}

Tender For Construction Of E- Library Room In Village Chowki Khwajpur . Wc-06 - Earth Work In Excavation By Mechnical Means (Hydraulic Excavation) Manual Means In Foundation Trenches Or Drain (Not Exceeding 1.5 M In Width) Or 10 Sqm On Plain Including Dr, Gautam Buddha Nagar-Uttar Pradesh

Tender Notice

51868672
Tender For Construction Of E- Library Room In Village Chowki Khwajpur . Wc-06 - Earth Work In Excavation By Mechnical Means (Hydraulic Excavation) Manual Means In Foundation Trenches Or Drain (Not Exceeding 1.5 M In Width) Or 10 Sqm On Plain Including Dr
Tender
Indian
Uttar Pradesh
Gautam Buddha Nagar
27-10-2025

Tender Details

Tender For Construction Of E- Library Room In Village Chowki Khwajpur . Wc-06 - Earth work in excavation by mechnical means (hydraulic excavation) manual means in foundation trenches or drain (not exceeding 1.5 m in width) or 10 Sqm on plain including dressing of sides remaining bottom, lift upto1.5 m including getting out the excavated earth and disposal of surplus excavated soil as per direction of engg. in charge with in lead upto 50 m DAR 2.8.1 2 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%. (DAR/2.34.1/Based on UPPWD/SOR-2020)) 3 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration (DAR/2.35.3.1/Based on UPPWD/SOR-2020) 4 2.5 cm thick Damp Proof Course with Cement and approved coarse sand 1:1½ with and including water proofing as ordered by the Engineer incharge in the proportion as specified by the manufacturer including supply of all materials, labour, Tools & plants etc. required for proper completion of the work and including proper curing & shutterings as necessary. (UPPWD/SOR-2020/361) 5 providing applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. (DAR/4.13/Based on UPPWD/SOR-2020)) 6 Cement concrete with 4cm Guage Approved Stone ballast , Coarse Sand& Cement in the proportion of 8:4:1 including Supply of all material, Labour, Tools & Plants etc required for Proper completion of the work. UPPWD/SOR/281/P-17 7 M-150 brick work in 1:4 cement and Coarse sandmortar in foundation and plinth including supply of all material, labour and tools and plants. ect. required for proper completion of work .UPPWD/SOR/303+(305) 8 M-150 brick work in 1:4 one cement and four course sand 2.20 F.M. mortar superstructureincluding supply of all material, labour, T&P etc. required for proper completion of the work. (UPPWD/SOR-2020/305(a)+310 9 M-150 brick work in 1:4 one cement and four course sand 2.20 F.M. mortar superstructure but for wall of half brick thickincluding supply of all material, labour, T&P etc. required for proper completion of the work. (UPPWD/SOR-2020/305(a)+310a 10 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.(DAR-18/6.15/Based on UPPWD/SOR-2020) 11 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All works upto plinth level. (DAR-18/5.33.1/Based on UPPWD/SOR-2020) 12 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).All works above plinth level upto floor V level. (DAR-18/5.33.1/Based on UPPWD/SOR-2020) 13 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 14 Foundations, footings, bases of columns, etc. for mass concrete. (DAR/5.9.1/Based on UPPWD/SOR-2020)) 15 Lintels, beams, plinth beams, girders, bressumers and cantilevers. (DAR/5.9.5/Based on UPPWD/SOR-2020)) 16 Columns, Pillars, Piers, Abutments, Posts and Struts. (DAR/5.9.6/Based on UPPWD/SOR-2020)) 17 Suspended floors, roofs, landings, balconies and access platform (DAR/5.9.3/Based on UPPWD/SOR-2020)) 18 Edges of slabs and breaks in floors and walls:Under 20 cms wide. (DAR/5.9.16.1/Based on UPPWD/SOR-2020) 19 Earth work in cutting or embankment in ordinary soil excavation to be in the form of regular pits not exceeding 0.50M in depth and earth work in embankment to be in 20cm. layers including rernming and dressing the surface to required levels and slopes and also including 1.50M lift and 30M lead. The earth from cutting to be used in making embankment or to be depoiseted as spoil banks with in 30M distance as directed by yhe Engineer incharge.Excluding Royality. Wherever applicable for small work or Abadi area. (Only for where machine can not be reach/Move) SORUPPWD/253A+231A/P-14 20 Steel rainforcement for R.C.C. work including straightening, cutting bending, placing in position and binding all complete upto plinth level. Thermo-mechanically treated bars/Cold twisted bars. (DAR/5.22.6/Based on UPPWD/SOR-2020) 21 12 mm cement plaster of mix : 1:6 (1cement :6 coarse sand)(DAR/13.4.2/Based on UPPWD/SOR-2020)) 22 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) (DAR/13.16.1/Based on UPPWD/SOR-2020)) 23 15 mm cement plaster on rough side of single : 1:6 (1 cement: 4 coarse sand) (DAR/13.5.2/Based on UPPWD/SOR-2020)) 24 Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied 3.84 kg/b sqm). (Based on UPPWD/SOR-2020/P-39) 25 Distempering (first coat) with oil bound distemper of approved brand and manufacture and of required shade on undecorated wall surface to give an even shade over and including a priming coat with cement primer of approved brand and manufacture such as Berger, J&N, Shalimar, Asian Paint after thoroughly brushing the surface free from mortar dropping and other foreign matters andalso including the surface even with plaster of Paris or approved synthetic materials and sand papered smooth including supply of all materials, labour,Tools & plants etc.required for proper completion of the work. (but for every coat after the first coat). (UPPWD/SOR-2020/649+650)P-22 26 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. SOR-2020/P-23/New Item 27 Painting with synthetic enemel paint of approved brand and manufacture to give an even shade:Two or more coats on new work.UP PWD SOR 2020/13.61.1 28 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110mm diameter (DAR/12.41.2/Based on UPPWD/SOR-2020)) 29 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion: 30 Single tee with door 110x110x110 mm. (DAR/12.42.3.2/Based on UPPWD/SOR-2020) 31 110 mm bend. (DAR/12.42.5.2/Based on UPPWD/SOR-2020) 32 110 mm Shoe. (DAR/12.42.6.2/Based on UPPWD/SOR-2020) 33 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 10 mm.(DAR/12.43.2/Based on UPPWD/SOR-2020 34 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. (DAR/12.44/Based on UPPWD/SOR-2020 35 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. UP PWD SOR 2020/DAR-18/10.25.2 36 Providing and fixing water closet squatting pan (Indian type W.C. pan with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests. UP PWD SOR 2020/DAR-18/17.1.1 37 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. (DAR/18.17.1/Based on UPPWD/SOR-2020) 38 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge 39 20mm OD pipes. (DAR/18.8.2/Based on UPPWD/SOR-2020) 40 25mm OD pipes. (DAR/18.8.3/Based on UPPWD/SOR-2020) 41 Providing and fixingbrass gate valve with C.I. wheel of approved quality (screwed end) : 42 25 mm nominal bore. (DAR/18.17.1/Based on UPPWD/SOR-2020) 43 32 mm nominal bore. (DAR/18.17.2/Based on UPPWD/SOR-2020) 44 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls up to 300 mm height including cleaning the surface before treatment.b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand)admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with waterproofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d)Finishing the surface with 20 mm thick joint less cement mortar of mix1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120mm and minimum thickness at khurra as 65 mm. (DAR/22.7.1/Based on UPPWD/SOR-2020) 45 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (DAR/18.48/Based on UPPWD/SOR-2020) 46 Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.(DAR/4.17/Based on UPPWD/SOR-2020)) 47 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600mm (DAR/11.41.2/Based on UPPWD/SOR-2020)) 48 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (DAR/8.31/Based on UPPWD/SOR-2020)) 49 Providing and fixing brass bib cock of approved quality : 15 mm nominal bore.(DAR/18.15.1/Based on UPPWD/SOR-2020) 50 Providing and fixingbrass gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore. (DAR/18.17.1/Based on UPPWD/SOR-2020) 51 Providing and fixing nahani trap 75x100mmincluding all complete. 52 20 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand. (DAR/13.6.1/Based on UPPWD/SOR-2020) 53 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 30mm thick including ISI marked stainless steel butt hinges with necessary screws. (DAR/9.21.2/Based on UPPWD/SOR-2020)) 54 Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. (Shutter area to be measured). (DAR/9.14/Based on UPPWD/SOR-2020)) 55 Renewing panes of glass in door, window & ventilators or fixing in the new work with 3mm thick glass panes fixed with brads & putty includung supply of all material , labour , tools & plants required for proper completion of work. UPPWD SOR 2020/P26/806 56 Providing and fixing ISI Mark 3 layer prelaminated particle board conforming to grade 2 type-III of IS-12823/20B laminated with 0.6-0.8 mm thick laminate conforming to IS-2046/1995 and balancing lamination of 0.5 mm thick on the back side (size 700*750*430) including all complete. M/R 57 Supply of work SB collection office/visitor chain with sheat DXWXH 400*400*450 mm padded with polyurithane foam complete. M/R 58 Supply wook at site SB collection executive table of 3 layer Prelaminated particle board (wood product) of grade 2 type 2 of IS-12823/latest 1830 mm 950 mm 750mm including all complete 59 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 Kms. from the site of work and including watering, dressing etc. labour and T&P etc. required for the proper complition of the work.saplings of girth upto 30 cms. measured at a height of 1 M. above ground level and removal of rubbish upto a of cleared.50 M. out side the periphery of area distance (UPPWD/SOR-2020/255) 60 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) (DAR/10.11.1/Based on UPPWD/SOR-2020) 61 Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 150. (DAR/19.27.1/Based on UPPWD/SOR-2020) 62 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. (DAR/19.1.1/Based on UPPWD/SOR-2020) 63 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design. (DAR/19.2.1/Based on UPPWD/SOR-2020) 64 Providing and fixing square-mouth S.W. gully trap class SP-1 complete withC.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. (DAR/19.4.1/Based on UPPWD/SOR-2020) 65 Providing and fixing Heavy Class SS gratingof approved design including setting in floor with cement motor to match with floor finish as per architect requirement suitable for waster and FT, UT & FD. Size 150 mm X 150 mm. M/R 66 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.(DAR/17.73.2/Based on UPPWD/SOR-2020)) 67 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (DAR/17.31/Based on UPPWD/SOR-2020) 68 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. (DAR/18.65/Based on UPPWD/SOR-2020) 69 Providing and fixing chicken wire mesh (murga jali) 24 gauge and 20 mesh at junction of RCC and masonry walls including fixing in position with steel nails of 25 mm in length as approved at required as directed by Engineer-in-charge, scaffolding etc. complete ½x24 gauge (AR/YEIDA//Based on UPPWD/SOR-2020)) 70 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper (DAR/9.101.1/Based on UPPWD/SOR-2020)) 71 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :250x10mm (DAR/9.97.2/Based on UPPWD/SOR-2020)) 72 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm (DAR/9.100.1/Based on UPPWD/SOR-2020)) 73 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 25mm nominal bore, weighing not less than 62 gms. (DAR/18.75.3/Based on UPPWD/SOR-2020) 74 Providing & Fixing of CP Heavy Duty Bottle Trap 32mm. (Complete complying with relavent standard specification and as directed by the Competent authority.) For Wash basin&Urinal. (DAR/17.70.1/Based on UPPWD/SOR-2020) 75 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6mm for diagonal braces and central cross piece. (DAR/10.5.2/Based on UPPWD/SOR-2020) 76 Construction of Granular Sub-Base by providing close graded material, mixing in mechanical mix plant at OMC, carriage of mixed material to work at site, spreading uniform layers with motor grader on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 for Grade-1 material. (MORTH/(AR/YEIDA/Based on UPPWD/SOR-2020) 77 Providing and laying 60mm thick I.S.I. mark factory made cement concrete interlocking concrete paver block made by block making machine with strong vibratory compaction of approved size, design, shape, laid in required colour and pattern over and including average 50mm thick compacted bed coarse sand and filling the joints with fine sand all complete as per the direction of Engineer-in-charge with conforming to IS-15658 and IRC:SP:63. (AR/YEIDA/ Based on UPPWD/SOR-2020) 78 Electrical Work:- 79 Wiring point for light in 1.5 sq. mm. PVCinsulated singlecorecopperconductor cable (inPVCconduit with 1.5sq.mm. FRLSH PVC insulated multistrand copperconductor cable as earth wire drawn inside conduit.)and5 Amp.flush typeswitch& ceiling rose/angle/batten holderfixedwith3mmthickphenolic laminate backalitesheet withbrass machinescrews andcup washers mounted overexisting M.S.switch boardbox/junction boxwith supplyofallmaterial, labour& T&P etc. requiredforproper completion of the work complete in all respect, as directed by Engineer in charge PWD-2018 PS No-174C 80 Supply and Wiring of submains with 2 nos. of 2.5 sq. mm. FRLSH PVC insulated1100 Vgrade multistrand singlecore copper conductorcable in 25mm dia heavy duty (2mm thick) PVC conduitwith2 nos 2.5 sq.mm.FRLSH PVC insulated multistrand copperconductor cable asearth continuity wire drawn in conduit complete in all respect, as directed by Engineer in charge PWD-2018 PS No-261C 81 Supply and fixing of power plug with 20 Amp./250 voltflush type modularswitchand 5 pin 20 A/250 voltflush typeuniversal modular socket switch on concealed M.Sboxincluding supply of allmaterial, labourT&Petc. complete in all respect, as directed by Engineer in charge .PWD-2018 PS No-1139A 82 S&F surface/flush mounting 8 ways SPN distribution board with additional metal door without MCB complete in all respect, as directed by Engineer in charge. PWD-2018 PS -1024A 83 S&F of 6 Amp to 32 Amp. MCB (10 KA) C Curve complete in all respect, as directed by Engineer in charge.PWD-2018PS -1002CAT-A 84 S&F of 40Amp. DP MCB (10 KA) C Curve complete in all respect, as directed by Engineer in charge. PWD-2018 PS No-1010 Cat-A 85 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. (DAR/10.18/Based on UPPWD/SOR-2020))

Key Value

Document Fees
INR 920 /-
Tender Value
INR 32.33 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail