Tender For Repairing Of Electrical Work In Kitchen And Dining Hall At Jnv Saran (Bihar) - Structural Repair & Retrofitting 2 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 3 50mm average thickness 4 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 5 Bars upto 12 mm diameter 6 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 7 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 8 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 9 50mm thick in Grade M 25 with cement content not less than 330 kg per cum 10 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 11 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 12 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 13 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 14 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. 15 With cement mortar 1:4 (1cement: 4 coarse sand) 16 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 17 12mm cement plaster of mix : 18 1:6 (1 cement : 6 course sand) 19 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 20 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 21 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 22 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 23 Two coats 24 Finishing walls with Premium Acrylic Smooth exterior paint withSilicone additives of required shade 25 Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm)over existing cement paint surface 26 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 Old work (one or more coats) 27 Old work (one or more coats) 28 Repairs to Door / Windows 29 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 30 Of area 3 sq. metres and below 31 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 32 Of area 3 sq. metres and below 33 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 34 Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) 35 Renewal of old putty of glass panes (length) 36 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete 37 Fixed to steel windows by welding 38 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 39 300 mm weighing not less than 200gms. 40 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 41 With 12 mm mild steel U beading 42 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 43 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 44 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 45 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 46 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 47 4.0 mm thick glass panes 48 Applying priming coat : 49 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 50 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 51 Two or more coats on new work 52 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 53 One or more coats on old work 54 Miscellaneous 55 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 56 In cement mortar 57 Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 58 Repairs to Internal Wiring and Fans / Light Fittings 59 SWITCH CONTROL LIGHT POINTS 60 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 61 Group C 62 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without Independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. (Switch Control Secondary Points) 63 Group C 64 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points) 65 Group C 66 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (withoutIndependent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. (Switch Control Secondary Points) 67 Group C 68 MCB CONTROL LIGHT POINTS 69 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points) 70 Primary point controlled by one MCB. 71 Same as item above but Secondary point. i.e. Points to be looped with Primary pointwith 2.5 sqmm wire and Point wiring 72 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 73 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 74 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 75 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 76 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 77 2 x 10 sq. mm + 1 x 10 sq.mm earth wire 78 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 79 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 80 Supplying and fixingsuitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing3 pin 5/6 Amp modular socket outlet and 5/6 A modular switch, connection etc. as required. 81 Supply and Wiringfor 250 volts singlephase and neutral 2 Nos 6 amps socket outlate with control by 1 No switched with 2.5 sq.mm PVCinsulatedcopper conductor1100 volts grade stranded flexible FRLS wires inconcealed or surface mounted 25 mm dia 2mm thickPVC conduit including providing and fixing of 6 amps 3 pin switch socket outlet of aprpoved make and design in 2 mm thick GI box with grid plate and earthingofthird pin of the socket with2.5Sq. mm PVC insulated copper conductor strandedflexibleFRLSwire.(maximum four no. of switches socket shall be connected on onecircuit) 82 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 83 Supplying and fixing 63 A, 415 V, TPN Industrial type socketoutlet, with 4 pole and earth, metal enclosed plug topalongwith 63 A C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. 84 Supplying and fixing 80 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 80 A C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. 85 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 86 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, “C” curve including connection, painting etc. as required. (ACs & Gysers) 87 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 88 25 mm 89 32 mm 90 Supply, Installation, Testing and Commissioning of 18W Surface/Recessed Mounted LED circular Downlighter. 91 Supply, Installation, Testing and Commissioning of 18/20W Wall/Surface mouted 4 ft. LED 92 Supply, Installation, Testing and Commissioning of 15WSurface mountedLED Square Downlighter. 93 Supply, Installation, Testing and Commissioning of 12/9WRecessed mountedLED circular Downlighter. 94 Supply, Installation, Testing and Commissioning of9W (Nominal)Wall Bracket Light 95 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 96 SupplyInstallation, Testing and Commissioning of 250 mm dia Domestic Exhaust Fan 97 Supplyingand fixingoffollowingwayssurface/recessmounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note :Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 98 12 way (4 + 36), Double door 99 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 Single Pole 101 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 102 63 A 103 Supplying and fixing following rating, double pole, (single phaseand neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 104 63 A 105 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 106 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 107 Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required. 108 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 109 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) 110 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 111 Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 112 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. 113 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Details of cost for one Set 114 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 115 Supply, installation, testing and commissioning of M.V. cubical type totally enclosed dust, dump and vermin proof Meter Bords complete with bus bars, MV danger notice plate, on surface ISI marked Electronic kWh meter, indication lamps, CTs, Interconnection with suitable capacity aluminium strips / rods, door covers, seperate compartment for each meter, glass inspection window, connection of incoming and outgoing cables with thimbles, powder coated having following incoming and outgoingMCBs MCCBs and kWh meters complete as required. 116 PANEL -K&D 117 INCOMER 118 1 No.63 Amp FP MCCB, 15 kA breaking capacity with thermal release and adjustable setting and with rotary handle. 119 METERING & INDICATION 120 1 set of R,Y,B phase indicating lamps 121 Digital Multifunction meter for Voltage, Current & KW with selector switch. Each with 3nos. of 2A SP MCB & 3nos 63/5A CTs (63A/500V) rating 122 1 Sets of Breaker ON-OFF-TRIP, Spring charged indication Lamps as required. 123 BUS-BAR 124 1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves 125 OUT GOING: 126 4 Nos. 40A TPN MCB of 10kA 127 3 No. 40A DP MCB of 10kA. 128 Supplying,Receiving, fixing, testing & commissioning ofabove described Panel