| 1 | Demolition ofPCC in Ground Floor and paving n exc 15 cm (below or above ground level) |
| 2 | Dismantling structural steel works including steel work in doors, gates, framed truss etc complete all as specified and as directed. |
| 3 | Dismantaling Stone slabs and tiles of any description or thickness in floors, aprons etc. |
| 4 | M&L for coloured Glazed ceramic tiles invertical surface 350x 250x 7mm/ 450X 350X 7mm thickset and jointed in neat cement slurry and pointed in white or colour cement to match in white or coloured cement to match over 10 mm backing coat in CM1:3 including complete all as specified and directed. |
| 5 | M&L 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like over20mm cement mortar screed 1:3 including pointing in white cementusing marble dust with admixture of pigment to match with shade of granite.and black |
| 6 | M&L for 5cm sand stone slabs in sunshades, chajjas, shelves, cills, landings, cover stones, templates etc, n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:2 or cement mortar 1:4, complete complete all as specified and as directed by the Engineer-in-Charge |
| 7 | M&L for 75 mm thick PCC 1:3:6 type C2 (using 40 mm graded crushed stone aggregates) as in plinth protection finished even and smooth all as specified. |
| 8 | Complete removal of existing water proofing treatment incl bedding if any n exc. 50mm thick etc. on any type of roof, cleaning with wire brushers etc. and removal of debris out side MD land complete all as specified and directed. |
| 9 | Dismantling Stone slabs in roofs, suspended floors , chajjas, landings, etc., any thickness, jointed in any mortarcomplete all as specified and as directed by the Engineer-in-Charge. |
| 10 | M&L forJodhpur stone roof slabs, self faced10cm thick, 25cm to 35cm wide, hoisted and set, jointed and set in cement mortar 1:3complete all as specified and as directed by the Engineer-in-Charge |
| 11 | M&L forJodhpur stone roof slabs, self faced10cm thick, 25cm to 35cm wide, hoisted and set, jointed and set in cement mortar 1:3complete allas specified and as directed by the Engineer-in-Charge but Except stone slabs |
| 12 | M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate for levelling course for consolidated thickness shall be varied from 40 mm as per the requirements all as directed by Engr-in-Charge. |
| 13 | M&L for 10mm thick screed plaster on roof for laying in CM 1:4 waterproofing treatment, with using WPC (WPC will be measured and paid separately as supply only) |
| 14 | Supply only integral Waterproofing compound. |
| 15 | M&L for APP based polymeric membrane minimum weighing 3 Kg/Sqm and minimum 3mm thick reinforced with polyester non wove fabric (wt not less than 150 gms/sqm) laid over primed surface including bituminous primer conforming to IS-3384 applied @ 0.3 Ltr/Sqm by forced and sealing all the over laps of 75 mm in length side and 100 mm on the width side of membrane all as speficied and directed. |
| 16 | Taking down cement plaster on walls and roof ceilings etc., including racking out joints, hacking for key, scrubbing down with water etc. to receive new plaster |
| 17 | M&L rendering 15mm thick in 1:6 cement plaster on stone masonary surface is to be finished even and smooth (without using extra cement) complete all as specified and directed. |
| 18 | M & L for Cement plastering 15mm( thick in two layers -first layer 10mm thick with ready mix plaster and outer layer 5mm thick ready mix water proof plaster) on outer walls by adding potable water by weight of material as mentioned by manufacture ready mix plaster shall comply with IS- 1661-1972, IS-2402-1963, IS- 2250-1981 and shall confirm 28 days compressive strength 10-15 MPA, bulk density 1600-1800 kg/M and pull out bond strength->0.5 MPA complete all as specified and directed |
| 19 | M & L forrendering 10mm thick ready mix plaster on internal wall by adding potable water by weight of material as mentioned by manufacture ready mix plaster shall comply with IS- 1661-1972, IS-2402-1963, IS-2250-1981 and shall confirm 28 compressive days cstrength 10-15 MPA bulk dencity 1600-1800 kg/cum and pull out bond strength-> 0.5 MPA omplete all as specified and directed. |
| 20 | M & L forrendering 5 mm thick ready mix self curingplaster on ceilling by adding potable water by weight of material as mentioned by manufacture ready mix plaster shall comply with IS- 1661-1972, IS-2402-1963, IS-2250-1981 and shall confirm 28 compressive days cstrength 10-15 MPA bulk dencity 1600-1800 kg/cum and pull out bond strength-> 0.5 MPA omplete all as specified and directed. |
| 21 | M&L preparation of new wall surface and applying two coats of distemper oil emulsion over a coat of alkali resistant primer,including 1.5 to 2 thick wall care putty on wallcomplete all as specified and directeded. |
| 22 | M&L preparation of new wall surface and applying three coat of white wash on surfaces of ceiling complete all as specified & directed by Engineer-in-charge. |
| 23 | Finishing wall with Acrylic emulsion smooth exterior paint of reqd shade, new work (two or more coat) applied @ 1.67 Ltr/10 Sqm over and incl priming coat of exterior primer applied @ 2.20 Kg/10 Sqm complete. |
| 24 | Taking down Chowkat or frames with shutters (with out taking off shutters fromthe frames) area n exc. 1.50 Sqm each and removing to store |
| 25 | Taking down Chowkat or frames with shutters (with out taking off shutters fromthe frames) area exc 1.50 sqmand n exc 4.00 sqm |
| 26 | Second class HW rail and style plain frame factory made moulded panelled shutter 35 mm thick (two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered partical board with commercial veeneering on both faces. The size of rail and stile as per IS: 1003 (Part-I), kiln seasoned and chemically pressure treated. |
| 27 | S&F Factory made Box Type steel window with side hung shutters including projecting type hinges with steel handle, and steel peg stay , complete without glazing bars, dovetailed or complete as shown in Drawing No. CEJZ/TD/22 sh 1/1 to 1/3, and all as specified & directed by Engineer-in-Charge. |
| 28 | S&F Factory made Box Type steel window with side hung shutters including projecting type hinges with steel handle, and steel peg stay , complete with glazing bars, dovetailed or complete as shown in Drawing No. CEJZ/TD/22 sh 1/1 to 1/3, and all as specified & directed by Engineer-in-Charge. |
| 29 | Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanksand similar work conforming to Fe Fe 290 Gde E-165 |
| 30 | Joist, channel, angle, or tee sections, fixed independently, without connection plate, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated),Fe 410-W (Gde E-250) quality A |
| 31 | Supply and fix Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples |
| 32 | S&F 4 mm thick sheetglass ordinary quality and glazingwith oilputty in squaren exc 0.50 sqn in each pane. |
| 33 | S&Fmild steelbutt hingesminimumweight 100mm size. Mild steel cold rolled as specified & directed by Engineer-in-charge. |
| 34 | S&F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised. |
| 35 | S&F Aluminium alloy , anodised sliding door bolt 300 mm long with hasp, staple ( Bolt type) and fixing clips of sheet, cast or extruded section or cast aluminium alloy and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed. |
| 36 | Preparation of new wooden surfaces of any description, nototherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and direction. |
| 37 | Preparation of new Steel surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and direction. |
| 38 | Taking up or down steel tubing and connections including cleaning for refixing or removal to store 20 mm bore to walls, ceiling etc. |
| 39 | S&F Medium grade GI tubing 20 mm bore with all fittings , to walls, ceiling or laid in floors etc. |
| 40 | S&F gun metal globe or gate valves with iron wheel head screwed both end for iron pipe and fixed in repairs to 20 mm bore pipe. |
| 41 | S&F in repairs bib taps cast cipper alloy chromoum plated fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed in repairs |
| 42 | Demolition of stone/ bouldermasonry and built in cement mortarall as specified & directed by Engineer-in-charge. |
| 43 | M&L for squared rubble walling, Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) all as specified & directed by Engineer-in-charge. |
| 44 | Extra over stone walling for hammer dressing to face stones with maximum depression on face from a straight edge not exceeding 20mm & dressing face beds and joints as specified to squared rubble walling Jodhpur type brought up to courses all as specified & directed by Engineer-in-Charge. |
| 45 | M&L for 75mm thick PCC 1:4:8type D-2 (40 mm graded stone aggregate) |
| 46 | M&L 25 mm thick of sand layer under interlocking paver block. |
| 47 | M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade With Grey Cement and no pigment all as directed and specified. |
| 48 | M&L red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering |
| 49 | Taking down carefully existing point wiring of any description light, fan,sockets,bells etc) complete including fittings such as terminal boxes, switches, sockets, ceiling rose, lamp holders, brackets sketch fittings, pendants, fan regulartors and making good the disturbed surfaces, walls, floors etc. all as directed by EIC |
| 50 | Taking down old unsv MCB DB / main switch incl MCBs / MCCBs complete all as specified and directed |
| 51 | M&L point wiring complete with 4 Sqmm single core PVC insulated cable 1100 Volts grade multistranded copper conductor drawn through in PVC Casing and Capping on surface stone/brick, masonry walls, roofs floors etc including MS terminal boxes fabricaterd out of 1.12mm thick MS sheet sunk type / surface type and laminated top sheet of 2mm thick for housing switches sockets, regulators etc including provn of 4 sqmm dia copper conductor for earth wire continuity for 3 pin 15/16 Amps switch socket combination all as specified and directed by Engineer-in-Charge |
| 52 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspen ded by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular of size 10 sqmm complete. |
| 53 | S&F Sheet Modular metal enclosure DB SPN 240 Volts 8 Way single door type with 200 Amps busbar for fixing of MCBs |
| 54 | S&F MCB Single pole and neutral, 40A, 240 Volts AC all as specified |
| 55 | S&F MCB Single pole, 5-32A,240 Volts AC all as specified |
| 56 | Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB |