jointingof pipes & fittings with one step solvent and testing of joints complete as per direction of Engineer-in-charge. |
| 111 | 110 mm |
| 112 | Providing and fixing UPVC pipe clips of approved design to UPVC pipes with screws of required length etc. complete as per the direction of Engineer-in-charge. |
| 113 | 110 mm |
| 114 | 75 mm |
| 115 | Providing, supplying and fixing cot of size 1x2 mtr made up of Ornamental hard wood cat-IA (Paduak) jointed processed as per the specification including cutting, shaping and grinding upto required size and finished with two coats of sanding sealer, two coats of NC filler & PU/mealamine polish of desired shade with machine spray including topped with 12mm thick marine plywood (IS:710) etc complete as per the direction of Engineer-incharge. |
| 116 | Constructing masonry Chamber 30x30x50 cm inside, in cement concrete solid block size of 400x150x200mm work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in reinforced cement concrete slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominalsize),i/cnecessaryexcavation,foundationconcrete 1:5:10) 1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : |