| 1 | CIVIL WORK FOR FACTORY SHED |
| 2 | Excavation for foundation in earth, soil of all types, sand, gravel, and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation, and necessary backfilling, ramming, watering including shoring and strutting etc. complete. (Lift up to 1.5 m.) By Mechanical Means |
| 3 | Excavation for foundation in earth, soil of all types, sand, gravel, and soft murum, including removing the excavated material up to a distance of 50 meters beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming, watering including shoring and strutting, etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means |
| 4 | Filling in plinth and floors with approved excavated material in 15cm to 20cm layers, including watering and compacting, etc. Complete. |
| 5 | Filling in plinth and floors with contractor\"s material/brought from outside and approved by Engineer in charge in layers of 15cm to 20cm including watering and compaction etc. complete. |
| 6 | Providing soling using 80mm size trap metal in 15cm layer including filling voids with crushed sand/grit, ramming, watering, etc. complete. |
| 7 | Providing pre-constructional anti-termite treatment as per I.S. 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorpyrifos per one square metre of vertical surface area covering 10 years guarantee on bond paper |
| 8 | (P.C.C. FOR FOOTING ) Providing and laying cast in-situ/Ready Mix cement concrete in M-10 of trap/granite/quartzite/gneiss metal for foundation and bedding including bailing out water, steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required, and curing complete, with fully automatic microprocessor-based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 9 | (FOOTING CONCRETE ) Providing and laying cast in-situ/Ready Mix cement concrete M-25 of trap/granite/quartzite/gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage, and footings of R.C.C. columns and steel stanchions, etc. including bailing out water, steel centering, formwork, cover blocks, laying/pumping, compaction, and curing, roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic microprocessor-based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). |
| 10 | ( COLUMNS CONCRETE )Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/granite/quartzite/gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed, including steel centering, formwork, cover blocks, laying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided, and curing, etc. complete, (Excluding reinforcement and structural steel). with fully automatic microprocessor-based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). |
| 11 | ( PLINTH BEAMS CONCRETE )Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/granite/quartzite/gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed, including steel centering, formwork, cover blocks, laying/pumping, compaction, and roughening the surface if special finish is to be provided, and curing, etc. complete. (Excluding reinforcement and structural steel). with fully automatic microprocessor-based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). |
| 12 | Providing and fixing in position TMT-FE-500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams, columns, canopies, staircase, newels, chajjas, lintels, pardis, copings, fins, arches, etc. as per detailed designs, drawings, and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding, and supporting as required, complete. |
| 13 | ( TREMIX FLOOR CONCRETE WORK ) Providing and layingin situ cement concrete M20 with TREMIX TREATMENT for 100 MM thickness for flooring with groove cutting of 4mm wide and 20 mm deepwith necessary refilling with bitumen etc. complete. |
| 14 | (Brick Work) Providing second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/in plinth external walls, including bailing out water manually, striking joints on unexposed faces, raking out joints on exposed faces, and watering, etc. Complete |
| 15 | ( BRICK WORK ) Providing second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete |
| 16 | ( INTERNAL PLASTER ) Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, etc. complete. |
| 17 | ( EXTERNAL PLASTER ) Providing sand-faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15mm thick in cement mortar 1:4 using waterproofing compound at 1 Kilogram per cement bag, curing the same for not less than 2 days, and keeping the surface of the base coat rough to receive the sand-faced treatment 6 to 8mm thick in cement mortar 1:4, finishing the surface by taking out grains and curing for fourteen days, scaffolding, etc. Complete. |
| 18 | Providing and applying white-wash in two coats on old/newplaster do rmasonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. |
| 19 | Providing and applying colour-wash ..of approved colour and shade in one coat to old surfaces which are to be recoloured including scaffolding, brushing and brooming down. (excluding base coat of white wash) etc. complete. |
| 20 | Providing and fixing mildsteel grill work for windows, ventilators ,etc.15Kilogram/One Square Metre asper drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete. |
| 21 | Providingand laying Cast in situ / Ready Mix cement concrete M-20 of trap/ granite /quartzite /gneiss metal for R .C.C .chajja asper detailed design and drawings including steel centering, formwork, coverblocks ,laying /pumping, compacting and roughening the surface if special finish to beprovidedandcuringcomplete. (Excludingreinforcementandstructuralsteel) .withfullyautomaticmicroprocessorbasedPLCwithSCADAenabledreversibleDrumTypemixer/concreteBatchmixplant(Panmixer)etc.complete. With fine aggregate (Crushed sand VSI Grade) |
| 22 | MS STRUCTURAL WORK Providing structural steel work in trusses, other similar trussed purlins and members with all bracing,gusset platesetc.asper detaileddesignsanddrawingsoras directedincluding cutting, fabricating,hoisting,erecting fixinginposition,Makingriveted/ bolted/welded connectionandone coat of anticorrosive paint and over it2 coats of oil painting approved quality and shade etc. |
| 23 | Providing and fixing 45 cm wide mild steel ladder of 40mm x 6 mm mild steel flat stringers andstepsof18 mmdia.mildsteelbarfor watertankincludingfixing itin(1:2:4)M-15 cementconcrete block60cmx30cmx30cmandpaintingtheladdercomplete. |
| 24 | Providing and fixing corrugated galvanised iron sheets of0.63 mm thick (24 B.W.G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers as per drawing etc. complete. (Weight of 5.5 kg / sqm.) |
| 25 | Supply & Fixing of 0.5 mm thk PPGL roof accessories as per drawing or as directed by engineer incharge- Center Ridge |
| 26 | Roof Gutter |
| 27 | Supplying, fabricating and erecting in position PPGI Eaves Gutter of required size with stop ends,all fixing accessories, drop ends, etc., at all elevations levels & heights including aligning, leveling, providing and fixing bolts, nuts, washers etc., conforming to latest specification including straightening, cutting, welding, bending to shape, bolting etc., complete and as directed as per engineer incharge |
| 28 | Providing and fixing of the rain water down take pipes of PPGI, the sectional area of rain water down take pipes provided shall be generally at the rate of 1 square cm per 70 to 80 square decimetre of roof area drained. No spout shall be less than 80 mm in diameter. The spacing of spouts shall be arranged to suit the position of openings in the wall including necessary accessories for fixing the pipe and including all materials and labour charges etc., complete as shown in drawings, as per specifications and as directed by the Engineer-in-Charge / |
| 29 | Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9mm with lock plate of 3.15mm thickness, reinforced with 35x35x5mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65mm and 3.15mm respectively with holdfast arrangements, M.S. Bracket plate 300x300x3.15mm minimum size and shape with square bar, suspension shaft of minimum 32mm diameter, hood cover of M.S. sheet not less than 0.9mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high-grade cast iron or mild steel and one coat of red lead primer, etc. complete. (I.S. 6248-1979) (Without mechanical gear) |
| 30 | ROYALTY CHARGES FOR SAND |
| 31 | FOR METAL |
| 32 | FORMUROOM |
| 33 | LAB TESTING CHARGES Cement - Fineness,Standard Consistency, Setting Time (Initial & Final ), Compressive strength, Soundness |
| 34 | Concrete M-25 - Mix Design with all tests on basic materials |
| 35 | Concrete M-25, M20 and M-10 grade - Concretecompressive strength |
| 36 | Crushed metal - Water absorption, Specific gravity,Impact value,Crushing value |
| 37 | Brick - Crushing value, Water absorbation, & Specific Gravity |
| 38 | Steel - Tensile strength ,Yield stress, ultimate tensile stress, %elongation, weight per running meter,Bend/Rebend test.(Set of 3 Bars) |
| 39 | Murum - Plasticity Index & Murum - Field Density of compacted layer |
| 40 | Sand Test -Sieve Analysis & Sand Test -Silk Connect Test |
| 41 | ELECTRICAL WORKS Supplying and erecting mains with 3 x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit / trunking / inside pole / Bus bars or any other places as perspecification No: WG-MA/BW |
| 42 | Supplying and erecting LED Panel Light (600mm X 600mm) Max. 30having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min. 3600 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%,p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with |
| 43 | Point wiring in for light/fan/bell in 20 mm metal conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, flush type switch, earthing and required accessories as perspecification No: WG-PW/SW |
| 44 | Supplying and erecting steel tubular swaged pole 139.7 x114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75 m) length respectively and total 8.0 m long with pole cap, base plate in provided foundation. (weight 101 kg) as per specification no. OH- PL/STP |
| 45 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP |
| 46 | Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testingand recording the results as per specification no. EA-EP |
| 47 | Supplying, erecting & marking DP-MCB 6A to 32A, C- series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specificationno. SW-SWR/MCB |
| 48 | Supplying, erecting & marking DP-MCB 6 A to 32 A, B- series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specificationno. SW-SWR / MCB |
| 49 | Supplying and erecting GI sheet 1.6 mm (16 SWG) having zinc coating of 350 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red leadpaint and 2 coats of enamel paint. |
| 50 | Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners,supports, nut bolts etc. complete with compliance to IS |
| 51 | Wiring for plug on board with Switch socketsurface/concealed type, copperwiring and earthing and with modular accessories as per specification No: WG |
| 52 | Supplying and erecting regular/ standard model ceiling fan of 900 /1050 mm. sweep complete erected in position asper specification no. FG-FN/CF |
| 53 | Supplying, erecting and marking double pole isolator only switch version of miniature circuit breaker of 40A with required wiring connections and lugs etc. in provideddistribution board. |
| 54 | Providing and managing 20 Trees in the same premises under Management strategies and implementation Plan (MSIP) to Manage Environment Social Health and safety |